FIX Service name Github error
This commit is contained in:
@@ -1,120 +1,121 @@
|
||||
reload:
|
||||
description: Reload all Versatile Thermostat entities.
|
||||
name: Reload
|
||||
description: Reload all Versatile Thermostat entities.
|
||||
|
||||
set_presence:
|
||||
name: Set presence
|
||||
description: Force the presence mode in thermostat
|
||||
target:
|
||||
entity:
|
||||
integration: versatile_thermostat
|
||||
fields:
|
||||
presence:
|
||||
name: Presence
|
||||
description: Presence setting
|
||||
required: true
|
||||
advanced: false
|
||||
example: "on"
|
||||
default: "on"
|
||||
selector:
|
||||
select:
|
||||
options:
|
||||
- "on"
|
||||
- "off"
|
||||
- "home"
|
||||
- "not_home"
|
||||
name: Set presence
|
||||
description: Force the presence mode in thermostat
|
||||
target:
|
||||
entity:
|
||||
integration: versatile_thermostat
|
||||
fields:
|
||||
presence:
|
||||
name: Presence
|
||||
description: Presence setting
|
||||
required: true
|
||||
advanced: false
|
||||
example: "on"
|
||||
default: "on"
|
||||
selector:
|
||||
select:
|
||||
options:
|
||||
- "on"
|
||||
- "off"
|
||||
- "home"
|
||||
- "not_home"
|
||||
|
||||
set_preset_temperature:
|
||||
name: Set temperature preset
|
||||
description: Change the target temperature of a preset
|
||||
target:
|
||||
entity:
|
||||
integration: versatile_thermostat
|
||||
fields:
|
||||
preset:
|
||||
name: Preset
|
||||
description: Preset name
|
||||
required: true
|
||||
advanced: false
|
||||
example: "comfort"
|
||||
selector:
|
||||
select:
|
||||
options:
|
||||
- "eco"
|
||||
- "comfort"
|
||||
- "boost"
|
||||
temperature:
|
||||
name: Temperature when present
|
||||
description: Target temperature for the preset when present
|
||||
required: false
|
||||
advanced: false
|
||||
example: "19.5"
|
||||
default: "17"
|
||||
selector:
|
||||
number:
|
||||
min: 7
|
||||
max: 35
|
||||
step: 0.1
|
||||
unit_of_measurement: °
|
||||
mode: slider
|
||||
temperature_away:
|
||||
name: Temperature when not present
|
||||
description: Target temperature for the preset when not present
|
||||
required: false
|
||||
advanced: false
|
||||
example: "17"
|
||||
default: "15"
|
||||
selector:
|
||||
number:
|
||||
min: 7
|
||||
max: 35
|
||||
step: 0.1
|
||||
unit_of_measurement: °
|
||||
mode: slider
|
||||
name: Set temperature preset
|
||||
description: Change the target temperature of a preset
|
||||
target:
|
||||
entity:
|
||||
integration: versatile_thermostat
|
||||
fields:
|
||||
preset:
|
||||
name: Preset
|
||||
description: Preset name
|
||||
required: true
|
||||
advanced: false
|
||||
example: "comfort"
|
||||
selector:
|
||||
select:
|
||||
options:
|
||||
- "eco"
|
||||
- "comfort"
|
||||
- "boost"
|
||||
temperature:
|
||||
name: Temperature when present
|
||||
description: Target temperature for the preset when present
|
||||
required: false
|
||||
advanced: false
|
||||
example: "19.5"
|
||||
default: "17"
|
||||
selector:
|
||||
number:
|
||||
min: 7
|
||||
max: 35
|
||||
step: 0.1
|
||||
unit_of_measurement: °
|
||||
mode: slider
|
||||
temperature_away:
|
||||
name: Temperature when not present
|
||||
description: Target temperature for the preset when not present
|
||||
required: false
|
||||
advanced: false
|
||||
example: "17"
|
||||
default: "15"
|
||||
selector:
|
||||
number:
|
||||
min: 7
|
||||
max: 35
|
||||
step: 0.1
|
||||
unit_of_measurement: °
|
||||
mode: slider
|
||||
|
||||
set_security:
|
||||
name: Set security
|
||||
description: Change the security parameters
|
||||
target:
|
||||
entity:
|
||||
integration: versatile_thermostat
|
||||
fields:
|
||||
delay_min:
|
||||
name: Delay in minutes
|
||||
description: Maximum allowed delay in minutes between two temperature mesures
|
||||
required: false
|
||||
advanced: false
|
||||
example: "30"
|
||||
selector:
|
||||
number:
|
||||
min: 0
|
||||
max: 9999
|
||||
unit_of_measurement: "min"
|
||||
mode: box
|
||||
min_on_percent:
|
||||
name: Minimal on_percent
|
||||
description: Minimal heating percent value for security preset activation
|
||||
required: false
|
||||
advanced: false
|
||||
example: "0.5"
|
||||
default: "0.5"
|
||||
selector:
|
||||
number:
|
||||
min: 0
|
||||
max: 1
|
||||
step: 0.05
|
||||
unit_of_measurement: "%"
|
||||
mode: slider
|
||||
default_on_percent:
|
||||
name: on_percent used in security mode
|
||||
description: The default heating percent value in security preset
|
||||
required: false
|
||||
advanced: false
|
||||
example: "0.1"
|
||||
default: "0.1"
|
||||
selector:
|
||||
number:
|
||||
min: 0
|
||||
max: 1
|
||||
step: 0.05
|
||||
unit_of_measurement: "%"
|
||||
mode: slider
|
||||
name: Set security
|
||||
description: Change the security parameters
|
||||
target:
|
||||
entity:
|
||||
integration: versatile_thermostat
|
||||
fields:
|
||||
delay_min:
|
||||
name: Delay in minutes
|
||||
description: Maximum allowed delay in minutes between two temperature mesures
|
||||
required: false
|
||||
advanced: false
|
||||
example: "30"
|
||||
selector:
|
||||
number:
|
||||
min: 0
|
||||
max: 9999
|
||||
unit_of_measurement: "min"
|
||||
mode: box
|
||||
min_on_percent:
|
||||
name: Minimal on_percent
|
||||
description: Minimal heating percent value for security preset activation
|
||||
required: false
|
||||
advanced: false
|
||||
example: "0.5"
|
||||
default: "0.5"
|
||||
selector:
|
||||
number:
|
||||
min: 0
|
||||
max: 1
|
||||
step: 0.05
|
||||
unit_of_measurement: "%"
|
||||
mode: slider
|
||||
default_on_percent:
|
||||
name: on_percent used in security mode
|
||||
description: The default heating percent value in security preset
|
||||
required: false
|
||||
advanced: false
|
||||
example: "0.1"
|
||||
default: "0.1"
|
||||
selector:
|
||||
number:
|
||||
min: 0
|
||||
max: 1
|
||||
step: 0.05
|
||||
unit_of_measurement: "%"
|
||||
mode: slider
|
||||
|
||||
Reference in New Issue
Block a user