309 Commits

Author SHA1 Message Date
Jean-Marc Collin
3529607948 Issue #645 add sonoff trvzb (#651)
* With Sonoff configuration ok

* Fix configuration

* Next (not finished)

* With 1rst implementation of VTherm TRVZB and underlying

* Work in simuated environment

* Fix Testus

* Release

* Fix release name

* Add #602 - implement a max_on_percent setting

* Calculate offset_calibration as room_temp - local_temp
Fix hvac_action calculation

* Fix hvac_action
Fix offset_calibration=room_temp - (local_temp - current_offset)

* Fix underlying target is not updated

* Issue #655 - combine motion and presence

* Fix Valve testus. Improve sending the open percent to valve

* Update custom_components/versatile_thermostat/translations/en.json

Co-authored-by: Alexander Dransfield <2844540+alexdrans@users.noreply.github.com>

* Indus step1

* Step 2 - renaming. All tests ok

* Step 2: manual tests ok

* First unit test ok

* Test multi ok

* All tests ok. Add a multi test for climate with valve regulation

* With testu for config_flow ok

* Documentation (not finished)

* Fix #661 - central boiler doesn't starts with Sonoff TRVZB

* Remove // testing

* Fix exception when there is no offset at all

* Fix class attributes and instance attributes mixing

* Documentation 2

* Documentation 3

* Documentation ++

* documentation

* Try to fix the central boiler calculation

* Fix #669

* Documentation ++

* Documentation ok for FR

* Readme FR|EN

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
Co-authored-by: Alexander Dransfield <2844540+alexdrans@users.noreply.github.com>
2024-12-07 19:05:55 +01:00
ms5
289ccc7bb7 Implementing max_on_percent setting (#632)
* implementing max_on_percent setting

* remove % sign from log message

* README updated: created new export-mode section, moved self-regulation expert settings to new section, added new section about on-time clamping
2024-11-17 18:28:24 +01:00
Gernot Messow
4f8e45dda6 Just ignore illegal target temp, do not throw away all data (#635)
Co-authored-by: Gernot Messow <gmessow@insys-locks.de>
2024-11-14 21:54:15 +01:00
Jean-Marc Collin
b46a24f834 Issue #628 add follow underlying temp change entity (#630)
* First commit (no test)

* With tests ok

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-11-13 19:14:03 +01:00
Jean-Marc Collin
ba69319198 Issue #619 - manual hvac_off should be prioritized over window and auto-start/stop hvac_off (#622)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-11-10 10:17:53 +01:00
Jean-Marc Collin
f9df925181 Issue #615 - VTherm switch to manual on its own (#618)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-11-09 18:44:13 +01:00
Jean-Marc Collin
2d72efe447 Issue 600 energy can be negative after configuration (#614)
* Add logs to diagnose the case

* Issue #552 (#608)

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>

* Fix typo (#607)

* - Force writing state when entity is removed
- Fix bug with issue #552 on CONF_USE_CENTRAL_BOILER_FEATURE which should be proposed on a central configuration
- Improve reload of entity to avoid reloading all VTherm. Only the reconfigured one will be reloaded

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
Co-authored-by: Ludovic BOUÉ <lboue@users.noreply.github.com>
2024-11-07 21:57:08 +01:00
Jean-Marc Collin
06dc537767 Issue #552 (#608)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-11-05 22:39:26 +01:00
Joeri Colman
2d79d961dc Update en.json (#604)
fixed typo
2024-11-05 10:40:49 +01:00
Jean-Marc Collin
a0e548ef71 Release 2024-11-03 22:16:15 +00:00
hilburn
e6c330fc9d Underlying config changes (#590)
* Changes config_flow to allow dynamic length list of underlying entities
Updates previously defined 4x entries to new config style
Changes to thermostat_X to load underlying entities from list
Changes to thermostat X to display underlying entities as a list - COULD BREAK EXISTING TEMPLATES

* Modifies tests to use the new list format

* Added English translation for UI

* Removed all references to individual entities in strings/en.json

* Fix merge mistake

---------

Co-authored-by: Jean-Marc Collin <jm.collin.78@gmail.com>
2024-11-03 22:52:19 +01:00
Jean-Marc Collin
968e8286ea Add some infos 2024-11-03 21:50:42 +00:00
hilburn
0f60c070ab Preset display tweaks (#599)
* Addded Frost Preset to translations
Added Icons for Shedding, Safety, Manual and Frost Presets

* Fixed French Translation
2024-11-03 11:50:37 +01:00
Jean-Marc Collin
b4860c2b8d Issue 585 add auto start/stop feature (#594)
* Migrate to HA 2024.10.4

* Auto start/stop alog and testu + ConfigFlow

* With config flow ok

* Change algo

* All is fine

* Add change_preset test

* + comment

* FIX too much start/stop

* Change algo to take slop into account

* Allow calculation even if slope is None

* With enable + tests + hysteresis in calculation

* Add hvac_off_reason and test with window interaction

* Fix some tests

* Restore saved_state

* Release

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-11-01 18:54:22 +01:00
Gernot Messow
60bd522a97 Filter out-of-range target temperature sent from underlying climate devices (#581)
* Filter out-of-range temperature from underlying climate

* Fixed broken test case, added new test case for range filtering
2024-10-27 09:21:08 +01:00
Jean-Marc Collin
f6fb7487d5 Issue #467 - Always apply offset compensation (#567)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-10-16 19:33:55 +02:00
Jean-Marc Collin
0f585be0c9 issue #556 - enhance motion detection feature (2) 2024-10-16 05:08:57 +00:00
Jean-Marc Collin
492c95aff5 FIX issue #556 - enhance motion detection feature (#560)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-10-14 20:14:51 +02:00
Jean-Marc Collin
a530051bbd FIX #518 TypeError: unsupported operand type(s) for -: 'int' and 'NoneType' (#559)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-10-14 19:29:34 +02:00
Jean-Marc Collin
2ea5cf471b Cleaning 2024-10-14 16:58:18 +00:00
Jean-Marc Collin
f29b2f9b81 with local tests ok. 2024-10-14 07:01:27 +00:00
Jean-Marc Collin
d112273c58 Fix preset temp is sommetimes lost on over_climate 2024-10-14 04:43:19 +00:00
Jean-Marc Collin
73a9ca4e53 Issue #478 vtherm doesn't follow underlying (#548)
* Dispatch test_bugs into each own VTherm type tests

* Local tests ok

* With testus ok.

