@@ -231,16 +231,8 @@ STEP_TPI_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
|
||||
STEP_CENTRAL_TPI_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
{
|
||||
vol.Required(CONF_TPI_COEF_INT, default=0.6): selector.NumberSelector(
|
||||
selector.NumberSelectorConfig(
|
||||
min=0.0, max=1.0, step=0.01, mode=selector.NumberSelectorMode.BOX
|
||||
)
|
||||
),
|
||||
vol.Required(CONF_TPI_COEF_EXT, default=0.01): selector.NumberSelector(
|
||||
selector.NumberSelectorConfig(
|
||||
min=0.0, max=1.0, step=0.01, mode=selector.NumberSelectorMode.BOX
|
||||
)
|
||||
),
|
||||
vol.Required(CONF_TPI_COEF_INT, default=0.6): selector.NumberSelector(selector.NumberSelectorConfig(min=0.0, max=1.0, step=0.01, mode=selector.NumberSelectorMode.BOX)),
|
||||
vol.Required(CONF_TPI_COEF_EXT, default=0.01): selector.NumberSelector(selector.NumberSelectorConfig(min=0.0, max=1.0, mode=selector.NumberSelectorMode.BOX)),
|
||||
}
|
||||
)
|
||||
|
||||
@@ -265,12 +257,11 @@ STEP_WINDOW_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
STEP_CENTRAL_WINDOW_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
{
|
||||
vol.Optional(CONF_WINDOW_DELAY, default=30): cv.positive_int,
|
||||
vol.Optional(CONF_WINDOW_OFF_DELAY, default=30): cv.positive_int,
|
||||
vol.Optional(CONF_WINDOW_AUTO_OPEN_THRESHOLD, default=3): vol.Coerce(float),
|
||||
vol.Optional(CONF_WINDOW_AUTO_CLOSE_THRESHOLD, default=0): vol.Coerce(float),
|
||||
vol.Optional(CONF_WINDOW_AUTO_MAX_DURATION, default=30): cv.positive_int,
|
||||
vol.Optional(
|
||||
CONF_WINDOW_ACTION, default=CONF_WINDOW_TURN_OFF
|
||||
): selector.SelectSelector(
|
||||
vol.Optional(CONF_WINDOW_ACTION, default=CONF_WINDOW_TURN_OFF): selector.SelectSelector(
|
||||
selector.SelectSelectorConfig(
|
||||
options=CONF_WINDOW_ACTIONS,
|
||||
translation_key="window_action",
|
||||
@@ -283,9 +274,8 @@ STEP_CENTRAL_WINDOW_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
STEP_CENTRAL_WINDOW_WO_AUTO_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
{
|
||||
vol.Optional(CONF_WINDOW_DELAY, default=30): cv.positive_int,
|
||||
vol.Optional(
|
||||
CONF_WINDOW_ACTION, default=CONF_WINDOW_TURN_OFF
|
||||
): selector.SelectSelector(
|
||||
vol.Optional(CONF_WINDOW_OFF_DELAY, default=30): cv.positive_int,
|
||||
vol.Optional(CONF_WINDOW_ACTION, default=CONF_WINDOW_TURN_OFF): selector.SelectSelector(
|
||||
selector.SelectSelectorConfig(
|
||||
options=CONF_WINDOW_ACTIONS,
|
||||
translation_key="window_action",
|
||||
|
||||
@@ -73,6 +73,7 @@ CONF_DEVICE_POWER = "device_power"
|
||||
CONF_CYCLE_MIN = "cycle_min"
|
||||
CONF_PROP_FUNCTION = "proportional_function"
|
||||
CONF_WINDOW_DELAY = "window_delay"
|
||||
CONF_WINDOW_OFF_DELAY = "window_off_delay"
|
||||
CONF_MOTION_DELAY = "motion_delay"
|
||||
CONF_MOTION_OFF_DELAY = "motion_off_delay"
|
||||
CONF_MOTION_PRESET = "motion_preset"
|
||||
@@ -270,6 +271,7 @@ ALL_CONF = (
|
||||
CONF_MAX_POWER_SENSOR,
|
||||
CONF_WINDOW_SENSOR,
|
||||
CONF_WINDOW_DELAY,
|
||||
CONF_WINDOW_OFF_DELAY,
|
||||
CONF_WINDOW_AUTO_OPEN_THRESHOLD,
|
||||
CONF_WINDOW_AUTO_CLOSE_THRESHOLD,
|
||||
CONF_WINDOW_AUTO_MAX_DURATION,
|
||||
|
||||
@@ -23,12 +23,7 @@ from homeassistant.helpers.event import (
|
||||
EventStateChangedData,
|
||||
)
|
||||
|
||||
from homeassistant.components.climate import (
|
||||
PRESET_ACTIVITY,
|
||||
PRESET_BOOST,
|
||||
PRESET_COMFORT,
|
||||
PRESET_ECO,
|
||||
)
|
||||
from homeassistant.components.climate import PRESET_ACTIVITY, PRESET_BOOST, PRESET_COMFORT, PRESET_ECO
|
||||
|
||||
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
|
||||
from .commons import ConfigData
|
||||
@@ -146,6 +141,7 @@ class FeaturePresenceManager(BaseFeatureManager):
|
||||
PRESET_COMFORT,
