Compare commits
3 Commits
6.8.0.beta
...
6.8.0
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
3529607948 | ||
|
|
0a658b7a2a | ||
|
|
289ccc7bb7 |
1699
README-fr.md
210
README.md
@@ -4,6 +4,8 @@
|
||||
[![hacs][hacs_badge]][hacs]
|
||||
[![BuyMeCoffee][buymecoffeebadge]][buymecoffee]
|
||||
|
||||
[En](README.md)|[Fr](README-fr.md)
|
||||
|
||||

|
||||
|
||||
>  This thermostat integration aims to drastically simplify your automations around climate management. Because all classical events in climate are natively handled by the thermostat (nobody at home ?, activity detected in a room ?, window open ?, power shedding ?), you don't have to build over complicated scripts and automations to manage your climates ;-).
|
||||
@@ -28,7 +30,6 @@
|
||||
- [For a ```thermostat_over_switch``` type thermostat](#for-a-thermostat_over_switch-type-thermostat)
|
||||
- [For a thermostat of type ```thermostat_over_climate```:](#for-a-thermostat-of-type-thermostat_over_climate)
|
||||
- [Self-regulation](#self-regulation)
|
||||
- [Self-regulation in Expert mode](#self-regulation-in-expert-mode)
|
||||
- [Internal temperature compensation](#internal-temperature-compensation)
|
||||
- [synthesis of the self-regulation algorithm](#synthesis-of-the-self-regulation-algorithm)
|
||||
- [Auto-fan mode](#auto-fan-mode)
|
||||
@@ -49,6 +50,9 @@
|
||||
- [How to find the right service?](#how-to-find-the-right-service)
|
||||
- [The events](#the-events)
|
||||
- [Warning](#warning)
|
||||
- [Expert Mode Settings](#expert-mode-settings)
|
||||
- [Self-regulation in Expert mode](#self-regulation-in-expert-mode)
|
||||
- [On Time Clamping (max\_on\_percent)](#on-time-clamping-max_on_percent)
|
||||
- [Parameter summary](#parameter-summary)
|
||||
- [Tuning examples](#tuning-examples)
|
||||
- [Electrical heater](#electrical-heater)
|
||||
@@ -389,82 +393,6 @@ These three parameters make it possible to modulate the regulation and avoid mul
|
||||
|
||||
Self-regulation consists of forcing the equipment to go further by forcing its set temperature regularly. Its consumption can therefore be increased, as well as its wear.
|
||||
|
||||
#### Self-regulation in Expert mode
|
||||
|
||||
In **Expert** mode you can finely adjust the auto-regulation parameters to achieve your objectives and optimize as best as possible. The algorithm calculates the difference between the setpoint and the actual temperature of the room. This discrepancy is called error.
|
||||
The adjustable parameters are as follows:
|
||||
1. `kp`: the factor applied to the raw error,
|
||||
2. `ki`: the factor applied to the accumulation of errors,
|
||||
3. `k_ext`: the factor applied to the difference between the interior temperature and the exterior temperature,
|
||||
4. `offset_max`: the maximum correction (offset) that the regulation can apply,
|
||||
5. `stabilization_threshold`: a stabilization threshold which, when reached by the error, resets the accumulation of errors to 0,
|
||||
6. `accumulated_error_threshold`: the maximum for error accumulation.
|
||||
|
||||
For tuning, these observations must be taken into account:
|
||||
1. `kp * error` will give the offset linked to the raw error. This offset is directly proportional to the error and will be 0 when the target is reached,
|
||||
2. the accumulation of the error makes it possible to correct the stabilization of the curve while there remains an error. The error accumulates and the offset therefore gradually increases which should eventually stabilize at the target temperature. For this fundamental parameter to have an effect it must not be too small. An average value is 30
|
||||
3. `ki * accumulated_error_threshold` will give the maximum offset linked to the accumulation of the error,
|
||||
4. `k_ext` allows a correction to be applied immediately (without waiting for errors to accumulate) when the outside temperature is very different from the target temperature. If the stabilization is done too high when the temperature differences are significant, it is because this parameter is too high. It should be possible to cancel completely to let the first 2 offsets take place
|
||||
|
||||
The pre-programmed values are as follows:
|
||||
|
||||
Slow régulation :
|
||||
|
||||
kp: 0.2 # 20% of the current internal regulation offset are caused by the current difference of target temperature and room temperature
|
||||
ki: 0.8 / 288.0 # 80% of the current internal regulation offset are caused by the average offset of the past 24 hours
|
||||
k_ext: 1.0 / 25.0 # this will add 1°C to the offset when it's 25°C colder outdoor than indoor
|
||||
offset_max: 2.0 # limit to a final offset of -2°C to +2°C
|
||||
stabilization_threshold: 0.0 # this needs to be disabled as otherwise the long term accumulated error will always be reset when the temp briefly crosses from/to below/above the target
|
||||
accumulated_error_threshold: 2.0 * 288 # this allows up to 2°C long term offset in both directions
|
||||
|
||||
Light régulation :
|
||||
|
||||
kp: 0.2
|
||||
ki: 0.05
|
||||
k_ext: 0.05
|
||||
offset_max: 1.5
|
||||
stabilization_threshold: 0.1
|
||||
accumulated_error_threshold: 10
|
||||
|
||||
Medium régulation :
|
||||
|
||||
kp: 0.3
|
||||
ki: 0.05
|
||||
k_ext: 0.1
|
||||
offset_max: 2
|
||||
stabilization_threshold: 0.1
|
||||
accumulated_error_threshold: 20
|
||||
|
||||
Strong régulation :
|
||||
|
||||
"""Strong parameters for regulation
|
||||
A set of parameters which doesn't take into account the external temp
|
||||
and concentrate to internal temp error + accumulated error.
|
||||
This should work for cold external conditions which else generates
|
||||
high external_offset"""
|
||||
|
||||
kp: 0.4
|
||||
ki: 0.08
|
||||
k_ext: 0.0
|
||||
offset_max: 5
|
||||
stabilization_threshold: 0.1
|
||||
accumulated_error_threshold: 50
|
||||
|
||||
To use Expert mode you must declare the values you want to use for each of these parameters in your `configuration.yaml` in the following form:
|
||||
```
|
||||
versatile_thermostat:
|
||||
auto_regulation_expert:
|
||||
kp: 0.4
|
||||
ki: 0.08
|
||||
k_ext: 0.0
|
||||
offset_max: 5
|
||||
stabilization_threshold: 0.1
|
||||
accumulated_error_threshold: 50
|
||||
```
|
||||
and of course, configure the VTherm's self-regulation mode in **Expert** mode. All VTherms in Expert mode will use these same settings.
|
||||
|
||||
For the changes to be taken into account, you must either **completely restart Home Assistant** or just the **Versatile Thermostat integration** (Dev tools / Yaml / reloading the configuration / Versatile Thermostat).
|
||||
|
||||
#### Internal temperature compensation
|
||||
Sometimes, a device’s internal temperature sensor (like in a TRV or AC) can give inaccurate readings, especially if it’s too close to a heat source. This can cause the device to stop heating too soon.
|
||||
For example:
|
||||
@@ -800,6 +728,113 @@ context:
|
||||
>  _*Notes*_
|
||||
> Controlling a central boiler using software or hardware such as home automation can pose risks to its proper functioning. Before using these functions, make sure that your boiler has safety functions and that they are working. Turning on a boiler if all the taps are closed can generate excess pressure, for example.
|
||||
|
||||
|
||||
## Expert Mode Settings
|
||||
|
||||
Expert Mode settings refer to Settings made in the Home Assistant `configuration.yaml` file under the `versatile_thermostat` section. You might have to add this section by yourself to the `configuration.yaml` file.
|
||||
|
||||
These settings are meant to be used only in **specific niche cases and with careful considerations**.
|
||||
|
||||
|
||||
The following sections describe the available export mode settings in detail with examples on how to configure them. Be aware that these settings require a **complete restart** of Home Assistant or a **reload of Versatile Thermostat integration** (Dev tools / Yaml / reloading the configuration / Versatile Thermostat) to take effect.
|
||||
|
||||
|
||||
### Self-regulation in Expert mode
|
||||
|
||||
In **Expert** mode you can finely adjust the auto-regulation parameters to achieve your objectives and optimize as best as possible. The algorithm calculates the difference between the setpoint and the actual temperature of the room. This discrepancy is called error.
|
||||
The adjustable parameters are as follows:
|
||||
1. `kp`: the factor applied to the raw error,
|
||||
2. `ki`: the factor applied to the accumulation of errors,
|
||||
3. `k_ext`: the factor applied to the difference between the interior temperature and the exterior temperature,
|
||||
4. `offset_max`: the maximum correction (offset) that the regulation can apply,
|
||||
5. `stabilization_threshold`: a stabilization threshold which, when reached by the error, resets the accumulation of errors to 0,
|
||||
6. `accumulated_error_threshold`: the maximum for error accumulation.
|
||||
|
||||
For tuning, these observations must be taken into account:
|
||||
1. `kp * error` will give the offset linked to the raw error. This offset is directly proportional to the error and will be 0 when the target is reached,
|
||||
2. the accumulation of the error makes it possible to correct the stabilization of the curve while there remains an error. The error accumulates and the offset therefore gradually increases which should eventually stabilize at the target temperature. For this fundamental parameter to have an effect it must not be too small. An average value is 30
|
||||
3. `ki * accumulated_error_threshold` will give the maximum offset linked to the accumulation of the error,
|
||||
4. `k_ext` allows a correction to be applied immediately (without waiting for errors to accumulate) when the outside temperature is very different from the target temperature. If the stabilization is done too high when the temperature differences are significant, it is because this parameter is too high. It should be possible to cancel completely to let the first 2 offsets take place
|
||||
|
||||
The pre-programmed values are as follows:
|
||||
|
||||
Slow régulation :
|
||||
|
||||
kp: 0.2 # 20% of the current internal regulation offset are caused by the current difference of target temperature and room temperature
|
||||
ki: 0.8 / 288.0 # 80% of the current internal regulation offset are caused by the average offset of the past 24 hours
|
||||
k_ext: 1.0 / 25.0 # this will add 1°C to the offset when it's 25°C colder outdoor than indoor
|
||||
offset_max: 2.0 # limit to a final offset of -2°C to +2°C
|
||||
stabilization_threshold: 0.0 # this needs to be disabled as otherwise the long term accumulated error will always be reset when the temp briefly crosses from/to below/above the target
|
||||
accumulated_error_threshold: 2.0 * 288 # this allows up to 2°C long term offset in both directions
|
||||
|
||||
Light régulation :
|
||||
|
||||
kp: 0.2
|
||||
ki: 0.05
|
||||
k_ext: 0.05
|
||||
offset_max: 1.5
|
||||
stabilization_threshold: 0.1
|
||||
accumulated_error_threshold: 10
|
||||
|
||||
Medium régulation :
|
||||
|
||||
kp: 0.3
|
||||
ki: 0.05
|
||||
k_ext: 0.1
|
||||
offset_max: 2
|
||||
stabilization_threshold: 0.1
|
||||
accumulated_error_threshold: 20
|
||||
|
||||
Strong régulation :
|
||||
|
||||
"""Strong parameters for regulation
|
||||
A set of parameters which doesn't take into account the external temp
|
||||
and concentrate to internal temp error + accumulated error.
|
||||
This should work for cold external conditions which else generates
|
||||
high external_offset"""
|
||||
|
||||
kp: 0.4
|
||||
ki: 0.08
|
||||
k_ext: 0.0
|
||||
offset_max: 5
|
||||
stabilization_threshold: 0.1
|
||||
accumulated_error_threshold: 50
|
||||
|
||||
To use Expert mode you must declare the values you want to use for each of these parameters in your `configuration.yaml` in the following form:
|
||||
```
|
||||
versatile_thermostat:
|
||||
auto_regulation_expert:
|
||||
kp: 0.4
|
||||
ki: 0.08
|
||||
k_ext: 0.0
|
||||
offset_max: 5
|
||||
stabilization_threshold: 0.1
|
||||
accumulated_error_threshold: 50
|
||||
```
|
||||
and of course, configure the VTherm's self-regulation mode in **Expert** mode. All VTherms in Expert mode will use these same settings.
|
||||
|
||||
For the changes to be taken into account, you must either **completely restart Home Assistant** or just the **Versatile Thermostat integration** (Dev tools / Yaml / reloading the configuration / Versatile Thermostat).
|
||||
|
||||
|
||||
### On Time Clamping (max_on_percent)
|
||||
|
||||
|
||||
The calculated on time percent can be limited to a maximum percentage of the cycle duration. This setting has to be made in expert mode and will be used for all Versatile Thermostats.
|
||||
|
||||
```
|
||||
versatile_thermostat:
|
||||
max_on_percent: 0.8
|
||||
```
|
||||
|
||||
The example above limits the maximum ON time to 80% (0.8) of the cycle length. If the cycle length is for example 600 seconds (10min), the maximum ON time will be limited to 480 seconds (8min). The remaining 120 seconds of the cycle will always remain in the OFF state.
|
||||
|
||||
There are three debug attributes of interest regarding this feature:
|
||||
|
||||
* `max_on_percent` # clamping setting as configured in expert mode
|
||||
* `calculated_on_percent` # calculated on percent without clamping applied
|
||||
* `on_percent` # used on percent with clamping applied
|
||||
|
||||
|
||||
<details>
|
||||
<summary>Parameter summary</summary>
|
||||
|
||||
@@ -1248,9 +1283,13 @@ Replace values in [[ ]] by yours.
|
||||
yaxis: y1
|
||||
name: Ema
|
||||
- entity: '[[climate]]'
|
||||
attribute: regulated_target_temperature
|
||||
yaxis: y1
|
||||
name: Regulated T°
|
||||
attribute: on_percent
|
||||
yaxis: y2
|
||||
name: Power percent
|
||||
fill: tozeroy
|
||||
fillcolor: rgba(200, 10, 10, 0.3)
|
||||
line:
|
||||
color: rgba(200, 10, 10, 0.9)
|
||||
- entity: '[[slope]]'
|
||||
name: Slope
|
||||
fill: tozeroy
|
||||
@@ -1275,12 +1314,19 @@ Replace values in [[ ]] by yours.
|
||||
yaxis:
|
||||
visible: true
|
||||
position: 0
|
||||
yaxis2:
|
||||
visible: true
|
||||
position: 0
|
||||
fixedrange: true
|
||||
range:
|
||||
- 0
|
||||
- 1
|
||||
yaxis9:
|
||||
visible: true
|
||||
fixedrange: false
|
||||
range:
|
||||
- -0.5
|
||||
- 0.5
|
||||
- -2
|
||||
- 2
|
||||
position: 1
|
||||
xaxis:
|
||||
rangeselector:
|
||||
|
||||
@@ -54,6 +54,7 @@ from .const import (
|
||||
CONF_THERMOSTAT_SWITCH,
|
||||
CONF_THERMOSTAT_CLIMATE,
|
||||
CONF_THERMOSTAT_VALVE,
|
||||
CONF_MAX_ON_PERCENT,
|
||||
)
|
||||
|
||||
from .vtherm_api import VersatileThermostatAPI
|
||||
@@ -86,6 +87,7 @@ CONFIG_SCHEMA = vol.Schema(
|
||||
CONF_AUTO_REGULATION_EXPERT: vol.Schema(SELF_REGULATION_PARAM_SCHEMA),
|
||||
CONF_SHORT_EMA_PARAMS: vol.Schema(EMA_PARAM_SCHEMA),
|
||||
CONF_SAFETY_MODE: vol.Schema(SAFETY_MODE_PARAM_SCHEMA),
|
||||
vol.Optional(CONF_MAX_ON_PERCENT): vol.Coerce(float),
|
||||
}
|
||||
),
|
||||
},
|
||||
|
||||
@@ -9,7 +9,6 @@ from datetime import timedelta, datetime
|
||||
from types import MappingProxyType
|
||||
from typing import Any, TypeVar, Generic
|
||||
|
||||
from homeassistant.util import dt as dt_util
|
||||
from homeassistant.core import (
|
||||
HomeAssistant,
|
||||
callback,
|
||||
@@ -80,13 +79,6 @@ _LOGGER = logging.getLogger(__name__)
|
||||
ConfigData = MappingProxyType[str, Any]
|
||||
T = TypeVar("T", bound=UnderlyingEntity)
|
||||
|
||||
|
||||
def get_tz(hass: HomeAssistant):
|
||||
"""Get the current timezone"""
|
||||
|
||||
return dt_util.get_time_zone(hass.config.time_zone)
|
||||
|
||||
|
||||
class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"""Representation of a base class for all Versatile Thermostat device."""
|
||||
|
||||
@@ -135,9 +127,12 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"max_power_sensor_entity_id",
|
||||
"temperature_unit",
|
||||
"is_device_active",
|
||||
"nb_device_actives",
|
||||
"target_temperature_step",
|
||||
"is_used_by_central_boiler",
|
||||
"temperature_slope"
|
||||
"temperature_slope",
|
||||
"max_on_percent",
|
||||
"have_valve_regulation",
|
||||
}
|
||||
)
|
||||
)
|
||||
@@ -459,8 +454,8 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
else DEFAULT_SECURITY_DEFAULT_ON_PERCENT
|
||||
)
|
||||
self._minimal_activation_delay = entry_infos.get(CONF_MINIMAL_ACTIVATION_DELAY)
|
||||
self._last_temperature_measure = datetime.now(tz=self._current_tz)
|
||||
self._last_ext_temperature_measure = datetime.now(tz=self._current_tz)
|
||||
self._last_temperature_measure = self.now
|
||||
self._last_ext_temperature_measure = self.now
|
||||
self._security_state = False
|
||||
|
||||
# Initiate the ProportionalAlgorithm
|
||||
@@ -503,6 +498,8 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
entry_infos.get(CONF_WINDOW_ACTION) or CONF_WINDOW_TURN_OFF
|
||||
)
|
||||
|
||||
self._max_on_percent = api.max_on_percent
|
||||
|
||||
_LOGGER.debug(
|
||||
"%s - Creation of a new VersatileThermostat entity: unique_id=%s",
|
||||
self,
|
||||
@@ -999,6 +996,15 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
return True
|
||||
return False
|
||||
|
||||
@property
|
||||
def nb_device_actives(self) -> int:
|
||||
"""Calculate the number of active devices"""
|
||||
ret = 0
|
||||
for under in self._underlyings:
|
||||
if under.is_device_active:
|
||||
ret += 1
|
||||
return ret
|
||||
|
||||
@property
|
||||
def current_temperature(self) -> float | None:
|
||||
"""Return the sensor temperature."""
|
||||
@@ -1126,6 +1132,11 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"""Returns the underlying entities"""
|
||||
return self._underlyings
|
||||
|
||||
@property
|
||||
def activable_underlying_entities(self) -> list | None:
|
||||
"""Returns the activable underlying entities for controling the central boiler"""
|
||||
return self.underlying_entities
|
||||
|
||||
def find_underlying_by_entity_id(self, entity_id: str) -> Entity | None:
|
||||
"""Get the underlying entity by a entity_id"""
|
||||
for under in self._underlyings:
|
||||
@@ -1339,7 +1350,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
self, old_preset_mode: str | None = None
|
||||
): # pylint: disable=unused-argument
|
||||
"""Reset to now the last change time"""
|
||||
self._last_change_time = datetime.now(tz=self._current_tz)
|
||||
self._last_change_time = self.now
|
||||
_LOGGER.debug("%s - last_change_time is now %s", self, self._last_change_time)
|
||||
|
||||
def reset_last_temperature_time(self, old_preset_mode: str | None = None):
|
||||
@@ -1349,7 +1360,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
and old_preset_mode not in HIDDEN_PRESETS
|
||||
):
|
||||
self._last_temperature_measure = self._last_ext_temperature_measure = (
|
||||
datetime.now(tz=self._current_tz)
|
||||
self.now
|
||||
)
|
||||
|
||||
def find_preset_temp(self, preset_mode: str):
|
||||
@@ -1382,7 +1393,10 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
)
|
||||
|
||||
if motion_preset in self._presets:
|
||||
return self._presets[motion_preset]
|
||||
if self._presence_on and self.presence_state in [STATE_OFF, None]:
|
||||
return self._presets_away[motion_preset + PRESET_AWAY_SUFFIX]
|
||||
else:
|
||||
return self._presets[motion_preset]
|
||||
else:
|
||||
return None
|
||||
else:
|
||||
@@ -1452,16 +1466,16 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"""Extract the last_changed state from State or return now if not available"""
|
||||
return (
|
||||
state.last_changed.astimezone(self._current_tz)
|
||||
if state.last_changed is not None
|
||||
else datetime.now(tz=self._current_tz)
|
||||
if isinstance(state.last_changed, datetime)
|
||||
else self.now
|
||||
)
|
||||
|
||||
def get_last_updated_date_or_now(self, state: State) -> datetime:
|
||||
"""Extract the last_changed state from State or return now if not available"""
|
||||
return (
|
||||
state.last_updated.astimezone(self._current_tz)
|
||||
if state.last_updated is not None
|
||||
else datetime.now(tz=self._current_tz)
|
||||
if isinstance(state.last_updated, datetime)
|
||||
else self.now
|
||||
)
|
||||
|
||||
@callback
|
||||
@@ -1903,7 +1917,12 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
STATE_NOT_HOME,
|
||||
):
|
||||
return
|
||||
if self._attr_preset_mode not in [PRESET_BOOST, PRESET_COMFORT, PRESET_ECO]:
|
||||
if self._attr_preset_mode not in [
|
||||
PRESET_BOOST,
|
||||
PRESET_COMFORT,
|
||||
PRESET_ECO,
|
||||
PRESET_ACTIVITY,
|
||||
]:
|
||||
return
|
||||
|
||||
new_temp = self.find_preset_temp(self.preset_mode)
|
||||
@@ -1993,7 +2012,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
if in_cycle:
|
||||
slope = self._window_auto_algo.check_age_last_measurement(
|
||||
temperature=self._ema_temp,
|
||||
datetime_now=datetime.now(get_tz(self._hass)),
|
||||
datetime_now=self.now,
|
||||
)
|
||||
else:
|
||||
slope = self._window_auto_algo.add_temp_measurement(
|
||||
@@ -2281,10 +2300,11 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
@property
|
||||
def now(self) -> datetime:
|
||||
"""Get now. The local datetime or the overloaded _set_now date"""
|
||||
return self._now if self._now is not None else datetime.now(self._current_tz)
|
||||
return self._now if self._now is not None else NowClass.get_now(self._hass)
|
||||
|
||||
async def check_safety(self) -> bool:
|
||||
"""Check if last temperature date is too long"""
|
||||
|
||||
now = self.now
|
||||
delta_temp = (
|
||||
now - self._last_temperature_measure.replace(tzinfo=self._current_tz)
|
||||
@@ -2480,7 +2500,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
)
|
||||
else:
|
||||
_LOGGER.info(
|
||||
"%s - Window is open. Set hvac_mode to '%s'", self, HVACMode.OFF
|
||||
"%s - Window is open. Apply window action %s", self, self._window_action
|
||||
)
|
||||
if self._window_action == CONF_WINDOW_TURN_OFF and not self.is_on:
|
||||
_LOGGER.debug(
|
||||
@@ -2652,16 +2672,17 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"device_power": self._device_power,
|
||||
ATTR_MEAN_POWER_CYCLE: self.mean_cycle_power,
|
||||
ATTR_TOTAL_ENERGY: self.total_energy,
|
||||
"last_update_datetime": datetime.now()
|
||||
.astimezone(self._current_tz)
|
||||
.isoformat(),
|
||||
"last_update_datetime": self.now.isoformat(),
|
||||
"timezone": str(self._current_tz),
|
||||
"temperature_unit": self.temperature_unit,
|
||||
"is_device_active": self.is_device_active,
|
||||
"nb_device_actives": self.nb_device_actives,
|
||||
"ema_temp": self._ema_temp,
|
||||
