Compare commits

..

17 Commits

Author SHA1 Message Date
Jean-Marc Collin
9e52c843bc Issue-739-refactor-to-modularize (#742)
* Refactor Presence Feature

* Add PresenceFeatureManager ok

* Python 3.13

* Fix presence test

* Refactor power feature

* Add Motion manager. All tests ok

* Tests ok. But tests are not complete

* All tests Window Feature Manager ok.

* All windows tests ok

* Fix all testus with feature_window_manager ok

* Add test_auto_start_stop feature manager. All tests ok

* Add safety feature_safety_manager
Rename config attribute from security_ to safety_

* Documentation and release

* Add safety manager direct tests

* Typo

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2025-01-01 16:30:18 +01:00
Romain Van Vooren
d2a94d33e8 Add installation link (#762) 2024-12-31 19:35:26 +01:00
Jean-Marc Collin
6e5e304b71 issue #713 - config_entry is deprecated (#738)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-12-22 17:20:15 +01:00
Jean-Marc Collin
8559dd144a issue #733 - VTherm over_climate not following TRV device setpoint when step if < 1 (#736)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-12-22 16:14:33 +01:00
Jean-Marc Collin
65b4690e64 issue #683 - incorrect temperature reversion on window close (#734)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-12-22 15:49:46 +01:00
Jean-Marc Collin
6c5ddc315c Add troubleshooting documentation on VTherm doesn't follow 2024-12-22 09:46:14 +00:00
Jean-Marc Collin
081a2351de Issue #690 - VTherm don't follow underlying change with lastSeen activated (#732)
* Issue #690 - VTherm don't follow underlying change with lastSeen activated

* Fix tests warnings

* Add a lastSeen test

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-12-22 10:40:35 +01:00
Jean-Marc Collin
d9791f6cb0 Feature #722 minimum valve opening (#731)
* ok + testu ok

* Feature #722 - Add a minimum opening degree for valve regulation

* Feature #722 - Add a minimum opening degree for valve regulation

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-12-21 19:41:12 +01:00
Jean-Marc Collin
24f6445861 Revert "ok + testu ok (#729)" (#730)
This reverts commit 083a3a4c81.
2024-12-21 19:31:35 +01:00
Jean-Marc Collin
083a3a4c81 ok + testu ok (#729)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-12-21 19:29:35 +01:00
Jean-Marc Collin
ee42a235c0 Issue #698 nb device active for boiler not updating (#728)
* With tests and list of active

* Issue #698 - nb nb_device_active_for_boiler don't work for climate without hvac_action

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-12-21 17:24:24 +01:00
Sebastian Noe
9839ed4920 Add attribute with active underlyings for easier tracking and setup (#658)
* Add attribute with active underlyings for easier tracking and setup

* Issue #645   add sonoff trvzb (#651)

* With Sonoff configuration ok

* Fix configuration

* Next (not finished)

* With 1rst implementation of VTherm TRVZB and underlying

* Work in simuated environment

* Fix Testus

* Release

* Fix release name

* Add #602 - implement a max_on_percent setting

* Calculate offset_calibration as room_temp - local_temp
Fix hvac_action calculation

* Fix hvac_action
Fix offset_calibration=room_temp - (local_temp - current_offset)

* Fix underlying target is not updated

* Issue #655 - combine motion and presence

* Fix Valve testus. Improve sending the open percent to valve

* Update custom_components/versatile_thermostat/translations/en.json

Co-authored-by: Alexander Dransfield <2844540+alexdrans@users.noreply.github.com>

* Indus step1

* Step 2 - renaming. All tests ok

* Step 2: manual tests ok

* First unit test ok

* Test multi ok

* All tests ok. Add a multi test for climate with valve regulation

* With testu for config_flow ok

* Documentation (not finished)

* Fix #661 - central boiler doesn't starts with Sonoff TRVZB

* Remove // testing

* Fix exception when there is no offset at all

* Fix class attributes and instance attributes mixing

* Documentation 2

* Documentation 3

* Documentation ++

* documentation

* Try to fix the central boiler calculation

* Fix #669

* Documentation ++

* Documentation ok for FR

* Readme FR|EN

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
Co-authored-by: Alexander Dransfield <2844540+alexdrans@users.noreply.github.com>

* Documentation rework

* En links

* Documentation issue #650

---------

Co-authored-by: Sebastian Noe <sebastian.schneider@boxine.de>
Co-authored-by: Jean-Marc Collin <jm.collin.78@gmail.com>
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
Co-authored-by: Alexander Dransfield <2844540+alexdrans@users.noreply.github.com>
2024-12-21 09:36:46 +01:00
Jean-Marc Collin
02f60770e8 Try to fix issue #702 2024-12-21 08:28:13 +00:00
Edwin ten Haaf
23ddff95b3 fix for 'It's not possible to set regulation mode to Expert using Automations' (#718)
Co-authored-by: Edwin ten Haaf <edwin.ten.haaf@rawworks.nl>
2024-12-20 08:41:16 +01:00
Jean-Marc Collin
53160f1365 issue #702 - migrate to HA 2024.12 (#708)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-12-14 11:56:36 +01:00
Jean-Marc Collin
1aaa6d4461 Issue #696 follow underlying doesn't work anymore (#701)
* Issue #696 - follow underlying doesn't work anymore

* Fix testu

* Release

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-12-11 08:21:26 +01:00
Jean-Marc Collin
a09af6a184 Remove erreur messages component.versatile_thermostat.options.step.menu.title failed: ({'name'} != set()) 2024-12-10 16:45:58 +00:00
87 changed files with 6189 additions and 2539 deletions

View File

@@ -1,2 +1,2 @@
FROM mcr.microsoft.com/devcontainers/python:1-3.12
RUN apt update && apt install -y ffmpeg
FROM mcr.microsoft.com/devcontainers/python:1-3.13
RUN apt update && apt install -y ffmpeg libturbojpeg0-dev

View File

@@ -1,15 +1,13 @@
// See https://aka.ms/vscode-remote/devcontainer.json for format details.
// "image": "ghcr.io/ludeeus/devcontainer/integration:latest",
{
"build": {
"dockerfile": "Dockerfile"
},
"name": "Versatile Thermostat integration",
"appPort": [
"8123:8123"
],
// "postCreateCommand": "container install",
"postCreateCommand": "./container dev-setup",
"build": {
"dockerfile": "Dockerfile"
},
"name": "Versatile Thermostat integration",
"appPort": ["8123:8123"],
// "postCreateCommand": "container install",
"postCreateCommand": "./container dev-setup",
"mounts": [
"source=${localEnv:HOME}/.ssh,target=/home/vscode/.ssh,type=bind,consistency=cached",
@@ -17,52 +15,53 @@
"source=${localEnv:HOME}/SugarSync/Projets/home-assistant/versatile-thermostat-ui-card/dist,target=/workspaces/versatile_thermostat/config/www/community/versatile-thermostat-ui-card,type=bind,consistency=cached"
],
"customizations": {
"vscode": {
"extensions": [
"ms-python.python",
"ms-python.pylint",
// Doesn't work (crash). Default in python is to use Jedi see Settings / Python / Default Language
// "ms-python.vscode-pylance",
"ms-python.isort",
"ms-python.black-formatter",
"visualstudioexptteam.vscodeintellicode",
"redhat.vscode-yaml",
"github.vscode-pull-request-github",
"ryanluker.vscode-coverage-gutters",
"ferrierbenjamin.fold-unfold-all-icone",
"LittleFoxTeam.vscode-python-test-adapter",
"donjayamanne.githistory",
"waderyan.gitblame",
"keesschollaart.vscode-home-assistant",
"vscode.markdown-math",
"yzhang.markdown-all-in-one",
"github.vscode-github-actions",
"azuretools.vscode-docker"
],
"settings": {
"files.eol": "\n",
"editor.tabSize": 4,
"terminal.integrated.profiles.linux": {
"bash": {
"path": "bash",
"args": []
}
},
"terminal.integrated.defaultProfile.linux": "bash",
// "terminal.integrated.shell.linux": "/bin/bash",
"python.pythonPath": "/usr/bin/python3",
"python.analysis.autoSearchPaths": true,
"pylint.lintOnChange": false,
"python.formatting.provider": "black",
"python.formatting.blackPath": "/usr/local/py-utils/bin/black",
"editor.formatOnPaste": false,
"editor.formatOnSave": true,
"editor.formatOnType": true,
"files.trimTrailingWhitespace": true
// "python.experiments.optOutFrom": ["pythonTestAdapter"],
// "python.analysis.logLevel": "Trace"
}
}
}
"customizations": {
"vscode": {
"extensions": [
"ms-python.python",
"ms-python.pylint",
// Doesn't work (crash). Default in python is to use Jedi see Settings / Python / Default Language
// "ms-python.vscode-pylance",
"ms-python.isort",
"ms-python.black-formatter",
"visualstudioexptteam.vscodeintellicode",
"redhat.vscode-yaml",
"github.vscode-pull-request-github",
"ryanluker.vscode-coverage-gutters",
"ferrierbenjamin.fold-unfold-all-icone",
"LittleFoxTeam.vscode-python-test-adapter",
"donjayamanne.githistory",
"waderyan.gitblame",
"keesschollaart.vscode-home-assistant",
"vscode.markdown-math",
"yzhang.markdown-all-in-one",
"github.vscode-github-actions",
"azuretools.vscode-docker",
"huizhou.githd"
],
"settings": {
"files.eol": "\n",
"editor.tabSize": 4,
"terminal.integrated.profiles.linux": {
"bash": {
"path": "bash",
"args": []
}
},
"terminal.integrated.defaultProfile.linux": "bash",
// "terminal.integrated.shell.linux": "/bin/bash",
"python.pythonPath": "/usr/bin/python3",
"python.analysis.autoSearchPaths": true,
"pylint.lintOnChange": false,
"python.formatting.provider": "black",
"python.formatting.blackPath": "/usr/local/py-utils/bin/black",
"editor.formatOnPaste": false,
"editor.formatOnSave": true,
"editor.formatOnType": true,
"files.trimTrailingWhitespace": true
// "python.experiments.optOutFrom": ["pythonTestAdapter"],
// "python.analysis.logLevel": "Trace"
}
}
}
}

2
.devcontainer/pytest.ini Normal file
View File

@@ -0,0 +1,2 @@
[pytest]
asyncio_default_fixture_loop_scope = function

View File

@@ -69,10 +69,10 @@ motion_state: 'off'
overpowering_state: false
presence_state: 'on'
window_auto_state: false
window_bypass_state: false
security_delay_min: 2
security_min_on_percent: 0.5
security_default_on_percent: 0.1
is_window_bypass: false
safety_delay_min: 2
safety_min_on_percent: 0.5
safety_default_on_percent: 0.1
last_temperature_datetime: '2023-11-05T00:48:54.873157+01:00'
last_ext_temperature_datetime: '2023-11-05T00:48:53.240122+01:00'
security_state: true

View File

@@ -38,8 +38,9 @@ A big thank you to all my beer sponsors for their donations and encouragements.
The documentation is now divided into several pages for easier reading and searching:
1. [Introduction](documentation/en/presentation.md),
2. [Choosing a VTherm type](documentation/en/creation.md),
3. [Basic attributes](documentation/en/base-attributes.md)
2. [Installation](documentation/en/installation.md),
3. [Choosing a VTherm type](documentation/en/creation.md),
4. [Basic attributes](documentation/en/base-attributes.md)
3. [Configuring a VTherm on a `switch`](documentation/en/over-switch.md)
3. [Configuring a VTherm on a `climate`](documentation/en/over-climate.md)
3. [Configuring a VTherm on a valve](documentation/en/over-valve.md)
@@ -103,4 +104,4 @@ If you wish to contribute, please read the [contribution guidelines](CONTRIBUTIN
[license-shield]: https://img.shields.io/github/license/jmcollin78/versatile_thermostat.svg?style=for-the-badge
[maintenance-shield]: https://img.shields.io/badge/maintainer-Joakim%20Sørensen%20%40ludeeus-blue.svg?style=for-the-badge
[releases-shield]: https://img.shields.io/github/release/jmcollin78/versatile_thermostat.svg?style=for-the-badge
[releases]: https://github.com/jmcollin78/versatile_thermostat/releases
[releases]: https://github.com/jmcollin78/versatile_thermostat/releases

View File

@@ -29,6 +29,9 @@ from .const import (
CONF_AUTO_REGULATION_EXPERT,
CONF_SHORT_EMA_PARAMS,
CONF_SAFETY_MODE,
CONF_SAFETY_DELAY_MIN,
CONF_SAFETY_MIN_ON_PERCENT,
CONF_SAFETY_DEFAULT_ON_PERCENT,
CONF_THERMOSTAT_CENTRAL_CONFIG,
CONF_THERMOSTAT_TYPE,
CONF_USE_WINDOW_FEATURE,
@@ -291,6 +294,20 @@ async def async_migrate_entry(hass: HomeAssistant, config_entry: ConfigEntry):
]:
new.pop(key, None)
# Migration 2.0 to 2.1 -> rename security parameters into safety
if config_entry.version == CONFIG_VERSION and config_entry.minor_version == 0:
for key in [
"security_delay_min",
"security_min_on_percent",
"security_default_on_percent",
]:
new_key = key.replace("security_", "safety_")
old_value = config_entry.data.get(key, None)
if old_value is not None:
new[new_key] = old_value
new.pop(key, None)
hass.config_entries.async_update_entry(
config_entry,
data=new,

View File

@@ -0,0 +1,118 @@
""" A base class for all VTherm entities"""
import logging
from datetime import timedelta
from homeassistant.core import HomeAssistant, callback, Event
from homeassistant.components.climate import ClimateEntity, DOMAIN as CLIMATE_DOMAIN
from homeassistant.helpers.entity_component import EntityComponent
from homeassistant.helpers.entity import Entity
from homeassistant.helpers.device_registry import DeviceInfo, DeviceEntryType
from homeassistant.helpers.event import async_track_state_change_event, async_call_later
from .const import DOMAIN, DEVICE_MANUFACTURER
from .base_thermostat import BaseThermostat
_LOGGER = logging.getLogger(__name__)
class VersatileThermostatBaseEntity(Entity):
"""A base class for all entities"""
_my_climate: BaseThermostat
hass: HomeAssistant
_config_id: str
_device_name: str
def __init__(self, hass: HomeAssistant, config_id, device_name) -> None:
"""The CTOR"""
self.hass = hass
self._config_id = config_id
self._device_name = device_name
self._my_climate = None
self._cancel_call = None
self._attr_has_entity_name = True
@property
def should_poll(self) -> bool:
"""Do not poll for those entities"""
return False
@property
def my_climate(self) -> BaseThermostat | None:
"""Returns my climate if found"""
if not self._my_climate:
self._my_climate = self.find_my_versatile_thermostat()
if self._my_climate:
# Only the first time
self.my_climate_is_initialized()
return self._my_climate
@property
def device_info(self) -> DeviceInfo:
"""Return the device info."""
return DeviceInfo(
entry_type=DeviceEntryType.SERVICE,
identifiers={(DOMAIN, self._config_id)},
name=self._device_name,
manufacturer=DEVICE_MANUFACTURER,
model=DOMAIN,
)
def find_my_versatile_thermostat(self) -> BaseThermostat:
"""Find the underlying climate entity"""
try:
component: EntityComponent[ClimateEntity] = self.hass.data[CLIMATE_DOMAIN]
for entity in component.entities:
# _LOGGER.debug("Device_info is %s", entity.device_info)
if entity.device_info == self.device_info:
_LOGGER.debug("Found %s!", entity)
return entity
except KeyError:
pass
return None
@callback
async def async_added_to_hass(self):
"""Listen to my climate state change"""
# Check delay condition
async def try_find_climate(_):
_LOGGER.debug(
"%s - Calling VersatileThermostatBaseEntity.async_added_to_hass", self
)
mcl = self.my_climate
if mcl:
if self._cancel_call:
self._cancel_call()
self._cancel_call = None
self.async_on_remove(
async_track_state_change_event(
self.hass,
[mcl.entity_id],
self.async_my_climate_changed,
)
)
else:
_LOGGER.debug("%s - no entity to listen. Try later", self)
self._cancel_call = async_call_later(
self.hass, timedelta(seconds=1), try_find_climate
)
await try_find_climate(None)
@callback
def my_climate_is_initialized(self):
"""Called when the associated climate is initialized"""
return
@callback
async def async_my_climate_changed(
self, event: Event
): # pylint: disable=unused-argument
"""Called when my climate have change
This method aims to be overriden to take the status change
"""
return

View File

@@ -0,0 +1,58 @@
""" Implements a base Feature Manager for Versatile Thermostat """
import logging
from typing import Any
from homeassistant.core import CALLBACK_TYPE, HomeAssistant
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
from .commons import ConfigData
from .config_schema import * # pylint: disable=wildcard-import, unused-wildcard-import
_LOGGER = logging.getLogger(__name__)
class BaseFeatureManager:
"""A base class for all feature"""
def __init__(self, vtherm: Any, hass: HomeAssistant):
"""Init of a featureManager"""
self._vtherm = vtherm
self._name = vtherm.name
self._active_listener: list[CALLBACK_TYPE] = []
self._hass = hass
def post_init(self, entry_infos: ConfigData):
"""Initialize the attributes of the FeatureManager"""
raise NotImplementedError()
def start_listening(self):
"""Start listening the underlying entity"""
raise NotImplementedError()
def stop_listening(self) -> bool:
"""stop listening to the sensor"""
while self._active_listener:
self._active_listener.pop()()
self._active_listener = []
def add_listener(self, func: CALLBACK_TYPE) -> None:
"""Add a listener to the list of active listener"""
self._active_listener.append(func)
@property
def is_configured(self) -> bool:
"""True if the FeatureManager is fully configured"""
raise NotImplementedError()
@property
def name(self) -> str:
"""The name"""
return self._name
@property
def hass(self) -> HomeAssistant:
"""The HA instance"""
return self._hass

File diff suppressed because it is too large Load Diff

View File

@@ -25,10 +25,8 @@ from homeassistant.config_entries import ConfigEntry
from homeassistant.helpers.entity_platform import AddEntitiesCallback
from .vtherm_api import VersatileThermostatAPI
from .commons import (
VersatileThermostatBaseEntity,
check_and_extract_service_configuration,
)
from .commons import check_and_extract_service_configuration
from .base_entity import VersatileThermostatBaseEntity
from .const import (
DOMAIN,
DEVICE_MANUFACTURER,
@@ -111,7 +109,7 @@ class SecurityBinarySensor(VersatileThermostatBaseEntity, BinarySensorEntity):
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
old_state = self._attr_is_on
self._attr_is_on = self.my_climate.security_state is True
self._attr_is_on = self.my_climate.safety_manager.is_safety_detected
if old_state != self._attr_is_on:
self.async_write_ha_state()
return
@@ -150,7 +148,7 @@ class OverpoweringBinarySensor(VersatileThermostatBaseEntity, BinarySensorEntity
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
old_state = self._attr_is_on
self._attr_is_on = self.my_climate.overpowering_state is True
self._attr_is_on = self.my_climate.overpowering_state is STATE_ON
if old_state != self._attr_is_on:
self.async_write_ha_state()
return
@@ -319,8 +317,8 @@ class WindowByPassBinarySensor(VersatileThermostatBaseEntity, BinarySensorEntity
"""Called when my climate have change"""
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
old_state = self._attr_is_on
if self.my_climate.window_bypass_state in [True, False]:
self._attr_is_on = self.my_climate.window_bypass_state
if self.my_climate.is_window_bypass in [True, False]:
self._attr_is_on = self.my_climate.is_window_bypass
if old_state != self._attr_is_on:
self.async_write_ha_state()
return

View File

@@ -97,13 +97,13 @@ async def async_setup_entry(
)
platform.async_register_entity_service(
SERVICE_SET_SECURITY,
SERVICE_SET_SAFETY,
{
vol.Optional("delay_min"): cv.positive_int,
vol.Optional("min_on_percent"): vol.Coerce(float),
vol.Optional("default_on_percent"): vol.Coerce(float),
},
"service_set_security",
"SERVICE_SET_SAFETY",
)
platform.async_register_entity_service(
@@ -118,7 +118,7 @@ async def async_setup_entry(
SERVICE_SET_AUTO_REGULATION_MODE,
{
vol.Required("auto_regulation_mode"): vol.In(
["None", "Light", "Medium", "Strong", "Slow"]
["None", "Light", "Medium", "Strong", "Slow", "Expert"]
),
},
"service_set_auto_regulation_mode",

View File

@@ -3,17 +3,14 @@
# pylint: disable=line-too-long
import logging
from datetime import timedelta
from homeassistant.core import HomeAssistant, callback, Event
from homeassistant.components.climate import ClimateEntity, DOMAIN as CLIMATE_DOMAIN
from homeassistant.helpers.entity_component import EntityComponent
from homeassistant.helpers.entity import Entity
from homeassistant.helpers.device_registry import DeviceInfo, DeviceEntryType
from homeassistant.helpers.event import async_track_state_change_event, async_call_later
from types import MappingProxyType
from typing import Any, TypeVar
from .const import ServiceConfigurationError
from .underlyings import UnderlyingEntity
from .base_thermostat import BaseThermostat
from .const import DOMAIN, DEVICE_MANUFACTURER, ServiceConfigurationError
ConfigData = MappingProxyType[str, Any]
T = TypeVar("T", bound=UnderlyingEntity)
_LOGGER = logging.getLogger(__name__)
@@ -135,104 +132,3 @@ def check_and_extract_service_configuration(service_config) -> dict:
"check_and_extract_service_configuration(%s) gives '%s'", service_config, ret
)
return ret
class VersatileThermostatBaseEntity(Entity):
"""A base class for all entities"""
_my_climate: BaseThermostat
hass: HomeAssistant
_config_id: str
_device_name: str
def __init__(self, hass: HomeAssistant, config_id, device_name) -> None:
"""The CTOR"""
self.hass = hass
self._config_id = config_id
self._device_name = device_name
self._my_climate = None
self._cancel_call = None
self._attr_has_entity_name = True
@property
def should_poll(self) -> bool:
"""Do not poll for those entities"""
return False
@property
def my_climate(self) -> BaseThermostat | None:
"""Returns my climate if found"""
if not self._my_climate:
self._my_climate = self.find_my_versatile_thermostat()
if self._my_climate:
# Only the first time
self.my_climate_is_initialized()
return self._my_climate
@property
def device_info(self) -> DeviceInfo:
"""Return the device info."""
return DeviceInfo(
entry_type=DeviceEntryType.SERVICE,
identifiers={(DOMAIN, self._config_id)},
name=self._device_name,
manufacturer=DEVICE_MANUFACTURER,
model=DOMAIN,
)
def find_my_versatile_thermostat(self) -> BaseThermostat:
"""Find the underlying climate entity"""
try:
component: EntityComponent[ClimateEntity] = self.hass.data[CLIMATE_DOMAIN]
for entity in component.entities:
# _LOGGER.debug("Device_info is %s", entity.device_info)
if entity.device_info == self.device_info:
_LOGGER.debug("Found %s!", entity)
return entity
except KeyError:
pass
return None
@callback
async def async_added_to_hass(self):
"""Listen to my climate state change"""
# Check delay condition
async def try_find_climate(_):
_LOGGER.debug(
"%s - Calling VersatileThermostatBaseEntity.async_added_to_hass", self
)
mcl = self.my_climate
if mcl:
if self._cancel_call:
self._cancel_call()
self._cancel_call = None
self.async_on_remove(
async_track_state_change_event(
self.hass,
[mcl.entity_id],
self.async_my_climate_changed,
)
)
else:
_LOGGER.debug("%s - no entity to listen. Try later", self)
self._cancel_call = async_call_later(
self.hass, timedelta(seconds=1), try_find_climate
)
await try_find_climate(None)
@callback
def my_climate_is_initialized(self):
"""Called when the associated climate is initialized"""
return
@callback
async def async_my_climate_changed(
self, event: Event
): # pylint: disable=unused-argument
"""Called when my climate have change
This method aims to be overriden to take the status change
"""
return

View File

@@ -6,7 +6,7 @@ from __future__ import annotations
from typing import Any
import logging
import copy
from collections.abc import Mapping
from collections.abc import Mapping # pylint: disable=import-error
import voluptuous as vol
from homeassistant.exceptions import HomeAssistantError
@@ -259,6 +259,21 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
if not self.check_valve_regulation_nb_entities(data, step_id):
raise ValveRegulationNbEntitiesIncorrect()
# Check that the min_opening_degrees is correctly set
raw_list = data.get(CONF_MIN_OPENING_DEGREES, None)
if raw_list:
try:
# Validation : Convertir la liste saisie
int_list = [int(x.strip()) for x in raw_list.split(",")]
# Optionnel : Vérifiez des conditions supplémentaires sur la liste
if any(x < 0 for x in int_list):
raise ValueError
except ValueError as exc:
raise ValveRegulationMinOpeningDegreesIncorrect(
CONF_MIN_OPENING_DEGREES
) from exc
def check_config_complete(self, infos) -> bool:
"""True if the config is now complete (ie all mandatory attributes are set)"""
is_central_config = (
@@ -399,6 +414,8 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
errors["base"] = "configuration_not_complete"
except ValveRegulationNbEntitiesIncorrect as err:
errors["base"] = "valve_regulation_nb_entities_incorrect"
except ValveRegulationMinOpeningDegreesIncorrect as err:
errors[str(err)] = "min_opening_degrees_format"
except Exception: # pylint: disable=broad-except
_LOGGER.exception("Unexpected exception")
errors["base"] = "unknown"
@@ -898,7 +915,7 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
)
class VersatileThermostatConfigFlow(
class VersatileThermostatConfigFlow( # pylint: disable=abstract-method
VersatileThermostatBaseConfigFlow, HAConfigFlow, domain=DOMAIN
):
"""Handle a config flow for Versatile Thermostat."""
@@ -912,6 +929,8 @@ class VersatileThermostatConfigFlow(
@callback
def async_get_options_flow(config_entry: ConfigEntry):
"""Get options flow for this handler"""
# #713 doesn't work as explained here:https://developers.home-assistant.io/blog/2024/11/12/options-flow
# should be - return VersatileThermostatOptionsFlowHandler() but hass is not initialized
return VersatileThermostatOptionsFlowHandler(config_entry)
async def async_step_finalize(self, _):
@@ -930,8 +949,12 @@ class VersatileThermostatOptionsFlowHandler(
def __init__(self, config_entry: ConfigEntry) -> None:
"""Initialize options flow."""
self._conf_app_id: str | None = None
super().__init__(config_entry.data.copy())
self.config_entry = config_entry
# #713
# self.config_entry = config_entry
_LOGGER.debug(
"CTOR VersatileThermostatOptionsFlowHandler info: %s, entry_id: %s",
self._infos,

View File

@@ -219,6 +219,7 @@ STEP_VALVE_REGULATION = vol.Schema( # pylint: disable=invalid-name
PROPORTIONAL_FUNCTION_TPI,
]
),
vol.Optional(CONF_MIN_OPENING_DEGREES, default=""): str,
}
)
@@ -367,14 +368,14 @@ STEP_PRESENCE_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
STEP_CENTRAL_ADVANCED_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
{
vol.Required(CONF_MINIMAL_ACTIVATION_DELAY, default=10): cv.positive_int,
vol.Required(CONF_SECURITY_DELAY_MIN, default=60): cv.positive_int,
vol.Required(CONF_SAFETY_DELAY_MIN, default=60): cv.positive_int,
vol.Required(
CONF_SECURITY_MIN_ON_PERCENT,
default=DEFAULT_SECURITY_MIN_ON_PERCENT,
CONF_SAFETY_MIN_ON_PERCENT,
default=DEFAULT_SAFETY_MIN_ON_PERCENT,
): vol.Coerce(float),
vol.Required(
CONF_SECURITY_DEFAULT_ON_PERCENT,
default=DEFAULT_SECURITY_DEFAULT_ON_PERCENT,
CONF_SAFETY_DEFAULT_ON_PERCENT,
default=DEFAULT_SAFETY_DEFAULT_ON_PERCENT,
): vol.Coerce(float),
}
)

View File

@@ -4,6 +4,7 @@
import logging
import math
from typing import Literal
from datetime import datetime
from enum import Enum
@@ -28,7 +29,7 @@ from .prop_algorithm import (
_LOGGER = logging.getLogger(__name__)
CONFIG_VERSION = 2
CONFIG_MINOR_VERSION = 0
CONFIG_MINOR_VERSION = 1
PRESET_TEMP_SUFFIX = "_temp"
PRESET_AC_SUFFIX = "_ac"
@@ -41,10 +42,10 @@ DEVICE_MANUFACTURER = "JMCOLLIN"
DEVICE_MODEL = "Versatile Thermostat"
PRESET_POWER = "power"
PRESET_SECURITY = "security"
PRESET_SAFETY = "security"
PRESET_FROST_PROTECTION = "frost"
HIDDEN_PRESETS = [PRESET_POWER, PRESET_SECURITY]
HIDDEN_PRESETS = [PRESET_POWER, PRESET_SAFETY]
DOMAIN = "versatile_thermostat"
@@ -83,9 +84,9 @@ CONF_PRESET_POWER = "power_temp"
CONF_MINIMAL_ACTIVATION_DELAY = "minimal_activation_delay"
CONF_TEMP_MIN = "temp_min"
CONF_TEMP_MAX = "temp_max"
CONF_SECURITY_DELAY_MIN = "security_delay_min"
CONF_SECURITY_MIN_ON_PERCENT = "security_min_on_percent"
CONF_SECURITY_DEFAULT_ON_PERCENT = "security_default_on_percent"
CONF_SAFETY_DELAY_MIN = "safety_delay_min"
CONF_SAFETY_MIN_ON_PERCENT = "safety_min_on_percent"
CONF_SAFETY_DEFAULT_ON_PERCENT = "safety_default_on_percent"
CONF_THERMOSTAT_TYPE = "thermostat_type"
CONF_THERMOSTAT_CENTRAL_CONFIG = "thermostat_central_config"
CONF_THERMOSTAT_SWITCH = "thermostat_over_switch"
@@ -123,6 +124,7 @@ CONF_STEP_TEMPERATURE = "step_temperature"
CONF_OFFSET_CALIBRATION_LIST = "offset_calibration_entity_ids"
CONF_OPENING_DEGREE_LIST = "opening_degree_entity_ids"
CONF_CLOSING_DEGREE_LIST = "closing_degree_entity_ids"
CONF_MIN_OPENING_DEGREES = "min_opening_degrees"
# Deprecated
CONF_HEATER = "heater_entity_id"
@@ -284,9 +286,9 @@ ALL_CONF = (
CONF_MINIMAL_ACTIVATION_DELAY,
CONF_TEMP_MIN,
CONF_TEMP_MAX,
CONF_SECURITY_DELAY_MIN,
CONF_SECURITY_MIN_ON_PERCENT,
CONF_SECURITY_DEFAULT_ON_PERCENT,
CONF_SAFETY_DELAY_MIN,
CONF_SAFETY_MIN_ON_PERCENT,
CONF_SAFETY_DEFAULT_ON_PERCENT,
CONF_THERMOSTAT_TYPE,
CONF_THERMOSTAT_SWITCH,
CONF_THERMOSTAT_CLIMATE,
@@ -372,13 +374,13 @@ SUPPORT_FLAGS = (
SERVICE_SET_PRESENCE = "set_presence"
SERVICE_SET_PRESET_TEMPERATURE = "set_preset_temperature"
SERVICE_SET_SECURITY = "set_security"
SERVICE_SET_SAFETY = "set_safety"
SERVICE_SET_WINDOW_BYPASS = "set_window_bypass"
SERVICE_SET_AUTO_REGULATION_MODE = "set_auto_regulation_mode"
SERVICE_SET_AUTO_FAN_MODE = "set_auto_fan_mode"
DEFAULT_SECURITY_MIN_ON_PERCENT = 0.5
DEFAULT_SECURITY_DEFAULT_ON_PERCENT = 0.1
DEFAULT_SAFETY_MIN_ON_PERCENT = 0.5
DEFAULT_SAFETY_DEFAULT_ON_PERCENT = 0.1
ATTR_TOTAL_ENERGY = "total_energy"
ATTR_MEAN_POWER_CYCLE = "mean_cycle_power"
@@ -552,6 +554,10 @@ class ValveRegulationNbEntitiesIncorrect(HomeAssistantError):
The number of specific entities is incorrect."""
class ValveRegulationMinOpeningDegreesIncorrect(HomeAssistantError):
"""Error to indicate that the minimal opening degrees is not a list of int separated by coma"""
class overrides: # pylint: disable=invalid-name
"""An annotation to inform overrides"""

View File

@@ -0,0 +1,236 @@
""" Implements the Auto-start/stop Feature Manager """
# pylint: disable=line-too-long
import logging
from typing import Any
from homeassistant.core import (
HomeAssistant,
)
from homeassistant.components.climate import HVACMode
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
from .commons import ConfigData
from .base_manager import BaseFeatureManager
from .auto_start_stop_algorithm import (
AutoStartStopDetectionAlgorithm,
AUTO_START_STOP_ACTION_OFF,
AUTO_START_STOP_ACTION_ON,
)
_LOGGER = logging.getLogger(__name__)
class FeatureAutoStartStopManager(BaseFeatureManager):
"""The implementation of the AutoStartStop feature"""
unrecorded_attributes = frozenset(
{
"auto_start_stop_level",
"auto_start_stop_dtmin",
"auto_start_stop_enable",
"auto_start_stop_accumulated_error",
"auto_start_stop_accumulated_error_threshold",
"auto_start_stop_last_switch_date",
}
)
def __init__(self, vtherm: Any, hass: HomeAssistant):
"""Init of a featureManager"""
super().__init__(vtherm, hass)
self._auto_start_stop_level: TYPE_AUTO_START_STOP_LEVELS = (
AUTO_START_STOP_LEVEL_NONE
)
self._auto_start_stop_algo: AutoStartStopDetectionAlgorithm | None = None
self._is_configured: bool = False
self._is_auto_start_stop_enabled: bool = False
@overrides
def post_init(self, entry_infos: ConfigData):
"""Reinit of the manager"""
use_auto_start_stop = entry_infos.get(CONF_USE_AUTO_START_STOP_FEATURE, False)
if use_auto_start_stop:
self._auto_start_stop_level = (
entry_infos.get(CONF_AUTO_START_STOP_LEVEL, None)
or AUTO_START_STOP_LEVEL_NONE
)
self._is_configured = True
else:
self._auto_start_stop_level = AUTO_START_STOP_LEVEL_NONE
self._is_configured = False
# Instanciate the auto start stop algo
self._auto_start_stop_algo = AutoStartStopDetectionAlgorithm(
self._auto_start_stop_level, self.name
)
@overrides
def start_listening(self):
"""Start listening the underlying entity"""
@overrides
def stop_listening(self):
"""Stop listening and remove the eventual timer still running"""
@overrides
async def refresh_state(self) -> bool:
"""Check the auto-start-stop and an eventual action
Return False if we should stop the control_heating method"""
if not self._is_configured or not self._is_auto_start_stop_enabled:
_LOGGER.debug("%s - auto start/stop is disabled (or not configured)", self)
return True
slope = (
self._vtherm.last_temperature_slope or 0
) / 60 # to have the slope in °/min
action = self._auto_start_stop_algo.calculate_action(
self._vtherm.hvac_mode,
self._vtherm.saved_hvac_mode,
self._vtherm.target_temperature,
self._vtherm.current_temperature,
slope,
self._vtherm.now,
)
_LOGGER.debug("%s - auto_start_stop action is %s", self, action)
if action == AUTO_START_STOP_ACTION_OFF and self._vtherm.is_on:
_LOGGER.info(
"%s - Turning OFF the Vtherm due to auto-start-stop conditions",
self,
)
self._vtherm.set_hvac_off_reason(HVAC_OFF_REASON_AUTO_START_STOP)
await self._vtherm.async_turn_off()
# Send an event
self._vtherm.send_event(
event_type=EventType.AUTO_START_STOP_EVENT,
data={
"type": "stop",
"name": self.name,
"cause": "Auto stop conditions reached",
"hvac_mode": self._vtherm.hvac_mode,
"saved_hvac_mode": self._vtherm.saved_hvac_mode,
"target_temperature": self._vtherm.target_temperature,
"current_temperature": self._vtherm.current_temperature,
"temperature_slope": round(slope, 3),
"accumulated_error": self._auto_start_stop_algo.accumulated_error,
"accumulated_error_threshold": self._auto_start_stop_algo.accumulated_error_threshold,
},
)
# Stop here
return False
elif (
action == AUTO_START_STOP_ACTION_ON
and self._vtherm.hvac_off_reason == HVAC_OFF_REASON_AUTO_START_STOP
):
_LOGGER.info(
"%s - Turning ON the Vtherm due to auto-start-stop conditions", self
)
await self._vtherm.async_turn_on()
# Send an event
self._vtherm.send_event(
event_type=EventType.AUTO_START_STOP_EVENT,
data={
"type": "start",
"name": self.name,
"cause": "Auto start conditions reached",
"hvac_mode": self._vtherm.hvac_mode,
"saved_hvac_mode": self._vtherm.saved_hvac_mode,
"target_temperature": self._vtherm.target_temperature,
"current_temperature": self._vtherm.current_temperature,
"temperature_slope": round(slope, 3),
"accumulated_error": self._auto_start_stop_algo.accumulated_error,
"accumulated_error_threshold": self._auto_start_stop_algo.accumulated_error_threshold,
},
)
self._vtherm.update_custom_attributes()
return True
def set_auto_start_stop_enable(self, is_enabled: bool):
"""Enable/Disable the auto-start/stop feature"""
self._is_auto_start_stop_enabled = is_enabled
if (
self._vtherm.hvac_mode == HVACMode.OFF
and self._vtherm.hvac_off_reason == HVAC_OFF_REASON_AUTO_START_STOP
):
_LOGGER.debug(
"%s - the vtherm is off cause auto-start/stop and enable have been set to false -> starts the VTherm"
)
self.hass.create_task(self._vtherm.async_turn_on())
# Send an event
self._vtherm.send_event(
event_type=EventType.AUTO_START_STOP_EVENT,
data={
"type": "start",
"name": self.name,
"cause": "Auto start stop disabled",
"hvac_mode": self._vtherm.hvac_mode,
"saved_hvac_mode": self._vtherm.saved_hvac_mode,
"target_temperature": self._vtherm.target_temperature,
"current_temperature": self._vtherm.current_temperature,
"temperature_slope": round(
self._vtherm.last_temperature_slope or 0, 3
),
"accumulated_error": self._auto_start_stop_algo.accumulated_error,
"accumulated_error_threshold": self._auto_start_stop_algo.accumulated_error_threshold,
},
)
self._vtherm.update_custom_attributes()
def add_custom_attributes(self, extra_state_attributes: dict[str, Any]):
"""Add some custom attributes"""
extra_state_attributes.update(
{
"is_auto_start_stop_configured": self.is_configured,
}
)
if self.is_configured:
extra_state_attributes.update(
{
"auto_start_stop_enable": self.auto_start_stop_enable,
"auto_start_stop_level": self._auto_start_stop_algo.level,
"auto_start_stop_dtmin": self._auto_start_stop_algo.dt_min,
"auto_start_stop_accumulated_error": self._auto_start_stop_algo.accumulated_error,
"auto_start_stop_accumulated_error_threshold": self._auto_start_stop_algo.accumulated_error_threshold,
"auto_start_stop_last_switch_date": self._auto_start_stop_algo.last_switch_date,
}
)
@overrides
@property
def is_configured(self) -> bool:
"""Return True of the aiuto-start/stop feature is configured"""
return self._is_configured
@property
def auto_start_stop_level(self) -> TYPE_AUTO_START_STOP_LEVELS:
"""Return the auto start/stop level."""
return self._auto_start_stop_level
@property
def auto_start_stop_enable(self) -> bool:
"""Returns the auto_start_stop_enable"""
return self._is_auto_start_stop_enabled
@property
def is_auto_stopped(self) -> bool:
"""Returns the is vtherm is stopped and reason is AUTO_START_STOP"""
return (
self._vtherm.hvac_mode == HVACMode.OFF
and self._vtherm.hvac_off_reason == HVAC_OFF_REASON_AUTO_START_STOP
)
def __str__(self):
return f"AutoStartStopManager-{self.name}"

View File

@@ -0,0 +1,343 @@
""" Implements the Motion Feature Manager """
# pylint: disable=line-too-long
import logging
from typing import Any
from datetime import timedelta
from homeassistant.const import (
STATE_ON,
STATE_OFF,
STATE_UNAVAILABLE,
STATE_UNKNOWN,
)
from homeassistant.core import (
HomeAssistant,
callback,
Event,
)
from homeassistant.helpers.event import (
async_track_state_change_event,
EventStateChangedData,
async_call_later,
)
from homeassistant.components.climate import (
PRESET_ACTIVITY,
)
from homeassistant.exceptions import ConditionError
from homeassistant.helpers import condition
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
from .commons import ConfigData
from .base_manager import BaseFeatureManager
_LOGGER = logging.getLogger(__name__)
class FeatureMotionManager(BaseFeatureManager):
"""The implementation of the Motion feature"""
unrecorded_attributes = frozenset(
{
"motion_sensor_entity_id",
"is_motion_configured",
"motion_delay_sec",
"motion_off_delay_sec",
"motion_preset",
"no_motion_preset",
}
)
def __init__(self, vtherm: Any, hass: HomeAssistant):
"""Init of a featureManager"""
super().__init__(vtherm, hass)
self._motion_state: str = STATE_UNAVAILABLE
self._motion_sensor_entity_id: str = None
self._motion_delay_sec: int | None = 0
self._motion_off_delay_sec: int | None = 0
self._motion_preset: str | None = None
self._no_motion_preset: str | None = None
self._is_configured: bool = False
self._motion_call_cancel: callable = None
@overrides
def post_init(self, entry_infos: ConfigData):
"""Reinit of the manager"""
self.dearm_motion_timer()
self._motion_sensor_entity_id = entry_infos.get(CONF_MOTION_SENSOR, None)
self._motion_delay_sec = entry_infos.get(CONF_MOTION_DELAY, 0)
self._motion_off_delay_sec = entry_infos.get(CONF_MOTION_OFF_DELAY, None)
if not self._motion_off_delay_sec:
self._motion_off_delay_sec = self._motion_delay_sec
self._motion_preset = entry_infos.get(CONF_MOTION_PRESET)
self._no_motion_preset = entry_infos.get(CONF_NO_MOTION_PRESET)
if (
self._motion_sensor_entity_id is not None
and self._motion_preset is not None
and self._no_motion_preset is not None
):
self._is_configured = True
self._motion_state = STATE_UNKNOWN
@overrides
def start_listening(self):
"""Start listening the underlying entity"""
if self._is_configured:
self.stop_listening()
self.add_listener(
async_track_state_change_event(
self.hass,
[self._motion_sensor_entity_id],
self._motion_sensor_changed,
)
)
@overrides
def stop_listening(self):
"""Stop listening and remove the eventual timer still running"""
self.dearm_motion_timer()
super().stop_listening()
def dearm_motion_timer(self):
"""Dearm the eventual motion time running"""
if self._motion_call_cancel:
self._motion_call_cancel()
self._motion_call_cancel = None
@overrides
async def refresh_state(self) -> bool:
"""Tries to get the last state from sensor
Returns True if a change has been made"""
ret = False
if self._is_configured:
motion_state = self.hass.states.get(self._motion_sensor_entity_id)
if motion_state and motion_state.state not in (
STATE_UNAVAILABLE,
STATE_UNKNOWN,
):
_LOGGER.debug(
"%s - Motion state have been retrieved: %s",
self,
self._motion_state,
)
# recalculate the right target_temp in activity mode
ret = await self.update_motion_state(motion_state.state, False)
return ret
@callback
async def _motion_sensor_changed(self, event: Event[EventStateChangedData]):
"""Handle motion sensor changes."""
new_state = event.data.get("new_state")
_LOGGER.info(
"%s - Motion changed. Event.new_state is %s, _attr_preset_mode=%s, activity=%s",
self,
new_state,
self._vtherm.preset_mode,
PRESET_ACTIVITY,
)
if new_state is None or new_state.state not in (STATE_OFF, STATE_ON):
return
# Check delay condition
async def try_motion_condition(_):
self.dearm_motion_timer()
try:
delay = (
self._motion_delay_sec
if new_state.state == STATE_ON
else self._motion_off_delay_sec
)
long_enough = condition.state(
self.hass,
self._motion_sensor_entity_id,
new_state.state,
timedelta(seconds=delay),
)
except ConditionError:
long_enough = False
if not long_enough:
_LOGGER.debug(
"Motion delay condition is not satisfied (the sensor have change its state during the delay). Check motion sensor state"
)
# Get sensor current state
motion_state = self.hass.states.get(self._motion_sensor_entity_id)
_LOGGER.debug(
"%s - motion_state=%s, new_state.state=%s",
self,
motion_state.state,
new_state.state,
)
if (
motion_state.state == new_state.state
and new_state.state == STATE_ON
):
_LOGGER.debug(
"%s - the motion sensor is finally 'on' after the delay", self
)
long_enough = True
else:
long_enough = False
if long_enough:
_LOGGER.debug("%s - Motion delay condition is satisfied", self)
await self.update_motion_state(new_state.state)
else:
await self.update_motion_state(
STATE_ON if new_state.state == STATE_OFF else STATE_OFF
)
im_on = self._motion_state == STATE_ON
delay_running = self._motion_call_cancel is not None
event_on = new_state.state == STATE_ON
def arm():
"""Arm the timer"""
delay = (
self._motion_delay_sec
if new_state.state == STATE_ON
else self._motion_off_delay_sec
)
self._motion_call_cancel = async_call_later(
self.hass, timedelta(seconds=delay), try_motion_condition
)
# if I'm off
if not im_on:
if event_on and not delay_running:
_LOGGER.debug(
"%s - Arm delay cause i'm off and event is on and no delay is running",
self,
)
arm()
return try_motion_condition
# Ignore the event
_LOGGER.debug("%s - Event ignored cause i'm already off", self)
return None
else: # I'm On
if not event_on and not delay_running:
_LOGGER.info("%s - Arm delay cause i'm on and event is off", self)
arm()
return try_motion_condition
if event_on and delay_running:
_LOGGER.debug(
"%s - Desarm off delay cause i'm on and event is on and a delay is running",
self,
)
self.dearm_motion_timer()
return None
# Ignore the event
_LOGGER.debug("%s - Event ignored cause i'm already on", self)
return None
async def update_motion_state(
self, new_state: str = None, recalculate: bool = True
) -> bool:
"""Update the value of the motion sensor and update the VTherm state accordingly
Return true if a change has been made"""
_LOGGER.info("%s - Updating motion state. New state is %s", self, new_state)
old_motion_state = self._motion_state
if new_state is not None:
self._motion_state = STATE_ON if new_state == STATE_ON else STATE_OFF
if self._vtherm.preset_mode == PRESET_ACTIVITY:
new_preset = self.get_current_motion_preset()
_LOGGER.info(
"%s - Motion condition have changes. New preset temp will be %s",
self,
new_preset,
)
# We do not change the preset which is kept to ACTIVITY but only the target_temperature
# We take the motion into account
new_temp = self._vtherm.find_preset_temp(new_preset)
old_temp = self._vtherm.target_temperature
if new_temp != old_temp:
await self._vtherm.change_target_temperature(new_temp)
if new_temp != old_temp and recalculate:
self._vtherm.recalculate()
await self._vtherm.async_control_heating(force=True)
return old_motion_state != self._motion_state
def get_current_motion_preset(self) -> str:
"""Calculate and return the current motion preset"""
return (
self._motion_preset
if self._motion_state == STATE_ON
else self._no_motion_preset
)
def add_custom_attributes(self, extra_state_attributes: dict[str, Any]):
"""Add some custom attributes"""
extra_state_attributes.update(
{
"motion_sensor_entity_id": self._motion_sensor_entity_id,
"motion_state": self._motion_state,
"is_motion_configured": self._is_configured,
"motion_delay_sec": self._motion_delay_sec,
"motion_off_delay_sec": self._motion_off_delay_sec,
"motion_preset": self._motion_preset,
"no_motion_preset": self._no_motion_preset,
}
)
@overrides
@property
def is_configured(self) -> bool:
"""Return True of the motion is configured"""
return self._is_configured
@property
def motion_state(self) -> str | None:
"""Return the current motion state STATE_ON or STATE_OFF
or STATE_UNAVAILABLE if not configured"""
if not self._is_configured:
return STATE_UNAVAILABLE
return self._motion_state
@property
def is_motion_detected(self) -> bool:
"""Return true if the motion is configured and motion sensor is OFF"""
return self._is_configured and self._motion_state in [
STATE_ON,
]
@property
def motion_sensor_entity_id(self) -> bool:
"""Return true if the motion is configured and motion sensor is OFF"""
return self._motion_sensor_entity_id
@property
def motion_delay_sec(self) -> bool:
"""Return the motion delay"""
return self._motion_delay_sec
@property
def motion_off_delay_sec(self) -> bool:
"""Return motion delay off"""
return self._motion_off_delay_sec
@property
def motion_preset(self) -> bool:
"""Return motion preset"""
return self._motion_preset
@property
def no_motion_preset(self) -> bool:
"""Return no motion preset"""
return self._no_motion_preset
def __str__(self):
return f"MotionManager-{self.name}"

View File

@@ -0,0 +1,368 @@
""" Implements the Power Feature Manager """
# pylint: disable=line-too-long
import logging
from typing import Any
from homeassistant.const import (
STATE_ON,
STATE_OFF,
STATE_UNAVAILABLE,
STATE_UNKNOWN,
)
from homeassistant.core import (
HomeAssistant,
callback,
Event,
)
from homeassistant.helpers.event import (
async_track_state_change_event,
EventStateChangedData,
)
from homeassistant.components.climate import HVACMode
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
from .commons import ConfigData
from .base_manager import BaseFeatureManager
_LOGGER = logging.getLogger(__name__)
class FeaturePowerManager(BaseFeatureManager):
"""The implementation of the Power feature"""
unrecorded_attributes = frozenset(
{
"power_sensor_entity_id",
"max_power_sensor_entity_id",
"is_power_configured",
"device_power",
"power_temp",
"current_power",
"current_max_power",
}
)
def __init__(self, vtherm: Any, hass: HomeAssistant):
"""Init of a featureManager"""
super().__init__(vtherm, hass)
self._power_sensor_entity_id = None
self._max_power_sensor_entity_id = None
self._current_power = None
self._current_max_power = None
self._power_temp = None
self._overpowering_state = STATE_UNAVAILABLE
self._is_configured: bool = False
self._device_power: float = 0
@overrides
def post_init(self, entry_infos: ConfigData):
"""Reinit of the manager"""
# Power management
self._power_sensor_entity_id = entry_infos.get(CONF_POWER_SENSOR)
self._max_power_sensor_entity_id = entry_infos.get(CONF_MAX_POWER_SENSOR)
self._power_temp = entry_infos.get(CONF_PRESET_POWER)
self._device_power = entry_infos.get(CONF_DEVICE_POWER) or 0
self._is_configured = False
self._current_power = None
self._current_max_power = None
if (
entry_infos.get(CONF_USE_POWER_FEATURE, False)
and self._max_power_sensor_entity_id
and self._power_sensor_entity_id
and self._device_power
):
self._is_configured = True
self._overpowering_state = STATE_UNKNOWN
else:
_LOGGER.info("%s - Power management is not fully configured", self)
@overrides
def start_listening(self):
"""Start listening the underlying entity"""
if self._is_configured:
self.stop_listening()
else:
return
self.add_listener(
async_track_state_change_event(
self.hass,
[self._power_sensor_entity_id],
self._async_power_sensor_changed,
)
)
self.add_listener(
async_track_state_change_event(
self.hass,
[self._max_power_sensor_entity_id],
self._async_max_power_sensor_changed,
)
)
@overrides
async def refresh_state(self) -> bool:
"""Tries to get the last state from sensor
Returns True if a change has been made"""
ret = False
if self._is_configured:
# try to acquire current power and power max
current_power_state = self.hass.states.get(self._power_sensor_entity_id)
if current_power_state and current_power_state.state not in (
STATE_UNAVAILABLE,
STATE_UNKNOWN,
):
self._current_power = float(current_power_state.state)
_LOGGER.debug(
"%s - Current power have been retrieved: %.3f",
self,
self._current_power,
)
ret = True
# Try to acquire power max
current_power_max_state = self.hass.states.get(
self._max_power_sensor_entity_id
)
if current_power_max_state and current_power_max_state.state not in (
STATE_UNAVAILABLE,
STATE_UNKNOWN,
):
self._current_max_power = float(current_power_max_state.state)
_LOGGER.debug(
"%s - Current power max have been retrieved: %.3f",
self,
self._current_max_power,
)
ret = True
return ret
@callback
async def _async_power_sensor_changed(self, event: Event[EventStateChangedData]):
"""Handle power changes."""
_LOGGER.debug("Thermostat %s - Receive new Power event", self)
_LOGGER.debug(event)
new_state = event.data.get("new_state")
old_state = event.data.get("old_state")
if (
new_state is None
or new_state.state in (STATE_UNAVAILABLE, STATE_UNKNOWN)
or (old_state is not None and new_state.state == old_state.state)
):
return
try:
current_power = float(new_state.state)
if math.isnan(current_power) or math.isinf(current_power):
raise ValueError(f"Sensor has illegal state {new_state.state}")
self._current_power = current_power
if self._vtherm.preset_mode == PRESET_POWER:
await self._vtherm.async_control_heating()
except ValueError as ex:
_LOGGER.error("Unable to update current_power from sensor: %s", ex)
@callback
async def _async_max_power_sensor_changed(
self, event: Event[EventStateChangedData]
):
"""Handle power max changes."""
_LOGGER.debug("Thermostat %s - Receive new Power Max event", self.name)
_LOGGER.debug(event)
new_state = event.data.get("new_state")
old_state = event.data.get("old_state")
if (
new_state is None
or new_state.state in (STATE_UNAVAILABLE, STATE_UNKNOWN)
or (old_state is not None and new_state.state == old_state.state)
):
return
try:
current_power_max = float(new_state.state)
if math.isnan(current_power_max) or math.isinf(current_power_max):
raise ValueError(f"Sensor has illegal state {new_state.state}")
self._current_max_power = current_power_max
if self._vtherm.preset_mode == PRESET_POWER:
await self._vtherm.async_control_heating()
except ValueError as ex:
_LOGGER.error("Unable to update current_power from sensor: %s", ex)
def add_custom_attributes(self, extra_state_attributes: dict[str, Any]):
"""Add some custom attributes"""
extra_state_attributes.update(
{
"power_sensor_entity_id": self._power_sensor_entity_id,
"max_power_sensor_entity_id": self._max_power_sensor_entity_id,
"overpowering_state": self._overpowering_state,
"is_power_configured": self._is_configured,
"device_power": self._device_power,
"power_temp": self._power_temp,
"current_power": self._current_power,
"current_max_power": self._current_max_power,
"mean_cycle_power": self.mean_cycle_power,
}
)
async def check_overpowering(self) -> bool:
"""Check the overpowering condition
Turn the preset_mode of the heater to 'power' if power conditions are exceeded
Returns True if overpowering is 'on'
"""
if not self._is_configured:
return False
if (
self._current_power is None
or self._device_power is None
or self._current_max_power is None
):
_LOGGER.warning(
"%s - power not valued. check_overpowering not available", self
)
return False
_LOGGER.debug(
"%s - overpowering check: power=%.3f, max_power=%.3f heater power=%.3f",
self,
self._current_power,
self._current_max_power,
self._device_power,
)
# issue 407 - power_consumption_max is power we need to add. If already active we don't need to add more power
if self._vtherm.is_device_active:
power_consumption_max = 0
else:
if self._vtherm.is_over_climate:
power_consumption_max = self._device_power
else:
power_consumption_max = max(
self._device_power / self._vtherm.nb_underlying_entities,
self._device_power * self._vtherm.proportional_algorithm.on_percent,
)
ret = (self._current_power + power_consumption_max) >= self._current_max_power
if (
self._overpowering_state == STATE_OFF
and ret
and self._vtherm.hvac_mode != HVACMode.OFF
):
_LOGGER.warning(
"%s - overpowering is detected. Heater preset will be set to 'power'",
self,
)
if self._vtherm.is_over_climate:
self._vtherm.save_hvac_mode()
self._vtherm.save_preset_mode()
await self._vtherm.async_underlying_entity_turn_off()
await self._vtherm.async_set_preset_mode_internal(PRESET_POWER)
self._vtherm.send_event(
EventType.POWER_EVENT,
{
"type": "start",
"current_power": self._current_power,
"device_power": self._device_power,
"current_max_power": self._current_max_power,
"current_power_consumption": power_consumption_max,
},
)
# Check if we need to remove the POWER preset
if (
self._overpowering_state == STATE_ON
and not ret
and self._vtherm.preset_mode == PRESET_POWER
):
_LOGGER.warning(
"%s - end of overpowering is detected. Heater preset will be restored to '%s'",
self,
self._vtherm._saved_preset_mode, # pylint: disable=protected-access
)
if self._vtherm.is_over_climate:
await self._vtherm.restore_hvac_mode(False)
await self._vtherm.restore_preset_mode()
self._vtherm.send_event(
EventType.POWER_EVENT,
{
"type": "end",
"current_power": self._current_power,
"device_power": self._device_power,
"current_max_power": self._current_max_power,
},
)
new_overpowering_state = STATE_ON if ret else STATE_OFF
if self._overpowering_state != new_overpowering_state:
self._overpowering_state = new_overpowering_state
self._vtherm.update_custom_attributes()
return self._overpowering_state == STATE_ON
@overrides
@property
def is_configured(self) -> bool:
"""Return True of the presence is configured"""
return self._is_configured
@property
def overpowering_state(self) -> str | None:
"""Return the current overpowering state STATE_ON or STATE_OFF
or STATE_UNAVAILABLE if not configured"""
if not self._is_configured:
return STATE_UNAVAILABLE
return self._overpowering_state
@property
def max_power_sensor_entity_id(self) -> bool:
"""Return the power max entity id"""
return self._max_power_sensor_entity_id
@property
def power_sensor_entity_id(self) -> bool:
"""Return the power entity id"""
return self._power_sensor_entity_id
@property
def power_temperature(self) -> bool:
"""Return the power temperature"""
return self._power_temp
@property
def device_power(self) -> bool:
"""Return the device power"""
return self._device_power
@property
def current_power(self) -> bool:
"""Return the current power from sensor"""
return self._current_power
@property
def current_max_power(self) -> bool:
"""Return the current power from sensor"""
return self._current_max_power
@property
def mean_cycle_power(self) -> float | None:
"""Returns the mean power consumption during the cycle"""
if not self._device_power or not self._vtherm.proportional_algorithm:
return None
return float(
self._device_power * self._vtherm.proportional_algorithm.on_percent
)
def __str__(self):
return f"PowerManager-{self.name}"