|
||||
PRESET_ECO,
|
||||
PRESET_ACTIVITY,
|
||||
PRESET_FROST_PROTECTION,
|
||||
]:
|
||||
return old_presence_state != self._presence_state
|
||||
|
||||
|
||||
@@ -46,6 +46,7 @@ class FeatureWindowManager(BaseFeatureManager):
|
||||
"is_window_configured",
|
||||
"is_window_bypass",
|
||||
"window_delay_sec",
|
||||
"window_off_delay_sec",
|
||||
"window_auto_configured",
|
||||
"window_auto_open_threshold",
|
||||
"window_auto_close_threshold",
|
||||
@@ -67,6 +68,7 @@ class FeatureWindowManager(BaseFeatureManager):
|
||||
self._is_window_bypass: bool = False
|
||||
self._window_action: str = None
|
||||
self._window_delay_sec: int | None = 0
|
||||
self._window_off_delay_sec: int | None = 0
|
||||
self._is_configured: bool = False
|
||||
self._is_window_auto_configured: bool = False
|
||||
self._window_call_cancel: callable = None
|
||||
@@ -81,6 +83,8 @@ class FeatureWindowManager(BaseFeatureManager):
|
||||
|
||||
self._window_sensor_entity_id = entry_infos.get(CONF_WINDOW_SENSOR)
|
||||
self._window_delay_sec = entry_infos.get(CONF_WINDOW_DELAY)
|
||||
# default is the WINDOW_ON delay if not configured
|
||||
self._window_off_delay_sec = entry_infos.get(CONF_WINDOW_OFF_DELAY, self._window_delay_sec)
|
||||
|
||||
self._window_action = (
|
||||
entry_infos.get(CONF_WINDOW_ACTION) or CONF_WINDOW_TURN_OFF
|
||||
@@ -191,7 +195,7 @@ class FeatureWindowManager(BaseFeatureManager):
|
||||
self._hass,
|
||||
self._window_sensor_entity_id,
|
||||
new_state.state,
|
||||
timedelta(seconds=self._window_delay_sec),
|
||||
timedelta(seconds=delay),
|
||||
)
|
||||
except ConditionError:
|
||||
long_enough = False
|
||||
@@ -221,13 +225,12 @@ class FeatureWindowManager(BaseFeatureManager):
|
||||
|
||||
self._vtherm.update_custom_attributes()
|
||||
|
||||
delay = self._window_delay_sec if new_state.state == STATE_ON else self._window_off_delay_sec
|
||||
if new_state is None or old_state is None or new_state.state == old_state.state:
|
||||
return try_window_condition
|
||||
|
||||
self.dearm_window_timer()
|
||||
self._window_call_cancel = async_call_later(
|
||||
self.hass, timedelta(seconds=self._window_delay_sec), try_window_condition
|
||||
)
|
||||
self._window_call_cancel = async_call_later(self.hass, timedelta(seconds=delay), try_window_condition)
|
||||
# For testing purpose we need to access the inner function
|
||||
return try_window_condition
|
||||
|
||||
@@ -433,6 +436,7 @@ class FeatureWindowManager(BaseFeatureManager):
|
||||
"is_window_bypass": self._is_window_bypass,
|
||||
"window_sensor_entity_id": self._window_sensor_entity_id,
|
||||
"window_delay_sec": self._window_delay_sec,
|
||||
"window_off_delay_sec": self._window_off_delay_sec,
|
||||
"is_window_configured": self._is_configured,
|
||||
"is_window_auto_configured": self._is_window_auto_configured,
|
||||
"window_auto_open_threshold": self._window_auto_open_threshold,
|
||||
@@ -512,9 +516,14 @@ class FeatureWindowManager(BaseFeatureManager):
|
||||
|
||||
@property
|
||||
def window_delay_sec(self) -> bool:
|
||||
"""Return the motion delay"""
|
||||
"""Return the window on delay"""
|
||||
return self._window_delay_sec
|
||||
|
||||
@property
|
||||
def window_off_delay_sec(self) -> bool:
|
||||
"""Return the window off delay"""
|
||||
return self._window_off_delay_sec
|
||||
|
||||
@property
|
||||
def window_action(self) -> bool:
|
||||
"""Return the window action"""
|
||||
|
||||
@@ -14,6 +14,6 @@
|
||||
"quality_scale": "silver",
|
||||
"requirements": [],
|
||||
"ssdp": [],
|
||||
"version": "7.1.1",
|
||||
"version": "7.1.3",
|
||||
"zeroconf": []
|
||||
}
|
||||
@@ -123,7 +123,8 @@
|
||||
"description": "Open window management.\nYou can also configure automatic window open detection based on temperature decrease",