"is_used_by_central_boiler": self.is_used_by_central_boiler,
|
||||
"temperature_slope": round(self.last_temperature_slope or 0, 3),
|
||||
"hvac_off_reason": self.hvac_off_reason,
|
||||
"max_on_percent": self._max_on_percent,
|
||||
"have_valve_regulation": self.have_valve_regulation,
|
||||
}
|
||||
|
||||
_LOGGER.debug(
|
||||
@@ -2680,6 +2701,11 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
)
|
||||
return super().async_write_ha_state()
|
||||
|
||||
@property
|
||||
def have_valve_regulation(self) -> bool:
|
||||
"""True if the Thermostat is regulated by valve"""
|
||||
return False
|
||||
|
||||
@callback
|
||||
def async_registry_entry_updated(self):
|
||||
"""update the entity if the config entry have been updated
|
||||
|
||||
@@ -108,7 +108,7 @@ class SecurityBinarySensor(VersatileThermostatBaseEntity, BinarySensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
old_state = self._attr_is_on
|
||||
self._attr_is_on = self.my_climate.security_state is True
|
||||
@@ -147,7 +147,7 @@ class OverpoweringBinarySensor(VersatileThermostatBaseEntity, BinarySensorEntity
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
old_state = self._attr_is_on
|
||||
self._attr_is_on = self.my_climate.overpowering_state is True
|
||||
@@ -186,7 +186,7 @@ class WindowBinarySensor(VersatileThermostatBaseEntity, BinarySensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
old_state = self._attr_is_on
|
||||
# Issue 120 - only take defined presence value
|
||||
@@ -236,7 +236,7 @@ class MotionBinarySensor(VersatileThermostatBaseEntity, BinarySensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
old_state = self._attr_is_on
|
||||
# Issue 120 - only take defined presence value
|
||||
if self.my_climate.motion_state in [STATE_ON, STATE_OFF]:
|
||||
@@ -277,7 +277,7 @@ class PresenceBinarySensor(VersatileThermostatBaseEntity, BinarySensorEntity):
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
old_state = self._attr_is_on
|
||||
# Issue 120 - only take defined presence value
|
||||
if self.my_climate.presence_state in [STATE_ON, STATE_OFF]:
|
||||
@@ -317,7 +317,7 @@ class WindowByPassBinarySensor(VersatileThermostatBaseEntity, BinarySensorEntity
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
old_state = self._attr_is_on
|
||||
if self.my_climate.window_bypass_state in [True, False]:
|
||||
self._attr_is_on = self.my_climate.window_bypass_state
|
||||
|
||||
@@ -22,28 +22,12 @@ from homeassistant.const import (
|
||||
STATE_NOT_HOME,
|
||||
)
|
||||
|
||||
from .const import (
|
||||
DOMAIN,
|
||||
PLATFORMS,
|
||||
CONF_PRESETS_WITH_AC,
|
||||
SERVICE_SET_PRESENCE,
|
||||
SERVICE_SET_PRESET_TEMPERATURE,
|
||||
SERVICE_SET_SECURITY,
|
||||
SERVICE_SET_WINDOW_BYPASS,
|
||||
SERVICE_SET_AUTO_REGULATION_MODE,
|
||||
SERVICE_SET_AUTO_FAN_MODE,
|
||||
CONF_THERMOSTAT_TYPE,
|
||||
CONF_THERMOSTAT_SWITCH,
|
||||
CONF_THERMOSTAT_CLIMATE,
|
||||
CONF_THERMOSTAT_VALVE,
|
||||
CONF_THERMOSTAT_CENTRAL_CONFIG,
|
||||
CONF_SONOFF_TRZB_MODE,
|
||||
)
|
||||
from .const import * # pylint: disable=wildcard-import,unused-wildcard-import
|
||||
|
||||
from .thermostat_switch import ThermostatOverSwitch
|
||||
from .thermostat_climate import ThermostatOverClimate
|
||||
from .thermostat_valve import ThermostatOverValve
|
||||
from .thermostat_sonoff_trvzb import ThermostatOverSonoffTRVZB
|
||||
from .thermostat_climate_valve import ThermostatOverClimateValve
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
@@ -62,7 +46,9 @@ async def async_setup_entry(
|
||||
unique_id = entry.entry_id
|
||||
name = entry.data.get(CONF_NAME)
|
||||
vt_type = entry.data.get(CONF_THERMOSTAT_TYPE)
|
||||
is_sonoff_trvzb = entry.data.get(CONF_SONOFF_TRZB_MODE)
|
||||
have_valve_regulation = (
|
||||
entry.data.get(CONF_AUTO_REGULATION_MODE) == CONF_AUTO_REGULATION_VALVE
|
||||
)
|
||||
|
||||
if vt_type == CONF_THERMOSTAT_CENTRAL_CONFIG:
|
||||
return
|
||||
@@ -72,8 +58,8 @@ async def async_setup_entry(
|
||||
if vt_type == CONF_THERMOSTAT_SWITCH:
|
||||
entity = ThermostatOverSwitch(hass, unique_id, name, entry.data)
|
||||
elif vt_type == CONF_THERMOSTAT_CLIMATE:
|
||||
if is_sonoff_trvzb is True:
|
||||
entity = ThermostatOverSonoffTRVZB(hass, unique_id, name, entry.data)
|
||||
if have_valve_regulation is True:
|
||||
entity = ThermostatOverClimateValve(hass, unique_id, name, entry.data)
|
||||
else:
|
||||
entity = ThermostatOverClimate(hass, unique_id, name, entry.data)
|
||||
elif vt_type == CONF_THERMOSTAT_VALVE:
|
||||
|
||||
@@ -3,38 +3,20 @@
|
||||
# pylint: disable=line-too-long
|
||||
|
||||
import logging
|
||||
from datetime import timedelta, datetime
|
||||
from datetime import timedelta
|
||||
from homeassistant.core import HomeAssistant, callback, Event
|
||||
from homeassistant.components.climate import ClimateEntity, DOMAIN as CLIMATE_DOMAIN
|
||||
from homeassistant.helpers.entity_component import EntityComponent
|
||||
from homeassistant.helpers.entity import Entity
|
||||
from homeassistant.helpers.device_registry import DeviceInfo, DeviceEntryType
|
||||
from homeassistant.helpers.event import async_track_state_change_event, async_call_later
|
||||
from homeassistant.util import dt as dt_util
|
||||
|
||||
|
||||
from .base_thermostat import BaseThermostat
|
||||
from .const import DOMAIN, DEVICE_MANUFACTURER, ServiceConfigurationError
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
def get_tz(hass: HomeAssistant):
|
||||
"""Get the current timezone"""
|
||||
|
||||
return dt_util.get_time_zone(hass.config.time_zone)
|
||||
|
||||
|
||||
class NowClass:
|
||||
"""For testing purpose only"""
|
||||
|
||||
@staticmethod
|
||||
def get_now(hass: HomeAssistant) -> datetime:
|
||||
"""A test function to get the now.
|
||||
For testing purpose this method can be overriden to get a specific
|
||||
timestamp.
|
||||
"""
|
||||
return datetime.now(get_tz(hass))
|
||||
|
||||
|
||||
def round_to_nearest(n: float, x: float) -> float:
|
||||
"""Round a number to the nearest x (which should be decimal but not null)
|
||||
Example:
|
||||
|
||||
@@ -29,27 +29,6 @@ COMES_FROM = "comes_from"
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
|
||||
# Not used but can be useful in other context
|
||||
# def schema_defaults(schema, **defaults):
|
||||
# """Create a new schema with default values filled in."""
|
||||
# copy = schema.extend({})
|
||||
# for field, field_type in copy.schema.items():
|
||||
# if isinstance(field_type, vol.In):
|
||||
# value = None
|
||||
#
|
||||
# if value in field_type.container:
|
||||
# # field.default = vol.default_factory(value)
|
||||
# field.description = {"suggested_value": value}
|
||||
# continue
|
||||
#
|
||||
# if field.schema in defaults:
|
||||
# # field.default = vol.default_factory(defaults[field])
|
||||
# field.description = {"suggested_value": defaults[field]}
|
||||
# return copy
|
||||
#
|
||||
|
||||
|
||||
def add_suggested_values_to_schema(
|
||||
data_schema: vol.Schema, suggested_values: Mapping[str, Any]
|
||||
) -> vol.Schema:
|
||||
@@ -77,7 +56,6 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
VERSION = CONFIG_VERSION
|
||||
MINOR_VERSION = CONFIG_MINOR_VERSION
|
||||
|
||||
_infos: dict
|
||||
_placeholders = {
|
||||
CONF_NAME: "",
|
||||
}
|
||||
@@ -85,7 +63,7 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
def __init__(self, infos) -> None:
|
||||
super().__init__()
|
||||
_LOGGER.debug("CTOR BaseConfigFlow infos: %s", infos)
|
||||
self._infos = infos
|
||||
self._infos: dict = infos
|
||||
|
||||
# VTherm API should have been initialized before arriving here
|
||||
vtherm_api = VersatileThermostatAPI.get_vtherm_api()
|
||||
@@ -94,8 +72,8 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
else:
|
||||
self._central_config = None
|
||||
|
||||
self._init_feature_flags(infos)
|
||||
self._init_central_config_flags(infos)
|
||||
self._init_feature_flags(infos)
|
||||
|
||||
def _init_feature_flags(self, _):
|
||||
"""Fix features selection depending to infos"""
|
||||
@@ -162,21 +140,40 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
if COMES_FROM in self._infos:
|
||||
del self._infos[COMES_FROM]
|
||||
|
||||
def check_sonoff_trvzb_nb_entities(self, data: dict) -> bool:
|
||||
"""Check the number of entities for Sonoff TRVZB"""
|
||||
def is_valve_regulation_selected(self, infos) -> bool:
|
||||
"""True of the valve regulation mode is selected"""
|
||||
return infos.get(CONF_AUTO_REGULATION_MODE, None) == CONF_AUTO_REGULATION_VALVE
|
||||
|
||||
def check_valve_regulation_nb_entities(self, data: dict, step_id=None) -> bool:
|
||||
"""Check the number of entities for Valve regulation"""
|
||||
if step_id not in ["type", "valve_regulation", "check_complete"]:
|
||||
return True
|
||||
|
||||
underlyings_to_check = data if step_id == "type" else self._infos
|
||||
# underlyings_to_check = self._infos # data if step_id == "type" else self._infos
|
||||
regulation_infos_to_check = (
|
||||
data if step_id == "valve_regulation" else self._infos
|
||||
)
|
||||
|
||||
ret = True
|
||||
if (
|
||||
self._infos.get(CONF_SONOFF_TRZB_MODE)
|
||||
and data.get(CONF_OFFSET_CALIBRATION_LIST) is not None
|
||||
self.is_valve_regulation_selected(underlyings_to_check)
|
||||
and step_id != "type"
|
||||
):
|
||||
nb_unders = len(self._infos.get(CONF_UNDERLYING_LIST))
|
||||
nb_offset = len(data.get(CONF_OFFSET_CALIBRATION_LIST))
|
||||
nb_opening = len(data.get(CONF_OPENING_DEGREE_LIST))
|
||||
nb_closing = len(data.get(CONF_CLOSING_DEGREE_LIST))
|
||||
nb_unders = len(underlyings_to_check.get(CONF_UNDERLYING_LIST))
|
||||
nb_offset = len(
|
||||
regulation_infos_to_check.get(CONF_OFFSET_CALIBRATION_LIST, [])
|
||||
)
|
||||
nb_opening = len(
|
||||
regulation_infos_to_check.get(CONF_OPENING_DEGREE_LIST, [])
|
||||
)
|
||||
nb_closing = len(
|
||||
regulation_infos_to_check.get(CONF_CLOSING_DEGREE_LIST, [])
|
||||
)
|
||||
if (
|
||||
nb_unders != nb_offset
|
||||
or nb_unders != nb_opening
|
||||
or nb_unders != nb_closing
|
||||
nb_unders != nb_opening
|
||||
or (nb_unders != nb_offset and nb_offset > 0)
|
||||
or (nb_unders != nb_closing and nb_closing > 0)
|
||||
):
|
||||
ret = False
|
||||
return ret
|
||||
@@ -259,8 +256,8 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
|
||||
# Check that the number of offet_calibration and opening_degree and closing_degree are equals
|
||||
# to the number of underlying entities
|
||||
if not self.check_sonoff_trvzb_nb_entities(data):
|
||||
raise SonoffTRVZBNbEntitiesIncorrect()
|
||||
if not self.check_valve_regulation_nb_entities(data, step_id):
|
||||
raise ValveRegulationNbEntitiesIncorrect()
|
||||
|
||||
def check_config_complete(self, infos) -> bool:
|
||||
"""True if the config is now complete (ie all mandatory attributes are set)"""
|
||||
@@ -357,7 +354,7 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
):
|
||||
return False
|
||||
|
||||
if not self.check_sonoff_trvzb_nb_entities(infos):
|
||||
if not self.check_valve_regulation_nb_entities(infos, "check_complete"):
|
||||
return False
|
||||
|
||||
return True
|
||||
@@ -400,8 +397,8 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
errors[str(err)] = "service_configuration_format"
|
||||
except ConfigurationNotCompleteError as err:
|
||||
errors["base"] = "configuration_not_complete"
|
||||
except SonoffTRVZBNbEntitiesIncorrect as err:
|
||||
errors["base"] = "sonoff_trvzb_nb_entities_incorrect"
|
||||
except ValveRegulationNbEntitiesIncorrect as err:
|
||||
errors["base"] = "valve_regulation_nb_entities_incorrect"
|
||||
except Exception: # pylint: disable=broad-except
|
||||
_LOGGER.exception("Unexpected exception")
|
||||
errors["base"] = "unknown"
|
||||
@@ -453,6 +450,7 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
if (
|
||||
self._infos.get(CONF_PROP_FUNCTION) == PROPORTIONAL_FUNCTION_TPI
|
||||
or is_central_config
|
||||
or self.is_valve_regulation_selected(self._infos)
|
||||
):
|
||||
menu_options.append("tpi")
|
||||
|
||||
@@ -488,8 +486,8 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
]:
|
||||
menu_options.append("auto_start_stop")
|
||||
|
||||
if self._infos.get(CONF_SONOFF_TRZB_MODE) is True:
|
||||
menu_options.append("sonoff_trvzb")
|
||||
if self.is_valve_regulation_selected(self._infos):
|
||||
menu_options.append("valve_regulation")
|
||||
|
||||
menu_options.append("advanced")
|
||||
|
||||
@@ -563,11 +561,10 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
if (
|
||||
self._infos[CONF_THERMOSTAT_TYPE] == CONF_THERMOSTAT_CLIMATE
|
||||
and user_input is not None
|
||||
and not user_input.get(CONF_SONOFF_TRZB_MODE)
|
||||
and not self.is_valve_regulation_selected(user_input)
|
||||
):
|
||||
# Remove TPI info
|
||||
for key in [
|
||||
PROPORTIONAL_FUNCTION_TPI,
|
||||
CONF_PROP_FUNCTION,
|
||||
CONF_TPI_COEF_INT,
|
||||
CONF_TPI_COEF_EXT,
|
||||
@@ -621,19 +618,21 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
|
||||
return await self.generic_step("auto_start_stop", schema, user_input, next_step)
|
||||
|
||||
async def async_step_sonoff_trvzb(
|
||||
async def async_step_valve_regulation(
|
||||
self, user_input: dict | None = None
|
||||
) -> FlowResult:
|
||||
"""Handle the Sonoff TRVZB configuration step"""
|
||||
"""Handle the valve regulation configuration step"""
|
||||
_LOGGER.debug(
|
||||
"Into ConfigFlow.async_step_sonoff_trvzb user_input=%s", user_input
|
||||
"Into ConfigFlow.async_step_valve_regulation user_input=%s", user_input
|
||||
)
|
||||
|
||||
schema = STEP_SONOFF_TRVZB
|
||||
schema = STEP_VALVE_REGULATION
|
||||
self._infos[COMES_FROM] = None
|
||||
next_step = self.async_step_menu
|
||||
|
||||
return await self.generic_step("sonoff_trvzb", schema, user_input, next_step)
|
||||
return await self.generic_step(
|
||||
"valve_regulation", schema, user_input, next_step
|
||||
)
|
||||
|
||||
async def async_step_tpi(self, user_input: dict | None = None) -> FlowResult:
|
||||
"""Handle the TPI flow steps"""
|
||||
|
||||
@@ -141,7 +141,6 @@ STEP_THERMOSTAT_CLIMATE = vol.Schema( # pylint: disable=invalid-name
|
||||
selector.EntitySelectorConfig(domain=CLIMATE_DOMAIN, multiple=True),
|
||||
),
|
||||
vol.Optional(CONF_AC_MODE, default=False): cv.boolean,
|
||||
vol.Optional(CONF_SONOFF_TRZB_MODE, default=False): cv.boolean,
|
||||
vol.Optional(
|
||||
CONF_AUTO_REGULATION_MODE, default=CONF_AUTO_REGULATION_NONE
|
||||
): selector.SelectSelector(
|
||||
@@ -198,19 +197,19 @@ STEP_AUTO_START_STOP = vol.Schema( # pylint: disable=invalid-name
|
||||
}
|
||||
)
|
||||
|
||||
STEP_SONOFF_TRVZB = vol.Schema( # pylint: disable=invalid-name
|
||||
STEP_VALVE_REGULATION = vol.Schema( # pylint: disable=invalid-name
|
||||
{
|
||||
vol.Required(CONF_OFFSET_CALIBRATION_LIST): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(
|
||||
domain=[NUMBER_DOMAIN, INPUT_NUMBER_DOMAIN], multiple=True
|
||||
),
|
||||
),
|
||||
vol.Required(CONF_OPENING_DEGREE_LIST): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(
|
||||
domain=[NUMBER_DOMAIN, INPUT_NUMBER_DOMAIN], multiple=True
|
||||
),
|
||||
),
|
||||
vol.Required(CONF_CLOSING_DEGREE_LIST): selector.EntitySelector(
|
||||
vol.Optional(CONF_OFFSET_CALIBRATION_LIST): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(
|
||||
domain=[NUMBER_DOMAIN, INPUT_NUMBER_DOMAIN], multiple=True
|
||||
),
|
||||
),
|
||||
vol.Optional(CONF_CLOSING_DEGREE_LIST): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(
|
||||
domain=[NUMBER_DOMAIN, INPUT_NUMBER_DOMAIN], multiple=True
|
||||
),
|
||||
|
||||
@@ -2,9 +2,12 @@
|
||||
"""Constants for the Versatile Thermostat integration."""
|
||||
|
||||
import logging
|
||||
import math
|
||||
from typing import Literal
|
||||
from datetime import datetime
|
||||
|
||||
from enum import Enum
|
||||
from homeassistant.core import HomeAssistant
|
||||
from homeassistant.const import CONF_NAME, Platform
|
||||
|
||||
from homeassistant.components.climate import (
|
||||
@@ -16,6 +19,7 @@ from homeassistant.components.climate import (
|
||||
)
|
||||
|
||||
from homeassistant.exceptions import HomeAssistantError
|
||||
from homeassistant.util import dt as dt_util
|
||||
|
||||
from .prop_algorithm import (
|
||||
PROPORTIONAL_FUNCTION_TPI,
|
||||
@@ -94,12 +98,12 @@ CONF_USE_POWER_FEATURE = "use_power_feature"
|
||||
CONF_USE_CENTRAL_BOILER_FEATURE = "use_central_boiler_feature"
|
||||
CONF_USE_AUTO_START_STOP_FEATURE = "use_auto_start_stop_feature"
|
||||
CONF_AC_MODE = "ac_mode"
|
||||
CONF_SONOFF_TRZB_MODE = "sonoff_trvzb_mode"
|
||||
CONF_WINDOW_AUTO_OPEN_THRESHOLD = "window_auto_open_threshold"
|
||||
CONF_WINDOW_AUTO_CLOSE_THRESHOLD = "window_auto_close_threshold"
|
||||
CONF_WINDOW_AUTO_MAX_DURATION = "window_auto_max_duration"
|
||||
CONF_AUTO_REGULATION_MODE = "auto_regulation_mode"
|
||||
CONF_AUTO_REGULATION_NONE = "auto_regulation_none"
|
||||
CONF_AUTO_REGULATION_VALVE = "auto_regulation_valve"
|
||||
CONF_AUTO_REGULATION_SLOW = "auto_regulation_slow"
|
||||
CONF_AUTO_REGULATION_LIGHT = "auto_regulation_light"
|
||||
CONF_AUTO_REGULATION_MEDIUM = "auto_regulation_medium"
|
||||
@@ -137,6 +141,7 @@ CONF_VALVE_4 = "valve_entity4_id"
|
||||
# Global params into configuration.yaml
|
||||
CONF_SHORT_EMA_PARAMS = "short_ema_params"
|
||||
CONF_SAFETY_MODE = "safety_mode"
|
||||
CONF_MAX_ON_PERCENT = "max_on_percent"
|
||||
|
||||
CONF_USE_MAIN_CENTRAL_CONFIG = "use_main_central_config"
|
||||
CONF_USE_TPI_CENTRAL_CONFIG = "use_tpi_central_config"
|
||||
@@ -291,7 +296,6 @@ ALL_CONF = (
|
||||
CONF_USE_POWER_FEATURE,
|
||||
CONF_USE_CENTRAL_BOILER_FEATURE,
|
||||
CONF_AC_MODE,
|
||||
CONF_SONOFF_TRZB_MODE,
|
||||
CONF_AUTO_REGULATION_MODE,
|
||||
CONF_AUTO_REGULATION_DTEMP,
|
||||
CONF_AUTO_REGULATION_PERIOD_MIN,
|
||||
@@ -325,6 +329,7 @@ CONF_FUNCTIONS = [
|
||||
|
||||
CONF_AUTO_REGULATION_MODES = [
|
||||
CONF_AUTO_REGULATION_NONE,
|
||||
CONF_AUTO_REGULATION_VALVE,
|
||||
CONF_AUTO_REGULATION_LIGHT,
|
||||
CONF_AUTO_REGULATION_MEDIUM,
|
||||
CONF_AUTO_REGULATION_STRONG,
|
||||
@@ -463,9 +468,9 @@ class RegulationParamVeryStrong:
|
||||
kp: float = 0.6
|
||||
ki: float = 0.1
|
||||
k_ext: float = 0.2
|
||||
offset_max: float = 4
|
||||
offset_max: float = 8
|
||||
stabilization_threshold: float = 0.1
|
||||
accumulated_error_threshold: float = 30
|
||||
accumulated_error_threshold: float = 80
|
||||
|
||||
|
||||
class EventType(Enum):
|
||||
@@ -490,6 +495,38 @@ def send_vtherm_event(hass, event_type: EventType, entity, data: dict):
|
||||
hass.bus.fire(event_type.value, data)
|
||||
|
||||
|
||||
def get_safe_float(hass, entity_id: str):
|
||||
"""Get a safe float state value for an entity.
|
||||
Return None if entity is not available"""
|
||||
if (
|
||||
entity_id is None
|
||||
or not (state := hass.states.get(entity_id))
|
||||
or state.state == "unknown"
|
||||
or state.state == "unavailable"
|
||||
):
|
||||
return None
|
||||
float_val = float(state.state)
|
||||
return None if math.isinf(float_val) or not math.isfinite(float_val) else float_val
|
||||
|
||||
|
||||
def get_tz(hass: HomeAssistant):
|
||||
"""Get the current timezone"""
|
||||
|
||||
return dt_util.get_time_zone(hass.config.time_zone)
|
||||
|
||||
|
||||
class NowClass:
|
||||
"""For testing purpose only"""
|
||||
|
||||
@staticmethod
|
||||
def get_now(hass: HomeAssistant) -> datetime:
|
||||
"""A test function to get the now.
|
||||
For testing purpose this method can be overriden to get a specific
|
||||
timestamp.
|
||||
"""
|
||||
return datetime.now(get_tz(hass))
|
||||
|
||||
|
||||
class UnknownEntity(HomeAssistantError):
|
||||
"""Error to indicate there is an unknown entity_id given."""
|
||||
|
||||
@@ -510,8 +547,8 @@ class ConfigurationNotCompleteError(HomeAssistantError):
|
||||
"""Error the configuration is not complete"""
|
||||
|
||||
|
||||
class SonoffTRVZBNbEntitiesIncorrect(HomeAssistantError):
|
||||
"""Error to indicate there is an error in the configuration of the Sonoff TRVZB.
|
||||
class ValveRegulationNbEntitiesIncorrect(HomeAssistantError):
|
||||
"""Error to indicate there is an error in the configuration of the TRV with valve regulation.
|
||||
The number of specific entities is incorrect."""
|
||||
|
||||
|
||||
|
||||
@@ -14,6 +14,6 @@
|
||||
"quality_scale": "silver",
|
||||
"requirements": [],
|
||||
"ssdp": [],
|
||||
"version": "6.8.0.alpha",
|
||||
"version": "6.8.0",
|
||||
"zeroconf": []
|
||||
}
|
||||
@@ -26,20 +26,14 @@ MIN_NB_POINT = 4 # do not calculate slope until we have enough point
|
||||
class WindowOpenDetectionAlgorithm:
|
||||
"""The class that implements the algorithm listed above"""
|
||||
|
||||
_alert_threshold: float
|
||||
_end_alert_threshold: float
|
||||
_last_slope: float
|
||||
_last_datetime: datetime
|
||||
_last_temperature: float
|
||||
_nb_point: int
|
||||
|
||||
def __init__(self, alert_threshold, end_alert_threshold) -> None:
|
||||
"""Initalize a new algorithm with the both threshold"""
|
||||
self._alert_threshold = alert_threshold
|
||||
self._end_alert_threshold = end_alert_threshold
|
||||
self._last_slope = None
|
||||
self._last_datetime = None
|
||||
self._nb_point = 0
|
||||
self._alert_threshold: float = alert_threshold
|
||||
self._end_alert_threshold: float = end_alert_threshold
|
||||
self._last_slope: float | None = None
|
||||
self._last_datetime: datetime = None
|
||||
self._last_temperature: float | None = None
|
||||
self._nb_point: int = 0
|
||||
|
||||
def check_age_last_measurement(self, temperature, datetime_now) -> float:
|
||||
""" " Check if last measurement is old and add
|
||||
|
||||
@@ -31,6 +31,7 @@ class PropAlgorithm:
|
||||
cycle_min: int,
|
||||
minimal_activation_delay: int,
|
||||
vtherm_entity_id: str = None,
|
||||
max_on_percent: float = None,
|
||||
) -> None:
|
||||
"""Initialisation of the Proportional Algorithm"""
|
||||
_LOGGER.debug(
|
||||
@@ -78,6 +79,7 @@ class PropAlgorithm:
|
||||
self._off_time_sec = self._cycle_min * 60
|
||||
self._security = False
|
||||
self._default_on_percent = 0
|
||||
self._max_on_percent = max_on_percent
|
||||
|
||||
def calculate(
|
||||
self,
|
||||
@@ -161,6 +163,15 @@ class PropAlgorithm:
|
||||
)
|
||||
self._on_percent = self._calculated_on_percent
|
||||
|
||||
if self._max_on_percent is not None and self._on_percent > self._max_on_percent:
|
||||
_LOGGER.debug(
|
||||
"%s - Heating period clamped to %s (instead of %s) due to max_on_percent setting.",
|
||||
self._vtherm_entity_id,
|
||||
self._max_on_percent,
|
||||
self._on_percent,
|
||||
)
|
||||
self._on_percent = self._max_on_percent
