Compare commits
14 Commits
6.5.0.beta
...
6.6.3.beta
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
ba69319198 | ||
|
|
f9df925181 | ||
|
|
2d72efe447 | ||
|
|
95af6eba97 | ||
|
|
06dc537767 | ||
|
|
2d79d961dc | ||
|
|
027bf8386b | ||
|
|
a0e548ef71 | ||
|
|
132519b471 | ||
|
|
e6c330fc9d | ||
|
|
968e8286ea | ||
|
|
0f60c070ab | ||
|
|
810430f7b1 | ||
|
|
b4860c2b8d |
@@ -152,6 +152,7 @@ climate:
|
||||
name: Underlying thermostat2
|
||||
heater: input_boolean.fake_heater_switch3
|
||||
target_sensor: input_number.fake_temperature_sensor1
|
||||
ac_mode: false
|
||||
- platform: generic_thermostat
|
||||
name: Underlying thermostat3
|
||||
heater: input_boolean.fake_heater_switch3
|
||||
|
||||
2
.github/ISSUE_TEMPLATE/issue.md
vendored
2
.github/ISSUE_TEMPLATE/issue.md
vendored
@@ -4,6 +4,8 @@ about: Create a report to help us improve
|
||||
|
||||
---
|
||||
|
||||
> Please read carefuly this instructions and fill this form before writing an issue. It helps me to help you.
|
||||
|
||||
<!-- This template will allow the maintainer to be efficient and post the more accurante response as possible. There is many types / modes / configuration possible, so the analysis can be very tricky. If don't follow this template, your issue could be rejected without any message. Please help me to help you. -->
|
||||
|
||||
<!-- Before you open a new issue, search through the existing issues to see if others have had the same problem.
|
||||
|
||||
28
README-fr.md
28
README-fr.md
@@ -31,6 +31,7 @@
|
||||
- [Compensation de la température interne](#compensation-de-la-température-interne)
|
||||
- [Synthèse de l'algorithme d'auto-régulation](#synthèse-de-lalgorithme-dauto-régulation)
|
||||
- [Le mode auto-fan](#le-mode-auto-fan)
|
||||
- [Le démarrage / arrêt automatique](#le-démarrage--arrêt-automatique)
|
||||
- [Pour un thermostat de type ```thermostat_over_valve```:](#pour-un-thermostat-de-type-thermostat_over_valve)
|
||||
- [Configurez les coefficients de l'algorithme TPI](#configurez-les-coefficients-de-lalgorithme-tpi)
|
||||
- [Configurer les températures préréglées](#configurer-les-températures-préréglées)
|
||||
@@ -92,6 +93,9 @@ Ce composant personnalisé pour Home Assistant est une mise à niveau et est une
|
||||
|
||||
|
||||
>  _*Historique des dernières versions*_
|
||||
> * **Release 6.5** :
|
||||
> - Ajout d'une nouvelle fonction permettant l'arrêt et la relance automatique d'un VTherm `over_climate` [585](https://github.com/jmcollin78/versatile_thermostat/issues/585)
|
||||
> - Amélioration de la gestion des ouvertures au démarrage. Permet de mémoriser et de recalculer l'état d'une ouverture au redémarage de Home Assistant [504](https://github.com/jmcollin78/versatile_thermostat/issues/504)
|
||||
> * **Release 6.0** :
|
||||
> - Ajout d'entités du domaine Number permettant de configurer les températures des presets [354](https://github.com/jmcollin78/versatile_thermostat/issues/354)
|
||||
> - Refonte complète du menu de configuration pour supprimer les températures et utililsation d'un menu au lieu d'un tunnel de configuration [354](https://github.com/jmcollin78/versatile_thermostat/issues/354)
|
||||
@@ -100,14 +104,14 @@ Ce composant personnalisé pour Home Assistant est une mise à niveau et est une
|
||||
> - ajout de seuils de régulation pour les `over_valve` pour éviter de trop vider la batterie des TRV [#338](https://github.com/jmcollin78/versatile_thermostat/issues/338),
|
||||
> - ajout d'une option permettant d'utiliser la température interne d'un TRV pour forcer l' auto-régulation [#348](https://github.com/jmcollin78/versatile_thermostat/issues/348),
|
||||
> - ajout d'une fonction de keep-alive pour les VTherm `over_switch` [#345](https://github.com/jmcollin78/versatile_thermostat/issues/345)
|
||||
> * **Release 5.3** : Ajout d'une fonction de pilotage d'une chaudière centrale [#234](https://github.com/jmcollin78/versatile_thermostat/issues/234) - plus d'infos ici: [Le contrôle d'une chaudière centrale](#le-contrôle-dune-chaudière-centrale). Ajout de la possibilité de désactiver le mode sécurité pour le thermomètre extérieur [#343](https://github.com/jmcollin78/versatile_thermostat/issues/343)
|
||||
> * **Release 5.2** : Ajout d'un `central_mode` permettant de piloter tous les VTherms de façon centralisée [#158](https://github.com/jmcollin78/versatile_thermostat/issues/158).
|
||||
> * **Release 5.1** : Limitation des valeurs envoyées aux valves et au température envoyées au climate sous-jacent.
|
||||
> * **Release 5.0** : Ajout d'une configuration centrale permettant de mettre en commun les attributs qui peuvent l'être [#239](https://github.com/jmcollin78/versatile_thermostat/issues/239).
|
||||
|
||||
<details>
|
||||
<summary>Autres versions</summary>
|
||||
|
||||
> * **Release 5.3** : Ajout d'une fonction de pilotage d'une chaudière centrale [#234](https://github.com/jmcollin78/versatile_thermostat/issues/234) - plus d'infos ici: [Le contrôle d'une chaudière centrale](#le-contrôle-dune-chaudière-centrale). Ajout de la possibilité de désactiver le mode sécurité pour le thermomètre extérieur [#343](https://github.com/jmcollin78/versatile_thermostat/issues/343)
|
||||
> * **Release 5.2** : Ajout d'un `central_mode` permettant de piloter tous les VTherms de façon centralisée [#158](https://github.com/jmcollin78/versatile_thermostat/issues/158).
|
||||
> * **Release 5.1** : Limitation des valeurs envoyées aux valves et au température envoyées au climate sous-jacent.
|
||||
> * **Release 5.0** : Ajout d'une configuration centrale permettant de mettre en commun les attributs qui peuvent l'être [#239](https://github.com/jmcollin78/versatile_thermostat/issues/239).
|
||||
> * **Release 4.3** : Ajout d'un mode auto-fan pour le type `over_climate` permettant d'activer la ventilation si l'écart de température est important [#223](https://github.com/jmcollin78/versatile_thermostat/issues/223).