View File

@@ -0,0 +1,204 @@
""" Implements the Presence Feature Manager """
# pylint: disable=line-too-long
import logging
from typing import Any
from homeassistant.const import (
STATE_ON,
STATE_OFF,
STATE_HOME,
STATE_NOT_HOME,
STATE_UNAVAILABLE,
STATE_UNKNOWN,
)
from homeassistant.core import (
HomeAssistant,
callback,
Event,
)
from homeassistant.helpers.event import (
async_track_state_change_event,
EventStateChangedData,
)
from homeassistant.components.climate import (
PRESET_ACTIVITY,
PRESET_BOOST,
PRESET_COMFORT,
PRESET_ECO,
)
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
from .commons import ConfigData
from .base_manager import BaseFeatureManager
_LOGGER = logging.getLogger(__name__)
class FeaturePresenceManager(BaseFeatureManager):
"""The implementation of the Presence feature"""
unrecorded_attributes = frozenset(
{
"presence_sensor_entity_id",
"is_presence_configured",
}
)
def __init__(self, vtherm: Any, hass: HomeAssistant):
"""Init of a featureManager"""
super().__init__(vtherm, hass)
self._presence_state: str = STATE_UNAVAILABLE
self._presence_sensor_entity_id: str = None
self._is_configured: bool = False
@overrides
def post_init(self, entry_infos: ConfigData):
"""Reinit of the manager"""
self._presence_sensor_entity_id = entry_infos.get(CONF_PRESENCE_SENSOR)
if (
entry_infos.get(CONF_USE_PRESENCE_FEATURE, False)
and self._presence_sensor_entity_id is not None
):
self._is_configured = True
self._presence_state = STATE_UNKNOWN
@overrides
def start_listening(self):
"""Start listening the underlying entity"""
if self._is_configured:
self.stop_listening()
self.add_listener(
async_track_state_change_event(
self.hass,
[self._presence_sensor_entity_id],
self._presence_sensor_changed,
)
)
@overrides
async def refresh_state(self) -> bool:
"""Tries to get the last state from sensor
Returns True if a change has been made"""
ret = False
if self._is_configured:
# try to acquire presence entity state
presence_state = self.hass.states.get(self._presence_sensor_entity_id)
if presence_state and presence_state.state not in (
STATE_UNAVAILABLE,
STATE_UNKNOWN,
):
ret = await self.update_presence(presence_state.state)
_LOGGER.debug(
"%s - Presence have been retrieved: %s",
self,
presence_state.state,
)
return ret
@callback
async def _presence_sensor_changed(self, event: Event[EventStateChangedData]):
"""Handle presence changes."""
new_state = event.data.get("new_state")
_LOGGER.info(
"%s - Presence changed. Event.new_state is %s, _attr_preset_mode=%s, activity=%s",
self,
new_state,
self._vtherm.preset_mode,
PRESET_ACTIVITY,
)
if new_state is None:
return
if await self.update_presence(new_state.state):
await self._vtherm.async_control_heating(force=True)
async def update_presence(self, new_state: str) -> bool:
"""Update the value of the presence sensor and update the VTherm state accordingly
Return true if a change has been made"""
_LOGGER.info("%s - Updating presence. New state is %s", self, new_state)
old_presence_state = self._presence_state
self._presence_state = (
STATE_ON if new_state in (STATE_ON, STATE_HOME) else STATE_OFF
)
if self._vtherm.preset_mode in HIDDEN_PRESETS or self._is_configured is False:
_LOGGER.info(
"%s - Ignoring presence change cause in Power or Security preset or presence not configured",
self,
)
return old_presence_state != self._presence_state
if new_state is None or new_state not in (
STATE_OFF,
STATE_ON,
STATE_HOME,
STATE_NOT_HOME,
):
self._presence_state = STATE_UNKNOWN
return old_presence_state != self._presence_state
if self._vtherm.preset_mode not in [
PRESET_BOOST,
PRESET_COMFORT,
PRESET_ECO,
PRESET_ACTIVITY,
]:
return old_presence_state != self._presence_state
new_temp = self._vtherm.find_preset_temp(self._vtherm.preset_mode)
if new_temp is not None:
_LOGGER.debug(
"%s - presence change in temperature mode new_temp will be: %.2f",
self,
new_temp,
)
await self._vtherm.change_target_temperature(new_temp)
self._vtherm.recalculate()
return True
return old_presence_state != self._presence_state
def add_custom_attributes(self, extra_state_attributes: dict[str, Any]):
"""Add some custom attributes"""
extra_state_attributes.update(
{
"presence_sensor_entity_id": self._presence_sensor_entity_id,
"presence_state": self._presence_state,
"is_presence_configured": self._is_configured,
}
)
@overrides
@property
def is_configured(self) -> bool:
"""Return True of the presence is configured"""
return self._is_configured
@property
def presence_state(self) -> str | None:
"""Return the current presence state STATE_ON or STATE_OFF
or STATE_UNAVAILABLE if not configured"""
if not self._is_configured:
return STATE_UNAVAILABLE
return self._presence_state
@property
def is_absence_detected(self) -> bool:
"""Return true if the presence is configured and presence sensor is OFF"""
return self._is_configured and self._presence_state in [
STATE_NOT_HOME,
STATE_OFF,
]
@property
def presence_sensor_entity_id(self) -> bool:
"""Return true if the presence is configured and presence sensor is OFF"""
return self._presence_sensor_entity_id
def __str__(self):
return f"PresenceManager-{self.name}"

View File

@@ -0,0 +1,322 @@
# pylint: disable=line-too-long
""" Implements the Safety as a Feature Manager"""
import logging
from typing import Any
from homeassistant.const import (
STATE_ON,
STATE_OFF,
STATE_UNAVAILABLE,
STATE_UNKNOWN,
)
from homeassistant.core import HomeAssistant
from homeassistant.components.climate import HVACMode, HVACAction
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
from .commons import ConfigData
from .base_manager import BaseFeatureManager
from .vtherm_api import VersatileThermostatAPI
_LOGGER = logging.getLogger(__name__)
class FeatureSafetyManager(BaseFeatureManager):
"""The implementation of the Safety feature"""
unrecorded_attributes = frozenset(
{
"safety_delay_min",
"safety_min_on_percent",
"safety_default_on_percent",
"is_safety_configured",
}
)
def __init__(self, vtherm: Any, hass: HomeAssistant):
"""Init of a featureManager"""
super().__init__(vtherm, hass)
self._is_configured: bool = False
self._safety_delay_min = None
self._safety_min_on_percent = None
self._safety_default_on_percent = None
self._safety_state = STATE_UNAVAILABLE
@overrides
def post_init(self, entry_infos: ConfigData):
"""Reinit of the manager"""
self._safety_delay_min = entry_infos.get(CONF_SAFETY_DELAY_MIN)
self._safety_min_on_percent = (
entry_infos.get(CONF_SAFETY_MIN_ON_PERCENT)
if entry_infos.get(CONF_SAFETY_MIN_ON_PERCENT) is not None
else DEFAULT_SAFETY_MIN_ON_PERCENT
)
self._safety_default_on_percent = (
entry_infos.get(CONF_SAFETY_DEFAULT_ON_PERCENT)
if entry_infos.get(CONF_SAFETY_DEFAULT_ON_PERCENT) is not None
else DEFAULT_SAFETY_DEFAULT_ON_PERCENT
)
if (
self._safety_delay_min is not None
and self._safety_default_on_percent is not None
and self._safety_default_on_percent is not None
):
self._safety_state = STATE_UNKNOWN
self._is_configured = True
@overrides
def start_listening(self):
"""Start listening the underlying entity"""
@overrides
def stop_listening(self):
"""Stop listening and remove the eventual timer still running"""
@overrides
async def refresh_state(self) -> bool:
"""Check the safety and an eventual action
Return True is safety should be active"""
if not self._is_configured:
_LOGGER.debug("%s - safety is disabled (or not configured)", self)
return False
now = self._vtherm.now
current_tz = dt_util.get_time_zone(self._hass.config.time_zone)
is_safety_detected = self.is_safety_detected
delta_temp = (
now - self._vtherm.last_temperature_measure.replace(tzinfo=current_tz)
).total_seconds() / 60.0
delta_ext_temp = (
now - self._vtherm.last_ext_temperature_measure.replace(tzinfo=current_tz)
).total_seconds() / 60.0
mode_cond = self._vtherm.hvac_mode != HVACMode.OFF
api: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api()
is_outdoor_checked = (
not api.safety_mode
or api.safety_mode.get("check_outdoor_sensor") is not False
)
temp_cond: bool = delta_temp > self._safety_delay_min or (
is_outdoor_checked and delta_ext_temp > self._safety_delay_min
)
climate_cond: bool = (
self._vtherm.is_over_climate
and self._vtherm.hvac_action
not in [
HVACAction.COOLING,
HVACAction.IDLE,
]
)
switch_cond: bool = (
not self._vtherm.is_over_climate
and self._vtherm.proportional_algorithm is not None
and self._vtherm.proportional_algorithm.calculated_on_percent
>= self._safety_min_on_percent
)
_LOGGER.debug(
"%s - checking safety delta_temp=%.1f delta_ext_temp=%.1f mod_cond=%s temp_cond=%s climate_cond=%s switch_cond=%s",
self,
delta_temp,
delta_ext_temp,
mode_cond,
temp_cond,
climate_cond,
switch_cond,
)
# Issue 99 - a climate is regulated by the device itself and not by VTherm. So a VTherm should never be in safety !
should_climate_be_in_security = False # temp_cond and climate_cond
should_switch_be_in_security = temp_cond and switch_cond
should_be_in_security = (
should_climate_be_in_security or should_switch_be_in_security
)
should_start_security = (
mode_cond and not is_safety_detected and should_be_in_security
)
# attr_preset_mode is not necessary normaly. It is just here to be sure
should_stop_security = (
is_safety_detected
and not should_be_in_security
and self._vtherm.preset_mode == PRESET_SAFETY
)
# Logging and event
if should_start_security:
if should_climate_be_in_security:
_LOGGER.warning(
"%s - No temperature received for more than %.1f minutes (dt=%.1f, dext=%.1f) and underlying climate is %s. Setting it into safety mode",
self,
self._safety_delay_min,
delta_temp,
delta_ext_temp,
self.hvac_action,
)
elif should_switch_be_in_security:
_LOGGER.warning(
"%s - No temperature received for more than %.1f minutes (dt=%.1f, dext=%.1f) and on_percent (%.2f %%) is over defined value (%.2f %%). Set it into safety mode",
self,
self._safety_delay_min,
delta_temp,
delta_ext_temp,
self._vtherm.proportional_algorithm.on_percent * 100,
self._safety_min_on_percent * 100,
)
self._vtherm.send_event(
EventType.TEMPERATURE_EVENT,
{
"last_temperature_measure": self._vtherm.last_temperature_measure.replace(
tzinfo=current_tz
).isoformat(),
"last_ext_temperature_measure": self._vtherm.last_ext_temperature_measure.replace(
tzinfo=current_tz
).isoformat(),
"current_temp": self._vtherm.current_temperature,
"current_ext_temp": self._vtherm.current_outdoor_temperature,
"target_temp": self._vtherm.target_temperature,
},
)
# Start safety mode
if should_start_security:
self._safety_state = STATE_ON
self._vtherm.save_hvac_mode()
self._vtherm.save_preset_mode()
if self._vtherm.proportional_algorithm:
self._vtherm.proportional_algorithm.set_safety(
self._safety_default_on_percent
)
await self._vtherm.async_set_preset_mode_internal(PRESET_SAFETY)
# Turn off the underlying climate or heater if safety default on_percent is 0
if self._vtherm.is_over_climate or self._safety_default_on_percent <= 0.0:
await self._vtherm.async_set_hvac_mode(HVACMode.OFF, False)
self._vtherm.send_event(
EventType.SECURITY_EVENT,
{
"type": "start",
"last_temperature_measure": self._vtherm.last_temperature_measure.replace(
tzinfo=current_tz
).isoformat(),
"last_ext_temperature_measure": self._vtherm.last_ext_temperature_measure.replace(
tzinfo=current_tz
).isoformat(),
"current_temp": self._vtherm.current_temperature,
"current_ext_temp": self._vtherm.current_outdoor_temperature,
"target_temp": self._vtherm.target_temperature,
},
)
# Stop safety mode
elif should_stop_security:
_LOGGER.warning(
"%s - End of safety mode. restoring hvac_mode to %s and preset_mode to %s",
self,
self._vtherm.saved_hvac_mode,
self._vtherm.saved_preset_mode,
)
self._safety_state = STATE_OFF
if self._vtherm.proportional_algorithm:
self._vtherm.proportional_algorithm.unset_safety()
# Restore hvac_mode if previously saved
if self._vtherm.is_over_climate or self._safety_default_on_percent <= 0.0:
await self._vtherm.restore_hvac_mode(False)
await self._vtherm.restore_preset_mode()
self._vtherm.send_event(
EventType.SECURITY_EVENT,
{
"type": "end",
"last_temperature_measure": self._vtherm.last_temperature_measure.replace(
tzinfo=current_tz
).isoformat(),
"last_ext_temperature_measure": self._vtherm.last_ext_temperature_measure.replace(
tzinfo=current_tz
).isoformat(),
"current_temp": self._vtherm.current_temperature,
"current_ext_temp": self._vtherm.current_outdoor_temperature,
"target_temp": self._vtherm.target_temperature,
},
)
# Initialize the safety_state if not already done
elif not should_be_in_security and self._safety_state in [STATE_UNKNOWN]:
self._safety_state = STATE_OFF
return should_be_in_security
def add_custom_attributes(self, extra_state_attributes: dict[str, Any]):
"""Add some custom attributes"""
extra_state_attributes.update(
{
"is_safety_configured": self._is_configured,
"safety_state": self._safety_state,
}
)
if self._is_configured:
extra_state_attributes.update(
{
"safety_delay_min": self._safety_delay_min,
"safety_min_on_percent": self._safety_min_on_percent,
"safety_default_on_percent": self._safety_default_on_percent,
}
)
@overrides
@property
def is_configured(self) -> bool:
"""Return True of the safety feature is configured"""
return self._is_configured
def set_safety_delay_min(self, safety_delay_min):
"""Set the delay min"""
self._safety_delay_min = safety_delay_min
def set_safety_min_on_percent(self, safety_min_on_percent):
"""Set the min on percent"""
self._safety_min_on_percent = safety_min_on_percent
def set_safety_default_on_percent(self, safety_default_on_percent):
"""Set the default on_percent"""
self._safety_default_on_percent = safety_default_on_percent
@property
def is_safety_detected(self) -> bool:
"""Returns the is vtherm is in safety mode"""
return self._safety_state == STATE_ON
@property
def safety_state(self) -> str:
"""Returns the safety state: STATE_ON, STATE_OFF, STATE_UNKWNON, STATE_UNAVAILABLE"""
return self._safety_state
@property
def safety_delay_min(self) -> bool:
"""Returns the safety delay min"""
return self._safety_delay_min
@property
def safety_min_on_percent(self) -> bool:
"""Returns the safety min on percent"""
return self._safety_min_on_percent
@property
def safety_default_on_percent(self) -> bool:
"""Returns the safety safety_default_on_percent"""
return self._safety_default_on_percent
def __str__(self):
return f"SafetyManager-{self.name}"

View File

@@ -0,0 +1,546 @@
""" Implements the Window Feature Manager """
# pylint: disable=line-too-long
import logging
from typing import Any
from datetime import timedelta
from homeassistant.const import (
STATE_ON,
STATE_OFF,
STATE_UNAVAILABLE,
STATE_UNKNOWN,
)
from homeassistant.core import (
HomeAssistant,
callback,
Event,
)
from homeassistant.helpers.event import (
async_track_state_change_event,
EventStateChangedData,
async_call_later,
)
from homeassistant.components.climate import HVACMode
from homeassistant.exceptions import ConditionError
from homeassistant.helpers import condition
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
from .commons import ConfigData
from .base_manager import BaseFeatureManager
from .open_window_algorithm import WindowOpenDetectionAlgorithm
_LOGGER = logging.getLogger(__name__)
class FeatureWindowManager(BaseFeatureManager):
"""The implementation of the Window feature"""
unrecorded_attributes = frozenset(
{
"window_sensor_entity_id",
"is_window_configured",
"is_window_bypass",
"window_delay_sec",
"window_auto_configured",
"window_auto_open_threshold",
"window_auto_close_threshold",
"window_auto_max_duration",
"window_action",
}
)
def __init__(self, vtherm: Any, hass: HomeAssistant):
"""Init of a featureManager"""
super().__init__(vtherm, hass)
self._window_sensor_entity_id: str = None
self._window_state: str = STATE_UNAVAILABLE
self._window_auto_open_threshold: float = 0
self._window_auto_close_threshold: float = 0
self._window_auto_max_duration: int = 0
self._window_auto_state: bool = False
self._window_auto_algo: WindowOpenDetectionAlgorithm = None
self._is_window_bypass: bool = False
self._window_action: str = None
self._window_delay_sec: int | None = 0
self._is_configured: bool = False
self._is_window_auto_configured: bool = False
self._window_call_cancel: callable = None
@overrides
def post_init(self, entry_infos: ConfigData):
"""Reinit of the manager"""
self.dearm_window_timer()
self._window_auto_state = STATE_UNAVAILABLE
self._window_state = STATE_UNAVAILABLE
self._window_sensor_entity_id = entry_infos.get(CONF_WINDOW_SENSOR)
self._window_delay_sec = entry_infos.get(CONF_WINDOW_DELAY)
self._window_action = (
entry_infos.get(CONF_WINDOW_ACTION) or CONF_WINDOW_TURN_OFF
)
self._window_auto_open_threshold = entry_infos.get(
CONF_WINDOW_AUTO_OPEN_THRESHOLD
)
self._window_auto_close_threshold = entry_infos.get(
CONF_WINDOW_AUTO_CLOSE_THRESHOLD
)
self._window_auto_max_duration = entry_infos.get(CONF_WINDOW_AUTO_MAX_DURATION)
use_window_feature = entry_infos.get(CONF_USE_WINDOW_FEATURE, False)
if ( # pylint: disable=too-many-boolean-expressions
use_window_feature
and self._window_sensor_entity_id is None
and self._window_auto_open_threshold is not None
and self._window_auto_open_threshold > 0.0
and self._window_auto_close_threshold is not None
and self._window_auto_max_duration is not None
and self._window_auto_max_duration > 0
and self._window_action is not None
):
self._is_window_auto_configured = True
self._window_auto_state = STATE_UNKNOWN
self._window_auto_algo = WindowOpenDetectionAlgorithm(
alert_threshold=self._window_auto_open_threshold,
end_alert_threshold=self._window_auto_close_threshold,
)
if self._is_window_auto_configured or (
use_window_feature
and self._window_sensor_entity_id is not None
and self._window_delay_sec is not None
and self._window_action is not None
):
self._is_configured = True
self._window_state = STATE_UNKNOWN
@overrides
def start_listening(self):
"""Start listening the underlying entity"""
if self._is_configured:
self.stop_listening()
if self._window_sensor_entity_id:
self.add_listener(
async_track_state_change_event(
self.hass,
[self._window_sensor_entity_id],
self._window_sensor_changed,
)
)
@overrides
def stop_listening(self):
"""Stop listening and remove the eventual timer still running"""
self.dearm_window_timer()
super().stop_listening()
def dearm_window_timer(self):
"""Dearm the eventual motion time running"""
if self._window_call_cancel:
self._window_call_cancel()
self._window_call_cancel = None
@overrides
async def refresh_state(self) -> bool:
"""Tries to get the last state from sensor
Returns True if a change has been made"""
ret = False
if self._is_configured and self._window_sensor_entity_id is not None:
window_state = self.hass.states.get(self._window_sensor_entity_id)
if window_state and window_state.state not in (
STATE_UNAVAILABLE,
STATE_UNKNOWN,
):
_LOGGER.debug(
"%s - Window state have been retrieved: %s",
self,
self._window_state,
)
# recalculate the right target_temp in activity mode
ret = await self.update_window_state(window_state.state)
return ret
@callback
async def _window_sensor_changed(self, event: Event[EventStateChangedData]):
"""Handle window sensor changes."""
new_state = event.data.get("new_state")
old_state = event.data.get("old_state")
_LOGGER.info(
"%s - Window changed. Event.new_state is %s, _hvac_mode=%s, _saved_hvac_mode=%s",
self,
new_state,
self._vtherm.hvac_mode,
self._vtherm.saved_hvac_mode,
)
# Check delay condition
async def try_window_condition(_):
try:
long_enough = condition.state(
self._hass,
self._window_sensor_entity_id,
new_state.state,
timedelta(seconds=self._window_delay_sec),
)
except ConditionError:
long_enough = False
if not long_enough:
_LOGGER.debug(
"Window delay condition is not satisfied. Ignore window event"
)
self._window_state = old_state.state or STATE_OFF
return
_LOGGER.debug("%s - Window delay condition is satisfied", self)
if self._window_state == new_state.state:
_LOGGER.debug("%s - no change in window state. Forget the event")
return
_LOGGER.debug("%s - Window ByPass is : %s", self, self._is_window_bypass)
if self._is_window_bypass:
_LOGGER.info(
"%s - Window ByPass is activated. Ignore window event", self
)
# We change tne state but we don't apply the change
self._window_state = new_state.state
else:
await self.update_window_state(new_state.state)
self._vtherm.update_custom_attributes()
if new_state is None or old_state is None or new_state.state == old_state.state:
return try_window_condition
self.dearm_window_timer()
self._window_call_cancel = async_call_later(
self.hass, timedelta(seconds=self._window_delay_sec), try_window_condition
)
# For testing purpose we need to access the inner function
return try_window_condition
async def update_window_state(self, new_state: str = None) -> bool:
"""Change the window detection state.
new_state is on if an open window have been detected or off else
return True if the state have changed
"""
if self._window_state == new_state:
return False
if new_state != STATE_ON:
_LOGGER.info(
"%s - Window is closed. Restoring hvac_mode '%s' if stopped by window detection or temperature %s",
self,
self._vtherm.saved_hvac_mode,
self._vtherm.saved_target_temp,
)
if self._window_action in [
CONF_WINDOW_FROST_TEMP,
CONF_WINDOW_ECO_TEMP,
]:
await self._vtherm.restore_target_temp()
# default to TURN_OFF
elif self._window_action in [CONF_WINDOW_TURN_OFF]:
if (
self._vtherm.last_central_mode != CENTRAL_MODE_STOPPED
and self._vtherm.hvac_off_reason == HVAC_OFF_REASON_WINDOW_DETECTION
):
self._vtherm.set_hvac_off_reason(None)
await self._vtherm.restore_hvac_mode(True)
elif self._window_action in [CONF_WINDOW_FAN_ONLY]:
if self._vtherm.last_central_mode != CENTRAL_MODE_STOPPED:
self._vtherm.set_hvac_off_reason(None)
await self._vtherm.restore_hvac_mode(True)
else:
_LOGGER.error(
"%s - undefined window_action %s. Please open a bug in the github of this project with this log",
self,
self._window_action,
)
return False
else:
_LOGGER.info(
"%s - Window is open. Apply window action %s", self, self._window_action
)
if self._window_action == CONF_WINDOW_TURN_OFF and not self._vtherm.is_on:
_LOGGER.debug(
"%s is already off. Forget turning off VTherm due to window detection"
)
self._window_state = new_state
return False
# self._window_state = new_state
if self._vtherm.last_central_mode in [CENTRAL_MODE_AUTO, None]:
if self._window_action in [
CONF_WINDOW_TURN_OFF,
CONF_WINDOW_FAN_ONLY,
]:
self._vtherm.save_hvac_mode()
elif self._window_action in [
CONF_WINDOW_FROST_TEMP,
CONF_WINDOW_ECO_TEMP,
]:
self._vtherm.save_target_temp()
if (
self._window_action == CONF_WINDOW_FAN_ONLY
and HVACMode.FAN_ONLY in self._vtherm.hvac_modes
):
await self._vtherm.async_set_hvac_mode(HVACMode.FAN_ONLY)
elif (
self._window_action == CONF_WINDOW_FROST_TEMP
and self._vtherm.is_preset_configured(PRESET_FROST_PROTECTION)
):
await self._vtherm.change_target_temperature(
self._vtherm.find_preset_temp(PRESET_FROST_PROTECTION)
)
elif (
self._window_action == CONF_WINDOW_ECO_TEMP
and self._vtherm.is_preset_configured(PRESET_ECO)
):
await self._vtherm.change_target_temperature(
self._vtherm.find_preset_temp(PRESET_ECO)
)
else: # default is to turn_off
self._vtherm.set_hvac_off_reason(HVAC_OFF_REASON_WINDOW_DETECTION)
await self._vtherm.async_set_hvac_mode(HVACMode.OFF)
self._window_state = new_state
return True
async def manage_window_auto(self, in_cycle=False) -> callable:
"""The management of the window auto feature
Returns the dearm function used to deactivate the window auto"""
async def dearm_window_auto(_):
"""Callback that will be called after end of WINDOW_AUTO_MAX_DURATION"""
_LOGGER.info("Unset window auto because MAX_DURATION is exceeded")
await deactivate_window_auto(auto=True)
async def deactivate_window_auto(auto=False):
"""Deactivation of the Window auto state"""
_LOGGER.warning(
"%s - End auto detection of open window slope=%.3f", self, slope
)
# Send an event
cause = "max duration expiration" if auto else "end of slope alert"
self._vtherm.send_event(
EventType.WINDOW_AUTO_EVENT,
{"type": "end", "cause": cause, "curve_slope": slope},
)
# Set attributes
self._window_auto_state = STATE_OFF
await self.update_window_state(self._window_auto_state)
# await self.restore_hvac_mode(True)
self.dearm_window_timer()
if not self._window_auto_algo:
return None
if in_cycle:
slope = self._window_auto_algo.check_age_last_measurement(
temperature=self._vtherm.ema_temperature,
datetime_now=self._vtherm.now,
)
else:
slope = self._window_auto_algo.add_temp_measurement(
temperature=self._vtherm.ema_temperature,
datetime_measure=self._vtherm.last_temperature_measure,
)
_LOGGER.debug(
"%s - Window auto is on, check the alert. last slope is %.3f",
self,
slope if slope is not None else 0.0,
)
if self.is_window_bypass or not self._is_window_auto_configured:
_LOGGER.debug(
"%s - Window auto event is ignored because bypass is ON or window auto detection is disabled",
self,
)
return None
if (
self._window_auto_algo.is_window_open_detected()
and self._window_auto_state in [STATE_UNKNOWN, STATE_OFF]
and self._vtherm.hvac_mode != HVACMode.OFF
):
if (
self._vtherm.proportional_algorithm
and self._vtherm.proportional_algorithm.on_percent <= 0.0
):
_LOGGER.info(
"%s - Start auto detection of open window slope=%.3f but no heating detected (on_percent<=0). Forget the event",
self,
slope,
)
return dearm_window_auto
_LOGGER.warning(
"%s - Start auto detection of open window slope=%.3f", self, slope
)
# Send an event
self._vtherm.send_event(
EventType.WINDOW_AUTO_EVENT,
{"type": "start", "cause": "slope alert", "curve_slope": slope},
)
# Set attributes
self._window_auto_state = STATE_ON
await self.update_window_state(self._window_auto_state)
# Arm the end trigger
self.dearm_window_timer()
self._window_call_cancel = async_call_later(
self.hass,
timedelta(minutes=self._window_auto_max_duration),
dearm_window_auto,
)
elif (
self._window_auto_algo.is_window_close_detected()
and self._window_auto_state == STATE_ON
):
await deactivate_window_auto(False)
# For testing purpose we need to return the inner function
return dearm_window_auto
def add_custom_attributes(self, extra_state_attributes: dict[str, Any]):
"""Add some custom attributes"""
extra_state_attributes.update(
{
"window_state": self.window_state,
"window_auto_state": self.window_auto_state,
"window_action": self.window_action,
"is_window_bypass": self._is_window_bypass,
"window_sensor_entity_id": self._window_sensor_entity_id,
"window_delay_sec": self._window_delay_sec,
"is_window_configured": self._is_configured,
"is_window_auto_configured": self._is_window_auto_configured,
"window_auto_open_threshold": self._window_auto_open_threshold,
"window_auto_close_threshold": self._window_auto_close_threshold,
"window_auto_max_duration": self._window_auto_max_duration,
}
)
async def set_window_bypass(self, window_bypass: bool) -> bool:
"""Set the window bypass flag
Return True if state have been changed"""
self._is_window_bypass = window_bypass
if not self._is_window_bypass and self._window_state:
_LOGGER.info(
"%s - Last window state was open & ByPass is now off. Set hvac_mode to '%s'",
self,
HVACMode.OFF,
)
self._vtherm.save_hvac_mode()
await self._vtherm.async_set_hvac_mode(HVACMode.OFF)
return True
if self._is_window_bypass and self._window_state:
_LOGGER.info(
"%s - Last window state was open & ByPass is now on. Set hvac_mode to last available mode",
self,
)
await self._vtherm.restore_hvac_mode(True)
return True
return False
@overrides
@property
def is_configured(self) -> bool:
"""Return True of the window feature is configured"""
return self._is_configured
@property
def is_window_auto_configured(self) -> bool:
"""Return True of the window automatic detection is configured"""
return self._is_window_auto_configured
@property
def window_state(self) -> str | None:
"""Return the current window state STATE_ON or STATE_OFF
or STATE_UNAVAILABLE if not configured"""
if not self._is_configured:
return STATE_UNAVAILABLE
return self._window_state
@property
def window_auto_state(self) -> str | None:
"""Return the current window auto state STATE_ON or STATE_OFF
or STATE_UNAVAILABLE if not configured"""
if not self._is_configured:
return STATE_UNAVAILABLE
return self._window_auto_state
@property
def is_window_bypass(self) -> str | None:
"""Return True if the window bypass is activated"""
if not self._is_configured:
return False
return self._is_window_bypass
@property
def is_window_detected(self) -> bool:
"""Return true if the presence is configured and presence sensor is OFF"""
return self._is_configured and (
self._window_state == STATE_ON or self._window_auto_state == STATE_ON
)
@property
def window_sensor_entity_id(self) -> bool:
"""Return true if the presence is configured and presence sensor is OFF"""
return self._window_sensor_entity_id
@property
def window_delay_sec(self) -> bool:
"""Return the motion delay"""
return self._window_delay_sec
@property
def window_action(self) -> bool:
"""Return the window action"""
return self._window_action
@property
def window_auto_open_threshold(self) -> bool:
"""Return the window_auto_open_threshold"""
return self._window_auto_open_threshold
@property
def window_auto_close_threshold(self) -> bool:
"""Return the window_auto_close_threshold"""
return self._window_auto_close_threshold
@property
def window_auto_max_duration(self) -> bool:
"""Return the window_auto_max_duration"""
return self._window_auto_max_duration
@property
def last_slope(self) -> float:
"""Return the last slope (in °C/hour)"""
if not self._window_auto_algo:
return None
return self._window_auto_algo.last_slope
def __str__(self):
return f"WindowManager-{self.name}"

View File

@@ -14,6 +14,6 @@
"quality_scale": "silver",
"requirements": [],
"ssdp": [],
"version": "6.8.0",
"version": "7.0.0",
"zeroconf": []
}

View File

@@ -28,7 +28,7 @@ from homeassistant.helpers.entity_platform import AddEntitiesCallback
from homeassistant.util import slugify
from .vtherm_api import VersatileThermostatAPI
from .commons import VersatileThermostatBaseEntity
from .base_entity import VersatileThermostatBaseEntity
from .const import (
DOMAIN,
@@ -367,9 +367,6 @@ class CentralConfigTemperatureNumber(
@property
def native_unit_of_measurement(self) -> str | None:
"""The unit of measurement"""
# TODO Kelvin ? It seems not because all internal values are stored in
# ° Celsius but only the render in front can be in °K depending on the
# user configuration.
return self.hass.config.units.temperature_unit

View File

@@ -187,7 +187,7 @@ class PropAlgorithm:
self._off_time_sec = self._cycle_min * 60 - self._on_time_sec
def set_security(self, default_on_percent: float):
def set_safety(self, default_on_percent: float):
"""Set a default value for on_percent (used for safety mode)"""
_LOGGER.info(
"%s - Proportional Algo - set security to ON", self._vtherm_entity_id
@@ -196,7 +196,7 @@ class PropAlgorithm:
self._default_on_percent = default_on_percent
self._calculate_internal()
def unset_security(self):
def unset_safety(self):
"""Unset the safety mode"""
_LOGGER.info(
"%s - Proportional Algo - set security to OFF", self._vtherm_entity_id

View File

@@ -35,7 +35,7 @@ from homeassistant.components.climate import (
from .base_thermostat import BaseThermostat
from .vtherm_api import VersatileThermostatAPI
from .commons import VersatileThermostatBaseEntity
from .base_entity import VersatileThermostatBaseEntity
from .const import (
DOMAIN,
DEVICE_MANUFACTURER,
@@ -165,7 +165,7 @@ class EnergySensor(VersatileThermostatBaseEntity, SensorEntity):
if not self.my_climate:
return None
if self.my_climate.device_power > THRESHOLD_WATT_KILO:
if self.my_climate.power_manager.device_power > THRESHOLD_WATT_KILO:
return UnitOfEnergy.WATT_HOUR
else:
return UnitOfEnergy.KILO_WATT_HOUR
@@ -190,16 +190,17 @@ class MeanPowerSensor(VersatileThermostatBaseEntity, SensorEntity):
"""Called when my climate have change"""
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
if math.isnan(float(self.my_climate.mean_cycle_power)) or math.isinf(
self.my_climate.mean_cycle_power
):
if math.isnan(
float(self.my_climate.power_manager.mean_cycle_power)
) or math.isinf(self.my_climate.power_manager.mean_cycle_power):
raise ValueError(
f"Sensor has illegal state {self.my_climate.mean_cycle_power}"
f"Sensor has illegal state {self.my_climate.power_manager.mean_cycle_power}"
)
old_state = self._attr_native_value
self._attr_native_value = round(
self.my_climate.mean_cycle_power, self.suggested_display_precision
self.my_climate.power_manager.mean_cycle_power,
self.suggested_display_precision,
)
if old_state != self._attr_native_value:
self.async_write_ha_state()
@@ -222,7 +223,7 @@ class MeanPowerSensor(VersatileThermostatBaseEntity, SensorEntity):
if not self.my_climate:
return None
if self.my_climate.device_power > THRESHOLD_WATT_KILO:
if self.my_climate.power_manager.device_power > THRESHOLD_WATT_KILO:
return UnitOfPower.WATT
else:
return UnitOfPower.KILO_WATT
@@ -644,6 +645,10 @@ class NbActiveDeviceForBoilerSensor(SensorEntity):
"""Representation of the threshold of the number of VTherm
which should be active to activate the boiler"""
_entity_component_unrecorded_attributes = SensorEntity._entity_component_unrecorded_attributes.union( # pylint: disable=protected-access
frozenset({"active_device_ids"})
)
def __init__(self, hass: HomeAssistant, unique_id, name, entry_infos) -> None:
"""Initialize the energy sensor"""
self._hass = hass
@@ -653,6 +658,14 @@ class NbActiveDeviceForBoilerSensor(SensorEntity):
self._attr_unique_id = "nb_device_active_boiler"
self._attr_value = self._attr_native_value = None # default value
self._entities = []
self._attr_active_device_ids = [] # Holds the entity ids of active devices
@property
def extra_state_attributes(self) -> dict:
"""Return additional attributes for the sensor."""
return {
"active_device_ids": self._attr_active_device_ids,
}
@property
def icon(self) -> str | None:
@@ -718,19 +731,19 @@ class NbActiveDeviceForBoilerSensor(SensorEntity):
self.calculate_nb_active_devices,
)
_LOGGER.info(
"%s - the underlyings that could controls the central boiler are %s",
"%s - the underlyings that could control the central boiler are %s",
self,
underlying_entities_id,
)
self.async_on_remove(listener_cancel)
else:
_LOGGER.debug("%s - no VTherm could controls the central boiler", self)
_LOGGER.debug("%s - no VTherm could control the central boiler", self)
await self.calculate_nb_active_devices(None)
async def calculate_nb_active_devices(self, event: Event):
"""Calculate the number of active VTherm that have an
influence on central boiler"""
influence on the central boiler and update the list of active device names."""
# _LOGGER.debug("%s- calculate_nb_active_devices - the event is %s ", self, event)
@@ -757,6 +770,8 @@ class NbActiveDeviceForBoilerSensor(SensorEntity):
old_state is not None
and new_state.state == old_state.state
and new_hvac_action == old_hvac_action
# issue 698 - force recalculation when underlying climate doesn't have any hvac_action
and new_hvac_action is not None
):
# A false state change
return
@@ -774,20 +789,28 @@ class NbActiveDeviceForBoilerSensor(SensorEntity):
)
nb_active = 0
active_device_ids = []
for entity in self._entities:
nb_active += entity.nb_device_actives
device_actives = entity.device_actives
_LOGGER.debug(
"After examining the hvac_action of %s, nb_active is %s",
"After examining the hvac_action of %s, device_actives is %s",
entity.name,
nb_active,
device_actives,
)
nb_active += len(device_actives)
active_device_ids.extend(device_actives)
self._attr_native_value = nb_active
_LOGGER.debug(
"%s - Number of active underlying entities is %s", self, nb_active
)
self._attr_active_device_ids = active_device_ids
self.async_write_ha_state()
@property
def active_device_ids(self) -> list:
"""Get the list of active device id"""
return self._attr_active_device_ids
def __str__(self):
return f"VersatileThermostat-{self.name}"

View File

@@ -76,7 +76,7 @@ set_preset_temperature:
unit_of_measurement: °
mode: slider
set_security:
set_safety:
name: Set safety
description: Change the safety parameters
target:

View File

@@ -192,16 +192,16 @@
"description": "Configuration of advanced parameters. Leave the default values if you don't know what you are doing.\nThese parameters can lead to very poor temperature control or bad power regulation.",
"data": {
"minimal_activation_delay": "Minimum activation delay",
"security_delay_min": "Safety delay (in minutes)",
"security_min_on_percent": "Minimum power percent to enable safety mode",
"security_default_on_percent": "Power percent to use in safety mode",
"safety_delay_min": "Safety delay (in minutes)",
"safety_min_on_percent": "Minimum power percent to enable safety mode",
"safety_default_on_percent": "Power percent to use in safety mode",
"use_advanced_central_config": "Use central advanced configuration"
},
"data_description": {
"minimal_activation_delay": "Delay in seconds under which the equipment will not be activated",
"security_delay_min": "Maximum allowed delay in minutes between two temperature measurements. Above this delay the thermostat will turn to a safety off state",
"security_min_on_percent": "Minimum heating percent value for safety preset activation. Below this amount of power percent the thermostat won't go into safety preset",
"security_default_on_percent": "The default heating power percent value in safety preset. Set to 0 to switch off heater in safety preset",
"safety_delay_min": "Maximum allowed delay in minutes between two temperature measurements. Above this delay the thermostat will turn to a safety off state",
"safety_min_on_percent": "Minimum heating percent value for safety preset activation. Below this amount of power percent the thermostat won't go into safety preset",
"safety_default_on_percent": "The default heating power percent value in safety preset. Set to 0 to switch off heater in safety preset",
"use_advanced_central_config": "Check to use the central advanced configuration. Uncheck to use a specific advanced configuration for this VTherm"
}
},
@@ -224,13 +224,15 @@
"offset_calibration_entity_ids": "Offset calibration entities",
"opening_degree_entity_ids": "Opening degree entities",
"closing_degree_entity_ids": "Closing degree entities",
"proportional_function": "Algorithm"
"proportional_function": "Algorithm",
"min_opening_degrees": "Min opening degrees"
},
"data_description": {
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
"proportional_function": "Algorithm to use (TPI is the only one for now)"
"proportional_function": "Algorithm to use (TPI is the only one for now)",
"min_opening_degrees": "A comma seperated list of minimal opening degrees. Default to 0. Example: 20, 25, 30"
}
}
},
@@ -436,16 +438,16 @@
"description": "Advanced parameters. Leave the default values if you don't know what you are doing.\nThese parameters can lead to very poor temperature control or bad power regulation.",
"data": {
"minimal_activation_delay": "Minimum activation delay",
"security_delay_min": "Safety delay (in minutes)",
"security_min_on_percent": "Minimum power percent to enable safety mode",
"security_default_on_percent": "Power percent to use in safety mode",
"safety_delay_min": "Safety delay (in minutes)",
"safety_min_on_percent": "Minimum power percent to enable safety mode",
"safety_default_on_percent": "Power percent to use in safety mode",
"use_advanced_central_config": "Use central advanced configuration"
},
"data_description": {
"minimal_activation_delay": "Delay in seconds under which the equipment will not be activated",
"security_delay_min": "Maximum allowed delay in minutes between two temperature measurements. Above this delay the thermostat will turn to a safety off state",
"security_min_on_percent": "Minimum heating percent value for safety preset activation. Below this amount of power percent the thermostat won't go into safety preset",
"security_default_on_percent": "The default heating power percent value in safety preset. Set to 0 to switch off heater in safety preset",
"safety_delay_min": "Maximum allowed delay in minutes between two temperature measurements. Above this delay the thermostat will turn to a safety off state",
"safety_min_on_percent": "Minimum heating percent value for safety preset activation. Below this amount of power percent the thermostat won't go into safety preset",
"safety_default_on_percent": "The default heating power percent value in safety preset. Set to 0 to switch off heater in safety preset",
"use_advanced_central_config": "Check to use the central advanced configuration. Uncheck to use a specific advanced configuration for this VTherm"
}
},
@@ -468,13 +470,15 @@
"offset_calibration_entity_ids": "Offset calibration entities",
"opening_degree_entity_ids": "Opening degree entities",
"closing_degree_entity_ids": "Closing degree entities",
"proportional_function": "Algorithm"
"proportional_function": "Algorithm",
"min_opening_degrees": "Min opening degrees"
},
"data_description": {
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
"proportional_function": "Algorithm to use (TPI is the only one for now)"
"proportional_function": "Algorithm to use (TPI is the only one for now)",
"min_opening_degrees": "A comma seperated list of minimal opening degrees. Default to 0. Example: 20, 25, 30"
}
}
},
@@ -484,7 +488,8 @@
"window_open_detection_method": "Only one window open detection method should be used. Use either window sensor or automatic detection through temperature threshold but not both",
"no_central_config": "You cannot check 'use central configuration' because no central configuration was found. You need to create a Versatile Thermostat of type 'Central Configuration' to use it.",
"service_configuration_format": "The format of the service configuration is wrong",
"valve_regulation_nb_entities_incorrect": "The number of valve entities for valve regulation should be equal to the number of underlyings"
"valve_regulation_nb_entities_incorrect": "The number of valve entities for valve regulation should be equal to the number of underlyings",
"min_opening_degrees_format": "A comma separated list of positive integer is expected. Example: 20, 25, 30"
},
"abort": {
"already_configured": "Device is already configured"

View File

@@ -12,7 +12,7 @@ from homeassistant.config_entries import ConfigEntry
from homeassistant.helpers.restore_state import RestoreEntity
from homeassistant.helpers.entity_platform import AddEntitiesCallback
from .commons import VersatileThermostatBaseEntity
from .base_entity import VersatileThermostatBaseEntity
from .const import * # pylint: disable=unused-wildcard-import,wildcard-import
@@ -84,8 +84,13 @@ class AutoStartStopEnable(VersatileThermostatBaseEntity, SwitchEntity, RestoreEn
def update_my_state_and_vtherm(self):
"""Update the auto_start_stop_enable flag in my VTherm"""
self.async_write_ha_state()
if self.my_climate is not None:
self.my_climate.set_auto_start_stop_enable(self._attr_is_on)
if (
self.my_climate is not None
and self.my_climate.auto_start_stop_manager is not None
):
self.my_climate.auto_start_stop_manager.set_auto_start_stop_enable(
self._attr_is_on
)
@callback
async def async_turn_on(self, **kwargs: Any) -> None:

View File

@@ -24,11 +24,7 @@ from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
from .vtherm_api import VersatileThermostatAPI
from .underlyings import UnderlyingClimate
from .auto_start_stop_algorithm import (
AutoStartStopDetectionAlgorithm,
AUTO_START_STOP_ACTION_OFF,
AUTO_START_STOP_ACTION_ON,
)
from .feature_auto_start_stop_manager import FeatureAutoStartStopManager
_LOGGER = logging.getLogger(__name__)
@@ -55,15 +51,9 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
"auto_activated_fan_mode",
"auto_deactivated_fan_mode",
"auto_regulation_use_device_temp",
"auto_start_stop_level",
"auto_start_stop_dtmin",
"auto_start_stop_enable",
"auto_start_stop_accumulated_error",
"auto_start_stop_accumulated_error_threshold",
"auto_start_stop_last_switch_date",
"follow_underlying_temp_change",
}
)
).union(FeatureAutoStartStopManager.unrecorded_attributes)
)
def __init__(
@@ -83,11 +73,6 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
# The fan_mode name depending of the current_mode
self._auto_activated_fan_mode: str | None = None
self._auto_deactivated_fan_mode: str | None = None
self._auto_start_stop_level: TYPE_AUTO_START_STOP_LEVELS = (
AUTO_START_STOP_LEVEL_NONE
)
self._auto_start_stop_algo: AutoStartStopDetectionAlgorithm | None = None
self._is_auto_start_stop_enabled: bool = False
self._follow_underlying_temp_change: bool = False
self._last_regulation_change = None # NowClass.get_now(hass)
@@ -99,6 +84,12 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
def post_init(self, config_entry: ConfigData):
"""Initialize the Thermostat"""
self._auto_start_stop_manager: FeatureAutoStartStopManager = (
FeatureAutoStartStopManager(self, self._hass)
)
self.register_manager(self._auto_start_stop_manager)
super().post_init(config_entry)
for climate in config_entry.get(CONF_UNDERLYING_LIST):
@@ -136,19 +127,6 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
CONF_AUTO_REGULATION_USE_DEVICE_TEMP, False
)
use_auto_start_stop = config_entry.get(CONF_USE_AUTO_START_STOP_FEATURE, False)
if use_auto_start_stop:
self._auto_start_stop_level = config_entry.get(
CONF_AUTO_START_STOP_LEVEL, AUTO_START_STOP_LEVEL_NONE
)
else:
self._auto_start_stop_level = AUTO_START_STOP_LEVEL_NONE
# Instanciate the auto start stop algo
self._auto_start_stop_algo = AutoStartStopDetectionAlgorithm(
self._auto_start_stop_level, self.name
)
@property
def is_over_climate(self) -> bool:
"""True if the Thermostat is over_climate"""
@@ -178,13 +156,13 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
return self.calculate_hvac_action(self._underlyings)
@overrides
async def _async_internal_set_temperature(self, temperature: float):
async def change_target_temperature(self, temperature: float):
"""Set the target temperature and the target temperature of underlying climate if any"""
await super()._async_internal_set_temperature(temperature)
await super().change_target_temperature(temperature)
self._regulation_algo.set_target_temp(self.target_temperature)
# is done by control_heating method. No need to do it here
# await self._send_regulated_temperature(force=True)
# Is necessary cause control_heating method will not force the update.
await self._send_regulated_temperature(force=True)
async def _send_regulated_temperature(self, force=False):
"""Sends the regulated temperature to all underlying"""
@@ -538,28 +516,6 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
self.auto_regulation_use_device_temp
)
self._attr_extra_state_attributes["auto_start_stop_enable"] = (
self.auto_start_stop_enable
)
self._attr_extra_state_attributes["auto_start_stop_level"] = (
self._auto_start_stop_algo.level
)
self._attr_extra_state_attributes["auto_start_stop_dtmin"] = (
self._auto_start_stop_algo.dt_min
)
self._attr_extra_state_attributes["auto_start_stop_accumulated_error"] = (
self._auto_start_stop_algo.accumulated_error
)
self._attr_extra_state_attributes[
"auto_start_stop_accumulated_error_threshold"
] = self._auto_start_stop_algo.accumulated_error_threshold
self._attr_extra_state_attributes["auto_start_stop_last_switch_date"] = (
self._auto_start_stop_algo.last_switch_date
)
self._attr_extra_state_attributes["follow_underlying_temp_change"] = (
self._follow_underlying_temp_change
)
@@ -593,7 +549,7 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
_LOGGER.info(
"%s - Force resent target temp cause we turn on some over climate"
)
await self._async_internal_set_temperature(self._target_temp)
await self.change_target_temperature(self._target_temp)
@overrides
def incremente_energy(self):
@@ -602,13 +558,14 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
if self.hvac_mode == HVACMode.OFF:
return
device_power = self.power_manager.device_power
added_energy = 0
if (
self.is_over_climate
and self._underlying_climate_delta_t is not None
and self._device_power
and device_power
):
added_energy = self._device_power * self._underlying_climate_delta_t
added_energy = device_power * self._underlying_climate_delta_t
if self._total_energy is None:
self._total_energy = added_energy
@@ -709,7 +666,9 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
under_temp_diff = (
(new_target_temp - last_sent_temperature) if new_target_temp else 0
)
if -1 < under_temp_diff < 1:
step = self.target_temperature_step or 1
if -step < under_temp_diff < step:
under_temp_diff = 0
# Issue 99 - some AC turn hvac_mode=cool and hvac_action=idle when sending a HVACMode_OFF command
@@ -766,7 +725,7 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
_LOGGER.debug(
"%s - last_change_time=%s old_state_date_changed=%s old_state_date_updated=%s new_state_date_changed=%s new_state_date_updated=%s",
self,
self._last_change_time,
self._last_change_time_from_vtherm,
old_state_date_changed,
old_state_date_updated,
new_state_date_changed,
@@ -809,8 +768,10 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
# Filter new state when received just after a change from VTherm
# Issue #120 - Some TRV are changing target temperature a very long time (6 sec) after the change.
# In that case a loop is possible if a user change multiple times during this 6 sec.
if new_state_date_updated and self._last_change_time:
delta = (new_state_date_updated - self._last_change_time).total_seconds()
if new_state_date_updated and self._last_change_time_from_vtherm:
delta = (
new_state_date_updated - self._last_change_time_from_vtherm
).total_seconds()
if delta < 10:
_LOGGER.info(
"%s - underlying event is received less than 10 sec after command. Forget it to avoid loop",
@@ -894,90 +855,17 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
await end_climate_changed(changes)
async def check_auto_start_stop(self):
"""Check the auto-start-stop and an eventual action
Return False if we should stop the control_heating method"""
slope = (self.last_temperature_slope or 0) / 60 # to have the slope in °/min
action = self._auto_start_stop_algo.calculate_action(
self.hvac_mode,
self._saved_hvac_mode,
self.target_temperature,
self.current_temperature,
slope,
self.now,
)
_LOGGER.debug("%s - auto_start_stop action is %s", self, action)
if action == AUTO_START_STOP_ACTION_OFF and self.is_on:
_LOGGER.info(
"%s - Turning OFF the Vtherm due to auto-start-stop conditions",
self,
)
self.set_hvac_off_reason(HVAC_OFF_REASON_AUTO_START_STOP)
await self.async_turn_off()
# Send an event
self.send_event(
event_type=EventType.AUTO_START_STOP_EVENT,
data={
"type": "stop",
"name": self.name,
"cause": "Auto stop conditions reached",
"hvac_mode": self.hvac_mode,
"saved_hvac_mode": self._saved_hvac_mode,
"target_temperature": self.target_temperature,
"current_temperature": self.current_temperature,
"temperature_slope": round(slope, 3),
"accumulated_error": self._auto_start_stop_algo.accumulated_error,
"accumulated_error_threshold": self._auto_start_stop_algo.accumulated_error_threshold,
},
)
# Stop here
return False
elif (
action == AUTO_START_STOP_ACTION_ON
and self.hvac_off_reason == HVAC_OFF_REASON_AUTO_START_STOP
):
_LOGGER.info(
"%s - Turning ON the Vtherm due to auto-start-stop conditions", self
)
await self.async_turn_on()
# Send an event
self.send_event(
event_type=EventType.AUTO_START_STOP_EVENT,
data={
"type": "start",
"name": self.name,
"cause": "Auto start conditions reached",
"hvac_mode": self.hvac_mode,
"saved_hvac_mode": self._saved_hvac_mode,
"target_temperature": self.target_temperature,
"current_temperature": self.current_temperature,
"temperature_slope": round(slope, 3),
"accumulated_error": self._auto_start_stop_algo.accumulated_error,
"accumulated_error_threshold": self._auto_start_stop_algo.accumulated_error_threshold,
},
)
self.update_custom_attributes()
return True
@overrides
async def async_control_heating(self, force=False, _=None) -> bool:
"""The main function used to run the calculation at each cycle"""
ret = await super().async_control_heating(force, _)
# Check if we need to auto start/stop the Vtherm
if self.auto_start_stop_enable:
continu = await self.check_auto_start_stop()
if not continu:
return ret
else:
_LOGGER.debug("%s - auto start/stop is disabled", self)
continu = await self.auto_start_stop_manager.refresh_state()
if not continu:
return ret
# Continue the normal async_control_heating
# Continue the normal async_control_heating
# Send the regulated temperature to the underlyings
await self._send_regulated_temperature()
@@ -987,37 +875,6 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
return ret
def set_auto_start_stop_enable(self, is_enabled: bool):
"""Enable/Disable the auto-start/stop feature"""
self._is_auto_start_stop_enabled = is_enabled
if (
self.hvac_mode == HVACMode.OFF
and self.hvac_off_reason == HVAC_OFF_REASON_AUTO_START_STOP
):
_LOGGER.debug(
"%s - the vtherm is off cause auto-start/stop and enable have been set to false -> starts the VTherm"
)
self.hass.create_task(self.async_turn_on())
# Send an event
self.send_event(
event_type=EventType.AUTO_START_STOP_EVENT,
data={
"type": "start",
"name": self.name,
"cause": "Auto start stop disabled",
"hvac_mode": self.hvac_mode,
"saved_hvac_mode": self._saved_hvac_mode,
"target_temperature": self.target_temperature,
"current_temperature": self.current_temperature,
"temperature_slope": round(self.last_temperature_slope or 0, 3),
"accumulated_error": self._auto_start_stop_algo.accumulated_error,
"accumulated_error_threshold": self._auto_start_stop_algo.accumulated_error_threshold,
},
)
self.update_custom_attributes()
def set_follow_underlying_temp_change(self, follow: bool):
"""Set the flaf follow the underlying temperature changes"""
self._follow_underlying_temp_change = follow
@@ -1168,21 +1025,16 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
return False
return True
@property
def auto_start_stop_level(self) -> TYPE_AUTO_START_STOP_LEVELS:
"""Return the auto start/stop level."""
return self._auto_start_stop_level
@property
def auto_start_stop_enable(self) -> bool:
"""Returns the auto_start_stop_enable"""
return self._is_auto_start_stop_enabled
@property
def follow_underlying_temp_change(self) -> bool:
"""Get the follow underlying temp change flag"""
return self._follow_underlying_temp_change
@property
def auto_start_stop_manager(self) -> FeatureAutoStartStopManager:
"""Return the auto-start-stop Manager"""
return self._auto_start_stop_manager
@overrides
def init_underlyings(self):
"""Init the underlyings if not already done"""