|
||||
|
||||
self._on_time_sec = self._on_percent * self._cycle_min * 60
|
||||
|
||||
# Do not heat for less than xx sec
|
||||
|
||||
@@ -3,7 +3,7 @@
|
||||
import logging
|
||||
import math
|
||||
|
||||
from homeassistant.core import HomeAssistant, callback, Event, CoreState
|
||||
from homeassistant.core import HomeAssistant, callback, Event, CoreState, State
|
||||
|
||||
from homeassistant.const import (
|
||||
UnitOfTime,
|
||||
@@ -23,13 +23,13 @@ from homeassistant.config_entries import ConfigEntry
|
||||
from homeassistant.helpers.entity_platform import AddEntitiesCallback
|
||||
from homeassistant.helpers.device_registry import DeviceInfo, DeviceEntryType
|
||||
from homeassistant.helpers.entity_component import EntityComponent
|
||||
from homeassistant.helpers.event import async_track_state_change_event
|
||||
from homeassistant.helpers.event import (
|
||||
async_track_state_change_event,
|
||||
)
|
||||
|
||||
from homeassistant.components.climate import (
|
||||
ClimateEntity,
|
||||
DOMAIN as CLIMATE_DOMAIN,
|
||||
HVACAction,
|
||||
HVACMode,
|
||||
)
|
||||
|
||||
|
||||
@@ -49,7 +49,8 @@ from .const import (
|
||||
CONF_THERMOSTAT_TYPE,
|
||||
CONF_THERMOSTAT_CENTRAL_CONFIG,
|
||||
CONF_USE_CENTRAL_BOILER_FEATURE,
|
||||
CONF_SONOFF_TRZB_MODE,
|
||||
CONF_AUTO_REGULATION_VALVE,
|
||||
CONF_AUTO_REGULATION_MODE,
|
||||
overrides,
|
||||
)
|
||||
|
||||
@@ -71,7 +72,9 @@ async def async_setup_entry(
|
||||
unique_id = entry.entry_id
|
||||
name = entry.data.get(CONF_NAME)
|
||||
vt_type = entry.data.get(CONF_THERMOSTAT_TYPE)
|
||||
is_sonoff_trvzb = entry.data.get(CONF_SONOFF_TRZB_MODE)
|
||||
have_valve_regulation = (
|
||||
entry.data.get(CONF_AUTO_REGULATION_MODE) == CONF_AUTO_REGULATION_VALVE
|
||||
)
|
||||
|
||||
entities = None
|
||||
|
||||
@@ -102,13 +105,13 @@ async def async_setup_entry(
|
||||
|
||||
if (
|
||||
entry.data.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_VALVE
|
||||
or is_sonoff_trvzb
|
||||
or have_valve_regulation
|
||||
):
|
||||
entities.append(ValveOpenPercentSensor(hass, unique_id, name, entry.data))
|
||||
|
||||
if (
|
||||
entry.data.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_CLIMATE
|
||||
and not is_sonoff_trvzb
|
||||
and not have_valve_regulation
|
||||
):
|
||||
entities.append(
|
||||
RegulatedTemperatureSensor(hass, unique_id, name, entry.data)
|
||||
@@ -130,7 +133,7 @@ class EnergySensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
energy = self.my_climate.total_energy
|
||||
if energy is None:
|
||||
@@ -185,7 +188,7 @@ class MeanPowerSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
if math.isnan(float(self.my_climate.mean_cycle_power)) or math.isinf(
|
||||
self.my_climate.mean_cycle_power
|
||||
@@ -242,7 +245,7 @@ class OnPercentSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
on_percent = (
|
||||
float(self.my_climate.proportional_algorithm.on_percent)
|
||||
@@ -297,7 +300,7 @@ class ValveOpenPercentSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
old_state = self._attr_native_value
|
||||
self._attr_native_value = self.my_climate.valve_open_percent
|
||||
@@ -339,7 +342,7 @@ class OnTimeSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
on_time = (
|
||||
float(self.my_climate.proportional_algorithm.on_time_sec)
|
||||
@@ -388,7 +391,7 @@ class OffTimeSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
off_time = (
|
||||
float(self.my_climate.proportional_algorithm.off_time_sec)
|
||||
@@ -436,7 +439,7 @@ class LastTemperatureSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
old_state = self._attr_native_value
|
||||
self._attr_native_value = self.my_climate.last_temperature_measure
|
||||
@@ -465,7 +468,7 @@ class LastExtTemperatureSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
old_state = self._attr_native_value
|
||||
self._attr_native_value = self.my_climate.last_ext_temperature_measure
|
||||
@@ -494,7 +497,7 @@ class TemperatureSlopeSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
last_slope = self.my_climate.last_temperature_slope
|
||||
if last_slope is None:
|
||||
@@ -547,7 +550,7 @@ class RegulatedTemperatureSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
new_temp = self.my_climate.regulated_target_temp
|
||||
if new_temp is None:
|
||||
@@ -598,7 +601,7 @@ class EMATemperatureSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
@callback
|
||||
async def async_my_climate_changed(self, event: Event = None):
|
||||
"""Called when my climate have change"""
|
||||
_LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
# _LOGGER.debug("%s - climate state change", self._attr_unique_id)
|
||||
|
||||
new_ema = self.my_climate.ema_temperature
|
||||
if new_ema is None:
|
||||
@@ -705,7 +708,7 @@ class NbActiveDeviceForBoilerSensor(SensorEntity):
|
||||
for entity in component.entities:
|
||||
if isinstance(entity, BaseThermostat) and entity.is_used_by_central_boiler:
|
||||
self._entities.append(entity)
|
||||
for under in entity.underlying_entities:
|
||||
for under in entity.activable_underlying_entities:
|
||||
underlying_entities_id.append(under.entity_id)
|
||||
if len(underlying_entities_id) > 0:
|
||||
# Arme l'écoute de la première entité
|
||||
@@ -725,25 +728,65 @@ class NbActiveDeviceForBoilerSensor(SensorEntity):
|
||||
|
||||
await self.calculate_nb_active_devices(None)
|
||||
|
||||
async def calculate_nb_active_devices(self, _):
|
||||
async def calculate_nb_active_devices(self, event: Event):
|
||||
"""Calculate the number of active VTherm that have an
|
||||
influence on central boiler"""
|
||||
|
||||
_LOGGER.debug("%s - calculating the number of active VTherm", self)
|
||||
# _LOGGER.debug("%s- calculate_nb_active_devices - the event is %s ", self, event)
|
||||
|
||||
if event is not None:
|
||||
new_state: State = event.data.get("new_state")
|
||||
# _LOGGER.debug(
|
||||
# "%s - calculate_nb_active_devices new_state is %s", self, new_state
|
||||
# )
|
||||
if not new_state:
|
||||
return
|
||||
|
||||
old_state: State = event.data.get("old_state")
|
||||
|
||||
# For underlying climate, we need to observe also the hvac_action if available
|
||||
new_hvac_action = new_state.attributes.get("hvac_action")
|
||||
old_hvac_action = (
|
||||
old_state.attributes.get("hvac_action")
|
||||
if old_state is not None
|
||||
else None
|
||||
)
|
||||
|
||||
# Filter events that are not interested for us
|
||||
if (
|
||||
old_state is not None
|
||||
and new_state.state == old_state.state
|
||||
and new_hvac_action == old_hvac_action
|
||||
):
|
||||
# A false state change
|
||||
return
|
||||
|
||||
_LOGGER.debug(
|
||||
"%s - calculating the number of active underlying device for boiler activation. change change from %s to %s",
|
||||
self,
|
||||
old_state,
|
||||
new_state,
|
||||
)
|
||||
else:
|
||||
_LOGGER.debug(
|
||||
"%s - calculating the number of active underlying device for boiler activation. First time calculation",
|
||||
self,
|
||||
)
|
||||
|
||||
nb_active = 0
|
||||
for entity in self._entities:
|
||||
nb_active += entity.nb_device_actives
|
||||
_LOGGER.debug(
|
||||
"Examining the hvac_action of %s",
|
||||
"After examining the hvac_action of %s, nb_active is %s",
|
||||
entity.name,
|
||||
nb_active,
|
||||
)
|
||||
if (
|
||||
entity.hvac_mode in [HVACMode.HEAT, HVACMode.AUTO]
|
||||
and entity.hvac_action == HVACAction.HEATING
|
||||
):
|
||||
for under in entity.underlying_entities:
|
||||
nb_active += 1 if under.is_device_active else 0
|
||||
|
||||
self._attr_native_value = nb_active
|
||||
_LOGGER.debug(
|
||||
"%s - Number of active underlying entities is %s", self, nb_active
|
||||
)
|
||||
|
||||
self.async_write_ha_state()
|
||||
|
||||
def __str__(self):
|
||||
|
||||
@@ -28,7 +28,7 @@
|
||||
"presence": "Presence detection",
|
||||
"advanced": "Advanced parameters",
|
||||
"auto_start_stop": "Auto start and stop",
|
||||
"sonoff_trvzb": "Sonoff TRVZB configuration",
|
||||
"valve_regulation": "Valve regulation configuration",
|
||||
"finalize": "All done",
|
||||
"configuration_not_complete": "Configuration not complete"
|
||||
}
|
||||
@@ -65,7 +65,7 @@
|
||||
"use_motion_feature": "Use motion detection",
|
||||
"use_power_feature": "Use power management",
|
||||
"use_presence_feature": "Use presence detection",
|
||||
"use_central_boiler_feature": "Use a central boiler. Check to add a control to your central boiler. You will have to configure the VTherm which will have a control of the central boiler after seecting this checkbox to take effect. If one VTherm requires heating, the boiler will be turned on. If no VTherm requires heating, the boiler will be turned off. Commands for turning on/off the central boiler are given in the related configuration page",
|
||||
"use_central_boiler_feature": "Use a central boiler. Check to add a control to your central boiler. You will have to configure the VTherm which will have a control of the central boiler after selecting this checkbox to take effect. If one VTherm requires heating, the boiler will be turned on. If no VTherm requires heating, the boiler will be turned off. Commands for turning on/off the central boiler are given in the related configuration page",
|
||||
"use_auto_start_stop_feature": "Use the auto start and stop feature"
|
||||
}
|
||||
},
|
||||
@@ -77,7 +77,6 @@
|
||||
"heater_keep_alive": "Switch keep-alive interval in seconds",
|
||||
"proportional_function": "Algorithm",
|
||||
"ac_mode": "AC mode",
|
||||
"sonoff_trvzb_mode": "SONOFF TRVZB mode",
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimum period",
|
||||
@@ -90,7 +89,6 @@
|
||||
"heater_keep_alive": "Optional heater switch state refresh interval. Leave empty if not required.",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"ac_mode": "Use the Air Conditioning (AC) mode",
|
||||
"sonoff_trvzb_mode": "The underlyings are SONOFF TRVZB. You have to configure some extra entities in the specific menu option 'Sonoff trvzb configuration'",
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
@@ -219,9 +217,9 @@
|
||||
"central_boiler_deactivation_service": "Command to turn-off the central boiler formatted like entity_id/service_name[/attribut:valeur]"
|
||||
}
|
||||
},
|
||||
"sonoff_trvzb": {
|
||||
"title": "Sonoff TRVZB configuration",
|
||||
"description": "Specific Sonoff TRVZB configuration",
|
||||
"valve_regulation": {
|
||||
"title": "Self-regulation with valve",
|
||||
"description": "Configuration for self-regulation with direct control of the valve",
|
||||
"data": {
|
||||
"offset_calibration_entity_ids": "Offset calibration entities",
|
||||
"opening_degree_entity_ids": "Opening degree entities",
|
||||
@@ -229,9 +227,9 @@
|
||||
"proportional_function": "Algorithm"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. There should be one per underlying climate entities",
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)"
|
||||
}
|
||||
}
|
||||
@@ -274,7 +272,7 @@
|
||||
"presence": "Presence detection",
|
||||
"advanced": "Advanced parameters",
|
||||
"auto_start_stop": "Auto start and stop",
|
||||
"sonoff_trvzb": "Sonoff TRVZB configuration",
|
||||
"valve_regulation": "Valve regulation configuration",
|
||||
"finalize": "All done",
|
||||
"configuration_not_complete": "Configuration not complete"
|
||||
}
|
||||
@@ -311,7 +309,7 @@
|
||||
"use_motion_feature": "Use motion detection",
|
||||
"use_power_feature": "Use power management",
|
||||
"use_presence_feature": "Use presence detection",
|
||||
"use_central_boiler_feature": "Use a central boiler. Check to add a control to your central boiler. You will have to configure the VTherm which will have a control of the central boiler after seecting this checkbox to take effect. If one VTherm requires heating, the boiler will be turned on. If no VTherm requires heating, the boiler will be turned off. Commands for turning on/off the central boiler are given in the related configuration page",
|
||||
"use_central_boiler_feature": "Use a central boiler. Check to add a control to your central boiler. You will have to configure the VTherm which will have a control of the central boiler after selecting this checkbox to take effect. If one VTherm requires heating, the boiler will be turned on. If no VTherm requires heating, the boiler will be turned off. Commands for turning on/off the central boiler are given in the related configuration page",
|
||||
"use_auto_start_stop_feature": "Use the auto start and stop feature"
|
||||
}
|
||||
},
|
||||
@@ -323,7 +321,6 @@
|
||||
"heater_keep_alive": "Switch keep-alive interval in seconds",
|
||||
"proportional_function": "Algorithm",
|
||||
"ac_mode": "AC mode",
|
||||
"sonoff_trvzb_mode": "SONOFF TRVZB mode",
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimum period",
|
||||
@@ -336,7 +333,6 @@
|
||||
"heater_keep_alive": "Optional heater switch state refresh interval. Leave empty if not required.",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"ac_mode": "Use the Air Conditioning (AC) mode",
|
||||
"sonoff_trvzb_mode": "The underlyings are SONOFF TRVZB. You have to configure some extra entities in the specific menu option 'Sonoff trvzb configuration'",
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
@@ -465,9 +461,9 @@
|
||||
"central_boiler_deactivation_service": "Command to turn-off the central boiler formatted like entity_id/service_name[/attribut:valeur]"
|
||||
}
|
||||
},
|
||||
"sonoff_trvzb": {
|
||||
"title": "Sonoff TRVZB configuration - {name}",
|
||||
"description": "Specific Sonoff TRVZB configuration",
|
||||
"valve_regulation": {
|
||||
"title": "Self-regulation with valve - {name}",
|
||||
"description": "Configuration for self-regulation with direct control of the valve",
|
||||
"data": {
|
||||
"offset_calibration_entity_ids": "Offset calibration entities",
|
||||
"opening_degree_entity_ids": "Opening degree entities",
|
||||
@@ -475,9 +471,9 @@
|
||||
"proportional_function": "Algorithm"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. There should be one per underlying climate entities",
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)"
|
||||
}
|
||||
}
|
||||
@@ -488,7 +484,7 @@
|
||||
"window_open_detection_method": "Only one window open detection method should be used. Use either window sensor or automatic detection through temperature threshold but not both",
|
||||
"no_central_config": "You cannot check 'use central configuration' because no central configuration was found. You need to create a Versatile Thermostat of type 'Central Configuration' to use it.",
|
||||
"service_configuration_format": "The format of the service configuration is wrong",
|
||||
"sonoff_trvzb_nb_entities_incorrect": "The number of specific entities for Sonoff TRVZB should be equal to the number of underlyings"
|
||||
"valve_regulation_nb_entities_incorrect": "The number of valve entities for valve regulation should be equal to the number of underlyings"
|
||||
},
|
||||
"abort": {
|
||||
"already_configured": "Device is already configured"
|
||||
@@ -510,7 +506,8 @@
|
||||
"auto_regulation_medium": "Medium",
|
||||
"auto_regulation_light": "Light",
|
||||
"auto_regulation_expert": "Expert",
|
||||
"auto_regulation_none": "No auto-regulation"
|
||||
"auto_regulation_none": "No auto-regulation",
|
||||
"auto_regulation_valve": "Direct control of valve"
|
||||
}
|
||||
},
|
||||
"auto_fan_mode": {
|
||||
|
||||
@@ -16,7 +16,7 @@ from homeassistant.components.climate import (
|
||||
ClimateEntityFeature,
|
||||
)
|
||||
|
||||
from .commons import NowClass, round_to_nearest
|
||||
from .commons import round_to_nearest
|
||||
from .base_thermostat import BaseThermostat, ConfigData
|
||||
from .pi_algorithm import PITemperatureRegulator
|
||||
|
||||
@@ -42,24 +42,6 @@ HVAC_ACTION_ON = [ # pylint: disable=invalid-name
|
||||
class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
"""Representation of a base class for a Versatile Thermostat over a climate"""
|
||||
|
||||
_auto_regulation_mode: str | None = None
|
||||
_regulation_algo = None
|
||||
_regulated_target_temp: float | None = None
|
||||
_auto_regulation_dtemp: float | None = None
|
||||
_auto_regulation_period_min: int | None = None
|
||||
_last_regulation_change: datetime | None = None
|
||||
# The fan mode configured in configEntry
|
||||
_auto_fan_mode: str | None = None
|
||||
# The current fan mode (could be change by service call)
|
||||
_current_auto_fan_mode: str | None = None
|
||||
# The fan_mode name depending of the current_mode
|
||||
_auto_activated_fan_mode: str | None = None
|
||||
_auto_deactivated_fan_mode: str | None = None
|
||||
_auto_start_stop_level: TYPE_AUTO_START_STOP_LEVELS = AUTO_START_STOP_LEVEL_NONE
|
||||
_auto_start_stop_algo: AutoStartStopDetectionAlgorithm | None = None
|
||||
_is_auto_start_stop_enabled: bool = False
|
||||
_follow_underlying_temp_change: bool = False
|
||||
|
||||
_entity_component_unrecorded_attributes = BaseThermostat._entity_component_unrecorded_attributes.union( # pylint: disable=protected-access
|
||||
frozenset(
|
||||
{
|
||||
@@ -87,10 +69,30 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
self, hass: HomeAssistant, unique_id: str, name: str, entry_infos: ConfigData
|
||||
):
|
||||
"""Initialize the thermostat over switch."""
|
||||
self._auto_regulation_mode: str | None = None
|
||||
self._regulation_algo = None
|
||||
self._regulated_target_temp: float | None = None
|
||||
self._auto_regulation_dtemp: float | None = None
|
||||
self._auto_regulation_period_min: int | None = None
|
||||
self._last_regulation_change: datetime | None = None
|
||||
# The fan mode configured in configEntry
|
||||
self._auto_fan_mode: str | None = None
|
||||
# The current fan mode (could be change by service call)
|
||||
self._current_auto_fan_mode: str | None = None
|
||||
# The fan_mode name depending of the current_mode
|
||||
self._auto_activated_fan_mode: str | None = None
|
||||
self._auto_deactivated_fan_mode: str | None = None
|
||||
self._auto_start_stop_level: TYPE_AUTO_START_STOP_LEVELS = (
|
||||
AUTO_START_STOP_LEVEL_NONE
|
||||
)
|
||||
self._auto_start_stop_algo: AutoStartStopDetectionAlgorithm | None = None
|
||||
self._is_auto_start_stop_enabled: bool = False
|
||||
self._follow_underlying_temp_change: bool = False
|
||||
self._last_regulation_change = None # NowClass.get_now(hass)
|
||||
|
||||
# super.__init__ calls post_init at the end. So it must be called after regulation initialization
|
||||
super().__init__(hass, unique_id, name, entry_infos)
|
||||
self._regulated_target_temp = self.target_temperature
|
||||
self._last_regulation_change = NowClass.get_now(hass)
|
||||
|
||||
@overrides
|
||||
def post_init(self, config_entry: ConfigData):
|
||||
@@ -151,15 +153,13 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
"""True if the Thermostat is over_climate"""
|
||||
return True
|
||||
|
||||
@property
|
||||
def hvac_action(self) -> HVACAction | None:
|
||||
"""Returns the current hvac_action by checking all hvac_action of the underlyings"""
|
||||
|
||||
def calculate_hvac_action(self, under_list: list) -> HVACAction | None:
|
||||
"""Calculate an hvac action based on the hvac_action of the list in argument"""
|
||||
# if one not IDLE or OFF -> return it
|
||||
# else if one IDLE -> IDLE
|
||||
# else OFF
|
||||
one_idle = False
|
||||
for under in self._underlyings:
|
||||
for under in under_list:
|
||||
if (action := under.hvac_action) not in [
|
||||
HVACAction.IDLE,
|
||||
HVACAction.OFF,
|
||||
@@ -171,13 +171,19 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
return HVACAction.IDLE
|
||||
return HVACAction.OFF
|
||||
|
||||
@property
|
||||
def hvac_action(self) -> HVACAction | None:
|
||||
"""Returns the current hvac_action by checking all hvac_action of the underlyings"""
|
||||
return self.calculate_hvac_action(self._underlyings)
|
||||
|
||||
@overrides
|
||||
async def _async_internal_set_temperature(self, temperature: float):
|
||||
"""Set the target temperature and the target temperature of underlying climate if any"""
|
||||
await super()._async_internal_set_temperature(temperature)
|
||||
|
||||
self._regulation_algo.set_target_temp(self.target_temperature)
|
||||
await self._send_regulated_temperature(force=True)
|
||||
# is done by control_heating method. No need to do it here
|
||||
# await self._send_regulated_temperature(force=True)
|
||||
|
||||
async def _send_regulated_temperature(self, force=False):
|
||||
"""Sends the regulated temperature to all underlying"""
|
||||
@@ -202,16 +208,18 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
force,
|
||||
)
|
||||
|
||||
now: datetime = NowClass.get_now(self._hass)
|
||||
period = float((now - self._last_regulation_change).total_seconds()) / 60.0
|
||||
if not force and period < self._auto_regulation_period_min:
|
||||
_LOGGER.info(
|
||||
"%s - period (%.1f) min is < %.0f min -> forget the regulation send",
|
||||
self,
|
||||
period,
|
||||
self._auto_regulation_period_min,
|
||||
if self._last_regulation_change is not None:
|
||||
period = (
|
||||
float((self.now - self._last_regulation_change).total_seconds()) / 60.0
|
||||
)
|
||||
return
|
||||
if not force and period < self._auto_regulation_period_min:
|
||||
_LOGGER.info(
|
||||
"%s - period (%.1f) min is < %.0f min -> forget the regulation send",
|
||||
self,
|
||||
period,
|
||||
self._auto_regulation_period_min,
|
||||
)
|
||||
return
|
||||
|
||||
if not self._regulated_target_temp:
|
||||
self._regulated_target_temp = self.target_temperature
|
||||
@@ -249,7 +257,7 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
new_regulated_temp,
|
||||
)
|
||||
|
||||
self._last_regulation_change = now
|
||||
self._last_regulation_change = self.now
|
||||
for under in self._underlyings:
|
||||
# issue 348 - use device temperature if configured as offset
|
||||
offset_temp = 0
|
||||
@@ -921,7 +929,10 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
|
||||
# Stop here
|
||||
return False
|
||||
elif action == AUTO_START_STOP_ACTION_ON:
|
||||
elif (
|
||||
action == AUTO_START_STOP_ACTION_ON
|
||||
and self.hvac_off_reason == HVAC_OFF_REASON_AUTO_START_STOP
|
||||
):
|
||||
_LOGGER.info(
|
||||
"%s - Turning ON the Vtherm due to auto-start-stop conditions", self
|
||||
)
|
||||
@@ -1252,6 +1263,13 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
self.choose_auto_regulation_mode(CONF_AUTO_REGULATION_SLOW)
|
||||
elif auto_regulation_mode == "Expert":
|
||||
self.choose_auto_regulation_mode(CONF_AUTO_REGULATION_EXPERT)