|
||||
> * **Release 4.2** : Le calcul de la pente de la courbe de température se fait maintenant en °/heure et non plus en °/min [#242](https://github.com/jmcollin78/versatile_thermostat/issues/242). Correction de la détection automatique des ouvertures par l'ajout d'un lissage de la courbe de température .
|
||||
> * **Release 4.1** : Ajout d'un mode de régulation **Expert** dans lequel l'utilisateur peut spécifier ses propres paramètres d'auto-régulation au lieu d'utiliser les pre-programmés [#194](https://github.com/jmcollin78/versatile_thermostat/issues/194).
|
||||
@@ -510,6 +514,17 @@ Il faut évidemment que votre équipement sous-jacent soit équipée d'une venti
|
||||
Si votre équipement ne comprend pas le mode Turbo, le mode Forte` sera utilisé en remplacement.
|
||||
Une fois l'écart de température redevenu faible, la ventilation se mettra dans un mode "normal" qui dépend de votre équipement à savoir (dans l'ordre) : `Silence (mute)`, `Auto (auto)`, `Faible (low)`. La première valeur qui est possible pour votre équipement sera choisie.
|
||||
|
||||
#### Le démarrage / arrêt automatique
|
||||
Cette fonction a été introduite en 6.5.0. Elle permet d'autoriser VTherm a stopper un équipement qui n'a pas besoin d'être allumé et de le redémarrer lorsque les conditions le réclame. Cette fonction est munie de 3 réglages qui permettent d'arrêter / relancer plus ou moins rapidement l'équipement.
|
||||
|
||||
Pour l'utiliser, vous devez :
|
||||
1. Ajouter la fonction `Avec démmarrage et extinction automatique` dans le menu 'Fonctions',
|
||||
2. Paramétrer le niveau de détection dans l'option 'Allumage/extinction automatique' qui s'affiche lorsque la fonction a été activée. Vous choisissez le niveau de détection entre 'Lent', 'Moyen' et 'Rapide'. Les arrêts/relances seront plus nombreux avec le niveau 'Rapide'.
|
||||
|
||||
Une fois paramétré, vous aurez maintenant une nouvelle entité de type `switch` qui vous permet d'autoriser ou non l'arrêt/relance automatique sans toucher à la configuration. Cette entité est disponible sur l'appareil VTherm et se nomme `switch.<name>_enable_auto_start_stop`. Cochez la pour autoriser le démarrage et extinction automatique.
|
||||
|
||||
L'algorithme de détection est décrit [ici](https://github.com/jmcollin78/versatile_thermostat/issues/585).
|
||||
|
||||
### Pour un thermostat de type ```thermostat_over_valve```:
|
||||

|
||||
Vous pouvez choisir jusqu'à entité du domaine ```number``` ou ```ìnput_number``` qui vont commander les vannes.
|
||||
@@ -911,6 +926,8 @@ context:
|
||||
| ``central_boiler_activation_service`` | Service d'activation de la chaudière | - | - | - | X |
|
||||
| ``central_boiler_deactivation_service`` | Service de desactivation de la chaudière | - | - | - | X |
|
||||
| ``used_by_controls_central_boiler`` | Indique si le VTherm contrôle la chaudière centrale | X | X | X | - |
|
||||
| ``use_auto_start_stop_feature`` | Indique si la fonction de démarrage/extinction automatique est activée | - | X | - | - |
|
||||
| ``auto_start_stop_lvel`` | Le niveau de détection de l'auto start/stop | - | X | - | - |
|
||||
</details>
|
||||
|
||||
# Exemples de réglage
|
||||
@@ -1168,6 +1185,9 @@ Les attributs personnalisés sont les suivants :
|
||||
| ``is_controlled_by_central_mode`` | True si le VTherm peut être controlé de façon centrale |
|
||||
| ``last_central_mode`` | Le dernier mode central utilisé (None si le VTherm n'est pas controlé en central) |
|
||||
| ``is_used_by_central_boiler`` | Indique si le VTherm peut contrôler la chaudière centrale |
|
||||
| ``auto_start_stop_enable`` | Indique si le VTherm est autorisé à s'auto démarrer/arrêter |
|
||||
| ``auto_start_stop_level`` | Indique le niveau d'auto start/stop |
|
||||
| ``hvac_off_reason`` | Indique la raison de l'arrêt (hvac_off) du VTherm. Ce peut être Window, Auto-start/stop ou Manuel |
|
||||
|
||||
# Quelques résultats
|
||||
|
||||
|
||||
28
README.md
28
README.md
@@ -32,6 +32,7 @@
|
||||
- [Internal temperature compensation](#internal-temperature-compensation)
|
||||
- [synthesis of the self-regulation algorithm](#synthesis-of-the-self-regulation-algorithm)
|
||||
- [Auto-fan mode](#auto-fan-mode)
|
||||
- [Automatic start/stop](#automatic-startstop)
|
||||
- [For a thermostat of type ```thermostat_over_valve```:](#for-a-thermostat-of-type-thermostat_over_valve)
|
||||
- [Configure the TPI algorithm coefficients](#configure-the-tpi-algorithm-coefficients)
|
||||
- [Configure the preset temperature](#configure-the-preset-temperature)
|
||||
@@ -93,6 +94,9 @@
|
||||
This custom component for Home Assistant is an upgrade and is a complete rewrite of the component "Awesome thermostat" (see [Github](https://github.com/dadge/awesome_thermostat)) with addition of features.
|
||||
|
||||
> _*Latest releases*_
|
||||
> * **Release 6.5** :
|
||||
> - Added a new function allowing the automatic shutdown and restart of a VTherm `over_climate` [585](https://github.com/jmcollin78/versatile_thermostat/issues/585)
|
||||
> - Improved management of openings at startup. Allows to memorize and recalculate the state of an opening when restarting Home Assistant [504](https://github.com/jmcollin78/versatile_thermostat/issues/504)
|
||||
> * **Release 6.0**:
|
||||
> - Added entities from the Number domain to configure preset temperatures [354](https://github.com/jmcollin78/versatile_thermostat/issues/354)
|
||||
> - Complete redesign of the configuration menu to remove temperatures and use a menu instead of a configuration tunnel [354](https://github.com/jmcollin78/versatile_thermostat/issues/354)
|
||||
@@ -101,13 +105,13 @@ This custom component for Home Assistant is an upgrade and is a complete rewrite
|
||||
> - addition of regulation thresholds for the `over_valve` to avoid draining the TRV battery too much [#338](https://github.com/jmcollin78/versatile_thermostat/issues/338),
|
||||
> - added an option allowing the internal temperature of a TRV to be used to force self-regulation [#348](https://github.com/jmcollin78/versatile_thermostat/issues/348),
|
||||
> - added a keep-alive function for VTherm `over_switch` [#345](https://github.com/jmcollin78/versatile_thermostat/issues/345)
|
||||
<details>
|
||||
<summary>Others releases</summary>
|
||||
|
||||
> * **Release 5.3**: Added a central boiler control function [#234](https://github.com/jmcollin78/versatile_thermostat/issues/234) - more information here: [Controlling a central boiler](#controlling-a-central-boiler). Added the ability to disable security mode for outdoor thermometer [#343](https://github.com/jmcollin78/versatile_thermostat/issues/343)
|
||||
> * **Release 5.2**: Added a `central_mode` allowing all VTherms to be controlled centrally [#158](https://github.com/jmcollin78/versatile_thermostat/issues/158).
