Compare commits

..

2 Commits

Author SHA1 Message Date
Jean-Marc Collin
dc7739d53b Fix slope None 2024-12-08 17:18:02 +00:00
Jean-Marc Collin
729f263cc8 Fix 2024-12-08 17:05:39 +00:00
11 changed files with 21 additions and 154 deletions

View File

@@ -57,13 +57,10 @@ class AutoStartStopDetectionAlgorithm:
_accumulated_error: float = 0
_error_threshold: float | None = None
_last_calculation_date: datetime | None = None
_last_switch_date: datetime | None = None
def __init__(self, level: TYPE_AUTO_START_STOP_LEVELS, vtherm_name) -> None:
"""Initalize a new algorithm with the right constants"""
self._vtherm_name = vtherm_name
self._last_calculation_date = None
self._last_switch_date = None
self._init_level(level)
def _init_level(self, level: TYPE_AUTO_START_STOP_LEVELS):
@@ -146,26 +143,17 @@ class AutoStartStopDetectionAlgorithm:
temp_at_dt = current_temp + slope_min * self._dt
# Calculate the number of minute from last_switch
nb_minutes_since_last_switch = 999
if self._last_switch_date is not None:
nb_minutes_since_last_switch = (
now - self._last_switch_date
).total_seconds() / 60
# Check to turn-off
# When we hit the threshold, that mean we can turn off
if hvac_mode == HVACMode.HEAT:
if (
self._accumulated_error <= -self._error_threshold
and temp_at_dt >= target_temp + TEMP_HYSTERESIS
and nb_minutes_since_last_switch >= self._dt
):
_LOGGER.info(
"%s - We need to stop, there is no need for heating for a long time.",
self,
)
self._last_switch_date = now
return AUTO_START_STOP_ACTION_OFF
else:
_LOGGER.debug("%s - nothing to do, we are heating", self)
@@ -175,13 +163,11 @@ class AutoStartStopDetectionAlgorithm:
if (
self._accumulated_error >= self._error_threshold
and temp_at_dt <= target_temp - TEMP_HYSTERESIS
and nb_minutes_since_last_switch >= self._dt
):
_LOGGER.info(
"%s - We need to stop, there is no need for cooling for a long time.",
self,
)
self._last_switch_date = now
return AUTO_START_STOP_ACTION_OFF
else:
_LOGGER.debug(
@@ -192,15 +178,11 @@ class AutoStartStopDetectionAlgorithm:
# check to turn on
if hvac_mode == HVACMode.OFF and saved_hvac_mode == HVACMode.HEAT:
if (
temp_at_dt <= target_temp - TEMP_HYSTERESIS
and nb_minutes_since_last_switch >= self._dt
):
if temp_at_dt <= target_temp - TEMP_HYSTERESIS:
_LOGGER.info(
"%s - We need to start, because it will be time to heat",
self,
)
self._last_switch_date = now
return AUTO_START_STOP_ACTION_ON
else:
_LOGGER.debug(
@@ -210,15 +192,11 @@ class AutoStartStopDetectionAlgorithm:
return AUTO_START_STOP_ACTION_NOTHING
if hvac_mode == HVACMode.OFF and saved_hvac_mode == HVACMode.COOL:
if (
temp_at_dt >= target_temp + TEMP_HYSTERESIS
and nb_minutes_since_last_switch >= self._dt
):
if temp_at_dt >= target_temp + TEMP_HYSTERESIS:
_LOGGER.info(
"%s - We need to start, because it will be time to cool",
self,
)
self._last_switch_date = now
return AUTO_START_STOP_ACTION_ON
else:
_LOGGER.debug(
@@ -257,10 +235,5 @@ class AutoStartStopDetectionAlgorithm:
"""Get the level value"""
return self._level
@property
def last_switch_date(self) -> datetime | None:
"""Get the last of the last switch"""
return self._last_switch_date
def __str__(self) -> str:
return f"AutoStartStopDetectionAlgorithm-{self._vtherm_name}"

View File

@@ -82,10 +82,6 @@ T = TypeVar("T", bound=UnderlyingEntity)
class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
"""Representation of a base class for all Versatile Thermostat device."""
# breaking change with 2024.12 climate workaround
_attr_swing_horizontal_modes = []
_attr_swing_horizontal_mode = ""
_entity_component_unrecorded_attributes = (
ClimateEntity._entity_component_unrecorded_attributes.union(
frozenset(

View File

@@ -118,7 +118,7 @@ async def async_setup_entry(
SERVICE_SET_AUTO_REGULATION_MODE,
{
vol.Required("auto_regulation_mode"): vol.In(
["None", "Light", "Medium", "Strong", "Slow", "Expert"]
["None", "Light", "Medium", "Strong", "Slow"]
),
},
"service_set_auto_regulation_mode",