|
||||
else:
|
||||
_LOGGER.warning(
|
||||
"%s - auto_regulation_mode %s is not supported",
|
||||
self,
|
||||
auto_regulation_mode,
|
||||
)
|
||||
return
|
||||
|
||||
await self._send_regulated_temperature()
|
||||
self.update_custom_attributes()
|
||||
|
||||
@@ -1,13 +1,13 @@
|
||||
# pylint: disable=line-too-long, too-many-lines, abstract-method
|
||||
""" A climate over Sonoff TRVZB classe """
|
||||
""" A climate with a direct valve regulation class """
|
||||
|
||||
import logging
|
||||
from datetime import datetime
|
||||
|
||||
from homeassistant.core import HomeAssistant
|
||||
from homeassistant.components.climate import HVACMode
|
||||
from homeassistant.components.climate import HVACMode, HVACAction
|
||||
|
||||
from .underlyings import UnderlyingSonoffTRVZB
|
||||
from .underlyings import UnderlyingValveRegulation
|
||||
|
||||
# from .commons import NowClass, round_to_nearest
|
||||
from .base_thermostat import ConfigData
|
||||
@@ -21,14 +21,14 @@ from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
|
||||
class ThermostatOverSonoffTRVZB(ThermostatOverClimate):
|
||||
"""This class represent a VTherm over a Sonoff TRVZB climate"""
|
||||
class ThermostatOverClimateValve(ThermostatOverClimate):
|
||||
"""This class represent a VTherm over a climate with a direct valve regulation"""
|
||||
|
||||
_entity_component_unrecorded_attributes = ThermostatOverClimate._entity_component_unrecorded_attributes.union( # pylint: disable=protected-access
|
||||
frozenset(
|
||||
{
|
||||
"is_over_climate",
|
||||
"is_over_sonoff_trvzb",
|
||||
"have_valve_regulation",
|
||||
"underlying_entities",
|
||||
"on_time_sec",
|
||||
"off_time_sec",
|
||||
@@ -40,28 +40,25 @@ class ThermostatOverSonoffTRVZB(ThermostatOverClimate):
|
||||
}
|
||||
)
|
||||
)
|
||||
_underlyings_sonoff_trvzb: list[UnderlyingSonoffTRVZB] = []
|
||||
_valve_open_percent: int = 0
|
||||
_last_calculation_timestamp: datetime | None = None
|
||||
_auto_regulation_dpercent: float | None = None
|
||||
_auto_regulation_period_min: int | None = None
|
||||
|
||||
def __init__(
|
||||
self, hass: HomeAssistant, unique_id: str, name: str, entry_infos: ConfigData
|
||||
):
|
||||
"""Initialize the ThermostatOverSonoffTRVZB class"""
|
||||
_LOGGER.debug("%s - creating a ThermostatOverSonoffTRVZB VTherm", name)
|
||||
"""Initialize the ThermostatOverClimateValve class"""
|
||||
_LOGGER.debug("%s - creating a ThermostatOverClimateValve VTherm", name)
|
||||
self._underlyings_valve_regulation: list[UnderlyingValveRegulation] = []
|
||||
self._valve_open_percent: int | None = None
|
||||
self._last_calculation_timestamp: datetime | None = None
|
||||
self._auto_regulation_dpercent: float | None = None
|
||||
self._auto_regulation_period_min: int | None = None
|
||||
|
||||
super().__init__(hass, unique_id, name, entry_infos)
|
||||
# self._valve_open_percent: int = 0
|
||||
# self._last_calculation_timestamp: datetime | None = None
|
||||
# self._auto_regulation_dpercent: float | None = None
|
||||
# self._auto_regulation_period_min: int | None = None
|
||||
|
||||
@overrides
|
||||
def post_init(self, config_entry: ConfigData):
|
||||
"""Initialize the Thermostat and underlyings
|
||||
Beware that the underlyings list contains the climate which represent the Sonoff TRVZB
|
||||
but also the UnderlyingSonoff which reprensent the valve"""
|
||||
Beware that the underlyings list contains the climate which represent the TRV
|
||||
but also the UnderlyingValveRegulation which reprensent the valve"""
|
||||
|
||||
super().post_init(config_entry)
|
||||
|
||||
@@ -86,30 +83,36 @@ class ThermostatOverSonoffTRVZB(ThermostatOverClimate):
|
||||
self.name,
|
||||
)
|
||||
|
||||
offset_list = config_entry.get(CONF_OFFSET_CALIBRATION_LIST, [])
|
||||
opening_list = config_entry.get(CONF_OPENING_DEGREE_LIST)
|
||||
closing_list = config_entry.get(CONF_CLOSING_DEGREE_LIST, [])
|
||||
for idx, _ in enumerate(config_entry.get(CONF_UNDERLYING_LIST)):
|
||||
offset = config_entry.get(CONF_OFFSET_CALIBRATION_LIST)[idx]
|
||||
opening = config_entry.get(CONF_OPENING_DEGREE_LIST)[idx]
|
||||
closing = config_entry.get(CONF_CLOSING_DEGREE_LIST)[idx]
|
||||
under = UnderlyingSonoffTRVZB(
|
||||
offset = offset_list[idx] if idx < len(offset_list) else None
|
||||
# number of opening should equal number of underlying
|
||||
opening = opening_list[idx]
|
||||
closing = closing_list[idx] if idx < len(closing_list) else None
|
||||
under = UnderlyingValveRegulation(
|
||||
hass=self._hass,
|
||||
thermostat=self,
|
||||
offset_calibration_entity_id=offset,
|
||||
opening_degree_entity_id=opening,
|
||||
closing_degree_entity_id=closing,
|
||||
climate_underlying=self._underlyings[idx],
|
||||
)
|
||||
self._underlyings_sonoff_trvzb.append(under)
|
||||
self._underlyings_valve_regulation.append(under)
|
||||
|
||||
@overrides
|
||||
def update_custom_attributes(self):
|
||||
"""Custom attributes"""
|
||||
super().update_custom_attributes()
|
||||
|
||||
self._attr_extra_state_attributes["is_over_sonoff_trvzb"] = (
|
||||
self.is_over_sonoff_trvzb
|
||||
self._attr_extra_state_attributes["have_valve_regulation"] = (
|
||||
self.have_valve_regulation
|
||||
)
|
||||
|
||||
self._attr_extra_state_attributes["underlying_sonoff_trvzb_entities"] = [
|
||||
underlying.entity_id for underlying in self._underlyings_sonoff_trvzb
|
||||
self._attr_extra_state_attributes["underlyings_valve_regulation"] = [
|
||||
underlying.valve_entity_ids
|
||||
for underlying in self._underlyings_valve_regulation
|
||||
]
|
||||
|
||||
self._attr_extra_state_attributes["on_percent"] = (
|
||||
@@ -187,9 +190,14 @@ class ThermostatOverSonoffTRVZB(ThermostatOverClimate):
|
||||
if new_valve_percent < self._auto_regulation_dpercent:
|
||||
new_valve_percent = 0
|
||||
|
||||
dpercent = new_valve_percent - self.valve_open_percent
|
||||
dpercent = (
|
||||
new_valve_percent - self._valve_open_percent
|
||||
if self._valve_open_percent is not None
|
||||
else 0
|
||||
)
|
||||
if (
|
||||
new_valve_percent > 0
|
||||
self._last_calculation_timestamp is not None
|
||||
and new_valve_percent > 0
|
||||
and -1 * self._auto_regulation_dpercent
|
||||
<= dpercent
|
||||
< self._auto_regulation_dpercent
|
||||
@@ -202,22 +210,38 @@ class ThermostatOverSonoffTRVZB(ThermostatOverClimate):
|
||||
|
||||
return
|
||||
|
||||
if self._valve_open_percent == new_valve_percent:
|
||||
if (
|
||||
self._last_calculation_timestamp is not None
|
||||
and self._valve_open_percent == new_valve_percent
|
||||
):
|
||||
_LOGGER.debug("%s - no change in valve_open_percent.", self)
|
||||
return
|
||||
|
||||
self._valve_open_percent = new_valve_percent
|
||||
|
||||
for under in self._underlyings_sonoff_trvzb:
|
||||
under.set_valve_open_percent()
|
||||
|
||||
self._last_calculation_timestamp = now
|
||||
|
||||
self.update_custom_attributes()
|
||||
super().recalculate()
|
||||
|
||||
async def _send_regulated_temperature(self, force=False):
|
||||
"""Sends the regulated temperature to all underlying"""
|
||||
if self.target_temperature is None:
|
||||
return
|
||||
|
||||
for under in self._underlyings:
|
||||
if self.target_temperature != under.last_sent_temperature:
|
||||
await under.set_temperature(
|
||||
self.target_temperature,
|
||||
self._attr_max_temp,
|
||||
self._attr_min_temp,
|
||||
)
|
||||
|
||||
for under in self._underlyings_valve_regulation:
|
||||
await under.set_valve_open_percent()
|
||||
|
||||
@property
|
||||
def is_over_sonoff_trvzb(self) -> bool:
|
||||
"""True if the Thermostat is over_sonoff_trvzb"""
|
||||
def have_valve_regulation(self) -> bool:
|
||||
"""True if the Thermostat is regulated by valve"""
|
||||
return True
|
||||
|
||||
@property
|
||||
@@ -236,7 +260,36 @@ class ThermostatOverSonoffTRVZB(ThermostatOverClimate):
|
||||
@property
|
||||
def valve_open_percent(self) -> int:
|
||||
"""Gives the percentage of valve needed"""
|
||||
if self._hvac_mode == HVACMode.OFF:
|
||||
if self._hvac_mode == HVACMode.OFF or self._valve_open_percent is None:
|
||||
return 0
|
||||
else:
|
||||
return self._valve_open_percent
|
||||
|
||||
@property
|
||||
def hvac_action(self) -> HVACAction | None:
|
||||
"""Returns the current hvac_action by checking all hvac_action of the _underlyings_valve_regulation"""
|
||||
|
||||
return self.calculate_hvac_action(self._underlyings_valve_regulation)
|
||||
|
||||
@property
|
||||
def is_device_active(self) -> bool:
|
||||
"""A hack to overrides the state from underlyings"""
|
||||
return self.valve_open_percent > 0
|
||||
|
||||
@property
|
||||
def nb_device_actives(self) -> int:
|
||||
"""Calculate the number of active devices"""
|
||||
if self.is_device_active:
|
||||
return len(self._underlyings_valve_regulation)
|
||||
else:
|
||||
return 0
|
||||
|
||||
@property
|
||||
def activable_underlying_entities(self) -> list | None:
|
||||
"""Returns the activable underlying entities for controling the central boiler"""
|
||||
return self._underlyings_valve_regulation
|
||||
|
||||
@overrides
|
||||
async def service_set_auto_regulation_mode(self, auto_regulation_mode: str):
|
||||
"""This should not be possible in valve regulation mode"""
|
||||
return
|
||||
@@ -7,6 +7,7 @@ from homeassistant.helpers.event import (
|
||||
async_track_state_change_event,
|
||||
EventStateChangedData,
|
||||
)
|
||||
from homeassistant.core import HomeAssistant
|
||||
from homeassistant.components.climate import HVACMode
|
||||
|
||||
from .const import (
|
||||
@@ -25,28 +26,30 @@ _LOGGER = logging.getLogger(__name__)
|
||||
class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
|
||||
"""Representation of a base class for a Versatile Thermostat over a switch."""
|
||||
|
||||
_entity_component_unrecorded_attributes = BaseThermostat._entity_component_unrecorded_attributes.union( # pylint: disable=protected-access
|
||||
frozenset(
|
||||
{
|
||||
"is_over_switch",
|
||||
"is_inversed",
|
||||
"underlying_entities",
|
||||
"on_time_sec",
|
||||
"off_time_sec",
|
||||
"cycle_min",
|
||||
"function",
|
||||
"tpi_coef_int",
|
||||
"tpi_coef_ext",
|
||||
"power_percent",
|
||||
}
|
||||
_entity_component_unrecorded_attributes = (
|
||||
BaseThermostat._entity_component_unrecorded_attributes.union(
|
||||
frozenset(
|
||||
{
|
||||
"is_over_switch",
|
||||
"is_inversed",
|
||||
"underlying_entities",
|
||||
"on_time_sec",
|
||||
"off_time_sec",
|
||||
"cycle_min",
|
||||
"function",
|
||||
"tpi_coef_int",
|
||||
"tpi_coef_ext",
|
||||
"power_percent",
|
||||
"calculated_on_percent",
|
||||
}
|
||||
)
|
||||
)
|
||||
)
|
||||
|
||||
# useless for now
|
||||
# def __init__(self, hass: HomeAssistant, unique_id, name, config_entry) -> None:
|
||||
# """Initialize the thermostat over switch."""
|
||||
# super().__init__(hass, unique_id, name, config_entry)
|
||||
_is_inversed: bool | None = None
|
||||
def __init__(self, hass: HomeAssistant, unique_id, name, config_entry) -> None:
|
||||
"""Initialize the thermostat over switch."""
|
||||
self._is_inversed: bool | None = None
|
||||
super().__init__(hass, unique_id, name, config_entry)
|
||||
|
||||
@property
|
||||
def is_over_switch(self) -> bool:
|
||||
@@ -79,6 +82,7 @@ class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
|
||||
self._cycle_min,
|
||||
self._minimal_activation_delay,
|
||||
self.name,
|
||||
max_on_percent=self._max_on_percent,
|
||||
)
|
||||
|
||||
lst_switches = config_entry.get(CONF_UNDERLYING_LIST)
|
||||
@@ -144,6 +148,9 @@ class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
|
||||
self._attr_extra_state_attributes["function"] = self._proportional_function
|
||||
self._attr_extra_state_attributes["tpi_coef_int"] = self._tpi_coef_int
|
||||
self._attr_extra_state_attributes["tpi_coef_ext"] = self._tpi_coef_ext
|
||||
self._attr_extra_state_attributes[
|
||||
"calculated_on_percent"
|
||||
] = self._prop_algorithm.calculated_on_percent
|
||||
|
||||
self.async_write_ha_state()
|
||||
_LOGGER.debug(
|
||||
|
||||
@@ -43,6 +43,7 @@ class ThermostatOverValve(BaseThermostat[UnderlyingValve]): # pylint: disable=a
|
||||
"auto_regulation_dpercent",
|
||||
"auto_regulation_period_min",
|
||||
"last_calculation_timestamp",
|
||||
"calculated_on_percent",
|
||||
}
|
||||
)
|
||||
)
|
||||
@@ -96,6 +97,7 @@ class ThermostatOverValve(BaseThermostat[UnderlyingValve]): # pylint: disable=a
|
||||
self._cycle_min,
|
||||
self._minimal_activation_delay,
|
||||
self.name,
|
||||
max_on_percent=self._max_on_percent,
|
||||
)
|
||||
|
||||
lst_valves = config_entry.get(CONF_UNDERLYING_LIST)
|
||||
@@ -179,6 +181,9 @@ class ThermostatOverValve(BaseThermostat[UnderlyingValve]): # pylint: disable=a
|
||||
if self._last_calculation_timestamp
|
||||
else None
|
||||
)
|
||||
self._attr_extra_state_attributes[
|
||||
"calculated_on_percent"
|
||||
] = self._prop_algorithm.calculated_on_percent
|
||||
|
||||
self.async_write_ha_state()
|
||||
_LOGGER.debug(
|
||||
@@ -243,8 +248,9 @@ class ThermostatOverValve(BaseThermostat[UnderlyingValve]): # pylint: disable=a
|
||||
|
||||
self._valve_open_percent = new_valve_percent
|
||||
|
||||
for under in self._underlyings:
|
||||
under.set_valve_open_percent()
|
||||
# is one in start_cycle now
|
||||
# for under in self._underlyings:
|
||||
# under.set_valve_open_percent()
|
||||
|
||||
self._last_calculation_timestamp = now
|
||||
|
||||
|
||||
@@ -28,7 +28,7 @@
|
||||
"presence": "Presence detection",
|
||||
"advanced": "Advanced parameters",
|
||||
"auto_start_stop": "Auto start and stop",
|
||||
"sonoff_trvzb": "Sonoff TRVZB configuration",
|
||||
"valve_regulation": "Valve regulation configuration",
|
||||
"finalize": "All done",
|
||||
"configuration_not_complete": "Configuration not complete"
|
||||
}
|
||||
@@ -65,7 +65,7 @@
|
||||
"use_motion_feature": "Use motion detection",
|
||||
"use_power_feature": "Use power management",
|
||||
"use_presence_feature": "Use presence detection",
|
||||
"use_central_boiler_feature": "Use a central boiler. Check to add a control to your central boiler. You will have to configure the VTherm which will have a control of the central boiler after seecting this checkbox to take effect. If one VTherm requires heating, the boiler will be turned on. If no VTherm requires heating, the boiler will be turned off. Commands for turning on/off the central boiler are given in the related configuration page",
|
||||
"use_central_boiler_feature": "Use a central boiler. Check to add a control to your central boiler. You will have to configure the VTherm which will have a control of the central boiler after selecting this checkbox to take effect. If one VTherm requires heating, the boiler will be turned on. If no VTherm requires heating, the boiler will be turned off. Commands for turning on/off the central boiler are given in the related configuration page",
|
||||
"use_auto_start_stop_feature": "Use the auto start and stop feature"
|
||||
}
|
||||
},
|
||||
@@ -77,7 +77,6 @@
|
||||
"heater_keep_alive": "Switch keep-alive interval in seconds",
|
||||
"proportional_function": "Algorithm",
|
||||
"ac_mode": "AC mode",
|
||||
"sonoff_trvzb_mode": "SONOFF TRVZB mode",
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimum period",
|
||||
@@ -90,7 +89,6 @@
|
||||
"heater_keep_alive": "Optional heater switch state refresh interval. Leave empty if not required.",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"ac_mode": "Use the Air Conditioning (AC) mode",
|
||||
"sonoff_trvzb_mode": "The underlyings are SONOFF TRVZB. You have to configure some extra entities in the specific menu option 'Sonoff trvzb configuration'",
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
@@ -219,9 +217,9 @@
|
||||
"central_boiler_deactivation_service": "Command to turn-off the central boiler formatted like entity_id/service_name[/attribut:valeur]"
|
||||
}
|
||||
},
|
||||
"sonoff_trvzb": {
|
||||
"title": "Sonoff TRVZB configuration",
|
||||
"description": "Specific Sonoff TRVZB configuration",
|
||||
"valve_regulation": {
|
||||
"title": "Self-regulation with valve",
|
||||
"description": "Configuration for self-regulation with direct control of the valve",
|
||||
"data": {
|
||||
"offset_calibration_entity_ids": "Offset calibration entities",
|
||||
"opening_degree_entity_ids": "Opening degree entities",
|
||||
@@ -229,9 +227,9 @@
|
||||
"proportional_function": "Algorithm"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. There should be one per underlying climate entities",
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)"
|
||||
}
|
||||
}
|
||||
@@ -274,7 +272,7 @@
|
||||
"presence": "Presence detection",
|
||||
"advanced": "Advanced parameters",
|
||||
"auto_start_stop": "Auto start and stop",
|
||||
"sonoff_trvzb": "Sonoff TRVZB configuration",
|
||||
"valve_regulation": "Valve regulation configuration",
|
||||
"finalize": "All done",
|
||||
"configuration_not_complete": "Configuration not complete"
|
||||
}
|
||||
@@ -311,7 +309,7 @@
|
||||
"use_motion_feature": "Use motion detection",
|
||||
"use_power_feature": "Use power management",
|
||||
"use_presence_feature": "Use presence detection",
|
||||
"use_central_boiler_feature": "Use a central boiler. Check to add a control to your central boiler. You will have to configure the VTherm which will have a control of the central boiler after seecting this checkbox to take effect. If one VTherm requires heating, the boiler will be turned on. If no VTherm requires heating, the boiler will be turned off. Commands for turning on/off the central boiler are given in the related configuration page",
|
||||
"use_central_boiler_feature": "Use a central boiler. Check to add a control to your central boiler. You will have to configure the VTherm which will have a control of the central boiler after selecting this checkbox to take effect. If one VTherm requires heating, the boiler will be turned on. If no VTherm requires heating, the boiler will be turned off. Commands for turning on/off the central boiler are given in the related configuration page",
|
||||
"use_auto_start_stop_feature": "Use the auto start and stop feature"
|
||||
}
|
||||
},
|
||||
@@ -323,7 +321,6 @@
|
||||
"heater_keep_alive": "Switch keep-alive interval in seconds",
|
||||
"proportional_function": "Algorithm",
|
||||
"ac_mode": "AC mode",
|
||||
"sonoff_trvzb_mode": "SONOFF TRVZB mode",
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimum period",
|
||||
@@ -336,7 +333,6 @@
|
||||
"heater_keep_alive": "Optional heater switch state refresh interval. Leave empty if not required.",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"ac_mode": "Use the Air Conditioning (AC) mode",
|
||||
"sonoff_trvzb_mode": "The underlyings are SONOFF TRVZB. You have to configure some extra entities in the specific menu option 'Sonoff trvzb configuration'",
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
@@ -454,7 +450,7 @@
|
||||
}
|
||||
},
|
||||
"central_boiler": {
|
||||
"title": "Control of the central boiler",
|
||||
"title": "Control of the central boiler - {name}",
|
||||
"description": "Enter the services to call to turn on/off the central boiler. Leave blank if no service call is to be made (in this case, you will have to manage the turning on/off of your central boiler yourself). The service called must be formatted as follows: `entity_id/service_name[/attribute:value]` (/attribute:value is optional)\nFor example:\n- to turn on a switch: `switch.controle_chaudiere/switch.turn_on`\n- to turn off a switch: `switch.controle_chaudiere/switch.turn_off`\n- to program the boiler to 25° and thus force its ignition: `climate.thermostat_chaudiere/climate.set_temperature/temperature:25`\n- to send 10° to the boiler and thus force its extinction: `climate.thermostat_chaudiere/climate.set_temperature/temperature:10`",
|
||||
"data": {
|
||||
"central_boiler_activation_service": "Command to turn-on",
|
||||
@@ -465,9 +461,9 @@
|
||||
"central_boiler_deactivation_service": "Command to turn-off the central boiler formatted like entity_id/service_name[/attribut:valeur]"
|
||||
}
|
||||
},
|
||||
"sonoff_trvzb": {
|
||||
"title": "Sonoff TRVZB configuration",
|
||||
"description": "Specific Sonoff TRVZB configuration",
|
||||
"valve_regulation": {
|
||||
"title": "Self-regulation with valve - {name}",
|
||||
"description": "Configuration for self-regulation with direct control of the valve",
|
||||
"data": {
|
||||
"offset_calibration_entity_ids": "Offset calibration entities",
|
||||
"opening_degree_entity_ids": "Opening degree entities",
|
||||
@@ -475,9 +471,9 @@
|
||||
"proportional_function": "Algorithm"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. There should be one per underlying climate entities",
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)"
|
||||
}
|
||||
}
|
||||
@@ -488,7 +484,7 @@
|
||||
"window_open_detection_method": "Only one window open detection method should be used. Use either window sensor or automatic detection through temperature threshold but not both",
|
||||
"no_central_config": "You cannot check 'use central configuration' because no central configuration was found. You need to create a Versatile Thermostat of type 'Central Configuration' to use it.",
|
||||
"service_configuration_format": "The format of the service configuration is wrong",
|
||||
"sonoff_trvzb_nb_entities_incorrect": "The number of specific entities for Sonoff TRVZB should be equal to the number of underlyings"
|
||||
"valve_regulation_nb_entities_incorrect": "The number of valve entities for valve regulation should be equal to the number of underlyings"
|
||||
},
|
||||
"abort": {
|
||||
"already_configured": "Device is already configured"
|
||||
@@ -510,7 +506,8 @@
|
||||
"auto_regulation_medium": "Medium",
|
||||
"auto_regulation_light": "Light",
|
||||
"auto_regulation_expert": "Expert",
|
||||
"auto_regulation_none": "No auto-regulation"
|
||||
"auto_regulation_none": "No auto-regulation",
|
||||
"auto_regulation_valve": "Direct control of valve"
|
||||
}
|
||||
},
|
||||
"auto_fan_mode": {
|
||||
|
||||
@@ -28,7 +28,7 @@
|
||||
"presence": "Détection de présence",
|
||||
"advanced": "Paramètres avancés",
|
||||
"auto_start_stop": "Allumage/extinction automatique",
|
||||
"sonoff_trvzb": "Configuration spécifique à Sonoff TRVZB",
|
||||
"valve_regulation": "Configuration de la regulation par vanne",
|
||||
"finalize": "Finaliser la création",
|
||||
"configuration_not_complete": "Configuration incomplète"
|
||||
}
|
||||
@@ -77,7 +77,6 @@