|
||||
> * **Release 5.1**: Limitation of the values sent to the valves and the temperature sent to the underlying climate.
|
||||
> * **Release 5.0**: Added a central configuration allowing the sharing of attributes that can be shared [#239](https://github.com/jmcollin78/versatile_thermostat/issues/239).
|
||||
<details>
|
||||
<summary>Others releases</summary>
|
||||
|
||||
> * **Release 4.3**: Added an auto-fan mode for the `over_climate` type allowing ventilation to be activated if the temperature difference is significant [#223](https://github.com/jmcollin78/versatile_thermostat/issues/223).
|
||||
> * **Release 4.2**: The calculation of the slope of the temperature curve is now done in °/hour and no longer in °/min [#242](https://github.com/jmcollin78/versatile_thermostat/issues/242). Correction of automatic detection of openings by adding smoothing of the temperature curve.
|
||||
> * **Release 4.1**: Added an **Expert** regulation mode in which the user can specify their own auto-regulation parameters instead of using the pre-programmed ones [#194]( https://github.com/jmcollin78/versatile_thermostat/issues/194).
|
||||
@@ -500,6 +504,17 @@ Obviously your underlying equipment must be equipped with ventilation and be con
|
||||
If your equipment does not include Turbo mode, Forte` mode will be used as a replacement.
|
||||
Once the temperature difference becomes low again, the ventilation will go into a "normal" mode which depends on your equipment, namely (in order): `Silence (mute)`, `Auto (auto)`, `Low (low)`. The first value that is possible for your equipment will be chosen.
|
||||
|
||||
#### Automatic start/stop
|
||||
This function was introduced in 6.5.0. It allows VTherm to stop equipment that does not need to be turned on and to restart it when conditions require it. This function has 3 settings that allow the equipment to be stopped/restarted more or less quickly.
|
||||
|
||||
To use it, you must:
|
||||
1. Add the `Use the auto start and stop feature` function in the 'Features' menu,
|
||||
2. Set the detection level in the `Auto start and stop` option that is displayed when the function has been activated. You choose the detection level between 'Slow', 'Medium' and 'Fast'. The 'Fast' level will result in more shutdowns/restarts.
|
||||
|
||||
Once configured, you will now have a new entity of type `switch` that allows you to authorize or not the automatic shutdown/restart without touching the configuration. This entity is available on the VTherm device and is called `switch.<name>_enable_auto_start_stop`. Check it to authorize the automatic startup and shutdown.
|
||||
|
||||
The detection algorithm is described [here](https://github.com/jmcollin78/versatile_thermostat/issues/585).
|
||||
|
||||
### For a thermostat of type ```thermostat_over_valve```:
|
||||

|
||||
You can choose up to domain entity ```number``` or ```ìnput_number``` which will control the valves.
|
||||
@@ -900,6 +915,8 @@ context:
|
||||
| ``central_boiler_activation_service`` | Activation service of the boiler | - | - | - | X |
|
||||
| ``central_boiler_deactivation_service`` | Deactivaiton service of the boiler | - | - | - | X |
|
||||
| ``used_by_controls_central_boiler`` | Indicate if the VTherm control the central boiler | X | X | X | - |
|
||||
| ``use_auto_start_stop_feature`` | Indique si la fonction de démarrage/extinction automatique est activée | - | X | - | - |
|
||||
| ``auto_start_stop_lvel`` | Le niveau de détection de l'auto start/stop | - | X | - | - |
|
||||
</details>
|
||||
|
||||
# Tuning examples
|
||||
@@ -1155,6 +1172,9 @@ Custom attributes are the following:
|
||||
| ``is_controlled_by_central_mode`` | True if the VTherm can be centrally controlled |
|
||||
| ``last_central_mode`` | The last central mode used (None if the VTherm is not centrally controlled) |
|
||||
| ``is_used_by_central_boiler`` | Indicate if the VTherm can control the central boiler |
|
||||
| ``auto_start_stop_enable`` | Indicate if the VTherm is allowed to do auto start and stop |
|
||||
| ``auto_start_stop_level`` | Give the level of auto start/stop |
|
||||
| ``hvac_off_reason`` | Give the reason of stop of the VTherm. This could be Window, Auto-start/stop or Manual |
|
||||
|
||||
# Some results
|
||||
|
||||
@@ -1333,7 +1353,7 @@ Example of graph obtained with Plotly :
|
||||
|
||||
|
||||
## And always better and better with the NOTIFIER daemon app to notify events
|
||||
This automation uses the excellent App Daemon named NOTIFIER developed by Horizon Domotique that you will find in demonstration [here](https://www.youtube.com/watch?v=chJylIK0ASo&ab_channel=HorizonDomotique) and the code is [here](https ://github.com/jlpouffier/home-assistant-config/blob/master/appdaemon/apps/notifier.py). It allows you to notify the users of the accommodation when one of the events affecting safety occurs on one of the Versatile Thermostats.
|
||||
This automation uses the excellent App Daemon named NOTIFIER developed by Horizon Domotique that you will find in demonstration [here](https://www.youtube.com/watch?v=chJylIK0ASo&ab_channel=HorizonDomotique) and the code is [here](https://github.com/jlpouffier/home-assistant-config/blob/master/appdaemon/apps/notifier.py). It allows you to notify the users of the accommodation when one of the events affecting safety occurs on one of the Versatile Thermostats.
|
||||
|
||||
This is a great example of using the notifications described here [notification](#notifications).