View File

@@ -14,6 +14,6 @@
"quality_scale": "silver",
"requirements": [],
"ssdp": [],
"version": "6.8.3",
"version": "6.8.0",
"zeroconf": []
}

View File

@@ -60,7 +60,6 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
"auto_start_stop_enable",
"auto_start_stop_accumulated_error",
"auto_start_stop_accumulated_error_threshold",
"auto_start_stop_last_switch_date",
"follow_underlying_temp_change",
}
)
@@ -183,8 +182,8 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
await super()._async_internal_set_temperature(temperature)
self._regulation_algo.set_target_temp(self.target_temperature)
# Is necessary cause control_heating method will not force the update.
await self._send_regulated_temperature(force=True)
# is done by control_heating method. No need to do it here
# await self._send_regulated_temperature(force=True)
async def _send_regulated_temperature(self, force=False):
"""Sends the regulated temperature to all underlying"""
@@ -556,10 +555,6 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
"auto_start_stop_accumulated_error_threshold"
] = self._auto_start_stop_algo.accumulated_error_threshold
self._attr_extra_state_attributes["auto_start_stop_last_switch_date"] = (
self._auto_start_stop_algo.last_switch_date
)
self._attr_extra_state_attributes["follow_underlying_temp_change"] = (
self._follow_underlying_temp_change
)
@@ -1119,6 +1114,15 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
return self._support_flags
# We keep the step configured for the VTherm and not the step of the underlying
# @property
# def target_temperature_step(self) -> float | None:
# """Return the supported step of target temperature."""
# if self.underlying_entity(0):
# return self.underlying_entity(0).target_temperature_step
#
# return None
@property
def target_temperature_high(self) -> float | None:
"""Return the highbound target temperature we try to reach.

View File

@@ -218,7 +218,7 @@
}
},
"valve_regulation": {
"title": "Auto-régulation par vanne",
"title": "Auto-régulation par vanne - {name}",
"description": "Configuration de l'auto-régulation par controle direct de la vanne",
"data": {
"offset_calibration_entity_ids": "Entités de 'calibrage du décalage''",
@@ -257,7 +257,7 @@
}
},
"menu": {
"title": "Menu",
"title": "Menu - {name}",
"description": "Paramétrez votre thermostat. Vous pourrez finaliser la configuration quand tous les paramètres auront été saisis.",
"menu_options": {
"main": "Principaux Attributs",

View File

@@ -3,5 +3,5 @@
"content_in_root": false,
"render_readme": true,
"hide_default_branch": false,
"homeassistant": "2024.12.3"
"homeassistant": "2024.10.4"
}

View File

@@ -1 +1 @@
homeassistant==2024.12.3
homeassistant==2024.10.4

View File

@@ -309,7 +309,7 @@ async def test_over_climate_regulation_limitations(
assert entity.hvac_action == HVACAction.HEATING
# the regulated temperature will not change because when we set temp manually it is forced
assert entity.regulated_target_temp == 19.5
assert entity.regulated_target_temp == 17 # 19.5
# 2. set manual target temp (at now - 18) -> the regulation should be taken into account
event_timestamp = now - timedelta(minutes=18)

