Compare commits

..

5 Commits

Author SHA1 Message Date
Jean-Marc Collin
9f238df4e7 Issue #698 - nb nb_device_active_for_boiler don't work for climate without hvac_action 2024-12-21 16:09:49 +00:00
Jean-Marc Collin
6226d26c6d With tests and list of active 2024-12-21 15:39:05 +00:00
Sebastian Noe
9839ed4920 Add attribute with active underlyings for easier tracking and setup (#658)
* Add attribute with active underlyings for easier tracking and setup

* Issue #645   add sonoff trvzb (#651)

* With Sonoff configuration ok

* Fix configuration

* Next (not finished)

* With 1rst implementation of VTherm TRVZB and underlying

* Work in simuated environment

* Fix Testus

* Release

* Fix release name

* Add #602 - implement a max_on_percent setting

* Calculate offset_calibration as room_temp - local_temp
Fix hvac_action calculation

* Fix hvac_action
Fix offset_calibration=room_temp - (local_temp - current_offset)

* Fix underlying target is not updated

* Issue #655 - combine motion and presence

* Fix Valve testus. Improve sending the open percent to valve

* Update custom_components/versatile_thermostat/translations/en.json

Co-authored-by: Alexander Dransfield <2844540+alexdrans@users.noreply.github.com>

* Indus step1

* Step 2 - renaming. All tests ok

* Step 2: manual tests ok

* First unit test ok

* Test multi ok

* All tests ok. Add a multi test for climate with valve regulation

* With testu for config_flow ok

* Documentation (not finished)

* Fix #661 - central boiler doesn't starts with Sonoff TRVZB

* Remove // testing

* Fix exception when there is no offset at all

* Fix class attributes and instance attributes mixing

* Documentation 2

* Documentation 3

* Documentation ++

* documentation

* Try to fix the central boiler calculation

* Fix #669

* Documentation ++

* Documentation ok for FR

* Readme FR|EN

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
Co-authored-by: Alexander Dransfield <2844540+alexdrans@users.noreply.github.com>

* Documentation rework

* En links

* Documentation issue #650

---------

Co-authored-by: Sebastian Noe <sebastian.schneider@boxine.de>
Co-authored-by: Jean-Marc Collin <jm.collin.78@gmail.com>
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
Co-authored-by: Alexander Dransfield <2844540+alexdrans@users.noreply.github.com>
2024-12-21 09:36:46 +01:00
Jean-Marc Collin
02f60770e8 Try to fix issue #702 2024-12-21 08:28:13 +00:00
Edwin ten Haaf
23ddff95b3 fix for 'It's not possible to set regulation mode to Expert using Automations' (#718)
Co-authored-by: Edwin ten Haaf <edwin.ten.haaf@rawworks.nl>
2024-12-20 08:41:16 +01:00
7 changed files with 436 additions and 40 deletions

View File

@@ -82,6 +82,10 @@ T = TypeVar("T", bound=UnderlyingEntity)
class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
"""Representation of a base class for all Versatile Thermostat device."""
# breaking change with 2024.12 climate workaround
_attr_swing_horizontal_modes = []
_attr_swing_horizontal_mode = ""
_entity_component_unrecorded_attributes = (
ClimateEntity._entity_component_unrecorded_attributes.union(
frozenset(
@@ -127,7 +131,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
"max_power_sensor_entity_id",
"temperature_unit",
"is_device_active",
"nb_device_actives",
"device_actives",
"target_temperature_step",
"is_used_by_central_boiler",
"temperature_slope",
@@ -997,14 +1001,19 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
return False
@property
def nb_device_actives(self) -> int:
"""Calculate the number of active devices"""
ret = 0
def device_actives(self) -> int:
"""Calculate the active devices"""
ret = []
for under in self._underlyings:
if under.is_device_active:
ret += 1
ret.append(under.entity_id)
return ret
@property
def nb_device_actives(self) -> int:
"""Calculate the number of active devices"""
return len(self.device_actives)
@property
def current_temperature(self) -> float | None:
"""Return the sensor temperature."""
@@ -2676,6 +2685,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
"timezone": str(self._current_tz),
"temperature_unit": self.temperature_unit,
"is_device_active": self.is_device_active,
"device_actives": self.device_actives,
"nb_device_actives": self.nb_device_actives,
"ema_temp": self._ema_temp,
"is_used_by_central_boiler": self.is_used_by_central_boiler,