|
||||
|
||||
|
||||
@@ -38,6 +38,22 @@ from .const import (
|
||||
CONF_USE_CENTRAL_BOILER_FEATURE,
|
||||
CONF_POWER_SENSOR,
|
||||
CONF_PRESENCE_SENSOR,
|
||||
CONF_UNDERLYING_LIST,
|
||||
CONF_HEATER,
|
||||
CONF_HEATER_2,
|
||||
CONF_HEATER_3,
|
||||
CONF_HEATER_4,
|
||||
CONF_CLIMATE,
|
||||
CONF_CLIMATE_2,
|
||||
CONF_CLIMATE_3,
|
||||
CONF_CLIMATE_4,
|
||||
CONF_VALVE,
|
||||
CONF_VALVE_2,
|
||||
CONF_VALVE_3,
|
||||
CONF_VALVE_4,
|
||||
CONF_THERMOSTAT_SWITCH,
|
||||
CONF_THERMOSTAT_CLIMATE,
|
||||
CONF_THERMOSTAT_VALVE,
|
||||
)
|
||||
|
||||
from .vtherm_api import VersatileThermostatAPI
|
||||
@@ -162,13 +178,20 @@ async def async_setup_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
|
||||
|
||||
if hass.state == CoreState.running:
|
||||
await api.reload_central_boiler_entities_list()
|
||||
await api.init_vtherm_links()
|
||||
await api.init_vtherm_links(entry.entry_id)
|
||||
|
||||
return True
|
||||
|
||||
|
||||
async def update_listener(hass: HomeAssistant, entry: ConfigEntry) -> None:
|
||||
"""Update listener."""
|
||||
|
||||
_LOGGER.debug(
|
||||
"Calling update_listener entry: entry_id='%s', value='%s'",
|
||||
entry.entry_id,
|
||||
entry.data,
|
||||
)
|
||||
|
||||
if entry.data.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_CENTRAL_CONFIG:
|
||||
await reload_all_vtherm(hass)
|
||||
else:
|
||||
@@ -177,7 +200,7 @@ async def update_listener(hass: HomeAssistant, entry: ConfigEntry) -> None:
|
||||
api: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api(hass)
|
||||
if api is not None:
|
||||
await api.reload_central_boiler_entities_list()
|
||||
await api.init_vtherm_links()
|
||||
await api.init_vtherm_links(entry.entry_id)
|
||||
|
||||
|
||||
async def async_unload_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
|
||||
@@ -208,10 +231,9 @@ async def async_migrate_entry(hass: HomeAssistant, config_entry: ConfigEntry):
|
||||
)
|
||||
new = {**config_entry.data}
|
||||
|
||||
if (
|
||||
config_entry.data.get(CONF_THERMOSTAT_TYPE)
|
||||
== CONF_THERMOSTAT_CENTRAL_CONFIG
|
||||
):
|
||||
thermostat_type = config_entry.data.get(CONF_THERMOSTAT_TYPE)
|
||||
|
||||
if thermostat_type == CONF_THERMOSTAT_CENTRAL_CONFIG:
|
||||
new[CONF_USE_WINDOW_FEATURE] = True
|
||||
new[CONF_USE_MOTION_FEATURE] = True
|
||||
new[CONF_USE_POWER_FEATURE] = new.get(CONF_POWER_SENSOR, None) is not None
|
||||
@@ -223,6 +245,50 @@ async def async_migrate_entry(hass: HomeAssistant, config_entry: ConfigEntry):
|
||||
"add_central_boiler_control", False
|
||||
) or new.get(CONF_USE_CENTRAL_BOILER_FEATURE, False)
|
||||
|
||||
if config_entry.data.get(CONF_UNDERLYING_LIST, None) is None:
|
||||
underlying_list = []
|
||||
if thermostat_type == CONF_THERMOSTAT_SWITCH:
|
||||
underlying_list = [
|
||||
config_entry.data.get(CONF_HEATER, None),
|
||||
config_entry.data.get(CONF_HEATER_2, None),
|
||||
config_entry.data.get(CONF_HEATER_3, None),
|
||||
config_entry.data.get(CONF_HEATER_4, None),
|
||||
]
|
||||
elif thermostat_type == CONF_THERMOSTAT_CLIMATE:
|
||||
underlying_list = [
|
||||
config_entry.data.get(CONF_CLIMATE, None),
|
||||
config_entry.data.get(CONF_CLIMATE_2, None),
|
||||
config_entry.data.get(CONF_CLIMATE_3, None),
|
||||
config_entry.data.get(CONF_CLIMATE_4, None),
|
||||
]
|
||||
elif thermostat_type == CONF_THERMOSTAT_VALVE:
|
||||
underlying_list = [
|
||||
config_entry.data.get(CONF_VALVE, None),
|
||||
config_entry.data.get(CONF_VALVE_2, None),
|
||||
config_entry.data.get(CONF_VALVE_3, None),
|
||||
config_entry.data.get(CONF_VALVE_4, None),
|
||||
]
|
||||
|
||||
new[CONF_UNDERLYING_LIST] = [
|
||||
entity for entity in underlying_list if entity is not None
|
||||
]
|
||||
|
||||
for key in [
|
||||
CONF_HEATER,
|
||||
CONF_HEATER_2,
|
||||
CONF_HEATER_3,
|
||||
CONF_HEATER_4,
|
||||
CONF_CLIMATE,
|
||||
CONF_CLIMATE_2,
|
||||
CONF_CLIMATE_3,
|
||||
CONF_CLIMATE_4,
|
||||
CONF_VALVE,
|
||||
CONF_VALVE_2,
|
||||
CONF_VALVE_3,
|
||||
CONF_VALVE_4,
|
||||
]:
|
||||
new.pop(key, None)
|
||||
|
||||
hass.config_entries.async_update_entry(
|
||||
config_entry,
|
||||
data=new,
|
||||
|
||||
@@ -3,7 +3,7 @@
|
||||
"""
|
||||
|
||||
import logging
|
||||
from datetime import datetime, timedelta
|
||||
from datetime import datetime
|
||||
from typing import Literal
|
||||
|
||||
from homeassistant.components.climate import HVACMode
|
||||
@@ -13,7 +13,6 @@ from .const import (
|
||||
AUTO_START_STOP_LEVEL_FAST,
|
||||
AUTO_START_STOP_LEVEL_MEDIUM,
|
||||
AUTO_START_STOP_LEVEL_SLOW,
|
||||
CONF_AUTO_START_STOP_LEVELS,
|
||||
TYPE_AUTO_START_STOP_LEVELS,
|
||||
)
|
||||
|
||||
@@ -31,6 +30,9 @@ DT_MIN = {
|
||||
# the measurement cycle (2 min)
|
||||
CYCLE_SEC = 120
|
||||
|
||||
# A temp hysteresis to avoid rapid OFF/ON
|
||||
TEMP_HYSTERESIS = 0.5
|
||||
|
||||
ERROR_THRESHOLD = {
|
||||
AUTO_START_STOP_LEVEL_NONE: 0, # Not used
|
||||
AUTO_START_STOP_LEVEL_SLOW: 10, # 10 cycle above 1° or 5 cycle above 2°, ...