|
||||
"data": {
|
||||
"window_sensor_entity_id": "Window sensor entity id",
|
||||
"window_delay": "Window sensor delay (seconds)",
|
||||
"window_delay": "Window sensor 'on' delay (seconds)",
|
||||
"window_off_delay": "Window sensor 'off' delay (seconds)",
|
||||
"window_auto_open_threshold": "Temperature decrease threshold for automatic window open detection (in °/hours)",
|
||||
"window_auto_close_threshold": "Temperature increase threshold for end of automatic detection (in °/hours)",
|
||||
"window_auto_max_duration": "Maximum duration of automatic window open detection (in min)",
|
||||
@@ -132,7 +133,8 @@
|
||||
},
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "Leave empty if no window sensor should be used and to use the automatic detection",
|
||||
"window_delay": "The delay in seconds before sensor detection is taken into account",
|
||||
"window_delay": "The delay in seconds before sensor 'on' detection is taken into account",
|
||||
"window_off_delay": "The delay in seconds before sensor 'off' detection is taken into account. Leave it empty to use the same value as window on delay",
|
||||
"window_auto_open_threshold": "Recommended value: between 3 and 10. Leave empty if automatic window open detection is not used",
|
||||
"window_auto_close_threshold": "Recommended value: 0. Leave empty if automatic window open detection is not used",
|
||||
"window_auto_max_duration": "Recommended value: 60 (one hour). Leave empty if automatic window open detection is not used",
|
||||
@@ -228,11 +230,11 @@
|
||||
"min_opening_degrees": "Min opening degrees"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV has the entity for better regulation. There should be one per underlying climate entities",
|
||||
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV has the entity for better regulation. There should be one per underlying climate entities",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"min_opening_degrees": "A comma seperated list of minimal opening degrees. Default to 0. Example: 20, 25, 30"
|
||||
"min_opening_degrees": "Opening degree minimum value for each underlying device, comma separated. Default to 0. Example: 20, 25, 30"
|
||||
}
|
||||
}
|
||||
},
|
||||
@@ -369,7 +371,8 @@
|
||||
"description": "Open window management.\nYou can also configure automatic window open detection based on temperature decrease",
|
||||
"data": {
|
||||
"window_sensor_entity_id": "Window sensor entity id",
|
||||
"window_delay": "Window sensor delay (seconds)",
|
||||
"window_delay": "Window sensor 'on' delay (seconds)",
|
||||
"window_off_delay": "Window sensor 'off' delay (seconds)",
|
||||
"window_auto_open_threshold": "Temperature decrease threshold for automatic window open detection (in °/hours)",
|
||||
"window_auto_close_threshold": "Temperature increase threshold for end of automatic detection (in °/hours)",
|
||||
"window_auto_max_duration": "Maximum duration of automatic window open detection (in min)",
|
||||
@@ -378,8 +381,8 @@
|
||||
},
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "Leave empty if no window sensor should be used and to use the automatic detection",
|
||||
"window_delay": "The delay in seconds before sensor detection is taken into account",
|
||||
"window_auto_open_threshold": "Recommended value: between 3 and 10. Leave empty if automatic window open detection is not used",
|
||||
"window_delay": "The delay in seconds before sensor 'on' detection is taken into account",
|
||||
"window_off_delay": "The delay in seconds before sensor 'off' detection is taken into account. Leave it empty to use the same value as window on delay",
|
||||