View File

@@ -118,7 +118,7 @@ async def async_setup_entry(
SERVICE_SET_AUTO_REGULATION_MODE,
{
vol.Required("auto_regulation_mode"): vol.In(
["None", "Light", "Medium", "Strong", "Slow"]
["None", "Light", "Medium", "Strong", "Slow", "Expert"]
),
},
"service_set_auto_regulation_mode",

View File

@@ -644,6 +644,10 @@ class NbActiveDeviceForBoilerSensor(SensorEntity):
"""Representation of the threshold of the number of VTherm
which should be active to activate the boiler"""
_entity_component_unrecorded_attributes = SensorEntity._entity_component_unrecorded_attributes.union( # pylint: disable=protected-access
frozenset({"active_device_ids"})
)
def __init__(self, hass: HomeAssistant, unique_id, name, entry_infos) -> None:
"""Initialize the energy sensor"""
self._hass = hass
@@ -653,6 +657,14 @@ class NbActiveDeviceForBoilerSensor(SensorEntity):
self._attr_unique_id = "nb_device_active_boiler"
self._attr_value = self._attr_native_value = None # default value
self._entities = []
self._attr_active_device_ids = [] # Holds the entity ids of active devices
@property
def extra_state_attributes(self) -> dict:
"""Return additional attributes for the sensor."""
return {
"active_device_ids": self._attr_active_device_ids,
}
@property
def icon(self) -> str | None:
@@ -718,19 +730,19 @@ class NbActiveDeviceForBoilerSensor(SensorEntity):
self.calculate_nb_active_devices,
)
_LOGGER.info(
"%s - the underlyings that could controls the central boiler are %s",
"%s - the underlyings that could control the central boiler are %s",
self,
underlying_entities_id,
)
self.async_on_remove(listener_cancel)
else:
_LOGGER.debug("%s - no VTherm could controls the central boiler", self)
_LOGGER.debug("%s - no VTherm could control the central boiler", self)
await self.calculate_nb_active_devices(None)
async def calculate_nb_active_devices(self, event: Event):
"""Calculate the number of active VTherm that have an
influence on central boiler"""
influence on the central boiler and update the list of active device names."""
# _LOGGER.debug("%s- calculate_nb_active_devices - the event is %s ", self, event)
@@ -757,6 +769,8 @@ class NbActiveDeviceForBoilerSensor(SensorEntity):
old_state is not None
and new_state.state == old_state.state
and new_hvac_action == old_hvac_action
# issue 698 - force recalculation when underlying climate doesn't have any hvac_action
and new_hvac_action is not None
):
# A false state change
return
@@ -774,20 +788,28 @@ class NbActiveDeviceForBoilerSensor(SensorEntity):
)
nb_active = 0
active_device_ids = []
for entity in self._entities:
nb_active += entity.nb_device_actives
device_actives = entity.device_actives
_LOGGER.debug(
"After examining the hvac_action of %s, nb_active is %s",
"After examining the hvac_action of %s, device_actives is %s",
entity.name,
nb_active,
device_actives,
)
nb_active += len(device_actives)
active_device_ids.extend(device_actives)
self._attr_native_value = nb_active
_LOGGER.debug(
"%s - Number of active underlying entities is %s", self, nb_active
)
self._attr_active_device_ids = active_device_ids
self.async_write_ha_state()
@property
def active_device_ids(self) -> list:
"""Get the list of active device id"""
return self._attr_active_device_ids
def __str__(self):
return f"VersatileThermostat-{self.name}"