|
||||
@@ -79,7 +81,7 @@ class AutoStartStopDetectionAlgorithm:
|
||||
saved_hvac_mode: HVACMode | None,
|
||||
target_temp: float,
|
||||
current_temp: float,
|
||||
slope_min: float,
|
||||
slope_min: float | None,
|
||||
now: datetime,
|
||||
) -> AUTO_START_STOP_ACTIONS:
|
||||
"""Calculate an eventual action to do depending of the value in parameter"""
|
||||
@@ -101,12 +103,7 @@ class AutoStartStopDetectionAlgorithm:
|
||||
now,
|
||||
)
|
||||
|
||||
if (
|
||||
hvac_mode is None
|
||||
or target_temp is None
|
||||
or current_temp is None
|
||||
or slope_min is None
|
||||
):
|
||||
if hvac_mode is None or target_temp is None or current_temp is None:
|
||||
_LOGGER.debug(
|
||||
"%s - No all mandatory parameters are set. Disable auto-start/stop",
|
||||
self,
|
||||
@@ -119,8 +116,8 @@ class AutoStartStopDetectionAlgorithm:
|
||||
# reduce the error considering the dt between the last measurement
|
||||
if self._last_calculation_date is not None:
|
||||
dtmin = (now - self._last_calculation_date).total_seconds() / CYCLE_SEC
|
||||
# ignore two calls too near (< 1 min)
|
||||
if dtmin <= 0.5:
|
||||
# ignore two calls too near (< 24 sec)
|
||||
if dtmin <= 0.2:
|
||||
_LOGGER.debug(
|
||||
"%s - new calculation of auto_start_stop (%s) is too near of the last one (%s). Forget it",
|
||||
self,
|
||||
@@ -144,10 +141,15 @@ class AutoStartStopDetectionAlgorithm:
|
||||
|
||||
self._last_calculation_date = now
|
||||
|
||||
temp_at_dt = current_temp + slope_min * self._dt
|
||||
|
||||
# Check to turn-off
|
||||
# When we hit the threshold, that mean we can turn off
|
||||
if hvac_mode == HVACMode.HEAT:
|
||||
if self._accumulated_error <= -self._error_threshold and slope_min >= 0:
|
||||
if (
|
||||
self._accumulated_error <= -self._error_threshold
|
||||
and temp_at_dt >= target_temp + TEMP_HYSTERESIS
|
||||
):
|
||||
_LOGGER.info(
|
||||
"%s - We need to stop, there is no need for heating for a long time.",
|
||||
self,
|
||||
@@ -158,7 +160,10 @@ class AutoStartStopDetectionAlgorithm:
|
||||
return AUTO_START_STOP_ACTION_NOTHING
|
||||
|
||||
if hvac_mode == HVACMode.COOL:
|
||||
if self._accumulated_error >= self._error_threshold and slope_min <= 0:
|
||||
if (
|
||||
self._accumulated_error >= self._error_threshold
|
||||
and temp_at_dt <= target_temp - TEMP_HYSTERESIS
|
||||
):
|
||||
_LOGGER.info(
|
||||
"%s - We need to stop, there is no need for cooling for a long time.",
|
||||
self,
|
||||
@@ -173,7 +178,7 @@ class AutoStartStopDetectionAlgorithm:
|
||||
|
||||
# check to turn on
|
||||
if hvac_mode == HVACMode.OFF and saved_hvac_mode == HVACMode.HEAT:
|
||||
if current_temp + slope_min * self._dt <= target_temp:
|
||||
if temp_at_dt <= target_temp - TEMP_HYSTERESIS:
|
||||
_LOGGER.info(
|
||||
"%s - We need to start, because it will be time to heat",
|
||||
self,
|
||||
@@ -187,7 +192,7 @@ class AutoStartStopDetectionAlgorithm:
|
||||
return AUTO_START_STOP_ACTION_NOTHING
|
||||
|
||||
if hvac_mode == HVACMode.OFF and saved_hvac_mode == HVACMode.COOL:
|
||||
if current_temp + slope_min * self._dt >= target_temp:
|
||||
if temp_at_dt >= target_temp + TEMP_HYSTERESIS:
|
||||
_LOGGER.info(
|
||||
"%s - We need to start, because it will be time to cool",
|
||||
self,
|
||||
|
||||
@@ -19,7 +19,10 @@ from homeassistant.core import (
|
||||
)
|
||||
|
||||
from homeassistant.components.climate import ClimateEntity
|
||||
from homeassistant.helpers.restore_state import RestoreEntity
|
||||
from homeassistant.helpers.restore_state import (
|
||||
RestoreEntity,
|
||||
async_get as restore_async_get,
|
||||
)
|
||||
from homeassistant.helpers.entity import Entity
|
||||
from homeassistant.config_entries import ConfigEntry
|
||||
from homeassistant.helpers.device_registry import DeviceInfo, DeviceEntryType
|
||||
@@ -62,72 +65,7 @@ from homeassistant.const import (
|
||||
STATE_NOT_HOME,
|
||||
)
|
||||
|
||||
from .const import (
|
||||
DOMAIN,
|
||||
DEVICE_MANUFACTURER,
|
||||
CONF_POWER_SENSOR,
|
||||
CONF_TEMP_SENSOR,
|
||||
CONF_LAST_SEEN_TEMP_SENSOR,
|
||||
CONF_EXTERNAL_TEMP_SENSOR,
|
||||
CONF_MAX_POWER_SENSOR,
|
||||
CONF_WINDOW_SENSOR,
|
||||
CONF_WINDOW_DELAY,
|
||||
CONF_WINDOW_AUTO_CLOSE_THRESHOLD,
|
||||
CONF_WINDOW_AUTO_OPEN_THRESHOLD,
|
||||
CONF_WINDOW_AUTO_MAX_DURATION,
|
||||
CONF_MOTION_SENSOR,
|
||||
CONF_MOTION_DELAY,
|
||||
CONF_MOTION_OFF_DELAY,
|
||||
CONF_MOTION_PRESET,
|
||||
CONF_NO_MOTION_PRESET,
|
||||
CONF_DEVICE_POWER,
|
||||
CONF_PRESETS,
|
||||
# CONF_PRESETS_AWAY,
|
||||
# CONF_PRESETS_WITH_AC,
|
||||
# CONF_PRESETS_AWAY_WITH_AC,
|
||||
CONF_CYCLE_MIN,
|
||||
CONF_PROP_FUNCTION,
|
||||
CONF_TPI_COEF_INT,
|
||||
CONF_TPI_COEF_EXT,
|
||||
CONF_PRESENCE_SENSOR,
|
||||
CONF_PRESET_POWER,
|
||||
SUPPORT_FLAGS,
|
||||
PRESET_FROST_PROTECTION,
|
||||
PRESET_POWER,
|
||||
PRESET_SECURITY,
|
||||
PROPORTIONAL_FUNCTION_TPI,
|
||||
PRESET_AWAY_SUFFIX,
|
||||
CONF_SECURITY_DELAY_MIN,
|
||||
CONF_SECURITY_MIN_ON_PERCENT,
|
||||
CONF_SECURITY_DEFAULT_ON_PERCENT,
|
||||
DEFAULT_SECURITY_MIN_ON_PERCENT,
|
||||
DEFAULT_SECURITY_DEFAULT_ON_PERCENT,
|
||||
CONF_MINIMAL_ACTIVATION_DELAY,
|
||||
CONF_USE_MAIN_CENTRAL_CONFIG,
|
||||
CONF_USE_TPI_CENTRAL_CONFIG,
|
||||
CONF_USE_PRESETS_CENTRAL_CONFIG,
|
||||
CONF_USE_WINDOW_CENTRAL_CONFIG,
|
||||
CONF_USE_MOTION_CENTRAL_CONFIG,
|
||||
CONF_USE_POWER_CENTRAL_CONFIG,
|
||||
CONF_USE_PRESENCE_CENTRAL_CONFIG,
|
||||
CONF_USE_ADVANCED_CENTRAL_CONFIG,
|
||||
CONF_USE_PRESENCE_FEATURE,
|
||||
CONF_TEMP_MAX,
|
||||
CONF_TEMP_MIN,
|
||||
HIDDEN_PRESETS,
|
||||
CONF_AC_MODE,
|
||||