"window_auto_close_threshold": "Recommended value: 0. Leave empty if automatic window open detection is not used",
|
||||
"window_auto_max_duration": "Recommended value: 60 (one hour). Leave empty if automatic window open detection is not used",
|
||||
"use_window_central_config": "Check to use the central window configuration. Uncheck to use a specific window configuration for this VTherm",
|
||||
@@ -474,11 +477,11 @@
|
||||
"min_opening_degrees": "Min opening degrees"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV has the entity for better regulation. There should be one per underlying climate entities",
|
||||
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV has the entity for better regulation. There should be one per underlying climate entities",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"min_opening_degrees": "A comma seperated list of minimal opening degrees. Default to 0. Example: 20, 25, 30"
|
||||
"min_opening_degrees": "Opening degree minimum value for each underlying device, comma separated. Default to 0. Example: 20, 25, 30"
|
||||
}
|
||||
}
|
||||
},
|
||||
|
||||
@@ -255,6 +255,10 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
|
||||
self._attr_min_temp,
|
||||
)
|
||||
|
||||
self._last_regulation_change = self.now
|
||||
|
||||
_LOGGER.debug("%s - last_regulation_change is now: %s", self, self._last_regulation_change)
|
||||
|
||||
for under in self._underlyings_valve_regulation:
|
||||
await under.set_valve_open_percent()
|
||||
|
||||
@@ -263,11 +267,6 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
|
||||
"""True if the Thermostat is regulated by valve"""
|
||||
return True
|
||||
|
||||
# @property
|
||||
# def hvac_modes(self) -> list[HVACMode]:
|
||||
# """Get the hvac_modes"""
|
||||
# return self._hvac_list
|
||||
|
||||
@property
|
||||
def valve_open_percent(self) -> int:
|
||||
"""Gives the percentage of valve needed"""
|
||||
|
||||
@@ -123,7 +123,8 @@
|
||||
"description": "Open window management.\nYou can also configure automatic window open detection based on temperature decrease",
|
||||
"data": {
|
||||
"window_sensor_entity_id": "Window sensor entity id",
|
||||
"window_delay": "Window sensor delay (seconds)",
|
||||
"window_delay": "Window sensor 'on' delay (seconds)",
|
||||
"window_off_delay": "Window sensor 'off' delay (seconds)",
|
||||
"window_auto_open_threshold": "Temperature decrease threshold for automatic window open detection (in °/hours)",
|
||||
"window_auto_close_threshold": "Temperature increase threshold for end of automatic detection (in °/hours)",
|
||||
"window_auto_max_duration": "Maximum duration of automatic window open detection (in min)",
|
||||
@@ -132,7 +133,8 @@
|
||||
},
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "Leave empty if no window sensor should be used and to use the automatic detection",
|
||||
"window_delay": "The delay in seconds before sensor detection is taken into account",
|
||||
"window_delay": "The delay in seconds before sensor 'on' detection is taken into account",
|
||||
"window_off_delay": "The delay in seconds before sensor 'off' detection is taken into account. Leave it empty to use the same value as window on delay",
|
||||
"window_auto_open_threshold": "Recommended value: between 3 and 10. Leave empty if automatic window open detection is not used",
|
||||
"window_auto_close_threshold": "Recommended value: 0. Leave empty if automatic window open detection is not used",
|
||||
"window_auto_max_duration": "Recommended value: 60 (one hour). Leave empty if automatic window open detection is not used",
|
||||
@@ -228,9 +230,9 @@
|
||||
"min_opening_degrees": "Min opening degrees"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV has the entity for better regulation. There should be one per underlying climate entities",