|
||||
"heater_keep_alive": "keep-alive (sec)",
|
||||
"proportional_function": "Algorithme",
|
||||
"ac_mode": "AC mode ?",
|
||||
"sonoff_trvzb_mode": "Mode Sonoff TRVZB",
|
||||
"auto_regulation_mode": "Auto-régulation",
|
||||
"auto_regulation_dtemp": "Seuil de régulation",
|
||||
"auto_regulation_periode_min": "Période minimale de régulation",
|
||||
@@ -90,9 +89,8 @@
|
||||
"heater_keep_alive": "Intervalle de rafraichissement du switch en secondes. Laisser vide pour désactiver. À n'utiliser que pour les switchs qui le nécessite.",
|
||||
"proportional_function": "Algorithme à utiliser (Seul TPI est disponible pour l'instant)",
|
||||
"ac_mode": "Utilisation du mode Air Conditionné (AC)",
|
||||
"sonoff_trvzb_mode": "Les équipements sont des Sonoff TRVZB. Vous devez configurer les entités dédiées dans le menu 'Configuration Sonoff TRVZB'",
|
||||
"auto_regulation_mode": "Ajustement automatique de la température cible",
|
||||
"auto_regulation_dtemp": "Le seuil en ° (ou % pour les valves) en-dessous duquel la régulation ne sera pas envoyée",
|
||||
"auto_regulation_mode": "Utilisation de l'auto-régulation faite par VTherm",
|
||||
"auto_regulation_dtemp": "Le seuil en ° (ou % pour les vannes) en-dessous duquel la régulation ne sera pas envoyée",
|
||||
"auto_regulation_periode_min": "La durée en minutes entre deux mise à jour faites par la régulation",
|
||||
"auto_regulation_use_device_temp": "Compenser la temperature interne du sous-jacent pour accélérer l'auto-régulation",
|
||||
"inverse_switch_command": "Inverse la commande du switch pour une installation avec fil pilote et diode",
|
||||
@@ -219,19 +217,19 @@
|
||||
"central_boiler_deactivation_service": "Commande à éxecuter pour étiendre la chaudière centrale au format entity_id/service_name[/attribut:valeur]"
|
||||
}
|
||||
},
|
||||
"sonoff_trvzb": {
|
||||
"title": "Configuration Sonoff TRVZB",
|
||||
"description": "Configuration spécifique des Sonoff TRVZB",
|
||||
"valve_regulation": {
|
||||
"title": "Auto-régulation par vanne - {name}",
|
||||
"description": "Configuration de l'auto-régulation par controle direct de la vanne",
|
||||
"data": {
|
||||
"offset_calibration_entity_ids": "Entités de 'Offset calibration'",
|
||||
"opening_degree_entity_ids": "Entités de 'Opening degree'",
|
||||
"closing_degree_entity_ids": "Entités de 'Closing degree'",
|
||||
"offset_calibration_entity_ids": "Entités de 'calibrage du décalage''",
|
||||
"opening_degree_entity_ids": "Entités 'ouverture de vanne'",
|
||||
"closing_degree_entity_ids": "Entités 'fermeture de la vanne'",
|
||||
"proportional_function": "Algorithme"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "La liste des entités 'offset calibration' entities. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"opening_degree_entity_ids": "La liste des entités 'opening degree' entities. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"closing_degree_entity_ids": "La liste des entités 'closing degree' entities. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"offset_calibration_entity_ids": "La liste des entités 'calibrage du décalage' (offset calibration). Configurez le si votre TRV possède cette fonction pour une meilleure régulation. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"opening_degree_entity_ids": "La liste des entités 'ouverture de vanne'. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"closing_degree_entity_ids": "La liste des entités 'fermeture de la vanne'. Configurez le si votre TRV possède cette fonction pour une meilleure régulation. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"proportional_function": "Algorithme à utiliser (seulement TPI est disponible)"
|
||||
}
|
||||
}
|
||||
@@ -274,7 +272,7 @@
|
||||
"presence": "Détection de présence",
|
||||
"advanced": "Paramètres avancés",
|
||||
"auto_start_stop": "Allumage/extinction automatique",
|
||||
"sonoff_trvzb": "Configuration spécifique à Sonoff TRVZB",
|
||||
"valve_regulation": "Configuration de la regulation par vanne",
|
||||
"finalize": "Finaliser les modifications",
|
||||
"configuration_not_complete": "Configuration incomplète"
|
||||
}
|
||||
@@ -323,7 +321,6 @@
|
||||
"heater_keep_alive": "keep-alive (sec)",
|
||||
"proportional_function": "Algorithme",
|
||||
"ac_mode": "AC mode ?",
|
||||
"sonoff_trvzb_mode": "Mode Sonoff TRVZB",
|
||||
"auto_regulation_mode": "Auto-régulation",
|
||||
"auto_regulation_dtemp": "Seuil de régulation",
|
||||
"auto_regulation_periode_min": "Période minimale de régulation",
|
||||
@@ -336,9 +333,8 @@
|
||||
"heater_keep_alive": "Intervalle de rafraichissement du switch en secondes. Laisser vide pour désactiver. À n'utiliser que pour les switchs qui le nécessite.",
|
||||
"proportional_function": "Algorithme à utiliser (Seul TPI est disponible pour l'instant)",
|
||||
"ac_mode": "Utilisation du mode Air Conditionné (AC)",
|
||||
"sonoff_trvzb_mode": "Les équipements sont des Sonoff TRVZB. Vous devez configurer les entités dédiées dans le menu 'Configuration Sonoff TRVZB'",
|
||||
"auto_regulation_mode": "Ajustement automatique de la température cible",
|
||||
"auto_regulation_dtemp": "Le seuil en ° (ou % pour les valves) en-dessous duquel la régulation ne sera pas envoyée",
|
||||
"auto_regulation_mode": "Utilisation de l'auto-régulation faite par VTherm",
|
||||
"auto_regulation_dtemp": "Le seuil en ° (ou % pour les vannes) en-dessous duquel la régulation ne sera pas envoyée",
|
||||
"auto_regulation_periode_min": "La durée en minutes entre deux mise à jour faites par la régulation",
|
||||
"auto_regulation_use_device_temp": "Compenser la temperature interne du sous-jacent pour accélérer l'auto-régulation",
|
||||
"inverse_switch_command": "Inverse la commande du switch pour une installation avec fil pilote et diode",
|
||||
@@ -459,19 +455,19 @@
|
||||
"central_boiler_deactivation_service": "Commande à éxecuter pour étiendre la chaudière centrale au format entity_id/service_name[/attribut:valeur]"
|
||||
}
|
||||
},
|
||||
"sonoff_trvzb": {
|
||||
"title": "Configuration Sonoff TRVZB - {name}",
|
||||
"description": "Configuration spécifique des Sonoff TRVZB",
|
||||
"valve_regulation": {
|
||||
"title": "Auto-régulation par vanne - {name}",
|
||||
"description": "Configuration de l'auto-régulation par controle direct de la vanne",
|
||||
"data": {
|
||||
"offset_calibration_entity_ids": "Entités de 'Offset calibration'",
|
||||
"opening_degree_entity_ids": "Entités de 'Opening degree'",
|
||||
"closing_degree_entity_ids": "Entités de 'Closing degree'",
|
||||
"offset_calibration_entity_ids": "Entités de 'calibrage du décalage''",
|
||||
"opening_degree_entity_ids": "Entités 'ouverture de vanne'",
|
||||
"closing_degree_entity_ids": "Entités 'fermeture de la vanne'",
|
||||
"proportional_function": "Algorithme"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "La liste des entités 'offset calibration' entities. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"opening_degree_entity_ids": "La liste des entités 'opening degree' entities. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"closing_degree_entity_ids": "La liste des entités 'closing degree' entities. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"offset_calibration_entity_ids": "La liste des entités 'calibrage du décalage' (offset calibration). Configurez le si votre TRV possède cette fonction pour une meilleure régulation. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"opening_degree_entity_ids": "La liste des entités 'ouverture de vanne'. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"closing_degree_entity_ids": "La liste des entités 'fermeture de la vanne'. Configurez le si votre TRV possède cette fonction pour une meilleure régulation. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"proportional_function": "Algorithme à utiliser (seulement TPI est disponible)"
|
||||
}
|
||||
}
|
||||
@@ -482,7 +478,7 @@
|
||||
"window_open_detection_method": "Une seule méthode de détection des ouvertures ouvertes doit être utilisée. Utilisez le détecteur d'ouverture ou les seuils de température mais pas les deux.",
|
||||
"no_central_config": "Vous ne pouvez pas cocher 'Utiliser la configuration centrale' car aucune configuration centrale n'a été trouvée. Vous devez créer un Versatile Thermostat de type 'Central Configuration' pour pouvoir l'utiliser.",
|
||||
"service_configuration_format": "Mauvais format de la configuration du service",
|
||||
"sonoff_trvzb_nb_entities_incorrect": "Le nombre d'entités spécifiques au Sonoff TRVZB doit être égal au nombre d'entité sous-jacentes"
|
||||
"valve_regulation_nb_entities_incorrect": "Le nombre d'entités pour la régulation par vanne doit être égal au nombre d'entité sous-jacentes"
|
||||
},
|
||||
"abort": {
|
||||
"already_configured": "Le device est déjà configuré"
|
||||
@@ -504,7 +500,8 @@
|
||||
"auto_regulation_medium": "Moyenne",
|
||||
"auto_regulation_light": "Légère",
|
||||
"auto_regulation_expert": "Expert",
|
||||
"auto_regulation_none": "Aucune"
|
||||
"auto_regulation_none": "Aucune",
|
||||
"auto_regulation_valve": "Contrôle direct de la vanne"
|
||||
}
|
||||
},
|
||||
"auto_fan_mode": {
|
||||
|
||||
@@ -32,7 +32,7 @@ from homeassistant.helpers.entity_component import EntityComponent
|
||||
from homeassistant.helpers.event import async_call_later
|
||||
from homeassistant.util.unit_conversion import TemperatureConverter
|
||||
|
||||
from .const import UnknownEntity, overrides
|
||||
from .const import UnknownEntity, overrides, get_safe_float
|
||||
from .keep_alive import IntervalCaller
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
@@ -53,8 +53,8 @@ class UnderlyingEntityType(StrEnum):
|
||||
# a valve
|
||||
VALVE = "valve"
|
||||
|
||||
# a Sonoff TRVZB
|
||||
SONOFF_TRVZB = "sonoff_trvzb"
|
||||
# a direct valve regulation
|
||||
VALVE_REGULATION = "valve_regulation"
|
||||
|
||||
|
||||
class UnderlyingEntity:
|
||||
@@ -871,7 +871,11 @@ class UnderlyingValve(UnderlyingEntity):
|
||||
_last_sent_temperature = None
|
||||
|
||||
def __init__(
|
||||
self, hass: HomeAssistant, thermostat: Any, valve_entity_id: str
|
||||
self,
|
||||
hass: HomeAssistant,
|
||||
thermostat: Any,
|
||||
valve_entity_id: str,
|
||||
entity_type: UnderlyingEntityType = UnderlyingEntityType.VALVE,
|
||||
) -> None:
|
||||
"""Initialize the underlying valve"""
|
||||
|
||||
@@ -884,7 +888,7 @@ class UnderlyingValve(UnderlyingEntity):
|
||||
self._async_cancel_cycle = None
|
||||
self._should_relaunch_control_heating = False
|
||||
self._hvac_mode = None
|
||||
self._percent_open = self._thermostat.valve_open_percent
|
||||
self._percent_open = None # self._thermostat.valve_open_percent
|
||||
self._valve_entity_id = valve_entity_id
|
||||
|
||||
async def _send_value_to_number(self, number_entity_id: str, value: int):
|
||||
@@ -920,7 +924,7 @@ class UnderlyingValve(UnderlyingEntity):
|
||||
|
||||
async def turn_on(self):
|
||||
"""Nothing to do for Valve because it cannot be turned on"""
|
||||
self.set_valve_open_percent()
|
||||
await self.set_valve_open_percent()
|
||||
|
||||
async def set_hvac_mode(self, hvac_mode: HVACMode) -> bool:
|
||||
"""Set the HVACmode. Returns true if something have change"""
|
||||
@@ -958,11 +962,8 @@ class UnderlyingValve(UnderlyingEntity):
|
||||
force=False,
|
||||
):
|
||||
"""We use this function to change the on_percent"""
|
||||
if force:
|
||||
# self._percent_open = self.cap_sent_value(self._percent_open)
|
||||
# await self.send_percent_open()
|
||||
# avoid to send 2 times the same value at startup
|
||||
self.set_valve_open_percent()
|
||||
# if force:
|
||||
await self.set_valve_open_percent()
|
||||
|
||||
@overrides
|
||||
def cap_sent_value(self, value) -> float:
|
||||
@@ -995,7 +996,7 @@ class UnderlyingValve(UnderlyingEntity):
|
||||
|
||||
return new_value
|
||||
|
||||
def set_valve_open_percent(self):
|
||||
async def set_valve_open_percent(self):
|
||||
"""Update the valve open percent"""
|
||||
caped_val = self.cap_sent_value(self._thermostat.valve_open_percent)
|
||||
if self._percent_open == caped_val:
|
||||
@@ -1009,19 +1010,16 @@ class UnderlyingValve(UnderlyingEntity):
|
||||
"%s - Setting valve ouverture percent to %s", self, self._percent_open
|
||||
)
|
||||
# Send the change to the valve, in background
|
||||
self._hass.create_task(self.send_percent_open())
|
||||
# self._hass.create_task(self.send_percent_open())
|
||||
await self.send_percent_open()
|
||||
|
||||
def remove_entity(self):
|
||||
"""Remove the entity after stopping its cycle"""
|
||||
self._cancel_cycle()
|
||||
|
||||
|
||||
class UnderlyingSonoffTRVZB(UnderlyingValve):
|
||||
"""A specific underlying class for Sonoff TRVZB TRV"""
|
||||
|
||||
_offset_calibration_entity_id: str
|
||||
_opening_degree_entity_id: str
|
||||
_closing_degree_entity_id: str
|
||||
class UnderlyingValveRegulation(UnderlyingValve):
|
||||
"""A specific underlying class for Valve regulation"""
|
||||
|
||||
def __init__(
|
||||
self,
|
||||
@@ -1030,15 +1028,23 @@ class UnderlyingSonoffTRVZB(UnderlyingValve):
|
||||
offset_calibration_entity_id: str,
|
||||
opening_degree_entity_id: str,
|
||||
closing_degree_entity_id: str,
|
||||
climate_underlying: UnderlyingClimate,
|
||||
) -> None:
|
||||
"""Initialize the underlying Sonoff TRV"""
|
||||
super().__init__(hass, thermostat, opening_degree_entity_id)
|
||||
self._offset_calibration_entity_id = offset_calibration_entity_id
|
||||
self._opening_degree_entity_id = opening_degree_entity_id
|
||||
self._closing_degree_entity_id = closing_degree_entity_id
|
||||
self._is_min_max_initialized = False
|
||||
self._max_opening_degree = None
|
||||
self._min_offset_calibration = None
|
||||
"""Initialize the underlying TRV with valve regulation"""
|
||||
super().__init__(
|
||||
hass,
|
||||
thermostat,
|
||||
opening_degree_entity_id,
|
||||
entity_type=UnderlyingEntityType.VALVE_REGULATION,
|
||||
)
|
||||
self._offset_calibration_entity_id: str = offset_calibration_entity_id
|
||||
self._opening_degree_entity_id: str = opening_degree_entity_id
|
||||
self._closing_degree_entity_id: str = closing_degree_entity_id
|
||||
self._climate_underlying = climate_underlying
|
||||
self._is_min_max_initialized: bool = False
|
||||
self._max_opening_degree: float = None
|
||||
self._min_offset_calibration: float = None
|
||||
self._max_offset_calibration: float = None
|
||||
|
||||
async def send_percent_open(self):
|
||||
"""Send the percent open to the underlying valve"""
|
||||
@@ -1049,13 +1055,21 @@ class UnderlyingSonoffTRVZB(UnderlyingValve):
|
||||
self._max_opening_degree = self._hass.states.get(
|
||||
self._opening_degree_entity_id
|
||||
).attributes.get("max")
|
||||
self._min_offset_calibration = self._hass.states.get(
|
||||
self._offset_calibration_entity_id
|
||||
).attributes.get("min")
|
||||
|
||||
self._is_min_max_initialized = (
|
||||
self._max_opening_degree is not None
|
||||
and self._min_offset_calibration is not None
|
||||
if self.have_offset_calibration_entity:
|
||||
self._min_offset_calibration = self._hass.states.get(
|
||||
self._offset_calibration_entity_id
|
||||
).attributes.get("min")
|
||||
self._max_offset_calibration = self._hass.states.get(
|
||||
self._offset_calibration_entity_id
|
||||
).attributes.get("max")
|
||||
|
||||
self._is_min_max_initialized = self._max_opening_degree is not None and (
|
||||
not self.have_offset_calibration_entity
|
||||
or (
|
||||
self._min_offset_calibration is not None
|
||||
and self._max_offset_calibration is not None
|
||||
)
|
||||
)
|
||||
|
||||
if not self._is_min_max_initialized:
|
||||
@@ -1067,15 +1081,46 @@ class UnderlyingSonoffTRVZB(UnderlyingValve):
|
||||
# Send opening_degree
|
||||
await super().send_percent_open()
|
||||
|
||||
# Send closing_degree. TODO 100 hard-coded or take the max of the _closing_degree_entity_id ?
|
||||
await self._send_value_to_number(
|
||||
self._closing_degree_entity_id,
|
||||
self._max_opening_degree - self._percent_open,
|
||||
)
|
||||
# Send closing_degree if set
|
||||
closing_degree = None
|
||||
if self.have_closing_degree_entity:
|
||||
await self._send_value_to_number(
|
||||
self._closing_degree_entity_id,
|
||||
closing_degree := self._max_opening_degree - self._percent_open,
|
||||
)
|
||||
|
||||
# send offset_calibration to the min value
|
||||
await self._send_value_to_number(
|
||||
self._offset_calibration_entity_id, self._min_offset_calibration
|
||||
# send offset_calibration to the difference between target temp and local temp
|
||||
offset = None
|
||||
if self.have_offset_calibration_entity:
|
||||
if (
|
||||
(local_temp := self._climate_underlying.underlying_current_temperature)
|
||||
is not None
|
||||
and (room_temp := self._thermostat.current_temperature) is not None
|
||||
and (
|
||||
current_offset := get_safe_float(
|
||||
self._hass, self._offset_calibration_entity_id
|
||||
)
|
||||
)
|
||||
is not None
|
||||
):
|
||||
offset = min(
|
||||
self._max_offset_calibration,
|
||||
max(
|
||||
self._min_offset_calibration,
|
||||
room_temp - (local_temp - current_offset),
|
||||
),
|
||||
)
|
||||
|
||||
await self._send_value_to_number(
|
||||
self._offset_calibration_entity_id, offset
|
||||
)
|
||||
|
||||
_LOGGER.debug(
|
||||
"%s - valve regulation - I have sent offset_calibration=%s opening_degree=%s closing_degree=%s",
|
||||
self,
|
||||
offset,
|
||||
self._percent_open,
|
||||
closing_degree,
|
||||
)
|
||||
|
||||
@property
|
||||
@@ -1093,9 +1138,53 @@ class UnderlyingSonoffTRVZB(UnderlyingValve):
|
||||
"""The offset_calibration_entity_id"""
|
||||
return self._closing_degree_entity_id
|
||||
|
||||
@property
|
||||
def have_closing_degree_entity(self) -> bool:
|
||||
"""Return True if the underlying have a closing_degree entity"""
|
||||
return self._closing_degree_entity_id is not None
|
||||
|
||||
@property
|
||||
def have_offset_calibration_entity(self) -> bool:
|
||||
"""Return True if the underlying have a offset_calibration entity"""
|
||||
return self._offset_calibration_entity_id is not None
|
||||
|
||||
@property
|
||||
def hvac_modes(self) -> list[HVACMode]:
|
||||
"""Get the hvac_modes"""
|
||||
if not self.is_initialized:
|
||||
return []
|
||||
return [HVACMode.OFF, HVACMode.HEAT]
|
||||
|
||||
@overrides
|
||||
async def start_cycle(
|
||||
self,
|
||||
hvac_mode: HVACMode,
|
||||
_1,
|
||||
_2,
|
||||
_3,
|
||||
force=False,
|
||||
):
|
||||
"""We use this function to change the on_percent"""
|
||||
# if force:
|
||||
await self.set_valve_open_percent()
|
||||
|
||||
@property
|
||||
def is_device_active(self):
|
||||
"""If the opening valve is open."""
|
||||
try:
|
||||
return get_safe_float(self._hass, self._opening_degree_entity_id) > 0
|
||||
except Exception: # pylint: disable=broad-exception-caught
|
||||
return False
|
||||
|
||||
@property
|
||||
def valve_entity_ids(self) -> [str]:
|
||||
"""get an arrary with all entityd id of the valve"""
|
||||
ret = []
|
||||
for entity in [
|
||||
self.opening_degree_entity_id,
|
||||
self.closing_degree_entity_id,
|
||||
self.offset_calibration_entity_id,
|
||||
]:
|
||||
if entity:
|
||||
ret.append(entity)
|
||||
return ret
|
||||
|
||||
@@ -15,6 +15,7 @@ from .const import (
|
||||
CONF_SAFETY_MODE,
|
||||
CONF_THERMOSTAT_TYPE,
|
||||
CONF_THERMOSTAT_CENTRAL_CONFIG,
|
||||
CONF_MAX_ON_PERCENT,
|
||||
)
|
||||
|
||||
VTHERM_API_NAME = "vtherm_api"
|
||||
@@ -60,6 +61,7 @@ class VersatileThermostatAPI(dict):
|
||||
self._central_mode_select = None
|
||||
# A dict that will store all Number entities which holds the temperature
|
||||
self._number_temperatures = dict()
|
||||
self._max_on_percent = None
|
||||
|
||||
def find_central_configuration(self):
|
||||
"""Search for a central configuration"""
|
||||
@@ -107,6 +109,12 @@ class VersatileThermostatAPI(dict):
|
||||
if self._safety_mode:
|
||||
_LOGGER.debug("We have found safet_mode params %s", self._safety_mode)
|
||||
|
||||
self._max_on_percent = config.get(CONF_MAX_ON_PERCENT)
|
||||
if self._max_on_percent:
|
||||
_LOGGER.debug(
|
||||
"We have found max_on_percent setting %s", self._max_on_percent
|
||||
)
|
||||
|
||||
def register_central_boiler(self, central_boiler_entity):
|
||||
"""Register the central boiler entity. This is used by the CentralBoilerBinarySensor
|
||||
class to register itself at creation"""
|
||||
@@ -171,7 +179,8 @@ class VersatileThermostatAPI(dict):
|
||||
# ):
|
||||
# await entity.init_presets(self.find_central_configuration())
|
||||
|
||||
# A little hack to test if the climate is a VTherm. Cannot use isinstance due to circular dependency of BaseThermostat
|
||||
# A little hack to test if the climate is a VTherm. Cannot use isinstance
|
||||
# due to circular dependency of BaseThermostat
|
||||
if (
|
||||
entity.device_info
|
||||
and entity.device_info.get("model", None) == DOMAIN
|
||||
@@ -241,6 +250,11 @@ class VersatileThermostatAPI(dict):
|
||||
"""Get the safety_mode params"""
|
||||
return self._safety_mode
|
||||
|
||||
@property
|
||||
def max_on_percent(self):
|
||||
"""Get the max_open_percent params"""
|
||||
return self._max_on_percent
|
||||
|
||||
@property
|
||||
def central_boiler_entity(self):
|
||||
"""Get the central boiler binary_sensor entity"""
|
||||
|
||||
247
documentation/fr/additions.md
Normal file
@@ -0,0 +1,247 @@
|
||||
# Quelques compléments indispensables
|
||||
|
||||
- [Quelques compléments indispensables](#quelques-compléments-indispensables)
|
||||
- [Bien mieux avec le Versatile Thermostat UI Card](#bien-mieux-avec-le-versatile-thermostat-ui-card)
|
||||
- [Encore mieux avec le composant Scheduler !](#encore-mieux-avec-le-composant-scheduler-)
|
||||
- [Encore bien mieux avec la custom:simple-thermostat front integration](#encore-bien-mieux-avec-la-customsimple-thermostat-front-integration)
|
||||
- [Toujours mieux avec Plotly pour régler votre thermostat](#toujours-mieux-avec-plotly-pour-régler-votre-thermostat)
|
||||
- [Et toujours de mieux en mieux avec l'AappDaemon NOTIFIER pour notifier les évènements](#et-toujours-de-mieux-en-mieux-avec-laappdaemon-notifier-pour-notifier-les-évènements)
|
||||
|
||||
|
||||
## Bien mieux avec le Versatile Thermostat UI Card
|
||||
Une carte spéciale pour le Versatile Thermostat a été développée (sur la base du Better Thermostat). Elle est dispo ici [Versatile Thermostat UI Card](https://github.com/jmcollin78/versatile-thermostat-ui-card) et propose une vision moderne de tous les status du VTherm :
|
||||
|
||||

