Issue #99 - security mode toggling 100 times within 2 minutes

This commit is contained in:
Jean-Marc Collin
2023-08-27 18:06:43 +02:00
parent 6e8e72e343
commit b38fbd9d78

View File

@@ -1582,6 +1582,8 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
if not new_state:
return
new_hvac_mode = new_state.state
old_state = event.data.get("old_state")
old_hvac_action = (
old_state.attributes.get("hvac_action")
@@ -1594,16 +1596,21 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
else None
)
# Issue 99 - some AC turn hvac_mode=cool and hvac_action=idle when sending a HVACMode_OFF command
if self._hvac_mode == HVACMode.OFF and new_hvac_action == HVACAction.IDLE:
_LOGGER.debug("The underlying switch to idle instead of OFF. We will consider it as OFF")
new_hvac_mode = HVACMode.OFF
_LOGGER.info(
"%s - Underlying climate changed. Event.new_state is %s, current_hvac_mode=%s, new_hvac_action=%s, old_hvac_action=%s",
"%s - Underlying climate changed. Event.new_hvac_mode is %s, current_hvac_mode=%s, new_hvac_action=%s, old_hvac_action=%s",
self,
new_state,
new_hvac_mode,
self._hvac_mode,
new_hvac_action,
old_hvac_action,
)
if new_state.state in [
if new_hvac_mode in [
HVACMode.OFF,
HVACMode.HEAT,
HVACMode.COOL,
@@ -1613,7 +1620,7 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
HVACMode.FAN_ONLY,
None
]:
self._hvac_mode = new_state.state
self._hvac_mode = new_hvac_mode
# Interpretation of hvac
HVAC_ACTION_ON = [ # pylint: disable=invalid-name