|
||||
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV has the entity for better regulation. There should be one per underlying climate entities",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"min_opening_degrees": "A comma seperated list of minimal opening degrees. Default to 0. Example: 20, 25, 30"
|
||||
}
|
||||
@@ -369,7 +371,8 @@
|
||||
"description": "Open window management.\nYou can also configure automatic window open detection based on temperature decrease",
|
||||
"data": {
|
||||
"window_sensor_entity_id": "Window sensor entity id",
|
||||
"window_delay": "Window sensor delay (seconds)",
|
||||
"window_delay": "Window sensor 'on' delay (seconds)",
|
||||
"window_off_delay": "Window sensor 'off' delay (seconds)",
|
||||
"window_auto_open_threshold": "Temperature decrease threshold for automatic window open detection (in °/hours)",
|
||||
"window_auto_close_threshold": "Temperature increase threshold for end of automatic detection (in °/hours)",
|
||||
"window_auto_max_duration": "Maximum duration of automatic window open detection (in min)",
|
||||
@@ -378,8 +381,8 @@
|
||||
},
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "Leave empty if no window sensor should be used and to use the automatic detection",
|
||||
"window_delay": "The delay in seconds before sensor detection is taken into account",
|
||||
"window_auto_open_threshold": "Recommended value: between 3 and 10. Leave empty if automatic window open detection is not used",
|
||||
"window_delay": "The delay in seconds before sensor 'on' detection is taken into account",
|
||||
"window_off_delay": "The delay in seconds before sensor 'off' detection is taken into account. Leave it empty to use the same value as window on delay",
|
||||
"window_auto_close_threshold": "Recommended value: 0. Leave empty if automatic window open detection is not used",
|
||||
"window_auto_max_duration": "Recommended value: 60 (one hour). Leave empty if automatic window open detection is not used",
|
||||
"use_window_central_config": "Check to use the central window configuration. Uncheck to use a specific window configuration for this VTherm",
|
||||
@@ -474,9 +477,9 @@
|
||||
"min_opening_degrees": "Min opening degrees"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV has the entity for better regulation. There should be one per underlying climate entities",
|
||||
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV has the entity for better regulation. There should be one per underlying climate entities",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"min_opening_degrees": "A comma seperated list of minimal opening degrees. Default to 0. Example: 20, 25, 30"
|
||||
}
|
||||
@@ -488,7 +491,8 @@
|
||||
"window_open_detection_method": "Only one window open detection method should be used. Use either window sensor or automatic detection through temperature threshold but not both",
|
||||
"no_central_config": "You cannot check 'use central configuration' because no central configuration was found. You need to create a Versatile Thermostat of type 'Central Configuration' to use it.",
|
||||
"service_configuration_format": "The format of the service configuration is wrong",
|
||||
"valve_regulation_nb_entities_incorrect": "The number of valve entities for valve regulation should be equal to the number of underlyings"
|
||||
"valve_regulation_nb_entities_incorrect": "The number of valve entities for valve regulation should be equal to the number of underlyings",
|
||||
"min_opening_degrees_format": "A comma separated list of positive integer is expected. Example: 20, 25, 30"
|
||||
},
|
||||
"abort": {
|
||||