View File

@@ -37,6 +37,7 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
"tpi_coef_int",
"tpi_coef_ext",
"power_percent",
"min_opening_degrees",
}
)
)
@@ -51,6 +52,7 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
self._last_calculation_timestamp: datetime | None = None
self._auto_regulation_dpercent: float | None = None
self._auto_regulation_period_min: int | None = None
self._min_opening_degress: list[int] = []
super().__init__(hass, unique_id, name, entry_infos)
@@ -86,6 +88,14 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
offset_list = config_entry.get(CONF_OFFSET_CALIBRATION_LIST, [])
opening_list = config_entry.get(CONF_OPENING_DEGREE_LIST)
closing_list = config_entry.get(CONF_CLOSING_DEGREE_LIST, [])
self._min_opening_degrees = config_entry.get(CONF_MIN_OPENING_DEGREES, None)
min_opening_degrees_list = []
if self._min_opening_degrees:
min_opening_degrees_list = [
int(x.strip()) for x in self._min_opening_degrees.split(",")
]
for idx, _ in enumerate(config_entry.get(CONF_UNDERLYING_LIST)):
offset = offset_list[idx] if idx < len(offset_list) else None
# number of opening should equal number of underlying
@@ -98,6 +108,11 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
opening_degree_entity_id=opening,
closing_degree_entity_id=closing,
climate_underlying=self._underlyings[idx],
min_opening_degree=(
min_opening_degrees_list[idx]
if idx < len(min_opening_degrees_list)
else 0
),
)
self._underlyings_valve_regulation.append(under)
@@ -130,6 +145,10 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
self._attr_extra_state_attributes["tpi_coef_int"] = self._tpi_coef_int
self._attr_extra_state_attributes["tpi_coef_ext"] = self._tpi_coef_ext
self._attr_extra_state_attributes["min_opening_degrees"] = (
self._min_opening_degrees
)
self._attr_extra_state_attributes["valve_open_percent"] = (
self.valve_open_percent
)
@@ -277,12 +296,15 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
return self.valve_open_percent > 0
@property
def nb_device_actives(self) -> int:
def device_actives(self) -> int:
"""Calculate the number of active devices"""
if self.is_device_active:
return len(self._underlyings_valve_regulation)
return [
under.opening_degree_entity_id
for under in self._underlyings_valve_regulation
]
else:
return 0
return []
@property
def activable_underlying_entities(self) -> list | None:

View File

@@ -182,8 +182,10 @@ class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
return
added_energy = 0
if not self.is_over_climate and self.mean_cycle_power is not None:
added_energy = self.mean_cycle_power * float(self._cycle_min) / 60.0
if not self.is_over_climate and self.power_manager.mean_cycle_power is not None:
added_energy = (
self.power_manager.mean_cycle_power * float(self._cycle_min) / 60.0
)
if self._total_energy is None:
self._total_energy = added_energy

View File

@@ -265,8 +265,10 @@ class ThermostatOverValve(BaseThermostat[UnderlyingValve]): # pylint: disable=a
return
added_energy = 0
if not self.is_over_climate and self.mean_cycle_power is not None:
added_energy = self.mean_cycle_power * float(self._cycle_min) / 60.0
if not self.is_over_climate and self.power_manager.mean_cycle_power is not None:
added_energy = (
self.power_manager.mean_cycle_power * float(self._cycle_min) / 60.0
)
if self._total_energy is None:
self._total_energy = added_energy

View File

@@ -152,15 +152,15 @@
"description": "Διαμόρφωση των προχωρημένων παραμέτρων. Αφήστε τις προεπιλεγμένες τιμές αν δεν γνωρίζετε τι κάνετε.\nΑυτές οι παράμετροι μπορούν να οδηγήσουν σε πολύ κακή ρύθμιση θερμοκρασίας ή ενέργειας.",
"data": {
"minimal_activation_delay": "Ελάχιστη καθυστέρηση ενεργοποίησης",
"security_delay_min": "Καθυστέρηση ασφαλείας (σε λεπτά)",
"security_min_on_percent": "Ελάχιστο ποσοστό ισχύος για ενεργοποίηση λειτουργίας ασφαλείας",
"security_default_on_percent": "Ποσοστό ισχύος για χρήση σε λειτουργία ασφαλείας"
"safety_delay_min": "Καθυστέρηση ασφαλείας (σε λεπτά)",
"safety_min_on_percent": "Ελάχιστο ποσοστό ισχύος για ενεργοποίηση λειτουργίας ασφαλείας",
"safety_default_on_percent": "Ποσοστό ισχύος για χρήση σε λειτουργία ασφαλείας"
},
"data_description": {
"minimal_activation_delay": "Καθυστέρηση σε δευτερόλεπτα κάτω από την οποία η συσκευή δεν θα ενεργοποιηθεί",
"security_delay_min": "Μέγιστη επιτρεπτή καθυστέρηση σε λεπτά μεταξύ δύο μετρήσεων θερμοκρασίας. Πέρα από αυτή την καθυστέρηση, ο θερμοστάτης θα μεταβεί σε κατάσταση ασφαλείας",
"security_min_on_percent": "Ελάχιστη τιμή ποσοστού θέρμανσης για την ενεργοποίηση του προεπιλεγμένου ασφάλειας. Κάτω από αυτό το ποσοστό ισχύος το θερμοστάτη δεν θα πάει στο προεπιλεγμένο ασφάλειας.",
"security_default_on_percent": "Η προεπιλεγμένη τιμή ποσοστού ισχύος θέρμανσης στο προεπιλεγμένο ασφάλειας. Ορίστε σε 0 για να απενεργοποιήσετε τη θερμάστρα στο παρόν ασφάλειας."
"safety_delay_min": "Μέγιστη επιτρεπτή καθυστέρηση σε λεπτά μεταξύ δύο μετρήσεων θερμοκρασίας. Πέρα από αυτή την καθυστέρηση, ο θερμοστάτης θα μεταβεί σε κατάσταση ασφαλείας",
"safety_min_on_percent": "Ελάχιστη τιμή ποσοστού θέρμανσης για την ενεργοποίηση του προεπιλεγμένου ασφάλειας. Κάτω από αυτό το ποσοστό ισχύος το θερμοστάτη δεν θα πάει στο προεπιλεγμένο ασφάλειας.",
"safety_default_on_percent": "Η προεπιλεγμένη τιμή ποσοστού ισχύος θέρμανσης στο προεπιλεγμένο ασφάλειας. Ορίστε σε 0 για να απενεργοποιήσετε τη θερμάστρα στο παρόν ασφάλειας."
}
}
},
@@ -325,15 +325,15 @@
"description": "Διαμόρφωση των προηγμένων παραμέτρων. Αφήστε τις προεπιλεγμένες τιμές εάν δεν γνωρίζετε τι κάνετε.\nΑυτές οι παράμετροι μπορούν να οδηγήσουν σε πολύ κακή ρύθμιση θερμοκρασίας ή ενέργειας.",
"data": {
"minimal_activation_delay": "Ελάχιστη καθυστέρηση ενεργοποίησης",
"security_delay_min": "Καθυστέρηση ασφαλείας (σε λεπτά)",
"security_min_on_percent": "Ελάχιστο ποσοστό ισχύος για τη λειτουργία ασφαλείας",
"security_default_on_percent": "Ποσοστό ισχύος που θα χρησιμοποιηθεί στη λειτουργία ασφαλείας"
"safety_delay_min": "Καθυστέρηση ασφαλείας (σε λεπτά)",
"safety_min_on_percent": "Ελάχιστο ποσοστό ισχύος για τη λειτουργία ασφαλείας",
"safety_default_on_percent": "Ποσοστό ισχύος που θα χρησιμοποιηθεί στη λειτουργία ασφαλείας"
},
"data_description": {
"minimal_activation_delay": "Καθυστέρηση σε δευτερόλεπτα κάτω από την οποία ο εξοπλισμός δεν θα ενεργοποιηθεί",
"security_delay_min": "Μέγιστη επιτρεπόμενη καθυστέρηση σε λεπτά μεταξύ δύο μετρήσεων θερμοκρασίας. Πάνω από αυτή την καθυστέρηση, ο θερμοστάτης θα μεταβεί σε κατάσταση ασφαλείας",
"security_min_on_percent": "Ελάχιστη τιμή ποσοστού θέρμανσης για ενεργοποίηση του προεπιλεγμένου ασφαλείας. Κάτω από αυτό το ποσοστό ισχύος, ο θερμοστάτης δεν θα μεταβεί στο προεπιλεγμένο ασφαλείας",
"security_default_on_percent": "Η προεπιλεγμένη τιμή ποσοστού ισχύος θέρμανσης στο προεπιλεγμένο ασφαλείας. Ορίστε σε 0 για να απενεργοποιήσετε τη θερμάστρα στο παρόν ασφαλείας"
"safety_delay_min": "Μέγιστη επιτρεπόμενη καθυστέρηση σε λεπτά μεταξύ δύο μετρήσεων θερμοκρασίας. Πάνω από αυτή την καθυστέρηση, ο θερμοστάτης θα μεταβεί σε κατάσταση ασφαλείας",
"safety_min_on_percent": "Ελάχιστη τιμή ποσοστού θέρμανσης για ενεργοποίηση του προεπιλεγμένου ασφαλείας. Κάτω από αυτό το ποσοστό ισχύος, ο θερμοστάτης δεν θα μεταβεί στο προεπιλεγμένο ασφαλείας",
"safety_default_on_percent": "Η προεπιλεγμένη τιμή ποσοστού ισχύος θέρμανσης στο προεπιλεγμένο ασφαλείας. Ορίστε σε 0 για να απενεργοποιήσετε τη θερμάστρα στο παρόν ασφαλείας"
}
}
},

View File

@@ -192,16 +192,16 @@
"description": "Configuration of advanced parameters. Leave the default values if you don't know what you are doing.\nThese parameters can lead to very poor temperature control or bad power regulation.",
"data": {
"minimal_activation_delay": "Minimum activation delay",
"security_delay_min": "Safety delay (in minutes)",
"security_min_on_percent": "Minimum power percent to enable safety mode",
"security_default_on_percent": "Power percent to use in safety mode",
"safety_delay_min": "Safety delay (in minutes)",
"safety_min_on_percent": "Minimum power percent to enable safety mode",
"safety_default_on_percent": "Power percent to use in safety mode",
"use_advanced_central_config": "Use central advanced configuration"
},
"data_description": {
"minimal_activation_delay": "Delay in seconds under which the equipment will not be activated",
"security_delay_min": "Maximum allowed delay in minutes between two temperature measurements. Above this delay the thermostat will turn to a safety off state",
"security_min_on_percent": "Minimum heating percent value for safety preset activation. Below this amount of power percent the thermostat won't go into safety preset",
"security_default_on_percent": "The default heating power percent value in safety preset. Set to 0 to switch off heater in safety preset",
"safety_delay_min": "Maximum allowed delay in minutes between two temperature measurements. Above this delay the thermostat will turn to a safety off state",
"safety_min_on_percent": "Minimum heating percent value for safety preset activation. Below this amount of power percent the thermostat won't go into safety preset",
"safety_default_on_percent": "The default heating power percent value in safety preset. Set to 0 to switch off heater in safety preset",
"use_advanced_central_config": "Check to use the central advanced configuration. Uncheck to use a specific advanced configuration for this VTherm"
}
},
@@ -224,13 +224,15 @@
"offset_calibration_entity_ids": "Offset calibration entities",
"opening_degree_entity_ids": "Opening degree entities",
"closing_degree_entity_ids": "Closing degree entities",
"proportional_function": "Algorithm"
"proportional_function": "Algorithm",
"min_opening_degrees": "Min opening degrees"
},
"data_description": {
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
"proportional_function": "Algorithm to use (TPI is the only one for now)"
"proportional_function": "Algorithm to use (TPI is the only one for now)",
"min_opening_degrees": "A comma seperated list of minimal opening degrees. Default to 0. Example: 20, 25, 30"
}
}
},
@@ -436,16 +438,16 @@
"description": "Advanced parameters. Leave the default values if you don't know what you are doing.\nThese parameters can lead to very poor temperature control or bad power regulation.",
"data": {
"minimal_activation_delay": "Minimum activation delay",
"security_delay_min": "Safety delay (in minutes)",
"security_min_on_percent": "Minimum power percent to enable safety mode",
"security_default_on_percent": "Power percent to use in safety mode",
"safety_delay_min": "Safety delay (in minutes)",
"safety_min_on_percent": "Minimum power percent to enable safety mode",
"safety_default_on_percent": "Power percent to use in safety mode",
"use_advanced_central_config": "Use central advanced configuration"
},
"data_description": {
"minimal_activation_delay": "Delay in seconds under which the equipment will not be activated",
"security_delay_min": "Maximum allowed delay in minutes between two temperature measurements. Above this delay the thermostat will turn to a safety off state",
"security_min_on_percent": "Minimum heating percent value for safety preset activation. Below this amount of power percent the thermostat won't go into safety preset",
"security_default_on_percent": "The default heating power percent value in safety preset. Set to 0 to switch off heater in safety preset",
"safety_delay_min": "Maximum allowed delay in minutes between two temperature measurements. Above this delay the thermostat will turn to a safety off state",
"safety_min_on_percent": "Minimum heating percent value for safety preset activation. Below this amount of power percent the thermostat won't go into safety preset",
"safety_default_on_percent": "The default heating power percent value in safety preset. Set to 0 to switch off heater in safety preset",
"use_advanced_central_config": "Check to use the central advanced configuration. Uncheck to use a specific advanced configuration for this VTherm"
}
},
@@ -468,13 +470,15 @@
"offset_calibration_entity_ids": "Offset calibration entities",
"opening_degree_entity_ids": "Opening degree entities",
"closing_degree_entity_ids": "Closing degree entities",
"proportional_function": "Algorithm"
"proportional_function": "Algorithm",
"min_opening_degrees": "Min opening degrees"
},
"data_description": {
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
"proportional_function": "Algorithm to use (TPI is the only one for now)"
"proportional_function": "Algorithm to use (TPI is the only one for now)",
"min_opening_degrees": "A comma seperated list of minimal opening degrees. Default to 0. Example: 20, 25, 30"
}
}
},

View File

@@ -192,16 +192,16 @@
"description": "Configuration des paramètres avancés. Laissez les valeurs par défaut si vous ne savez pas ce que vous faites.\nCes paramètres peuvent induire des mauvais comportements du thermostat.",
"data": {
"minimal_activation_delay": "Délai minimal d'activation",
"security_delay_min": "Délai maximal entre 2 mesures de températures",
"security_min_on_percent": "Pourcentage minimal de puissance",
"security_default_on_percent": "Pourcentage de puissance a utiliser en mode securité",
"safety_delay_min": "Délai maximal entre 2 mesures de températures",
"safety_min_on_percent": "Pourcentage minimal de puissance",
"safety_default_on_percent": "Pourcentage de puissance a utiliser en mode securité",
"use_advanced_central_config": "Utiliser la configuration centrale avancée"
},
"data_description": {
"minimal_activation_delay": "Délai en seondes en-dessous duquel l'équipement ne sera pas activé",
"security_delay_min": "Délai maximal autorisé en minutes entre 2 mesures de températures. Au-dessus de ce délai, le thermostat se mettra en position de sécurité",
"security_min_on_percent": "Seuil minimal de pourcentage de chauffage en-dessous duquel le préréglage sécurité ne sera jamais activé",
"security_default_on_percent": "Valeur par défaut pour le pourcentage de chauffage en mode sécurité. Mettre 0 pour éteindre le radiateur en mode sécurité",
"safety_delay_min": "Délai maximal autorisé en minutes entre 2 mesures de températures. Au-dessus de ce délai, le thermostat se mettra en position de sécurité",
"safety_min_on_percent": "Seuil minimal de pourcentage de chauffage en-dessous duquel le préréglage sécurité ne sera jamais activé",
"safety_default_on_percent": "Valeur par défaut pour le pourcentage de chauffage en mode sécurité. Mettre 0 pour éteindre le radiateur en mode sécurité",
"use_advanced_central_config": "Cochez pour utiliser la configuration centrale avancée. Décochez et saisissez les attributs pour utiliser une configuration spécifique avancée"
}
},
@@ -218,19 +218,21 @@
}
},
"valve_regulation": {
"title": "Auto-régulation par vanne - {name}",
"title": "Auto-régulation par vanne",
"description": "Configuration de l'auto-régulation par controle direct de la vanne",
"data": {
"offset_calibration_entity_ids": "Entités de 'calibrage du décalage''",
"opening_degree_entity_ids": "Entités 'ouverture de vanne'",
"closing_degree_entity_ids": "Entités 'fermeture de la vanne'",
"proportional_function": "Algorithme"
"proportional_function": "Algorithme",
"min_opening_degrees": "Ouvertures minimales"
},
"data_description": {
"offset_calibration_entity_ids": "La liste des entités 'calibrage du décalage' (offset calibration). Configurez le si votre TRV possède cette fonction pour une meilleure régulation. Il doit y en avoir une par entité climate sous-jacente",
"opening_degree_entity_ids": "La liste des entités 'ouverture de vanne'. Il doit y en avoir une par entité climate sous-jacente",
"closing_degree_entity_ids": "La liste des entités 'fermeture de la vanne'. Configurez le si votre TRV possède cette fonction pour une meilleure régulation. Il doit y en avoir une par entité climate sous-jacente",
"proportional_function": "Algorithme à utiliser (seulement TPI est disponible)"
"proportional_function": "Algorithme à utiliser (seulement TPI est disponible)",
"min_opening_degrees": "Une liste séparée par des virgules de minimum d'ouverture. Valeur par défaut : 0. Exemple : 20, 25, 30"
}
}
},
@@ -257,7 +259,7 @@
}
},
"menu": {
"title": "Menu - {name}",
"title": "Menu",
"description": "Paramétrez votre thermostat. Vous pourrez finaliser la configuration quand tous les paramètres auront été saisis.",
"menu_options": {
"main": "Principaux Attributs",
@@ -430,16 +432,16 @@
"description": "Paramètres avancés. Laissez les valeurs par défaut si vous ne savez pas ce que vous faites.\nCes paramètres peuvent induire des mauvais comportements du thermostat.",
"data": {
"minimal_activation_delay": "Délai minimal d'activation",
"security_delay_min": "Délai maximal entre 2 mesures de températures",
"security_min_on_percent": "Pourcentage minimal de puissance",
"security_default_on_percent": "Pourcentage de puissance a utiliser en mode securité",
"safety_delay_min": "Délai maximal entre 2 mesures de températures",
"safety_min_on_percent": "Pourcentage minimal de puissance",
"safety_default_on_percent": "Pourcentage de puissance a utiliser en mode securité",
"use_advanced_central_config": "Utiliser la configuration centrale avancée"
},
"data_description": {
"minimal_activation_delay": "Délai en seondes en-dessous duquel l'équipement ne sera pas activé",
"security_delay_min": "Délai maximal autorisé en minutes entre 2 mesures de températures. Au-dessus de ce délai, le thermostat se mettra en position de sécurité",
"security_min_on_percent": "Seuil minimal de pourcentage de chauffage en-dessous duquel le préréglage sécurité ne sera jamais activé",
"security_default_on_percent": "Valeur par défaut pour le pourcentage de chauffage en mode sécurité. Mettre 0 pour éteindre le radiateur en mode sécurité",
"safety_delay_min": "Délai maximal autorisé en minutes entre 2 mesures de températures. Au-dessus de ce délai, le thermostat se mettra en position de sécurité",
"safety_min_on_percent": "Seuil minimal de pourcentage de chauffage en-dessous duquel le préréglage sécurité ne sera jamais activé",
"safety_default_on_percent": "Valeur par défaut pour le pourcentage de chauffage en mode sécurité. Mettre 0 pour éteindre le radiateur en mode sécurité",
"use_advanced_central_config": "Cochez pour utiliser la configuration centrale avancée. Décochez et saisissez les attributs pour utiliser une configuration spécifique avancée"
}
},
@@ -462,13 +464,15 @@
"offset_calibration_entity_ids": "Entités de 'calibrage du décalage''",
"opening_degree_entity_ids": "Entités 'ouverture de vanne'",
"closing_degree_entity_ids": "Entités 'fermeture de la vanne'",
"proportional_function": "Algorithme"
"proportional_function": "Algorithme",
"min_opening_degrees": "Ouvertures minimales"
},
"data_description": {
"offset_calibration_entity_ids": "La liste des entités 'calibrage du décalage' (offset calibration). Configurez le si votre TRV possède cette fonction pour une meilleure régulation. Il doit y en avoir une par entité climate sous-jacente",
"opening_degree_entity_ids": "La liste des entités 'ouverture de vanne'. Il doit y en avoir une par entité climate sous-jacente",
"closing_degree_entity_ids": "La liste des entités 'fermeture de la vanne'. Configurez le si votre TRV possède cette fonction pour une meilleure régulation. Il doit y en avoir une par entité climate sous-jacente",
"proportional_function": "Algorithme à utiliser (seulement TPI est disponible)"
"proportional_function": "Algorithme à utiliser (seulement TPI est disponible)",
"min_opening_degrees": "Une liste séparée par des virgules de minimum d'ouverture. Valeur par défaut : 0. Exemple : 20, 25, 30"
}
}
},
@@ -478,7 +482,8 @@
"window_open_detection_method": "Une seule méthode de détection des ouvertures ouvertes doit être utilisée. Utilisez le détecteur d'ouverture ou les seuils de température mais pas les deux.",
"no_central_config": "Vous ne pouvez pas cocher 'Utiliser la configuration centrale' car aucune configuration centrale n'a été trouvée. Vous devez créer un Versatile Thermostat de type 'Central Configuration' pour pouvoir l'utiliser.",
"service_configuration_format": "Mauvais format de la configuration du service",
"valve_regulation_nb_entities_incorrect": "Le nombre d'entités pour la régulation par vanne doit être égal au nombre d'entité sous-jacentes"
"valve_regulation_nb_entities_incorrect": "Le nombre d'entités pour la régulation par vanne doit être égal au nombre d'entité sous-jacentes",
"min_opening_degrees_format": "Une liste d'entiers positifs séparés par des ',' est attendu. Exemple : 20, 25, 30"
},
"abort": {
"already_configured": "Le device est déjà configuré"

View File

@@ -143,15 +143,15 @@
"description": "Configurazione avanzata dei parametri. Lasciare i valori predefiniti se non conoscete cosa state modificando.\nQuesti parametri possono determinare una pessima gestione della temperatura e della potenza.",
"data": {
"minimal_activation_delay": "Ritardo minimo di accensione",
"security_delay_min": "Ritardo di sicurezza (in minuti)",
"security_min_on_percent": "Percentuale minima di potenza per la modalità di sicurezza",
"security_default_on_percent": "Percentuale di potenza per la modalità di sicurezza"
"safety_delay_min": "Ritardo di sicurezza (in minuti)",
"safety_min_on_percent": "Percentuale minima di potenza per la modalità di sicurezza",
"safety_default_on_percent": "Percentuale di potenza per la modalità di sicurezza"
},
"data_description": {
"minimal_activation_delay": "Ritardo in secondi al di sotto del quale l'apparecchiatura non verrà attivata",
"security_delay_min": "Ritardo massimo consentito in minuti tra due misure di temperatura. Al di sopra di questo ritardo, il termostato passerà allo stato di sicurezza",
"security_min_on_percent": "Soglia percentuale minima di riscaldamento al di sotto della quale il preset di sicurezza non verrà mai attivato",
"security_default_on_percent": "Valore percentuale predefinito della potenza di riscaldamento nella modalità di sicurezza. Impostare a 0 per spegnere il riscaldatore nella modalità di sicurezza"
"safety_delay_min": "Ritardo massimo consentito in minuti tra due misure di temperatura. Al di sopra di questo ritardo, il termostato passerà allo stato di sicurezza",
"safety_min_on_percent": "Soglia percentuale minima di riscaldamento al di sotto della quale il preset di sicurezza non verrà mai attivato",
"safety_default_on_percent": "Valore percentuale predefinito della potenza di riscaldamento nella modalità di sicurezza. Impostare a 0 per spegnere il riscaldatore nella modalità di sicurezza"
}
}
},
@@ -307,15 +307,15 @@
"description": "Configurazione avanzata dei parametri. Lasciare i valori predefiniti se non conoscete cosa state modificando.\nQuesti parametri possono determinare una pessima gestione della temperatura e della potenza.",
"data": {
"minimal_activation_delay": "Ritardo minimo di accensione",
"security_delay_min": "Ritardo di sicurezza (in minuti)",
"security_min_on_percent": "Percentuale minima di potenza per la modalità di sicurezza",
"security_default_on_percent": "Percentuale di potenza per la modalità di sicurezza"
"safety_delay_min": "Ritardo di sicurezza (in minuti)",
"safety_min_on_percent": "Percentuale minima di potenza per la modalità di sicurezza",
"safety_default_on_percent": "Percentuale di potenza per la modalità di sicurezza"
},
"data_description": {
"minimal_activation_delay": "Ritardo in secondi al di sotto del quale l'apparecchiatura non verrà attivata",
"security_delay_min": "Ritardo massimo consentito in minuti tra due misure di temperatura. Al di sopra di questo ritardo, il termostato passerà allo stato di sicurezza",
"security_min_on_percent": "Soglia percentuale minima di riscaldamento al di sotto della quale il preset di sicurezza non verrà mai attivato",
"security_default_on_percent": "Valore percentuale predefinito della potenza di riscaldamento nella modalità di sicurezza. Impostare a 0 per spegnere il riscaldatore nella modalità di sicurezza"
"safety_delay_min": "Ritardo massimo consentito in minuti tra due misure di temperatura. Al di sopra di questo ritardo, il termostato passerà allo stato di sicurezza",
"safety_min_on_percent": "Soglia percentuale minima di riscaldamento al di sotto della quale il preset di sicurezza non verrà mai attivato",
"safety_default_on_percent": "Valore percentuale predefinito della potenza di riscaldamento nella modalità di sicurezza. Impostare a 0 per spegnere il riscaldatore nella modalità di sicurezza"
}
}
},

View File

@@ -211,16 +211,16 @@
"description": "Konfigurácia pokročilých parametrov. Ak neviete, čo robíte, ponechajte predvolené hodnoty.\nTento parameter môže viesť k veľmi zlej regulácii teploty alebo výkonu.",
"data": {
"minimal_activation_delay": "Minimálne oneskorenie aktivácie",
"security_delay_min": "Bezpečnostné oneskorenie (v minútach)",
"security_min_on_percent": "Minimálne percento výkonu na aktiváciu bezpečnostného režimu",
"security_default_on_percent": "Percento výkonu na použitie v bezpečnostnom režime",
"safety_delay_min": "Bezpečnostné oneskorenie (v minútach)",
"safety_min_on_percent": "Minimálne percento výkonu na aktiváciu bezpečnostného režimu",
"safety_default_on_percent": "Percento výkonu na použitie v bezpečnostnom režime",
"use_advanced_central_config": "Použite centrálnu rozšírenú konfiguráciu"
},
"data_description": {
"minimal_activation_delay": "Oneskorenie v sekundách, pri ktorom sa zariadenie neaktivuje",
"security_delay_min": "Maximálne povolené oneskorenie v minútach medzi dvoma meraniami teploty. Po uplynutí tohto oneskorenia sa termostat prepne do bezpečnostného vypnutého stavu",
"security_min_on_percent": "Minimálna percentuálna hodnota ohrevu pre aktiváciu prednastavenej bezpečnosti. Pod týmto percentom výkonu termostat neprejde do prednastavenia zabezpečenia",
"security_default_on_percent": "Predvolená percentuálna hodnota vykurovacieho výkonu v bezpečnostnej predvoľbe. Nastavte na 0, ak chcete vypnúť ohrievač v zabezpečenom stave",
"safety_delay_min": "Maximálne povolené oneskorenie v minútach medzi dvoma meraniami teploty. Po uplynutí tohto oneskorenia sa termostat prepne do bezpečnostného vypnutého stavu",
"safety_min_on_percent": "Minimálna percentuálna hodnota ohrevu pre aktiváciu prednastavenej bezpečnosti. Pod týmto percentom výkonu termostat neprejde do prednastavenia zabezpečenia",
"safety_default_on_percent": "Predvolená percentuálna hodnota vykurovacieho výkonu v bezpečnostnej predvoľbe. Nastavte na 0, ak chcete vypnúť ohrievač v zabezpečenom stave",
"use_advanced_central_config": "Začiarknite, ak chcete použiť centrálnu rozšírenú konfiguráciu. Zrušte začiarknutie, ak chcete použiť špecifickú rozšírenú konfiguráciu pre tento VTherm"
}
}
@@ -446,16 +446,16 @@
"description": "Konfigurácia pokročilých parametrov. Ak neviete, čo robíte, ponechajte predvolené hodnoty.\nTento parameter môže viesť k veľmi zlej regulácii teploty alebo výkonu.",
"data": {
"minimal_activation_delay": "Minimálne oneskorenie aktivácie",
"security_delay_min": "Bezpečnostné oneskorenie (v minútach)",
"security_min_on_percent": "Minimálne percento výkonu pre bezpečnostný režim",
"security_default_on_percent": "Percento výkonu na použitie v bezpečnostnom režime",
"safety_delay_min": "Bezpečnostné oneskorenie (v minútach)",
"safety_min_on_percent": "Minimálne percento výkonu pre bezpečnostný režim",
"safety_default_on_percent": "Percento výkonu na použitie v bezpečnostnom režime",
"use_advanced_central_config": "Použite centrálnu rozšírenú konfiguráciu"
},
"data_description": {
"minimal_activation_delay": "Oneskorenie v sekundách, pri ktorom sa zariadenie neaktivuje",
"security_delay_min": "Maximálne povolené oneskorenie v minútach medzi dvoma meraniami teploty. Po uplynutí tohto oneskorenia sa termostat prepne do bezpečnostného vypnutého stavu",
"security_min_on_percent": "Minimálna percentuálna hodnota ohrevu pre aktiváciu prednastavenej bezpečnosti. Pod týmto percentom výkonu termostat neprejde do prednastavenia zabezpečenia",
"security_default_on_percent": "Predvolená percentuálna hodnota vykurovacieho výkonu v bezpečnostnej predvoľbe. Nastavte na 0, ak chcete vypnúť ohrievač v zabezpečenom stave",
"safety_delay_min": "Maximálne povolené oneskorenie v minútach medzi dvoma meraniami teploty. Po uplynutí tohto oneskorenia sa termostat prepne do bezpečnostného vypnutého stavu",
"safety_min_on_percent": "Minimálna percentuálna hodnota ohrevu pre aktiváciu prednastavenej bezpečnosti. Pod týmto percentom výkonu termostat neprejde do prednastavenia zabezpečenia",
"safety_default_on_percent": "Predvolená percentuálna hodnota vykurovacieho výkonu v bezpečnostnej predvoľbe. Nastavte na 0, ak chcete vypnúť ohrievač v zabezpečenom stave",
"use_advanced_central_config": "Začiarknite, ak chcete použiť centrálnu rozšírenú konfiguráciu. Zrušte začiarknutie, ak chcete použiť špecifickú rozšírenú konfiguráciu pre tento VTherm"
}
}
@@ -578,4 +578,4 @@
}
}
}
}
}

View File

@@ -252,7 +252,7 @@ class UnderlyingSwitch(UnderlyingEntity):
self._cancel_cycle()
if self.hvac_mode != hvac_mode:
super().set_hvac_mode(hvac_mode)
await super().set_hvac_mode(hvac_mode)
return True
else:
return False
@@ -409,11 +409,11 @@ class UnderlyingSwitch(UnderlyingEntity):
await self.turn_off()
return
if await self._thermostat.check_overpowering():
if await self._thermostat.power_manager.check_overpowering():
_LOGGER.debug("%s - End of cycle (3)", self)
return
# safety mode could have change the on_time percent
await self._thermostat.check_safety()
await self._thermostat.safety_manager.refresh_state()
time = self._on_time_sec
action_label = "start"
@@ -1029,6 +1029,7 @@ class UnderlyingValveRegulation(UnderlyingValve):
opening_degree_entity_id: str,
closing_degree_entity_id: str,
climate_underlying: UnderlyingClimate,
min_opening_degree: int = 0,
) -> None:
"""Initialize the underlying TRV with valve regulation"""
super().__init__(
@@ -1045,6 +1046,7 @@ class UnderlyingValveRegulation(UnderlyingValve):
self._max_opening_degree: float = None
self._min_offset_calibration: float = None
self._max_offset_calibration: float = None
self._min_opening_degree: int = min_opening_degree
async def send_percent_open(self):
"""Send the percent open to the underlying valve"""
@@ -1079,6 +1081,9 @@ class UnderlyingValveRegulation(UnderlyingValve):
return
# Send opening_degree
if 0 < self._percent_open < self._min_opening_degree:
self._percent_open = self._min_opening_degree
await super().send_percent_open()
# Send closing_degree if set
@@ -1138,6 +1143,11 @@ class UnderlyingValveRegulation(UnderlyingValve):
"""The offset_calibration_entity_id"""
return self._closing_degree_entity_id
@property
def min_opening_degree(self) -> int:
"""The minimum opening degree"""
return self._min_opening_degree
@property
def have_closing_degree_entity(self) -> bool:
"""Return True if the underlying have a closing_degree entity"""

View File

@@ -125,15 +125,10 @@ class VersatileThermostatAPI(dict):
):
"""register the two number entities needed for boiler activation"""
self._threshold_number_entity = threshold_number_entity
# If sensor and threshold number are initialized, reload the listener
# if self._nb_active_number_entity and self._central_boiler_entity:
# self._hass.async_add_job(self.reload_central_boiler_binary_listener)
def register_nb_device_active_boiler(self, nb_active_number_entity):
"""register the two number entities needed for boiler activation"""
self._nb_active_number_entity = nb_active_number_entity
# if self._threshold_number_entity and self._central_boiler_entity:
# self._hass.async_add_job(self.reload_central_boiler_binary_listener)
def register_temperature_number(
self,
@@ -172,13 +167,6 @@ class VersatileThermostatAPI(dict):
)
if component:
for entity in component.entities:
# if hasattr(entity, "init_presets"):
# if (
# only_use_central is False
# or entity.use_central_config_temperature
# ):
# await entity.init_presets(self.find_central_configuration())
# A little hack to test if the climate is a VTherm. Cannot use isinstance
# due to circular dependency of BaseThermostat
if (

View File

@@ -27,12 +27,12 @@ The first delay (`minimal_activation_delay_sec`) in seconds is the minimum accep
### Safety Mode
The second delay (`security_delay_min`) is the maximum time between two temperature measurements before the _VTherm_ switches to Safety Mode.
The second delay (`safety_delay_min`) is the maximum time between two temperature measurements before the _VTherm_ switches to Safety Mode.
The third parameter (`security_min_on_percent`) is the minimum `on_percent` below which Safety Mode will not be activated. This setting prevents activating Safety Mode if the controlled radiator does not heat sufficiently. In this case, there is no physical risk to the home, only the risk of overheating or underheating.
The third parameter (`safety_min_on_percent`) is the minimum `on_percent` below which Safety Mode will not be activated. This setting prevents activating Safety Mode if the controlled radiator does not heat sufficiently. In this case, there is no physical risk to the home, only the risk of overheating or underheating.
Setting this parameter to `0.00` will trigger Safety Mode regardless of the last heating setting, whereas `1.00` will never trigger Safety Mode (effectively disabling the feature). This can be useful to adapt the safety mechanism to your specific needs.
The fourth parameter (`security_default_on_percent`) defines the `on_percent` used when the thermostat switches to `security` mode. Setting it to `0` will turn off the thermostat in Safety Mode, while setting it to a value like `0.2` (20%) ensures some heating remains, avoiding a completely frozen home in case of a thermometer failure.
The fourth parameter (`safety_default_on_percent`) defines the `on_percent` used when the thermostat switches to `security` mode. Setting it to `0` will turn off the thermostat in Safety Mode, while setting it to a value like `0.2` (20%) ensures some heating remains, avoiding a completely frozen home in case of a thermometer failure.
It is possible to disable Safety Mode triggered by missing data from the outdoor thermometer. Since the outdoor thermometer usually has a minor impact on regulation (depending on your configuration), it might not be critical if it's unavailable. To do this, add the following lines to your `configuration.yaml`:
@@ -49,5 +49,5 @@ By default, the outdoor thermometer can trigger Safety Mode if it stops sending
> 1. When the temperature sensor resumes reporting, the preset will be restored to its previous value.
> 2. Two temperature sources are required: the indoor and outdoor temperatures. Both must report values, or the thermostat will switch to "security" preset.
> 3. An action is available to adjust the three safety parameters. This can help adapt Safety Mode to your needs.
> 4. For normal use, `security_default_on_percent` should be lower than `security_min_on_percent`.
> 4. For normal use, `safety_default_on_percent` should be lower than `safety_min_on_percent`.
> 5. If you use the Versatile Thermostat UI card (see [here](additions.md#better-with-the-versatile-thermostat-ui-card)), a _VTherm_ in Safety Mode is indicated by a gray overlay showing the faulty thermometer and the time since its last value update: ![safety mode](images/safety-mode-icon.png).

Binary file not shown.

After

Width:  |  Height:  |  Size: 67 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 67 KiB

After

Width:  |  Height:  |  Size: 62 KiB

View File

@@ -678,14 +678,14 @@ Le formulaire de configuration avancée est le suivant :
Le premier délai (minimal_activation_delay_sec) en secondes est le délai minimum acceptable pour allumer le chauffage. Lorsque le calcul donne un délai de mise sous tension inférieur à cette valeur, le chauffage reste éteint.
Le deuxième délai (``security_delay_min``) est le délai maximal entre deux mesures de température avant de régler le préréglage sur ``security``. Si le capteur de température ne donne plus de mesures de température, le thermostat et le radiateur passeront en mode ``security`` après ce délai. Ceci est utile pour éviter une surchauffe si la batterie de votre capteur de température est trop faible.
Le deuxième délai (``safety_delay_min``) est le délai maximal entre deux mesures de température avant de régler le préréglage sur ``security``. Si le capteur de température ne donne plus de mesures de température, le thermostat et le radiateur passeront en mode ``security`` après ce délai. Ceci est utile pour éviter une surchauffe si la batterie de votre capteur de température est trop faible.
Le troisième paramétre (``security_min_on_percent``) est la valeur minimal de ``on_percent`` en dessous de laquelle le préréglage sécurité ne sera pas activé. Ce paramètre permet de ne pas mettre en sécurité un thermostat, si le radiateur piloté ne chauffe pas suffisament.
Le troisième paramétre (``safety_min_on_percent``) est la valeur minimal de ``on_percent`` en dessous de laquelle le préréglage sécurité ne sera pas activé. Ce paramètre permet de ne pas mettre en sécurité un thermostat, si le radiateur piloté ne chauffe pas suffisament.
Mettre ce paramètre à ``0.00`` déclenchera le préréglage sécurité quelque soit la dernière consigne de chauffage, à l'inverse ``1.00`` ne déclenchera jamais le préréglage sécurité ( ce qui revient à désactiver la fonction).
Le quatrième param§tre (``security_default_on_percent``) est la valeur de ``on_percent`` qui sera utilisée lorsque le thermostat passe en mode ``security``. Si vous mettez ``0`` alors le thermostat sera coupé lorsqu'il passe en mode ``security``, mettre 0,2% par exemple permet de garder un peu de chauffage (20% dans ce cas), même en mode ``security``. Ca évite de retrouver son logement totalement gelé lors d'une panne de thermomètre.
Le quatrième param§tre (``safety_default_on_percent``) est la valeur de ``on_percent`` qui sera utilisée lorsque le thermostat passe en mode ``security``. Si vous mettez ``0`` alors le thermostat sera coupé lorsqu'il passe en mode ``security``, mettre 0,2% par exemple permet de garder un peu de chauffage (20% dans ce cas), même en mode ``security``. Ca évite de retrouver son logement totalement gelé lors d'une panne de thermomètre.
Note: les paramètres `security_min_on_percent` et `security_default_on_percent` ne s'applique pas aux VTherms `over_climate`.
Note: les paramètres `safety_min_on_percent` et `safety_default_on_percent` ne s'applique pas aux VTherms `over_climate`.
Depuis la version 5.3 il est possible de désactiver la mise en sécurité suite à une absence de données du thermomètre extérieure. En effet, celui-ci ayant la plupart du temps un impact faible sur la régulation (dépendant de votre paramètrage), il est possible qu'il soit absent sans mettre en danger le logement. Pour cela, il faut ajouter les lignes suivantes dans votre `configuration.yaml` :
```
@@ -702,7 +702,7 @@ Voir [exemple de réglages](#examples-tuning) pour avoir des exemples de réglag
> 1. Lorsque le capteur de température viendra à la vie et renverra les températures, le préréglage sera restauré à sa valeur précédente,
> 2. Attention, deux températures sont nécessaires : la température interne et la température externe et chacune doit donner la température, sinon le thermostat sera en préréglage "security",
> 3. Un service est disponible qui permet de régler les 3 paramètres de sécurité. Ca peut servir à adapter la fonction de sécurité à votre usage,
> 4. Pour un usage naturel, le ``security_default_on_percent`` doit être inférieur à ``security_min_on_percent``,
> 4. Pour un usage naturel, le ``safety_default_on_percent`` doit être inférieur à ``safety_min_on_percent``,
> 5. Les thermostats de type ``thermostat_over_climate`` ne sont pas concernés par le mode security.
## Le contrôle centralisé
@@ -875,8 +875,8 @@ context:
| ``power_temp`` | Température si délestaqe | X | X | X | X |
| ``presence_sensor_entity_id`` | Capteur de présence entity id (true si quelqu'un est présent) | X | X | X | - |
| ``minimal_activation_delay`` | Délai minimal d'activation | X | - | - | X |
| ``security_delay_min`` | Délai maximal entre 2 mesures de températures | X | - | X | X |
| ``security_min_on_percent`` | Pourcentage minimal de puissance pour passer en mode sécurité | X | - | X | X |
| ``safety_delay_min`` | Délai maximal entre 2 mesures de températures | X | - | X | X |
| ``safety_min_on_percent`` | Pourcentage minimal de puissance pour passer en mode sécurité | X | - | X | X |
| ``auto_regulation_mode`` | Le mode d'auto-régulation | - | X | - | - |
| ``auto_regulation_dtemp`` | La seuil d'auto-régulation | - | X | - | - |
| ``auto_regulation_period_min`` | La période minimale d'auto-régulation | - | X | - | - |
@@ -902,9 +902,9 @@ context:
- minimal_activation_delay_sec : 300 secondes (à cause du temps de réponse)
## Le capteur de température alimenté par batterie
- security_delay_min : 60 min (parce que ces capteurs sont paresseux)
- security_min_on_percent : 0,5 (50% - on passe en preset ``security`` si le radiateur chauffait plus de 50% du temps)
- security_default_on_percent : 0,1 (10% - en preset ``security``, on garde un fond de chauffe de 20% du temps)
- safety_delay_min : 60 min (parce que ces capteurs sont paresseux)
- safety_min_on_percent : 0,5 (50% - on passe en preset ``security`` si le radiateur chauffait plus de 50% du temps)
- safety_default_on_percent : 0,1 (10% - en preset ``security``, on garde un fond de chauffe de 20% du temps)
Il faut comprendre ces réglages comme suit :
@@ -917,9 +917,9 @@ Ce qui est important c'est de ne pas prendre trop de risque avec ces paramètres
Versatile Thermostat vous permet d'être notifié lorsqu'un évènement de ce type survient. Mettez en place, les alertes qui vont bien dès l'utilisation de ce thermostat. Cf. (#notifications)
## Capteur de température réactif (sur secteur)
- security_delay_min : 15 min
- security_min_on_percent : 0,7 (70% - on passe en preset ``security`` si le radiateur chauffait plus de 70% du temps)
- security_default_on_percent : 0,25 (25% - en preset ``security``, on garde un fond de chauffe de 25% du temps)
- safety_delay_min : 15 min
- safety_min_on_percent : 0,7 (70% - on passe en preset ``security`` si le radiateur chauffait plus de 70% du temps)
- safety_default_on_percent : 0,25 (25% - en preset ``security``, on garde un fond de chauffe de 25% du temps)
## Mes presets
Ceci est juste un exemple de la façon dont j'utilise le préréglage. A vous de vous adapter à votre configuration mais cela peut être utile pour comprendre son fonctionnement.
@@ -1053,7 +1053,7 @@ Si le thermostat est en mode ``security`` les nouveaux paramètres sont appliqu
Pour changer les paramètres de sécurité utilisez le code suivant :
```
service : versatile_thermostat.set_security
service : versatile_thermostat.set_safety
data:
min_on_percent: "0.5"
default_on_percent: "0.1"
@@ -1082,7 +1082,7 @@ Les évènements notifiés sont les suivants:
- ``versatile_thermostat_security_event`` : un thermostat entre ou sort du preset ``security``
- ``versatile_thermostat_power_event`` : un thermostat entre ou sort du preset ``power``
- ``versatile_thermostat_temperature_event`` : une ou les deux mesures de température d'un thermostat n'ont pas été mis à jour depuis plus de `security_delay_min`` minutes
- ``versatile_thermostat_temperature_event`` : une ou les deux mesures de température d'un thermostat n'ont pas été mis à jour depuis plus de `safety_delay_min`` minutes
- ``versatile_thermostat_hvac_mode_event`` : le thermostat est allumé ou éteint. Cet évènement est aussi diffusé au démarrage du thermostat
- ``versatile_thermostat_preset_event`` : un nouveau preset est sélectionné sur le thermostat. Cet évènement est aussi diffusé au démarrage du thermostat
- ``versatile_thermostat_central_boiler_event`` : un évènement indiquant un changement dans l'état de la chaudière.
@@ -1126,13 +1126,13 @@ Les attributs personnalisés sont les suivants :
| ``saved_preset_mode`` | Le dernier preset utilisé avant le basculement automatique du preset |
| ``saved_target_temp`` | La dernière température utilisée avant la commutation automatique |
| ``window_state`` | Le dernier état connu du capteur de fenêtre. Aucun si la fenêtre n'est pas configurée |
| ``window_bypass_state`` | True si le bypass de la détection d'ouverture et activé |
| ``is_window_bypass`` | True si le bypass de la détection d'ouverture et activé |
| ``motion_state`` | Le dernier état connu du capteur de mouvement. Aucun si le mouvement n'est pas configuré |
| ``overpowering_state`` | Le dernier état connu du capteur surpuissant. Aucun si la gestion de l'alimentation n'est pas configurée |
| ``presence_state`` | Le dernier état connu du capteur de présence. Aucun si la gestion de présence n'est pas configurée |
| ``security_delay_min`` | Le délai avant d'activer le mode de sécurité lorsque un des 2 capteurs de température n'envoie plus de mesures |
| ``security_min_on_percent`` | Pourcentage de chauffe en dessous duquel le thermostat ne passera pas en sécurité |
| ``security_default_on_percent`` | Pourcentage de chauffe utilisé lorsque le thermostat est en sécurité |
| ``safety_delay_min`` | Le délai avant d'activer le mode de sécurité lorsque un des 2 capteurs de température n'envoie plus de mesures |
| ``safety_min_on_percent`` | Pourcentage de chauffe en dessous duquel le thermostat ne passera pas en sécurité |
| ``safety_default_on_percent`` | Pourcentage de chauffe utilisé lorsque le thermostat est en sécurité |
| ``last_temperature_datetime`` | La date et l'heure au format ISO8866 de la dernière réception de température interne |
| ``last_ext_temperature_datetime`` | La date et l'heure au format ISO8866 de la dernière réception de température extérieure |
| ``security_state`` | L'état de sécurité. vrai ou faux |
@@ -1571,9 +1571,9 @@ Ces paramètres sont sensibles et assez difficiles à régler. Merci de ne les u
<summary>Pourquoi mon Versatile Thermostat se met en Securite ?</summary>
## Pourquoi mon Versatile Thermostat se met en Securite ?
Le mode sécurité est possible sur tous les types de VTherm . Il survient lorsqu'un des 2 thermomètres qui donne la température de la pièce ou la température extérieure n'a pas envoyé de valeur depuis plus de `security_delay_min` minutes et que le radiateur chauffait à au moins `security_min_on_percent`.
Le mode sécurité est possible sur tous les types de VTherm . Il survient lorsqu'un des 2 thermomètres qui donne la température de la pièce ou la température extérieure n'a pas envoyé de valeur depuis plus de `safety_delay_min` minutes et que le radiateur chauffait à au moins `safety_min_on_percent`.
Comme l'algorithme est basé sur les mesures de température, si elles ne sont plus reçues par le VTherm, il y a un risque de surchauffe et d'incendie. Pour éviter ça, lorsque les conditions rappelées ci-dessus sont détectées, la chauffe est limité au paramètre `security_default_on_percent`. Cette valeur doit donc être raisonnablement faible (10% est une bonne valeur). Elle permet d'éviter un incendie tout en évitant de couper totalement le radiateur (risque de gel).
Comme l'algorithme est basé sur les mesures de température, si elles ne sont plus reçues par le VTherm, il y a un risque de surchauffe et d'incendie. Pour éviter ça, lorsque les conditions rappelées ci-dessus sont détectées, la chauffe est limité au paramètre `safety_default_on_percent`. Cette valeur doit donc être raisonnablement faible (10% est une bonne valeur). Elle permet d'éviter un incendie tout en évitant de couper totalement le radiateur (risque de gel).
Tous ces paramètres se règlent dans la dernière page de la configuration du VTherm : "Paramètres avancés".
@@ -1596,14 +1596,14 @@ last_temperature_datetime: "2023-12-06T18:43:28.346010+01:00"
last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00"
last_update_datetime: "2023-12-06T18:43:28.351103+01:00"
...
security_delay_min: 60
safety_delay_min: 60
```
On voit que :
1. le VTherm est bien en mode sécurité (`security_state: true`),
2. l'heure courante est le 06/12/2023 à 18h43:28 (`last_update_datetime: "2023-12-06T18:43:28.351103+01:00"`),
3. l'heure de dernière réception de la température intérieure est le 06/12/2023 à 18h43:28 (`last_temperature_datetime: "2023-12-06T18:43:28.346010+01:00"`). Elle est donc récente,
4. l'heure de dernière réception de la température extérieure est le 06/12/2023 à 13h04:35 (`last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00`). C'est donc l'heure extérieure qui a plus de 5 h de retard et qui a provoquée le passage en mode sécurité, car le seuil est limité à 60 min (`security_delay_min: 60`).
4. l'heure de dernière réception de la température extérieure est le 06/12/2023 à 13h04:35 (`last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00`). C'est donc l'heure extérieure qui a plus de 5 h de retard et qui a provoquée le passage en mode sécurité, car le seuil est limité à 60 min (`safety_delay_min: 60`).
### Comment être averti lorsque cela se produit ?
Pour être averti, le VTherm envoie un évènement dès que ça se produit et un en fin d'alerte sécurité. Vous pouvez capter ces évènements dans une automatisation et envoyer une notification par exemple, faire clignoter un voyant, déclencher une sirène, ... A vous de voir.
@@ -1613,8 +1613,8 @@ Pour manipuler les évènements générés par le VTherm, cf. [Eveènements](#ev
### Comment réparer ?
Cela va dépendre de la cause du problème :
1. Si un capteur est en défaut, il faut le réparer (remettre des piles, le changer, vérifier l'intégration Météo qui donne la température extérieure, ...),
2. Si le paramètre `security_delay_min` est trop petit, cela rsique de générer beaucoup de fausses alertes. Une valeur correcte est de l'ordre de 60 min, surtout si vous avez des capteurs de température à pile.
3. Certains capteurs de température, n'envoie pas de mesure si la température n'a pas changée. Donc en cas de température très stable pendant longtemps, le mode sécurité peut se déclencher. Ce n'est pas très grave puisqu'il s'enlève dès que le VTherm reçoit à nouveau une température. Sur certain thermomètre (TuYA par exemple), on peut forcer le délai max entre 2 mesures. Il conviendra de mettre un délai max < `security_delay_min`,
2. Si le paramètre `safety_delay_min` est trop petit, cela rsique de générer beaucoup de fausses alertes. Une valeur correcte est de l'ordre de 60 min, surtout si vous avez des capteurs de température à pile.
3. Certains capteurs de température, n'envoie pas de mesure si la température n'a pas changée. Donc en cas de température très stable pendant longtemps, le mode sécurité peut se déclencher. Ce n'est pas très grave puisqu'il s'enlève dès que le VTherm reçoit à nouveau une température. Sur certain thermomètre (TuYA par exemple), on peut forcer le délai max entre 2 mesures. Il conviendra de mettre un délai max < `safety_delay_min`,
4. Dès que la température sera a nouveau reçue le mode sécurité s'enlèvera et les valeurs précédentes de preset, température cible et mode seront restaurées.
</details>

View File

@@ -61,8 +61,8 @@
| ``power_temp`` | Temperature during load shedding | X | X | X | X |
| ``presence_sensor_entity_id`` | Presence sensor entity id (true if someone is present) | X | X | X | - |
| ``minimal_activation_delay`` | Minimum activation delay | X | - | - | X |
| ``security_delay_min`` | Maximum delay between two temperature measurements | X | - | X | X |
| ``security_min_on_percent`` | Minimum power percentage to enter security mode | X | - | X | X |
| ``safety_delay_min`` | Maximum delay between two temperature measurements | X | - | X | X |
| ``safety_min_on_percent`` | Minimum power percentage to enter security mode | X | - | X | X |
| ``auto_regulation_mode`` | Auto-regulation mode | - | X | - | - |
| ``auto_regulation_dtemp`` | Auto-regulation threshold | - | X | - | - |
| ``auto_regulation_period_min`` | Minimum auto-regulation period | - | X | - | - |
@@ -175,7 +175,7 @@ If the thermostat is in ``security`` mode, the new settings are applied immediat
To change the security settings, use the following code:
```yaml
service: versatile_thermostat.set_security
service: versatile_thermostat.set_safety
data:
min_on_percent: "0.5"
default_on_percent: "0.1"
@@ -204,7 +204,7 @@ The following events are notified:
- ``versatile_thermostat_security_event``: the thermostat enters or exits the ``security`` preset
- ``versatile_thermostat_power_event``: the thermostat enters or exits the ``power`` preset
- ``versatile_thermostat_temperature_event``: one or both temperature measurements of the thermostat haven't been updated for more than `security_delay_min`` minutes
- ``versatile_thermostat_temperature_event``: one or both temperature measurements of the thermostat haven't been updated for more than `safety_delay_min`` minutes
- ``versatile_thermostat_hvac_mode_event``: the thermostat is turned on or off. This event is also broadcast at the thermostat's startup
- ``versatile_thermostat_preset_event``: a new preset is selected on the thermostat. This event is also broadcast at the thermostat's startup
- ``versatile_thermostat_central_boiler_event``: an event indicating a change in the boiler's state
@@ -248,13 +248,13 @@ The custom attributes are as follows:
| ``saved_preset_mode`` | The last preset used before automatic preset switching |
| ``saved_target_temp`` | The last temperature used before automatic switching |
| ``window_state`` | The last known state of the window sensor. None if the window is not configured |
| ``window_bypass_state`` | True if the window open detection bypass is enabled |
| ``is_window_bypass`` | True if the window open detection bypass is enabled |
| ``motion_state`` | The last known state of the motion sensor. None if motion detection is not configured |
| ``overpowering_state`` | The last known state of the overpower sensor. None if power management is not configured |
| ``presence_state`` | The last known state of the presence sensor. None if presence detection is not configured |
| ``security_delay_min`` | The delay before activating security mode when one of the two temperature sensors stops sending measurements |
| ``security_min_on_percent`` | The heating percentage below which the thermostat will not switch to security |
| ``security_default_on_percent`` | The heating percentage used when the thermostat is in security mode |
| ``safety_delay_min`` | The delay before activating security mode when one of the two temperature sensors stops sending measurements |
| ``safety_min_on_percent`` | The heating percentage below which the thermostat will not switch to security |
| ``safety_default_on_percent`` | The heating percentage used when the thermostat is in security mode |
| ``last_temperature_datetime`` | The date and time in ISO8866 format of the last internal temperature reception |
| ``last_ext_temperature_datetime`` | The date and time in ISO8866 format of the last external temperature reception |
| ``security_state`` | The security state. True or false |
@@ -271,5 +271,9 @@ The custom attributes are as follows:
| ``auto_start_stop_enable`` | Indicates if the VTherm is allowed to auto start/stop |
| ``auto_start_stop_level`` | Indicates the auto start/stop level |
| ``hvac_off_reason`` | Indicates the reason for the thermostat's off state (hvac_off). It can be Window, Auto-start/stop, or Manual |
| ``last_change_time_from_vtherm`` | The date and time of the last change done by VTherm |
| ``nb_device_actives`` | The number of underlying devices seen as active |
| ``device_actives`` | The list of underlying devices seen as active |
These attributes will be requested when you need assistance.