EventType,
|
||||
ATTR_MEAN_POWER_CYCLE,
|
||||
ATTR_TOTAL_ENERGY,
|
||||
PRESET_AC_SUFFIX,
|
||||
DEFAULT_SHORT_EMA_PARAMS,
|
||||
CENTRAL_MODE_AUTO,
|
||||
CENTRAL_MODE_STOPPED,
|
||||
CENTRAL_MODE_HEAT_ONLY,
|
||||
CENTRAL_MODE_COOL_ONLY,
|
||||
CENTRAL_MODE_FROST_PROTECTION,
|
||||
send_vtherm_event,
|
||||
)
|
||||
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
|
||||
|
||||
from .config_schema import * # pylint: disable=wildcard-import, unused-wildcard-import
|
||||
|
||||
@@ -149,6 +87,10 @@ def get_tz(hass: HomeAssistant):
|
||||
return dt_util.get_time_zone(hass.config.time_zone)
|
||||
|
||||
|
||||
_LOGGER_ENERGY = logging.getLogger(
|
||||
"custom_components.versatile_thermostat.energy_debug"
|
||||
)
|
||||
|
||||
class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"""Representation of a base class for all Versatile Thermostat device."""
|
||||
|
||||
@@ -199,6 +141,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"is_device_active",
|
||||
"target_temperature_step",
|
||||
"is_used_by_central_boiler",
|
||||
"temperature_slope"
|
||||
}
|
||||
)
|
||||
)
|
||||
@@ -262,6 +205,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
self._attr_translation_key = "versatile_thermostat"
|
||||
|
||||
self._total_energy = None
|
||||
_LOGGER_ENERGY.debug("%s - _init_ resetting energy to None", self)
|
||||
|
||||
# because energy of climate is calculated in the thermostat we have to keep that here and not in underlying entity
|
||||
self._underlying_climate_start_hvac_action_date = None
|
||||
@@ -303,6 +247,8 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
|
||||
self._use_central_config_temperature = False
|
||||
|
||||
self._hvac_off_reason: HVAC_OFF_REASONS | None = None
|
||||
|
||||
self.post_init(entry_infos)
|
||||
|
||||
def clean_central_config_doublon(
|
||||
@@ -532,6 +478,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
self._presence_state = None
|
||||
|
||||
self._total_energy = None
|
||||
_LOGGER_ENERGY.debug("%s - post_init_ resetting energy to None", self)
|
||||
|
||||
# Read the parameter from configuration.yaml if it exists
|
||||
short_ema_params = DEFAULT_SHORT_EMA_PARAMS
|
||||
@@ -647,14 +594,24 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
# issue 428. Link to others entities will start at link
|
||||
# await self.async_startup()
|
||||
|
||||
async def async_will_remove_from_hass(self):
|
||||
"""Try to force backup of entity"""
|
||||
_LOGGER_ENERGY.debug(
|
||||
"%s - force write before remove. Energy is %s", self, self.total_energy
|
||||
)
|
||||
# Force dump in background
|
||||
await restore_async_get(self.hass).async_dump_states()
|
||||
|
||||
def remove_thermostat(self):
|
||||
"""Called when the thermostat will be removed"""
|
||||
_LOGGER.info("%s - Removing thermostat", self)
|
||||
|
||||
for under in self._underlyings:
|
||||
under.remove_entity()
|
||||
|
||||
async def async_startup(self, central_configuration):
|
||||
"""Triggered on startup, used to get old state and set internal states accordingly"""
|
||||
"""Triggered on startup, used to get old state and set internal states accordingly. This is triggered by
|
||||
VTherm API"""
|
||||
_LOGGER.debug("%s - Calling async_startup", self)
|
||||
|
||||
_LOGGER.debug("%s - Calling async_startup_internal", self)
|
||||
@@ -848,18 +805,29 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
else:
|
||||
self._attr_preset_mode = PRESET_NONE
|
||||
|
||||
# Restore old hvac_off_reason
|
||||
self._hvac_off_reason = old_state.attributes.get(HVAC_OFF_REASON_NAME, None)
|
||||
|
||||
if old_state.state in [
|
||||
HVACMode.OFF,
|
||||
HVACMode.HEAT,
|
||||
HVACMode.COOL,
|
||||
]:
|
||||
self._hvac_mode = old_state.state
|
||||
else:
|
||||
if not self._hvac_mode:
|
||||
self._hvac_mode = HVACMode.OFF
|
||||
|
||||
# restpre also saved info so that window detection will work
|
||||
self._saved_hvac_mode = old_state.attributes.get("saved_hvac_mode", None)
|
||||
self._saved_preset_mode = old_state.attributes.get(
|
||||
"saved_preset_mode", None
|
||||
)
|
||||
|
||||
old_total_energy = old_state.attributes.get(ATTR_TOTAL_ENERGY)
|
||||
self._total_energy = old_total_energy if old_total_energy else 0
|
||||
self._total_energy = old_total_energy if old_total_energy is not None else 0
|
||||
_LOGGER_ENERGY.debug(
|
||||
"%s - get_my_previous_state restored energy is %s",
|
||||
self,
|
||||
self._total_energy,
|
||||
)
|
||||
|
||||
self.restore_specific_previous_state(old_state)
|
||||
else:
|
||||
@@ -873,13 +841,20 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"No previously saved temperature, setting to %s", self._target_temp
|
||||
)
|
||||
self._total_energy = 0
|
||||
_LOGGER_ENERGY.debug(
|
||||
"%s - get_my_previous_state no previous state energy is %s",
|
||||
self,
|
||||
self._total_energy,
|
||||
)
|
||||
|
||||
self._saved_target_temp = self._target_temp
|
||||
|
||||
# Set default state to off
|
||||
if not self._hvac_mode:
|
||||
self._hvac_mode = HVACMode.OFF
|
||||
|
||||
if not self.is_on and self.hvac_off_reason is None:
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_MANUAL)
|
||||
|
||||
self._saved_target_temp = self._target_temp
|
||||
|
||||
self.send_event(EventType.PRESET_EVENT, {"preset": self._attr_preset_mode})
|
||||
self.send_event(EventType.HVAC_MODE_EVENT, {"hvac_mode": self._hvac_mode})
|
||||
|
||||
@@ -987,16 +962,6 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
@property
|
||||
def hvac_mode(self) -> HVACMode | None:
|
||||
"""Return current operation."""