View File

@@ -277,12 +277,15 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
return self.valve_open_percent > 0
@property
def nb_device_actives(self) -> int:
def device_actives(self) -> int:
"""Calculate the number of active devices"""
if self.is_device_active:
return len(self._underlyings_valve_regulation)
return [
under.opening_degree_entity_id
for under in self._underlyings_valve_regulation
]
else:
return 0
return []
@property
def activable_underlying_entities(self) -> list | None:

View File

@@ -579,6 +579,7 @@ class MockNumber(NumberEntity):
def set_native_value(self, value: float):
"""Change the value"""
self._attr_native_value = value
self.async_write_ha_state()
async def create_thermostat(

View File

@@ -2,7 +2,7 @@
""" Test the central_configuration """
import asyncio
from datetime import datetime
from datetime import datetime, timedelta
from unittest.mock import patch, call
@@ -29,6 +29,8 @@ from custom_components.versatile_thermostat.binary_sensor import (
CentralBoilerBinarySensor,
)
from custom_components.versatile_thermostat.sensor import NbActiveDeviceForBoilerSensor
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
@@ -103,7 +105,7 @@ async def test_update_central_boiler_state_simple(
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_HEATER: switch1.entity_id,
CONF_UNDERLYING_LIST: [switch1.entity_id],
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_INVERSE_SWITCH: False,
CONF_TPI_COEF_INT: 0.3,
@@ -147,6 +149,13 @@ async def test_update_central_boiler_state_simple(
assert boiler_binary_sensor is not None
assert boiler_binary_sensor.state == STATE_OFF
nb_device_active_sensor: NbActiveDeviceForBoilerSensor = search_entity(
hass, "sensor.nb_device_active_for_boiler", "sensor"
)
assert nb_device_active_sensor is not None
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
# 1. start a heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -195,6 +204,9 @@ async def test_update_central_boiler_state_simple(
assert api.nb_active_device_for_boiler == 1
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 1
assert nb_device_active_sensor.active_device_ids == ["switch.switch1"]
# 2. stop a heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -235,6 +247,9 @@ async def test_update_central_boiler_state_simple(
assert api.nb_active_device_for_boiler == 0
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
entity.remove_thermostat()
@@ -272,10 +287,12 @@ async def test_update_central_boiler_state_multiple(
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_HEATER: switch1.entity_id,
CONF_HEATER_2: switch2.entity_id,
CONF_HEATER_3: switch3.entity_id,
CONF_HEATER_4: switch4.entity_id,
CONF_UNDERLYING_LIST: [
switch1.entity_id,
switch2.entity_id,
switch3.entity_id,
switch4.entity_id,
],
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_INVERSE_SWITCH: False,
CONF_TPI_COEF_INT: 0.3,
@@ -302,10 +319,18 @@ async def test_update_central_boiler_state_multiple(
assert entity.underlying_entities[1].entity_id == "switch.switch2"
assert entity.underlying_entities[2].entity_id == "switch.switch3"
assert entity.underlying_entities[3].entity_id == "switch.switch4"
assert entity.nb_device_actives == 0
assert entity.device_actives == []
assert api.nb_active_device_for_boiler_threshold == 1
assert api.nb_active_device_for_boiler == 0
nb_device_active_sensor: NbActiveDeviceForBoilerSensor = search_entity(
hass, "sensor.nb_device_active_for_boiler", "sensor"
)
assert nb_device_active_sensor is not None
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
# Force the VTherm to heat
await entity.async_set_hvac_mode(HVACMode.HEAT)
await entity.async_set_preset_mode(PRESET_BOOST)
@@ -338,7 +363,7 @@ async def test_update_central_boiler_state_multiple(
await asyncio.sleep(0.1)
assert entity.hvac_action == HVACAction.HEATING
assert entity.nb_device_actives == 1
assert entity.device_actives == ["switch.switch1"]
assert mock_service_call.call_count == 1
# No switch of the boiler
@@ -356,6 +381,9 @@ async def test_update_central_boiler_state_multiple(
assert api.nb_active_device_for_boiler == 1
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 1
assert nb_device_active_sensor.active_device_ids == ["switch.switch1"]
# 2. start a 2nd heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -368,7 +396,7 @@ async def test_update_central_boiler_state_multiple(
await asyncio.sleep(0.1)
assert entity.hvac_action == HVACAction.HEATING
assert entity.nb_device_actives == 2