View File

@@ -32,6 +32,7 @@ You need to provide:
1. As many valve opening control entities as there are underlying devices, and in the same order. These parameters are mandatory.
2. As many temperature calibration entities as there are underlying devices, and in the same order. These parameters are optional; they must either all be provided or none.
3. As many valve closure control entities as there are underlying devices, and in the same order. These parameters are optional; they must either all be provided or none.
4. A list of minimum opening values for the valve when it needs to be opened. This field is a list of integers. If the valve needs to be opened, it will be opened at a minimum of this opening value. This allows enough water to pass through when it needs to be opened.
The opening rate calculation algorithm is based on the _TPI_ algorithm described [here](algorithms.md). This is the same algorithm used for _VTherms_ `over_switch` and `over_valve`.

View File

@@ -15,6 +15,7 @@
- [How to Fix It?](#how-to-fix-it)
- [Using a Group of People as a Presence Sensor](#using-a-group-of-people-as-a-presence-sensor)
- [Enable Logs for the Versatile Thermostat](#enable-logs-for-the-versatile-thermostat)
- [VTherm does not track setpoint changes made directly on the underlying device (`over_climate`)](#vtherm-does-not-track-setpoint-changes-made-directly-on-the-underlying-device-over_climate)
## Using a Heatzy
@@ -124,9 +125,9 @@ These parameters are sensitive and quite difficult to adjust. Please only use th
## Why is my Versatile Thermostat going into Safety Mode?
Safety mode is only available for VTherm types `over_switch` and `over_valve`. It occurs when one of the two thermometers (providing either the room temperature or the external temperature) has not sent a value for more than `security_delay_min` minutes, and the radiator had been heating at least `security_min_on_percent`. See [safety mode](feature-advanced.md#safety-mode)
Safety mode is only available for VTherm types `over_switch` and `over_valve`. It occurs when one of the two thermometers (providing either the room temperature or the external temperature) has not sent a value for more than `safety_delay_min` minutes, and the radiator had been heating at least `safety_min_on_percent`. See [safety mode](feature-advanced.md#safety-mode)
Since the algorithm relies on temperature measurements, if they are no longer received by the VTherm, there is a risk of overheating and fire. To prevent this, when the above conditions are detected, heating is limited to the `security_default_on_percent` parameter. This value should therefore be reasonably low (10% is a good value). It helps avoid a fire while preventing the radiator from being completely turned off (risk of freezing).
Since the algorithm relies on temperature measurements, if they are no longer received by the VTherm, there is a risk of overheating and fire. To prevent this, when the above conditions are detected, heating is limited to the `safety_default_on_percent` parameter. This value should therefore be reasonably low (10% is a good value). It helps avoid a fire while preventing the radiator from being completely turned off (risk of freezing).
All these parameters are configured on the last page of the VTherm configuration: "Advanced Settings".
@@ -150,14 +151,14 @@ last_temperature_datetime: "2023-12-06T18:43:28.346010+01:00"
last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00"
last_update_datetime: "2023-12-06T18:43:28.351103+01:00"
...
security_delay_min: 60
safety_delay_min: 60
```
We can see that:
1. The VTherm is indeed in safety mode (`security_state: true`),
2. The current time is 06/12/2023 at 18:43:28 (`last_update_datetime: "2023-12-06T18:43:28.351103+01:00"`),
3. The last reception time of the room temperature is 06/12/2023 at 18:43:28 (`last_temperature_datetime: "2023-12-06T18:43:28.346010+01:00"`), so it's recent,
4. The last reception time of the external temperature is 06/12/2023 at 13:04:35 (`last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00"`). The external temperature is over 5 hours late, which triggered the safety mode, as the threshold is set to 60 minutes (`security_delay_min: 60`).
4. The last reception time of the external temperature is 06/12/2023 at 13:04:35 (`last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00"`). The external temperature is over 5 hours late, which triggered the safety mode, as the threshold is set to 60 minutes (`safety_delay_min: 60`).
### How to Be Notified When This Happens?
The VTherm sends an event as soon as this happens and again at the end of the safety alert. You can capture these events in an automation and send a notification, blink a light, trigger a siren, etc. It's up to you.
@@ -167,8 +168,8 @@ For handling events generated by VTherm, see [Events](#events).
### How to Fix It?
It depends on the cause of the problem:
1. If a sensor is faulty, it should be repaired (replace batteries, change it, check the weather integration that provides the external temperature, etc.),
2. If the `security_delay_min` parameter is too small, it may generate many false alerts. A correct value is around 60 minutes, especially if you have battery-powered temperature sensors. See [my settings](tuning-examples.md#battery-powered-temperature-sensor),
3. Some temperature sensors don't send measurements if the temperature hasn't changed. So if the temperature stays very stable for a long time, safety mode can trigger. This is not a big issue since it will deactivate once the VTherm receives a new temperature. On some thermometers (e.g., TuYA or Zigbee), you can force a max delay between two measurements. The max delay should be set to a value lower than `security_delay_min`,
2. If the `safety_delay_min` parameter is too small, it may generate many false alerts. A correct value is around 60 minutes, especially if you have battery-powered temperature sensors. See [my settings](tuning-examples.md#battery-powered-temperature-sensor),
3. Some temperature sensors don't send measurements if the temperature hasn't changed. So if the temperature stays very stable for a long time, safety mode can trigger. This is not a big issue since it will deactivate once the VTherm receives a new temperature. On some thermometers (e.g., TuYA or Zigbee), you can force a max delay between two measurements. The max delay should be set to a value lower than `safety_delay_min`,
4. As soon as the temperature is received again, safety mode will turn off, and the previous preset, target temperature, and mode values will be restored.
5. If the external temperature sensor is faulty, you can disable safety mode triggering as it has a minimal impact on the results. To do so, see [here](feature-advanced.md#safety-mode).
@@ -208,4 +209,8 @@ logs:
```
You must reload the YAML configuration (Developer Tools / YAML / Reload all YAML configuration) or restart Home Assistant for this change to take effect.
Be careful, in debug mode, Versatile Thermostat is very verbose and can quickly slow down Home Assistant or saturate your hard drive. If you switch to debug mode for anomaly analysis, do so only for the time needed to reproduce the bug and disable debug mode immediately afterward.
Be careful, in debug mode, Versatile Thermostat is very verbose and can quickly slow down Home Assistant or saturate your hard drive. If you switch to debug mode for anomaly analysis, do so only for the time needed to reproduce the bug and disable debug mode immediately afterward.
## VTherm does not track setpoint changes made directly on the underlying device (`over_climate`)
See the details of this feature [here](over-climate.md#track-underlying-temperature-changes).

View File

@@ -18,9 +18,9 @@
## Battery-Powered Temperature Sensor
These sensors are often sluggish and do not always send temperature readings when the temperature is stable. Therefore, the settings should be loose to avoid false positives.
- security_delay_min: 60 minutes (because these sensors are sluggish)
- security_min_on_percent: 0.7 (70% - the system goes into security mode if the heater was on more than 70% of the time)
- security_default_on_percent: 0.4 (40% - in security mode, we maintain 40% heating time to avoid getting too cold)
- safety_delay_min: 60 minutes (because these sensors are sluggish)
- safety_min_on_percent: 0.7 (70% - the system goes into security mode if the heater was on more than 70% of the time)
- safety_default_on_percent: 0.4 (40% - in security mode, we maintain 40% heating time to avoid getting too cold)
These settings should be understood as follows:
@@ -35,9 +35,9 @@ Versatile Thermostat allows you to be notified when such an event occurs. Set up
## Reactive Temperature Sensor (plugged in)
A powered thermometer is supposed to be very regular in sending temperature readings. If it doesn't send anything for 15 minutes, it most likely has an issue, and we can react faster without the risk of a false positive.
- security_delay_min: 15 minutes
- security_min_on_percent: 0.5 (50% - the system goes into ``security`` preset if the heater was on more than 50% of the time)
- security_default_on_percent: 0.25 (25% - in ``security`` preset, we keep 25% heating time)
- safety_delay_min: 15 minutes
- safety_min_on_percent: 0.5 (50% - the system goes into ``security`` preset if the heater was on more than 50% of the time)
- safety_default_on_percent: 0.25 (25% - in ``security`` preset, we keep 25% heating time)
## My Presets
This is just an example of how I use the preset. You can adapt it to your configuration, but it may be useful to understand its functionality.

View File

@@ -27,12 +27,12 @@ Le premier délai (`minimal_activation_delay_sec`) en secondes est le délai min
### La mise en sécurité
Le deuxième délai (`security_delay_min`) est le délai maximal entre deux mesures de température avant de passer le _VTherm_ en mode sécurité.
Le deuxième délai (`safety_delay_min`) est le délai maximal entre deux mesures de température avant de passer le _VTherm_ en mode sécurité.
Le troisième paramètre (`security_min_on_percent`) est la valeur minimal de `on_percent` en dessous de laquelle le préréglage sécurité ne sera pas activé. Ce paramètre permet de ne pas mettre en sécurité un thermostat, si le radiateur piloté ne chauffe pas suffisament. En effet, il n'y a pas de risque physique pour le logement dans ce cas mais juste un risque de surchauffe ou de sous-chauffe.
Le troisième paramètre (`safety_min_on_percent`) est la valeur minimal de `on_percent` en dessous de laquelle le préréglage sécurité ne sera pas activé. Ce paramètre permet de ne pas mettre en sécurité un thermostat, si le radiateur piloté ne chauffe pas suffisament. En effet, il n'y a pas de risque physique pour le logement dans ce cas mais juste un risque de surchauffe ou de sous-chauffe.
Mettre ce paramètre à ``0.00`` déclenchera le préréglage sécurité quelque soit la dernière consigne de chauffage, à l'inverse ``1.00`` ne déclenchera jamais le préréglage sécurité ( ce qui revient à désactiver la fonction). Ce peut ê
Le quatrième paramètre (`security_default_on_percent`) est la valeur de `on_percent` qui sera utilisée lorsque le thermostat passe en mode ``security``. Si vous mettez `0` alors le thermostat sera coupé lorsqu'il passe en mode `security`, mettre 0,2% par exemple permet de garder un peu de chauffage (20% dans ce cas), même en mode ``security``. Ca évite de retrouver son logement totalement gelé lors d'une panne de thermomètre.
Le quatrième paramètre (`safety_default_on_percent`) est la valeur de `on_percent` qui sera utilisée lorsque le thermostat passe en mode ``security``. Si vous mettez `0` alors le thermostat sera coupé lorsqu'il passe en mode `security`, mettre 0,2% par exemple permet de garder un peu de chauffage (20% dans ce cas), même en mode ``security``. Ca évite de retrouver son logement totalement gelé lors d'une panne de thermomètre.
Il est possible de désactiver la mise en sécurité suite à une absence de données du thermomètre extérieure. En effet, celui-ci ayant la plupart du temps un impact faible sur la régulation (dépendant de votre paramètrage), il est possible qu'il soit absent sans mettre en danger le logement. Pour cela, il faut ajouter les lignes suivantes dans votre `configuration.yaml` :
```yaml
@@ -47,5 +47,5 @@ Par défaut, le thermomètre extérieur peut déclencher une mise en sécurité
> 1. Lorsque le capteur de température viendra à la vie et renverra les températures, le préréglage sera restauré à sa valeur précédente,
> 2. Attention, deux températures sont nécessaires : la température interne et la température externe et chacune doit donner la température, sinon le thermostat sera en préréglage "security",
> 3. Une action est disponible qui permet de régler les 3 paramètres de sécurité. Ca peut servir à adapter la fonction de sécurité à votre usage,
> 4. Pour un usage naturel, le ``security_default_on_percent`` doit être inférieur à ``security_min_on_percent``,
> 4. Pour un usage naturel, le ``safety_default_on_percent`` doit être inférieur à ``safety_min_on_percent``,
> 5. Si vous utilisez la carte Verstatile Thermostat UI (cf. [ici](additions.md#bien-mieux-avec-le-versatile-thermostat-ui-card)), un _Vtherm_ en mode sécurité est signalé par un voile grisatre qui donne le thermomètre en défaut et depuis combien de temps le thermomètre n'a pas remonté de valeur : ![mode sécurité](images/safety-mode-icon.png).

Binary file not shown.

Before

Width:  |  Height:  |  Size: 71 KiB

After

Width:  |  Height:  |  Size: 66 KiB

View File

@@ -678,14 +678,14 @@ Le formulaire de configuration avancée est le suivant :
Le premier délai (minimal_activation_delay_sec) en secondes est le délai minimum acceptable pour allumer le chauffage. Lorsque le calcul donne un délai de mise sous tension inférieur à cette valeur, le chauffage reste éteint.
Le deuxième délai (``security_delay_min``) est le délai maximal entre deux mesures de température avant de régler le préréglage sur ``security``. Si le capteur de température ne donne plus de mesures de température, le thermostat et le radiateur passeront en mode ``security`` après ce délai. Ceci est utile pour éviter une surchauffe si la batterie de votre capteur de température est trop faible.
Le deuxième délai (``safety_delay_min``) est le délai maximal entre deux mesures de température avant de régler le préréglage sur ``security``. Si le capteur de température ne donne plus de mesures de température, le thermostat et le radiateur passeront en mode ``security`` après ce délai. Ceci est utile pour éviter une surchauffe si la batterie de votre capteur de température est trop faible.
Le troisième paramétre (``security_min_on_percent``) est la valeur minimal de ``on_percent`` en dessous de laquelle le préréglage sécurité ne sera pas activé. Ce paramètre permet de ne pas mettre en sécurité un thermostat, si le radiateur piloté ne chauffe pas suffisament.
Le troisième paramétre (``safety_min_on_percent``) est la valeur minimal de ``on_percent`` en dessous de laquelle le préréglage sécurité ne sera pas activé. Ce paramètre permet de ne pas mettre en sécurité un thermostat, si le radiateur piloté ne chauffe pas suffisament.
Mettre ce paramètre à ``0.00`` déclenchera le préréglage sécurité quelque soit la dernière consigne de chauffage, à l'inverse ``1.00`` ne déclenchera jamais le préréglage sécurité ( ce qui revient à désactiver la fonction).
Le quatrième param§tre (``security_default_on_percent``) est la valeur de ``on_percent`` qui sera utilisée lorsque le thermostat passe en mode ``security``. Si vous mettez ``0`` alors le thermostat sera coupé lorsqu'il passe en mode ``security``, mettre 0,2% par exemple permet de garder un peu de chauffage (20% dans ce cas), même en mode ``security``. Ca évite de retrouver son logement totalement gelé lors d'une panne de thermomètre.
Le quatrième param§tre (``safety_default_on_percent``) est la valeur de ``on_percent`` qui sera utilisée lorsque le thermostat passe en mode ``security``. Si vous mettez ``0`` alors le thermostat sera coupé lorsqu'il passe en mode ``security``, mettre 0,2% par exemple permet de garder un peu de chauffage (20% dans ce cas), même en mode ``security``. Ca évite de retrouver son logement totalement gelé lors d'une panne de thermomètre.
Note: les paramètres `security_min_on_percent` et `security_default_on_percent` ne s'applique pas aux VTherms `over_climate`.
Note: les paramètres `safety_min_on_percent` et `safety_default_on_percent` ne s'applique pas aux VTherms `over_climate`.
Depuis la version 5.3 il est possible de désactiver la mise en sécurité suite à une absence de données du thermomètre extérieure. En effet, celui-ci ayant la plupart du temps un impact faible sur la régulation (dépendant de votre paramètrage), il est possible qu'il soit absent sans mettre en danger le logement. Pour cela, il faut ajouter les lignes suivantes dans votre `configuration.yaml` :
```
@@ -702,7 +702,7 @@ Voir [exemple de réglages](#examples-tuning) pour avoir des exemples de réglag
> 1. Lorsque le capteur de température viendra à la vie et renverra les températures, le préréglage sera restauré à sa valeur précédente,
> 2. Attention, deux températures sont nécessaires : la température interne et la température externe et chacune doit donner la température, sinon le thermostat sera en préréglage "security",
> 3. Un service est disponible qui permet de régler les 3 paramètres de sécurité. Ca peut servir à adapter la fonction de sécurité à votre usage,
> 4. Pour un usage naturel, le ``security_default_on_percent`` doit être inférieur à ``security_min_on_percent``,
> 4. Pour un usage naturel, le ``safety_default_on_percent`` doit être inférieur à ``safety_min_on_percent``,
> 5. Les thermostats de type ``thermostat_over_climate`` ne sont pas concernés par le mode security.
## Le contrôle centralisé
@@ -875,8 +875,8 @@ context:
| ``power_temp`` | Température si délestaqe | X | X | X | X |
| ``presence_sensor_entity_id`` | Capteur de présence entity id (true si quelqu'un est présent) | X | X | X | - |
| ``minimal_activation_delay`` | Délai minimal d'activation | X | - | - | X |
| ``security_delay_min`` | Délai maximal entre 2 mesures de températures | X | - | X | X |
| ``security_min_on_percent`` | Pourcentage minimal de puissance pour passer en mode sécurité | X | - | X | X |
| ``safety_delay_min`` | Délai maximal entre 2 mesures de températures | X | - | X | X |
| ``safety_min_on_percent`` | Pourcentage minimal de puissance pour passer en mode sécurité | X | - | X | X |
| ``auto_regulation_mode`` | Le mode d'auto-régulation | - | X | - | - |
| ``auto_regulation_dtemp`` | La seuil d'auto-régulation | - | X | - | - |
| ``auto_regulation_period_min`` | La période minimale d'auto-régulation | - | X | - | - |
@@ -902,9 +902,9 @@ context:
- minimal_activation_delay_sec : 300 secondes (à cause du temps de réponse)
## Le capteur de température alimenté par batterie
- security_delay_min : 60 min (parce que ces capteurs sont paresseux)
- security_min_on_percent : 0,5 (50% - on passe en preset ``security`` si le radiateur chauffait plus de 50% du temps)
- security_default_on_percent : 0,1 (10% - en preset ``security``, on garde un fond de chauffe de 20% du temps)
- safety_delay_min : 60 min (parce que ces capteurs sont paresseux)
- safety_min_on_percent : 0,5 (50% - on passe en preset ``security`` si le radiateur chauffait plus de 50% du temps)
- safety_default_on_percent : 0,1 (10% - en preset ``security``, on garde un fond de chauffe de 20% du temps)
Il faut comprendre ces réglages comme suit :
@@ -917,9 +917,9 @@ Ce qui est important c'est de ne pas prendre trop de risque avec ces paramètres
Versatile Thermostat vous permet d'être notifié lorsqu'un évènement de ce type survient. Mettez en place, les alertes qui vont bien dès l'utilisation de ce thermostat. Cf. (#notifications)
## Capteur de température réactif (sur secteur)
- security_delay_min : 15 min
- security_min_on_percent : 0,7 (70% - on passe en preset ``security`` si le radiateur chauffait plus de 70% du temps)
- security_default_on_percent : 0,25 (25% - en preset ``security``, on garde un fond de chauffe de 25% du temps)
- safety_delay_min : 15 min
- safety_min_on_percent : 0,7 (70% - on passe en preset ``security`` si le radiateur chauffait plus de 70% du temps)
- safety_default_on_percent : 0,25 (25% - en preset ``security``, on garde un fond de chauffe de 25% du temps)
## Mes presets
Ceci est juste un exemple de la façon dont j'utilise le préréglage. A vous de vous adapter à votre configuration mais cela peut être utile pour comprendre son fonctionnement.
@@ -1053,7 +1053,7 @@ Si le thermostat est en mode ``security`` les nouveaux paramètres sont appliqu
Pour changer les paramètres de sécurité utilisez le code suivant :
```
service : versatile_thermostat.set_security
service : versatile_thermostat.set_safety
data:
min_on_percent: "0.5"
default_on_percent: "0.1"
@@ -1082,7 +1082,7 @@ Les évènements notifiés sont les suivants:
- ``versatile_thermostat_security_event`` : un thermostat entre ou sort du preset ``security``
- ``versatile_thermostat_power_event`` : un thermostat entre ou sort du preset ``power``
- ``versatile_thermostat_temperature_event`` : une ou les deux mesures de température d'un thermostat n'ont pas été mis à jour depuis plus de `security_delay_min`` minutes
- ``versatile_thermostat_temperature_event`` : une ou les deux mesures de température d'un thermostat n'ont pas été mis à jour depuis plus de `safety_delay_min`` minutes
- ``versatile_thermostat_hvac_mode_event`` : le thermostat est allumé ou éteint. Cet évènement est aussi diffusé au démarrage du thermostat
- ``versatile_thermostat_preset_event`` : un nouveau preset est sélectionné sur le thermostat. Cet évènement est aussi diffusé au démarrage du thermostat
- ``versatile_thermostat_central_boiler_event`` : un évènement indiquant un changement dans l'état de la chaudière.
@@ -1126,13 +1126,13 @@ Les attributs personnalisés sont les suivants :
| ``saved_preset_mode`` | Le dernier preset utilisé avant le basculement automatique du preset |
| ``saved_target_temp`` | La dernière température utilisée avant la commutation automatique |
| ``window_state`` | Le dernier état connu du capteur de fenêtre. Aucun si la fenêtre n'est pas configurée |
| ``window_bypass_state`` | True si le bypass de la détection d'ouverture et activé |
| ``is_window_bypass`` | True si le bypass de la détection d'ouverture et activé |
| ``motion_state`` | Le dernier état connu du capteur de mouvement. Aucun si le mouvement n'est pas configuré |
| ``overpowering_state`` | Le dernier état connu du capteur surpuissant. Aucun si la gestion de l'alimentation n'est pas configurée |
| ``presence_state`` | Le dernier état connu du capteur de présence. Aucun si la gestion de présence n'est pas configurée |
| ``security_delay_min`` | Le délai avant d'activer le mode de sécurité lorsque un des 2 capteurs de température n'envoie plus de mesures |
| ``security_min_on_percent`` | Pourcentage de chauffe en dessous duquel le thermostat ne passera pas en sécurité |
| ``security_default_on_percent`` | Pourcentage de chauffe utilisé lorsque le thermostat est en sécurité |
| ``safety_delay_min`` | Le délai avant d'activer le mode de sécurité lorsque un des 2 capteurs de température n'envoie plus de mesures |
| ``safety_min_on_percent`` | Pourcentage de chauffe en dessous duquel le thermostat ne passera pas en sécurité |
| ``safety_default_on_percent`` | Pourcentage de chauffe utilisé lorsque le thermostat est en sécurité |
| ``last_temperature_datetime`` | La date et l'heure au format ISO8866 de la dernière réception de température interne |
| ``last_ext_temperature_datetime`` | La date et l'heure au format ISO8866 de la dernière réception de température extérieure |
| ``security_state`` | L'état de sécurité. vrai ou faux |
@@ -1571,9 +1571,9 @@ Ces paramètres sont sensibles et assez difficiles à régler. Merci de ne les u
<summary>Pourquoi mon Versatile Thermostat se met en Securite ?</summary>
## Pourquoi mon Versatile Thermostat se met en Securite ?
Le mode sécurité est possible sur tous les types de VTherm . Il survient lorsqu'un des 2 thermomètres qui donne la température de la pièce ou la température extérieure n'a pas envoyé de valeur depuis plus de `security_delay_min` minutes et que le radiateur chauffait à au moins `security_min_on_percent`.
Le mode sécurité est possible sur tous les types de VTherm . Il survient lorsqu'un des 2 thermomètres qui donne la température de la pièce ou la température extérieure n'a pas envoyé de valeur depuis plus de `safety_delay_min` minutes et que le radiateur chauffait à au moins `safety_min_on_percent`.
Comme l'algorithme est basé sur les mesures de température, si elles ne sont plus reçues par le VTherm, il y a un risque de surchauffe et d'incendie. Pour éviter ça, lorsque les conditions rappelées ci-dessus sont détectées, la chauffe est limité au paramètre `security_default_on_percent`. Cette valeur doit donc être raisonnablement faible (10% est une bonne valeur). Elle permet d'éviter un incendie tout en évitant de couper totalement le radiateur (risque de gel).
Comme l'algorithme est basé sur les mesures de température, si elles ne sont plus reçues par le VTherm, il y a un risque de surchauffe et d'incendie. Pour éviter ça, lorsque les conditions rappelées ci-dessus sont détectées, la chauffe est limité au paramètre `safety_default_on_percent`. Cette valeur doit donc être raisonnablement faible (10% est une bonne valeur). Elle permet d'éviter un incendie tout en évitant de couper totalement le radiateur (risque de gel).
Tous ces paramètres se règlent dans la dernière page de la configuration du VTherm : "Paramètres avancés".
@@ -1596,14 +1596,14 @@ last_temperature_datetime: "2023-12-06T18:43:28.346010+01:00"
last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00"
last_update_datetime: "2023-12-06T18:43:28.351103+01:00"
...
security_delay_min: 60
safety_delay_min: 60
```
On voit que :
1. le VTherm est bien en mode sécurité (`security_state: true`),
2. l'heure courante est le 06/12/2023 à 18h43:28 (`last_update_datetime: "2023-12-06T18:43:28.351103+01:00"`),
3. l'heure de dernière réception de la température intérieure est le 06/12/2023 à 18h43:28 (`last_temperature_datetime: "2023-12-06T18:43:28.346010+01:00"`). Elle est donc récente,
4. l'heure de dernière réception de la température extérieure est le 06/12/2023 à 13h04:35 (`last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00`). C'est donc l'heure extérieure qui a plus de 5 h de retard et qui a provoquée le passage en mode sécurité, car le seuil est limité à 60 min (`security_delay_min: 60`).
4. l'heure de dernière réception de la température extérieure est le 06/12/2023 à 13h04:35 (`last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00`). C'est donc l'heure extérieure qui a plus de 5 h de retard et qui a provoquée le passage en mode sécurité, car le seuil est limité à 60 min (`safety_delay_min: 60`).
### Comment être averti lorsque cela se produit ?
Pour être averti, le VTherm envoie un évènement dès que ça se produit et un en fin d'alerte sécurité. Vous pouvez capter ces évènements dans une automatisation et envoyer une notification par exemple, faire clignoter un voyant, déclencher une sirène, ... A vous de voir.
@@ -1613,8 +1613,8 @@ Pour manipuler les évènements générés par le VTherm, cf. [Eveènements](#ev
### Comment réparer ?
Cela va dépendre de la cause du problème :
1. Si un capteur est en défaut, il faut le réparer (remettre des piles, le changer, vérifier l'intégration Météo qui donne la température extérieure, ...),
2. Si le paramètre `security_delay_min` est trop petit, cela rsique de générer beaucoup de fausses alertes. Une valeur correcte est de l'ordre de 60 min, surtout si vous avez des capteurs de température à pile.
3. Certains capteurs de température, n'envoie pas de mesure si la température n'a pas changée. Donc en cas de température très stable pendant longtemps, le mode sécurité peut se déclencher. Ce n'est pas très grave puisqu'il s'enlève dès que le VTherm reçoit à nouveau une température. Sur certain thermomètre (TuYA par exemple), on peut forcer le délai max entre 2 mesures. Il conviendra de mettre un délai max < `security_delay_min`,
2. Si le paramètre `safety_delay_min` est trop petit, cela rsique de générer beaucoup de fausses alertes. Une valeur correcte est de l'ordre de 60 min, surtout si vous avez des capteurs de température à pile.
3. Certains capteurs de température, n'envoie pas de mesure si la température n'a pas changée. Donc en cas de température très stable pendant longtemps, le mode sécurité peut se déclencher. Ce n'est pas très grave puisqu'il s'enlève dès que le VTherm reçoit à nouveau une température. Sur certain thermomètre (TuYA par exemple), on peut forcer le délai max entre 2 mesures. Il conviendra de mettre un délai max < `safety_delay_min`,
4. Dès que la température sera a nouveau reçue le mode sécurité s'enlèvera et les valeurs précédentes de preset, température cible et mode seront restaurées.
</details>

View File

@@ -61,8 +61,8 @@
| ``power_temp`` | Température si délestaqe | X | X | X | X |
| ``presence_sensor_entity_id`` | Capteur de présence entity id (true si quelqu'un est présent) | X | X | X | - |
| ``minimal_activation_delay`` | Délai minimal d'activation | X | - | - | X |
| ``security_delay_min`` | Délai maximal entre 2 mesures de températures | X | - | X | X |
| ``security_min_on_percent`` | Pourcentage minimal de puissance pour passer en mode sécurité | X | - | X | X |
| ``safety_delay_min`` | Délai maximal entre 2 mesures de températures | X | - | X | X |
| ``safety_min_on_percent`` | Pourcentage minimal de puissance pour passer en mode sécurité | X | - | X | X |
| ``auto_regulation_mode`` | Le mode d'auto-régulation | - | X | - | - |
| ``auto_regulation_dtemp`` | La seuil d'auto-régulation | - | X | - | - |
| ``auto_regulation_period_min`` | La période minimale d'auto-régulation | - | X | - | - |
@@ -173,7 +173,7 @@ Si le thermostat est en mode ``security`` les nouveaux paramètres sont appliqu
Pour changer les paramètres de sécurité utilisez le code suivant :
```yaml
service : versatile_thermostat.set_security
service : versatile_thermostat.set_safety
data:
min_on_percent: "0.5"
default_on_percent: "0.1"
@@ -202,7 +202,7 @@ Les évènements notifiés sont les suivants:
- ``versatile_thermostat_security_event`` : un thermostat entre ou sort du preset ``security``
- ``versatile_thermostat_power_event`` : un thermostat entre ou sort du preset ``power``
- ``versatile_thermostat_temperature_event`` : une ou les deux mesures de température d'un thermostat n'ont pas été mis à jour depuis plus de `security_delay_min`` minutes
- ``versatile_thermostat_temperature_event`` : une ou les deux mesures de température d'un thermostat n'ont pas été mis à jour depuis plus de `safety_delay_min`` minutes
- ``versatile_thermostat_hvac_mode_event`` : le thermostat est allumé ou éteint. Cet évènement est aussi diffusé au démarrage du thermostat
- ``versatile_thermostat_preset_event`` : un nouveau preset est sélectionné sur le thermostat. Cet évènement est aussi diffusé au démarrage du thermostat
- ``versatile_thermostat_central_boiler_event`` : un évènement indiquant un changement dans l'état de la chaudière.
@@ -247,13 +247,13 @@ Les attributs personnalisés sont les suivants :
| ``saved_preset_mode`` | Le dernier preset utilisé avant le basculement automatique du preset |
| ``saved_target_temp`` | La dernière température utilisée avant la commutation automatique |
| ``window_state`` | Le dernier état connu du capteur de fenêtre. Aucun si la fenêtre n'est pas configurée |
| ``window_bypass_state`` | True si le bypass de la détection d'ouverture et activé |
| ``is_window_bypass`` | True si le bypass de la détection d'ouverture et activé |
| ``motion_state`` | Le dernier état connu du capteur de mouvement. Aucun si le mouvement n'est pas configuré |
| ``overpowering_state`` | Le dernier état connu du capteur surpuissant. Aucun si la gestion de l'alimentation n'est pas configurée |
| ``presence_state`` | Le dernier état connu du capteur de présence. Aucun si la gestion de présence n'est pas configurée |
| ``security_delay_min`` | Le délai avant d'activer le mode de sécurité lorsque un des 2 capteurs de température n'envoie plus de mesures |
| ``security_min_on_percent`` | Pourcentage de chauffe en dessous duquel le thermostat ne passera pas en sécurité |
| ``security_default_on_percent`` | Pourcentage de chauffe utilisé lorsque le thermostat est en sécurité |
| ``safety_delay_min`` | Le délai avant d'activer le mode de sécurité lorsque un des 2 capteurs de température n'envoie plus de mesures |
| ``safety_min_on_percent`` | Pourcentage de chauffe en dessous duquel le thermostat ne passera pas en sécurité |
| ``safety_default_on_percent`` | Pourcentage de chauffe utilisé lorsque le thermostat est en sécurité |
| ``last_temperature_datetime`` | La date et l'heure au format ISO8866 de la dernière réception de température interne |
| ``last_ext_temperature_datetime`` | La date et l'heure au format ISO8866 de la dernière réception de température extérieure |
| ``security_state`` | L'état de sécurité. vrai ou faux |
@@ -270,5 +270,8 @@ Les attributs personnalisés sont les suivants :
| ``auto_start_stop_enable`` | Indique si le VTherm est autorisé à s'auto démarrer/arrêter |
| ``auto_start_stop_level`` | Indique le niveau d'auto start/stop |
| ``hvac_off_reason`` | Indique la raison de l'arrêt (hvac_off) du VTherm. Ce peut être Window, Auto-start/stop ou Manuel |
| ``last_change_time_from_vtherm`` | La date/heure du dernier changement fait par VTherm |
| ``nb_device_actives`` | Le nombre de devices sous-jacents actuellement vus comme actifs |
| ``device_actives`` | La liste des devices sous-jacents actuellement vus comme actifs |
Ces attributs vous seront demandés lors d'une demande d'aide.

View File

@@ -32,7 +32,8 @@ Elle permet de configurer les entités de contrôle de la vanne :
Vous devez donner :
1. autant d'entités de contrôle d'ouverture de la vanne qu'il y a de sous-jacents et dans le même odre. Ces paramètres sont obligatoires,
2. autant d'entités de calibrage du décalage de température qu'il y a de sous-jacents et dans le même ordre. Ces paramètres sont facultatifs ; ils doivent être tous founis ou aucun,
3. autant d'entités de de contrôile du taux de fermture qu'il y a de sous-jacents et dans le même ordre. Ces paramètres sont facultatifs ; ils doivent être tous founis ou aucun
3. autant d'entités de de contrôile du taux de fermture qu'il y a de sous-jacents et dans le même ordre. Ces paramètres sont facultatifs ; ils doivent être tous founis ou aucun,
4. une liste de valeurs minimales d'ouverture de la vanne lorsqu'elle doit être ouverte. Ce champ est une liste d'entier. Si la vanne doit être ouverte, elle le sera au minimum avec cette valeur d'ouverture. Cela permet de laisser passer suffisamment d'eau lorsqu'elle doit être ouverte.
L'algorithme de calcul du taux d'ouverture est basé sur le _TPI_ qui est décrit [ici](algorithms.md). C'est le même algorithme qui est utilisé pour les _VTherm_ `over_switch` et `over_valve`.

View File

@@ -15,6 +15,7 @@
- [Comment réparer ?](#comment-réparer-)
- [Utilisation d'un groupe de personnes comme capteur de présence](#utilisation-dun-groupe-de-personnes-comme-capteur-de-présence)
- [Activer les logs du Versatile Thermostat](#activer-les-logs-du-versatile-thermostat)
- [VTherm ne suit pas les changements de consigne faits directement depuis le sous-jacents (`over_climate`)](#vtherm-ne-suit-pas-les-changements-de-consigne-faits-directement-depuis-le-sous-jacents-over_climate)
## Utilisation d'un Heatzy
@@ -122,9 +123,9 @@ versatile_thermostat:
Ces paramètres sont sensibles et assez difficiles à régler. Merci de ne les utiliser que si vous savez ce que vous faites et que vos mesures de température ne sont pas déjà lisses.
## Pourquoi mon Versatile Thermostat se met en Securite ?
Le mode sécurité est possible sur les types de VTherm de type `over_switch` et `over_valve` uniquement. Il survient lorsqu'un des 2 thermomètres qui donne la température de la pièce ou la température extérieure n'a pas envoyé de valeur depuis plus de `security_delay_min` minutes et que le radiateur chauffait à au moins `security_min_on_percent`. Cf. [mode sécurité](feature-advanced.md#la-mise-en-sécurité)
Le mode sécurité est possible sur les types de VTherm de type `over_switch` et `over_valve` uniquement. Il survient lorsqu'un des 2 thermomètres qui donne la température de la pièce ou la température extérieure n'a pas envoyé de valeur depuis plus de `safety_delay_min` minutes et que le radiateur chauffait à au moins `safety_min_on_percent`. Cf. [mode sécurité](feature-advanced.md#la-mise-en-sécurité)
Comme l'algorithme est basé sur les mesures de température, si elles ne sont plus reçues par le VTherm, il y a un risque de surchauffe et d'incendie. Pour éviter ça, lorsque les conditions rappelées ci-dessus sont détectées, la chauffe est limité au paramètre `security_default_on_percent`. Cette valeur doit donc être raisonnablement faible (10% est une bonne valeur). Elle permet d'éviter un incendie tout en évitant de couper totalement le radiateur (risque de gel).
Comme l'algorithme est basé sur les mesures de température, si elles ne sont plus reçues par le VTherm, il y a un risque de surchauffe et d'incendie. Pour éviter ça, lorsque les conditions rappelées ci-dessus sont détectées, la chauffe est limité au paramètre `safety_default_on_percent`. Cette valeur doit donc être raisonnablement faible (10% est une bonne valeur). Elle permet d'éviter un incendie tout en évitant de couper totalement le radiateur (risque de gel).
Tous ces paramètres se règlent dans la dernière page de la configuration du VTherm : "Paramètres avancés".
@@ -148,14 +149,14 @@ last_temperature_datetime: "2023-12-06T18:43:28.346010+01:00"
last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00"
last_update_datetime: "2023-12-06T18:43:28.351103+01:00"
...
security_delay_min: 60
safety_delay_min: 60
```
On voit que :
1. le VTherm est bien en mode sécurité (`security_state: true`),
2. l'heure courante est le 06/12/2023 à 18h43:28 (`last_update_datetime: "2023-12-06T18:43:28.351103+01:00"`),
3. l'heure de dernière réception de la température intérieure est le 06/12/2023 à 18h43:28 (`last_temperature_datetime: "2023-12-06T18:43:28.346010+01:00"`). Elle est donc récente,
4. l'heure de dernière réception de la température extérieure est le 06/12/2023 à 13h04:35 (`last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00`). C'est donc l'heure extérieure qui a plus de 5 h de retard et qui a provoquée le passage en mode sécurité, car le seuil est limité à 60 min (`security_delay_min: 60`).
4. l'heure de dernière réception de la température extérieure est le 06/12/2023 à 13h04:35 (`last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00`). C'est donc l'heure extérieure qui a plus de 5 h de retard et qui a provoquée le passage en mode sécurité, car le seuil est limité à 60 min (`safety_delay_min: 60`).
### Comment être averti lorsque cela se produit ?
Pour être averti, le VTherm envoie un évènement dès que ça se produit et un en fin d'alerte sécurité. Vous pouvez capter ces évènements dans une automatisation et envoyer une notification par exemple, faire clignoter un voyant, déclencher une sirène, ... A vous de voir.
@@ -165,8 +166,8 @@ Pour manipuler les évènements générés par le VTherm, cf. [Eveènements](#ev
### Comment réparer ?
Cela va dépendre de la cause du problème :
1. Si un capteur est en défaut, il faut le réparer (remettre des piles, le changer, vérifier l'intégration Météo qui donne la température extérieure, ...),
2. Si le paramètre `security_delay_min` est trop petit, cela risque de générer beaucoup de fausses alertes. Une valeur correcte est de l'ordre de 60 min, surtout si vous avez des capteurs de température à pile. Cf [mes réglages](tuning-examples.md#le-capteur-de-température-alimenté-par-batterie)
3. Certains capteurs de température, n'envoie pas de mesure si la température n'a pas changée. Donc en cas de température très stable pendant longtemps, le mode sécurité peut se déclencher. Ce n'est pas très grave puisqu'il s'enlève dès que le VTherm reçoit à nouveau une température. Sur certain thermomètre (TuYA par exemple ou Zigbee), on peut forcer le délai max entre 2 mesures. Il conviendra de mettre un délai max < `security_delay_min`,
2. Si le paramètre `safety_delay_min` est trop petit, cela risque de générer beaucoup de fausses alertes. Une valeur correcte est de l'ordre de 60 min, surtout si vous avez des capteurs de température à pile. Cf [mes réglages](tuning-examples.md#le-capteur-de-température-alimenté-par-batterie)
3. Certains capteurs de température, n'envoie pas de mesure si la température n'a pas changée. Donc en cas de température très stable pendant longtemps, le mode sécurité peut se déclencher. Ce n'est pas très grave puisqu'il s'enlève dès que le VTherm reçoit à nouveau une température. Sur certain thermomètre (TuYA par exemple ou Zigbee), on peut forcer le délai max entre 2 mesures. Il conviendra de mettre un délai max < `safety_delay_min`,
4. Dès que la température sera a nouveau reçue le mode sécurité s'enlèvera et les valeurs précédentes de preset, température cible et mode seront restaurées.
5. Si c'est le capteur de température extérieur qui est en défaut, vous pouvez désactiver le déclenchement du mode sécurité puisqu'il influe assez peu sur le résultat. Pour ce faire, cf. [ici](feature-advanced.md#la-mise-en-sécurité)
@@ -205,4 +206,8 @@ logs:
```
Vous devez recharger la configuration yaml (Outils de dev / Yaml / Toute la configuration Yaml) ou redémarrer Home Assistant pour que ce changement soit pris en compte.
Attention, en mode debug Versatile Thermostat est très verbeux et peut vite ralentir Home Assistant ou saturer votre disque dur. Si vous passez en mode debug pour une analyse d'anomalie il faut s'y mettre juste le temps de reproduire le bug et désactiver le mode debug juste après.
Attention, en mode debug Versatile Thermostat est très verbeux et peut vite ralentir Home Assistant ou saturer votre disque dur. Si vous passez en mode debug pour une analyse d'anomalie il faut s'y mettre juste le temps de reproduire le bug et désactiver le mode debug juste après.
## VTherm ne suit pas les changements de consigne faits directement depuis le sous-jacents (`over_climate`)
Voir le détail de cette fonction [ici](over-climate.md#suivre-les-changements-de-température-du-sous-jacent).

View File

@@ -18,9 +18,9 @@
## Le capteur de température alimenté par batterie
Ces capteurs sont souvent paresseux et n'envoit pas toujours de mesure de température lorsqu'elle est stable. Par conséquent, les réglages doivent être laches pour éviter les faux positifs.
- security_delay_min : 60 min (parce que ces capteurs sont paresseux)
- security_min_on_percent : 0,7 (70% - on passe en mode sécurité si le radiateur chauffait plus de 70% du temps)
- security_default_on_percent : 0,4 (40% - en mode sécurité, on garde un fond de chauffe de 40% du temps pour éviter d'avoir trop froid)
- safety_delay_min : 60 min (parce que ces capteurs sont paresseux)
- safety_min_on_percent : 0,7 (70% - on passe en mode sécurité si le radiateur chauffait plus de 70% du temps)
- safety_default_on_percent : 0,4 (40% - en mode sécurité, on garde un fond de chauffe de 40% du temps pour éviter d'avoir trop froid)
Il faut comprendre ces réglages comme suit :
@@ -34,9 +34,9 @@ Versatile Thermostat vous permet d'être notifié lorsqu'un évènement de ce ty
## Capteur de température réactif (sur secteur)
Un thermomètre alimenté est censé est très régulier dans l'envoi des températures. Si il n'envoie rien pendant 15 min, il a certainement un soucis et on peut réagir plus vite sans risque de faux positif.
- security_delay_min : 15 min
- security_min_on_percent : 0,5 (50% - on passe en preset ``security`` si le radiateur chauffait plus de 50% du temps)
- security_default_on_percent : 0,25 (20% - en preset ``security``, on garde un fond de chauffe de 20% du temps)
- safety_delay_min : 15 min
- safety_min_on_percent : 0,5 (50% - on passe en preset ``security`` si le radiateur chauffait plus de 50% du temps)
- safety_default_on_percent : 0,25 (20% - en preset ``security``, on garde un fond de chauffe de 20% du temps)
## Mes presets

12
faq.md
View File

@@ -153,9 +153,9 @@ Ces paramètres sont sensibles et assez difficiles à régler. Merci de ne les u
<summary>Pourquoi mon Versatile Thermostat se met en Securite ?</summary>
## Pourquoi mon Versatile Thermostat se met en Securite ?
Le mode sécurité est possible sur tous les types de VTherm . Il survient lorsqu'un des 2 thermomètres qui donne la température de la pièce ou la température extérieure n'a pas envoyé de valeur depuis plus de `security_delay_min` minutes et que le radiateur chauffait à au moins `security_min_on_percent`.
Le mode sécurité est possible sur tous les types de VTherm . Il survient lorsqu'un des 2 thermomètres qui donne la température de la pièce ou la température extérieure n'a pas envoyé de valeur depuis plus de `safety_delay_min` minutes et que le radiateur chauffait à au moins `safety_min_on_percent`.
Comme l'algorithme est basé sur les mesures de température, si elles ne sont plus reçues par le VTherm, il y a un risque de surchauffe et d'incendie. Pour éviter ça, lorsque les conditions rappelées ci-dessus sont détectées, la chauffe est limité au paramètre `security_default_on_percent`. Cette valeur doit donc être raisonnablement faible (10% est une bonne valeur). Elle permet d'éviter un incendie tout en évitant de couper totalement le radiateur (risque de gel).
Comme l'algorithme est basé sur les mesures de température, si elles ne sont plus reçues par le VTherm, il y a un risque de surchauffe et d'incendie. Pour éviter ça, lorsque les conditions rappelées ci-dessus sont détectées, la chauffe est limité au paramètre `safety_default_on_percent`. Cette valeur doit donc être raisonnablement faible (10% est une bonne valeur). Elle permet d'éviter un incendie tout en évitant de couper totalement le radiateur (risque de gel).
Tous ces paramètres se règlent dans la dernière page de la configuration du VTherm : "Paramètres avancés".
@@ -178,14 +178,14 @@ last_temperature_datetime: "2023-12-06T18:43:28.346010+01:00"
last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00"
last_update_datetime: "2023-12-06T18:43:28.351103+01:00"
...
security_delay_min: 60
safety_delay_min: 60
```
On voit que :
1. le VTherm est bien en mode sécurité (`security_state: true`),
2. l'heure courante est le 06/12/2023 à 18h43:28 (`last_update_datetime: "2023-12-06T18:43:28.351103+01:00"`),
3. l'heure de dernière réception de la température intérieure est le 06/12/2023 à 18h43:28 (`last_temperature_datetime: "2023-12-06T18:43:28.346010+01:00"`). Elle est donc récente,
4. l'heure de dernière réception de la température extérieure est le 06/12/2023 à 13h04:35 (`last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00`). C'est donc l'heure extérieure qui a plus de 5 h de retard et qui a provoquée le passage en mode sécurité, car le seuil est limité à 60 min (`security_delay_min: 60`).
4. l'heure de dernière réception de la température extérieure est le 06/12/2023 à 13h04:35 (`last_ext_temperature_datetime: "2023-12-06T13:04:35.164367+01:00`). C'est donc l'heure extérieure qui a plus de 5 h de retard et qui a provoquée le passage en mode sécurité, car le seuil est limité à 60 min (`safety_delay_min: 60`).
### Comment être averti lorsque cela se produit ?
Pour être averti, le VTherm envoie un évènement dès que ça se produit et un en fin d'alerte sécurité. Vous pouvez capter ces évènements dans une automatisation et envoyer une notification par exemple, faire clignoter un voyant, déclencher une sirène, ... A vous de voir.
@@ -195,8 +195,8 @@ Pour manipuler les évènements générés par le VTherm, cf. [Eveènements](#ev
### Comment réparer ?
Cela va dépendre de la cause du problème :
1. Si un capteur est en défaut, il faut le réparer (remettre des piles, le changer, vérifier l'intégration Météo qui donne la température extérieure, ...),
2. Si le paramètre `security_delay_min` est trop petit, cela rsique de générer beaucoup de fausses alertes. Une valeur correcte est de l'ordre de 60 min, surtout si vous avez des capteurs de température à pile.
3. Certains capteurs de température, n'envoie pas de mesure si la température n'a pas changée. Donc en cas de température très stable pendant longtemps, le mode sécurité peut se déclencher. Ce n'est pas très grave puisqu'il s'enlève dès que le VTherm reçoit à nouveau une température. Sur certain thermomètre (TuYA par exemple), on peut forcer le délai max entre 2 mesures. Il conviendra de mettre un délai max < `security_delay_min`,
2. Si le paramètre `safety_delay_min` est trop petit, cela rsique de générer beaucoup de fausses alertes. Une valeur correcte est de l'ordre de 60 min, surtout si vous avez des capteurs de température à pile.
3. Certains capteurs de température, n'envoie pas de mesure si la température n'a pas changée. Donc en cas de température très stable pendant longtemps, le mode sécurité peut se déclencher. Ce n'est pas très grave puisqu'il s'enlève dès que le VTherm reçoit à nouveau une température. Sur certain thermomètre (TuYA par exemple), on peut forcer le délai max entre 2 mesures. Il conviendra de mettre un délai max < `safety_delay_min`,
4. Dès que la température sera a nouveau reçue le mode sécurité s'enlèvera et les valeurs précédentes de preset, température cible et mode seront restaurées.
</details>