|
||||
# Issue #114 - returns my current hvac_mode and not the underlying hvac_mode which could be different
|
||||
# delta will be managed by climate_state_change event.
|
||||
# if self.is_over_climate:
|
||||
# if one not OFF -> return it
|
||||
# else OFF
|
||||
# for under in self._underlyings:
|
||||
# if (mode := under.hvac_mode) not in [HVACMode.OFF]
|
||||
# return mode
|
||||
# return HVACMode.OFF
|
||||
|
||||
return self._hvac_mode
|
||||
|
||||
@property
|
||||
@@ -1193,6 +1158,13 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"""True if this VTHerm uses the central configuration temperature"""
|
||||
return self._use_central_config_temperature
|
||||
|
||||
@property
|
||||
def hvac_off_reason(self) -> HVAC_OFF_REASONS:
|
||||
"""Returns the reason of the last switch to HVAC_OFF
|
||||
This is useful for features that turns off the VTherm like
|
||||
window detection or auto-start-stop"""
|
||||
return self._hvac_off_reason
|
||||
|
||||
def underlying_entity_id(self, index=0) -> str | None:
|
||||
"""The climate_entity_id. Added for retrocompatibility reason"""
|
||||
if index < self.nb_underlying_entities:
|
||||
@@ -1234,6 +1206,24 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
if hvac_mode is None:
|
||||
return
|
||||
|
||||
def save_state():
|
||||
self.reset_last_change_time()
|
||||
self.update_custom_attributes()
|
||||
self.async_write_ha_state()
|
||||
self.send_event(EventType.HVAC_MODE_EVENT, {"hvac_mode": self._hvac_mode})
|
||||
|
||||
# If we already are in OFF, the manual OFF should just overwrite the reason and saved_hvac_mode
|
||||
if self._hvac_mode == HVACMode.OFF and hvac_mode == HVACMode.OFF:
|
||||
_LOGGER.info(
|
||||
"%s - already in OFF. Change the reason to MANUAL and erase the saved_havc_mode"
|
||||
)
|
||||
self._hvac_off_reason = HVAC_OFF_REASON_MANUAL
|
||||
self._saved_hvac_mode = HVACMode.OFF
|
||||
|
||||
save_state()
|
||||
|
||||
return
|
||||
|
||||
self._hvac_mode = hvac_mode
|
||||
|
||||
# Delegate to all underlying
|
||||
@@ -1256,11 +1246,10 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
# Ensure we update the current operation after changing the mode
|
||||
self.reset_last_temperature_time()
|
||||
|
||||
self.reset_last_change_time()
|
||||
if self._hvac_mode != HVACMode.OFF:
|
||||
self.set_hvac_off_reason(None)
|
||||
|
||||
self.update_custom_attributes()
|
||||
self.async_write_ha_state()
|
||||
self.send_event(EventType.HVAC_MODE_EVENT, {"hvac_mode": self._hvac_mode})
|
||||
save_state()
|
||||
|
||||
@overrides
|
||||
async def async_set_preset_mode(
|
||||
@@ -1760,6 +1749,19 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
for under in self._underlyings:
|
||||
await under.check_initial_state(self._hvac_mode)
|
||||
|
||||
# Prevent from starting a VTherm if window is open
|
||||
if (
|
||||
self.is_window_auto_enabled
|
||||
and self._window_sensor_entity_id is not None
|
||||
and self._hass.states.is_state(self._window_sensor_entity_id, STATE_ON)
|
||||
and self.is_on
|
||||
and self.window_action == CONF_WINDOW_TURN_OFF
|
||||
):
|
||||
_LOGGER.info("%s - the window is open. Prevent starting the VTherm")
|
||||
self._window_auto_state = True
|
||||
self.save_hvac_mode()
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
|
||||
# Starts the initial control loop (don't wait for an update of temperature)
|
||||
await self.async_control_heating(force=True)
|
||||
|
||||
@@ -2096,6 +2098,10 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
self._hvac_mode,
|
||||
)
|
||||
|
||||
def set_hvac_off_reason(self, hvac_off_reason: HVAC_OFF_REASONS):
|
||||
"""Set the reason of hvac_off"""
|
||||
self._hvac_off_reason = hvac_off_reason
|
||||
|
||||
async def restore_hvac_mode(self, need_control_heating=False):
|
||||
"""Restore a previous hvac_mod"""
|
||||
await self.async_set_hvac_mode(self._saved_hvac_mode, need_control_heating)
|
||||
@@ -2227,27 +2233,34 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
if self.window_state is not STATE_ON and not first_init:
|
||||
await self.restore_hvac_mode()
|
||||
await self.restore_preset_mode()
|
||||
|
||||
elif self.window_state is STATE_ON and self.hvac_mode == HVACMode.OFF:
|
||||
# do not restore but mark the reason of off with window detection
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_WINDOW_DETECTION)
|
||||
return
|
||||
|
||||
if old_central_mode == CENTRAL_MODE_AUTO and self.window_state is not STATE_ON:
|
||||
save_all()
|
||||
|
||||
if new_central_mode == CENTRAL_MODE_STOPPED:
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
if self.hvac_mode != HVACMode.OFF:
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_MANUAL)
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
return
|
||||
|
||||
if new_central_mode == CENTRAL_MODE_COOL_ONLY:
|
||||
if HVACMode.COOL in self.hvac_modes:
|
||||
await self.async_set_hvac_mode(HVACMode.COOL)
|
||||
else:
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_MANUAL)
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
return
|
||||
|
||||
if new_central_mode == CENTRAL_MODE_HEAT_ONLY:
|
||||
if HVACMode.HEAT in self.hvac_modes:
|
||||
await self.async_set_hvac_mode(HVACMode.HEAT)
|
||||
else:
|
||||
# if not already off
|
||||
elif self.hvac_mode != HVACMode.OFF:
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_MANUAL)
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
return
|
||||
|
||||
@@ -2261,6 +2274,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
PRESET_FROST_PROTECTION, overwrite_saved_preset=False
|
||||
)
|
||||
else:
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_MANUAL)
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
return
|
||||
|
||||
@@ -2440,17 +2454,27 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"""Change the window detection state.