assert entity.device_actives == ["switch.switch1", "switch.switch2"]
# Only the first heater is started by the algo
assert mock_service_call.call_count == 1
@@ -388,6 +416,12 @@ async def test_update_central_boiler_state_multiple(
assert api.nb_active_device_for_boiler == 2
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 2
assert nb_device_active_sensor.active_device_ids == [
"switch.switch1",
"switch.switch2",
]
# 3. start a 3rd heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -436,6 +470,13 @@ async def test_update_central_boiler_state_multiple(
assert api.nb_active_device_for_boiler == 3
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 3
assert nb_device_active_sensor.active_device_ids == [
"switch.switch1",
"switch.switch2",
"switch.switch3",
]
# 4. start a 4th heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -466,6 +507,14 @@ async def test_update_central_boiler_state_multiple(
assert api.nb_active_device_for_boiler == 4
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 4
assert nb_device_active_sensor.active_device_ids == [
"switch.switch1",
"switch.switch2",
"switch.switch3",
"switch.switch4",
]
# 5. stop a heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -484,6 +533,13 @@ async def test_update_central_boiler_state_multiple(
assert api.nb_active_device_for_boiler == 3
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 3
assert nb_device_active_sensor.active_device_ids == [
"switch.switch2",
"switch.switch3",
"switch.switch4",
]
# 6. stop a 2nd heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -524,6 +580,12 @@ async def test_update_central_boiler_state_multiple(
assert api.nb_active_device_for_boiler == 2
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 2
assert nb_device_active_sensor.active_device_ids == [
"switch.switch2",
"switch.switch3",
]
entity.remove_thermostat()
@@ -558,7 +620,7 @@ async def test_update_central_boiler_state_simple_valve(
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_VALVE: valve1.entity_id,
CONF_UNDERLYING_LIST: [valve1.entity_id],
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_INVERSE_SWITCH: False,
CONF_TPI_COEF_INT: 0.3,
@@ -594,7 +656,7 @@ async def test_update_central_boiler_state_simple_valve(
now: datetime = datetime.now(tz=tz)
assert entity.hvac_mode == HVACMode.HEAT
assert entity.nb_device_actives == 0
assert entity.device_actives == []
boiler_binary_sensor: CentralBoilerBinarySensor = search_entity(
hass, "binary_sensor.central_boiler", "binary_sensor"
@@ -602,6 +664,13 @@ async def test_update_central_boiler_state_simple_valve(
assert boiler_binary_sensor is not None
assert boiler_binary_sensor.state == STATE_OFF
nb_device_active_sensor: NbActiveDeviceForBoilerSensor = search_entity(
hass, "sensor.nb_device_active_for_boiler", "sensor"
)
assert nb_device_active_sensor is not None
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
# 1. start a valve
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -616,7 +685,7 @@ async def test_update_central_boiler_state_simple_valve(
await asyncio.sleep(0.1)
assert entity.hvac_action == HVACAction.HEATING
assert entity.nb_device_actives == 1
assert entity.device_actives == ["number.valve1"]
assert mock_service_call.call_count >= 1
mock_service_call.assert_has_calls(
@@ -644,6 +713,11 @@ async def test_update_central_boiler_state_simple_valve(
assert api.nb_active_device_for_boiler == 1
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 1
assert nb_device_active_sensor.active_device_ids == [
"number.valve1",
]
# 2. stop a heater
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -658,7 +732,7 @@ async def test_update_central_boiler_state_simple_valve(
await asyncio.sleep(0.1)
assert entity.hvac_action == HVACAction.IDLE
assert entity.nb_device_actives == 0
assert entity.device_actives == []
assert mock_service_call.call_count >= 1
mock_service_call.assert_has_calls(
@@ -687,6 +761,9 @@ async def test_update_central_boiler_state_simple_valve(
assert api.nb_active_device_for_boiler == 0
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
entity.remove_thermostat()
@@ -721,7 +798,7 @@ async def test_update_central_boiler_state_simple_climate(
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: climate1.entity_id,
CONF_UNDERLYING_LIST: [climate1.entity_id],
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
@@ -748,6 +825,13 @@ async def test_update_central_boiler_state_simple_climate(
assert api.nb_active_device_for_boiler_threshold == 1
assert api.nb_active_device_for_boiler == 0