"already_configured": "Device is already configured"
|
||||
|
||||
@@ -123,7 +123,8 @@
|
||||
"description": "Coupe le radiateur si l'ouverture est ouverte.\nLaissez l'id d'entité vide pour utiliser la détection automatique.",
|
||||
"data": {
|
||||
"window_sensor_entity_id": "Détecteur d'ouverture (entity id)",
|
||||
"window_delay": "Délai avant extinction (secondes)",
|
||||
"window_delay": "Délai de prise en compte à l'ouverture (secondes)",
|
||||
"window_off_delay": "Délai de prise compte à la fermeture (secondes)",
|
||||
"window_auto_open_threshold": "Seuil haut de chute de température pour la détection automatique (en °/heure)",
|
||||
"window_auto_close_threshold": "Seuil bas de chute de température pour la fin de détection automatique (en °/heure)",
|
||||
"window_auto_max_duration": "Durée maximum d'une extinction automatique (en min)",
|
||||
@@ -132,7 +133,8 @@
|
||||
},
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "Laissez vide si vous n'avez de détecteur et pour utiliser la détection automatique",
|
||||
"window_delay": "Le délai (en secondes) avant que le changement du détecteur soit pris en compte",
|
||||
"window_delay": "Le délai (en secondes) avant que le changement du détecteur soit pris en compte lors de la détection d'une ouverture",
|
||||
"window_off_delay": "Le délai (en secondes) avant que le changement du détecteur soit pris en compte lors de la détection d'une fermeture. Laissez vide pour utiliser le même délai à l'ouveture et à la fermeture",
|
||||
"window_auto_open_threshold": "Valeur recommandée: entre 3 et 10. Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"window_auto_close_threshold": "Valeur recommandée: 0. Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"window_auto_max_duration": "Valeur recommandée: 60 (1 heure). Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
@@ -364,6 +366,7 @@
|
||||
"data": {
|
||||
"window_sensor_entity_id": "Détecteur d'ouverture (entity id)",
|
||||
"window_delay": "Délai avant extinction (secondes)",
|
||||
"window_off_delay": "Délai de prise compte à la fermeture (secondes)",
|
||||
"window_auto_open_threshold": "Seuil haut de chute de température pour la détection automatique (en °/heure)",
|
||||
"window_auto_close_threshold": "Seuil bas de chute de température pour la fin de détection automatique (en °/heure)",
|
||||
"window_auto_max_duration": "Durée maximum d'une extinction automatique (en min)",
|
||||
@@ -373,6 +376,7 @@
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "Laissez vide si vous n'avez de détecteur et pour utiliser la détection automatique",
|
||||
"window_delay": "Le délai (en secondes) avant que le changement du détecteur soit pris en compte",
|
||||
"window_off_delay": "Le délai (en secondes) avant que le changement du détecteur soit pris en compte lors de la détection d'une fermeture. Laissez vide pour utiliser le même délai à l'ouveture et à la fermeture",
|
||||
"window_auto_open_threshold": "Valeur recommandée: entre 3 et 10. Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"window_auto_close_threshold": "Valeur recommandée: 0. Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"window_auto_max_duration": "Valeur recommandée: 60 (1 heure). Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
|
||||
@@ -632,22 +632,23 @@ class UnderlyingClimate(UnderlyingEntity):
|
||||
|
||||
# Issue 508 we have to take care of service set_temperature or set_range
|
||||
target_temp = self.cap_sent_value(temperature)
|
||||
if (
|
||||
ClimateEntityFeature.TARGET_TEMPERATURE_RANGE
|
||||
in self._underlying_climate.supported_features
|
||||
):
|
||||
data = {
|
||||
ATTR_ENTITY_ID: self._entity_id,
|
||||
"target_temp_high": target_temp,
|
||||