View File

@@ -3,5 +3,5 @@
"content_in_root": false,
"render_readme": true,
"hide_default_branch": false,
"homeassistant": "2024.10.4"
"homeassistant": "2024.12.4"
}

View File

@@ -1 +1 @@
homeassistant==2024.10.4
homeassistant==2024.12.3

View File

@@ -1,4 +1,4 @@
# pylint: disable=wildcard-import, unused-wildcard-import, protected-access, unused-argument, line-too-long, abstract-method, too-many-lines, redefined-builtin
# pylint: disable=wildcard-import, unused-wildcard-import, unused-import, protected-access, unused-argument, line-too-long, abstract-method, too-many-lines, redefined-builtin
""" Some common resources """
import asyncio
@@ -8,7 +8,16 @@ from unittest.mock import patch, MagicMock # pylint: disable=unused-import
import pytest # pylint: disable=unused-import
from homeassistant.core import HomeAssistant, Event, EVENT_STATE_CHANGED, State
from homeassistant.const import UnitOfTemperature, STATE_ON, STATE_OFF, ATTR_TEMPERATURE
from homeassistant.const import (
UnitOfTemperature,
STATE_ON,
STATE_OFF,
ATTR_TEMPERATURE,
STATE_UNAVAILABLE,
STATE_UNKNOWN,
STATE_HOME,
STATE_NOT_HOME,
)
from homeassistant.config_entries import ConfigEntryState
from homeassistant.helpers.entity import Entity
@@ -188,9 +197,9 @@ FULL_CENTRAL_CONFIG = {
CONF_PRESENCE_SENSOR: "binary_sensor.mock_presence_sensor",
CONF_PRESET_POWER: 14,
CONF_MINIMAL_ACTIVATION_DELAY: 11,
CONF_SECURITY_DELAY_MIN: 61,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.2,
CONF_SAFETY_DELAY_MIN: 61,
CONF_SAFETY_MIN_ON_PERCENT: 0.5,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.2,
CONF_USE_CENTRAL_BOILER_FEATURE: False,
}
@@ -229,9 +238,9 @@ FULL_CENTRAL_CONFIG_WITH_BOILER = {
CONF_MAX_POWER_SENSOR: "sensor.mock_max_power_sensor",
CONF_PRESET_POWER: 14,
CONF_MINIMAL_ACTIVATION_DELAY: 11,
CONF_SECURITY_DELAY_MIN: 61,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.2,
CONF_SAFETY_DELAY_MIN: 61,
CONF_SAFETY_MIN_ON_PERCENT: 0.5,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.2,
CONF_USE_CENTRAL_BOILER_FEATURE: True,
CONF_CENTRAL_BOILER_ACTIVATION_SRV: "switch.pompe_chaudiere/switch.turn_on",
CONF_CENTRAL_BOILER_DEACTIVATION_SRV: "switch.pompe_chaudiere/switch.turn_off",
@@ -579,6 +588,7 @@ class MockNumber(NumberEntity):
def set_native_value(self, value: float):
"""Change the value"""
self._attr_native_value = value
self.async_write_ha_state()
async def create_thermostat(
@@ -589,12 +599,7 @@ async def create_thermostat(
await hass.config_entries.async_setup(entry.entry_id)
assert entry.state is ConfigEntryState.LOADED
# We should reload the VTherm links
# vtherm_api: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api()
# central_config = vtherm_api.find_central_configuration()
entity = search_entity(hass, entity_id, CLIMATE_DOMAIN)
# if entity and hasattr(entity, "init_presets")::
# await entity.init_presets(central_config)
return entity
@@ -736,7 +741,7 @@ async def send_power_change_event(entity: BaseThermostat, new_power, date, sleep
)
},
)
await entity._async_power_changed(power_event)
await entity.power_manager._async_power_sensor_changed(power_event)
if sleep:
await asyncio.sleep(0.1)
@@ -762,7 +767,7 @@ async def send_max_power_change_event(
)
},
)
await entity._async_max_power_changed(power_event)
await entity.power_manager._async_max_power_sensor_changed(power_event)
if sleep:
await asyncio.sleep(0.1)
@@ -795,7 +800,7 @@ async def send_window_change_event(
),
},
)
ret = await entity._async_windows_changed(window_event)
ret = await entity.window_manager._window_sensor_changed(window_event)
if sleep:
await asyncio.sleep(0.1)
return ret
@@ -829,14 +834,14 @@ async def send_motion_change_event(
),
},
)
ret = await entity._async_motion_changed(motion_event)
ret = await entity.motion_manager._motion_sensor_changed(motion_event)
if sleep:
await asyncio.sleep(0.1)
return ret
async def send_presence_change_event(
entity: BaseThermostat, new_state: bool, old_state: bool, date, sleep=True
vtherm: BaseThermostat, new_state: bool, old_state: bool, date, sleep=True
):
"""Sending a new presence event simulating a change on the window state"""
_LOGGER.info(
@@ -844,26 +849,26 @@ async def send_presence_change_event(
new_state,
old_state,
date,
entity,
vtherm,
)
presence_event = Event(
EVENT_STATE_CHANGED,
{
"new_state": State(
entity_id=entity.entity_id,
entity_id=vtherm.entity_id,
state=STATE_ON if new_state else STATE_OFF,
last_changed=date,
last_updated=date,
),
"old_state": State(
entity_id=entity.entity_id,
entity_id=vtherm.entity_id,
state=STATE_ON if old_state else STATE_OFF,
last_changed=date,
last_updated=date,
),
},
)
ret = await entity._async_presence_changed(presence_event)
ret = await vtherm._presence_manager._presence_sensor_changed(presence_event)
if sleep:
await asyncio.sleep(0.1)
return ret
@@ -999,7 +1004,7 @@ async def set_climate_preset_temp(
await temp_entity.async_set_native_value(temp)
else:
_LOGGER.warning(
"commons tests set_cliamte_preset_temp: cannot find number entity with entity_id '%s'",
"commons tests set_climate_preset_temp: cannot find number entity with entity_id '%s'",
number_entity_id,
)
@@ -1061,9 +1066,14 @@ async def set_all_climate_preset_temp(
NUMBER_DOMAIN,
)
assert temp_entity
if not temp_entity:
raise ConfigurationNotCompleteError(
f"'{number_entity_name}' don't exists as number entity"
)
# Because set_value is not implemented in Number class (really don't understand why...)
assert temp_entity.state == value
await hass.async_block_till_done()
#
# Side effects management

View File

@@ -89,7 +89,12 @@ MOCK_TH_OVER_SWITCH_AC_TYPE_CONFIG = {
}
MOCK_TH_OVER_4SWITCH_TYPE_CONFIG = {
CONF_UNDERLYING_LIST: ["switch.mock_4switch0", "switch.mock_4switch1","switch.mock_4switch2","switch.mock_4switch3"],
CONF_UNDERLYING_LIST: [
"switch.mock_4switch0",
"switch.mock_4switch1",
"switch.mock_4switch2",
"switch.mock_4switch3",
],
CONF_HEATER_KEEP_ALIVE: 0,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_AC_MODE: False,
@@ -195,9 +200,9 @@ MOCK_PRESENCE_AC_CONFIG = {
MOCK_ADVANCED_CONFIG = {
CONF_MINIMAL_ACTIVATION_DELAY: 10,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.4,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.4,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.3,
}
MOCK_DEFAULT_FEATURE_CONFIG = {

View File

@@ -53,8 +53,8 @@ async def test_over_climate_auto_fan_mode_turbo(
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
},
)
@@ -119,8 +119,8 @@ async def test_over_climate_auto_fan_mode_not_turbo(
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
},
)
@@ -189,8 +189,8 @@ async def test_over_climate_auto_fan_mode_turbo_activation(
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True,
},

View File

@@ -309,7 +309,7 @@ async def test_over_climate_regulation_limitations(
assert entity.hvac_action == HVACAction.HEATING
# the regulated temperature will not change because when we set temp manually it is forced
assert entity.regulated_target_temp == 17 # 19.5
assert entity.regulated_target_temp == 19.5
# 2. set manual target temp (at now - 18) -> the regulation should be taken into account
event_timestamp = now - timedelta(minutes=18)

View File

@@ -1,4 +1,4 @@
# pylint: disable=wildcard-import, unused-wildcard-import, protected-access, unused-argument, line-too-long, unused-variable
# pylint: disable=wildcard-import, unused-wildcard-import, protected-access, unused-argument, line-too-long, unused-variable, too-many-lines
""" Test the Auto Start Stop algorithm management """
from datetime import datetime, timedelta
@@ -335,8 +335,8 @@ async def test_auto_start_stop_none_vtherm(
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True,
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_NONE,
@@ -363,15 +363,14 @@ async def test_auto_start_stop_none_vtherm(
# Initialize all temps
await set_all_climate_preset_temp(hass, vtherm, temps, "overclimate")
# Check correct initialization of auto_start_stop attributes
assert (
vtherm._attr_extra_state_attributes["auto_start_stop_level"]
== AUTO_START_STOP_LEVEL_NONE
)
assert vtherm._attr_extra_state_attributes["auto_start_stop_dtmin"] is None
assert vtherm._attr_extra_state_attributes.get("auto_start_stop_level") is None
assert vtherm._attr_extra_state_attributes.get("auto_start_stop_dtmin") is None
# 1. Vtherm auto-start/stop should be in NONE mode
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_NONE
assert (
vtherm.auto_start_stop_manager.auto_start_stop_level
== AUTO_START_STOP_LEVEL_NONE
)
# 2. We should not find any switch Enable entity
assert (
@@ -427,8 +426,8 @@ async def test_auto_start_stop_medium_heat_vtherm(
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True,
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_MEDIUM,
@@ -464,7 +463,10 @@ async def test_auto_start_stop_medium_heat_vtherm(
assert vtherm._attr_extra_state_attributes["auto_start_stop_dtmin"] == 15
# 1. Vtherm auto-start/stop should be in MEDIUM mode and an enable entity should exists
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_MEDIUM
assert (
vtherm.auto_start_stop_manager.auto_start_stop_level
== AUTO_START_STOP_LEVEL_MEDIUM
)
enable_entity = search_entity(
hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN
)
@@ -488,7 +490,7 @@ async def test_auto_start_stop_medium_heat_vtherm(
# 3. Set current temperature to 19 5 min later
now = now + timedelta(minutes=5)
# reset accumulated error (only for testing)
vtherm._auto_start_stop_algo._accumulated_error = 0
vtherm.auto_start_stop_manager._auto_start_stop_algo._accumulated_error = 0
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event:
@@ -500,7 +502,7 @@ async def test_auto_start_stop_medium_heat_vtherm(
assert vtherm.hvac_mode == HVACMode.HEAT
assert mock_send_event.call_count == 0
assert (
vtherm._auto_start_stop_algo.accumulated_error == 0
vtherm.auto_start_stop_manager._auto_start_stop_algo.accumulated_error == 0
) # target = current = 19
# 4. Set current temperature to 20 5 min later
@@ -516,7 +518,10 @@ async def test_auto_start_stop_medium_heat_vtherm(
assert vtherm.hvac_mode == HVACMode.HEAT
assert mock_send_event.call_count == 0
# accumulated_error = target - current = -1 x 5 min / 2
assert vtherm._auto_start_stop_algo.accumulated_error == -2.5
assert (
vtherm.auto_start_stop_manager._auto_start_stop_algo.accumulated_error
== -2.5
)
# 5. Set current temperature to 21 5 min later -> should turn off
now = now + timedelta(minutes=5)
@@ -532,7 +537,9 @@ async def test_auto_start_stop_medium_heat_vtherm(
assert vtherm.hvac_off_reason == HVAC_OFF_REASON_AUTO_START_STOP
# accumulated_error = -2.5 + target - current = -2 x 5 min / 2 capped to 5
assert vtherm._auto_start_stop_algo.accumulated_error == -5
assert (
vtherm.auto_start_stop_manager._auto_start_stop_algo.accumulated_error == -5
)
# a message should have been sent
assert mock_send_event.call_count >= 1
@@ -577,7 +584,9 @@ async def test_auto_start_stop_medium_heat_vtherm(
await hass.async_block_till_done()
# accumulated_error = .... capped to -5
assert vtherm._auto_start_stop_algo.accumulated_error == -5
assert (
vtherm.auto_start_stop_manager._auto_start_stop_algo.accumulated_error == -5
)
# VTherm should stay stopped cause slope is too low to allow the turn to On
assert vtherm.hvac_mode == HVACMode.OFF
@@ -593,7 +602,9 @@ async def test_auto_start_stop_medium_heat_vtherm(
await hass.async_block_till_done()
# accumulated_error = -5/2 + target - current = 1 x 20 min / 2 capped to 5
assert vtherm._auto_start_stop_algo.accumulated_error == 5
assert (
vtherm.auto_start_stop_manager._auto_start_stop_algo.accumulated_error == 5
)
# VTherm should have been stopped
assert vtherm.hvac_mode == HVACMode.HEAT
@@ -680,8 +691,8 @@ async def test_auto_start_stop_fast_ac_vtherm(
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
CONF_UNDERLYING_LIST: ["climate.mock_climate"],
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True,
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_FAST,
@@ -717,7 +728,10 @@ async def test_auto_start_stop_fast_ac_vtherm(
assert vtherm._attr_extra_state_attributes["auto_start_stop_dtmin"] == 7
# 1. Vtherm auto-start/stop should be in MEDIUM mode
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_FAST
assert (
vtherm.auto_start_stop_manager.auto_start_stop_level
== AUTO_START_STOP_LEVEL_FAST
)
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
@@ -736,7 +750,7 @@ async def test_auto_start_stop_fast_ac_vtherm(
# 3. Set current temperature to 19 5 min later
now = now + timedelta(minutes=5)
# reset accumulated error for test
vtherm._auto_start_stop_algo._accumulated_error = 0
vtherm.auto_start_stop_manager._auto_start_stop_algo._accumulated_error = 0
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event:
@@ -748,7 +762,8 @@ async def test_auto_start_stop_fast_ac_vtherm(
assert vtherm.hvac_mode == HVACMode.COOL
assert mock_send_event.call_count == 0
assert (
vtherm._auto_start_stop_algo.accumulated_error == 0 # target = current = 25
vtherm.auto_start_stop_manager._auto_start_stop_algo.accumulated_error
== 0 # target = current = 25
)
# 4. Set current temperature to 23 5 min later -> should turn off
@@ -764,7 +779,9 @@ async def test_auto_start_stop_fast_ac_vtherm(
assert vtherm.hvac_mode == HVACMode.OFF
# accumulated_error = target - current = 2 x 5 min / 2 capped to 2
assert vtherm._auto_start_stop_algo.accumulated_error == 2
assert (
vtherm.auto_start_stop_manager._auto_start_stop_algo.accumulated_error == 2
)
# a message should have been sent
assert mock_send_event.call_count >= 1
@@ -809,7 +826,9 @@ async def test_auto_start_stop_fast_ac_vtherm(
await hass.async_block_till_done()
# accumulated_error = 2/2 + target - current = -1 x 20 min / 2 capped to 2
assert vtherm._auto_start_stop_algo.accumulated_error == -2
assert (
vtherm.auto_start_stop_manager._auto_start_stop_algo.accumulated_error == -2
)
# VTherm should stay stopped
assert vtherm.hvac_mode == HVACMode.OFF
@@ -826,7 +845,9 @@ async def test_auto_start_stop_fast_ac_vtherm(
await hass.async_block_till_done()
# accumulated_error = 2/2 + target - current = -1 x 20 min / 2 capped to 2
assert vtherm._auto_start_stop_algo.accumulated_error == -2
assert (
vtherm.auto_start_stop_manager._auto_start_stop_algo.accumulated_error == -2
)
# VTherm should have been stopped
assert vtherm.hvac_mode == HVACMode.COOL
@@ -911,8 +932,8 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change(
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True,
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_FAST,
@@ -948,7 +969,10 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change(
assert vtherm._attr_extra_state_attributes["auto_start_stop_dtmin"] == 7
# 1. Vtherm auto-start/stop should be in MEDIUM mode
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_FAST
assert (
vtherm.auto_start_stop_manager.auto_start_stop_level
== AUTO_START_STOP_LEVEL_FAST
)
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
@@ -966,7 +990,7 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change(
# 3. Set current temperature to 21 5 min later to auto-stop
now = now + timedelta(minutes=5)
vtherm._auto_start_stop_algo._accumulated_error = 0
vtherm.auto_start_stop_manager._auto_start_stop_algo._accumulated_error = 0
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event:
@@ -977,7 +1001,9 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change(
# VTherm should have been stopped
assert vtherm.hvac_mode == HVACMode.OFF
assert vtherm._auto_start_stop_algo.accumulated_error == -2
assert (
vtherm.auto_start_stop_manager._auto_start_stop_algo.accumulated_error == -2
)
# a message should have been sent
assert mock_send_event.call_count >= 1
@@ -1032,7 +1058,9 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change(
await hass.async_block_till_done()
assert vtherm.target_temperature == 21
assert vtherm._auto_start_stop_algo.accumulated_error == 2
assert (
vtherm.auto_start_stop_manager._auto_start_stop_algo.accumulated_error == 2
)
# VTherm should have been restarted
assert vtherm.hvac_mode == HVACMode.HEAT
@@ -1117,8 +1145,8 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change_enable_false(
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True,
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_FAST,
@@ -1154,7 +1182,10 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change_enable_false(
assert vtherm._attr_extra_state_attributes["auto_start_stop_dtmin"] == 7
# 1. Vtherm auto-start/stop should be in FAST mode and enable should be on
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_FAST
assert (
vtherm.auto_start_stop_manager.auto_start_stop_level
== AUTO_START_STOP_LEVEL_FAST
)
enable_entity = search_entity(
hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN
)
@@ -1185,7 +1216,7 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change_enable_false(
# 3. Set current temperature to 21 5 min later to auto-stop
now = now + timedelta(minutes=5)
vtherm._auto_start_stop_algo._accumulated_error = 0
vtherm.auto_start_stop_manager._auto_start_stop_algo._accumulated_error = 0
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event:
@@ -1197,7 +1228,9 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change_enable_false(
assert vtherm.hvac_mode == HVACMode.HEAT
# Not calculated cause enable = false
assert vtherm._auto_start_stop_algo.accumulated_error == 0
assert (
vtherm.auto_start_stop_manager._auto_start_stop_algo.accumulated_error == 0
)
# a message should have been sent
assert mock_send_event.call_count == 0
@@ -1251,8 +1284,8 @@ async def test_auto_start_stop_fast_heat_window(
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True,
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_FAST,
@@ -1288,7 +1321,10 @@ async def test_auto_start_stop_fast_heat_window(
assert vtherm._attr_extra_state_attributes["auto_start_stop_dtmin"] == 7
# 1. Vtherm auto-start/stop should be in MEDIUM mode and an enable entity should exists
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_FAST
assert (
vtherm.auto_start_stop_manager.auto_start_stop_level
== AUTO_START_STOP_LEVEL_FAST
)
enable_entity = search_entity(
hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN
)
@@ -1299,7 +1335,7 @@ async def test_auto_start_stop_fast_heat_window(
now: datetime = datetime.now(tz=tz)
# 2. Set mode to Heat and preset to Comfort and close the window
send_window_change_event(vtherm, False, False, now, False)
await send_window_change_event(vtherm, False, False, now, False)
await send_presence_change_event(vtherm, True, False, now)
await send_temperature_change_event(vtherm, 18, now, True)
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
@@ -1310,12 +1346,12 @@ async def test_auto_start_stop_fast_heat_window(
# VTherm should be heating
assert vtherm.hvac_mode == HVACMode.HEAT
# VTherm window_state should be off
assert vtherm.window_state == STATE_OFF
assert vtherm.window_state == STATE_UNKNOWN # cause condition is not evaluated
# 3. Set current temperature to 21 5 min later -> should turn off VTherm
now = now + timedelta(minutes=5)
# reset accumulated error (only for testing)
vtherm._auto_start_stop_algo._accumulated_error = 0
vtherm.auto_start_stop_manager._auto_start_stop_algo._accumulated_error = 0
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event:
@@ -1426,8 +1462,8 @@ async def test_auto_start_stop_fast_heat_window_mixed(
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True,
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_FAST,
@@ -1463,7 +1499,10 @@ async def test_auto_start_stop_fast_heat_window_mixed(
assert vtherm._attr_extra_state_attributes["auto_start_stop_dtmin"] == 7
# 1. Vtherm auto-start/stop should be in MEDIUM mode and an enable entity should exists
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_FAST
assert (
vtherm.auto_start_stop_manager.auto_start_stop_level
== AUTO_START_STOP_LEVEL_FAST
)
enable_entity = search_entity(
hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN
)
@@ -1474,7 +1513,7 @@ async def test_auto_start_stop_fast_heat_window_mixed(
now: datetime = datetime.now(tz=tz)
# 2. Set mode to Heat and preset to Comfort and close the window
send_window_change_event(vtherm, False, False, now, False)
await send_window_change_event(vtherm, False, False, now, False)
await send_presence_change_event(vtherm, True, False, now)
await send_temperature_change_event(vtherm, 18, now, True)
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
@@ -1485,7 +1524,7 @@ async def test_auto_start_stop_fast_heat_window_mixed(
# VTherm should be heating
assert vtherm.hvac_mode == HVACMode.HEAT
# VTherm window_state should be off
assert vtherm.window_state == STATE_OFF
assert vtherm.window_state == STATE_UNKNOWN # cause try_condition is not evaluated
# 3. Open the window and wait for the delay
now = now + timedelta(minutes=2)
@@ -1513,7 +1552,7 @@ async def test_auto_start_stop_fast_heat_window_mixed(
# 4. Set current temperature to 21 5 min later -> should turn off VTherm
now = now + timedelta(minutes=5)
# reset accumulated error (only for testing)
vtherm._auto_start_stop_algo._accumulated_error = 0
vtherm.auto_start_stop_manager._auto_start_stop_algo._accumulated_error = 0
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event:
@@ -1605,8 +1644,8 @@ async def test_auto_start_stop_disable_vtherm_off(
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: False,
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_FAST,
@@ -1637,6 +1676,9 @@ async def test_auto_start_stop_disable_vtherm_off(
await set_all_climate_preset_temp(hass, vtherm, temps, "overclimate")
# Check correct initialization of auto_start_stop attributes
assert (
vtherm._attr_extra_state_attributes["is_auto_start_stop_configured"] is True
)
assert (
vtherm._attr_extra_state_attributes["auto_start_stop_level"]
== AUTO_START_STOP_LEVEL_FAST
@@ -1646,7 +1688,10 @@ async def test_auto_start_stop_disable_vtherm_off(
# 1. Vtherm auto-start/stop should be in FAST mode and enable should be on
vtherm._set_now(now)
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_FAST
assert (
vtherm.auto_start_stop_manager.auto_start_stop_level
== AUTO_START_STOP_LEVEL_FAST
)
enable_entity = search_entity(
hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN
)

View File

@@ -0,0 +1,120 @@
# pylint: disable=unused-argument, line-too-long, protected-access, too-many-lines
""" Test the Window management """
import logging
from unittest.mock import PropertyMock, MagicMock
from custom_components.versatile_thermostat.base_thermostat import BaseThermostat
from custom_components.versatile_thermostat.feature_auto_start_stop_manager import (
FeatureAutoStartStopManager,
)
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
logging.getLogger().setLevel(logging.DEBUG)
async def test_auto_start_stop_feature_manager_create(
hass: HomeAssistant,
):
"""Test the FeatureMotionManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
# 1. creation
auto_start_stop_manager = FeatureAutoStartStopManager(fake_vtherm, hass)
assert auto_start_stop_manager is not None
assert auto_start_stop_manager.is_configured is False
assert auto_start_stop_manager.is_auto_stopped is False
assert auto_start_stop_manager.auto_start_stop_enable is False
assert auto_start_stop_manager.name == "the name"
assert len(auto_start_stop_manager._active_listener) == 0
custom_attributes = {}
auto_start_stop_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["is_auto_start_stop_configured"] is False
# assert custom_attributes["auto_start_stop_enable"] is False
# assert custom_attributes["auto_start_stop_level"] == AUTO_START_STOP_LEVEL_NONE
# assert custom_attributes["auto_start_stop_dtmin"] is None
# assert custom_attributes["auto_start_stop_accumulated_error"] is None
# assert custom_attributes["auto_start_stop_accumulated_error_threshold"] is None
# assert custom_attributes["auto_start_stop_last_switch_date"] is None
@pytest.mark.parametrize(
"use_auto_start_stop_feature, level, is_configured",
[
# fmt: off
( True, AUTO_START_STOP_LEVEL_NONE, True),
( True, AUTO_START_STOP_LEVEL_SLOW, True),
( True, AUTO_START_STOP_LEVEL_MEDIUM, True),
( True, AUTO_START_STOP_LEVEL_FAST, True),
# Level is missing , will be set to None
( True, None, True),
( False, AUTO_START_STOP_LEVEL_NONE, False),
( False, AUTO_START_STOP_LEVEL_SLOW, False),
( False, AUTO_START_STOP_LEVEL_MEDIUM, False),
( False, AUTO_START_STOP_LEVEL_FAST, False),
# Level is missing , will be set to None
( False, None, False),
# fmt: on
],
)
async def test_auto_start_stop_feature_manager_post_init(
hass: HomeAssistant, use_auto_start_stop_feature, level, is_configured
):
"""Test the FeatureMotionManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
# 1. creation
auto_start_stop_manager = FeatureAutoStartStopManager(fake_vtherm, hass)
assert auto_start_stop_manager is not None
# 2. post_init
auto_start_stop_manager.post_init(
{
CONF_USE_AUTO_START_STOP_FEATURE: use_auto_start_stop_feature,
CONF_AUTO_START_STOP_LEVEL: level,
}
)
assert auto_start_stop_manager.is_configured is is_configured
assert (
auto_start_stop_manager.auto_start_stop_level == level
if level and is_configured
else AUTO_START_STOP_LEVEL_NONE
)
assert auto_start_stop_manager.auto_start_stop_enable is False
assert auto_start_stop_manager._auto_start_stop_algo is not None
custom_attributes = {}
auto_start_stop_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["is_auto_start_stop_configured"] is is_configured
if auto_start_stop_manager.is_configured:
assert custom_attributes["auto_start_stop_enable"] is False
assert (
custom_attributes["auto_start_stop_level"] == level
if level and is_configured
else AUTO_START_STOP_LEVEL_NONE
)
assert (
custom_attributes["auto_start_stop_dtmin"]
== auto_start_stop_manager._auto_start_stop_algo.dt_min
)
assert (
custom_attributes["auto_start_stop_accumulated_error"]
== auto_start_stop_manager._auto_start_stop_algo.accumulated_error
)
assert (
custom_attributes["auto_start_stop_accumulated_error_threshold"]
== auto_start_stop_manager._auto_start_stop_algo.accumulated_error_threshold
)
assert (
custom_attributes["auto_start_stop_last_switch_date"]
== auto_start_stop_manager._auto_start_stop_algo.last_switch_date
)

View File

@@ -57,8 +57,8 @@ async def test_security_binary_sensors(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
},
)
@@ -84,17 +84,17 @@ async def test_security_binary_sensors(
# Set temperature in the past
event_timestamp = now - timedelta(minutes=6)
# set temperature to 15 so that on_percent will be > security_min_on_percent (0.2)
# set temperature to 15 so that on_percent will be > safety_min_on_percent (0.2)
await send_temperature_change_event(entity, 15, event_timestamp)
assert entity.security_state is True
assert entity.safety_state is STATE_ON
# Simulate the event reception
await security_binary_sensor.async_my_climate_changed()
assert security_binary_sensor.state == STATE_ON
# set temperature now
await send_temperature_change_event(entity, 15, now)
assert entity.security_state is False
assert entity.safety_state is not STATE_ON
# Simulate the event reception
await security_binary_sensor.async_my_climate_changed()
assert security_binary_sensor.state == STATE_OFF
@@ -134,8 +134,8 @@ async def test_overpowering_binary_sensors(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_POWER_SENSOR: "sensor.mock_power_sensor",
CONF_MAX_POWER_SENSOR: "sensor.mock_power_max_sensor",
CONF_DEVICE_POWER: 100,
@@ -159,8 +159,8 @@ async def test_overpowering_binary_sensors(
await entity.async_set_preset_mode(PRESET_COMFORT)
await entity.async_set_hvac_mode(HVACMode.HEAT)
await send_temperature_change_event(entity, 15, now)
assert await entity.check_overpowering() is False
assert entity.overpowering_state is None
assert await entity.power_manager.check_overpowering() is False
assert entity.power_manager.overpowering_state is STATE_UNKNOWN
await overpowering_binary_sensor.async_my_climate_changed()
assert overpowering_binary_sensor.state is STATE_OFF
@@ -168,8 +168,8 @@ async def test_overpowering_binary_sensors(
await send_power_change_event(entity, 100, now)
await send_max_power_change_event(entity, 150, now)
assert await entity.check_overpowering() is True
assert entity.overpowering_state is True
assert await entity.power_manager.check_overpowering() is True
assert entity.power_manager.overpowering_state is STATE_ON
# Simulate the event reception
await overpowering_binary_sensor.async_my_climate_changed()
@@ -177,8 +177,8 @@ async def test_overpowering_binary_sensors(
# set max power to a low value
await send_max_power_change_event(entity, 201, now)
assert await entity.check_overpowering() is False
assert entity.overpowering_state is False
assert await entity.power_manager.check_overpowering() is False
assert entity.power_manager.overpowering_state is STATE_OFF
# Simulate the event reception
await overpowering_binary_sensor.async_my_climate_changed()
assert overpowering_binary_sensor.state == STATE_OFF
@@ -218,8 +218,8 @@ async def test_window_binary_sensors(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_SENSOR: "binary_sensor.mock_window_sensor",
CONF_WINDOW_DELAY: 0, # important to not been obliged to wait
},
@@ -241,7 +241,7 @@ async def test_window_binary_sensors(
await entity.async_set_preset_mode(PRESET_COMFORT)
await entity.async_set_hvac_mode(HVACMode.HEAT)
await send_temperature_change_event(entity, 15, now)
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNKNOWN
await window_binary_sensor.async_my_climate_changed()
assert window_binary_sensor.state is STATE_OFF
@@ -306,10 +306,12 @@ async def test_motion_binary_sensors(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_MOTION_SENSOR: "binary_sensor.mock_motion_sensor",
CONF_MOTION_DELAY: 0, # important to not been obliged to wait
CONF_MOTION_PRESET: PRESET_BOOST,
CONF_NO_MOTION_PRESET: PRESET_ECO,
},
)
@@ -329,7 +331,7 @@ async def test_motion_binary_sensors(
await entity.async_set_preset_mode(PRESET_COMFORT)
await entity.async_set_hvac_mode(HVACMode.HEAT)
await send_temperature_change_event(entity, 15, now)
assert entity.motion_state is None
assert entity.motion_state is STATE_UNKNOWN
await motion_binary_sensor.async_my_climate_changed()
assert motion_binary_sensor.state is STATE_OFF
@@ -397,8 +399,8 @@ async def test_presence_binary_sensors(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_PRESENCE_SENSOR: "binary_sensor.mock_presence_sensor",
},
)
@@ -419,7 +421,7 @@ async def test_presence_binary_sensors(
await entity.async_set_preset_mode(PRESET_COMFORT)
await entity.async_set_hvac_mode(HVACMode.HEAT)
await send_temperature_change_event(entity, 15, now)
assert entity.presence_state is None
assert entity.presence_state is STATE_UNKNOWN
await presence_binary_sensor.async_my_climate_changed()
assert presence_binary_sensor.state is STATE_OFF
@@ -480,8 +482,8 @@ async def test_binary_sensors_over_climate_minimal(
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
},
)

View File

@@ -37,7 +37,7 @@ async def test_bug_63(
skip_turn_on_off_heater,
skip_send_event,
):
"""Test that it should be possible to set the security_default_on_percent to 0"""
"""Test that it should be possible to set the safety_default_on_percent to 0"""
entry = MockConfigEntry(
domain=DOMAIN,
@@ -63,9 +63,9 @@ async def test_bug_63(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.0, # !! here
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.0, # !! here
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.0, # !! here
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.0, # !! here
CONF_DEVICE_POWER: 200,
},
)
@@ -75,8 +75,8 @@ async def test_bug_63(
)
assert entity
assert entity._security_min_on_percent == 0
assert entity._security_default_on_percent == 0
assert entity.safety_manager.safety_min_on_percent == 0
assert entity.safety_manager.safety_default_on_percent == 0
# Waiting for answer in https://github.com/jmcollin78/versatile_thermostat/issues/64
@@ -89,7 +89,7 @@ async def test_bug_64(
skip_turn_on_off_heater,
skip_send_event,
):
"""Test that it should be possible to set the security_default_on_percent to 0"""
"""Test that it should be possible to set the safety_default_on_percent to 0"""
entry = MockConfigEntry(
domain=DOMAIN,
@@ -115,9 +115,9 @@ async def test_bug_64(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1, # !! here
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.5,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1, # !! here
CONF_DEVICE_POWER: 200,
},
)
@@ -299,8 +299,8 @@ async def test_bug_407(hass: HomeAssistant, skip_hass_states_is_state):
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_POWER_SENSOR: "sensor.mock_power_sensor",
CONF_MAX_POWER_SENSOR: "sensor.mock_power_max_sensor",
CONF_DEVICE_POWER: 100,
@@ -334,7 +334,7 @@ async def test_bug_407(hass: HomeAssistant, skip_hass_states_is_state):
await entity.async_set_preset_mode(PRESET_COMFORT)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_COMFORT
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNKNOWN
assert entity.target_temperature == 18
# waits that the heater starts
await asyncio.sleep(0.1)
@@ -346,10 +346,10 @@ async def test_bug_407(hass: HomeAssistant, skip_hass_states_is_state):
# Send power mesurement (theheater is already in the power measurement)
await send_power_change_event(entity, 100, datetime.now())
# No overpowering yet
assert await entity.check_overpowering() is False
assert await entity.power_manager.check_overpowering() is False
# All configuration is complete and power is < power_max
assert entity.preset_mode is PRESET_COMFORT
assert entity.overpowering_state is False
assert entity.power_manager.overpowering_state is STATE_OFF
assert entity.is_device_active is True
# 2. An already active heater that switch preset will not switch to overpowering
@@ -365,10 +365,10 @@ async def test_bug_407(hass: HomeAssistant, skip_hass_states_is_state):
# waits that the heater starts
await asyncio.sleep(0.1)
assert await entity.check_overpowering() is False
assert await entity.power_manager.check_overpowering() is False
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is False
assert entity.power_manager.overpowering_state is STATE_OFF
assert entity.target_temperature == 19
assert mock_service_call.call_count >= 1
@@ -385,10 +385,10 @@ async def test_bug_407(hass: HomeAssistant, skip_hass_states_is_state):
# waits that the heater starts
await asyncio.sleep(0.1)
assert await entity.check_overpowering() is True
assert await entity.power_manager.check_overpowering() is True
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_POWER
assert entity.overpowering_state is True
assert entity.power_manager.overpowering_state is STATE_ON
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@@ -510,8 +510,8 @@ async def test_bug_465(hass: HomeAssistant, skip_hass_states_is_state):
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True,
},

View File

@@ -2,7 +2,7 @@
""" Test the central_configuration """
import asyncio
from datetime import datetime
from datetime import datetime, timedelta
from unittest.mock import patch, call
@@ -29,6 +29,8 @@ from custom_components.versatile_thermostat.binary_sensor import (
CentralBoilerBinarySensor,
)
from custom_components.versatile_thermostat.sensor import NbActiveDeviceForBoilerSensor
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
@@ -103,15 +105,15 @@ async def test_update_central_boiler_state_simple(
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_HEATER: switch1.entity_id,
CONF_UNDERLYING_LIST: [switch1.entity_id],
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_INVERSE_SWITCH: False,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
CONF_USE_MAIN_CENTRAL_CONFIG: True,
CONF_USE_TPI_CENTRAL_CONFIG: True,
CONF_USE_PRESETS_CENTRAL_CONFIG: True,
@@ -147,6 +149,13 @@ async def test_update_central_boiler_state_simple(
assert boiler_binary_sensor is not None
assert boiler_binary_sensor.state == STATE_OFF
nb_device_active_sensor: NbActiveDeviceForBoilerSensor = search_entity(
hass, "sensor.nb_device_active_for_boiler", "sensor"
)
assert nb_device_active_sensor is not None
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
# 1. start a heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -195,6 +204,9 @@ async def test_update_central_boiler_state_simple(
assert api.nb_active_device_for_boiler == 1
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 1
assert nb_device_active_sensor.active_device_ids == ["switch.switch1"]
# 2. stop a heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -235,6 +247,9 @@ async def test_update_central_boiler_state_simple(
assert api.nb_active_device_for_boiler == 0
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
entity.remove_thermostat()
@@ -272,18 +287,20 @@ async def test_update_central_boiler_state_multiple(
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_HEATER: switch1.entity_id,
CONF_HEATER_2: switch2.entity_id,
CONF_HEATER_3: switch3.entity_id,
CONF_HEATER_4: switch4.entity_id,
CONF_UNDERLYING_LIST: [
switch1.entity_id,
switch2.entity_id,
switch3.entity_id,
switch4.entity_id,
],
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_INVERSE_SWITCH: False,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
CONF_USE_MAIN_CENTRAL_CONFIG: True,
CONF_USE_TPI_CENTRAL_CONFIG: True,
CONF_USE_PRESETS_CENTRAL_CONFIG: True,
@@ -302,10 +319,18 @@ async def test_update_central_boiler_state_multiple(
assert entity.underlying_entities[1].entity_id == "switch.switch2"
assert entity.underlying_entities[2].entity_id == "switch.switch3"
assert entity.underlying_entities[3].entity_id == "switch.switch4"
assert entity.nb_device_actives == 0
assert entity.device_actives == []
assert api.nb_active_device_for_boiler_threshold == 1
assert api.nb_active_device_for_boiler == 0
nb_device_active_sensor: NbActiveDeviceForBoilerSensor = search_entity(
hass, "sensor.nb_device_active_for_boiler", "sensor"
)
assert nb_device_active_sensor is not None
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
# Force the VTherm to heat
await entity.async_set_hvac_mode(HVACMode.HEAT)
await entity.async_set_preset_mode(PRESET_BOOST)
@@ -338,7 +363,7 @@ async def test_update_central_boiler_state_multiple(
await asyncio.sleep(0.1)
assert entity.hvac_action == HVACAction.HEATING
assert entity.nb_device_actives == 1
assert entity.device_actives == ["switch.switch1"]
assert mock_service_call.call_count == 1
# No switch of the boiler
@@ -356,6 +381,9 @@ async def test_update_central_boiler_state_multiple(
assert api.nb_active_device_for_boiler == 1
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 1
assert nb_device_active_sensor.active_device_ids == ["switch.switch1"]
# 2. start a 2nd heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -368,7 +396,7 @@ async def test_update_central_boiler_state_multiple(
await asyncio.sleep(0.1)
assert entity.hvac_action == HVACAction.HEATING
assert entity.nb_device_actives == 2
assert entity.device_actives == ["switch.switch1", "switch.switch2"]
# Only the first heater is started by the algo
assert mock_service_call.call_count == 1
@@ -388,6 +416,12 @@ async def test_update_central_boiler_state_multiple(
assert api.nb_active_device_for_boiler == 2
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 2
assert nb_device_active_sensor.active_device_ids == [
"switch.switch1",
"switch.switch2",
]
# 3. start a 3rd heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -436,6 +470,13 @@ async def test_update_central_boiler_state_multiple(
assert api.nb_active_device_for_boiler == 3
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 3
assert nb_device_active_sensor.active_device_ids == [
"switch.switch1",
"switch.switch2",
"switch.switch3",
]
# 4. start a 4th heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -466,6 +507,14 @@ async def test_update_central_boiler_state_multiple(
assert api.nb_active_device_for_boiler == 4
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 4
assert nb_device_active_sensor.active_device_ids == [
"switch.switch1",
"switch.switch2",
"switch.switch3",
"switch.switch4",
]
# 5. stop a heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -484,6 +533,13 @@ async def test_update_central_boiler_state_multiple(
assert api.nb_active_device_for_boiler == 3
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 3
assert nb_device_active_sensor.active_device_ids == [
"switch.switch2",
"switch.switch3",
"switch.switch4",
]
# 6. stop a 2nd heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -524,6 +580,12 @@ async def test_update_central_boiler_state_multiple(
assert api.nb_active_device_for_boiler == 2
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 2
assert nb_device_active_sensor.active_device_ids == [
"switch.switch2",
"switch.switch3",
]
entity.remove_thermostat()
@@ -558,15 +620,15 @@ async def test_update_central_boiler_state_simple_valve(
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_VALVE: valve1.entity_id,
CONF_UNDERLYING_LIST: [valve1.entity_id],
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_INVERSE_SWITCH: False,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
CONF_USE_MAIN_CENTRAL_CONFIG: True,
CONF_USE_TPI_CENTRAL_CONFIG: True,
CONF_USE_PRESETS_CENTRAL_CONFIG: True,
@@ -594,7 +656,7 @@ async def test_update_central_boiler_state_simple_valve(
now: datetime = datetime.now(tz=tz)
assert entity.hvac_mode == HVACMode.HEAT
assert entity.nb_device_actives == 0
assert entity.device_actives == []
boiler_binary_sensor: CentralBoilerBinarySensor = search_entity(
hass, "binary_sensor.central_boiler", "binary_sensor"
@@ -602,6 +664,13 @@ async def test_update_central_boiler_state_simple_valve(
assert boiler_binary_sensor is not None
assert boiler_binary_sensor.state == STATE_OFF
nb_device_active_sensor: NbActiveDeviceForBoilerSensor = search_entity(
hass, "sensor.nb_device_active_for_boiler", "sensor"
)
assert nb_device_active_sensor is not None
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
# 1. start a valve
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -616,7 +685,7 @@ async def test_update_central_boiler_state_simple_valve(
await asyncio.sleep(0.1)
assert entity.hvac_action == HVACAction.HEATING
assert entity.nb_device_actives == 1
assert entity.device_actives == ["number.valve1"]
assert mock_service_call.call_count >= 1
mock_service_call.assert_has_calls(
@@ -644,6 +713,11 @@ async def test_update_central_boiler_state_simple_valve(
assert api.nb_active_device_for_boiler == 1
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 1
assert nb_device_active_sensor.active_device_ids == [
"number.valve1",
]
# 2. stop a heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -658,7 +732,7 @@ async def test_update_central_boiler_state_simple_valve(
await asyncio.sleep(0.1)
assert entity.hvac_action == HVACAction.IDLE
assert entity.nb_device_actives == 0
assert entity.device_actives == []
assert mock_service_call.call_count >= 1
mock_service_call.assert_has_calls(
@@ -687,6 +761,9 @@ async def test_update_central_boiler_state_simple_valve(
assert api.nb_active_device_for_boiler == 0
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
entity.remove_thermostat()
@@ -721,11 +798,11 @@ async def test_update_central_boiler_state_simple_climate(
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: climate1.entity_id,
CONF_UNDERLYING_LIST: [climate1.entity_id],
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
CONF_USE_MAIN_CENTRAL_CONFIG: True,
CONF_USE_PRESETS_CENTRAL_CONFIG: True,
CONF_USE_ADVANCED_CENTRAL_CONFIG: True,
@@ -748,6 +825,13 @@ async def test_update_central_boiler_state_simple_climate(
assert api.nb_active_device_for_boiler_threshold == 1
assert api.nb_active_device_for_boiler == 0
nb_device_active_sensor: NbActiveDeviceForBoilerSensor = search_entity(
hass, "sensor.nb_device_active_for_boiler", "sensor"
)
assert nb_device_active_sensor is not None
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
# Force the VTherm to heat
await entity.async_set_hvac_mode(HVACMode.HEAT)
await entity.async_set_preset_mode(PRESET_BOOST)
@@ -756,7 +840,7 @@ async def test_update_central_boiler_state_simple_climate(
now: datetime = datetime.now(tz=tz)
assert entity.hvac_mode == HVACMode.HEAT
assert entity.nb_device_actives == 0
assert entity.device_actives == []
boiler_binary_sensor: CentralBoilerBinarySensor = search_entity(
hass, "binary_sensor.central_boiler", "binary_sensor"
@@ -779,7 +863,7 @@ async def test_update_central_boiler_state_simple_climate(
await asyncio.sleep(0.5)
assert entity.hvac_action == HVACAction.HEATING
assert entity.nb_device_actives == 1
assert entity.device_actives == ["climate.climate1"]
assert mock_service_call.call_count >= 1
mock_service_call.assert_has_calls(
@@ -807,6 +891,11 @@ async def test_update_central_boiler_state_simple_climate(
assert api.nb_active_device_for_boiler == 1
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 1
assert nb_device_active_sensor.active_device_ids == [
"climate.climate1",
]
# 2. stop a climate
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -821,7 +910,7 @@ async def test_update_central_boiler_state_simple_climate(
await asyncio.sleep(0.5)
assert entity.hvac_action == HVACAction.IDLE
assert entity.nb_device_actives == 0
assert entity.device_actives == []
assert mock_service_call.call_count >= 1
mock_service_call.assert_has_calls(
@@ -850,6 +939,277 @@ async def test_update_central_boiler_state_simple_climate(
assert api.nb_active_device_for_boiler == 0
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
entity.remove_thermostat()
async def test_update_central_boiler_state_simple_climate_valve_regulation(
hass: HomeAssistant,
# skip_hass_states_is_state,
# skip_hass_states_get,
init_central_config_with_boiler_fixture,
):
"""Test that the central boiler state behavior with a climate with valve regulation"""
api = VersatileThermostatAPI.get_vtherm_api(hass)
climate1 = MockClimate(hass, "climate1", "theClimate1")
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverClimateMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 8,
CONF_TEMP_MAX: 18,
"frost_temp": 10,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 21,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_UNDERLYING_LIST: [climate1.entity_id],
CONF_OPENING_DEGREE_LIST: ["number.mock_opening_degree"],
CONF_CLOSING_DEGREE_LIST: [],
CONF_OFFSET_CALIBRATION_LIST: [],
CONF_AUTO_REGULATION_MODE: CONF_AUTO_REGULATION_VALVE,
CONF_AUTO_REGULATION_DTEMP: 0,
CONF_AUTO_REGULATION_PERIOD_MIN: 0,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.1,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_HIGH,
CONF_AUTO_REGULATION_USE_DEVICE_TEMP: False,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
CONF_USE_MAIN_CENTRAL_CONFIG: True,
CONF_USE_PRESETS_CENTRAL_CONFIG: True,
CONF_USE_ADVANCED_CENTRAL_CONFIG: True,
CONF_USED_BY_CENTRAL_BOILER: True,
},
)
open_degree_entity = MockNumber(hass, "mock_opening_degree", "Opening degree")
open_degree_entity.set_native_value(0)
# mock_get_state will be called for each OPENING/CLOSING/OFFSET_CALIBRATION list
mock_get_state_side_effect = SideEffects(
{
open_degree_entity.entity_id: State(
open_degree_entity.entity_id,
open_degree_entity.state,
{"min": 0, "max": 100},
),
"number.mock_closing_degree": State(
"number.mock_closing_degree", "0", {"min": 0, "max": 100}
),
"number.mock_offset_calibration": State(
"number.mock_offset_calibration", "0", {"min": -12, "max": 12}
),
},
State("unknown.entity_id", "unknown"),
)
with patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=climate1,
), patch(
"homeassistant.core.StateMachine.get",
side_effect=mock_get_state_side_effect.get_side_effects(),
):
entity: ThermostatOverClimate = await create_thermostat(
hass, entry, "climate.theoverclimatemockname"
)
assert entity
assert entity.name == "TheOverClimateMockName"
assert entity.is_over_climate
assert entity.underlying_entities[0].entity_id == "climate.climate1"
assert api.nb_active_device_for_boiler_threshold == 1
assert api.nb_active_device_for_boiler == 0
nb_device_active_sensor: NbActiveDeviceForBoilerSensor = search_entity(
hass, "sensor.nb_device_active_for_boiler", "sensor"
)
assert nb_device_active_sensor is not None
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
# Force the VTherm to heat
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
entity._set_now(now)
await send_temperature_change_event(entity, 30, now)
await send_ext_temperature_change_event(entity, 30, now)
await hass.async_block_till_done()
await entity.async_set_hvac_mode(HVACMode.HEAT)
await entity.async_set_preset_mode(PRESET_BOOST)
# the VTherm should not heat now
assert entity.hvac_mode == HVACMode.HEAT
assert entity.hvac_action == HVACAction.OFF
assert entity.activable_underlying_entities[0]._percent_open == 0
assert entity.device_actives == []
boiler_binary_sensor: CentralBoilerBinarySensor = search_entity(
hass, "binary_sensor.central_boiler", "binary_sensor"
)
assert boiler_binary_sensor is not None
assert boiler_binary_sensor.state == STATE_OFF
# 1. start a climate
open_degree_entity.set_native_value(100)
mock_get_state_side_effect = SideEffects(
{
open_degree_entity.entity_id: State(
open_degree_entity.entity_id,
open_degree_entity.state,
{"min": 0, "max": 100},
),
"number.mock_closing_degree": State(
"number.mock_closing_degree", "0", {"min": 0, "max": 100}
),
"number.mock_offset_calibration": State(
"number.mock_offset_calibration", "0", {"min": -12, "max": 12}
),
},
State("unknown.entity_id", "unknown"),
)
with patch(
"homeassistant.core.ServiceRegistry.async_call"
) as mock_service_call, patch(
"custom_components.versatile_thermostat.binary_sensor.send_vtherm_event"
) as mock_send_event, patch(
"homeassistant.core.StateMachine.get",
side_effect=mock_get_state_side_effect.get_side_effects(),
):
now = now + timedelta(minutes=1)
entity._set_now(now)
await send_temperature_change_event(entity, 10, now)
# we have to simulate the climate also else the test don't work
climate1.set_hvac_mode(HVACMode.HEAT)
climate1.set_hvac_action(HVACAction.HEATING)
climate1.async_write_ha_state()
open_degree_entity.set_native_value(100)
# Wait for state event propagation
await hass.async_block_till_done()
assert entity.hvac_action == HVACAction.HEATING
assert entity.device_actives == ["number.mock_opening_degree"]
assert api.nb_active_device_for_boiler == 1
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 1
assert nb_device_active_sensor.active_device_ids == [
"number.mock_opening_degree",
]
assert mock_service_call.call_count >= 1
mock_service_call.assert_has_calls(
[
call.service_call(
"switch",
"turn_on",
service_data={},
target={"entity_id": "switch.pompe_chaudiere"},
),
]
)
assert mock_send_event.call_count >= 1
mock_send_event.assert_has_calls(
[
call.send_vtherm_event(
hass=hass,
event_type=EventType.CENTRAL_BOILER_EVENT,
entity=api.central_boiler_entity,
data={"central_boiler": True},
)
]
)
# 2. stop a climate
open_degree_entity.set_native_value(0)
mock_get_state_side_effect = SideEffects(
{
open_degree_entity.entity_id: State(
open_degree_entity.entity_id,
open_degree_entity.state,
{"min": 0, "max": 100},
),
"number.mock_closing_degree": State(
"number.mock_closing_degree", "0", {"min": 0, "max": 100}
),
"number.mock_offset_calibration": State(
"number.mock_offset_calibration", "0", {"min": -12, "max": 12}
),
},
State("unknown.entity_id", "unknown"),
)
with patch(
"homeassistant.core.ServiceRegistry.async_call"
) as mock_service_call, patch(
"custom_components.versatile_thermostat.binary_sensor.send_vtherm_event"
) as mock_send_event, patch(
"homeassistant.core.StateMachine.get",
side_effect=mock_get_state_side_effect.get_side_effects(),
):
await send_temperature_change_event(entity, 25, now)
climate1.set_hvac_mode(HVACMode.HEAT)
climate1.set_hvac_action(HVACAction.IDLE)
climate1.async_write_ha_state()
open_degree_entity.set_native_value(0)
# Wait for state event propagation
await asyncio.sleep(0.5)
assert entity.hvac_action == HVACAction.OFF
assert entity.device_actives == []
assert mock_service_call.call_count >= 1
mock_service_call.assert_has_calls(
[
call(
"switch",
"turn_off",
service_data={},
target={"entity_id": "switch.pompe_chaudiere"},
)
]
)
assert mock_send_event.call_count >= 1
mock_send_event.assert_has_calls(
[
call.send_vtherm_event(
hass=hass,
event_type=EventType.CENTRAL_BOILER_EVENT,
entity=api.central_boiler_entity,
data={"central_boiler": False},
)
]
)
assert api.nb_active_device_for_boiler == 0
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
entity.remove_thermostat()
@@ -895,9 +1255,9 @@ async def test_bug_339(
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: climate1.entity_id,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
CONF_USE_MAIN_CENTRAL_CONFIG: True,
CONF_USE_PRESETS_CENTRAL_CONFIG: True,
CONF_USE_ADVANCED_CENTRAL_CONFIG: True,