nb_device_active_sensor: NbActiveDeviceForBoilerSensor = search_entity(
hass, "sensor.nb_device_active_for_boiler", "sensor"
)
assert nb_device_active_sensor is not None
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
# Force the VTherm to heat
await entity.async_set_hvac_mode(HVACMode.HEAT)
await entity.async_set_preset_mode(PRESET_BOOST)
@@ -756,7 +840,7 @@ async def test_update_central_boiler_state_simple_climate(
now: datetime = datetime.now(tz=tz)
assert entity.hvac_mode == HVACMode.HEAT
assert entity.nb_device_actives == 0
assert entity.device_actives == []
boiler_binary_sensor: CentralBoilerBinarySensor = search_entity(
hass, "binary_sensor.central_boiler", "binary_sensor"
@@ -779,7 +863,7 @@ async def test_update_central_boiler_state_simple_climate(
await asyncio.sleep(0.5)
assert entity.hvac_action == HVACAction.HEATING
assert entity.nb_device_actives == 1
assert entity.device_actives == ["climate.climate1"]
assert mock_service_call.call_count >= 1
mock_service_call.assert_has_calls(
@@ -807,6 +891,11 @@ async def test_update_central_boiler_state_simple_climate(
assert api.nb_active_device_for_boiler == 1
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 1
assert nb_device_active_sensor.active_device_ids == [
"climate.climate1",
]
# 2. stop a climate
with patch(
"homeassistant.core.ServiceRegistry.async_call"
@@ -821,7 +910,7 @@ async def test_update_central_boiler_state_simple_climate(
await asyncio.sleep(0.5)
assert entity.hvac_action == HVACAction.IDLE
assert entity.nb_device_actives == 0
assert entity.device_actives == []
assert mock_service_call.call_count >= 1
mock_service_call.assert_has_calls(
@@ -850,6 +939,277 @@ async def test_update_central_boiler_state_simple_climate(
assert api.nb_active_device_for_boiler == 0
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
entity.remove_thermostat()
async def test_update_central_boiler_state_simple_climate_valve_regulation(
hass: HomeAssistant,
# skip_hass_states_is_state,
# skip_hass_states_get,
init_central_config_with_boiler_fixture,
):
"""Test that the central boiler state behavior with a climate with valve regulation"""
api = VersatileThermostatAPI.get_vtherm_api(hass)
climate1 = MockClimate(hass, "climate1", "theClimate1")
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverClimateMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 8,
CONF_TEMP_MAX: 18,
"frost_temp": 10,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 21,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_UNDERLYING_LIST: [climate1.entity_id],
CONF_OPENING_DEGREE_LIST: ["number.mock_opening_degree"],
CONF_CLOSING_DEGREE_LIST: [],
CONF_OFFSET_CALIBRATION_LIST: [],
CONF_AUTO_REGULATION_MODE: CONF_AUTO_REGULATION_VALVE,
CONF_AUTO_REGULATION_DTEMP: 0,
CONF_AUTO_REGULATION_PERIOD_MIN: 0,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.1,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_HIGH,
CONF_AUTO_REGULATION_USE_DEVICE_TEMP: False,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_USE_MAIN_CENTRAL_CONFIG: True,
CONF_USE_PRESETS_CENTRAL_CONFIG: True,
CONF_USE_ADVANCED_CENTRAL_CONFIG: True,
CONF_USED_BY_CENTRAL_BOILER: True,
},
)
open_degree_entity = MockNumber(hass, "mock_opening_degree", "Opening degree")
open_degree_entity.set_native_value(0)
# mock_get_state will be called for each OPENING/CLOSING/OFFSET_CALIBRATION list
mock_get_state_side_effect = SideEffects(
{
open_degree_entity.entity_id: State(
open_degree_entity.entity_id,
open_degree_entity.state,
{"min": 0, "max": 100},
),
"number.mock_closing_degree": State(
"number.mock_closing_degree", "0", {"min": 0, "max": 100}
),
"number.mock_offset_calibration": State(
"number.mock_offset_calibration", "0", {"min": -12, "max": 12}
),
},
State("unknown.entity_id", "unknown"),
)
with patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=climate1,
), patch(
"homeassistant.core.StateMachine.get",
side_effect=mock_get_state_side_effect.get_side_effects(),
):
entity: ThermostatOverClimate = await create_thermostat(
hass, entry, "climate.theoverclimatemockname"
)
assert entity
assert entity.name == "TheOverClimateMockName"
assert entity.is_over_climate
assert entity.underlying_entities[0].entity_id == "climate.climate1"
assert api.nb_active_device_for_boiler_threshold == 1
assert api.nb_active_device_for_boiler == 0
nb_device_active_sensor: NbActiveDeviceForBoilerSensor = search_entity(
hass, "sensor.nb_device_active_for_boiler", "sensor"
)
assert nb_device_active_sensor is not None
