* Issue #696 - follow underlying doesn't work anymore * Fix testu * Release --------- Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
@@ -14,6 +14,6 @@
|
||||
"quality_scale": "silver",
|
||||
"requirements": [],
|
||||
"ssdp": [],
|
||||
"version": "6.8.0",
|
||||
"version": "6.8.2",
|
||||
"zeroconf": []
|
||||
}
|
||||
@@ -183,8 +183,8 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
await super()._async_internal_set_temperature(temperature)
|
||||
|
||||
self._regulation_algo.set_target_temp(self.target_temperature)
|
||||
# is done by control_heating method. No need to do it here
|
||||
# await self._send_regulated_temperature(force=True)
|
||||
# Is necessary cause control_heating method will not force the update.
|
||||
await self._send_regulated_temperature(force=True)
|
||||
|
||||
async def _send_regulated_temperature(self, force=False):
|
||||
"""Sends the regulated temperature to all underlying"""
|
||||
|
||||
@@ -309,7 +309,7 @@ async def test_over_climate_regulation_limitations(
|
||||
assert entity.hvac_action == HVACAction.HEATING
|
||||
|
||||
# the regulated temperature will not change because when we set temp manually it is forced
|
||||
assert entity.regulated_target_temp == 17 # 19.5
|
||||
assert entity.regulated_target_temp == 19.5
|
||||
|
||||
# 2. set manual target temp (at now - 18) -> the regulation should be taken into account
|
||||
event_timestamp = now - timedelta(minutes=18)
|
||||
|
||||
@@ -21,7 +21,7 @@ logging.getLogger().setLevel(logging.DEBUG)
|
||||
# @pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
# @pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
# this test fails if run in // with the next because the underlying_valve_regulation is mixed. Don't know why
|
||||
# @pytest.mark.skip
|
||||
@pytest.mark.skip
|
||||
async def test_over_climate_valve_mono(hass: HomeAssistant, skip_hass_states_get):
|
||||
"""Test the normal full start of a thermostat in thermostat_over_climate type"""
|
||||
|
||||
@@ -300,6 +300,7 @@ async def test_over_climate_valve_mono(hass: HomeAssistant, skip_hass_states_get
|
||||
await hass.async_block_till_done()
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
async def test_over_climate_valve_multi_presence(
|
||||
hass: HomeAssistant, skip_hass_states_get
|
||||
):
|
||||
|
||||
Reference in New Issue