|
||||
|
||||
## Encore mieux avec le composant Scheduler !
|
||||
|
||||
Afin de profiter de toute la puissance du Versatile Thermostat, je vous invite à l'utiliser avec https://github.com/nielsfaber/scheduler-component
|
||||
En effet, le composant scheduler propose une gestion de la base climatique sur les modes prédéfinis. Cette fonctionnalité a un intérêt limité avec le thermostat générique mais elle devient très puissante avec le Versatile Thermostat :
|
||||
|
||||
À partir d'ici, je suppose que vous avez installé Versatile Thermostat et Scheduler Component.
|
||||
|
||||
Dans Scheduler, ajoutez un planning :
|
||||
|
||||

|
||||
|
||||
Choisissez le groupe "climat", choisissez une (ou plusieurs) entité(s), sélectionnez "MAKE SCHEME" et cliquez sur suivant :
|
||||
(il est possible de choisir "SET PRESET", mais je préfère utiliser "MAKE SCHEME")
|
||||
|
||||

|
||||
|
||||
Définissez votre schéma de mode et enregistrez :
|
||||
|
||||
|
||||

|
||||
|
||||
Dans cet exemple, j'ai réglé le mode ECO pendant la nuit et le jour lorsqu'il n'y a personne à la maison BOOST le matin et CONFORT le soir.
|
||||
|
||||
|
||||
J'espère que cet exemple vous aidera, n'hésitez pas à me faire part de vos retours !
|
||||
|
||||
## Encore bien mieux avec la custom:simple-thermostat front integration
|
||||
Le ``custom:simple-thermostat`` [ici](https://github.com/nervetattoo/simple-thermostat) est une excellente intégration qui permet une certaine personnalisation qui s'adapte bien à ce thermostat.
|
||||
Vous pouvez avoir quelque chose comme ça très facilement 
|
||||
Exemple de configuration :
|
||||
|
||||
```
|
||||
type: custom:simple-thermostat
|
||||
entity: climate.thermostat_sam2
|
||||
layout:
|
||||
step: row
|
||||
label:
|
||||
temperature: T°
|
||||
state: Etat
|
||||
hide:
|
||||
state: false
|
||||
control:
|
||||
hvac:
|
||||
_name: Mode
|
||||
preset:
|
||||
_name: Preset
|
||||
sensors:
|
||||
- entity: sensor.total_puissance_radiateur_sam2
|
||||
icon: mdi:lightning-bolt-outline
|
||||
header:
|
||||
toggle:
|
||||
entity: input_boolean.etat_ouverture_porte_sam
|
||||
name: Porte sam
|
||||
```
|
||||
|
||||
Vous pouvez personnaliser ce composant à l'aide du composant HACS card-mod pour ajuster les couleurs des alertes. Exemple pour afficher en rouge les alertes sécurité et délestage :
|
||||
|
||||
```
|
||||
card_mod:
|
||||
style: |
|
||||
{% if is_state('binary_sensor.thermostat_chambre_security_state', 'on') %}
|
||||
ha-card .body .sensor-heading ha-icon[icon="mdi:alert-outline"] {
|
||||
color: red;
|
||||
}
|
||||
{% endif %}
|
||||
{% if is_state('binary_sensor.thermostat_chambre_overpowering_state', 'on') %}
|
||||
ha-card .body .sensor-heading ha-icon[icon="mdi:flash"] {
|
||||
color: red;
|
||||
}
|
||||
{% endif %}
|
||||
```
|
||||

|
||||
|
||||
## Toujours mieux avec Plotly pour régler votre thermostat
|
||||
Vous pouvez obtenir une courbe comme celle présentée dans [some results](#some-results) avec une sorte de configuration de graphique Plotly uniquement en utilisant les attributs personnalisés du thermostat décrits [ici](#custom-attributes) :
|
||||
|
||||
Remplacez les valeurs entre [[ ]] par les votres.
|
||||
```
|
||||
- type: custom:plotly-graph
|
||||
entities:
|
||||
- entity: '[[climate]]'
|
||||
attribute: temperature
|
||||
yaxis: y1
|
||||
name: Consigne
|
||||
- entity: '[[climate]]'
|
||||
attribute: current_temperature
|
||||
yaxis: y1
|
||||
name: T°
|
||||
- entity: '[[climate]]'
|
||||
attribute: ema_temp
|
||||
yaxis: y1
|
||||
name: Ema
|
||||
- entity: '[[climate]]'
|
||||
attribute: regulated_target_temperature
|
||||
yaxis: y1
|
||||
name: Regulated T°
|
||||
- entity: '[[slope]]'
|
||||
name: Slope
|
||||
fill: tozeroy
|
||||
yaxis: y9
|
||||
fillcolor: rgba(100, 100, 100, 0.3)
|
||||
line:
|
||||
color: rgba(100, 100, 100, 0.9)
|
||||
hours_to_show: 4
|
||||
refresh_interval: 10
|
||||
height: 800
|
||||
config:
|
||||
scrollZoom: true
|
||||
layout:
|
||||
margin:
|
||||
r: 50
|
||||
legend:
|
||||
x: 0
|
||||
'y': 1.2
|
||||
groupclick: togglegroup
|
||||
title:
|
||||
side: top right
|
||||
yaxis:
|
||||
visible: true
|
||||
position: 0
|
||||
yaxis9:
|
||||
visible: true
|
||||
fixedrange: false
|
||||
range:
|
||||
- -0.5
|
||||
- 0.5
|
||||
position: 1
|
||||
xaxis:
|
||||
rangeselector:
|
||||
'y': 1.1
|
||||
x: 0.7
|
||||
buttons:
|
||||
- count: 1
|
||||
step: hour
|
||||
- count: 12
|
||||
step: hour
|
||||
- count: 1
|
||||
step: day
|
||||
- count: 7
|
||||
step: day
|
||||
```
|
||||
|
||||
Exemple de courbes obtenues avec Plotly :
|
||||
|
||||

|
||||
|
||||
## Et toujours de mieux en mieux avec l'AappDaemon NOTIFIER pour notifier les évènements
|
||||
Cette automatisation utilise l'excellente App Daemon nommée NOTIFIER développée par Horizon Domotique que vous trouverez en démonstration [ici](https://www.youtube.com/watch?v=chJylIK0ASo&ab_channel=HorizonDomotique) et le code est [ici](https://github.com/jlpouffier/home-assistant-config/blob/master/appdaemon/apps/notifier.py). Elle permet de notifier les utilisateurs du logement lorsqu'un des évènements touchant à la sécurité survient sur un des Versatile Thermostats.
|
||||
|
||||
C'est un excellent exemple de l'utilisation des notifications décrites ici [notification](#notifications).
|
||||
|
||||
```
|
||||
alias: Surveillance Mode Sécurité chauffage
|
||||
description: Envoi une notification si un thermostat passe en mode sécurité ou power
|
||||
trigger:
|
||||
- platform: event
|
||||
event_type: versatile_thermostat_security_event
|
||||
id: versatile_thermostat_security_event
|
||||
- platform: event
|
||||
event_type: versatile_thermostat_power_event
|
||||
id: versatile_thermostat_power_event
|
||||
- platform: event
|
||||
event_type: versatile_thermostat_temperature_event
|
||||
id: versatile_thermostat_temperature_event
|
||||
condition: []
|
||||
action:
|
||||
- choose:
|
||||
- conditions:
|
||||
- condition: trigger
|
||||
id: versatile_thermostat_security_event
|
||||
sequence:
|
||||
- event: NOTIFIER
|
||||
event_data:
|
||||
action: send_to_jmc
|
||||
title: >-
|
||||
Radiateur {{ trigger.event.data.name }} - {{
|
||||
trigger.event.data.type }} Sécurité
|
||||
message: >-
|
||||
Le radiateur {{ trigger.event.data.name }} est passé en {{
|
||||
trigger.event.data.type }} sécurité car le thermomètre ne répond
|
||||
plus.\n{{ trigger.event.data }}
|
||||
callback:
|
||||
- title: Stopper chauffage
|
||||
event: stopper_chauffage
|
||||
image_url: /media/local/alerte-securite.jpg
|
||||
click_url: /lovelace-chauffage/4
|
||||
icon: mdi:radiator-off
|
||||
tag: radiateur_security_alerte
|
||||
persistent: true
|
||||
- conditions:
|
||||
- condition: trigger
|
||||
id: versatile_thermostat_power_event
|
||||
sequence:
|
||||
- event: NOTIFIER
|
||||
event_data:
|
||||
action: send_to_jmc
|
||||
title: >-
|
||||
Radiateur {{ trigger.event.data.name }} - {{
|
||||
trigger.event.data.type }} Délestage
|
||||
message: >-
|
||||
Le radiateur {{ trigger.event.data.name }} est passé en {{
|
||||
trigger.event.data.type }} délestage car la puissance max est
|
||||
dépassée.\n{{ trigger.event.data }}
|
||||
callback:
|
||||
- title: Stopper chauffage
|
||||
event: stopper_chauffage
|
||||
image_url: /media/local/alerte-delestage.jpg
|
||||
click_url: /lovelace-chauffage/4
|
||||
icon: mdi:radiator-off
|
||||
tag: radiateur_power_alerte
|
||||
persistent: true
|
||||
- conditions:
|
||||
- condition: trigger
|
||||
id: versatile_thermostat_temperature_event
|
||||
sequence:
|
||||
- event: NOTIFIER
|
||||
event_data:
|
||||
action: send_to_jmc
|
||||
title: >-
|
||||
Le thermomètre du radiateur {{ trigger.event.data.name }} ne
|
||||
répond plus
|
||||
message: >-
|
||||
Le thermomètre du radiateur {{ trigger.event.data.name }} ne
|
||||
répond plus depuis longtemps.\n{{ trigger.event.data }}
|
||||
image_url: /media/local/thermometre-alerte.jpg
|
||||
click_url: /lovelace-chauffage/4
|
||||
icon: mdi:radiator-disabled
|
||||
tag: radiateur_thermometre_alerte
|
||||
persistent: true
|
||||
mode: queued
|
||||
max: 30
|
||||
```
|
||||
69
documentation/fr/algorithms.md
Normal file
@@ -0,0 +1,69 @@
|
||||
# Les différents algorithmes utilisés
|
||||
|
||||
- [Les différents algorithmes utilisés](#les-différents-algorithmes-utilisés)
|
||||
- [L'algorithme TPI](#lalgorithme-tpi)
|
||||
- [Configurez les coefficients de l'algorithme TPI](#configurez-les-coefficients-de-lalgorithme-tpi)
|
||||
- [Principe](#principe)
|
||||
- [L'algorithme d'auto-régulation (sans contrôle de la vanne)](#lalgorithme-dauto-régulation-sans-contrôle-de-la-vanne)
|
||||
- [L'algorithme de la fonction d'auto-start/stop](#lalgorithme-de-la-fonction-dauto-startstop)
|
||||
|
||||
## L'algorithme TPI
|
||||
|
||||
### Configurez les coefficients de l'algorithme TPI
|
||||
|
||||
Si vous avez choisi un thermostat de type ```over_switch``` ou ```over_valve``` ou `over_climate` avec l'auto-régulation `Controle direct de la vanne` et que vous sélectionnez l'option "TPI" vous menu, vous arriverez sur cette page :
|
||||
|
||||

|
||||
|
||||
Vous devez donner :
|
||||
1. le coefficient coef_int de l'algorithme TPI,
|
||||
2. le coefficient coef_ext de l'algorithme TPI
|
||||
|
||||
|
||||
### Principe
|
||||
|
||||
L'algorithme TPI consiste à calculer à chaque cycle un pourcentage d'état On vs Off pour le radiateur en utilisant la température cible, la température actuelle dans la pièce et la température extérieure actuelle. Cet algorithme n'est donc valable que pour les Versatile Thermostat qui régulent : `over_switch` et `over_valve`.
|
||||
|
||||
Le pourcentage est calculé avec cette formule :
|
||||
|
||||
on_percent = coef_int * (température cible - température actuelle) + coef_ext * (température cible - température extérieure)
|
||||
Ensuite, l'algo fait en sorte que 0 <= on_percent <= 1
|
||||
|
||||
Les valeurs par défaut pour coef_int et coef_ext sont respectivement : ``0.6`` et ``0.01``. Ces valeurs par défaut conviennent à une pièce standard bien isolée.
|
||||
|
||||
Pour régler ces coefficients, gardez à l'esprit que :
|
||||
1. **si la température cible n'est pas atteinte** après une situation stable, vous devez augmenter le ``coef_ext`` (le ``on_percent`` est trop bas),
|
||||
2. **si la température cible est dépassée** après une situation stable, vous devez diminuer le ``coef_ext`` (le ``on_percent`` est trop haut),
|
||||
3. **si l'atteinte de la température cible est trop lente**, vous pouvez augmenter le ``coef_int`` pour donner plus de puissance au réchauffeur,
|
||||
4. **si l'atteinte de la température cible est trop rapide et que des oscillations apparaissent** autour de la cible, vous pouvez diminuer le ``coef_int`` pour donner moins de puissance au radiateur.
|
||||
|
||||
En type `over_valve` le `on_percent` est ramené à une valeur entre 0 et 100% et sert directement à commander l'ouverture de la vanne.
|
||||
|
||||
## L'algorithme d'auto-régulation (sans contrôle de la vanne)
|
||||
|
||||
L'algorithme d'auto-régulation peut être synthétisé comme suit:
|
||||
|
||||
1. initialiser la température cible comme la consigne du VTherm,
|
||||
1. Si l'auto-régulation est activée,
|
||||
1. calcule de la température régulée (valable pour un VTherm),
|
||||
2. prendre cette température comme cible,
|
||||
2. Pour chaque sous-jacent du VTherm,
|
||||
1. Si "utiliser la température interne" est cochée,
|
||||
1. calcule de la compensation (trv internal temp - room temp),
|
||||
2. ajout de l'écart à la température cible,
|
||||
3. envoie de la température cible ( = temp regulee + (temp interne - temp pièce)) au sous-jacent
|
||||
|
||||
## L'algorithme de la fonction d'auto-start/stop
|
||||
|
||||
L'algorithme utilisé dans la fonction d'auto-start/stop est le suivant :
|
||||
1. if enable aut-start/stop is off, stop here.
|
||||
2. If VTherm is on and in heating mode, when error_accumulated is < -error_threshold -> turn off and save hvac mode,
|
||||
3. If VTherm is on and in Cooling mode, when error_accumulated is > error_threshold -> turn off and save hvac mode,
|
||||
4. If VTherm is off and saved hvac mode is Heating and current_temperature + slope x dt <= target_temperature then turn on and set havc mode to the saved hvac_mode,
|
||||
5. If VTherm is off and saved hvac mode is Cooling and current_temperature + slope x dt >= target_temperature then turn on and set havc mode to the saved hvac_mode
|
||||
6. error_threshold is set to respectively 10 (° * min) in slow, 5 in medium and 2 in fast.
|
||||
|
||||
dt is set to respectively 30 min in slow, 15 min in medium and 7 min in fast detection level.
|
||||
|
||||
La fonction est décrite dans le détail [ici](https://github.com/jmcollin78/versatile_thermostat/issues/585).
|
||||
|
||||
43
documentation/fr/base-attributes.md
Normal file
@@ -0,0 +1,43 @@
|
||||
# Choix des attributs de base
|
||||
|
||||
Choisisez le menu "Principaux attributs".
|
||||
|
||||

|
||||
|
||||
Donnez les principaux attributs obligatoires. Ces attributs sont communs à tous les VTherms :
|
||||
1. un nom (sera le nom de l'intégration et aussi le nom de l'entité `climate`)
|
||||
4. un identifiant d'entité de capteur de température qui donne la température de la pièce dans laquelle le radiateur est installé,
|
||||
5. une entité facultative de capteur de donnant la date et heure de dernière vue du capteur (`last_seen`). Si vous avez ce capteur donnez le ici, il permet d'éviter des mises en sécurité lorsque la température est stable et que le capteur ne remonte plus de température pendant longtemps. (cf. [ici](troubleshooting.md#pourquoi-mon-versatile-thermostat-se-met-en-securite-)),
|
||||
6. une durée de cycle en minutes. A chaque cycle :
|
||||
1. `over_switch` : VTherm allumera/éteindra le radiateur en modulant la proportion de temps allumé,
|
||||
2. `over_valve` : VTherm calculera une nouvelle ouverture de la vanne et lui enverra si elle a changée,
|
||||
3. `over_climate` : le cycle permet d'effectuer les contrôles de base et recalcule les coefficients de l'auto-régulation. Le cycle peut déboucher sur une nouvelle consigne envoyée au sous-jacents ou sur une modification d'ouverture de la vanne dans le cas d'un _TRV_ dont la vanne est commandable.
|
||||
7. une puissance de l'équipement ce qui va activer les capteurs de puissance et énergie consommée par l'appareil. Si plusieurs équipements sont reliés au même VTherm, il faut indiquer ici le total des puissances max des équipements,
|
||||
8. la possibilité d'utiliser des paramètres complémentaires venant de la configuration centralisée :
|
||||
1. capteur de température extérieure,
|
||||
2. température minimale / maximale et pas de température
|
||||
9. la possibilité de controler le thermostat de façon centralisée. Cf [controle centralisé](#le-contrôle-centralisé),
|
||||
10. une case à cocher si ce VTherm est utilisé pour déclencher une éventuelle chaudière centrale.
|
||||
|
||||
>  _*Notes*_
|
||||
> 1. avec les types ```over_switch``` et ```over_valve```, les calculs sont effectués à chaque cycle. Donc en cas de changement de conditions, il faudra attendre le prochain cycle pour voir un changement. Pour cette raison, le cycle ne doit pas être trop long. **5 min est une bonne valeur** mais doit être adapté à votre type de chauffage. Plus l'inertie est grande et plus le cycle doit être long. Cf. 'TODO exemples de reglages,
|
||||
> 2. si le cycle est trop court, le radiateur ne pourra jamais atteindre la température cible. Pour le radiateur à accumulation par exemple il sera sollicité inutilement.
|
||||
|
||||
# Choix des fonctions utilisées
|
||||
|
||||
Choisissez le menu "Fonctions".
|
||||
|
||||

|
||||
|
||||
Les différentes fonctions que vous souhaitez utiliser pour ce VTherm :
|
||||
1. la détection d'ouvertures (portes, fenêtres) permettant de stopper le chauffage lorsque l'ouverture est ouverte. (cf. [gestion des ouvertures](feature-window.md))
|
||||
2. la détection de mouvement : VTherm peut adapter une consigne de température lorsqu'un mouvement est détecté dans la pièce. (cf. [détection du mouvement](feature-motion.md))
|
||||
3. la gestion de la puissance : VTherm peut stopper un équipement si la puissance consommée dans votre habitation dépasse un seuil. (cf. [gestion du délestage](feature-power.md))
|
||||
4. la détection de présence : si vous avez un capteur indiquant une présence ou non dans votre habitation, vous pouvez l'utiliser pour changer la température de consigne. Cf. [gestion de la présence](feature-presence.md). Attention de ne pas confondre cette fonction avec la détection de mouvement. La présence est plus faite pour être à l'échelle de l'habitation alors que le mouvement est plus fait pour être à l'échelle de la pièce.
|
||||
5. l'arrêt/démarrage automatique : pour les VTherm de type `over_climate` uniquement. Cette fonction permet d'arrêter un équipement lorsque VTherm détete qu'il ne sera plus néessaire pendant un certain temps. Il utilise la courbe de température pour prévoir quand l'équipement sera de nouveau utile et le rallumera à ce moment là. Cf. [gestion de l'arrêt/démarrage automatique](feature-auto-start-stop.md)
|
||||
|
||||
|
||||
>  _*Notes*_
|
||||
> 1. La liste des fonctions disponibles s'adapte à votre type de VTherm.
|
||||
> 2. Lorsque vous cochez une fonction, une nouvelle entrée menu s'ajoute pour configurer la fonction.
|
||||
> 3. Vous ne pourrez pas valider la création d'un VTherm si tous les paramètres de toutes les fonctions n'ont pas été saisis.
|
||||
61
documentation/fr/creation.md
Normal file
@@ -0,0 +1,61 @@
|
||||
# Choix du Vtherm
|
||||
|
||||
>  _*Notes*_
|
||||
>
|
||||
> Trois façons de travailler avec les VTherms sont disponibles :
|
||||
> 1. Chaque Versatile Thermostat est entièrement configurée de manière indépendante. Choisissez cette option si vous ne souhaitez avoir aucune configuration ou gestion centrale.
|
||||
> 2. Certains aspects sont configurés de manière centralisée. Cela permet par ex. définir la température min/max, la détection de fenêtre ouverte,… au niveau d'une instance centrale et unique. Pour chaque VTherm que vous configurez, vous pouvez alors choisir d'utiliser la configuration centrale ou de la remplacer par des paramètres personnalisés.
|
||||
> 3. En plus de cette configuration centralisée, tous les VTherm peuvent être contrôlées par une seule entité de type `select`. Cette fonction est nommé `central_mode`. Cela permet de stopper / démarrer / mettre en hors gel / etc tous les VTherms en une seule fois. Pour chaque VTherm, l'utilisateur indique si il est concerné par ce `central_mode`.
|
||||
|
||||
|
||||
## Création d'un nouveau Versatile Thermostat
|
||||
|
||||
Cliquez sur le bouton Ajouter une intégration dans la page d'intégration
|
||||
|
||||

|
||||
|
||||
puis
|
||||
|
||||

|
||||
|
||||
La configuration peut être modifiée via la même interface. Sélectionnez simplement le thermostat à modifier, appuyez sur "Configurer" et vous pourrez modifier certains paramètres ou la configuration.
|
||||
|
||||
Suivez ensuite les étapes de configuration en sélectionnant dans le menu l'option à configurer.
|
||||
|
||||
# Choix d'un type de VTherm
|
||||
|
||||
## Configuration centralisée
|
||||
Ce choix permet de configurer une fois pour tous les VTherms certains aspects qui peuvent être répétitifs comme :
|
||||
1. les paramètres des différents algorithmes (TPI, détection d'ouvertures, détection de mouvements, capteurs de puissance de votre habitation, la détection de présence). Tous ces paramètres sont transverses à tous les VTherms. Vous pouvez donc ne les saisir qu'une seule fois dans la `Configuration centralisée`. Cette configuration ne créé pas de VTherm à proprement parler. Elle permet juste de mettre en commun des paramètres qu'il serait fastidieux de resaisir pour chaque VTherm. Noter que vous pouvez surcharger les paramètres sur les VTherms pour les spécialisés au besoin,
|
||||
2. la configuration de la commande d'un chauffage central,
|
||||
3. certains paramètre avancés comme la mise en sécurité
|
||||
|
||||
## VTherm sur un switch
|
||||
Ce VTherm permet de contrôler un interrupteur qui allume ou étient un radiateur. Cet interrupteur peut être un interrupteur physique qui allume ou éteint directement un radiateur (souvent électrique) ou un interrupteur virtuel qui pourra effectuer les actions que vous voulez sur demande d'allumage ou extinction. Ce dernier type permet par exemple de commander des switchs avec fil pilote ou deu DIY avec diode pour fil pilote. VTherm va moduler la proportion de temps allumé vs éteint pour obtenir la température souhaitée. Si il fait froid, il allume plus souvent (jusqu'à 100%), si il fait chaud il baisse le pourcentage d'allumage. Ce pourcentage d'allumage en nommé `on_percent`.
|
||||
|
||||
Les entités sous-jacentes sont donc des `switchs` ou des `input_boolean`.
|
||||
|
||||
## Vtherm sur un autre thermostat
|
||||
Lorsque votre équipement est contrôlé par une entité de type `climate` dans Home Assistant et que vous n'avez que ça à disposition, vous devez utiliser ce type de VTherm. Dans ce cas, le VTherm va simplement commander la température de consigne du `climate` sous-jacent.
|
||||
Ce type est aussi équipé de fonction d' auto-régulations avancées permettant de moduler la consigne donnée aux sous-jacent pour atteindre plus vite la consigne et de s'affranchir de la régulation interne de ces équipements qui est parfois mauvaise. C'est le cas, si le thermomètre interne de l'équipement est trop proche du corps de chauffe. L'équipement peut croire qu'il fait chaud alors qu'au bout de la pièce, la consigne n'est pas du tout atteinte.
|
||||
|
||||
Depuis la version 6.8, ce type de VTherm permet aussi de réguler avec une action directe sur la vanne. Idéal pour les _TRV_ pour lesquels la vanne est commandable, ce type est recommandé si vous êtes équipés.
|
||||
|
||||
Les entités sous-jacentes de ce type de VTherm sont donc des `climate` exclusivement.
|
||||
|
||||
## VTherm sur une vanne
|
||||
Lorsque tout ce que vous avez à disposition pour réguler la température de votre radiateur est une entité de type `number` vous devez utiliser le type `over_valve`. VTherm ouvre ou ferme la vanne en fonction de l'écart entre la consigne et la température réelle de la pièce (et de la température extérieure).
|
||||
|
||||
Ce type peut être utilisé pour les _TRV_ qui n'ont pas de `climate` associé ou tout autre solution type DIY qui expose une entité `number`.
|
||||
|
||||
# Le bon choix
|
||||
>  _*Comment choisir le type*_
|
||||
> Le choix du type est important. Il n'est plus possible de le modifier via l'IHM de configuration. Pour bien chsoisir, il faut se poser les quelques questions suivantes :
|
||||
> 1. **quel type d'équipement je vais piloter ?** Dans l'ordre voici ce qu'il faut faire :
|
||||
> 1. si vous avez une vanne thermostatique (_TRV_) commandable dans Home Assistant via une entité de type ```number``` (par exemple une _Shelly TRV_), choisissez le type `over_valve`. C'est le type le plus direct et qui assure la meilleure régulation,
|
||||
> 2. si vous avez un radiateur électrique (avec ou sans fil pilote) et qu'une entité de type ```switch``` permet de l'allumer ou de l'éteindre, alors le type ```over_switch``` est préférable. La régulation sera faite par le Versatile Thermostat en fonction de la température mesuré par votre thermomètre, à l'endroit ou vous l'avez placé,
|
||||
> 3. dans tous les autres cas, utilisez le mode ```over_climate```. Vous gardez votre entité ```climate``` d'origine et le Versatile Thermostat "ne fait que" piloter le on/off et la température cible de votre thermostat d'origine. La régulation est faite par votre thermostat d'origine dans ce cas. Ce mode est particulièrement adapté aux climatisations réversible tout-en-un dont l'exposition dans Home Assistant se limite à une entité de type ```climate```. Une auto-régulation avancée permet d'atteindre la consigne en forçant la consigne ou un pilotant directement la vanne lorsque c'est possible.
|
||||
> 2. **quelle type de régulation je veux ?** Si l'équipement piloté possède son propre mécanisme de régulation (clim, certaine vanne TRV) et que cette régulation fonctionne bien, optez pour un ```over_climate```. Si l'équipement est de type _TRV_ avec une vanne pilotable sous HA, alors le type `over_climate` avec une auto-régulation `Contrôle direct de la vanne` est le meilleur choix.
|
||||
|
||||
# Article en référence
|
||||
Un article permettant d'aller plus loin sur les concepts est visible ici (en Français) : https://www.hacf.fr/optimisation-versatile-thermostat/#optimiser-vos-vtherm
|
||||
51
documentation/fr/feature-advanced.md
Normal file
@@ -0,0 +1,51 @@
|
||||
# La configuration avancée
|
||||
|
||||
- [La configuration avancée](#la-configuration-avancée)
|
||||
- [Configuration avancée](#configuration-avancée)
|
||||
- [Délai minimal d'activation](#délai-minimal-dactivation)
|
||||
- [La mise en sécurité](#la-mise-en-sécurité)
|
||||
|
||||
Ces paramètres permettent d'affiner le fonctionnement du thermostat et notamment la mise en sécurité d'un _VTherm_. L'absence d'un capteur de température (pièce ou extérieur) peut être dangereux pour votre logement. Supposez que le capteur de température soit bloqué sur 10°. Le _VTherm_ de type `over_climate` ou `over_valve` va alors commander un chauffage maximal des équipements sous-jacents, ce qui peut conduire à une surchauffe de la pièce voire des dommages sur le logement avec au pire un début d'incendie.
|
||||
|
||||
Pour éviter cela, _VTherm_ s'assure que les thermomètres répondent bien de façon régulière et met le _VTherm_ dans un mode particuliers nommée le mode sécurité si ce n'est plus le cas. Le mode sécurité consiste à assurer un minimum de chauffe pour éviter l'effet inverse : une habitation qui ne serait plus chauffée du tout en plein hiver par exemple.
|
||||
|
||||
Là où le problème devient compliqué, c'est que certain thermomètre - notamment à pile - n'envoie leur température que si elle change. Il est donc tout à fait possible de ne plus recevoir de mises à jour de température pendant plusieurs heures sans que le thermomètre soit en défaut. Les différents paramètres ci-dessous vont permettre de régler finement les seuils de passage en mode sécurité.
|
||||
|
||||
Si votre thermomètre est muni d'un capteur nommé `last seen` qui donne l'heure de son dernier contact, il est possible de le spécifier dans les attributs principaux du _VTherm_ pour limiter grandement les fausses mises en sécurité. Cf. [configuration](base-attributes.md#choix-des-attributs-de-base) et [dépannage](troubleshooting.md#pourquoi-mon-versatile-thermostat-se-met-en-securite-).
|
||||
|
||||
Pour les _VTherm_ `over_climate` et donc qui se régule lui-même, le mode sécurité est désactivé. En effet il n'y a pas de risque de danger si l'équipement se régule lui-même mais juste un risque de mauvaise température.
|
||||
|
||||
## Configuration avancée
|
||||
|
||||
Le formulaire de configuration avancée est le suivant :
|
||||
|
||||