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
# Force the VTherm to heat
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
entity._set_now(now)
await send_temperature_change_event(entity, 30, now)
await send_ext_temperature_change_event(entity, 30, now)
await hass.async_block_till_done()
await entity.async_set_hvac_mode(HVACMode.HEAT)
await entity.async_set_preset_mode(PRESET_BOOST)
# the VTherm should not heat now
assert entity.hvac_mode == HVACMode.HEAT
assert entity.hvac_action == HVACAction.OFF
assert entity.activable_underlying_entities[0]._percent_open == 0
assert entity.device_actives == []
boiler_binary_sensor: CentralBoilerBinarySensor = search_entity(
hass, "binary_sensor.central_boiler", "binary_sensor"
)
assert boiler_binary_sensor is not None
assert boiler_binary_sensor.state == STATE_OFF
# 1. start a climate
open_degree_entity.set_native_value(100)
mock_get_state_side_effect = SideEffects(
{
open_degree_entity.entity_id: State(
open_degree_entity.entity_id,
open_degree_entity.state,
{"min": 0, "max": 100},
),
"number.mock_closing_degree": State(
"number.mock_closing_degree", "0", {"min": 0, "max": 100}
),
"number.mock_offset_calibration": State(
"number.mock_offset_calibration", "0", {"min": -12, "max": 12}
),
},
State("unknown.entity_id", "unknown"),
)
with patch(
"homeassistant.core.ServiceRegistry.async_call"
) as mock_service_call, patch(
"custom_components.versatile_thermostat.binary_sensor.send_vtherm_event"
) as mock_send_event, patch(
"homeassistant.core.StateMachine.get",
side_effect=mock_get_state_side_effect.get_side_effects(),
):
now = now + timedelta(minutes=1)
entity._set_now(now)
await send_temperature_change_event(entity, 10, now)
# we have to simulate the climate also else the test don't work
climate1.set_hvac_mode(HVACMode.HEAT)
climate1.set_hvac_action(HVACAction.HEATING)
climate1.async_write_ha_state()
open_degree_entity.set_native_value(100)
# Wait for state event propagation
await hass.async_block_till_done()
assert entity.hvac_action == HVACAction.HEATING
assert entity.device_actives == ["number.mock_opening_degree"]
assert api.nb_active_device_for_boiler == 1
assert boiler_binary_sensor.state == STATE_ON
assert nb_device_active_sensor.state == 1
assert nb_device_active_sensor.active_device_ids == [
"number.mock_opening_degree",
]
assert mock_service_call.call_count >= 1
mock_service_call.assert_has_calls(
[
call.service_call(
"switch",
"turn_on",
service_data={},
target={"entity_id": "switch.pompe_chaudiere"},
),
]
)
assert mock_send_event.call_count >= 1
mock_send_event.assert_has_calls(
[
call.send_vtherm_event(
hass=hass,
event_type=EventType.CENTRAL_BOILER_EVENT,
entity=api.central_boiler_entity,
data={"central_boiler": True},
)
]
)
# 2. stop a climate
open_degree_entity.set_native_value(0)
mock_get_state_side_effect = SideEffects(
{
open_degree_entity.entity_id: State(
open_degree_entity.entity_id,
open_degree_entity.state,
{"min": 0, "max": 100},
),
"number.mock_closing_degree": State(
"number.mock_closing_degree", "0", {"min": 0, "max": 100}
),
"number.mock_offset_calibration": State(
"number.mock_offset_calibration", "0", {"min": -12, "max": 12}
),
},
State("unknown.entity_id", "unknown"),
)
with patch(
"homeassistant.core.ServiceRegistry.async_call"
) as mock_service_call, patch(
"custom_components.versatile_thermostat.binary_sensor.send_vtherm_event"
) as mock_send_event, patch(
"homeassistant.core.StateMachine.get",
side_effect=mock_get_state_side_effect.get_side_effects(),
):
await send_temperature_change_event(entity, 25, now)
climate1.set_hvac_mode(HVACMode.HEAT)
climate1.set_hvac_action(HVACAction.IDLE)
climate1.async_write_ha_state()
open_degree_entity.set_native_value(0)
# Wait for state event propagation
await asyncio.sleep(0.5)
assert entity.hvac_action == HVACAction.OFF
assert entity.device_actives == []
assert mock_service_call.call_count >= 1
mock_service_call.assert_has_calls(
[
call(
"switch",
"turn_off",
service_data={},
target={"entity_id": "switch.pompe_chaudiere"},
)
]
)
assert mock_send_event.call_count >= 1
mock_send_event.assert_has_calls(
[
call.send_vtherm_event(
hass=hass,
event_type=EventType.CENTRAL_BOILER_EVENT,
entity=api.central_boiler_entity,
data={"central_boiler": False},
)
]
)
assert api.nb_active_device_for_boiler == 0
assert boiler_binary_sensor.state == STATE_OFF
assert nb_device_active_sensor.state == 0
assert nb_device_active_sensor.active_device_ids == []
entity.remove_thermostat()