"target_temp_low": target_temp,
|
||||
# issue 518 - we should send also the target temperature, even in TARGET RANGE
|
||||
"temperature": target_temp,
|
||||
}
|
||||
else:
|
||||
data = {
|
||||
ATTR_ENTITY_ID: self._entity_id,
|
||||
"temperature": target_temp,
|
||||
}
|
||||
data = {
|
||||
ATTR_ENTITY_ID: self._entity_id,
|
||||
}
|
||||
|
||||
_LOGGER.info("%s - Set setpoint temperature to: %s", self, target_temp)
|
||||
|
||||
# Issue 807 add TARGET_TEMPERATURE only if in the features
|
||||
if ClimateEntityFeature.TARGET_TEMPERATURE_RANGE in self._underlying_climate.supported_features:
|
||||
data.update(
|
||||
{
|
||||
"target_temp_high": target_temp,
|
||||
"target_temp_low": target_temp,
|
||||
}
|
||||
)
|
||||
|
||||
if ClimateEntityFeature.TARGET_TEMPERATURE in self._underlying_climate.supported_features:
|
||||
data["temperature"] = target_temp
|
||||
|
||||
await self._hass.services.async_call(
|
||||
CLIMATE_DOMAIN,
|
||||
@@ -656,6 +657,7 @@ class UnderlyingClimate(UnderlyingEntity):
|
||||
)
|
||||
|
||||
self._last_sent_temperature = target_temp
|
||||
_LOGGER.debug("%s - Last_sent_temperature is now: %s", self, self._last_sent_temperature)
|
||||
|
||||
@property
|
||||
def last_sent_temperature(self) -> float | None:
|
||||
|
||||
@@ -15,7 +15,7 @@ Provide the mandatory main attributes. These attributes are common to all VTherm
|
||||
1. For `over_switch`: VTherm will turn the radiator on/off, modulating the proportion of time it is on,
|
||||
2. For `over_valve`: VTherm will calculate a new valve opening level and send it if it has changed,
|
||||
3. For `over_climate`: The cycle performs basic controls and recalculates the self-regulation coefficients. The cycle may result in a new setpoint sent to underlying devices or a valve opening adjustment in the case of a controllable TRV.
|
||||
5. The equipment's power, which will activate power and energy consumption sensors for the device. If multiple devices are linked to the same VTherm, specify the total maximum power of all devices here,
|
||||
5. The equipment's power, which will activate power and energy consumption sensors for the device. If multiple devices are linked to the same VTherm, specify the total maximum power of all devices here. The power unit is not important here. What is important is that all _VTherm_ and all power sensors have the same unit (see: Power shedding feature),
|
||||
6. The option to use additional parameters from centralized configuration:
|
||||
1. Outdoor temperature sensor,
|
||||
2. Minimum/maximum temperature and temperature step size,
|
||||
@@ -42,4 +42,4 @@ Choose the features you want to use for this VTherm:
|
||||
>  _*Notes*_
|
||||
> 1. The list of available functions adapts to your VTherm type.
|
||||
> 2. When you enable a function, a new menu entry is added to configure it.
|
||||
> 3. You cannot validate the creation of a VTherm if all parameters for all enabled functions have not been configured.
|
||||
> 3. You cannot validate the creation of a VTherm if all parameters for all enabled functions have not been configured.
|
||||
|
||||
@@ -15,7 +15,7 @@ Donnez les principaux attributs obligatoires. Ces attributs sont communs à tous
|
||||
1. `over_switch` : VTherm allumera/éteindra le radiateur en modulant la proportion de temps allumé,
|
||||
2. `over_valve` : VTherm calculera une nouvelle ouverture de la vanne et lui enverra si elle a changée,
|
||||
3. `over_climate` : le cycle permet d'effectuer les contrôles de base et recalcule les coefficients de l'auto-régulation. Le cycle peut déboucher sur une nouvelle consigne envoyée au sous-jacents ou sur une modification d'ouverture de la vanne dans le cas d'un _TRV_ dont la vanne est commandable.