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-10-13 11:30:04 +02:00
Jean-Marc Collin
1334bdbd8f FIX #465 and make this coherent with Windows open/close (#545)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-10-12 17:32:05 +02:00
Jean-Marc Collin
646ef47f6f Fix issue #485 (#544)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-10-12 12:50:12 +02:00
Jean-Marc Collin
c344c43185 FIX #518 (#543)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-10-12 11:02:24 +02:00
Jean-Marc Collin
062f8a617d Fix #533 (#542)
Clean some pylint hints
Avoid 2 times open percentage send at startup

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-10-12 10:46:13 +02:00
Jean-Marc Collin
70f91f3cbe Issue #524 switch from cool to heat don't change the target temp (#529)
* Preparation tests ok

* Fixed

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-10-08 17:06:16 +02:00
Jean-Marc Collin
668053b352 Fix unit_test 2024-10-07 05:22:57 +00:00
Jean-Marc Collin
6ff9ff1ee5 Fix variables in error log 2024-10-07 04:52:33 +00:00
Jean-Marc Collin
3f95ed74f4 FIX TypeError: '>' not supported between instances of 'float' and 'NoneType' error message 2024-10-06 09:04:47 +00:00
Jean-Marc Collin
6e42904ddf Issue #518 - Fix ThermostatOverClimate object has no attribute __attr_preset_modes 2024-10-06 08:58:58 +00:00
Jean-Marc Collin
4c1fc396fb Issue #500 - check feature is use central config is checked (#513)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-09-29 11:34:39 +02:00
Jean-Marc Collin
d6ec7a86be issue #506 - Add some check to verify tpi algorithm parameters are correctly set. (#512)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-09-29 09:54:39 +02:00
Jean-Marc Collin
a3f8715fe5 HA 2024.9.3 and issue 508 (#510)
* HA 2024.9.3 and issue 508

* Fix strings trailing spaces

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-09-28 19:36:46 +02:00
Jean-Marc Collin
c4b03f8c1e Update manifest.json 2024-07-07 16:49:22 +02:00
Paulo Ferreira de Castro
ac206a949f Fix Home Assistant deprecation warnings (EventType, helpers.service) (#484)
* Type hints: Replace deprecated helpers.typing.EventType with core.Event

* Replace deprecated use of hass.helpers.service.async_register_admin_service
2024-07-07 16:47:30 +02:00
Jean-Marc Collin
4bccb746b8 Release 6.2.8 2024-07-02 05:18:29 +00:00
Jean-Marc Collin
e999705286 Issue 474 - TPI in AC mode is wrong 2024-07-02 05:17:14 +00:00
Jean-Marc Collin
b4873bfd27 FIX issue_479 (#480)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-07-02 07:04:47 +02:00
Jean-Marc Collin
b00dc09c80 Update manifest.json 2024-06-30 09:05:14 +02:00
Paulo Ferreira de Castro
864e904e21 Reduce keep-alive warning logs when the controlled entity becomes unavailable (#476) 2024-06-28 09:53:40 +02:00
cddu33
0ee4fe355d issue with ac and mouvement detection (#471)
* Update base_thermostat.py

issue with ac and mouvement detection

* issue ac with detection mouvement

modif class find_preset_temps for preset activity
2024-06-17 10:18:03 +02:00
Maxwell Gonsalves
53dce224cd Change VTherm temperature unit to HA's preferred unit. (#461)
* Change VTherm temperature unit to HA's preferred unit.

* fix pytest issue

* update current_temperature, explicitly convert temps (fixes pytest error)
2024-06-10 18:46:45 +02:00
jkreiss-coexya
549423b313 Enhance temperature regulation when working with internal device temperature (#453)
* [feature/autoregulation-send-for-underlyingtemp] Do not forget regulation send when using underlying device temperature for offset

* [feature/autoregulation-send-for-underlyingtemp] Add unit test for dtemp = 0

* [feature/autoregulation-send-for-underlyingtemp] Test with dtemp lower than 0.5

* [feature/autoregulation-send-for-underlyingtemp] Comments
2024-05-13 08:27:52 +02:00
Matt Bush
6bd1b1137e [Draft] Use user's preferred temperature unit instead of hardcoding celsius (#460)
* Use user's preferred temperature unit instead of hardcoding celsius

* Fix warnings about using is instead of == in tests
2024-05-13 07:47:04 +02:00
misa1515
e1ff23fb30 Update sk.json (#454) 2024-04-29 07:15:26 +02:00
Jean-Marc Collin
7b657ffabf Issue 444 ha 2024.04.3 (#452)
* HA 2024.4.3 and release

* [#444] - fix initial temp values with standalone presets

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-04-23 07:58:22 +02:00
Jean-Marc Collin
acd22d1fc4 HA 2024.4.3 and release (#447)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-04-16 08:54:59 +02:00
Jean-Marc Collin
d6f33d5796 [#438] - manage total_energy none until restored or calculated (#446)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-04-16 07:14:38 +02:00