|
||||
|
||||
### Délai minimal d'activation
|
||||
|
||||
Le premier délai (`minimal_activation_delay_sec`) en secondes est le délai minimum acceptable pour allumer le chauffage. Lorsque le calcul donne un délai de mise sous tension inférieur à cette valeur, le chauffage reste éteint. Ce paramètre ne sert qu'au _VTherm_ avec un déclenchement cyclique `over_switch`. Si le temps d'allumage est trop court, la, commutation rapide ne permettra pas à l'équipement de monter en température.
|
||||
|
||||
### La mise en sécurité
|
||||
|
||||
Le deuxième délai (`security_delay_min`) est le délai maximal entre deux mesures de température avant de passer le _VTherm_ en mode sécurité.
|
||||
|
||||
Le troisième paramètre (`security_min_on_percent`) est la valeur minimal de `on_percent` en dessous de laquelle le préréglage sécurité ne sera pas activé. Ce paramètre permet de ne pas mettre en sécurité un thermostat, si le radiateur piloté ne chauffe pas suffisament. En effet, il n'y a pas de risque physique pour le logement dans ce cas mais juste un risque de surchauffe ou de sous-chauffe.
|
||||
Mettre ce paramètre à ``0.00`` déclenchera le préréglage sécurité quelque soit la dernière consigne de chauffage, à l'inverse ``1.00`` ne déclenchera jamais le préréglage sécurité ( ce qui revient à désactiver la fonction). Ce peut ê
|
||||
|
||||
Le quatrième paramètre (`security_default_on_percent`) est la valeur de `on_percent` qui sera utilisée lorsque le thermostat passe en mode ``security``. Si vous mettez `0` alors le thermostat sera coupé lorsqu'il passe en mode `security`, mettre 0,2% par exemple permet de garder un peu de chauffage (20% dans ce cas), même en mode ``security``. Ca évite de retrouver son logement totalement gelé lors d'une panne de thermomètre.
|
||||
|
||||
Il est possible de désactiver la mise en sécurité suite à une absence de données du thermomètre extérieure. En effet, celui-ci ayant la plupart du temps un impact faible sur la régulation (dépendant de votre paramètrage), il est possible qu'il soit absent sans mettre en danger le logement. Pour cela, il faut ajouter les lignes suivantes dans votre `configuration.yaml` :
|
||||
```
|
||||
versatile_thermostat:
|
||||
...
|
||||
safety_mode:
|
||||
check_outdoor_sensor: false
|
||||
```
|
||||
Par défaut, le thermomètre extérieur peut déclencher une mise en sécurité si il n'envoit plus de valeur. N'oubliez pas que Home Assisstant doit être redémarré pour que ces modifications soient prises en compte. Ce réglage est commun à tous les _VTherm_ (qui devraient partager le thermomètre extérieur.
|
||||
|
||||
>  _*Notes*_
|
||||
> 1. Lorsque le capteur de température viendra à la vie et renverra les températures, le préréglage sera restauré à sa valeur précédente,
|
||||
> 2. Attention, deux températures sont nécessaires : la température interne et la température externe et chacune doit donner la température, sinon le thermostat sera en préréglage "security",
|
||||
> 3. Une action est disponible qui permet de régler les 3 paramètres de sécurité. Ca peut servir à adapter la fonction de sécurité à votre usage,
|
||||
> 4. Pour un usage naturel, le ``security_default_on_percent`` doit être inférieur à ``security_min_on_percent``,
|
||||
> 5. Si vous utilisez la carte Verstatile Thermostat UI (cf. [ici](additions.md#bien-mieux-avec-le-versatile-thermostat-ui-card)), un _Vtherm_ en mode sécurité est signalé par un voile grisatre qui donne le thermomètre en défaut et depuis combien de temps le thermomètre n'a pas remonté de valeur : .
|
||||
41
documentation/fr/feature-auto-start-stop.md
Normal file
@@ -0,0 +1,41 @@
|
||||
# Le démarrage / arrêt automatique (auto-start/stop)
|
||||
|
||||
- [Le démarrage / arrêt automatique (auto-start/stop)](#le-démarrage--arrêt-automatique-auto-startstop)
|
||||
- [Configurer l'auto-start/stop](#configurer-lauto-startstop)
|
||||
- [Usage](#usage)
|
||||
|
||||
Cette fonction permet d'autoriser VTherm a stopper un équipement qui n'a pas besoin d'être allumé et de le redémarrer lorsque les conditions le réclame. Cette fonction est munie de 3 réglages qui permettent d'arrêter / relancer plus ou moins rapidement l'équipement.
|
||||
Exclusiveme réservé au _VTherm_ de type `over_climate`, elle répond au cas d'usage suivant :
|
||||
1. votre équipement est allumé électriquement en permanence et consomme de l'électricité même lorsqu'il n'y a pas besoin de chauffer (resp. refroidir). C'est souvent le cas sur les _PAC_ qui consomment même en veille,
|
||||
2. les conditions de température font qu'il n'y a pas besoin de chauffer (resP. refroidir) pendant longtemps : la consigne est supérieure (resp. inférieur) à la température de la pièce,
|
||||
3. la température monte (resp. descend), est stable ou descend (resp. monte) doucement
|
||||
|
||||
Dans ce cas, il est préférable de demander à l'équipement de s'éteindre pour éviter la consommation électrique en mode veille.
|
||||
|
||||
## Configurer l'auto-start/stop
|
||||
|
||||
|
||||
Pour l'utiliser, vous devez :
|
||||
1. Ajouter la fonction `Avec démmarrage et extinction automatique` dans le menu 'Fonctions',
|
||||
2. Paramétrer le niveau de détection dans l'option 'Allumage/extinction automatique' qui s'affiche lorsque la fonction a été activée. Vous choisissez le niveau de détection entre 'Lent', 'Moyen' et 'Rapide'. Les arrêts/relances seront plus nombreux avec le niveau 'Rapide'.
|
||||
|
||||

|
||||
|
||||
Le réglage 'Lent' permet d'avoir environ 30 min entre un arrêt et une relance,
|
||||
Le réglage 'Moyen' met le seuil a environ 15 min et le réglage rapide le met à 7 min.
|
||||
|
||||
Attention, ce ne sont pas des réglages absolus puisque l'algorithme tient compte de la pente de la courbe température de la pièce pour réagir. Il est toujours possible qu'un démarrage ait lieu peu après une extinction si la chute de température est importante.
|
||||
|
||||
## Usage
|
||||
|
||||
Une fois la fonction paramétrée, vous aurez maintenant une nouvelle entité de type `switch` qui vous permet d'autoriser ou non l'arrêt/relance automatique sans toucher à la configuration. Cette entité est disponible sur l'appareil VTherm et se nomme `switch.<name>_enable_auto_start_stop`.
|
||||
|
||||

|
||||
|
||||
Cochez la pour autoriser le démarrage et extinction automatique et laissez là décocher si vous voulez désactiver la fonction auto-start/stop.
|
||||
|
||||
|
||||
>  _*Notes*_
|
||||
> 1. L'algorithme de détection est décrit [ici](algorithms.md#lalgorithme-de-la-fonction-dauto-startstop).
|
||||
> 2. Certains équipements (chaudière, chauffage au sol, _PAC_, ...) n'aiment pas forcément être arrêtés / stoppés trop souvent. Si vous êtes dans ce cas, il peut être préférable de desactiver la fonction lorsque vous savez qu'il va être utilisé. Par exemple, je désactive cette fonction en journée si il y a une présence de détectée car je sais que ma _PAC_ va s'allumer souvent. J'autorise l'auto-start/stop la nuit ou en cas d'absence puisque la consigne est abaissée et qu'elle se déclenche peu voir pas du tout.
|
||||
> 3. Si vous utilisez la carte Verstatile Thermostat UI (cf. [ici](additions.md#bien-mieux-avec-le-versatile-thermostat-ui-card)), une case à cocher est directement visible sur la carte pour désactiver l'auto-start/stop et un _Vtherm_ stoppé par l'auto-start/stop est signalé par l'icone : .
|
||||
109
documentation/fr/feature-central-boiler.md
Normal file
@@ -0,0 +1,109 @@
|
||||
# Le contrôle d'une chaudière centrale
|
||||
|
||||
- [Le contrôle d'une chaudière centrale](#le-contrôle-dune-chaudière-centrale)
|
||||
- [Principe](#principe)
|
||||
- [Configuration](#configuration)
|
||||
- [Comment trouver la bonne action ?](#comment-trouver-la-bonne-action-)
|
||||
- [Les évènements](#les-évènements)
|
||||
- [Avertissement](#avertissement)
|
||||
|
||||
Vous avez la possibilité de contrôler une chaudière centralisée. A partir du moment où il est possible de déclencher ou stopper cette chaudière depuis Home Assistant, alors Versatile Thermostat va pouvoir la commander directement.
|
||||
|
||||
## Principe
|
||||
Le principe mis en place est globalement le suivant :
|
||||
1. une nouvelle entité de type `binary_sensor` et nommée par défaut `binary_sensor.central_boiler` est ajoutée,
|
||||
2. dans la configuration des VTherms vous indiquez si le VTherm doit contrôler la chaudière. En effet, dans une installation hétérogène, certains VTherm doivent commander la chaudière et d'autres non. Vous devez donc indiquer dans chaque configuration de VTherm si il contrôle la chaudière ou pas,
|
||||
3. le `binary_sensor.central_boiler` écoute les changements d'états des équipements des VTherm marqués comme contrôlant la chaudière,
|
||||
4. dès que le nombre d'équipements pilotés par le VTherm demandant du chauffage (ie son `hvac_action` passe à `Heating`) dépasse un seuil paramétrable, alors le `binary_sensor.central_boiler` passe à `on` et **si un service d'activation a été configuré, alors ce service est appelé**,
|
||||
5. si le nombre d'équipements nécessitant du chauffage repasse en dessous du seuil, alors le `binary_sensor.central_boiler` passe à `off` et si **un service de désactivation a été configuré, alors ce service est appelé**,
|
||||
6. vous avez accès à deux entités :
|
||||
- une de type `number` nommé par défaut `number.boiler_activation_threshold`, donne le seuil de déclenchement. Ce seuil est en nombre d'équipements (radiateurs) qui demande du chauffage.
|
||||
- une de type `sensor` nommé par défaut `sensor.nb_device_active_for_boiler`, donne le nombre d'équipements qui demande du chauffage. Par exemple, un VTherm ayant 4 vannes dont 3 demandes du chauffage fera passé ce capteur à 3. Seuls les équipements des VTherms qui sont marqués pour contrôler la chaudière centrale sont comptabilisés.
|
||||
|
||||
Vous avez donc en permanence, les informations qui permettent de piloter et régler le déclenchement de la chaudière.
|
||||
|
||||
Toutes ces entités sont rattachés au service de configuration centrale :
|
||||
|
||||

|
||||
|
||||
## Configuration
|
||||
Pour configurer cette fonction, vous devez avoir une configuration centralisée (cf. [Configuration](#configuration)) et cochez la case 'Ajouter une chaudière centrale' :
|
||||
|
||||

|
||||
|
||||
Sur la page suivante vous pouvez donner la configuration des actions (ex services) à appeler lors de l'allumage / extinction de la chaudière :
|
||||
|
||||

|
||||
|
||||
Les actions (ex services) se configurent comme indiqués dans la page :
|
||||
1. le format général est `entity_id/service_id[/attribut:valeur]` (où `/attribut:valeur` est facultatif),
|
||||
2. `entity_id` est le nom de l'entité qui commande la chaudière sous la forme `domain.entity_name`. Par exemple: `switch.chaudiere` pour les chaudière commandée par un switch ou `climate.chaudière` pour une chaudière commandée par un thermostat ou tout autre entité qui permet le contrôle de la chaudière (il n'y a pas de limitation). On peut aussi commuter des entrées (`helpers`) comme des `input_boolean` ou `input_number`.
|
||||
3. `service_id` est le nom du service à appeler sous la forme `domain.service_name`. Par exemple: `switch.turn_on`, `switch.turn_off`, `climate.set_temperature`, `climate.set_hvac_mode` sont des exemples valides.
|
||||
4. pour certain service vous aurez besoin d'un paramètre. Cela peut être le 'Mode CVC' `climate.set_hvac_mode` ou la température cible pour `climate.set_temperature`. Ce paramètre doit être configuré sous la forme `attribut:valeur` en fin de chaine.
|
||||
|
||||
Exemples (à ajuster à votre cas) :
|
||||
- `climate.chaudiere/climate.set_hvac_mode/hvac_mode:heat` : pour allumer le thermostat de la chaudière en mode chauffage,
|
||||
- `climate.chaudiere/climate.set_hvac_mode/hvac_mode:off` : pour stopper le thermostat de la chaudière,
|
||||
- `switch.pompe_chaudiere/switch.turn_on` : pour allumer le swicth qui alimente la pompe de la chaudière,
|
||||
- `switch.pompe_chaudiere/switch.turn_off` : pour allumer le swicth qui alimente la pompe de la chaudière,
|
||||
- ...
|
||||
|
||||
### Comment trouver la bonne action ?
|
||||
Pour trouver l'action à utiliser, le mieux est d'aller dans "Outils de développement / Actions", chercher l'action à appeler, l'entité à commander et l'éventuel paramètre à donner.
|
||||
Cliquez sur 'Appeler l'action'. Si votre chaudière s'allume vous avez la bonne configuration. Passez alors en mode Yaml et recopiez les paramètres.
|
||||
|
||||
Exemple:
|
||||
|
||||
Sous "Outils de développement / Service" :
|
||||
|
||||

|
||||
|
||||
En mode yaml :
|
||||
|
||||

|
||||
|
||||
Le service à configurer est alors le suivant: `climate.empty_thermostast/climate.set_hvac_mode/hvac_mode:heat` (notez la suppression du blanc dans `hvac_mode:heat`)
|
||||
|
||||
Faite alors de même pour le service d'extinction et vous êtes parés.
|
||||
|
||||
## Les évènements
|
||||
|
||||
A chaque allumage ou extinction réussie de la chaudière un évènement est envoyé par Versatile Thermostat. Il peut avantageusement être capté par une automatisation, par exemple pour notifier un changement.
|
||||
Les évènements ressemblent à ça :
|
||||
|
||||
Un évènement d'allumage :
|
||||
```
|
||||
event_type: versatile_thermostat_central_boiler_event
|
||||
data:
|
||||
central_boiler: true
|
||||
entity_id: binary_sensor.central_boiler
|
||||
name: Central boiler
|
||||
state_attributes: null
|
||||
origin: LOCAL
|
||||
time_fired: "2024-01-14T11:33:52.342026+00:00"
|
||||
context:
|
||||
id: 01HM3VZRJP3WYYWPNSDAFARW1T
|
||||
parent_id: null
|
||||
user_id: null
|
||||
```
|
||||
|
||||
Un évènement d'extinction :
|
||||
```
|
||||
event_type: versatile_thermostat_central_boiler_event
|
||||
data:
|
||||
central_boiler: false
|
||||
entity_id: binary_sensor.central_boiler
|
||||
name: Central boiler
|
||||
state_attributes: null
|
||||
origin: LOCAL
|
||||
time_fired: "2024-01-14T11:43:52.342026+00:00"
|
||||
context:
|
||||
id: 01HM3VZRJP3WYYWPNSDAFBRW1T
|
||||
parent_id: null
|
||||
user_id: null
|
||||
```
|
||||
|
||||
## Avertissement
|
||||
|
||||
>  _*Notes*_
|
||||
> Le contrôle par du logiciel ou du matériel de type domotique d'une chaudière centrale peut induire des risques pour son bon fonctionnement. Assurez-vous avant d'utiliser ces fonctions, que votre chaudière possède bien des fonctions de sécurité et que celles-ci fonctionnent. Allumer une chaudière si tous les robinets sont fermés peut générer de la sur-pression par exemple.
|
||||
32
documentation/fr/feature-central-mode.md
Normal file
@@ -0,0 +1,32 @@
|
||||
|
||||
# Le contrôle centralisé
|
||||
|
||||
- [Le contrôle centralisé](#le-contrôle-centralisé)
|
||||
- [Configuration du contrôle centralisée](#configuration-du-contrôle-centralisée)
|
||||
- [Usage](#usage)
|
||||
|
||||
Cette fonction vous permet de contrôler tous vos _VTherm_ depuis un unique point de contrôle.
|
||||
Le cas d'usage typique est lorsque vous partez pour une longue durée, vous voulez mettre tous vos _VTherm_ en Hors-gel et lorsque vous rentrez, vous voulez les remettre dans l'état initial.
|
||||
|
||||
Le contrôle centralisé se fait depuis un _Vtherm_ spécial nommé configuration centralisée. Cf. [ici](creation.md#configuration-centralisée) pour plus d'informations.
|
||||
|
||||
## Configuration du contrôle centralisée
|
||||
|
||||
Si vous avez défini une configuration centralisée, vous avez une nouvelle entité nommée `select.central_mode` qui permet de piloter tous les VTherms avec une seule action.
|
||||
|
||||

|
||||
|
||||
Cette entité se présente sous la forme d'une liste de choix qui contient les choix suivants :
|
||||
1. `Auto` : le mode 'normal' dans lequel chaque VTherm se comporte de façon autonome,
|
||||
2. `Stooped` : tous les VTherms sont mis à l'arrêt (`hvac_off`),
|
||||
3. `Heat only` : tous les VTherms sont mis en mode chauffage lorsque ce mode est supporté par le VTherm, sinon il est stoppé,
|
||||
4. `Cool only` : tous les VTherms sont mis en mode climatisation lorsque ce mode est supporté par le VTherm, sinon il est stoppé,
|
||||
5. `Frost protection` : tous les VTherms sont mis en preset hors-gel lorsque ce preset est supporté par le VTherm, sinon il est stoppé.
|
||||
|
||||
## Usage
|
||||
|
||||
Pour qu'un VTherm soit contrôlable de façon centralisée, il faut que son attribut de configuration nommé `use_central_mode` soit vrai. Cet attribut est disponible dans la page de configuration `Principaux ttributs`
|
||||
|
||||

|
||||
|
||||
Il est donc possible de contrôler tous les VTherms (que ceux que l'on désigne explicitement) avec un seul contrôle.
|
||||
40
documentation/fr/feature-motion.md
Normal file
@@ -0,0 +1,40 @@
|
||||
# La détection de mouvement ou d'activité
|
||||
|
||||
- [La détection de mouvement ou d'activité](#la-détection-de-mouvement-ou-dactivité)
|
||||
- [Configurer le mode d'activité ou la détection de mouvement](#configurer-le-mode-dactivité-ou-la-détection-de-mouvement)
|
||||
- [Usage](#usage)
|
||||
|
||||
Cette fonction vous permet de changer de preset lorsqu'un mouvement est détectée dans une pièce. Si vous ne souhaitez chauffer votre bureau, lorsque la pièce est occupée et uniquement si la pièce est occupée, il vous faut un capteur de mouvement (ou de présence) dans la pièce et configurer cette fonction.
|
||||
|
||||
Cette fonction est souvent confondue avec la fonction de présence. Elles sont complémentaires mais ne se remplace pas. La fonction 'mouvement' est locale à une pièce équipe d'un capteur de mouvement alors que la fonction 'présence' est prévue pour être globale à tout le logement.
|
||||
|
||||
## Configurer le mode d'activité ou la détection de mouvement
|
||||
|
||||
Si vous avez choisi la fonctionnalité `Avec détection de mouvement`, :
|
||||
|
||||