View File

@@ -67,9 +67,9 @@ async def test_add_a_central_config(hass: HomeAssistant, skip_hass_states_is_sta
CONF_MAX_POWER_SENSOR: "sensor.mock_central_max_power_sensor",
CONF_PRESET_POWER: 14,
CONF_MINIMAL_ACTIVATION_DELAY: 11,
CONF_SECURITY_DELAY_MIN: 61,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.2,
CONF_SAFETY_DELAY_MIN: 61,
CONF_SAFETY_MIN_ON_PERCENT: 0.5,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.2,
CONF_USE_CENTRAL_BOILER_FEATURE: False,
},
)
@@ -135,9 +135,9 @@ async def test_minimal_over_switch_wo_central_config(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
# CONF_WINDOW_AUTO_OPEN_THRESHOLD: 0.1,
# CONF_WINDOW_AUTO_CLOSE_THRESHOLD: 0.1,
# CONF_WINDOW_AUTO_MAX_DURATION: 0, # Should be 0 for test
@@ -167,16 +167,16 @@ async def test_minimal_over_switch_wo_central_config(
assert entity.max_temp == 18
assert entity.target_temperature_step == 0.3
assert entity.preset_modes == ["none", "frost", "eco", "comfort", "boost"]
assert entity.is_window_auto_enabled is False
assert entity.window_manager.is_window_auto_configured is False
assert entity.nb_underlying_entities == 1
assert entity.underlying_entity_id(0) == "switch.mock_switch"
assert entity.proportional_algorithm is not None
assert entity.proportional_algorithm._tpi_coef_int == 0.3
assert entity.proportional_algorithm._tpi_coef_ext == 0.01
assert entity.proportional_algorithm._minimal_activation_delay == 30
assert entity._security_delay_min == 5
assert entity._security_min_on_percent == 0.3
assert entity._security_default_on_percent == 0.1
assert entity.safety_manager.safety_delay_min == 5
assert entity.safety_manager.safety_min_on_percent == 0.3
assert entity.safety_manager.safety_default_on_percent == 0.1
assert entity.is_inversed
entity.remove_thermostat()
@@ -220,9 +220,9 @@ async def test_full_over_switch_wo_central_config(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
CONF_WINDOW_SENSOR: "binary_sensor.mock_window_sensor",
CONF_WINDOW_DELAY: 30,
CONF_WINDOW_AUTO_OPEN_THRESHOLD: 3,
@@ -274,28 +274,42 @@ async def test_full_over_switch_wo_central_config(
assert entity.proportional_algorithm._tpi_coef_int == 0.3
assert entity.proportional_algorithm._tpi_coef_ext == 0.01
assert entity.proportional_algorithm._minimal_activation_delay == 30
assert entity._security_delay_min == 5
assert entity._security_min_on_percent == 0.3
assert entity._security_default_on_percent == 0.1
assert entity.safety_manager.safety_delay_min == 5
assert entity.safety_manager.safety_min_on_percent == 0.3
assert entity.safety_manager.safety_default_on_percent == 0.1
assert entity.is_inversed is False
assert entity.is_window_auto_enabled is False # we have an entity_id
assert entity._window_sensor_entity_id == "binary_sensor.mock_window_sensor"
assert entity._window_delay_sec == 30
assert entity._window_auto_close_threshold == 0.1
assert entity._window_auto_open_threshold == 3
assert entity._window_auto_max_duration == 5
assert (
entity.window_manager.is_window_auto_configured is False
) # we have an entity_id
assert (
entity.window_manager._window_sensor_entity_id
== "binary_sensor.mock_window_sensor"
)
assert entity.window_manager.window_delay_sec == 30
assert entity.window_manager.window_auto_close_threshold == 0.1
assert entity.window_manager.window_auto_open_threshold == 3
assert entity.window_manager.window_auto_max_duration == 5
assert entity._motion_sensor_entity_id == "binary_sensor.mock_motion_sensor"
assert entity._motion_delay_sec == 10
assert entity._motion_off_delay_sec == 29
assert entity._motion_preset == "comfort"
assert entity._no_motion_preset == "eco"
assert (
entity.motion_manager.motion_sensor_entity_id
== "binary_sensor.mock_motion_sensor"
)
assert entity.motion_manager.motion_delay_sec == 10
assert entity.motion_manager.motion_off_delay_sec == 29
assert entity.motion_manager.motion_preset == "comfort"
assert entity.motion_manager.no_motion_preset == "eco"
assert entity._power_sensor_entity_id == "sensor.mock_power_sensor"
assert entity._max_power_sensor_entity_id == "sensor.mock_max_power_sensor"
assert entity.power_manager.power_sensor_entity_id == "sensor.mock_power_sensor"
assert (
entity.power_manager.max_power_sensor_entity_id
== "sensor.mock_max_power_sensor"
)
assert entity._presence_sensor_entity_id == "binary_sensor.mock_presence_sensor"
assert (
entity._presence_manager.presence_sensor_entity_id
== "binary_sensor.mock_presence_sensor"
)
entity.remove_thermostat()
@@ -334,9 +348,9 @@ async def test_full_over_switch_with_central_config(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
CONF_WINDOW_SENSOR: "binary_sensor.mock_window_sensor",
CONF_WINDOW_DELAY: 30,
CONF_WINDOW_AUTO_OPEN_THRESHOLD: 3,
@@ -387,29 +401,41 @@ async def test_full_over_switch_with_central_config(
assert entity.proportional_algorithm._tpi_coef_int == 0.5
assert entity.proportional_algorithm._tpi_coef_ext == 0.02
assert entity.proportional_algorithm._minimal_activation_delay == 11
assert entity._security_delay_min == 61
assert entity._security_min_on_percent == 0.5
assert entity._security_default_on_percent == 0.2
assert entity.safety_manager.safety_delay_min == 61
assert entity.safety_manager.safety_min_on_percent == 0.5
assert entity.safety_manager.safety_default_on_percent == 0.2
assert entity.is_inversed is False
# We have an entity so window auto is not enabled
assert entity.is_window_auto_enabled is False
assert entity._window_sensor_entity_id == "binary_sensor.mock_window_sensor"
assert entity._window_delay_sec == 15
assert entity._window_auto_close_threshold == 1
assert entity._window_auto_open_threshold == 4
assert entity._window_auto_max_duration == 31
assert entity.window_manager.is_window_auto_configured is False
assert (
entity.window_manager._window_sensor_entity_id
== "binary_sensor.mock_window_sensor"
)
assert entity.window_manager.window_delay_sec == 15
assert entity.window_manager.window_auto_close_threshold == 1
assert entity.window_manager.window_auto_open_threshold == 4
assert entity.window_manager.window_auto_max_duration == 31
assert entity._motion_sensor_entity_id == "binary_sensor.mock_motion_sensor"
assert entity._motion_delay_sec == 31
assert entity._motion_off_delay_sec == 301
assert entity._motion_preset == "boost"
assert entity._no_motion_preset == "frost"
assert (
entity.motion_manager.motion_sensor_entity_id
== "binary_sensor.mock_motion_sensor"
)
assert entity.motion_manager.motion_delay_sec == 31
assert entity.motion_manager.motion_off_delay_sec == 301
assert entity.motion_manager.motion_preset == "boost"
assert entity.motion_manager.no_motion_preset == "frost"
assert entity._power_sensor_entity_id == "sensor.mock_power_sensor"
assert entity._max_power_sensor_entity_id == "sensor.mock_max_power_sensor"
assert entity.power_manager.power_sensor_entity_id == "sensor.mock_power_sensor"
assert (
entity.power_manager.max_power_sensor_entity_id
== "sensor.mock_max_power_sensor"
)
assert entity._presence_sensor_entity_id == "binary_sensor.mock_presence_sensor"
assert (
entity._presence_manager.presence_sensor_entity_id
== "binary_sensor.mock_presence_sensor"
)
entity.remove_thermostat()
@@ -469,7 +495,7 @@ async def test_migration_of_central_config(
central_config_entry = MockConfigEntry(
version=CONFIG_VERSION,
# An old minor version
minor_version=1,
minor_version=0,
domain=DOMAIN,
title="TheCentralConfigMockName",
unique_id="centralConfigUniqueId",
@@ -483,9 +509,9 @@ async def test_migration_of_central_config(
CONF_TPI_COEF_INT: 0.5,
CONF_TPI_COEF_EXT: 0.02,
CONF_MINIMAL_ACTIVATION_DELAY: 11,
CONF_SECURITY_DELAY_MIN: 61,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.2,
CONF_SAFETY_DELAY_MIN: 61,
CONF_SAFETY_MIN_ON_PERCENT: 0.5,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.2,
# The old central_boiler parameter
"add_central_boiler_control": True,
CONF_CENTRAL_BOILER_ACTIVATION_SRV: "switch.pompe_chaudiere/switch.turn_on",

View File

@@ -56,9 +56,9 @@ async def test_config_with_central_mode_true(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
},
)
@@ -103,9 +103,9 @@ async def test_config_with_central_mode_false(
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
},
)
@@ -153,9 +153,9 @@ async def test_config_with_central_mode_none(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
},
)
@@ -205,9 +205,9 @@ async def test_switch_change_central_mode_true(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
},
)
@@ -347,9 +347,9 @@ async def test_switch_ac_change_central_mode_true(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
CONF_AC_MODE: True,
},
)
@@ -482,9 +482,9 @@ async def test_climate_ac_change_central_mode_false(
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
},
)
@@ -624,9 +624,9 @@ async def test_climate_ac_only_change_central_mode_true(
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
},
)
@@ -778,9 +778,9 @@ async def test_switch_change_central_mode_true_with_window(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
CONF_WINDOW_SENSOR: "binary_sensor.window_sensor",
CONF_WINDOW_DELAY: 0, # To be not obliged to wait
CONF_MOTION_SENSOR: "input_boolean.motion_sensor",
@@ -816,7 +816,7 @@ async def test_switch_change_central_mode_true_with_window(
assert entity.hvac_mode == HVACMode.HEAT
assert entity.preset_mode == PRESET_ACTIVITY
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNKNOWN
# 2 Open the window
with patch(
@@ -935,9 +935,9 @@ async def test_switch_change_central_mode_true_with_cool_only_and_window(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
CONF_WINDOW_SENSOR: "binary_sensor.window_sensor",
CONF_WINDOW_DELAY: 0, # To be not obliged to wait
CONF_MOTION_SENSOR: "input_boolean.motion_sensor",
@@ -973,7 +973,7 @@ async def test_switch_change_central_mode_true_with_cool_only_and_window(
assert entity.hvac_mode == HVACMode.HEAT
assert entity.preset_mode == PRESET_ACTIVITY
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNKNOWN
# 2 Change central_mode to COOL_ONLY
with patch("homeassistant.core.ServiceRegistry.async_call"):

View File

@@ -470,9 +470,9 @@ async def test_user_config_flow_over_climate(
result["flow_id"],
user_input={
CONF_MINIMAL_ACTIVATION_DELAY: 10,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.4,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.4,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.3,
},
)
assert result["type"] == FlowResultType.MENU
@@ -496,9 +496,9 @@ async def test_user_config_flow_over_climate(
"data"
] == MOCK_TH_OVER_CLIMATE_USER_CONFIG | MOCK_TH_OVER_CLIMATE_MAIN_CONFIG | MOCK_TH_OVER_CLIMATE_CENTRAL_MAIN_CONFIG | MOCK_TH_OVER_CLIMATE_TYPE_CONFIG | {
CONF_MINIMAL_ACTIVATION_DELAY: 10,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.4,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.4,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.3,
} | MOCK_DEFAULT_FEATURE_CONFIG | {
CONF_USE_MAIN_CENTRAL_CONFIG: False,
CONF_USE_PRESETS_CENTRAL_CONFIG: False,
@@ -1077,9 +1077,9 @@ async def test_user_config_flow_over_climate_auto_start_stop(
result["flow_id"],
user_input={
CONF_MINIMAL_ACTIVATION_DELAY: 10,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.4,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.4,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.3,
},
)
assert result["type"] == FlowResultType.MENU
@@ -1104,9 +1104,9 @@ async def test_user_config_flow_over_climate_auto_start_stop(
"data"
] == MOCK_TH_OVER_CLIMATE_USER_CONFIG | MOCK_TH_OVER_CLIMATE_MAIN_CONFIG | MOCK_TH_OVER_CLIMATE_CENTRAL_MAIN_CONFIG | MOCK_TH_OVER_CLIMATE_TYPE_CONFIG | {
CONF_MINIMAL_ACTIVATION_DELAY: 10,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.4,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.4,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.3,
} | MOCK_DEFAULT_FEATURE_CONFIG | {
CONF_USE_MAIN_CENTRAL_CONFIG: False,
CONF_USE_TPI_CENTRAL_CONFIG: False,
@@ -1274,9 +1274,9 @@ async def test_user_config_flow_over_switch_bug_552_tpi(
result["flow_id"],
user_input={
CONF_MINIMAL_ACTIVATION_DELAY: 10,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.4,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.4,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.3,
},
)
@@ -1359,9 +1359,9 @@ async def test_user_config_flow_over_switch_bug_552_tpi(
CONF_TEMP_MAX: 30,
CONF_STEP_TEMPERATURE: 0.5,
CONF_MINIMAL_ACTIVATION_DELAY: 10,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.4,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.4,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.3,
CONF_USE_MAIN_CENTRAL_CONFIG: False,
CONF_USE_TPI_CENTRAL_CONFIG: False,
CONF_USE_PRESETS_CENTRAL_CONFIG: False,
@@ -1388,8 +1388,7 @@ async def test_user_config_flow_over_switch_bug_552_tpi(
# @pytest.mark.parametrize("expected_lingering_tasks", [True])
# @pytest.mark.parametrize("expected_lingering_timers", [True])
# @pytest.mark.skip
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_user_config_flow_over_climate_valve(
hass: HomeAssistant, skip_hass_states_get
): # pylint: disable=unused-argument
@@ -1581,6 +1580,7 @@ async def test_user_config_flow_over_climate_valve(
CONF_OFFSET_CALIBRATION_LIST: ["number.offset_calibration1"],
CONF_OPENING_DEGREE_LIST: ["number.opening_degree1"],
CONF_CLOSING_DEGREE_LIST: ["number.closing_degree1"],
CONF_MIN_OPENING_DEGREES: "10, 20,0",
},
)
assert result["type"] == FlowResultType.FORM
@@ -1619,6 +1619,7 @@ async def test_user_config_flow_over_climate_valve(
"number.opening_degree2",
],
CONF_CLOSING_DEGREE_LIST: [],
CONF_MIN_OPENING_DEGREES: "10, 20,0",
},
)
assert result["type"] == FlowResultType.MENU
@@ -1656,9 +1657,9 @@ async def test_user_config_flow_over_climate_valve(
result["flow_id"],
user_input={
CONF_MINIMAL_ACTIVATION_DELAY: 10,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.4,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.4,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.3,
},
)
assert result["type"] == FlowResultType.MENU
@@ -1684,9 +1685,9 @@ async def test_user_config_flow_over_climate_valve(
"data"
] == MOCK_TH_OVER_CLIMATE_USER_CONFIG | MOCK_TH_OVER_CLIMATE_MAIN_CONFIG | MOCK_TH_OVER_CLIMATE_CENTRAL_MAIN_CONFIG | MOCK_TH_OVER_CLIMATE_TYPE_CONFIG | {
CONF_MINIMAL_ACTIVATION_DELAY: 10,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.4,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.4,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.3,
} | MOCK_DEFAULT_FEATURE_CONFIG | {
CONF_USE_MAIN_CENTRAL_CONFIG: False,
CONF_USE_PRESETS_CENTRAL_CONFIG: False,
@@ -1715,6 +1716,7 @@ async def test_user_config_flow_over_climate_valve(
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.1,
CONF_MIN_OPENING_DEGREES: "10, 20,0",
}
assert result["result"]
assert result["result"].domain == DOMAIN

View File

@@ -42,8 +42,8 @@ async def test_inverted_switch(hass: HomeAssistant, skip_hass_states_is_state):
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_AUTO_OPEN_THRESHOLD: 0.1,
CONF_WINDOW_AUTO_CLOSE_THRESHOLD: 0.1,
CONF_WINDOW_AUTO_MAX_DURATION: 0, # Should be 0 for test

View File

@@ -25,6 +25,12 @@ async def test_last_seen_feature(hass: HomeAssistant, skip_hass_states_is_state)
"""
tz = get_tz(hass) # pylint: disable=invalid-name
temps = {
"frost": 7,
"eco": 17,
"comfort": 18,
"boost": 19,
}
entry = MockConfigEntry(
domain=DOMAIN,
@@ -39,22 +45,18 @@ async def test_last_seen_feature(hass: HomeAssistant, skip_hass_states_is_state)
"cycle_min": 5,
"temp_min": 15,
"temp_max": 30,
"frost_temp": 7,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 19,
"use_window_feature": False,
"use_motion_feature": False,
"use_power_feature": False,
"use_presence_feature": False,
"heater_entity_id": "switch.mock_switch",
CONF_UNDERLYING_LIST: ["switch.mock_switch"],
"proportional_function": "tpi",
"tpi_coef_int": 0.3,
"tpi_coef_ext": 0.01,
"minimal_activation_delay": 30,
"security_delay_min": 5, # 5 minutes
"security_min_on_percent": 0.2,
"security_default_on_percent": 0.1,
CONF_SAFETY_DELAY_MIN: 5, # 5 minutes
CONF_SAFETY_MIN_ON_PERCENT: 0.2,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1,
},
)
@@ -65,8 +67,10 @@ async def test_last_seen_feature(hass: HomeAssistant, skip_hass_states_is_state)
)
assert entity
assert entity._security_state is False
assert entity.preset_mode is not PRESET_SECURITY
await set_all_climate_preset_temp(hass, entity, temps, "theoverswitchmockname")
assert entity.safety_manager.is_safety_detected is False
assert entity.preset_mode is not PRESET_SAFETY
assert entity._last_ext_temperature_measure is not None
assert entity._last_temperature_measure is not None
assert (entity._last_temperature_measure.astimezone(tz) - now).total_seconds() < 1
@@ -84,6 +88,8 @@ async def test_last_seen_feature(hass: HomeAssistant, skip_hass_states_is_state)
await entity.async_set_hvac_mode(HVACMode.HEAT)
assert entity.hvac_mode == HVACMode.HEAT
last_change_time_from_vtherm = entity._last_change_time_from_vtherm
# 2. activate security feature when date is expired
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
@@ -92,15 +98,15 @@ async def test_last_seen_feature(hass: HomeAssistant, skip_hass_states_is_state)
) as mock_heater_on:
event_timestamp = now - timedelta(minutes=6)
# set temperature to 15 so that on_percent will be > security_min_on_percent (0.2)
# set temperature to 15 so that on_percent will be > safety_min_on_percent (0.2)
await send_temperature_change_event(entity, 15, event_timestamp)
assert entity.security_state is True
assert entity.preset_mode == PRESET_SECURITY
assert entity.safety_state is STATE_ON
assert entity.preset_mode == PRESET_SAFETY
assert mock_send_event.call_count == 3
mock_send_event.assert_has_calls(
[
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_SECURITY}),
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_SAFETY}),
call.send_event(
EventType.TEMPERATURE_EVENT,
{
@@ -128,9 +134,13 @@ async def test_last_seen_feature(hass: HomeAssistant, skip_hass_states_is_state)
assert mock_heater_on.call_count == 1
assert entity._last_change_time_from_vtherm == last_change_time_from_vtherm
# 3. change the last seen sensor
event_timestamp = now - timedelta(minutes=4)
await send_last_seen_temperature_change_event(entity, event_timestamp)
assert entity.security_state is False
assert entity.safety_state is not STATE_ON
assert entity.preset_mode is PRESET_COMFORT
assert entity._last_temperature_measure == event_timestamp
assert entity._last_change_time_from_vtherm == last_change_time_from_vtherm

View File

@@ -1,22 +1,288 @@
# pylint: disable=wildcard-import, unused-wildcard-import, protected-access, unused-argument, line-too-long, unused-variable
# pylint: disable=wildcard-import, unused-wildcard-import, protected-access, unused-argument, line-too-long, unused-variable, too-many-lines
""" Test the Window management """
from datetime import datetime, timedelta
import logging
from unittest.mock import patch
from unittest.mock import patch, call, AsyncMock, MagicMock, PropertyMock
from custom_components.versatile_thermostat.base_thermostat import BaseThermostat
from custom_components.versatile_thermostat.feature_motion_manager import (
FeatureMotionManager,
)
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
logging.getLogger().setLevel(logging.DEBUG)
@pytest.mark.parametrize(
"current_state, new_state, temp, nb_call, motion_state, is_motion_detected, preset_refresh, changed",
[
(STATE_OFF, STATE_ON, 21, 1, STATE_ON, True, PRESET_BOOST, True),
# motion is ON. So is_motion_detected is true and preset is BOOST
(STATE_OFF, STATE_ON, 21, 1, STATE_ON, True, PRESET_BOOST, True),
# current_state is ON and motion is OFF. So is_motion_detected is false and preset is ECO
(STATE_ON, STATE_OFF, 17, 1, STATE_OFF, False, PRESET_ECO, True),
],
)
async def test_motion_feature_manager_refresh(
hass: HomeAssistant,
current_state,
new_state, # new state of motion event
temp,
nb_call,
motion_state,
is_motion_detected,
preset_refresh,
changed,
):
"""Test the FeatureMotionManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
type(fake_vtherm).preset_mode = PropertyMock(return_value=PRESET_ACTIVITY)
# 1. creation
motion_manager = FeatureMotionManager(fake_vtherm, hass)
assert motion_manager is not None
assert motion_manager.is_configured is False
assert motion_manager.is_motion_detected is False
assert motion_manager.motion_state == STATE_UNAVAILABLE
assert motion_manager.name == "the name"
assert len(motion_manager._active_listener) == 0
custom_attributes = {}
motion_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["motion_sensor_entity_id"] is None
assert custom_attributes["motion_state"] == STATE_UNAVAILABLE
assert custom_attributes["is_motion_configured"] is False
assert custom_attributes["motion_preset"] is None
assert custom_attributes["no_motion_preset"] is None
assert custom_attributes["motion_delay_sec"] == 0
assert custom_attributes["motion_off_delay_sec"] == 0
# 2. post_init
motion_manager.post_init(
{
CONF_MOTION_SENSOR: "sensor.the_motion_sensor",
CONF_USE_MOTION_FEATURE: True,
CONF_MOTION_DELAY: 10,
CONF_MOTION_OFF_DELAY: 30,
CONF_MOTION_PRESET: PRESET_BOOST,
CONF_NO_MOTION_PRESET: PRESET_ECO,
}
)
assert motion_manager.is_configured is True
assert motion_manager.motion_state == STATE_UNKNOWN
assert motion_manager.is_motion_detected is False
custom_attributes = {}
motion_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["motion_sensor_entity_id"] == "sensor.the_motion_sensor"
assert custom_attributes["motion_state"] == STATE_UNKNOWN
assert custom_attributes["is_motion_configured"] is True
assert custom_attributes["motion_preset"] is PRESET_BOOST
assert custom_attributes["no_motion_preset"] is PRESET_ECO
assert custom_attributes["motion_delay_sec"] == 10
assert custom_attributes["motion_off_delay_sec"] == 30
# 3. start listening
motion_manager.start_listening()
assert motion_manager.is_configured is True
assert motion_manager.motion_state == STATE_UNKNOWN
assert motion_manager.is_motion_detected is False
assert len(motion_manager._active_listener) == 1
# 4. test refresh with the parametrized
# fmt:off
with patch("homeassistant.core.StateMachine.get", return_value=State("sensor.the_motion_sensor", new_state)) as mock_get_state:
# fmt:on
# Configurer les méthodes mockées
fake_vtherm.find_preset_temp.return_value = temp
fake_vtherm.change_target_temperature = AsyncMock()
fake_vtherm.async_control_heating = AsyncMock()
fake_vtherm.recalculate = MagicMock()
# force old state for the test
motion_manager._motion_state = current_state
ret = await motion_manager.refresh_state()
assert ret == changed
assert motion_manager.is_configured is True
# in the refresh there is no delay
assert motion_manager.motion_state == new_state
assert motion_manager.is_motion_detected is is_motion_detected
assert mock_get_state.call_count == 1
assert fake_vtherm.find_preset_temp.call_count == nb_call
if nb_call == 1:
fake_vtherm.find_preset_temp.assert_has_calls(
[
call.find_preset_temp(preset_refresh),
]
)
assert fake_vtherm.change_target_temperature.call_count == nb_call
fake_vtherm.change_target_temperature.assert_has_calls(
[
call.find_preset_temp(temp),
]
)
# We do not call control_heating at startup
assert fake_vtherm.recalculate.call_count == 0
assert fake_vtherm.async_control_heating.call_count == 0
fake_vtherm.reset_mock()
# 5. Check custom_attributes
custom_attributes = {}
motion_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["motion_sensor_entity_id"] == "sensor.the_motion_sensor"
assert custom_attributes["motion_state"] == new_state
assert custom_attributes["is_motion_configured"] is True
assert custom_attributes["motion_preset"] is PRESET_BOOST
assert custom_attributes["no_motion_preset"] is PRESET_ECO
assert custom_attributes["motion_delay_sec"] == 10
assert custom_attributes["motion_off_delay_sec"] == 30
motion_manager.stop_listening()
await hass.async_block_till_done()
@pytest.mark.parametrize(
"current_state, long_enough, new_state, temp, nb_call, motion_state, is_motion_detected, preset_event, changed",
[
(STATE_OFF, True, STATE_ON, 21, 1, STATE_ON, True, PRESET_BOOST, True),
# motion is ON but for not enough time but sensor is on at the end. So is_motion_detected is true and preset is BOOST
(STATE_OFF, False, STATE_ON, 21, 1, STATE_ON, True, PRESET_BOOST, True),
# motion is OFF for enough time. So is_motion_detected is false and preset is ECO
(STATE_ON, True, STATE_OFF, 17, 1, STATE_OFF, False, PRESET_ECO, True),
# motion is OFF for not enough time. So is_motion_detected is false and preset is ECO
(STATE_ON, False, STATE_OFF, 21, 1, STATE_ON, True, PRESET_BOOST, True),
],
)
async def test_motion_feature_manager_event(
hass: HomeAssistant,
current_state,
long_enough,
new_state, # new state of motion event
temp,
nb_call,
motion_state,
is_motion_detected,
preset_event,
changed,
):
"""Test the FeatureMotionManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
type(fake_vtherm).preset_mode = PropertyMock(return_value=PRESET_ACTIVITY)
# 1. iniitialization creation, post_init, start_listening
motion_manager = FeatureMotionManager(fake_vtherm, hass)
motion_manager.post_init(
{
CONF_MOTION_SENSOR: "sensor.the_motion_sensor",
CONF_USE_MOTION_FEATURE: True,
CONF_MOTION_DELAY: 10,
CONF_MOTION_OFF_DELAY: 30,
CONF_MOTION_PRESET: PRESET_BOOST,
CONF_NO_MOTION_PRESET: PRESET_ECO,
}
)
motion_manager.start_listening()
# 2. test _motion_sensor_changed with the parametrized
# fmt: off
with patch("homeassistant.helpers.condition.state", return_value=long_enough), \
patch("homeassistant.core.StateMachine.get", return_value=State("sensor.the_motion_sensor", new_state)):
# fmt: on
fake_vtherm.find_preset_temp.return_value = temp
fake_vtherm.change_target_temperature = AsyncMock()
fake_vtherm.async_control_heating = AsyncMock()
fake_vtherm.recalculate = MagicMock()
# force old state for the test
motion_manager._motion_state = current_state
delay = await motion_manager._motion_sensor_changed(
event=Event(
event_type=EVENT_STATE_CHANGED,
data={
"entity_id": "sensor.the_motion_sensor",
"new_state": State("sensor.the_motion_sensor", new_state),
"old_state": State("sensor.the_motion_sensor", STATE_UNAVAILABLE),
}))
assert delay is not None
await delay(None)
assert motion_manager.is_configured is True
assert motion_manager.motion_state == motion_state
assert motion_manager.is_motion_detected is is_motion_detected
assert fake_vtherm.find_preset_temp.call_count == nb_call
if nb_call == 1:
fake_vtherm.find_preset_temp.assert_has_calls(
[
call.find_preset_temp(preset_event),
]
)
assert fake_vtherm.change_target_temperature.call_count == nb_call
fake_vtherm.change_target_temperature.assert_has_calls(
[
call.find_preset_temp(temp),
]
)
assert fake_vtherm.recalculate.call_count == 1
assert fake_vtherm.async_control_heating.call_count == 1
fake_vtherm.async_control_heating.assert_has_calls([
call.async_control_heating(force=True)
])
fake_vtherm.reset_mock()
# 3. Check custom_attributes
custom_attributes = {}
motion_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["motion_sensor_entity_id"] == "sensor.the_motion_sensor"
assert custom_attributes["motion_state"] == motion_state
assert custom_attributes["is_motion_configured"] is True
assert custom_attributes["motion_preset"] is PRESET_BOOST
assert custom_attributes["no_motion_preset"] is PRESET_ECO
assert custom_attributes["motion_delay_sec"] == 10
assert custom_attributes["motion_off_delay_sec"] == 30
motion_manager.stop_listening()
await hass.async_block_till_done()
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_movement_management_time_not_enough(
async def test_motion_management_time_not_enough(
hass: HomeAssistant, skip_hass_states_is_state
):
"""Test the Presence management when time is not enough"""
temps = {
"frost": 10,
"eco": 17,
"comfort": 18,
"boost": 19,
"frost_away": 10,
"eco_away": 17,
"comfort_away": 18,
"boost_away": 19,
}
entry = MockConfigEntry(
domain=DOMAIN,
@@ -30,23 +296,17 @@ async def test_movement_management_time_not_enough(
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 19,
"eco_away_temp": 17,
"comfort_away_temp": 18,
"boost_away_temp": 19,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: True,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: True,
CONF_HEATER: "switch.mock_switch",
CONF_UNDERLYING_LIST: ["switch.mock_switch"],
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 10,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 10,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_MOTION_SENSOR: "binary_sensor.mock_motion_sensor",
CONF_MOTION_DELAY: 10, # important to not been obliged to wait
CONF_MOTION_OFF_DELAY: 30,
@@ -60,11 +320,12 @@ async def test_movement_management_time_not_enough(
hass, entry, "climate.theoverswitchmockname"
)
assert entity
await set_all_climate_preset_temp(hass, entity, temps, "theoverswitchmockname")
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
# start heating, in boost mode, when someone is present. We block the control_heating to avoid running a cycle
# 1. start heating, in boost mode, when someone is present. We block the control_heating to avoid running a cycle
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.async_control_heating"
):
@@ -75,17 +336,17 @@ async def test_movement_management_time_not_enough(
assert entity.preset_mode is PRESET_ACTIVITY
# because no motion is detected yet
assert entity.target_temperature == 18
assert entity.motion_state is None
assert entity.presence_state is None
assert entity.motion_state is STATE_UNKNOWN
assert entity.presence_state is STATE_UNKNOWN
event_timestamp = now - timedelta(minutes=5)
await send_temperature_change_event(entity, 18, event_timestamp)
await send_ext_temperature_change_event(entity, 10, event_timestamp)
await send_presence_change_event(entity, True, False, event_timestamp)
assert entity.presence_state == "on"
assert entity.presence_state == STATE_ON
# starts detecting motion with time not enough
# 2. starts detecting motion with time not enough
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
@@ -104,7 +365,9 @@ async def test_movement_management_time_not_enough(
),
):
event_timestamp = now - timedelta(minutes=4)
try_condition = await send_motion_change_event(entity, True, False, event_timestamp)
try_condition = await send_motion_change_event(
entity, True, False, event_timestamp
)
# Will return False -> we will stay on movement False
await try_condition(None)
@@ -137,7 +400,9 @@ async def test_movement_management_time_not_enough(
"homeassistant.helpers.condition.state", return_value=True
) as mock_condition:
event_timestamp = now - timedelta(minutes=3)
try_condition = await send_motion_change_event(entity, True, False, event_timestamp)
try_condition = await send_motion_change_event(
entity, True, False, event_timestamp
)
# Will return True -> we will switch to movement On
await try_condition(None)
@@ -168,7 +433,9 @@ async def test_movement_management_time_not_enough(
),
):
event_timestamp = now - timedelta(minutes=2)
try_condition = await send_motion_change_event(entity, False, True, event_timestamp)
try_condition = await send_motion_change_event(
entity, False, True, event_timestamp
)
# Will return False -> we will stay to movement On
await try_condition(None)
@@ -200,7 +467,9 @@ async def test_movement_management_time_not_enough(
"homeassistant.helpers.condition.state", return_value=True
) as mock_condition:
event_timestamp = now - timedelta(minutes=1)
try_condition = await send_motion_change_event(entity, False, True, event_timestamp)
try_condition = await send_motion_change_event(
entity, False, True, event_timestamp
)
# Will return True -> we will switch to movement Off
await try_condition(None)
@@ -221,7 +490,7 @@ async def test_movement_management_time_not_enough(
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_movement_management_time_enough_and_presence(
async def test_motion_management_time_enough_and_presence(
hass: HomeAssistant, skip_hass_states_is_state
):
"""Test the Motion management when time is not enough"""
@@ -253,8 +522,8 @@ async def test_movement_management_time_enough_and_presence(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_MOTION_SENSOR: "binary_sensor.mock_motion_sensor",
CONF_MOTION_DELAY: 0, # important to not been obliged to wait
CONF_MOTION_PRESET: "boost",
@@ -282,8 +551,8 @@ async def test_movement_management_time_enough_and_presence(
assert entity.preset_mode is PRESET_ACTIVITY
# because no motion is detected yet
assert entity.target_temperature == 18
assert entity.motion_state is None
assert entity.presence_state is None
assert entity.motion_state is STATE_UNKNOWN
assert entity.presence_state is STATE_UNKNOWN
event_timestamp = now - timedelta(minutes=4)
await send_temperature_change_event(entity, 18, event_timestamp)
@@ -312,9 +581,8 @@ async def test_movement_management_time_enough_and_presence(
assert entity.preset_mode is PRESET_ACTIVITY
# because motion is detected yet -> switch to Boost mode
assert entity.target_temperature == 19
assert entity.motion_state == "on"
assert entity.presence_state == "on"
assert entity.motion_state == STATE_ON
assert entity.presence_state == STATE_ON
assert mock_send_event.call_count == 0
# Change is confirmed. Heater should be started
assert mock_heater_on.call_count == 1
@@ -341,8 +609,8 @@ async def test_movement_management_time_enough_and_presence(
assert entity.preset_mode is PRESET_ACTIVITY
# because no motion is detected yet
assert entity.target_temperature == 18
assert entity.motion_state == "off"
assert entity.presence_state == "on"
assert entity.motion_state == STATE_OFF
assert entity.presence_state == STATE_ON
assert mock_send_event.call_count == 0
assert mock_heater_on.call_count == 0
@@ -353,7 +621,7 @@ async def test_movement_management_time_enough_and_presence(
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_movement_management_time_enoughand_not_presence(
async def test_motion_management_time_enough_and_not_presence(
hass: HomeAssistant, skip_hass_states_is_state
):
"""Test the Presence management when time is not enough"""
@@ -385,8 +653,8 @@ async def test_movement_management_time_enoughand_not_presence(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_MOTION_SENSOR: "binary_sensor.mock_motion_sensor",
CONF_MOTION_DELAY: 0, # important to not been obliged to wait
CONF_MOTION_PRESET: "boost",
@@ -414,15 +682,15 @@ async def test_movement_management_time_enoughand_not_presence(
assert entity.preset_mode is PRESET_ACTIVITY
# because no motion is detected yet and presence is unknown
assert entity.target_temperature == 18
assert entity.motion_state is None
assert entity.presence_state is None
assert entity.motion_state is STATE_UNKNOWN
assert entity.presence_state is STATE_UNKNOWN
event_timestamp = now - timedelta(minutes=4)
await send_temperature_change_event(entity, 18, event_timestamp)
await send_ext_temperature_change_event(entity, 10, event_timestamp)
await send_presence_change_event(entity, False, True, event_timestamp)
assert entity.presence_state == "off"
assert entity.presence_state == STATE_OFF
# starts detecting motion
with patch(
@@ -444,8 +712,8 @@ async def test_movement_management_time_enoughand_not_presence(
assert entity.preset_mode is PRESET_ACTIVITY
# because motion is detected yet -> switch to Boost away mode
assert entity.target_temperature == 19.1
assert entity.motion_state == "on"
assert entity.presence_state == "off"
assert entity.motion_state == STATE_ON
assert entity.presence_state == STATE_OFF
assert mock_send_event.call_count == 0
# Change is confirmed. Heater should be started
@@ -473,9 +741,8 @@ async def test_movement_management_time_enoughand_not_presence(
assert entity.preset_mode is PRESET_ACTIVITY
# because no motion is detected yet
assert entity.target_temperature == 18.1
assert entity.motion_state == "off"
assert entity.presence_state == "off"
assert entity.motion_state == STATE_OFF
assert entity.presence_state == STATE_OFF
assert mock_send_event.call_count == 0
# 18.1 starts heating with a low on_percent
assert mock_heater_on.call_count == 1
@@ -486,7 +753,7 @@ async def test_movement_management_time_enoughand_not_presence(
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_movement_management_with_stop_during_condition(
async def test_motion_management_with_stop_during_condition(
hass: HomeAssistant, skip_hass_states_is_state
):
"""Test the Motion management when the movement sensor switch to off and then to on during the test condition"""
@@ -518,8 +785,8 @@ async def test_movement_management_with_stop_during_condition(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_MOTION_SENSOR: "binary_sensor.mock_motion_sensor",
CONF_MOTION_DELAY: 10,
CONF_MOTION_OFF_DELAY: 30,
@@ -548,15 +815,15 @@ async def test_movement_management_with_stop_during_condition(
assert entity.preset_mode is PRESET_ACTIVITY
# because no motion is detected yet
assert entity.target_temperature == 18
assert entity.motion_state is None
assert entity.presence_state is None
assert entity.motion_state is STATE_UNKNOWN
assert entity.presence_state is STATE_UNKNOWN
event_timestamp = now - timedelta(minutes=6)
await send_temperature_change_event(entity, 18, event_timestamp)
await send_ext_temperature_change_event(entity, 10, event_timestamp)
await send_presence_change_event(entity, False, True, event_timestamp)
assert entity.presence_state == "off"
assert entity.presence_state == STATE_OFF
# starts detecting motion
with patch(
@@ -582,9 +849,8 @@ async def test_movement_management_with_stop_during_condition(
assert entity.preset_mode is PRESET_ACTIVITY
# because motion is detected yet -> switch to Boost mode
assert entity.target_temperature == 18
assert entity.motion_state is None
assert entity.presence_state == "off"
assert entity.motion_state is STATE_UNKNOWN
assert entity.presence_state == STATE_OFF
# Send a stop detection
event_timestamp = now - timedelta(minutes=4)
try_condition = await send_motion_change_event(
@@ -595,8 +861,8 @@ async def test_movement_management_with_stop_during_condition(
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_ACTIVITY
assert entity.target_temperature == 18
assert entity.motion_state is None
assert entity.presence_state == "off"
assert entity.motion_state is STATE_UNKNOWN
assert entity.presence_state == STATE_OFF
# Resend a start detection
event_timestamp = now - timedelta(minutes=3)
@@ -611,19 +877,19 @@ async def test_movement_management_with_stop_during_condition(
assert entity.preset_mode is PRESET_ACTIVITY
# still no motion detected
assert entity.target_temperature == 18
assert entity.motion_state is None
assert entity.presence_state == "off"
assert entity.motion_state is STATE_UNKNOWN
assert entity.presence_state == STATE_OFF
await try_condition1(None)
# We should have switch this time
assert entity.target_temperature == 19 # Boost
assert entity.motion_state == "on" # switch to movement on
assert entity.presence_state == "off" # Non change
assert entity.motion_state == STATE_ON # switch to movement on
assert entity.presence_state == STATE_OFF # Non change
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_movement_management_with_stop_during_condition_last_state_on(
async def test_motion_management_with_stop_during_condition_last_state_on(
hass: HomeAssistant, skip_hass_states_is_state
):
"""Test the Motion management when the movement sensor switch to off and then to on during the test condition"""
@@ -655,8 +921,8 @@ async def test_movement_management_with_stop_during_condition_last_state_on(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_MOTION_SENSOR: "binary_sensor.mock_motion_sensor",
CONF_MOTION_DELAY: 10,
CONF_MOTION_OFF_DELAY: 30,
@@ -684,7 +950,7 @@ async def test_movement_management_with_stop_during_condition_last_state_on(
assert entity.preset_mode is PRESET_ACTIVITY
# because no motion is detected yet
assert entity.target_temperature == 18
assert entity.motion_state is None
assert entity.motion_state is STATE_UNKNOWN
event_timestamp = now - timedelta(minutes=6)
await send_temperature_change_event(entity, 18, event_timestamp)

View File

@@ -45,8 +45,8 @@ async def test_one_switch_cycle(
CONF_USE_PRESENCE_FEATURE: False,
CONF_HEATER: "switch.mock_switch1",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
@@ -69,7 +69,7 @@ async def test_one_switch_cycle(
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 19
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNAVAILABLE
event_timestamp = now - timedelta(minutes=4)
await send_temperature_change_event(entity, 15, event_timestamp)
@@ -262,8 +262,8 @@ async def test_multiple_switchs(
CONF_HEATER_4: "switch.mock_switch4",
CONF_HEATER_KEEP_ALIVE: 0,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
@@ -289,7 +289,7 @@ async def test_multiple_switchs(
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 19
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNAVAILABLE
event_timestamp = now - timedelta(minutes=4)
await send_temperature_change_event(entity, 15, event_timestamp)
@@ -402,8 +402,8 @@ async def test_multiple_climates(
CONF_CLIMATE_3: "switch.mock_climate3",
CONF_CLIMATE_4: "switch.mock_climate4",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
},
)
@@ -426,7 +426,7 @@ async def test_multiple_climates(
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 19
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNAVAILABLE
event_timestamp = now - timedelta(minutes=4)
await send_temperature_change_event(entity, 15, event_timestamp)
@@ -451,7 +451,7 @@ async def test_multiple_climates(
assert entity.hvac_mode is HVACMode.OFF
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 19
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNAVAILABLE
event_timestamp = now - timedelta(minutes=4)
await send_temperature_change_event(entity, 15, event_timestamp)
@@ -503,8 +503,8 @@ async def test_multiple_climates_underlying_changes(
CONF_CLIMATE_3: "switch.mock_climate3",
CONF_CLIMATE_4: "switch.mock_climate4",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
},
)
@@ -527,7 +527,7 @@ async def test_multiple_climates_underlying_changes(
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 19
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNAVAILABLE
event_timestamp = now - timedelta(minutes=4)
await send_temperature_change_event(entity, 15, event_timestamp)
@@ -648,8 +648,8 @@ async def test_multiple_climates_underlying_changes_not_aligned(
CONF_CLIMATE_3: "switch.mock_climate3",
CONF_CLIMATE_4: "switch.mock_climate4",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
},
)
@@ -672,7 +672,7 @@ async def test_multiple_climates_underlying_changes_not_aligned(
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 19
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNAVAILABLE
event_timestamp = now - timedelta(minutes=4)
await send_temperature_change_event(entity, 15, event_timestamp)
@@ -750,8 +750,8 @@ async def test_multiple_switch_power_management(
CONF_HEATER_4: "switch.mock_switch4",
CONF_HEATER_KEEP_ALIVE: 0,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
@@ -776,17 +776,17 @@ async def test_multiple_switch_power_management(
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNKNOWN
assert entity.target_temperature == 19
# 1. Send power mesurement
await send_power_change_event(entity, 50, datetime.now())
# Send power max mesurement
await send_max_power_change_event(entity, 300, datetime.now())
assert await entity.check_overpowering() is False
assert await entity.power_manager.check_overpowering() is False
# All configuration is complete and power is < power_max
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is False
assert entity.power_manager.overpowering_state is STATE_OFF
# 2. Send power max mesurement too low and HVACMode is on
with patch(
@@ -798,10 +798,10 @@ async def test_multiple_switch_power_management(
) as mock_heater_off:
# 100 of the device / 4 -> 25, current power 50 so max is 75
await send_max_power_change_event(entity, 74, datetime.now())
assert await entity.check_overpowering() is True
assert await entity.power_manager.check_overpowering() is True
# All configuration is complete and power is > power_max we switch to POWER preset
assert entity.preset_mode is PRESET_POWER
assert entity.overpowering_state is True
assert entity.power_manager.overpowering_state is STATE_ON
assert entity.target_temperature == 12
assert mock_send_event.call_count == 2
@@ -814,7 +814,7 @@ async def test_multiple_switch_power_management(
"type": "start",
"current_power": 50,
"device_power": 100,
"current_power_max": 74,
"current_max_power": 74,
"current_power_consumption": 25.0,
},
),
@@ -831,7 +831,7 @@ async def test_multiple_switch_power_management(
await entity.async_set_preset_mode(PRESET_ECO)
assert entity.preset_mode is PRESET_ECO
# No change
assert entity.overpowering_state is True
assert entity.power_manager.overpowering_state is STATE_ON
# 4. Send hugh power max mesurement to release overpowering
with patch(
@@ -843,10 +843,10 @@ async def test_multiple_switch_power_management(
) as mock_heater_off:
# 100 of the device / 4 -> 25, current power 50 so max is 75. With 150 no overheating
await send_max_power_change_event(entity, 150, datetime.now())
assert await entity.check_overpowering() is False
assert await entity.power_manager.check_overpowering() is False
# All configuration is complete and power is > power_max we switch to POWER preset
assert entity.preset_mode is PRESET_ECO
assert entity.overpowering_state is False
assert entity.power_manager.overpowering_state is STATE_OFF
assert entity.target_temperature == 17
assert (

View File

@@ -62,8 +62,8 @@ async def test_bug_56(
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
},
)
@@ -151,7 +151,7 @@ async def test_bug_82(
PRESET_BOOST,
]
assert entity.preset_mode is PRESET_NONE
assert entity._security_state is False
assert entity.safety_manager.is_safety_detected is False
# should have been called with EventType.PRESET_EVENT and EventType.HVAC_MODE_EVENT
assert mock_send_event.call_count == 2
@@ -191,10 +191,10 @@ async def test_bug_82(
):
event_timestamp = now - timedelta(minutes=6)
# set temperature to 15 so that on_percent will be > security_min_on_percent (0.2)
# set temperature to 15 so that on_percent will be > safety_min_on_percent (0.2)
await send_temperature_change_event(entity, 15, event_timestamp)
# Should stay False
assert entity.security_state is False
assert entity.safety_state is not STATE_ON
assert entity.preset_mode == "none"
assert entity._saved_preset_mode == "none"
@@ -323,7 +323,7 @@ async def test_underlying_change_follow(
assert entity.target_temperature == entity.min_temp + 1
assert entity.preset_mode is PRESET_NONE
# 4. Change the target temp with < 1 value. The value should not be taken
# 4. Change the target temp with < 0.1 (step) value. The value should not be taken
# Wait 11 sec
event_timestamp = now + timedelta(seconds=11)
await send_climate_change_event_with_temperature(
@@ -333,7 +333,7 @@ async def test_underlying_change_follow(
HVACAction.OFF,
HVACAction.OFF,
event_timestamp,
entity.min_temp + 1.5,
entity.min_temp + 1.09,
True,
"climate.mock_climate", # the underlying climate entity id
)
@@ -641,8 +641,8 @@ async def test_bug_524(hass: HomeAssistant, skip_hass_states_is_state):
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True,
},
@@ -904,8 +904,8 @@ async def test_manual_hvac_off_should_take_the_lead_over_window(
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True,
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_FAST,
@@ -938,7 +938,10 @@ async def test_manual_hvac_off_should_take_the_lead_over_window(
== AUTO_START_STOP_LEVEL_FAST
)
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_FAST
assert (
vtherm.auto_start_stop_manager.auto_start_stop_level
== AUTO_START_STOP_LEVEL_FAST
)
enable_entity = search_entity(
hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN
)
@@ -949,7 +952,7 @@ async def test_manual_hvac_off_should_take_the_lead_over_window(
now: datetime = datetime.now(tz=tz)
# 1. Set mode to Heat and preset to Comfort and close the window
send_window_change_event(vtherm, False, False, now, False)
await send_window_change_event(vtherm, False, False, now, False)
await send_presence_change_event(vtherm, True, False, now)
await send_temperature_change_event(vtherm, 18, now, True)
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
@@ -960,7 +963,7 @@ async def test_manual_hvac_off_should_take_the_lead_over_window(
# VTherm should be heating
assert vtherm.hvac_mode == HVACMode.HEAT
# VTherm window_state should be off
assert vtherm.window_state == STATE_OFF
assert vtherm.window_state == STATE_UNKNOWN # Cause try_condition is not called
# 2. Open the window and wait for the delay
now = now + timedelta(minutes=2)
@@ -1078,8 +1081,8 @@ async def test_manual_hvac_off_should_take_the_lead_over_auto_start_stop(
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True,
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_FAST,
@@ -1112,7 +1115,10 @@ async def test_manual_hvac_off_should_take_the_lead_over_auto_start_stop(
== AUTO_START_STOP_LEVEL_FAST
)
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_FAST
assert (
vtherm.auto_start_stop_manager.auto_start_stop_level
== AUTO_START_STOP_LEVEL_FAST
)
enable_entity = search_entity(
hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN
)
@@ -1123,7 +1129,7 @@ async def test_manual_hvac_off_should_take_the_lead_over_auto_start_stop(
now: datetime = datetime.now(tz=tz)
# 1. Set mode to Heat and preset to Comfort
send_window_change_event(vtherm, False, False, now, False)
await send_window_change_event(vtherm, False, False, now, False)
await send_presence_change_event(vtherm, True, False, now)
await send_temperature_change_event(vtherm, 18, now, True)
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
@@ -1138,7 +1144,7 @@ async def test_manual_hvac_off_should_take_the_lead_over_auto_start_stop(
now = now + timedelta(minutes=5)
vtherm._set_now(now)
# reset accumulated error (only for testing)
vtherm._auto_start_stop_algo._accumulated_error = 0
vtherm.auto_start_stop_manager._auto_start_stop_algo._accumulated_error = 0
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event:

View File

@@ -18,7 +18,7 @@ from .const import *
logging.getLogger().setLevel(logging.DEBUG)
# @pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
# this test fails if run in // with the next because the underlying_valve_regulation is mixed. Don't know why
# @pytest.mark.skip
@@ -111,10 +111,10 @@ async def test_over_climate_valve_mono(hass: HomeAssistant, skip_hass_states_get
PRESET_BOOST,
]
assert vtherm.preset_mode is PRESET_NONE
assert vtherm._security_state is False
assert vtherm._window_state is None
assert vtherm._motion_state is None
assert vtherm._presence_state is None
assert vtherm.safety_manager.is_safety_detected is False
assert vtherm.window_state is STATE_UNAVAILABLE
assert vtherm.motion_state is STATE_UNAVAILABLE
assert vtherm.presence_state is STATE_UNAVAILABLE
assert vtherm.is_device_active is False
assert vtherm.valve_open_percent == 0
@@ -138,13 +138,13 @@ async def test_over_climate_valve_mono(hass: HomeAssistant, skip_hass_states_get
assert mock_service_call.call_count == 3
mock_service_call.assert_has_calls(
[
call(domain='number', service='set_value', service_data={'value': 0}, target={'entity_id': 'number.mock_opening_degree'}),
call(domain='number', service='set_value', service_data={'value': 100}, target={'entity_id': 'number.mock_closing_degree'}),
call("climate","set_temperature",{
"entity_id": "climate.mock_climate",
"temperature": 15, # temp-min
},
),
call(domain='number', service='set_value', service_data={'value': 0}, target={'entity_id': 'number.mock_opening_degree'}),
call(domain='number', service='set_value', service_data={'value': 100}, target={'entity_id': 'number.mock_closing_degree'}),
# we have no current_temperature yet
# call(domain='number', service='set_value', service_data={'value': 12}, target={'entity_id': 'number.mock_offset_calibration'}),
]
@@ -300,6 +300,7 @@ async def test_over_climate_valve_mono(hass: HomeAssistant, skip_hass_states_get
await hass.async_block_till_done()
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_over_climate_valve_multi_presence(
hass: HomeAssistant, skip_hass_states_get
):
@@ -482,3 +483,186 @@ async def test_over_climate_valve_multi_presence(
)
assert vtherm.nb_device_actives == 0
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_over_climate_valve_multi_min_opening_degrees(
hass: HomeAssistant, skip_hass_states_get
):
"""Test the normal full start of a thermostat in thermostat_over_climate type
with valve_regulation and min_opening_degreess set"""
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverClimateMockName",
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_DEVICE_POWER: 1,
CONF_USE_MAIN_CENTRAL_CONFIG: False,
CONF_USE_CENTRAL_MODE: False,
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
CONF_STEP_TEMPERATURE: 0.1,
CONF_UNDERLYING_LIST: ["climate.mock_climate1", "climate.mock_climate2"],
CONF_AC_MODE: False,
CONF_AUTO_REGULATION_MODE: CONF_AUTO_REGULATION_VALVE,
CONF_AUTO_REGULATION_DTEMP: 0.01,
CONF_AUTO_REGULATION_PERIOD_MIN: 0,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_HIGH,
CONF_AUTO_REGULATION_USE_DEVICE_TEMP: False,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.1,
CONF_OPENING_DEGREE_LIST: [
"number.mock_opening_degree1",
"number.mock_opening_degree2",
],
CONF_CLOSING_DEGREE_LIST: [
"number.mock_closing_degree1",
"number.mock_closing_degree2",
],
CONF_OFFSET_CALIBRATION_LIST: [
"number.mock_offset_calibration1",
"number.mock_offset_calibration2",
],
CONF_USE_PRESENCE_FEATURE: False,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_MIN_OPENING_DEGREES: "60,70",
}
| MOCK_DEFAULT_CENTRAL_CONFIG
| MOCK_ADVANCED_CONFIG,
)
fake_underlying_climate1 = MockClimate(
hass, "mockUniqueId1", "MockClimateName1", {}
)
fake_underlying_climate2 = MockClimate(
hass, "mockUniqueId2", "MockClimateName2", {}
)
# mock_get_state will be called for each OPENING/CLOSING/OFFSET_CALIBRATION list
mock_get_state_side_effect = SideEffects(
{
# Valve 1 is open
"number.mock_opening_degree1": State(
"number.mock_opening_degree1", "10", {"min": 0, "max": 100}
),
"number.mock_closing_degree1": State(
"number.mock_closing_degree1", "90", {"min": 0, "max": 100}
),
"number.mock_offset_calibration1": State(
"number.mock_offset_calibration1", "0", {"min": -12, "max": 12}
),
# Valve 2 is closed
"number.mock_opening_degree2": State(
"number.mock_opening_degree2", "0", {"min": 0, "max": 100}
),
"number.mock_closing_degree2": State(
"number.mock_closing_degree2", "100", {"min": 0, "max": 100}
),
"number.mock_offset_calibration2": State(
"number.mock_offset_calibration2", "10", {"min": -12, "max": 12}
),
},
State("unknown.entity_id", "unknown"),
)
# 1. initialize the VTherm
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
# fmt: off
with patch("custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event") as mock_send_event, \
patch("custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate", side_effect=[fake_underlying_climate1, fake_underlying_climate2]) as mock_find_climate, \
patch("homeassistant.core.ServiceRegistry.async_call") as mock_service_call,\
patch("homeassistant.core.StateMachine.get", side_effect=mock_get_state_side_effect.get_side_effects()) as mock_get_state:
# fmt: on
vtherm: ThermostatOverClimateValve = await create_thermostat(hass, entry, "climate.theoverclimatemockname")
assert vtherm
assert isinstance(vtherm, ThermostatOverClimateValve)
assert vtherm.name == "TheOverClimateMockName"
assert vtherm.is_over_climate is True
assert vtherm.have_valve_regulation is True
vtherm._set_now(now)
# initialize the temps
await set_all_climate_preset_temp(hass, vtherm, default_temperatures, "theoverclimatemockname")
await send_temperature_change_event(vtherm, 20, now, True)
await send_ext_temperature_change_event(vtherm, 20, now, True)
await send_presence_change_event(vtherm, False, True, now)
await vtherm.async_set_preset_mode(PRESET_COMFORT)
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
assert vtherm.target_temperature == 19
assert vtherm.nb_device_actives == 0
# 2: set temperature -> should activate the valve and change target
# fmt: off
with patch("custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event") as mock_send_event, \
patch("homeassistant.core.ServiceRegistry.async_call") as mock_service_call,\
patch("homeassistant.core.StateMachine.get", side_effect=mock_get_state_side_effect.get_side_effects()) as mock_get_state:
# fmt: on
now = now + timedelta(minutes=3)
vtherm._set_now(now)
await send_temperature_change_event(vtherm, 18, now, True)
await hass.async_block_till_done()
assert vtherm.is_device_active is True
assert vtherm.valve_open_percent == 20
# the underlying set temperature call and the call to the valve
assert mock_service_call.call_count == 6
mock_service_call.assert_has_calls([
# min is 60
call(domain='number', service='set_value', service_data={'value': 60}, target={'entity_id': 'number.mock_opening_degree1'}),
call(domain='number', service='set_value', service_data={'value': 40}, target={'entity_id': 'number.mock_closing_degree1'}),
call(domain='number', service='set_value', service_data={'value': 3.0}, target={'entity_id': 'number.mock_offset_calibration1'}),
call(domain='number', service='set_value', service_data={'value': 70}, target={'entity_id': 'number.mock_opening_degree2'}),
call(domain='number', service='set_value', service_data={'value': 30}, target={'entity_id': 'number.mock_closing_degree2'}),
call(domain='number', service='set_value', service_data={'value': 12}, target={'entity_id': 'number.mock_offset_calibration2'})
]
)
assert vtherm.nb_device_actives >= 2 # should be 2 but when run in // with the first test it give 3
# 3: set high temperature -> should deactivate the valve and change target
# fmt: off
with patch("custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event") as mock_send_event, \
patch("homeassistant.core.ServiceRegistry.async_call") as mock_service_call,\
patch("homeassistant.core.StateMachine.get", side_effect=mock_get_state_side_effect.get_side_effects()) as mock_get_state:
# fmt: on
now = now + timedelta(minutes=3)
vtherm._set_now(now)
await send_temperature_change_event(vtherm, 22, now, True)
await hass.async_block_till_done()
assert vtherm.is_device_active is False
assert vtherm.valve_open_percent == 0
# the underlying set temperature call and the call to the valve
assert mock_service_call.call_count == 6
mock_service_call.assert_has_calls([
call(domain='number', service='set_value', service_data={'value': 0}, target={'entity_id': 'number.mock_opening_degree1'}),
call(domain='number', service='set_value', service_data={'value': 100}, target={'entity_id': 'number.mock_closing_degree1'}),
call(domain='number', service='set_value', service_data={'value': 7.0}, target={'entity_id': 'number.mock_offset_calibration1'}),
call(domain='number', service='set_value', service_data={'value': 0}, target={'entity_id': 'number.mock_opening_degree2'}),
call(domain='number', service='set_value', service_data={'value': 100}, target={'entity_id': 'number.mock_closing_degree2'}),
call(domain='number', service='set_value', service_data={'value': 12}, target={'entity_id': 'number.mock_offset_calibration2'})
]
)
assert vtherm.nb_device_actives == 0

View File

@@ -1,17 +1,243 @@
# pylint: disable=protected-access, unused-argument, line-too-long
""" Test the Power management """
from unittest.mock import patch, call
from unittest.mock import patch, call, AsyncMock, MagicMock, PropertyMock
from datetime import datetime, timedelta
import logging
from custom_components.versatile_thermostat.thermostat_switch import (
ThermostatOverSwitch,
)
from custom_components.versatile_thermostat.feature_power_manager import (
FeaturePowerManager,
)
from custom_components.versatile_thermostat.prop_algorithm import PropAlgorithm
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
logging.getLogger().setLevel(logging.DEBUG)
@pytest.mark.parametrize(
"is_over_climate, is_device_active, power, max_power, current_overpowering_state, overpowering_state, nb_call, changed, check_overpowering_ret",
[
# don't switch to overpower (power is enough)
(False, False, 1000, 3000, STATE_OFF, STATE_OFF, 0, True, False),
# switch to overpower (power is not enough)
(False, False, 2000, 3000, STATE_OFF, STATE_ON, 1, True, True),
# don't switch to overpower (power is not enough but device is already on)
(False, True, 2000, 3000, STATE_OFF, STATE_OFF, 0, True, False),
# Same with a over_climate
# don't switch to overpower (power is enough)
(True, False, 1000, 3000, STATE_OFF, STATE_OFF, 0, True, False),
# switch to overpower (power is not enough)
(True, False, 2000, 3000, STATE_OFF, STATE_ON, 1, True, True),
# don't switch to overpower (power is not enough but device is already on)
(True, True, 2000, 3000, STATE_OFF, STATE_OFF, 0, True, False),
# Leave overpowering state
# switch to not overpower (power is enough)
(False, False, 1000, 3000, STATE_ON, STATE_OFF, 1, True, False),
# don't switch to overpower (power is still not enough)
(False, False, 2000, 3000, STATE_ON, STATE_ON, 0, True, True),
# keep overpower (power is not enough but device is already on)
(False, True, 3000, 3000, STATE_ON, STATE_ON, 0, True, True),
],
)
async def test_power_feature_manager(
hass: HomeAssistant,
is_over_climate,
is_device_active,
power,
max_power,
current_overpowering_state,
overpowering_state,
nb_call,
changed,
check_overpowering_ret,
):
"""Test the FeaturePresenceManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
# 1. creation
power_manager = FeaturePowerManager(fake_vtherm, hass)
assert power_manager is not None
assert power_manager.is_configured is False
assert power_manager.overpowering_state == STATE_UNAVAILABLE
assert power_manager.name == "the name"
assert len(power_manager._active_listener) == 0
custom_attributes = {}
power_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["power_sensor_entity_id"] is None
assert custom_attributes["max_power_sensor_entity_id"] is None
assert custom_attributes["overpowering_state"] == STATE_UNAVAILABLE
assert custom_attributes["is_power_configured"] is False
assert custom_attributes["device_power"] is 0
assert custom_attributes["power_temp"] is None
assert custom_attributes["current_power"] is None
assert custom_attributes["current_max_power"] is None
# 2. post_init
power_manager.post_init(
{
CONF_POWER_SENSOR: "sensor.the_power_sensor",
CONF_MAX_POWER_SENSOR: "sensor.the_max_power_sensor",
CONF_USE_POWER_FEATURE: True,
CONF_PRESET_POWER: 10,
CONF_DEVICE_POWER: 1234,
}
)
assert power_manager.is_configured is True
assert power_manager.overpowering_state == STATE_UNKNOWN
custom_attributes = {}
power_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["power_sensor_entity_id"] == "sensor.the_power_sensor"
assert (
custom_attributes["max_power_sensor_entity_id"] == "sensor.the_max_power_sensor"
)
assert custom_attributes["overpowering_state"] == STATE_UNKNOWN
assert custom_attributes["is_power_configured"] is True
assert custom_attributes["device_power"] == 1234
assert custom_attributes["power_temp"] == 10
assert custom_attributes["current_power"] is None
assert custom_attributes["current_max_power"] is None
# 3. start listening
power_manager.start_listening()
assert power_manager.is_configured is True
assert power_manager.overpowering_state == STATE_UNKNOWN
assert len(power_manager._active_listener) == 2
# 4. test refresh and check_overpowering with the parametrized
side_effects = SideEffects(
{
"sensor.the_power_sensor": State("sensor.the_power_sensor", power),
"sensor.the_max_power_sensor": State(
"sensor.the_max_power_sensor", max_power
),
},
State("unknown.entity_id", "unknown"),
)
# fmt:off
with patch("homeassistant.core.StateMachine.get", side_effect=side_effects.get_side_effects()) as mock_get_state:
# fmt:on
# Finish the mock configuration
tpi_algo = PropAlgorithm(PROPORTIONAL_FUNCTION_TPI, 0.6, 0.01, 5, 0, "climate.vtherm")
tpi_algo._on_percent = 1 # pylint: disable="protected-access"
type(fake_vtherm).hvac_mode = PropertyMock(return_value=HVACMode.HEAT)
type(fake_vtherm).is_device_active = PropertyMock(return_value=is_device_active)
type(fake_vtherm).is_over_climate = PropertyMock(return_value=is_over_climate)
type(fake_vtherm).proportional_algorithm = PropertyMock(return_value=tpi_algo)
type(fake_vtherm).nb_underlying_entities = PropertyMock(return_value=1)
type(fake_vtherm).preset_mode = PropertyMock(return_value=PRESET_COMFORT if current_overpowering_state == STATE_OFF else PRESET_POWER)
type(fake_vtherm)._saved_preset_mode = PropertyMock(return_value=PRESET_ECO)
fake_vtherm.save_hvac_mode = MagicMock()
fake_vtherm.restore_hvac_mode = AsyncMock()
fake_vtherm.save_preset_mode = MagicMock()
fake_vtherm.restore_preset_mode = AsyncMock()
fake_vtherm.async_underlying_entity_turn_off = AsyncMock()
fake_vtherm.async_set_preset_mode_internal = AsyncMock()
fake_vtherm.send_event = MagicMock()
fake_vtherm.update_custom_attributes = MagicMock()
ret = await power_manager.refresh_state()
assert ret == changed
assert power_manager.is_configured is True
assert power_manager.overpowering_state == STATE_UNKNOWN
assert power_manager.current_power == power
assert power_manager.current_max_power == max_power
# check overpowering
power_manager._overpowering_state = current_overpowering_state
ret2 = await power_manager.check_overpowering()
assert ret2 == check_overpowering_ret
assert power_manager.overpowering_state == overpowering_state
assert mock_get_state.call_count == 2
if power_manager.overpowering_state == STATE_OFF:
assert fake_vtherm.save_hvac_mode.call_count == 0
assert fake_vtherm.save_preset_mode.call_count == 0
assert fake_vtherm.async_underlying_entity_turn_off.call_count == 0
assert fake_vtherm.async_set_preset_mode_internal.call_count == 0
assert fake_vtherm.send_event.call_count == nb_call
if current_overpowering_state == STATE_ON:
assert fake_vtherm.update_custom_attributes.call_count == 1
assert fake_vtherm.restore_preset_mode.call_count == 1
if is_over_climate:
assert fake_vtherm.restore_hvac_mode.call_count == 1
else:
assert fake_vtherm.restore_hvac_mode.call_count == 0
else:
assert fake_vtherm.update_custom_attributes.call_count == 0
if nb_call == 1:
fake_vtherm.send_event.assert_has_calls(
[
call.fake_vtherm.send_event(
EventType.POWER_EVENT,
{'type': 'end', 'current_power': power, 'device_power': 1234, 'current_max_power': max_power}),
]
)
elif power_manager.overpowering_state == STATE_ON:
if is_over_climate:
assert fake_vtherm.save_hvac_mode.call_count == 1
else:
assert fake_vtherm.save_hvac_mode.call_count == 0
if current_overpowering_state == STATE_OFF:
assert fake_vtherm.save_preset_mode.call_count == 1
assert fake_vtherm.async_underlying_entity_turn_off.call_count == 1
assert fake_vtherm.async_set_preset_mode_internal.call_count == 1
assert fake_vtherm.send_event.call_count == 1
assert fake_vtherm.update_custom_attributes.call_count == 1
else:
assert fake_vtherm.save_preset_mode.call_count == 0
assert fake_vtherm.async_underlying_entity_turn_off.call_count == 0
assert fake_vtherm.async_set_preset_mode_internal.call_count == 0
assert fake_vtherm.send_event.call_count == 0
assert fake_vtherm.update_custom_attributes.call_count == 0
assert fake_vtherm.restore_hvac_mode.call_count == 0
assert fake_vtherm.restore_preset_mode.call_count == 0
if nb_call == 1:
fake_vtherm.send_event.assert_has_calls(
[
call.fake_vtherm.send_event(
EventType.POWER_EVENT,
{'type': 'start', 'current_power': power, 'device_power': 1234, 'current_max_power': max_power, 'current_power_consumption': 1234.0}),
]
)
fake_vtherm.reset_mock()
# 5. Check custom_attributes
custom_attributes = {}
power_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["power_sensor_entity_id"] == "sensor.the_power_sensor"
assert (
custom_attributes["max_power_sensor_entity_id"] == "sensor.the_max_power_sensor"
)
assert custom_attributes["overpowering_state"] == overpowering_state
assert custom_attributes["is_power_configured"] is True
assert custom_attributes["device_power"] == 1234
assert custom_attributes["power_temp"] == 10
assert custom_attributes["current_power"] == power
assert custom_attributes["current_max_power"] == max_power
power_manager.stop_listening()
await hass.async_block_till_done()
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_power_management_hvac_off(
@@ -43,8 +269,8 @@ async def test_power_management_hvac_off(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_POWER_SENSOR: "sensor.mock_power_sensor",
CONF_MAX_POWER_SENSOR: "sensor.mock_power_max_sensor",
CONF_DEVICE_POWER: 100,
@@ -63,23 +289,23 @@ async def test_power_management_hvac_off(
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 19
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNKNOWN
assert entity.hvac_mode == HVACMode.OFF
# Send power mesurement
await send_power_change_event(entity, 50, datetime.now())
assert await entity.check_overpowering() is False
assert await entity.power_manager.check_overpowering() is False
# All configuration is not complete
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNKNOWN
# Send power max mesurement
await send_max_power_change_event(entity, 300, datetime.now())
assert await entity.check_overpowering() is False
assert await entity.power_manager.check_overpowering() is False
# All configuration is complete and power is < power_max
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is False
assert entity.power_manager.overpowering_state is STATE_OFF
# Send power max mesurement too low but HVACMode is off
with patch(
@@ -90,10 +316,10 @@ async def test_power_management_hvac_off(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off:
await send_max_power_change_event(entity, 149, datetime.now())
assert await entity.check_overpowering() is True
assert await entity.power_manager.check_overpowering() is True
# All configuration is complete and power is > power_max but we stay in Boost cause thermostat if Off
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is True
assert entity.power_manager.overpowering_state is STATE_ON
assert mock_send_event.call_count == 0
assert mock_heater_on.call_count == 0
@@ -129,8 +355,8 @@ async def test_power_management_hvac_on(hass: HomeAssistant, skip_hass_states_is
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_POWER_SENSOR: "sensor.mock_power_sensor",
CONF_MAX_POWER_SENSOR: "sensor.mock_power_max_sensor",
CONF_DEVICE_POWER: 100,
@@ -150,17 +376,17 @@ async def test_power_management_hvac_on(hass: HomeAssistant, skip_hass_states_is
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNKNOWN
assert entity.target_temperature == 19
# Send power mesurement
await send_power_change_event(entity, 50, datetime.now())
# Send power max mesurement
await send_max_power_change_event(entity, 300, datetime.now())
assert await entity.check_overpowering() is False
assert await entity.power_manager.check_overpowering() is False
# All configuration is complete and power is < power_max
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is False
assert entity.power_manager.overpowering_state is STATE_OFF
# Send power max mesurement too low and HVACMode is on
with patch(
@@ -171,10 +397,10 @@ async def test_power_management_hvac_on(hass: HomeAssistant, skip_hass_states_is
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off:
await send_max_power_change_event(entity, 149, datetime.now())
assert await entity.check_overpowering() is True
assert await entity.power_manager.check_overpowering() is True
# All configuration is complete and power is > power_max we switch to POWER preset
assert entity.preset_mode is PRESET_POWER
assert entity.overpowering_state is True
assert entity.power_manager.overpowering_state is STATE_ON
assert entity.target_temperature == 12
assert mock_send_event.call_count == 2
@@ -187,7 +413,7 @@ async def test_power_management_hvac_on(hass: HomeAssistant, skip_hass_states_is
"type": "start",
"current_power": 50,
"device_power": 100,
"current_power_max": 149,
"current_max_power": 149,
"current_power_consumption": 100.0,
},
),
@@ -206,10 +432,10 @@ async def test_power_management_hvac_on(hass: HomeAssistant, skip_hass_states_is
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off:
await send_power_change_event(entity, 48, datetime.now())
assert await entity.check_overpowering() is False
assert await entity.power_manager.check_overpowering() is False
# All configuration is complete and power is < power_max, we restore previous preset
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is False
assert entity.power_manager.overpowering_state is STATE_OFF
assert entity.target_temperature == 19
assert mock_send_event.call_count == 2
@@ -222,7 +448,7 @@ async def test_power_management_hvac_on(hass: HomeAssistant, skip_hass_states_is
"type": "end",
"current_power": 48,
"device_power": 100,
"current_power_max": 149,
"current_max_power": 149,
},
),
],
@@ -265,8 +491,8 @@ async def test_power_management_energy_over_switch(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_POWER_SENSOR: "sensor.mock_power_sensor",
CONF_MAX_POWER_SENSOR: "sensor.mock_power_max_sensor",
CONF_DEVICE_POWER: 100,
@@ -303,7 +529,7 @@ async def test_power_management_energy_over_switch(
assert entity.current_temperature == 15
assert tpi_algo.on_percent == 1
assert entity.device_power == 100.0
assert entity.power_manager.device_power == 100.0
assert mock_send_event.call_count == 2
assert mock_heater_on.call_count == 1
@@ -324,7 +550,7 @@ async def test_power_management_energy_over_switch(
) as mock_heater_off:
await send_temperature_change_event(entity, 18, datetime.now())
assert tpi_algo.on_percent == 0.3
assert entity.mean_cycle_power == 30.0
assert entity.power_manager.mean_cycle_power == 30.0
assert mock_send_event.call_count == 0
assert mock_heater_on.call_count == 0
@@ -346,7 +572,7 @@ async def test_power_management_energy_over_switch(
) as mock_heater_off:
await send_temperature_change_event(entity, 20, datetime.now())
assert tpi_algo.on_percent == 0.0
assert entity.mean_cycle_power == 0.0
assert entity.power_manager.mean_cycle_power == 0.0
assert mock_send_event.call_count == 0
assert mock_heater_on.call_count == 0
@@ -394,8 +620,8 @@ async def test_power_management_energy_over_climate(
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_POWER_SENSOR: "sensor.mock_power_sensor",
CONF_MAX_POWER_SENSOR: "sensor.mock_power_max_sensor",
CONF_DEVICE_POWER: 100,
@@ -421,7 +647,7 @@ async def test_power_management_energy_over_climate(
assert entity.current_temperature == 15
# Not initialised yet
assert entity.mean_cycle_power is None
assert entity.power_manager.mean_cycle_power is None
assert entity._underlying_climate_start_hvac_action_date is None
# Send a climate_change event with HVACAction=HEATING

178
tests/test_presence.py Normal file
View File

@@ -0,0 +1,178 @@
# pylint: disable=wildcard-import, unused-wildcard-import, protected-access, unused-argument, line-too-long
""" Test the Security featrure """
import logging
from unittest.mock import patch, call, AsyncMock, MagicMock, PropertyMock
# from datetime import timedelta, datetime
from custom_components.versatile_thermostat.base_thermostat import BaseThermostat
from custom_components.versatile_thermostat.feature_presence_manager import (
FeaturePresenceManager,
)
from .commons import *
logging.getLogger().setLevel(logging.DEBUG)
@pytest.mark.parametrize(
"temp, absence, state, nb_call, presence_state, changed",
[
(19, False, STATE_ON, 1, STATE_ON, True),
(17, True, STATE_OFF, 1, STATE_OFF, True),
(19, False, STATE_HOME, 1, STATE_ON, True),
(17, True, STATE_NOT_HOME, 1, STATE_OFF, True),
(17, False, STATE_UNAVAILABLE, 0, STATE_UNKNOWN, False),
(17, False, STATE_UNKNOWN, 0, STATE_UNKNOWN, False),
(17, False, "wrong state", 0, STATE_UNKNOWN, False),
],
)
async def test_presence_feature_manager(
hass: HomeAssistant, temp, absence, state, nb_call, presence_state, changed
):
"""Test the FeaturePresenceManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
type(fake_vtherm).preset_mode = PropertyMock(return_value=PRESET_COMFORT)
# 1. creation
presence_manager = FeaturePresenceManager(fake_vtherm, hass)
assert presence_manager is not None
assert presence_manager.is_configured is False
assert presence_manager.is_absence_detected is False
assert presence_manager.presence_state == STATE_UNAVAILABLE
assert presence_manager.name == "the name"
assert len(presence_manager._active_listener) == 0
custom_attributes = {}
presence_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["presence_sensor_entity_id"] is None
assert custom_attributes["presence_state"] == STATE_UNAVAILABLE
assert custom_attributes["is_presence_configured"] is False
# 2. post_init
presence_manager.post_init(
{
CONF_PRESENCE_SENSOR: "sensor.the_presence_sensor",
CONF_USE_PRESENCE_FEATURE: True,
}
)
assert presence_manager.is_configured is True
assert presence_manager.presence_state == STATE_UNKNOWN
assert presence_manager.is_absence_detected is False
custom_attributes = {}
presence_manager.add_custom_attributes(custom_attributes)
assert (
custom_attributes["presence_sensor_entity_id"] == "sensor.the_presence_sensor"
)
assert custom_attributes["presence_state"] == STATE_UNKNOWN
assert custom_attributes["is_presence_configured"] is True
# 3. start listening
presence_manager.start_listening()
assert presence_manager.is_configured is True
assert presence_manager.presence_state == STATE_UNKNOWN
assert presence_manager.is_absence_detected is False
assert len(presence_manager._active_listener) == 1
# 4. test refresh with the parametrized
# fmt:off
with patch("homeassistant.core.StateMachine.get", return_value=State("sensor.the_presence_sensor", state)) as mock_get_state:
# fmt:on
# Configurer les méthodes mockées
fake_vtherm.find_preset_temp.return_value = temp
fake_vtherm.change_target_temperature = AsyncMock()
fake_vtherm.async_control_heating = AsyncMock()
ret = await presence_manager.refresh_state()
assert ret == changed
assert presence_manager.is_configured is True
assert presence_manager.presence_state == presence_state
assert presence_manager.is_absence_detected is absence
assert mock_get_state.call_count == 1
assert fake_vtherm.find_preset_temp.call_count == nb_call
if nb_call == 1:
fake_vtherm.find_preset_temp.assert_has_calls(
[
call.find_preset_temp(PRESET_COMFORT),
]
)
assert fake_vtherm.change_target_temperature.call_count == nb_call
fake_vtherm.change_target_temperature.assert_has_calls(
[
call.find_preset_temp(temp),
]
)
assert fake_vtherm.async_control_heating.call_count == 0
fake_vtherm.reset_mock()
# 5. Check custom_attributes
custom_attributes = {}
presence_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["presence_sensor_entity_id"] == "sensor.the_presence_sensor"
assert custom_attributes["presence_state"] == presence_state
assert custom_attributes["is_presence_configured"] is True
# 6. test _presence_sensor_changed with the parametrized
fake_vtherm.find_preset_temp.return_value = temp
fake_vtherm.change_target_temperature = AsyncMock()
fake_vtherm.async_control_heating = AsyncMock()
await presence_manager._presence_sensor_changed(
event=Event(
event_type=EVENT_STATE_CHANGED,
data={
"entity_id": "sensor.the_presence_sensor",
"new_state": State("sensor.the_presence_sensor", state),
"old_state": State("sensor.the_presence_sensor", STATE_UNAVAILABLE),
}))
assert ret == changed
assert presence_manager.is_configured is True
assert presence_manager.presence_state == presence_state
assert presence_manager.is_absence_detected is absence
assert fake_vtherm.find_preset_temp.call_count == nb_call
if nb_call == 1:
fake_vtherm.find_preset_temp.assert_has_calls(
[
call.find_preset_temp(PRESET_COMFORT),
]
)
assert fake_vtherm.change_target_temperature.call_count == nb_call
fake_vtherm.change_target_temperature.assert_has_calls(
[
call.find_preset_temp(temp),
]
)
assert fake_vtherm.async_control_heating.call_count == 1
fake_vtherm.async_control_heating.assert_has_calls([
call.async_control_heating(force=True)
])
fake_vtherm.reset_mock()
# 7. Check custom_attributes
custom_attributes = {}
presence_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["presence_sensor_entity_id"] == "sensor.the_presence_sensor"
assert custom_attributes["presence_state"] == presence_state
assert custom_attributes["is_presence_configured"] is True
presence_manager.stop_listening()
await hass.async_block_till_done()

View File

@@ -1,7 +1,7 @@
# pylint: disable=wildcard-import, unused-wildcard-import, protected-access, unused-argument, line-too-long
""" Test the Security featrure """
from unittest.mock import patch, call
from unittest.mock import patch, call, PropertyMock, MagicMock
from datetime import timedelta, datetime
import logging
@@ -11,12 +11,103 @@ from custom_components.versatile_thermostat.thermostat_climate import (
from custom_components.versatile_thermostat.thermostat_switch import (
ThermostatOverSwitch,
)
from custom_components.versatile_thermostat.feature_safety_manager import (
FeatureSafetyManager,
)
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
logging.getLogger().setLevel(logging.DEBUG)
async def test_safety_feature_manager_create(
hass: HomeAssistant,
):
"""Test the FeatureMotionManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
# 1. creation
safety_manager = FeatureSafetyManager(fake_vtherm, hass)
assert safety_manager is not None
assert safety_manager.is_configured is False
assert safety_manager.is_safety_detected is False
assert safety_manager.safety_state is STATE_UNAVAILABLE
assert safety_manager.name == "the name"
assert len(safety_manager._active_listener) == 0
custom_attributes = {}
safety_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["is_safety_configured"] is False
assert custom_attributes["safety_state"] is STATE_UNAVAILABLE
assert custom_attributes.get("safety_delay_min", None) is None
assert custom_attributes.get("safety_min_on_percent", None) is None
assert custom_attributes.get("safety_default_on_percent", None) is None
@pytest.mark.parametrize(
"safety_delay_min, safety_min_on_percent, safety_default_on_percent, is_configured, state",
[
# fmt: off
( 10, 11, 12, True, STATE_UNKNOWN),
( None, 11, 12, False, STATE_UNAVAILABLE),
( 10, None, 12, True, STATE_UNKNOWN),
( 10, 11, None, True, STATE_UNKNOWN),
( 10, None, None, True, STATE_UNKNOWN),
( None, None, None, False, STATE_UNAVAILABLE),
# fmt: on
],
)
async def test_safety_feature_manager_post_init(
hass: HomeAssistant,
safety_delay_min,
safety_min_on_percent,
safety_default_on_percent,
is_configured,
state,
):
"""Test the FeatureSafetyManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
# 1. creation
safety_manager = FeatureSafetyManager(fake_vtherm, hass)
assert safety_manager is not None
# 2. post_init
safety_manager.post_init(
{
CONF_SAFETY_DELAY_MIN: safety_delay_min,
CONF_SAFETY_MIN_ON_PERCENT: safety_min_on_percent,
CONF_SAFETY_DEFAULT_ON_PERCENT: safety_default_on_percent,
}
)
assert safety_manager.is_configured is is_configured
assert safety_manager.safety_state is state
custom_attributes = {}
safety_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["is_safety_configured"] is is_configured
assert custom_attributes["safety_state"] is state
if safety_manager.is_configured:
assert custom_attributes.get("safety_delay_min", None) == safety_delay_min
assert (
custom_attributes.get("safety_min_on_percent", None)
== safety_min_on_percent
or DEFAULT_SAFETY_MIN_ON_PERCENT
)
assert (
custom_attributes.get("safety_default_on_percent", None)
== safety_default_on_percent
or DEFAULT_SAFETY_DEFAULT_ON_PERCENT
)
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_security_feature(hass: HomeAssistant, skip_hass_states_is_state):
@@ -24,17 +115,26 @@ async def test_security_feature(hass: HomeAssistant, skip_hass_states_is_state):
1. creates a thermostat and check that security is off
2. activate security feature when date is expired
3. change the preset to boost
4. check that security is still on
5. resolve the date issue
6. check that security is off and preset is changed to boost
"""
tz = get_tz(hass) # pylint: disable=invalid-name
temps = {
"frost": 7,
"eco": 17,
"comfort": 18,
"boost": 19,
}
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverSwitchMockName",
unique_id="uniqueId",
# With migration
version=CONFIG_VERSION,
minor_version=0,
data={
"name": "TheOverSwitchMockName",
"thermostat_type": "thermostat_over_switch",
@@ -43,15 +143,11 @@ async def test_security_feature(hass: HomeAssistant, skip_hass_states_is_state):
"cycle_min": 5,
"temp_min": 15,
"temp_max": 30,
"frost_temp": 7,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 19,
"use_window_feature": False,
"use_motion_feature": False,
"use_power_feature": False,
"use_presence_feature": False,
"heater_entity_id": "switch.mock_switch",
CONF_UNDERLYING_LIST: ["switch.mock_switch"],
"proportional_function": "tpi",
"tpi_coef_int": 0.3,
"tpi_coef_ext": 0.01,
@@ -69,8 +165,11 @@ async def test_security_feature(hass: HomeAssistant, skip_hass_states_is_state):
)
assert entity
assert entity._security_state is False
assert entity.preset_mode is not PRESET_SECURITY
await set_all_climate_preset_temp(hass, entity, temps, "theoverswitchmockname")
assert entity.safety_manager.safety_state is not STATE_ON
assert entity.safety_manager.is_safety_detected is False
assert entity.preset_mode is not PRESET_SAFETY
assert entity.preset_modes == [
PRESET_NONE,
PRESET_FROST_PROTECTION,
@@ -105,8 +204,8 @@ async def test_security_feature(hass: HomeAssistant, skip_hass_states_is_state):
# set temperature to 15 so that on_percent will be > security_min_on_percent (0.2)
await send_temperature_change_event(entity, 15, event_timestamp)
assert entity.security_state is True
assert entity.preset_mode == PRESET_SECURITY
assert entity.safety_state is STATE_ON
assert entity.preset_mode == PRESET_SAFETY
assert entity._saved_preset_mode == PRESET_COMFORT
assert entity._prop_algorithm.on_percent == 0.1
assert entity._prop_algorithm.calculated_on_percent == 0.9
@@ -114,7 +213,7 @@ async def test_security_feature(hass: HomeAssistant, skip_hass_states_is_state):
assert mock_send_event.call_count == 3
mock_send_event.assert_has_calls(
[
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_SECURITY}),
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_SAFETY}),
call.send_event(
EventType.TEMPERATURE_EVENT,
{
@@ -151,11 +250,13 @@ async def test_security_feature(hass: HomeAssistant, skip_hass_states_is_state):
await entity.async_set_preset_mode(PRESET_BOOST)
# 4. check that security is still on
assert entity._security_state is True
assert entity.safety_manager.safety_state is STATE_ON
assert entity.safety_manager.is_safety_detected is True
assert entity._prop_algorithm.on_percent == 0.1
assert entity._prop_algorithm.calculated_on_percent == 0.9
assert entity._saved_preset_mode == PRESET_BOOST
assert entity.preset_mode is PRESET_SECURITY
assert entity.preset_mode is PRESET_SAFETY
# 5. resolve the datetime issue
with patch(
@@ -168,7 +269,9 @@ async def test_security_feature(hass: HomeAssistant, skip_hass_states_is_state):
# set temperature to 15 so that on_percent will be > security_min_on_percent (0.2)
await send_temperature_change_event(entity, 15.2, event_timestamp)
assert entity._security_state is False
assert entity.safety_manager.safety_state is not STATE_ON
assert entity.safety_manager.is_safety_detected is False
assert entity.preset_mode == PRESET_BOOST
assert entity._saved_preset_mode == PRESET_BOOST
assert entity._prop_algorithm.on_percent == 1.0
@@ -215,6 +318,12 @@ async def test_security_feature_back_on_percent(
"""
tz = get_tz(hass) # pylint: disable=invalid-name
temps = {
"eco": 17,
"comfort": 18,
"boost": 19,
"frost": 10,
}
entry = MockConfigEntry(
domain=DOMAIN,
@@ -228,21 +337,18 @@ async def test_security_feature_back_on_percent(
"cycle_min": 5,
"temp_min": 15,
"temp_max": 30,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 19,
"use_window_feature": False,
"use_motion_feature": False,
"use_power_feature": False,
"use_presence_feature": False,
"heater_entity_id": "switch.mock_switch",
CONF_UNDERLYING_LIST: ["switch.mock_switch"],
"proportional_function": "tpi",
"tpi_coef_int": 0.3,
"tpi_coef_ext": 0.01,
"minimal_activation_delay": 30,
"security_delay_min": 5, # 5 minutes
"security_min_on_percent": 0.2,
"security_default_on_percent": 0.1,
"safety_delay_min": 5, # 5 minutes
"safety_min_on_percent": 0.2,
"safety_default_on_percent": 0.1,
},
)
@@ -253,8 +359,12 @@ async def test_security_feature_back_on_percent(
)
assert entity
assert entity._security_state is False
assert entity.preset_mode is not PRESET_SECURITY
await set_all_climate_preset_temp(hass, entity, temps, "theoverswitchmockname")
assert entity.safety_manager.safety_state is not STATE_ON
assert entity.safety_manager.is_safety_detected is False
assert entity.preset_mode is not PRESET_SAFETY
assert entity._last_ext_temperature_measure is not None
assert entity._last_temperature_measure is not None
assert (entity._last_temperature_measure.astimezone(tz) - now).total_seconds() < 1
@@ -285,7 +395,7 @@ async def test_security_feature_back_on_percent(
await send_temperature_change_event(entity, 17, event_timestamp)
assert entity._prop_algorithm.calculated_on_percent == 0.6
assert entity.preset_mode == PRESET_BOOST
assert entity.security_state is False
assert entity.safety_state is not STATE_ON
assert mock_send_event.call_count == 0
# 3. Set safety mode with a preset change
@@ -302,14 +412,14 @@ async def test_security_feature_back_on_percent(
assert entity._prop_algorithm.calculated_on_percent == 0.6
assert entity.security_state is True
assert entity.preset_mode == PRESET_SECURITY
assert entity.safety_state is STATE_ON
assert entity.preset_mode == PRESET_SAFETY
assert entity._saved_preset_mode == PRESET_BOOST
assert mock_send_event.call_count == 3
mock_send_event.assert_has_calls(
[
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_SECURITY}),
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_SAFETY}),
call.send_event(
EventType.TEMPERATURE_EVENT,
{
@@ -343,8 +453,8 @@ async def test_security_feature_back_on_percent(
entity._set_now(event_timestamp) # pylint: disable=protected-access
await entity.async_set_preset_mode(PRESET_ECO)
assert entity.security_state is True
assert entity.preset_mode == PRESET_SECURITY
assert entity.safety_state is STATE_ON
assert entity.preset_mode == PRESET_SAFETY
# 5. resolve the datetime issue
with patch(
@@ -359,7 +469,9 @@ async def test_security_feature_back_on_percent(
# set temperature to 18.9 so that on_percent will be > security_min_on_percent (0.2)
await send_temperature_change_event(entity, 18.92, event_timestamp)
assert entity._security_state is False
assert entity.safety_manager.safety_state is not STATE_ON
assert entity.safety_manager.is_safety_detected is False
assert entity.preset_mode == PRESET_ECO
assert entity._saved_preset_mode == PRESET_ECO
assert entity._prop_algorithm.on_percent == 0.0
@@ -452,7 +564,8 @@ async def test_security_over_climate(
PRESET_BOOST,
]
assert entity.preset_mode is PRESET_NONE
assert entity._security_state is False
assert entity.safety_manager.safety_state is not STATE_ON
assert entity.safety_manager.is_safety_detected is False
# should have been called with EventType.PRESET_EVENT and EventType.HVAC_MODE_EVENT
assert mock_send_event.call_count == 2
@@ -506,6 +619,56 @@ async def test_security_over_climate(
await send_temperature_change_event(entity, 15, event_timestamp)
# Should stay False because a climate is never in safety mode
assert entity.security_state is False
assert entity.safety_state is not STATE_ON
assert entity.preset_mode == "none"
assert entity._saved_preset_mode == "none"
async def test_migration_security_safety(
hass: HomeAssistant,
skip_hass_states_is_state,
):
"""Tests the migration of security parameters to safety in English"""
central_config_entry = MockConfigEntry(
# Current is 2.1
version=CONFIG_VERSION,
# An old minor version
minor_version=0,
domain=DOMAIN,
title="TheCentralConfigMockName",
unique_id="centralConfigUniqueId",
data={
CONF_NAME: "migrationName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_SWITCH,
CONF_UNDERLYING_LIST: ["switch.under1"],
"security_delay_min": 61,
"security_min_on_percent": 0.5,
"security_default_on_percent": 0.2,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_DEVICE_POWER: 1,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.1,
CONF_USE_MAIN_CENTRAL_CONFIG: False,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_MINIMAL_ACTIVATION_DELAY: 10,
},
)
central_config_entry.add_to_hass(hass)
await hass.config_entries.async_setup(central_config_entry.entry_id)
assert central_config_entry.state is ConfigEntryState.LOADED
entity: ThermostatOverSwitch = search_entity(
hass, "climate.migrationname", "climate"
)
assert entity is not None
assert entity.safety_manager.safety_min_on_percent == 0.5
assert entity.safety_manager.safety_default_on_percent == 0.2
assert entity.safety_manager.safety_delay_min == 61

View File

@@ -62,8 +62,8 @@ async def test_sensors_over_switch(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_DEVICE_POWER: 200,
},
)
@@ -222,8 +222,8 @@ async def test_sensors_over_climate(
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_POWER_SENSOR: "sensor.mock_power_sensor",
CONF_MAX_POWER_SENSOR: "sensor.mock_power_max_sensor",
CONF_DEVICE_POWER: 1.5,
@@ -360,8 +360,8 @@ async def test_sensors_over_climate_minimal(
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
},
)

View File

@@ -53,10 +53,10 @@ async def test_over_switch_full_start(hass: HomeAssistant, skip_hass_states_is_s
PRESET_ACTIVITY,
]
assert entity.preset_mode is PRESET_NONE
assert entity._security_state is False
assert entity._window_state is None
assert entity._motion_state is None
assert entity._presence_state is None
assert entity.safety_manager.is_safety_detected is False
assert entity.window_state is STATE_UNKNOWN
assert entity.motion_state is STATE_UNKNOWN
assert entity.presence_state is STATE_UNKNOWN
assert entity._prop_algorithm is not None
assert entity.have_valve_regulation is False
@@ -112,10 +112,10 @@ async def test_over_climate_full_start(hass: HomeAssistant, skip_hass_states_is_
PRESET_BOOST,
]
assert entity.preset_mode is PRESET_NONE
assert entity._security_state is False
assert entity._window_state is None
assert entity._motion_state is None
assert entity._presence_state is None
assert entity.safety_manager.is_safety_detected is False
assert entity.window_state is STATE_UNAVAILABLE
assert entity.motion_state is STATE_UNAVAILABLE
assert entity.presence_state is STATE_UNAVAILABLE
assert entity.have_valve_regulation is False
# should have been called with EventType.PRESET_EVENT and EventType.HVAC_MODE_EVENT
@@ -151,18 +151,6 @@ async def test_over_4switch_full_start(hass: HomeAssistant, skip_hass_states_is_
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event:
entity = await create_thermostat(hass, entry, "climate.theover4switchmockname")
# entry.add_to_hass(hass)
# await hass.config_entries.async_setup(entry.entry_id)
# assert entry.state is ConfigEntryState.LOADED
#
# def find_my_entity(entity_id) -> ClimateEntity:
# """Find my new entity"""
# component: EntityComponent[ClimateEntity] = hass.data[CLIMATE_DOMAIN]
# for entity in component.entities:
# if entity.entity_id == entity_id:
# return entity
#
# entity: BaseThermostat = find_my_entity("climate.theover4switchmockname")
assert entity
@@ -180,10 +168,10 @@ async def test_over_4switch_full_start(hass: HomeAssistant, skip_hass_states_is_
PRESET_ACTIVITY,
]
assert entity.preset_mode is PRESET_NONE
assert entity._security_state is False
assert entity._window_state is None
assert entity._motion_state is None
assert entity._presence_state is None
assert entity.safety_manager.is_safety_detected is False
assert entity.window_state is STATE_UNKNOWN
assert entity.motion_state is STATE_UNKNOWN
assert entity.presence_state is STATE_UNKNOWN
assert entity._prop_algorithm is not None
assert entity.nb_underlying_entities == 4
@@ -242,7 +230,7 @@ async def test_over_switch_deactivate_preset(
CONF_HEATER_3: None,
CONF_HEATER_4: None,
CONF_HEATER_KEEP_ALIVE: 0,
CONF_SECURITY_DELAY_MIN: 10,
CONF_SAFETY_DELAY_MIN: 10,
CONF_MINIMAL_ACTIVATION_DELAY: 10,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.6,

View File

@@ -89,10 +89,10 @@ async def test_over_switch_ac_full_start(
PRESET_ACTIVITY,
]
assert entity.preset_mode is PRESET_NONE
assert entity._security_state is False # pylint: disable=protected-access
assert entity._window_state is None # pylint: disable=protected-access
assert entity._motion_state is None # pylint: disable=protected-access
assert entity._presence_state is None # pylint: disable=protected-access
assert entity.safety_manager.is_safety_detected is False
assert entity.window_state is STATE_UNKNOWN
assert entity.motion_state is STATE_UNKNOWN
assert entity.presence_state is STATE_UNKNOWN
assert entity._prop_algorithm is not None # pylint: disable=protected-access
# should have been called with EventType.PRESET_EVENT and EventType.HVAC_MODE_EVENT
@@ -114,7 +114,7 @@ async def test_over_switch_ac_full_start(
event_timestamp = now - timedelta(minutes=4)
await send_presence_change_event(entity, True, False, event_timestamp)
assert entity._presence_state == STATE_ON # pylint: disable=protected-access
assert entity.presence_state == STATE_ON # pylint: disable=protected-access
await entity.async_set_hvac_mode(HVACMode.COOL)
assert entity.hvac_mode is HVACMode.COOL
@@ -131,7 +131,7 @@ async def test_over_switch_ac_full_start(
# Unset the presence
event_timestamp = now - timedelta(minutes=3)
await send_presence_change_event(entity, False, True, event_timestamp)
assert entity._presence_state == STATE_OFF # pylint: disable=protected-access
assert entity.presence_state == STATE_OFF # pylint: disable=protected-access
assert entity.target_temperature == 27 # eco_ac_away
# Open a window

View File

@@ -39,8 +39,8 @@ def config_entry() -> MockConfigEntry:
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.1,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.1,
},
)

View File

@@ -75,9 +75,9 @@ async def test_add_number_for_central_config(
CONF_MAX_POWER_SENSOR: "sensor.mock_central_max_power_sensor",
CONF_PRESET_POWER: 14,
CONF_MINIMAL_ACTIVATION_DELAY: 11,
CONF_SECURITY_DELAY_MIN: 61,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.2,
CONF_SAFETY_DELAY_MIN: 61,
CONF_SAFETY_MIN_ON_PERCENT: 0.5,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.2,
CONF_USE_CENTRAL_BOILER_FEATURE: False,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
}
@@ -170,9 +170,9 @@ async def test_add_number_for_central_config_without_temp(
CONF_MAX_POWER_SENSOR: "sensor.mock_central_max_power_sensor",
CONF_PRESET_POWER: 14,
CONF_MINIMAL_ACTIVATION_DELAY: 11,
CONF_SECURITY_DELAY_MIN: 61,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.2,
CONF_SAFETY_DELAY_MIN: 61,
CONF_SAFETY_MIN_ON_PERCENT: 0.5,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.2,
CONF_USE_CENTRAL_BOILER_FEATURE: False,
},
# | temps,
@@ -265,9 +265,9 @@ async def test_add_number_for_central_config_without_temp_ac_mode(
CONF_MAX_POWER_SENSOR: "sensor.mock_central_max_power_sensor",
CONF_PRESET_POWER: 14,
CONF_MINIMAL_ACTIVATION_DELAY: 11,
CONF_SECURITY_DELAY_MIN: 61,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.2,
CONF_SAFETY_DELAY_MIN: 61,
CONF_SAFETY_MIN_ON_PERCENT: 0.5,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.2,
CONF_USE_CENTRAL_BOILER_FEATURE: False,
},
# | temps,
@@ -359,9 +359,9 @@ async def test_add_number_for_central_config_without_temp_restore(
CONF_MAX_POWER_SENSOR: "sensor.mock_central_max_power_sensor",
CONF_PRESET_POWER: 14,
CONF_MINIMAL_ACTIVATION_DELAY: 11,
CONF_SECURITY_DELAY_MIN: 61,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.2,
CONF_SAFETY_DELAY_MIN: 61,
CONF_SAFETY_MIN_ON_PERCENT: 0.5,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.2,
CONF_USE_CENTRAL_BOILER_FEATURE: False,
},
# | temps,

View File

@@ -38,8 +38,8 @@ async def test_tpi_calculation(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
# CONF_DEVICE_POWER: 100,
},
)
@@ -58,7 +58,7 @@ async def test_tpi_calculation(
assert tpi_algo.calculated_on_percent == 1
assert tpi_algo.on_time_sec == 300
assert tpi_algo.off_time_sec == 0
assert entity.mean_cycle_power is None # no device power configured
assert entity.power_manager.mean_cycle_power is None # no device power configured
tpi_algo.calculate(15, 14, 5, HVACMode.HEAT)
assert tpi_algo.on_percent == 0.4
@@ -66,14 +66,14 @@ async def test_tpi_calculation(
assert tpi_algo.on_time_sec == 120
assert tpi_algo.off_time_sec == 180
tpi_algo.set_security(0.1)
tpi_algo.set_safety(0.1)
tpi_algo.calculate(15, 14, 5, HVACMode.HEAT)
assert tpi_algo.on_percent == 0.1
assert tpi_algo.calculated_on_percent == 0.4
assert tpi_algo.on_time_sec == 30 # >= minimal_activation_delay (=30)
assert tpi_algo.off_time_sec == 270
tpi_algo.unset_security()
tpi_algo.unset_safety()
tpi_algo.calculate(15, 14, 5, HVACMode.HEAT)
assert tpi_algo.on_percent == 0.4
assert tpi_algo.calculated_on_percent == 0.4
@@ -87,30 +87,30 @@ async def test_tpi_calculation(
assert tpi_algo.on_time_sec == 0
assert tpi_algo.off_time_sec == 300
tpi_algo.set_security(0.09)
tpi_algo.set_safety(0.09)
tpi_algo.calculate(15, 14.7, 15, HVACMode.HEAT)
assert tpi_algo.on_percent == 0.09
assert tpi_algo.calculated_on_percent == 0.09
assert tpi_algo.on_time_sec == 0
assert tpi_algo.off_time_sec == 300
tpi_algo.unset_security()
tpi_algo.unset_safety()
tpi_algo.calculate(25, 30, 35, HVACMode.COOL)
assert tpi_algo.on_percent == 1
assert tpi_algo.calculated_on_percent == 1
assert tpi_algo.on_time_sec == 300
assert tpi_algo.off_time_sec == 0
assert entity.mean_cycle_power is None # no device power configured
assert entity.power_manager.mean_cycle_power is None # no device power configured
tpi_algo.set_security(0.09)
tpi_algo.set_safety(0.09)
tpi_algo.calculate(25, 30, 35, HVACMode.COOL)
assert tpi_algo.on_percent == 0.09
assert tpi_algo.calculated_on_percent == 1
assert tpi_algo.on_time_sec == 0
assert tpi_algo.off_time_sec == 300
assert entity.mean_cycle_power is None # no device power configured
assert entity.power_manager.mean_cycle_power is None # no device power configured
tpi_algo.unset_security()
tpi_algo.unset_safety()
# The calculated values for HVACMode.OFF are the same as for HVACMode.HEAT.
tpi_algo.calculate(15, 10, 7, HVACMode.OFF)
assert tpi_algo.on_percent == 1

View File

@@ -60,8 +60,8 @@ async def test_over_valve_full_start(
PRESET_BOOST + PRESET_AWAY_SUFFIX + PRESET_TEMP_SUFFIX: 17.3,
CONF_PRESET_POWER: 10,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_DEVICE_POWER: 100,
CONF_AC_MODE: False,
},
@@ -98,10 +98,12 @@ async def test_over_valve_full_start(
PRESET_ACTIVITY,
]
assert entity.preset_mode is PRESET_NONE
assert entity._security_state is False # pylint: disable=protected-access
assert entity._window_state is None # pylint: disable=protected-access
assert entity._motion_state is None # pylint: disable=protected-access
assert entity._presence_state is None # pylint: disable=protected-access
assert (
entity.safety_manager.is_safety_detected is False
) # pylint: disable=protected-access
assert entity.window_state is STATE_UNKNOWN
assert entity.motion_state is STATE_UNKNOWN
assert entity.presence_state is STATE_UNKNOWN
assert entity._prop_algorithm is not None # pylint: disable=protected-access
assert entity.have_valve_regulation is False
@@ -350,8 +352,8 @@ async def test_over_valve_regulation(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 60,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 60,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
# only send new valve open percent if dtemp is > 30%
CONF_AUTO_REGULATION_DTEMP: 5,
# only send new valve open percent last mesure was more than 5 min ago
@@ -589,7 +591,7 @@ async def test_bug_533(
CONF_VALVE: "number.mock_valve",
CONF_AUTO_REGULATION_DTEMP: 10, # This parameter makes the bug
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 60,
CONF_SAFETY_DELAY_MIN: 60,
},
# | temps,
)