View File

@@ -15,7 +15,6 @@ from custom_components.versatile_thermostat.auto_start_stop_algorithm import (
AutoStartStopDetectionAlgorithm,
AUTO_START_STOP_ACTION_NOTHING,
AUTO_START_STOP_ACTION_OFF,
AUTO_START_STOP_ACTION_ON,
)
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
@@ -45,7 +44,6 @@ async def test_auto_start_stop_algo_slow_heat_off(hass: HomeAssistant):
)
assert ret == AUTO_START_STOP_ACTION_NOTHING
assert algo.accumulated_error == -1
assert algo.last_switch_date is None
# 2. should not stop (accumulated_error too low)
now = now + timedelta(minutes=5)
@@ -59,7 +57,6 @@ async def test_auto_start_stop_algo_slow_heat_off(hass: HomeAssistant):
)
assert ret == AUTO_START_STOP_ACTION_NOTHING
assert algo.accumulated_error == -6
assert algo.last_switch_date is None
# 3. should not stop (accumulated_error too low)
now = now + timedelta(minutes=2)
@@ -73,7 +70,6 @@ async def test_auto_start_stop_algo_slow_heat_off(hass: HomeAssistant):
)
assert algo.accumulated_error == -8
assert ret == AUTO_START_STOP_ACTION_NOTHING
assert algo.last_switch_date is None
# 4 .No change on accumulated error because the new measure is too near the last one
now = now + timedelta(seconds=11)
@@ -87,7 +83,6 @@ async def test_auto_start_stop_algo_slow_heat_off(hass: HomeAssistant):
)
assert algo.accumulated_error == -8
assert ret == AUTO_START_STOP_ACTION_NOTHING
assert algo.last_switch_date is None
# 5. should stop now because accumulated_error is > ERROR_THRESHOLD for slow (10)
now = now + timedelta(minutes=4)
@@ -101,9 +96,6 @@ async def test_auto_start_stop_algo_slow_heat_off(hass: HomeAssistant):
)
assert algo.accumulated_error == -10
assert ret == AUTO_START_STOP_ACTION_OFF
assert algo.last_switch_date is not None
assert algo.last_switch_date == now
last_now = now
# 6. inverse the temperature (target > current) -> accumulated_error should be divided by 2
now = now + timedelta(minutes=2)
@@ -117,111 +109,14 @@ async def test_auto_start_stop_algo_slow_heat_off(hass: HomeAssistant):
)
assert algo.accumulated_error == -4 # -10/2 + 1
assert ret == AUTO_START_STOP_ACTION_NOTHING
assert algo.last_switch_date == last_now
# 7. change level to slow (no real change) -> error_accumulated should not reset to 0
algo.set_level(AUTO_START_STOP_LEVEL_SLOW)
assert algo.accumulated_error == -4
assert algo.last_switch_date == last_now
# 8. change level -> error_accumulated should reset to 0
algo.set_level(AUTO_START_STOP_LEVEL_FAST)
assert algo.accumulated_error == 0
assert algo.last_switch_date == last_now
async def test_auto_start_stop_too_fast_change(hass: HomeAssistant):
"""Testing directly the algorithm in Slow level"""
algo: AutoStartStopDetectionAlgorithm = AutoStartStopDetectionAlgorithm(
AUTO_START_STOP_LEVEL_SLOW, "testu"
)
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
assert algo._dt == 30
assert algo._vtherm_name == "testu"
#
# Testing with turn_on
#
# 1. should stop
algo._accumulated_error = -100
ret = algo.calculate_action(
hvac_mode=HVACMode.HEAT,
saved_hvac_mode=HVACMode.OFF,
target_temp=10,
current_temp=21,
slope_min=0.5,
now=now,
)
assert ret == AUTO_START_STOP_ACTION_OFF
assert algo.last_switch_date is not None
assert algo.last_switch_date == now
last_now = now
# 2. now we should turn on but to near the last change -> no nothing to do
now = now + timedelta(minutes=2)
algo._accumulated_error = -100
ret = algo.calculate_action(
hvac_mode=HVACMode.OFF,
saved_hvac_mode=HVACMode.HEAT,
target_temp=21,
current_temp=17,
slope_min=-0.1,
now=now,
)
assert ret == AUTO_START_STOP_ACTION_NOTHING
assert algo.last_switch_date == last_now
# 3. now we should turn on and now is much later ->
now = now + timedelta(minutes=30)
algo._accumulated_error = -100
ret = algo.calculate_action(
hvac_mode=HVACMode.OFF,
saved_hvac_mode=HVACMode.HEAT,
target_temp=21,
current_temp=17,
slope_min=-0.1,
now=now,
)
assert ret == AUTO_START_STOP_ACTION_ON
assert algo.last_switch_date == now
last_now = now
#
# Testing with turn_off
#
# 4. try to turn_off but too speed (29 min)
now = now + timedelta(minutes=29)
algo._accumulated_error = -100
ret = algo.calculate_action(
hvac_mode=HVACMode.HEAT,
saved_hvac_mode=HVACMode.OFF,
target_temp=17,
current_temp=21,
slope_min=0.5,
now=now,
)
assert ret == AUTO_START_STOP_ACTION_NOTHING
assert algo.last_switch_date == last_now
# 5. turn_off much later (29 min + 1 min)
now = now + timedelta(minutes=1)
algo._accumulated_error = -100
ret = algo.calculate_action(
hvac_mode=HVACMode.HEAT,
saved_hvac_mode=HVACMode.OFF,
target_temp=17,
current_temp=21,
slope_min=0.5,
now=now,
)
assert ret == AUTO_START_STOP_ACTION_OFF
assert algo.last_switch_date == now
async def test_auto_start_stop_algo_medium_cool_off(hass: HomeAssistant):

View File

@@ -21,7 +21,7 @@ logging.getLogger().setLevel(logging.DEBUG)
# @pytest.mark.parametrize("expected_lingering_tasks", [True])
# @pytest.mark.parametrize("expected_lingering_timers", [True])
# this test fails if run in // with the next because the underlying_valve_regulation is mixed. Don't know why
@pytest.mark.skip
# @pytest.mark.skip
async def test_over_climate_valve_mono(hass: HomeAssistant, skip_hass_states_get):
"""Test the normal full start of a thermostat in thermostat_over_climate type"""
@@ -300,7 +300,6 @@ async def test_over_climate_valve_mono(hass: HomeAssistant, skip_hass_states_get
await hass.async_block_till_done()
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_over_climate_valve_multi_presence(
hass: HomeAssistant, skip_hass_states_get
):