|
||||
7. une puissance de l'équipement ce qui va activer les capteurs de puissance et énergie consommée par l'appareil. Si plusieurs équipements sont reliés au même VTherm, il faut indiquer ici le total des puissances max des équipements,
|
||||
7. une puissance de l'équipement ce qui va activer les capteurs de puissance et énergie consommée par l'appareil. Si plusieurs équipements sont reliés au même VTherm, il faut indiquer ici le total des puissances max des équipements. L'unité n'est pas importante. Ce qui est important c'est toutes les puissances de tous les _VTherms_ soient dans la même unité ainsi que les éventuels capteurs de puissance (cf. la fonction de délestage),
|
||||
8. la possibilité d'utiliser des paramètres complémentaires venant de la configuration centralisée :
|
||||
1. capteur de température extérieure,
|
||||
2. température minimale / maximale et pas de température
|
||||
|
||||
@@ -39,7 +39,7 @@ Il est possible de choisir un thermostat `over_climate` qui commande une climati
|
||||
|
||||
### L'auto-régulation
|
||||
|
||||
En mode `over_cliamte`, le device utilise son propre algorithme de régulation : il s'allume / s'éteint et se met en pause tout seul en fonction de la consigne transmise par le VTherm à travers son entité `climate`. Il utilise pour ça son thermomètre interne et la consigne reçue.
|
||||
En mode `over_climate`, le device utilise son propre algorithme de régulation : il s'allume / s'éteint et se met en pause tout seul en fonction de la consigne transmise par le VTherm à travers son entité `climate`. Il utilise pour ça son thermomètre interne et la consigne reçue.
|
||||
|
||||
Selon l'équipement cette régulation interne peut être plus ou moins bonne. Ca dépend beaucoup de la qualité de l'équipement, du fonctionnement de son thermomètre interne et de son algorithme interne. Pour améliorer les équipements qui régule mal, VTherm propose de tricher un peu sur la consigne qui lui est envoyée en augmentant ou diminuant celle-ci en fonction cette fois de la température de la pièce mesurée par VTherm et non plus de la température interne.
|
||||
|
||||
|
||||
@@ -3,5 +3,5 @@
|
||||
"content_in_root": false,
|
||||
"render_readme": true,
|
||||
"hide_default_branch": false,
|
||||
"homeassistant": "2024.12.4"
|
||||
"homeassistant": "2025.1.2"
|
||||
}
|
||||
@@ -1 +1 @@
|
||||
homeassistant==2024.12.4
|
||||
homeassistant==2025.1.2
|
||||
|
||||
@@ -182,6 +182,7 @@ FULL_CENTRAL_CONFIG = {
|
||||
"comfort_ac_away_temp": 0,
|
||||
"boost_ac_away_temp": 30.7,
|
||||
CONF_WINDOW_DELAY: 15,
|
||||
CONF_WINDOW_OFF_DELAY: 30,
|
||||
CONF_WINDOW_AUTO_OPEN_THRESHOLD: 4,
|
||||
CONF_WINDOW_AUTO_CLOSE_THRESHOLD: 1,
|
||||
CONF_WINDOW_AUTO_MAX_DURATION: 31,
|
||||
|
||||
@@ -452,7 +452,7 @@ async def test_over_switch_with_central_config_but_no_central_config(
|
||||
DOMAIN, context={"source": SOURCE_USER}
|
||||
)
|
||||
|
||||
assert result["type"] == data_entry_flow.RESULT_TYPE_FORM
|
||||
assert result["type"] == FlowResultType.FORM
|
||||
assert result["step_id"] == SOURCE_USER
|
||||
|
||||
result = await hass.config_entries.flow.async_configure(
|
||||
|
||||
@@ -580,7 +580,6 @@ async def test_bug_508(
|
||||
# "temperature": 17.5,
|
||||
"target_temp_high": 10,
|
||||
"target_temp_low": 10,
|
||||
"temperature": 10,
|
||||
},
|
||||
),
|
||||
]
|
||||
@@ -604,7 +603,6 @@ async def test_bug_508(
|
||||
"entity_id": "climate.mock_climate",
|
||||
"target_temp_high": 31,
|
||||
"target_temp_low": 31,
|
||||
"temperature": 31,
|
||||
},
|
||||
),
|
||||
]
|
||||
|
||||
Reference in New Issue