View File

@@ -18,10 +18,10 @@ from .const import *
logging.getLogger().setLevel(logging.DEBUG)
# @pytest.mark.parametrize("expected_lingering_tasks", [True])
# @pytest.mark.parametrize("expected_lingering_timers", [True])
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
# this test fails if run in // with the next because the underlying_valve_regulation is mixed. Don't know why
@pytest.mark.skip
# @pytest.mark.skip
async def test_over_climate_valve_mono(hass: HomeAssistant, skip_hass_states_get):
"""Test the normal full start of a thermostat in thermostat_over_climate type"""
@@ -138,13 +138,13 @@ async def test_over_climate_valve_mono(hass: HomeAssistant, skip_hass_states_get
assert mock_service_call.call_count == 3
mock_service_call.assert_has_calls(
[
call(domain='number', service='set_value', service_data={'value': 0}, target={'entity_id': 'number.mock_opening_degree'}),
call(domain='number', service='set_value', service_data={'value': 100}, target={'entity_id': 'number.mock_closing_degree'}),
call("climate","set_temperature",{
"entity_id": "climate.mock_climate",
"temperature": 15, # temp-min
},
),
call(domain='number', service='set_value', service_data={'value': 0}, target={'entity_id': 'number.mock_opening_degree'}),
call(domain='number', service='set_value', service_data={'value': 100}, target={'entity_id': 'number.mock_closing_degree'}),
# we have no current_temperature yet
# call(domain='number', service='set_value', service_data={'value': 12}, target={'entity_id': 'number.mock_offset_calibration'}),
]