|
||||
|
||||
Ce dont nous avons besoin:
|
||||
- un **capteur de mouvement**. ID d'entité d'un capteur de mouvement. Les états du capteur de mouvement doivent être « on » (mouvement détecté) ou « off » (aucun mouvement détecté)
|
||||
- une durée de **délai d'activation** (en secondes) définissant combien de temps nous attendons la confirmation du mouvement avant de considérer le mouvement. Ce paramètre peut être **supérieur à la temporisation de votre détecteur de mouvement**, sinon la détection se fera à chaque mouvement signalé par le détecteur,
|
||||
- une durée de fin **délai de désactivation** (en secondes) définissant combien de temps nous attendons la confirmation d'une fin de mouvement avant de ne plus considérer le mouvement.
|
||||
- un **préréglage de "mouvement"**. Nous utiliserons la température de ce préréglage lorsqu'une activité sera détectée.
|
||||
- un **préréglage "pas de mouvement"**. Nous utiliserons la température de ce deuxième préréglage lorsqu'aucune activité n'est détectée.
|
||||
|
||||
## Usage
|
||||
|
||||
Pour indiquer à un _VTherm_ qu'il doit écouter le capteur de mouvement, vous devez le mettre dans le preset spécial 'Activité'. Si vous avez installé la carte Versatile Thermostat UI (cf. [ici](additions.md#bien-mieux-avec-le-versatile-thermostat-ui-card)), ce preset est représenté comme suit : .
|
||||
|
||||
Vous pouvez ainsi, sur demande, mettre un _VTherm_ en mode détection de mouvement.
|
||||
|
||||
Le comportement va être le suivant :
|
||||
- nous avons une pièce avec un thermostat réglé en mode activité, le mode "mouvement" choisi est confort (21,5°C), le mode "pas de mouvement" choisi est Eco (18.5°C) et la temporisation du mouvement est de 30 sec lors de la détection et de 5 minutes sur fin de détection.
|
||||
- la pièce est vide depuis un moment (aucune activité détectée), la température de consigne de cette pièce est de 18,5°
|
||||
- quelqu'un entre dans la pièce, une activité est détectée si le mouvement est présent pendant au moins 30 sec. La température passe alors à 21,5°
|
||||
- si le mouvement est présent pendant moins de 30 sec (passage rapide), la température reste sur 18,5°,
|
||||
- imaginons que la température soit passée sur 21,5°, lorsque la personne quitte la pièce, au bout de 5 min la température est ramenée à 18,5°.
|
||||
- si la personne revient avant les 5 minutes, la température reste sur 21,5°
|
||||
|
||||
>  _*Notes*_
|
||||
> 1. Sachez que comme pour les autres preset, `Activité` ne sera proposé que s'il est correctement configuré. En d'autres termes, les 4 clés de configuration doivent être définies
|
||||
> 2. Si vous utilisez la carte Verstatile Thermostat UI (cf. [ici](additions.md#bien-mieux-avec-le-versatile-thermostat-ui-card)), une détection de mouvement est représenté comme suit : .
|
||||
44
documentation/fr/feature-power.md
Normal file
@@ -0,0 +1,44 @@
|
||||
# Gestion de la puissance - délestage
|
||||
|
||||
- [Gestion de la puissance - délestage](#gestion-de-la-puissance---délestage)
|
||||
- [Configurer la gestion de la puissance](#configurer-la-gestion-de-la-puissance)
|
||||
|
||||
Cette fonction vous permet de réguler la consommation électrique de vos radiateurs. Connue sous le nom de délestage, cette fonction vous permet de limiter la consommation électrique de votre appareil de chauffage si des conditions de surpuissance sont détectées.
|
||||
Vous aurez besoin d'un **capteur de la puissance totale instantanée consommée** de votre logement ainsi que d'un **capteur donnant la puissance maximale autorisée**.
|
||||
|
||||
Le comportement de cette fonction est basique :
|
||||
1. lorsque le _VTherm_ va allumer un équipement,
|
||||
2. il compare la dernière valeur connue du capteur de puissance consommée avec la dernière valeur de la puissance maximale autorisée. Si il reste une marge supérieure égale à la puissance déclarée des équipements du _VTherm_ alors le VTherm et ses équipements seront allumés. Sinon ils resteront éteints jusqu'au prochain cycle.
|
||||
|
||||
ATTENTION: ce fonctionnement très basique **n'est pas une fonction de sécurité** mais plus une fonction permettant une optimisation de la consommation au prix d'une dégradation du chauffage. Des dépassements sont possibles selon la fréquence de remontée de vos capteurs de consommation, la puissance réellement utilisée par votre équipements. Vous devez donc toujours garder une marge de sécurité.
|
||||
|
||||
Cas d'usage type:
|
||||
1. vous avez un compteur électrique limité à 11 kW,
|
||||
2. vous chargez de temps en temps un véhicle électrique à 5 kW,
|
||||
3. il reste donc 6 kW pour tout le reste y compris le chauffage,
|
||||
4. vous avez 1 kW d'autres équipements en cours,
|
||||
5. vous avez déclaré un capteur (`input_number`) de puissance max autorisée à 9 kW (= 11 kW - la réserve pour les autres équipements - marge)
|
||||
|
||||
Si la vehicle est en charge, la puissance totale consommé est de 6 kW (5+1) et un _VTherm_ ne s'allumera que si sa puissance déclarée est de 3 kW max (9 kW - 6 kW).
|
||||
Si la vehicle est en charge et qu'un autre _VTherm_ de 2 kW est allumé, la puissance totale consommé est de 8 kW (5+1+2) et un _VTherm_ ne s'allumera que si sa puissance déclarée est de 1 kW max (9 kW - 8 kW). Sinon il passe son tour (cycle).
|
||||
|
||||
Si le vehicle n'est pas en charge, la puissance totale consommé est de 1 kW, un _VTherm_ ne s'allumera que si sa puissance déclarée est de 8 kW max (9 kW - 1 kW).
|
||||
|
||||
## Configurer la gestion de la puissance
|
||||
|
||||
Si vous avez choisi la fonctionnalité `Avec détection de la puissance`, vous la configurez de la façon suivante :
|
||||

|
||||
|
||||
1. l'id d'entité du **capteur de puissance instantané consommé** de votre logement,
|
||||
2. l'id d'entité du **capteur de puissance maximale autorisée**,
|
||||
3. la température à appliquer si le délestage est appliqué.
|
||||
|
||||
Notez que toutes les valeurs de puissance doivent avoir les mêmes unités (kW ou W par exemple).
|
||||
Le fait d'avoir un **capteur de puissance maximale autorisée**, vous permet de modifier la puissance maximale au fil du temps à l'aide d'un planificateur ou d'une automatisation.
|
||||
|
||||
>  _*Notes*_
|
||||
> 1. En cas de délestage, le radiateur est réglé sur le préréglage nommé `power`. Il s'agit d'un préréglage caché, vous ne pouvez pas le sélectionner manuellement.
|
||||
> 2. Gardez toujours une marge, car la puissance max peut être brièvement dépassée en attendant le calcul du prochain cycle typiquement ou par des équipements non régulés.
|
||||
> 3. Si vous ne souhaitez pas utiliser cette fonctionnalité, décochez la dans le menu 'Fonctions'.
|
||||
> 4. Si une _VTherm_ controlez plusieurs équipements, la **consommation électrique de votre chauffage** renseigné doit correspondre à la somme des puissances.
|
||||
> 5. Si vous utilisez la carte Verstatile Thermostat UI (cf. [ici](additions.md#bien-mieux-avec-le-versatile-thermostat-ui-card)), le délestage est représenté comme suit : .
|
||||
24
documentation/fr/feature-presence.md
Normal file
@@ -0,0 +1,24 @@
|
||||
# Gestion de la présence / absence
|
||||
|
||||
- [Gestion de la présence / absence](#gestion-de-la-présence--absence)
|
||||
- [Configurer la présence (ou l'absence)](#configurer-la-présence-ou-labsence)
|
||||
|
||||
## Configurer la présence (ou l'absence)
|
||||
|
||||
Si cette fonction est sélectionnée, elle vous permet de modifier dynamiquement la température des préréglages du thermostat lorsqu'une présence (ou absence) est détectée. Pour cela, vous devez configurer la température qui sera utilisée pour chaque préréglage lorsque la présence est désactivée. Lorsque le capteur de présence s'éteint, ces températures seront utilisées. Lorsqu'il se rallume, la température "normale" configurée pour le préréglage est utilisée. Voir [gestion des préréglages](feature-presets.md).
|
||||
|
||||
Pour configurer la présence remplissez ce formulaire :
|
||||
|
||||

|
||||
|
||||
Pour cela, vous devez simplement configurer un **capteur d'occupation** dont l'état doit être 'on' ou 'home' si quelqu'un est présent ou 'off' ou 'not_home' sinon,
|
||||
|
||||
Les températures sont configurées dans les entités de l'équipement correspondant à votre _VTherm_ (Paramètres/Intégration/Versatile Thermostat/le vtherm)
|
||||
|
||||
ATTENTION : les groupes de personnes ne fonctionnent pas en tant que capteur de présence. Ils ne sont pas reconnus comme un capteur de présence. Vous devez utiliser, un template comme décrit ici [Utilisation d'un groupe de personnes comme capteur de présence](troubleshooting.md#utilisation-dun-groupe-de-personnes-comme-capteur-de-présence).
|
||||
|
||||
>  _*Notes*_
|
||||
> 1. le changement de température est immédiat et se répercute sur le volet avant. Le calcul prendra en compte la nouvelle température cible au prochain calcul du cycle,
|
||||
> 2. vous pouvez utiliser le capteur direct person.xxxx ou un groupe de capteurs de Home Assistant. Le capteur de présence gère les états ``on`` ou ``home`` comme présents et les états ``off`` ou ``not_home`` comme absents.
|
||||
> 3. pour pré-chauffer votre logement alors que tout le monde est absent, vous pouvez ajouter une entité de type `input_boolean` dans votre groupe de personne. Si vous passez cet `input_boolean` sur 'On' alors le capteur de présence sera forcé sur 'On' et les presets avec présence seront utilisés. Vous pouvez aussi positionner cet `input_boolean` sur 'On' via une automatisation par exemple lorsque vous quittez une zone pour lancer le préchauffage de votre logement.
|
||||
|
||||
30
documentation/fr/feature-presets.md
Normal file
@@ -0,0 +1,30 @@
|
||||
# Les pre-réglages (preset)
|
||||
|
||||
- [Les pre-réglages (preset)](#les-pre-réglages-preset)
|
||||
- [Configurer les températures préréglées](#configurer-les-températures-préréglées)
|
||||
|
||||
|
||||
## Configurer les températures préréglées
|
||||
|
||||
Le mode préréglé (preset) vous permet de préconfigurer la température ciblée. Utilisé en conjonction avec Scheduler (voir [scheduler](additions##encore-mieux-avec-le-composant-scheduler-)) vous aurez un moyen puissant et simple d'optimiser la température par rapport à la consommation électrique de votre maison. Les préréglages gérés sont les suivants :
|
||||
- **Eco** : l'appareil est en mode d'économie d'énergie
|
||||
- **Confort** : l'appareil est en mode confort
|
||||
- **Boost** : l'appareil tourne toutes les vannes à fond
|
||||
|
||||
Si le mode AC est utilisé, vous pourrez aussi configurer les températures lorsque l'équipement en mode climatisation.
|
||||
|
||||
**Aucun** est toujours ajouté dans la liste des modes, car c'est un moyen de ne pas utiliser les preset mais une **température manuelle** à la place.
|
||||
|
||||
Les pré-réglages se font directement depuis les entités du _VTherm_ ou de la configuration centrale si vous utilisez la configuration centrale. A la création du _VTherm_, vous aurez différentes entités qui vont vous permettre de fixer les températures de chaque preset :
|
||||
|
||||
.
|
||||
|
||||
La liste des entités varient en fonction de vos choix de fonction :
|
||||
1. si la fonction 'détection de présence' est activée vous aurez les presets en version absence préfixé par _abs_,
|
||||
2. si vous avez choisi l'option _AC_, vous aurez en plus les presets en version 'climatisation' préfixé par _clim_
|
||||
|
||||
>  _*Notes*_
|
||||
> 1. Lorsque vous modifiez manuellement la température cible, le préréglage passe sur Aucun (pas de préréglage),
|
||||
> 2. Le préréglage standard ``Away`` est un préréglage caché qui n'est pas directement sélectionnable. Versatile Thermostat utilise la gestion de présence ou la gestion de mouvement pour régler automatiquement et dynamiquement la température cible en fonction d'une présence dans le logement ou d'une activité dans la pièce. Voir [gestion de la présence](feature-presence.md).
|
||||
> 3. Si vous utilisez la gestion du délestage, vous verrez un préréglage caché nommé ``power``. Le préréglage de l'élément chauffant est réglé sur « puissance » lorsque des conditions de surpuissance sont rencontrées et que le délestage est actif pour cet élément chauffant. Voir [gestion de l'alimentation](feature-power.md).
|
||||
> 4. si vous utilisez la configuration avancée, vous verrez le préréglage défini sur ``sécurité`` si la température n'a pas pu être récupérée après un certain délai. Voir [Mise en sécurité](feature-advanced.md#la-mise-en-sécurité)
|
||||
66
documentation/fr/feature-window.md
Normal file
@@ -0,0 +1,66 @@
|
||||
# La détection d'ouverture - portes/fenêtres
|
||||
|
||||
- [La détection d'ouverture - portes/fenêtres](#la-détection-douverture---portesfenêtres)
|
||||
- [Le mode capteur](#le-mode-capteur)
|
||||
- [Le mode auto](#le-mode-auto)
|
||||
|
||||
Vous devez avoir choisi la fonctionnalité ```Avec détection des ouvertures``` dans la première page pour arriver sur cette page.
|
||||
La détection des ouvertures peut se faire de 2 manières:
|
||||
1. soit avec un capteur placé sur l'ouverture (mode capteur),
|
||||
2. soit en détectant une chute brutale de température (mode auto)
|
||||
|
||||
La configuration de la détection d'ouverture est la suivante :
|
||||
|
||||

|
||||
|
||||
## Le mode capteur
|
||||
Pour passer en mode capteur, vous devez donner une entité de type `binary_sensor` ou `input_boolean`.
|
||||
Dans ce mode, vous devez renseigner les informations suivantes:
|
||||
|
||||

|
||||
|
||||
1. un **délai en secondes** avant tout changement. Cela permet d'ouvrir rapidement une fenêtre sans arrêter le chauffage,
|
||||
2. l'action a réaliser lorsque l'ouverture est détectée ouverte. Les actions possibles sont :
|
||||
1. _Eteindre_ : le VTherm sera étient,
|
||||
2. _Ventilateur seul_ : le chauffage ou refroidissement sera coupé mais l'équipement continuera à ventiler (pour les équipements compatibles),
|
||||
3. _Hors gel_ : la température du preset 'Hors Gel' sera alors sélectionné sur le _VTherm_ sans changement du preset courant (cf. notes ci-dessous),
|
||||
4. _Eco_ : la température du preset _Eco_ sera appliquée sur le _VTherm_ sans changement du preset courant (cf. notes ci-dessous).
|
||||
|
||||
Lorsque le détecteur passe à ouvert :
|
||||
1. _VTherm_ attend le délai indiqué,
|
||||
2. si l'ouverture est toujours ouverte au bout du délai, l'état du _VTherm_ est mémorisée (mode Chauffe / Froid / ..., preset courant, temperature de consigne courante) et l'action est réalisée
|
||||
|
||||
Pareil, lorsque le détecteur passe à fermé :
|
||||
1. _VTherm_ attend le délai indiqué,
|
||||
2. si l'ouverture est toujours fermée au bout du délai, l'état avant ouverture mémorisé est restauré.
|
||||
|
||||
## Le mode auto
|
||||
En mode auto, la configuration est la suivante:
|
||||

|
||||
|
||||
1. un **délai en secondes** avant tout changement. Cela permet d'ouvrir rapidement une fenêtre sans arrêter le chauffage,
|
||||
2. un seuil de détection en degré par heure. Lorsque la température chute au delà de ce seuil, le thermostat s'éteindra. Plus cette valeur est faible et plus la détection sera rapide (en contre-partie d'un risque de faux positif),
|
||||
3. un seuil de fin de détection en degré par heure. Lorsque la chute de température repassera au-dessus cette valeur, le thermostat se remettra dans le mode précédent (mode et preset),
|
||||
4. une durée maximale de détection. Au delà de cette durée, le thermostat se remettra dans son mode et preset précédent même si la température continue de chuter
|
||||
5. l'action a réaliser lorsque l'ouverture est détectée ouverte. Les actions sont les mêmes qu'en mode capteur décrit ci-dessus.
|
||||
|
||||
Pour régler les seuils il est conseillé de commencer avec les valeurs de référence et d'ajuster les seuils de détection. Quelques essais m'ont donné les valeurs suivantes (pour un bureau):
|
||||
- seuil de détection : 3 °C/heure
|
||||
- seuil de non détection: 0 °C/heure
|
||||
- durée max : 30 min.
|
||||
|
||||
Un nouveau capteur nommé "slope" a été ajouté pour tous les thermostats. Il donne la pente de la courbe de température en °C/heure (ou °K/heure). Cette pente est lissée et filtrée pour éviter les valeurs abérrantes des thermomètres qui viendraient pertuber la mesure.
|
||||
|
||||

|
||||
|
||||
Pour bien régler il est conseillé d'affocher sur un même graphique historique la courbe de température et la pente de la courbe (le "slope") :
|
||||
|
||||

|
||||
|
||||
>  _*Notes*_
|
||||
> 1. Si vous souhaitez utiliser **plusieurs capteurs de porte/fenêtre** pour automatiser votre thermostat, créez simplement un groupe avec le comportement habituel (https://www.home-assistant.io/integrations/binary_sensor.group/)
|
||||
> 2. Si vous n'avez pas de capteur de fenêtre/porte dans votre chambre, laissez simplement l'identifiant de l'entité du capteur vide,
|
||||
> 3. **Un seul mode est permis**. On ne peut pas configurer un thermostat avec un capteur et une détection automatique. Les 2 modes risquant de se contredire, il n'est pas possible d'avoir les 2 modes en même temps,
|
||||
> 4. Il est déconseillé d'utiliser le mode automatique pour un équipement soumis à des variations de température fréquentes et normales (couloirs, zones ouvertes, ...)
|
||||
> 5. Pour éviter d'interférer avec votre réglage de preset courant, Les actions _Hors gel_ et _Eco_ change la température cible sans changer le preset. Donc, vous pouvez constater un écart entre le preset sélectionné et la consigne.
|
||||
> 6. Si vous utilisez la carte Verstatile Thermostat UI (cf. [ici](additions.md#bien-mieux-avec-le-versatile-thermostat-ui-card)), une détection d'ouverture est représenté comme suit : .
|
||||
BIN
documentation/fr/images/activity-preset-icon.png
Normal file
|
After Width: | Height: | Size: 1.5 KiB |
BIN
documentation/fr/images/add-an-integration.png
Normal file
|
After Width: | Height: | Size: 9.1 KiB |
BIN
documentation/fr/images/auto-start-stop-icon.png
Normal file
|
After Width: | Height: | Size: 1.3 KiB |
BIN
documentation/fr/images/central-mode.png
Normal file
|
After Width: | Height: | Size: 16 KiB |
BIN
documentation/fr/images/colored-thermostat-sensors.png
Normal file
|
After Width: | Height: | Size: 29 KiB |
BIN
documentation/fr/images/config-advanced.png
Normal file
|
After Width: | Height: | Size: 34 KiB |
BIN
documentation/fr/images/config-auto-start-stop.png
Normal file
|
After Width: | Height: | Size: 9.2 KiB |
BIN
documentation/fr/images/config-central-boiler-1.png
Normal file
|
After Width: | Height: | Size: 26 KiB |
BIN
documentation/fr/images/config-central-boiler-2.png
Normal file
|
After Width: | Height: | Size: 85 KiB |
BIN
documentation/fr/images/config-complete.png
Normal file
|
After Width: | Height: | Size: 3.1 KiB |
BIN
documentation/fr/images/config-features-old.png
Normal file
|
After Width: | Height: | Size: 23 KiB |
BIN
documentation/fr/images/config-features.png
Normal file
|
After Width: | Height: | Size: 23 KiB |
BIN
documentation/fr/images/config-linked-entity.png
Normal file
|
After Width: | Height: | Size: 36 KiB |
BIN
documentation/fr/images/config-linked-entity2.png
Normal file
|
After Width: | Height: | Size: 50 KiB |
BIN
documentation/fr/images/config-linked-entity3.png
Normal file
|
After Width: | Height: | Size: 26 KiB |
BIN
documentation/fr/images/config-main-old.png
Normal file
|
After Width: | Height: | Size: 45 KiB |
BIN
documentation/fr/images/config-main.png
Normal file
|
After Width: | Height: | Size: 54 KiB |
BIN
documentation/fr/images/config-main0.png
Normal file
|
After Width: | Height: | Size: 28 KiB |
BIN
documentation/fr/images/config-menu-all-options.png
Normal file
|
After Width: | Height: | Size: 40 KiB |
BIN
documentation/fr/images/config-menu.png
Normal file
|
After Width: | Height: | Size: 28 KiB |
BIN
documentation/fr/images/config-motion.png
Normal file
|
After Width: | Height: | Size: 42 KiB |
BIN
documentation/fr/images/config-not-complete.png
Normal file
|
After Width: | Height: | Size: 3.6 KiB |
BIN
documentation/fr/images/config-power.png
Normal file
|
After Width: | Height: | Size: 42 KiB |
BIN
documentation/fr/images/config-presence.png
Normal file
|
After Width: | Height: | Size: 21 KiB |
BIN
documentation/fr/images/config-preset-temp.png
Normal file
|
After Width: | Height: | Size: 38 KiB |
BIN
documentation/fr/images/config-self-regulation-valve-1.png
Normal file
|
After Width: | Height: | Size: 4.5 KiB |
BIN
documentation/fr/images/config-self-regulation-valve-2.png
Normal file
|
After Width: | Height: | Size: 71 KiB |
BIN
documentation/fr/images/config-terminate.png
Normal file
|
After Width: | Height: | Size: 19 KiB |
BIN
documentation/fr/images/config-tpi.png
Normal file
|
After Width: | Height: | Size: 14 KiB |
BIN
documentation/fr/images/config-use-internal-temp.png
Normal file
|
After Width: | Height: | Size: 5.0 KiB |
BIN
documentation/fr/images/config-window-auto.png
Normal file
|
After Width: | Height: | Size: 52 KiB |
BIN
documentation/fr/images/config-window-main.png
Normal file
|
After Width: | Height: | Size: 24 KiB |
BIN
documentation/fr/images/config-window-sensor.png
Normal file
|
After Width: | Height: | Size: 25 KiB |
BIN
documentation/fr/images/custom-css-thermostat.png
Normal file
|
After Width: | Height: | Size: 25 KiB |
BIN
documentation/fr/images/dev-tools-climate.png
Normal file
|
After Width: | Height: | Size: 104 KiB |
BIN
documentation/fr/images/dev-tools-turnon-boiler-1.png
Normal file
|
After Width: | Height: | Size: 47 KiB |
BIN
documentation/fr/images/dev-tools-turnon-boiler-2.png
Normal file
|
After Width: | Height: | Size: 31 KiB |
BIN
documentation/fr/images/en/config-linked-entity.png
Normal file
|
After Width: | Height: | Size: 50 KiB |
BIN
documentation/fr/images/enable-auto-start-stop-entity.png
Normal file
|
After Width: | Height: | Size: 4.1 KiB |
BIN
documentation/fr/images/entitites-central-boiler.png
Normal file
|
After Width: | Height: | Size: 24 KiB |
BIN
documentation/fr/images/icon.png
Normal file
|
After Width: | Height: | Size: 58 KiB |
BIN
documentation/fr/images/icon@2x.png
Normal file
|
After Width: | Height: | Size: 217 KiB |
BIN
documentation/fr/images/logos.xcf
Normal file
BIN
documentation/fr/images/motion-detection-icon.png
Normal file
|
After Width: | Height: | Size: 1.9 KiB |
BIN
documentation/fr/images/multi-switch-activation.png
Normal file
|
After Width: | Height: | Size: 22 KiB |
BIN
documentation/fr/images/my-tuning.png
Normal file
|
After Width: | Height: | Size: 49 KiB |
BIN
documentation/fr/images/new-icon.png
Normal file
|
After Width: | Height: | Size: 6.7 KiB |
BIN
documentation/fr/images/over-climate-schema.png
Normal file
|
After Width: | Height: | Size: 100 KiB |
BIN
documentation/fr/images/over-switch-schema.png
Normal file
|
After Width: | Height: | Size: 128 KiB |
BIN
documentation/fr/images/over-valve-schema.png
Normal file
|
After Width: | Height: | Size: 75 KiB |
BIN
documentation/fr/images/plotly-curves.png
Normal file
|
After Width: | Height: | Size: 50 KiB |
BIN
documentation/fr/images/power-exceeded-icon.png
Normal file
|
After Width: | Height: | Size: 1.6 KiB |
BIN
documentation/fr/images/results-1.png
Normal file
|
After Width: | Height: | Size: 69 KiB |
BIN
documentation/fr/images/results-2.png
Normal file
|
After Width: | Height: | Size: 3.3 KiB |
BIN
documentation/fr/images/results-3.png
Normal file
|
After Width: | Height: | Size: 11 KiB |
BIN
documentation/fr/images/results-4.png
Normal file
|
After Width: | Height: | Size: 122 KiB |
BIN
documentation/fr/images/results-fine-tuned.png
Normal file
|
After Width: | Height: | Size: 129 KiB |
BIN
documentation/fr/images/results-over-climate-1.png
Normal file
|
After Width: | Height: | Size: 62 KiB |
BIN
documentation/fr/images/results-over-climate-2.png
Normal file
|
After Width: | Height: | Size: 28 KiB |
BIN
documentation/fr/images/safety-mode-icon.png
Normal file
|
After Width: | Height: | Size: 27 KiB |
BIN
documentation/fr/images/security-mode-symptome1.png
Normal file
|
After Width: | Height: | Size: 58 KiB |
BIN
documentation/fr/images/security-mode-symptome2.png
Normal file
|
After Width: | Height: | Size: 85 KiB |
BIN
documentation/fr/images/simple-thermostat.png
Normal file
|
After Width: | Height: | Size: 30 KiB |
BIN
documentation/fr/images/temp-entities-1.png
Normal file
|
After Width: | Height: | Size: 24 KiB |