Fix preset temp is sommetimes lost on over_climate
This commit is contained in:
@@ -692,6 +692,12 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
else None
|
||||
)
|
||||
|
||||
under_temp_diff = (
|
||||
(new_target_temp - under.last_sent_temperature) if new_target_temp else 0
|
||||
)
|
||||
if -1 < under_temp_diff < 1:
|
||||
under_temp_diff = 0
|
||||
|
||||
# Issue 99 - some AC turn hvac_mode=cool and hvac_action=idle when sending a HVACMode_OFF command
|
||||
# Issue 114 - Remove this because hvac_mode is now managed by local _hvac_mode and use idle action as is
|
||||
# if self._hvac_mode == HVACMode.OFF and new_hvac_action == HVACAction.IDLE:
|
||||
@@ -702,7 +708,7 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
if (
|
||||
new_hvac_mode == self._hvac_mode
|
||||
and new_hvac_action == old_hvac_action
|
||||
and new_target_temp is None
|
||||
and under_temp_diff == 0
|
||||
and (new_fan_mode is None or new_fan_mode == self._attr_fan_mode)
|
||||
):
|
||||
_LOGGER.debug(
|
||||
@@ -834,11 +840,8 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
under.last_sent_temperature,
|
||||
new_target_temp,
|
||||
)
|
||||
if (
|
||||
# if the underlying have change its target temperature
|
||||
new_target_temp is not None
|
||||
and new_target_temp != under.last_sent_temperature
|
||||
):
|
||||
# if the underlying have change its target temperature
|
||||
if under_temp_diff != 0:
|
||||
_LOGGER.info(
|
||||
"%s - Target temp in underlying have change to %s (vs %s)",
|
||||
self,
|
||||
@@ -849,7 +852,7 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
changes = True
|
||||
else:
|
||||
_LOGGER.debug(
|
||||
"%s - Forget the eventual underlying temperature change because VTherm is regulated",
|
||||
"%s - Forget the eventual underlying temperature change there is no real change",
|
||||
self,
|
||||
)
|
||||
|
||||
|
||||
Reference in New Issue