View File

@@ -9,11 +9,11 @@ from custom_components.versatile_thermostat.base_thermostat import BaseThermosta
from custom_components.versatile_thermostat.thermostat_climate import (
ThermostatOverClimate,
)
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
logging.getLogger().setLevel(logging.DEBUG)
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_window_management_time_not_enough(
@@ -45,8 +45,8 @@ async def test_window_management_time_not_enough(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_SENSOR: "binary_sensor.mock_window_sensor",
CONF_WINDOW_DELAY: 0, # important to not been obliged to wait
CONF_WINDOW_ACTION: CONF_WINDOW_TURN_OFF,
@@ -65,10 +65,10 @@ async def test_window_management_time_not_enough(
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNAVAILABLE
assert entity.target_temperature == 19
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNKNOWN
# Open the window, but condition of time is not satisfied and check the thermostat don't turns off
with patch(
@@ -134,8 +134,8 @@ async def test_window_management_time_enough(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_SENSOR: "binary_sensor.mock_window_sensor",
CONF_WINDOW_DELAY: 0, # important to not been obliged to wait
CONF_WINDOW_ACTION: CONF_WINDOW_TURN_OFF,
@@ -154,10 +154,10 @@ async def test_window_management_time_enough(
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNAVAILABLE
assert entity.target_temperature == 19
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNKNOWN
# change temperature to force turning on the heater
with patch(
@@ -246,7 +246,7 @@ async def test_window_management_time_enough(
assert entity.preset_mode is PRESET_BOOST
assert entity.hvac_mode is HVACMode.HEAT
assert entity._saved_hvac_mode is HVACMode.HEAT # No change
assert entity.hvac_off_reason == None
assert entity.hvac_off_reason is None
# Clean the entity
entity.remove_thermostat()
@@ -281,8 +281,8 @@ async def test_window_auto_fast(hass: HomeAssistant, skip_hass_states_is_state):
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_AUTO_OPEN_THRESHOLD: 0.1,
CONF_WINDOW_AUTO_CLOSE_THRESHOLD: 0.1,
CONF_WINDOW_AUTO_MAX_DURATION: 10, # Should be 0 for test
@@ -304,11 +304,11 @@ async def test_window_auto_fast(hass: HomeAssistant, skip_hass_states_is_state):
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNAVAILABLE
assert entity.target_temperature == 21
assert entity.window_state is STATE_OFF
assert entity.is_window_auto_enabled is True
assert entity.window_state is STATE_UNKNOWN
assert entity.window_manager.is_window_auto_configured is True
# Initialize the slope algo with 2 measurements
event_timestamp = now + timedelta(minutes=1)
@@ -337,8 +337,12 @@ async def test_window_auto_fast(hass: HomeAssistant, skip_hass_states_is_state):
assert mock_send_event.call_count == 0
assert entity.is_device_active is True
assert entity.last_temperature_slope == 0.0
assert entity._window_auto_algo.is_window_open_detected() is False
assert entity._window_auto_algo.is_window_close_detected() is False
assert (
entity.window_manager._window_auto_algo.is_window_open_detected() is False
)
assert (
entity.window_manager._window_auto_algo.is_window_close_detected() is False
)
assert entity.hvac_mode is HVACMode.HEAT
# send one degre down in one minute
@@ -361,8 +365,10 @@ async def test_window_auto_fast(hass: HomeAssistant, skip_hass_states_is_state):
assert mock_heater_on.call_count == 0
assert mock_heater_off.call_count >= 1
assert entity.last_temperature_slope == -6.24
assert entity._window_auto_algo.is_window_open_detected() is True
assert entity._window_auto_algo.is_window_close_detected() is False
assert entity.window_manager._window_auto_algo.is_window_open_detected() is True
assert (
entity.window_manager._window_auto_algo.is_window_close_detected() is False
)
assert entity.window_auto_state == STATE_ON
assert entity.hvac_mode is HVACMode.OFF
@@ -397,8 +403,10 @@ async def test_window_auto_fast(hass: HomeAssistant, skip_hass_states_is_state):
assert mock_heater_on.call_count == 0
assert mock_heater_off.call_count == 0
assert round(entity.last_temperature_slope, 3) == -7.49
assert entity._window_auto_algo.is_window_open_detected() is True
assert entity._window_auto_algo.is_window_close_detected() is False
assert entity.window_manager._window_auto_algo.is_window_open_detected() is True
assert (
entity.window_manager._window_auto_algo.is_window_close_detected() is False
)
assert entity.window_auto_state == STATE_ON
assert entity.hvac_mode is HVACMode.OFF
@@ -438,8 +446,12 @@ async def test_window_auto_fast(hass: HomeAssistant, skip_hass_states_is_state):
assert mock_heater_on.call_count == 1
assert mock_heater_off.call_count == 0
assert entity.last_temperature_slope == 0.42
assert entity._window_auto_algo.is_window_open_detected() is False
assert entity._window_auto_algo.is_window_close_detected() is True
assert (
entity.window_manager._window_auto_algo.is_window_open_detected() is False
)
assert (
entity.window_manager._window_auto_algo.is_window_close_detected() is True
)
assert entity.window_auto_state == STATE_OFF
assert entity.hvac_mode is HVACMode.HEAT
@@ -478,9 +490,10 @@ async def test_window_auto_fast_and_sensor(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_SENSOR: "binary_sensor.fake_window_sensor",
CONF_WINDOW_DELAY: 10,
CONF_WINDOW_AUTO_OPEN_THRESHOLD: 0.1,
CONF_WINDOW_AUTO_CLOSE_THRESHOLD: 0.1,
CONF_WINDOW_AUTO_MAX_DURATION: 10, # Should be 0 for test
@@ -504,8 +517,10 @@ async def test_window_auto_fast_and_sensor(
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 21
assert entity.window_state is STATE_OFF
assert entity.is_window_auto_enabled is False
assert entity.window_state is STATE_UNKNOWN
assert entity.window_auto_state is STATE_UNAVAILABLE
assert entity.window_manager.is_window_auto_configured is False
assert entity.window_manager.is_configured is True
# Initialize the slope algo with 2 measurements
event_timestamp = now + timedelta(minutes=1)
@@ -534,8 +549,12 @@ async def test_window_auto_fast_and_sensor(
assert mock_send_event.call_count == 0
assert entity.is_device_active is True
assert entity.last_temperature_slope == 0.0
assert entity._window_auto_algo.is_window_open_detected() is False
assert entity._window_auto_algo.is_window_close_detected() is False
assert (
entity.window_manager._window_auto_algo.is_window_open_detected() is False
)
assert (
entity.window_manager._window_auto_algo.is_window_close_detected() is False
)
assert entity.hvac_mode is HVACMode.HEAT
# send one degre down in one minute
@@ -559,9 +578,11 @@ async def test_window_auto_fast_and_sensor(
assert entity.last_temperature_slope == -6.24
# The window open should be detected (but not used)
# because we need to calculate the slope anyway, we have the algorithm running
assert entity._window_auto_algo.is_window_open_detected() is True
assert entity._window_auto_algo.is_window_close_detected() is False
assert entity.window_auto_state == STATE_OFF
assert entity.window_manager._window_auto_algo.is_window_open_detected() is True
assert (
entity.window_manager._window_auto_algo.is_window_close_detected() is False
)
assert entity.window_auto_state == STATE_UNAVAILABLE
assert entity.hvac_mode is HVACMode.HEAT
# Clean the entity
@@ -594,8 +615,8 @@ async def test_window_auto_auto_stop(hass: HomeAssistant, skip_hass_states_is_st
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "switch.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_AUTO_OPEN_THRESHOLD: 6,
CONF_WINDOW_AUTO_CLOSE_THRESHOLD: 6,
CONF_WINDOW_AUTO_MAX_DURATION: 1, # 0 will deactivate window auto detection
@@ -617,11 +638,11 @@ async def test_window_auto_auto_stop(hass: HomeAssistant, skip_hass_states_is_st
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNAVAILABLE
assert entity.target_temperature == 21
assert entity.window_state is STATE_OFF
assert entity.is_window_auto_enabled is True
assert entity.window_state is STATE_UNKNOWN
assert entity.window_manager.is_window_auto_configured is True
# 1. Initialize the slope algo with 2 measurements
event_timestamp = now + timedelta(minutes=1)
@@ -647,8 +668,12 @@ async def test_window_auto_auto_stop(hass: HomeAssistant, skip_hass_states_is_st
# The climate turns on but was alredy on
assert mock_set_hvac_mode.call_count == 0
assert entity.last_temperature_slope == 0.0
assert entity._window_auto_algo.is_window_open_detected() is False
assert entity._window_auto_algo.is_window_close_detected() is False
assert (
entity.window_manager._window_auto_algo.is_window_open_detected() is False
)
assert (
entity.window_manager._window_auto_algo.is_window_close_detected() is False
)
assert entity.hvac_mode is HVACMode.HEAT
# 3. send one degre down in one minute
@@ -665,8 +690,10 @@ async def test_window_auto_auto_stop(hass: HomeAssistant, skip_hass_states_is_st
await send_temperature_change_event(entity, 18, event_timestamp, sleep=False)
assert entity.last_temperature_slope == -6.24
assert entity._window_auto_algo.is_window_open_detected() is True
assert entity._window_auto_algo.is_window_close_detected() is False
assert entity.window_manager._window_auto_algo.is_window_open_detected() is True
assert (
entity.window_manager._window_auto_algo.is_window_close_detected() is False
)
assert mock_send_event.call_count == 2
# The heater turns off
@@ -714,8 +741,12 @@ async def test_window_auto_auto_stop(hass: HomeAssistant, skip_hass_states_is_st
assert mock_set_hvac_mode.call_count == 1
assert round(entity.last_temperature_slope, 3) == -0.29
assert entity._window_auto_algo.is_window_open_detected() is False
assert entity._window_auto_algo.is_window_close_detected() is False
assert (
entity.window_manager._window_auto_algo.is_window_open_detected() is False
)
assert (
entity.window_manager._window_auto_algo.is_window_close_detected() is False
)
# Clean the entity
entity.remove_thermostat()
@@ -752,11 +783,11 @@ async def test_window_auto_no_on_percent(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_AUTO_OPEN_THRESHOLD: 6,
CONF_WINDOW_AUTO_CLOSE_THRESHOLD: 6,
CONF_WINDOW_AUTO_MAX_DURATION: 0, # Should be 0 for test
CONF_WINDOW_AUTO_MAX_DURATION: 1, # Should be 0 for test but 0 is not possible
},
)
@@ -775,10 +806,11 @@ async def test_window_auto_no_on_percent(
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNAVAILABLE
assert entity.target_temperature == 20
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNKNOWN
assert entity.window_auto_state is STATE_UNKNOWN
# Initialize the slope algo with 2 measurements
event_timestamp = now + timedelta(minutes=1)
@@ -806,8 +838,12 @@ async def test_window_auto_no_on_percent(
# The heater don't turns on
assert mock_heater_on.call_count == 0
assert entity.last_temperature_slope == 0.0
assert entity._window_auto_algo.is_window_open_detected() is False
assert entity._window_auto_algo.is_window_close_detected() is False
assert (
entity.window_manager._window_auto_algo.is_window_open_detected() is False
)
assert (
entity.window_manager._window_auto_algo.is_window_close_detected() is False
)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.proportional_algorithm.on_percent == 0.0
@@ -833,10 +869,12 @@ async def test_window_auto_no_on_percent(
assert mock_heater_off.call_count == 1
assert entity.last_temperature_slope == -6.24
# The algo calculate open ...
assert entity._window_auto_algo.is_window_open_detected() is True
assert entity._window_auto_algo.is_window_close_detected() is False
# But the entity is still on
assert entity.window_auto_state == STATE_OFF
assert entity.window_manager._window_auto_algo.is_window_open_detected() is True
assert (
entity.window_manager._window_auto_algo.is_window_close_detected() is False
)
# But the entity is still on and window_auto is not detected
assert entity.window_auto_state == STATE_UNKNOWN
assert entity.hvac_mode is HVACMode.HEAT
# Clean the entity
@@ -872,8 +910,8 @@ async def test_window_bypass(hass: HomeAssistant, skip_hass_states_is_state):
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_SENSOR: "binary_sensor.mock_window_sensor",
CONF_WINDOW_DELAY: 0, # important to not been obliged to wait
},
@@ -891,11 +929,11 @@ async def test_window_bypass(hass: HomeAssistant, skip_hass_states_is_state):
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNAVAILABLE
assert entity.target_temperature == 19
assert entity.window_state is STATE_OFF
assert entity.is_window_auto_enabled is False
assert entity.window_state is STATE_UNKNOWN
assert entity.window_manager.is_window_auto_configured is False
# change temperature to force turning on the heater
with patch(
@@ -918,9 +956,7 @@ async def test_window_bypass(hass: HomeAssistant, skip_hass_states_is_state):
# Set Window ByPass to true
await entity.service_set_window_bypass_state(True)
assert entity.window_bypass_state is True
# entity._window_bypass_state = True
assert entity.is_window_bypass is True
# Open the window, condition of time is satisfied, check the thermostat and heater turns off
with patch(
@@ -936,7 +972,10 @@ async def test_window_bypass(hass: HomeAssistant, skip_hass_states_is_state):
new_callable=PropertyMock,
return_value=True,
):
await send_window_change_event(entity, True, False, datetime.now())
try_function = await send_window_change_event(
entity, True, False, datetime.now()
)
await try_function(None)
assert mock_send_event.call_count == 0
@@ -944,7 +983,7 @@ async def test_window_bypass(hass: HomeAssistant, skip_hass_states_is_state):
assert mock_heater_on.call_count == 0
# One call in set_hvac_mode turn_off and one call in the control_heating for security
assert mock_heater_off.call_count == 0
assert mock_condition.call_count == 1
assert mock_condition.call_count > 0
assert entity.hvac_mode is HVACMode.HEAT
assert entity.window_state == STATE_ON
@@ -1011,8 +1050,8 @@ async def test_window_auto_bypass(hass: HomeAssistant, skip_hass_states_is_state
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_AUTO_OPEN_THRESHOLD: 6,
CONF_WINDOW_AUTO_CLOSE_THRESHOLD: 6,
CONF_WINDOW_AUTO_MAX_DURATION: 1, # Should be > 0 to activate window_auto
@@ -1034,11 +1073,11 @@ async def test_window_auto_bypass(hass: HomeAssistant, skip_hass_states_is_state
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNAVAILABLE
assert entity.target_temperature == 21
assert entity.window_state is STATE_OFF
assert entity.is_window_auto_enabled
assert entity.window_state is STATE_UNKNOWN
assert entity.window_manager.is_window_auto_configured
# Initialize the slope algo with 2 measurements
event_timestamp = now + timedelta(minutes=1)
@@ -1066,13 +1105,17 @@ async def test_window_auto_bypass(hass: HomeAssistant, skip_hass_states_is_state
# The heater turns on
assert entity.is_device_active is True
assert entity.last_temperature_slope == 0.0
assert entity._window_auto_algo.is_window_open_detected() is False
assert entity._window_auto_algo.is_window_close_detected() is False
assert (
entity.window_manager._window_auto_algo.is_window_open_detected() is False
)
assert (
entity.window_manager._window_auto_algo.is_window_close_detected() is False
)
assert entity.hvac_mode is HVACMode.HEAT
# send one degre down in one minute with window bypass on
await entity.service_set_window_bypass_state(True)
assert entity.window_bypass_state is True
assert entity.is_window_bypass is True
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
@@ -1094,9 +1137,11 @@ async def test_window_auto_bypass(hass: HomeAssistant, skip_hass_states_is_state
assert mock_heater_on.call_count == 0
assert mock_heater_off.call_count == 0
assert entity.last_temperature_slope == -6.24
assert entity._window_auto_algo.is_window_open_detected() is True
assert entity._window_auto_algo.is_window_close_detected() is False
assert entity.window_auto_state == STATE_OFF
assert entity.window_manager._window_auto_algo.is_window_open_detected() is True
assert (
entity.window_manager._window_auto_algo.is_window_close_detected() is False
)
assert entity.window_auto_state == STATE_UNKNOWN
assert entity.hvac_mode is HVACMode.HEAT
# Clean the entity
@@ -1133,8 +1178,8 @@ async def test_window_bypass_reactivate(hass: HomeAssistant, skip_hass_states_is
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_SENSOR: "binary_sensor.mock_window_sensor",
CONF_WINDOW_DELAY: 0, # important to not been obliged to wait
},
@@ -1152,10 +1197,10 @@ async def test_window_bypass_reactivate(hass: HomeAssistant, skip_hass_states_is
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNAVAILABLE
assert entity.target_temperature == 19
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNKNOWN
# change temperature to force turning on the heater
with patch(
@@ -1262,8 +1307,8 @@ async def test_window_action_fan_only(hass: HomeAssistant, skip_hass_states_is_s
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_SENSOR: "binary_sensor.mock_window_sensor",
CONF_WINDOW_DELAY: 1,
CONF_WINDOW_ACTION: CONF_WINDOW_FAN_ONLY,
@@ -1299,7 +1344,7 @@ async def test_window_action_fan_only(hass: HomeAssistant, skip_hass_states_is_s
assert entity
assert entity.is_over_climate is True
assert entity.window_action == CONF_WINDOW_FAN_ONLY
assert entity.window_manager.window_action == CONF_WINDOW_FAN_ONLY
await entity.async_set_hvac_mode(HVACMode.HEAT)
assert entity.hvac_mode == HVACMode.HEAT
@@ -1307,7 +1352,7 @@ async def test_window_action_fan_only(hass: HomeAssistant, skip_hass_states_is_s
assert entity.preset_mode == PRESET_COMFORT
assert entity.target_temperature == 18
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNKNOWN
# 2. Open the window, condition of time is satisfied, check the thermostat and heater turns off
with patch(
@@ -1419,8 +1464,8 @@ async def test_window_action_fan_only_ko(
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_SENSOR: "binary_sensor.mock_window_sensor",
CONF_WINDOW_DELAY: 1,
CONF_WINDOW_ACTION: CONF_WINDOW_FAN_ONLY,
@@ -1456,7 +1501,7 @@ async def test_window_action_fan_only_ko(
assert entity
assert entity.is_over_climate is True
assert entity.window_action == CONF_WINDOW_FAN_ONLY
assert entity.window_manager.window_action == CONF_WINDOW_FAN_ONLY
await entity.async_set_hvac_mode(HVACMode.HEAT)
assert entity.hvac_mode == HVACMode.HEAT
@@ -1464,7 +1509,7 @@ async def test_window_action_fan_only_ko(
assert entity.preset_mode == PRESET_COMFORT
assert entity.target_temperature == 18
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNKNOWN
# 2. Open the window, condition of time is satisfied, check the thermostat and heater turns off
with patch(
@@ -1570,8 +1615,8 @@ async def test_window_action_eco_temp(hass: HomeAssistant, skip_hass_states_is_s
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_AUTO_OPEN_THRESHOLD: 0.1,
CONF_WINDOW_AUTO_CLOSE_THRESHOLD: 0.1,
CONF_WINDOW_AUTO_MAX_DURATION: 10, # Should be 0 for test
@@ -1591,11 +1636,11 @@ async def test_window_action_eco_temp(hass: HomeAssistant, skip_hass_states_is_s
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNAVAILABLE
assert entity.target_temperature == 21
assert entity.window_state is STATE_OFF
assert entity.is_window_auto_enabled is True
assert entity.window_state is STATE_UNKNOWN
assert entity.window_manager.is_window_auto_configured is True
# 1. Initialize the slope algo with 2 measurements
event_timestamp = now + timedelta(minutes=1)
@@ -1624,8 +1669,8 @@ async def test_window_action_eco_temp(hass: HomeAssistant, skip_hass_states_is_s
assert mock_send_event.call_count == 0
assert entity.is_device_active is True
assert entity.hvac_mode is HVACMode.HEAT
assert entity.window_state is STATE_OFF
assert entity.window_auto_state is STATE_OFF
assert entity.window_state is STATE_UNKNOWN
assert entity.window_auto_state is STATE_UNKNOWN
# 3. send one degre down in one minute
with patch(
@@ -1648,7 +1693,7 @@ async def test_window_action_eco_temp(hass: HomeAssistant, skip_hass_states_is_s
assert mock_heater_off.call_count == 0
assert entity.last_temperature_slope == -6.24
assert entity.window_auto_state == STATE_ON
assert entity.window_state == STATE_OFF
assert entity.window_state == STATE_ON
# No change on HVACMode
assert entity.hvac_mode is HVACMode.HEAT
# No change on preset
@@ -1762,13 +1807,13 @@ async def test_window_action_frost_temp(hass: HomeAssistant, skip_hass_states_is
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_HEATER: "switch.mock_switch",
CONF_UNDERLYING_LIST: ["switch.mock_switch"],
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_AUTO_OPEN_THRESHOLD: 0.1,
CONF_WINDOW_AUTO_CLOSE_THRESHOLD: 0.1,
CONF_WINDOW_AUTO_MAX_DURATION: 10, # Should be 0 for test
@@ -1788,11 +1833,11 @@ async def test_window_action_frost_temp(hass: HomeAssistant, skip_hass_states_is
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.power_manager.overpowering_state is STATE_UNAVAILABLE
assert entity.target_temperature == 21
assert entity.window_state is STATE_OFF
assert entity.is_window_auto_enabled is True
assert entity.window_state is STATE_UNKNOWN
assert entity.window_manager.is_window_auto_configured is True
# 1. Initialize the slope algo with 2 measurements
event_timestamp = now + timedelta(minutes=1)
@@ -1802,7 +1847,7 @@ async def test_window_action_frost_temp(hass: HomeAssistant, skip_hass_states_is
event_timestamp = event_timestamp + timedelta(minutes=1)
await send_temperature_change_event(entity, 19, event_timestamp)
# 2. Make the temperature down -> no change
# 2. Make the temperature down
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
@@ -1821,10 +1866,10 @@ async def test_window_action_frost_temp(hass: HomeAssistant, skip_hass_states_is
assert mock_send_event.call_count == 0
assert entity.is_device_active is True
assert entity.hvac_mode is HVACMode.HEAT
assert entity.window_state is STATE_OFF
assert entity.window_auto_state is STATE_OFF
assert entity.window_state is STATE_UNKNOWN
assert entity.window_auto_state is STATE_UNKNOWN
# 3. send one degre down in one minute -> window is on
# 3. send one degre down in one minute
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
@@ -1845,15 +1890,13 @@ async def test_window_action_frost_temp(hass: HomeAssistant, skip_hass_states_is
assert mock_heater_off.call_count == 0
assert entity.last_temperature_slope == -6.24
assert entity.window_auto_state == STATE_ON
assert entity.window_state == STATE_OFF
assert entity.window_state == STATE_ON
# No change on HVACMode
assert entity.hvac_mode is HVACMode.HEAT
# No change on preset
assert entity.preset_mode is PRESET_BOOST
# The eco temp
assert entity.target_temperature == 10
# The last temp is saved
assert entity._saved_target_temp == 21
mock_send_event.assert_has_calls(
[
@@ -1891,7 +1934,6 @@ async def test_window_action_frost_temp(hass: HomeAssistant, skip_hass_states_is
assert entity.preset_mode is PRESET_BOOST
# The eco temp
assert entity.target_temperature == 10
assert entity._saved_target_temp == 21
# 5. send another plus 1.1 degre in one minute -> restore state
with patch(
@@ -1930,9 +1972,8 @@ async def test_window_action_frost_temp(hass: HomeAssistant, skip_hass_states_is
assert entity.hvac_mode is HVACMode.HEAT
# No change on preset
assert entity.preset_mode is PRESET_BOOST
# The eco temp
# The Boost temp
assert entity.target_temperature == 21
assert entity._saved_target_temp == 21
# Clean the entity
entity.remove_thermostat()
@@ -1975,9 +2016,9 @@ async def test_bug_66(
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1, # !! here
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.5,
CONF_SAFETY_DEFAULT_ON_PERCENT: 0.1, # !! here
CONF_DEVICE_POWER: 200,
CONF_WINDOW_SENSOR: "binary_sensor.mock_window_sensor",
CONF_WINDOW_DELAY: 0, # important to not been obliged to wait
@@ -1995,7 +2036,7 @@ async def test_bug_66(
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 19
assert entity.window_state is STATE_OFF
assert entity.window_state is STATE_UNKNOWN
# Open the window and let the thermostat shut down
with patch(
@@ -2095,3 +2136,223 @@ async def test_bug_66(
assert entity.window_state == STATE_OFF
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_window_action_frost_temp_preset_change(
hass: HomeAssistant, skip_hass_states_is_state
):
"""Test the Window management with the frost_temp option and change the preset during
the window is open. This should restore the new preset temperature"""
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverSwitchMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverSwitchMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_SWITCH,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
CONF_USE_WINDOW_FEATURE: True,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_UNDERLYING_LIST: ["switch.mock_switch"],
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_ACTION: CONF_WINDOW_FROST_TEMP,
CONF_WINDOW_SENSOR: "binary_sensor.fake_window_sensor",
CONF_WINDOW_DELAY: 1,
},
)
vtherm: BaseThermostat = await create_thermostat(
hass, entry, "climate.theoverswitchmockname"
)
assert vtherm
await set_all_climate_preset_temp(
hass, vtherm, default_temperatures, "theoverswitchmockname"
)
tz = get_tz(hass) # pylint: disable=invalid-name
now = datetime.now(tz)
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
await vtherm.async_set_preset_mode(PRESET_BOOST)
await hass.async_block_till_done()
assert vtherm.hvac_mode is HVACMode.HEAT
assert vtherm.preset_mode is PRESET_BOOST
assert vtherm.target_temperature == 21
assert vtherm.window_state is STATE_UNKNOWN
assert vtherm.window_manager.is_window_auto_configured is False
# 1. Turn on the window sensor
now = now + timedelta(minutes=1)
vtherm._set_now(now)
with patch("homeassistant.helpers.condition.state", return_value=True):
try_function = await send_window_change_event(vtherm, True, False, now)
now = now + timedelta(minutes=2)
vtherm._set_now(now)
await try_function(None)
# VTherm should have taken the window action
assert vtherm.target_temperature == 7 # Frost
# No change
assert vtherm.preset_mode is PRESET_BOOST
assert vtherm.hvac_mode is HVACMode.HEAT
# 2. Change the preset to comfort
now = now + timedelta(minutes=1)
vtherm._set_now(now)
await vtherm.async_set_preset_mode(PRESET_COMFORT)
await hass.async_block_till_done()
# VTherm should have taken the new preset temperature
assert vtherm.target_temperature == 7 # frost (window is still open)
assert vtherm.preset_mode is PRESET_COMFORT
assert vtherm.hvac_mode is HVACMode.HEAT
# 3.Turn off the window sensor
now = now + timedelta(minutes=1)
vtherm._set_now(now)
with patch("homeassistant.helpers.condition.state", return_value=True):
try_function = await send_window_change_event(vtherm, False, True, now)
now = now + timedelta(minutes=2)
vtherm._set_now(now)
await try_function(None)
# VTherm should have restore the Comfort preset temperature
assert vtherm.target_temperature == 19 # restore comfort
# No change
assert vtherm.preset_mode is PRESET_COMFORT
assert vtherm.hvac_mode is HVACMode.HEAT
# Clean the entity
vtherm.remove_thermostat()
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_window_action_frost_temp_temp_change(
hass: HomeAssistant, skip_hass_states_is_state
):
"""Test the Window management with the frost_temp option and change the target temp during
the window is open. This should restore the new temperature"""
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverSwitchMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverSwitchMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_SWITCH,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
CONF_USE_WINDOW_FEATURE: True,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_UNDERLYING_LIST: ["switch.mock_switch"],
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SAFETY_DELAY_MIN: 5,
CONF_SAFETY_MIN_ON_PERCENT: 0.3,
CONF_WINDOW_ACTION: CONF_WINDOW_FROST_TEMP,
CONF_WINDOW_SENSOR: "binary_sensor.fake_window_sensor",
CONF_WINDOW_DELAY: 1,
},
)
vtherm: BaseThermostat = await create_thermostat(
hass, entry, "climate.theoverswitchmockname"
)
assert vtherm
await set_all_climate_preset_temp(
hass, vtherm, default_temperatures, "theoverswitchmockname"
)
tz = get_tz(hass) # pylint: disable=invalid-name
now = datetime.now(tz)
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
await vtherm.async_set_preset_mode(PRESET_BOOST)
await hass.async_block_till_done()
assert vtherm.hvac_mode is HVACMode.HEAT
assert vtherm.preset_mode is PRESET_BOOST
assert vtherm.target_temperature == 21
assert vtherm.window_state is STATE_UNKNOWN
assert vtherm.window_manager.is_window_auto_configured is False
# 1. Turn on the window sensor
now = now + timedelta(minutes=1)
vtherm._set_now(now)
with patch("homeassistant.helpers.condition.state", return_value=True):
try_function = await send_window_change_event(vtherm, True, False, now)
now = now + timedelta(minutes=2)
vtherm._set_now(now)
await try_function(None)
# VTherm should have taken the window action
assert vtherm.target_temperature == 7 # Frost
# No change
assert vtherm.preset_mode is PRESET_BOOST
assert vtherm.hvac_mode is HVACMode.HEAT
# 2. Change the target temperature
now = now + timedelta(minutes=1)
vtherm._set_now(now)
await vtherm.async_set_temperature(temperature=18.5)
await hass.async_block_till_done()
# VTherm should have taken the new preset temperature
assert vtherm.target_temperature == 7 # frost (window is still open)
assert vtherm.preset_mode is PRESET_NONE
assert vtherm.hvac_mode is HVACMode.HEAT
# 3.Turn off the window sensor
now = now + timedelta(minutes=1)
vtherm._set_now(now)
with patch("homeassistant.helpers.condition.state", return_value=True):
try_function = await send_window_change_event(vtherm, False, True, now)
now = now + timedelta(minutes=2)
vtherm._set_now(now)
await try_function(None)
# VTherm should have restore the new target temperature
assert vtherm.target_temperature == 18.5 # restore new target temperature
# No change
assert vtherm.preset_mode is PRESET_NONE
assert vtherm.hvac_mode is HVACMode.HEAT
# Clean the entity
vtherm.remove_thermostat()

View File

@@ -0,0 +1,706 @@
# pylint: disable=unused-argument, line-too-long, protected-access, too-many-lines
""" Test the Window management """
import logging
from datetime import datetime, timedelta
from unittest.mock import patch, call, PropertyMock, AsyncMock, MagicMock
from custom_components.versatile_thermostat.base_thermostat import BaseThermostat
from custom_components.versatile_thermostat.feature_window_manager import (
FeatureWindowManager,
)
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
logging.getLogger().setLevel(logging.DEBUG)
async def test_window_feature_manager_create(
hass: HomeAssistant,
):
"""Test the FeatureMotionManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
# 1. creation
window_manager = FeatureWindowManager(fake_vtherm, hass)
assert window_manager is not None
assert window_manager.is_configured is False
assert window_manager.is_window_auto_configured is False
assert window_manager.is_window_detected is False
assert window_manager.window_state == STATE_UNAVAILABLE
assert window_manager.name == "the name"
assert len(window_manager._active_listener) == 0
custom_attributes = {}
window_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["window_sensor_entity_id"] is None
assert custom_attributes["window_state"] == STATE_UNAVAILABLE
assert custom_attributes["window_auto_state"] == STATE_UNAVAILABLE
assert custom_attributes["is_window_configured"] is False
assert custom_attributes["is_window_auto_configured"] is False
assert custom_attributes["window_delay_sec"] == 0
assert custom_attributes["window_auto_open_threshold"] == 0
assert custom_attributes["window_auto_close_threshold"] == 0
assert custom_attributes["window_auto_max_duration"] == 0
assert custom_attributes["window_action"] is None
@pytest.mark.parametrize(
"use_window_feature, window_sensor_entity_id, window_delay_sec, window_auto_open_threshold, window_auto_close_threshold, window_auto_max_duration, window_action, is_configured, is_auto_configured, window_state, window_auto_state",
[
# fmt: off
( True, "sensor.the_window_sensor", 10, None, None, None, CONF_WINDOW_TURN_OFF, True, False, STATE_UNKNOWN, STATE_UNAVAILABLE ),
( False, "sensor.the_window_sensor", 10, None, None, None, CONF_WINDOW_FAN_ONLY, False, False, STATE_UNAVAILABLE, STATE_UNAVAILABLE ),
( True, "sensor.the_window_sensor", 10, None, None, None, CONF_WINDOW_FROST_TEMP, True, False, STATE_UNKNOWN, STATE_UNAVAILABLE ),
# delay is missing
( True, "sensor.the_window_sensor", None, None, None, None, CONF_WINDOW_ECO_TEMP, False, False, STATE_UNAVAILABLE, STATE_UNAVAILABLE ),
# action is missing -> defaults to TURN_OFF
( True, "sensor.the_window_sensor", 10, None, None, None, None, True, False, STATE_UNKNOWN, STATE_UNAVAILABLE ),
# With Window auto config complete
( True, None, None, 1, 2, 3, CONF_WINDOW_FAN_ONLY, True, True, STATE_UNKNOWN, STATE_UNKNOWN ),
# With Window auto config not complete -> missing open threshold but defaults to 0
( True, None, None, None, 2, 3, CONF_WINDOW_FROST_TEMP, False, False, STATE_UNAVAILABLE, STATE_UNAVAILABLE ),
# With Window auto config not complete -> missing close threshold
( True, None, None, 1, None, 3, CONF_WINDOW_ECO_TEMP, False, False, STATE_UNAVAILABLE, STATE_UNAVAILABLE ),
# With Window auto config not complete -> missing max duration threshold but defaults to 0
( True, None, None, 1, 2, None, CONF_WINDOW_TURN_OFF, False, False, STATE_UNAVAILABLE, STATE_UNAVAILABLE ),
# fmt: on
],
)
async def test_window_feature_manager_post_init(
hass: HomeAssistant,
use_window_feature,
window_sensor_entity_id,
window_delay_sec,
window_auto_open_threshold,
window_auto_close_threshold,
window_auto_max_duration,
window_action,
is_configured,
is_auto_configured,
window_state,
window_auto_state,
):
"""Test the FeatureMotionManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
# 1. creation
window_manager = FeatureWindowManager(fake_vtherm, hass)
assert window_manager is not None
# 2. post_init
window_manager.post_init(
{
CONF_USE_WINDOW_FEATURE: use_window_feature,
CONF_WINDOW_SENSOR: window_sensor_entity_id,
CONF_WINDOW_DELAY: window_delay_sec,
CONF_WINDOW_AUTO_OPEN_THRESHOLD: window_auto_open_threshold,
CONF_WINDOW_AUTO_CLOSE_THRESHOLD: window_auto_close_threshold,
CONF_WINDOW_AUTO_MAX_DURATION: window_auto_max_duration,
CONF_WINDOW_ACTION: window_action,
}
)
assert window_manager.is_configured is is_configured
assert window_manager.is_window_auto_configured == is_auto_configured
assert window_manager.window_sensor_entity_id == window_sensor_entity_id
assert window_manager.window_state == window_state
assert window_manager.window_auto_state == window_auto_state
assert window_manager.window_delay_sec == window_delay_sec
assert window_manager.window_auto_open_threshold == window_auto_open_threshold
assert window_manager.window_auto_close_threshold == window_auto_close_threshold
custom_attributes = {}
window_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["window_sensor_entity_id"] == window_sensor_entity_id
assert custom_attributes["window_state"] == window_state
assert custom_attributes["window_auto_state"] == window_auto_state
assert custom_attributes["is_window_bypass"] is False
assert custom_attributes["is_window_configured"] is is_configured
assert custom_attributes["is_window_auto_configured"] is is_auto_configured
assert custom_attributes["is_window_bypass"] is False
assert custom_attributes["window_delay_sec"] is window_delay_sec
assert custom_attributes["window_auto_open_threshold"] is window_auto_open_threshold
assert (
custom_attributes["window_auto_close_threshold"] is window_auto_close_threshold
)
assert custom_attributes["window_auto_max_duration"] is window_auto_max_duration
@pytest.mark.parametrize(
"current_state, new_state, nb_call, window_state, is_window_detected, changed",
[
(STATE_OFF, STATE_ON, 1, STATE_ON, True, True),
(STATE_OFF, STATE_OFF, 0, STATE_OFF, False, False),
(STATE_ON, STATE_OFF, 1, STATE_OFF, False, True),
(STATE_ON, STATE_ON, 0, STATE_ON, True, False),
],
)
async def test_window_feature_manager_refresh_sensor_action_turn_off(
hass: HomeAssistant,
current_state,
new_state, # new state of motion event
nb_call,
window_state,
is_window_detected,
changed,
):
"""Test the FeatureMotionManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
type(fake_vtherm).preset_mode = PropertyMock(return_value=PRESET_COMFORT)
# 1. creation
window_manager = FeatureWindowManager(fake_vtherm, hass)
# 2. post_init
window_manager.post_init(
{
CONF_WINDOW_SENSOR: "sensor.the_window_sensor",
CONF_USE_WINDOW_FEATURE: True,
CONF_WINDOW_DELAY: 10,
CONF_WINDOW_ACTION: CONF_WINDOW_TURN_OFF,
}
)
# 3. start listening
window_manager.start_listening()
assert window_manager.is_configured is True
assert window_manager.window_state == STATE_UNKNOWN
assert window_manager.window_auto_state == STATE_UNAVAILABLE
assert len(window_manager._active_listener) == 1
# 4. test refresh with the parametrized
# fmt:off
with patch("homeassistant.core.StateMachine.get", return_value=State("sensor.the_motion_sensor", new_state)) as mock_get_state:
# fmt:on
# Configurer les méthodes mockées
fake_vtherm.async_set_hvac_mode = AsyncMock()
fake_vtherm.set_hvac_off_reason = MagicMock()
fake_vtherm.restore_hvac_mode = AsyncMock()
# force old state for the test
window_manager._window_state = current_state
if current_state == STATE_ON:
type(fake_vtherm).hvac_off_reason = PropertyMock(return_value=HVAC_OFF_REASON_WINDOW_DETECTION)
else:
type(fake_vtherm).hvac_off_reason = PropertyMock(return_value=None)
ret = await window_manager.refresh_state()
assert ret == changed
assert window_manager.is_configured is True
# in the refresh there is no delay
assert window_manager.window_state == new_state
assert mock_get_state.call_count == 1
assert fake_vtherm.set_hvac_off_reason.call_count == nb_call
if nb_call == 1:
if new_state == STATE_OFF:
assert fake_vtherm.restore_hvac_mode.call_count == 1
assert fake_vtherm.async_set_hvac_mode.call_count == 0
else:
assert fake_vtherm.async_set_hvac_mode.call_count == 1
fake_vtherm.async_set_hvac_mode.assert_has_calls(
[
call.async_set_hvac_mode(HVACMode.OFF),
]
)
assert fake_vtherm.restore_hvac_mode.call_count == 0
reason = None if current_state == STATE_ON and new_state == STATE_OFF else HVAC_OFF_REASON_WINDOW_DETECTION
fake_vtherm.set_hvac_off_reason.assert_has_calls(
[
call.set_hvac_off_reason(reason),
]
)
else:
assert fake_vtherm.restore_hvac_mode.call_count == 0
assert fake_vtherm.async_set_hvac_mode.call_count == 0
fake_vtherm.reset_mock()
# 5. Check custom_attributes
custom_attributes = {}
window_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["window_sensor_entity_id"] == "sensor.the_window_sensor"
assert custom_attributes["window_state"] == new_state
assert custom_attributes["window_auto_state"] == STATE_UNAVAILABLE
assert custom_attributes["is_window_bypass"] is False
assert custom_attributes["is_window_configured"] is True
assert custom_attributes["is_window_auto_configured"] is False
assert custom_attributes["is_window_bypass"] is False
assert custom_attributes["window_delay_sec"] is 10
assert custom_attributes["window_auto_open_threshold"] is None
assert (
custom_attributes["window_auto_close_threshold"] is None
)
assert custom_attributes["window_auto_max_duration"] is None
window_manager.stop_listening()
await hass.async_block_till_done()
@pytest.mark.parametrize(
"current_state, new_state, nb_call, window_state, is_window_detected, changed",
[
(STATE_OFF, STATE_ON, 1, STATE_ON, True, True),
(STATE_OFF, STATE_OFF, 0, STATE_OFF, False, False),
(STATE_ON, STATE_OFF, 1, STATE_OFF, False, True),
(STATE_ON, STATE_ON, 0, STATE_ON, True, False),
],
)
async def test_window_feature_manager_refresh_sensor_action_frost_only(
hass: HomeAssistant,
current_state,
new_state, # new state of motion event
nb_call,
window_state,
is_window_detected,
changed,
):
"""Test the FeatureMotionManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
type(fake_vtherm).preset_mode = PropertyMock(return_value=PRESET_COMFORT)
type(fake_vtherm).last_central_mode = PropertyMock(return_value=None)
# 1. creation
window_manager = FeatureWindowManager(fake_vtherm, hass)
# 2. post_init
window_manager.post_init(
{
CONF_WINDOW_SENSOR: "sensor.the_window_sensor",
CONF_USE_WINDOW_FEATURE: True,
CONF_WINDOW_DELAY: 10,
CONF_WINDOW_ACTION: CONF_WINDOW_FROST_TEMP,
}
)
# 3. start listening
window_manager.start_listening()
assert window_manager.is_configured is True
assert window_manager.window_state == STATE_UNKNOWN
assert window_manager.window_auto_state == STATE_UNAVAILABLE
assert len(window_manager._active_listener) == 1
# 4. test refresh with the parametrized
# fmt:off
with patch("homeassistant.core.StateMachine.get", return_value=State("sensor.the_motion_sensor", new_state)) as mock_get_state:
# fmt:on
# Configurer les méthodes mockées
fake_vtherm.save_target_temp = AsyncMock()
fake_vtherm.set_hvac_off_reason = MagicMock()
fake_vtherm.restore_target_temp = AsyncMock()
fake_vtherm.change_target_temperature = AsyncMock()
fake_vtherm.find_preset_temp = MagicMock()
fake_vtherm.find_preset_temp.return_value = 17
# force old state for the test
window_manager._window_state = current_state
if current_state == STATE_ON:
type(fake_vtherm).hvac_off_reason = PropertyMock(return_value=HVAC_OFF_REASON_WINDOW_DETECTION)
else:
type(fake_vtherm).hvac_off_reason = PropertyMock(return_value=None)
ret = await window_manager.refresh_state()
assert ret == changed
assert window_manager.is_configured is True
# in the refresh there is no delay
assert window_manager.window_state == new_state
assert mock_get_state.call_count == 1
assert fake_vtherm.set_hvac_off_reason.call_count == 0
if nb_call == 1:
if new_state == STATE_OFF:
assert fake_vtherm.restore_target_temp.call_count == 1
assert fake_vtherm.save_target_temp.call_count == 0
assert fake_vtherm.change_target_temperature.call_count == 0
assert fake_vtherm.find_preset_temp.call_count == 0
else:
assert fake_vtherm.restore_target_temp.call_count == 0
assert fake_vtherm.save_target_temp.call_count == 1
assert fake_vtherm.change_target_temperature.call_count == 1
fake_vtherm.change_target_temperature.assert_has_calls(
[
call.change_target_temperature(17),
]
)
assert fake_vtherm.find_preset_temp.call_count == 1
else:
assert fake_vtherm.restore_hvac_mode.call_count == 0
assert fake_vtherm.save_target_temp.call_count == 0
assert fake_vtherm.change_target_temperature.call_count == 0
assert fake_vtherm.find_preset_temp.call_count == 0
fake_vtherm.reset_mock()
# 5. Check custom_attributes
custom_attributes = {}
window_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["window_sensor_entity_id"] == "sensor.the_window_sensor"
assert custom_attributes["window_state"] == new_state
assert custom_attributes["window_auto_state"] == STATE_UNAVAILABLE
assert custom_attributes["is_window_bypass"] is False
assert custom_attributes["is_window_configured"] is True
assert custom_attributes["is_window_auto_configured"] is False
assert custom_attributes["is_window_bypass"] is False
assert custom_attributes["window_delay_sec"] is 10
assert custom_attributes["window_auto_open_threshold"] is None
assert (
custom_attributes["window_auto_close_threshold"] is None
)
assert custom_attributes["window_auto_max_duration"] is None
window_manager.stop_listening()
await hass.async_block_till_done()
@pytest.mark.parametrize(
"current_state, long_enough, new_state, nb_call, window_state, is_window_detected",
[
(STATE_OFF, True, STATE_ON, 1, STATE_ON, True),
(STATE_OFF, True, STATE_OFF, 0, STATE_OFF, False),
(STATE_ON, True, STATE_OFF, 1, STATE_OFF, False),
(STATE_ON, True, STATE_ON, 0, STATE_ON, True),
(STATE_OFF, False, STATE_ON, 0, STATE_OFF, False),
(STATE_ON, False, STATE_OFF, 0, STATE_ON, True),
],
)
async def test_window_feature_manager_sensor_event_action_turn_off(
hass: HomeAssistant,
current_state,
long_enough,
new_state, # new state of motion event
nb_call,
window_state,
is_window_detected,
):
"""Test the FeatureMotionManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
type(fake_vtherm).preset_mode = PropertyMock(return_value=PRESET_COMFORT)
# 1. creation
window_manager = FeatureWindowManager(fake_vtherm, hass)
# 2. post_init
window_manager.post_init(
{
CONF_WINDOW_SENSOR: "sensor.the_window_sensor",
CONF_USE_WINDOW_FEATURE: True,
CONF_WINDOW_DELAY: 10,
CONF_WINDOW_ACTION: CONF_WINDOW_TURN_OFF,
}
)
# 3. start listening
window_manager.start_listening()
assert len(window_manager._active_listener) == 1
# 4. test refresh with the parametrized
# fmt:off
with patch("homeassistant.helpers.condition.state", return_value=long_enough):
# fmt:on
# Configurer les méthodes mockées
fake_vtherm.async_set_hvac_mode = AsyncMock()
fake_vtherm.set_hvac_off_reason = MagicMock()
fake_vtherm.restore_hvac_mode = AsyncMock()
# force old state for the test
window_manager._window_state = current_state
if current_state == STATE_ON:
type(fake_vtherm).hvac_off_reason = PropertyMock(return_value=HVAC_OFF_REASON_WINDOW_DETECTION)
else:
type(fake_vtherm).hvac_off_reason = PropertyMock(return_value=None)
try_window_condition = await window_manager._window_sensor_changed(
event=Event(
event_type=EVENT_STATE_CHANGED,
data={
"entity_id": "sensor.the_window_sensor",
"new_state": State("sensor.the_window_sensor", new_state),
"old_state": State("sensor.the_window_sensor", current_state),
}))
assert try_window_condition is not None
await try_window_condition(None)
# There is change only if long enough
if long_enough:
assert window_manager.window_state == new_state
else:
assert window_manager.window_state == current_state
assert fake_vtherm.set_hvac_off_reason.call_count == nb_call
if nb_call == 1:
if new_state == STATE_OFF:
assert fake_vtherm.restore_hvac_mode.call_count == 1
assert fake_vtherm.async_set_hvac_mode.call_count == 0
else:
assert fake_vtherm.async_set_hvac_mode.call_count == 1
fake_vtherm.async_set_hvac_mode.assert_has_calls(
[
call.async_set_hvac_mode(HVACMode.OFF),
]
)
assert fake_vtherm.restore_hvac_mode.call_count == 0
reason = None if current_state == STATE_ON and new_state == STATE_OFF else HVAC_OFF_REASON_WINDOW_DETECTION
fake_vtherm.set_hvac_off_reason.assert_has_calls(
[
call.set_hvac_off_reason(reason),
]
)
else:
assert fake_vtherm.restore_hvac_mode.call_count == 0
assert fake_vtherm.async_set_hvac_mode.call_count == 0
fake_vtherm.reset_mock()
# 5. Check custom_attributes
custom_attributes = {}
window_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["window_sensor_entity_id"] == "sensor.the_window_sensor"
assert custom_attributes["window_state"] == new_state if long_enough else current_state
assert custom_attributes["window_auto_state"] == STATE_UNAVAILABLE
assert custom_attributes["is_window_bypass"] is False
assert custom_attributes["is_window_configured"] is True
assert custom_attributes["is_window_auto_configured"] is False
assert custom_attributes["is_window_bypass"] is False
assert custom_attributes["window_delay_sec"] is 10
assert custom_attributes["window_auto_open_threshold"] is None
assert (
custom_attributes["window_auto_close_threshold"] is None
)
assert custom_attributes["window_auto_max_duration"] is None
window_manager.stop_listening()
await hass.async_block_till_done()
@pytest.mark.parametrize(
"current_state, long_enough, new_state, nb_call, window_state, is_window_detected",
[
(STATE_OFF, True, STATE_ON, 1, STATE_ON, True),
(STATE_OFF, True, STATE_OFF, 0, STATE_OFF, False),
(STATE_ON, True, STATE_OFF, 1, STATE_OFF, False),
(STATE_ON, True, STATE_ON, 0, STATE_ON, True),
(STATE_OFF, False, STATE_ON, 0, STATE_OFF, False),
(STATE_ON, False, STATE_OFF, 0, STATE_ON, True),
],
)
async def test_window_feature_manager_event_sensor_action_frost_only(
hass: HomeAssistant,
current_state,
long_enough,
new_state, # new state of motion event
nb_call,
window_state,
is_window_detected,
):
"""Test the FeatureMotionManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
type(fake_vtherm).preset_mode = PropertyMock(return_value=PRESET_COMFORT)
type(fake_vtherm).last_central_mode = PropertyMock(return_value=None)
# 1. creation
window_manager = FeatureWindowManager(fake_vtherm, hass)
# 2. post_init
window_manager.post_init(
{
CONF_WINDOW_SENSOR: "sensor.the_window_sensor",
CONF_USE_WINDOW_FEATURE: True,
CONF_WINDOW_DELAY: 10,
CONF_WINDOW_ACTION: CONF_WINDOW_FROST_TEMP,
}
)
# 3. start listening
window_manager.start_listening()
# 4. test refresh with the parametrized
# fmt:off
with patch("homeassistant.helpers.condition.state", return_value=long_enough):
# fmt:on
# Configurer les méthodes mockées
fake_vtherm.save_target_temp = AsyncMock()
fake_vtherm.set_hvac_off_reason = MagicMock()
fake_vtherm.restore_target_temp = AsyncMock()
fake_vtherm.change_target_temperature = AsyncMock()
fake_vtherm.find_preset_temp = MagicMock()
fake_vtherm.find_preset_temp.return_value = 17
# force old state for the test
window_manager._window_state = current_state
if current_state == STATE_ON:
type(fake_vtherm).hvac_off_reason = PropertyMock(return_value=HVAC_OFF_REASON_WINDOW_DETECTION)
else:
type(fake_vtherm).hvac_off_reason = PropertyMock(return_value=None)
try_window_condition = await window_manager._window_sensor_changed(
event=Event(
event_type=EVENT_STATE_CHANGED,
data={
"entity_id": "sensor.the_window_sensor",
"new_state": State("sensor.the_window_sensor", new_state),
"old_state": State("sensor.the_window_sensor", current_state),
}))
assert try_window_condition is not None
await try_window_condition(None)
if long_enough:
assert window_manager.window_state == new_state
else:
assert window_manager.window_state == current_state
assert fake_vtherm.set_hvac_off_reason.call_count == 0
if nb_call == 1:
if new_state == STATE_OFF:
assert fake_vtherm.restore_target_temp.call_count == 1
assert fake_vtherm.save_target_temp.call_count == 0
assert fake_vtherm.change_target_temperature.call_count == 0
assert fake_vtherm.find_preset_temp.call_count == 0
else:
assert fake_vtherm.restore_target_temp.call_count == 0
assert fake_vtherm.save_target_temp.call_count == 1
assert fake_vtherm.change_target_temperature.call_count == 1
fake_vtherm.change_target_temperature.assert_has_calls(
[
call.change_target_temperature(17),
]
)
assert fake_vtherm.find_preset_temp.call_count == 1
else:
assert fake_vtherm.restore_hvac_mode.call_count == 0
assert fake_vtherm.save_target_temp.call_count == 0
assert fake_vtherm.change_target_temperature.call_count == 0
assert fake_vtherm.find_preset_temp.call_count == 0
fake_vtherm.reset_mock()
# 5. Check custom_attributes
custom_attributes = {}
window_manager.add_custom_attributes(custom_attributes)
assert custom_attributes["window_sensor_entity_id"] == "sensor.the_window_sensor"
assert custom_attributes["window_state"] == new_state if long_enough else current_state
assert custom_attributes["window_auto_state"] == STATE_UNAVAILABLE
assert custom_attributes["is_window_bypass"] is False
assert custom_attributes["is_window_configured"] is True
assert custom_attributes["is_window_auto_configured"] is False
assert custom_attributes["is_window_bypass"] is False
assert custom_attributes["window_delay_sec"] is 10
assert custom_attributes["window_auto_open_threshold"] is None
assert (
custom_attributes["window_auto_close_threshold"] is None
)
assert custom_attributes["window_auto_max_duration"] is None
window_manager.stop_listening()
await hass.async_block_till_done()
@pytest.mark.parametrize(
"current_state, in_cycle, new_temp, new_state, nb_call, window_state, is_window_detected",
[
(STATE_OFF, True, 10, STATE_ON, 1, STATE_ON, True),
(STATE_ON, True, 10, STATE_ON, 0, STATE_ON, True),
(STATE_ON, True, 20, STATE_OFF, 1, STATE_OFF, False),
(STATE_OFF, True, 20, STATE_OFF, 0, STATE_OFF, False),
],
)
async def test_window_feature_manager_window_auto(
hass: HomeAssistant,
current_state,
in_cycle,
new_temp,
new_state, # new state of motion event
nb_call,
window_state,
is_window_detected,
):
"""Test the FeatureMotionManager class direclty"""
fake_vtherm = MagicMock(spec=BaseThermostat)
type(fake_vtherm).name = PropertyMock(return_value="the name")
type(fake_vtherm).preset_mode = PropertyMock(return_value=PRESET_COMFORT)
type(fake_vtherm).hvac_mode = PropertyMock(return_value=HVACMode.HEAT)
type(fake_vtherm).last_central_mode = PropertyMock(return_value=None)
type(fake_vtherm).proportional_algorithm = PropertyMock(return_value=None)
# 1. creation / post_init / start listening
window_manager = FeatureWindowManager(fake_vtherm, hass)
window_manager.post_init(
{
CONF_USE_WINDOW_FEATURE: True,
CONF_WINDOW_AUTO_OPEN_THRESHOLD: 3,
CONF_WINDOW_AUTO_CLOSE_THRESHOLD: 1,
CONF_WINDOW_AUTO_MAX_DURATION: 10,
CONF_WINDOW_ACTION: CONF_WINDOW_TURN_OFF,
}
)
assert window_manager.is_window_auto_configured is True
window_manager.start_listening()
# 2. Call manage window auto
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
# Add a fake temp point for the window_auto_algo. We need at least 4 points
for i in range(0, 4):
window_manager._window_auto_algo.add_temp_measurement(
17 + (i * (new_temp - 17) / 4), now, True
)
now = now + timedelta(minutes=5)
# fmt:off
with patch("custom_components.versatile_thermostat.feature_window_manager.FeatureWindowManager.update_window_state") as mock_update_window_state:
#fmt: on
now = now + timedelta(minutes=10)
# From 17 to new_temp in 10 minutes
type(fake_vtherm).ema_temperature = PropertyMock(return_value=new_temp)
type(fake_vtherm).last_temperature_measure = PropertyMock(return_value=now)
type(fake_vtherm).now = PropertyMock(return_value=now)
fake_vtherm.send_event = MagicMock()
window_manager._window_auto_state = current_state
dearm_window_auto = await window_manager.manage_window_auto(in_cycle=in_cycle)
assert dearm_window_auto is not None
assert mock_update_window_state.call_count == nb_call
if nb_call > 0:
mock_update_window_state.assert_has_calls(
[
call.update_window_state(new_state),
]
)
if new_state == STATE_ON:
assert window_manager._window_call_cancel is not None
assert window_manager.window_auto_state == new_state
# update_window_state is mocked
# assert window_manager.window_state == new_state
window_manager.stop_listening()
await hass.async_block_till_done()