|
||||
new_state is on if an open window have been detected or off else
|
||||
"""
|
||||
if not new_state:
|
||||
if new_state is False:
|
||||
_LOGGER.info(
|
||||
"%s - Window is closed. Restoring hvac_mode '%s' if central_mode is not STOPPED",
|
||||
"%s - Window is closed. Restoring hvac_mode '%s' if stopped by window detection or temperature %s",
|
||||
self,
|
||||
self._saved_hvac_mode,
|
||||
self._saved_target_temp,
|
||||
)
|
||||
if self._window_action in [CONF_WINDOW_FROST_TEMP, CONF_WINDOW_ECO_TEMP]:
|
||||
await self._async_internal_set_temperature(self._saved_target_temp)
|
||||
|
||||
# default to TURN_OFF
|
||||
elif self._window_action in [CONF_WINDOW_TURN_OFF, CONF_WINDOW_FAN_ONLY]:
|
||||
elif self._window_action in [CONF_WINDOW_TURN_OFF]:
|
||||
if (
|
||||
self.last_central_mode != CENTRAL_MODE_STOPPED
|
||||
and self.hvac_off_reason == HVAC_OFF_REASON_WINDOW_DETECTION
|
||||
):
|
||||
self.set_hvac_off_reason(None)
|
||||
await self.restore_hvac_mode(True)
|
||||
elif self._window_action in [CONF_WINDOW_FAN_ONLY]:
|
||||
if self.last_central_mode != CENTRAL_MODE_STOPPED:
|
||||
self.set_hvac_off_reason(None)
|
||||
await self.restore_hvac_mode(True)
|
||||
else:
|
||||
_LOGGER.error(
|
||||
@@ -2462,6 +2486,12 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
_LOGGER.info(
|
||||
"%s - Window is open. Set hvac_mode to '%s'", self, HVACMode.OFF
|
||||
)
|
||||
if self._window_action == CONF_WINDOW_TURN_OFF and not self.is_on:
|
||||
_LOGGER.debug(
|
||||
"%s is already off. Forget turning off VTherm due to window detection"
|
||||
)
|
||||
return
|
||||
|
||||
if self.last_central_mode in [CENTRAL_MODE_AUTO, None]:
|
||||
if self._window_action in [CONF_WINDOW_TURN_OFF, CONF_WINDOW_FAN_ONLY]:
|
||||
self.save_hvac_mode()
|
||||
@@ -2491,6 +2521,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
self.find_preset_temp(PRESET_ECO)
|
||||
)
|
||||
else: # default is to turn_off
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_WINDOW_DETECTION)
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
|
||||
async def async_control_heating(self, force=False, _=None) -> bool:
|
||||
@@ -2633,8 +2664,26 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"is_device_active": self.is_device_active,
|
||||
"ema_temp": self._ema_temp,
|
||||
"is_used_by_central_boiler": self.is_used_by_central_boiler,
|
||||
"temperature_slope": round(self.last_temperature_slope or 0, 3),
|
||||
"hvac_off_reason": self.hvac_off_reason,
|
||||
}
|
||||
|
||||
_LOGGER_ENERGY.debug(
|
||||
"%s - update_custom_attributes saved energy is %s",
|
||||
self,
|
||||
self.total_energy,
|
||||
)
|
||||
|
||||
@overrides
|
||||
def async_write_ha_state(self):
|
||||
"""overrides to have log"""
|
||||
_LOGGER_ENERGY.debug(
|
||||
"%s - async_write_ha_state written state energy is %s",
|
||||
self,
|
||||
self._total_energy,
|
||||
)
|
||||
return super().async_write_ha_state()
|
||||
|
||||
@callback
|
||||
def async_registry_entry_updated(self):
|
||||
"""update the entity if the config entry have been updated
|
||||
|
||||
@@ -17,7 +17,6 @@ from .const import DOMAIN, DEVICE_MANUFACTURER, ServiceConfigurationError
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
|
||||
def get_tz(hass: HomeAssistant):
|
||||
"""Get the current timezone"""
|
||||
|
||||
|
||||
@@ -109,17 +109,17 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
or self._infos.get(CONF_WINDOW_AUTO_OPEN_THRESHOLD) is not None
|
||||
)
|
||||
self._infos[CONF_USE_MOTION_FEATURE] = self._infos.get(
|
||||
CONF_USE_MOTION_FEATURE
|
||||
CONF_USE_MOTION_FEATURE, False
|
||||
) and (self._infos.get(CONF_MOTION_SENSOR) is not None or is_central_config)
|
||||
|
||||
self._infos[CONF_USE_POWER_FEATURE] = self._infos.get(
|
||||
CONF_USE_POWER_CENTRAL_CONFIG
|
||||
CONF_USE_POWER_CENTRAL_CONFIG, False
|
||||
) or (
|
||||
self._infos.get(CONF_POWER_SENSOR) is not None
|
||||
and self._infos.get(CONF_MAX_POWER_SENSOR) is not None
|
||||
)
|
||||
self._infos[CONF_USE_PRESENCE_FEATURE] = (
|
||||
self._infos.get(CONF_USE_PRESENCE_CENTRAL_CONFIG)
|
||||
self._infos.get(CONF_USE_PRESENCE_CENTRAL_CONFIG, False)
|
||||
or self._infos.get(CONF_PRESENCE_SENSOR) is not None
|
||||
)
|
||||
|
||||
@@ -129,7 +129,7 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
)
|
||||
|
||||
self._infos[CONF_USE_AUTO_START_STOP_FEATURE] = (
|
||||
self._infos.get(CONF_USE_AUTO_START_STOP_FEATURE) is True
|
||||
self._infos.get(CONF_USE_AUTO_START_STOP_FEATURE, False) is True
|
||||
and self._infos.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_CLIMATE
|
||||
)
|
||||
|
||||
@@ -145,12 +145,17 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
CONF_USE_PRESETS_CENTRAL_CONFIG,
|
||||
CONF_USE_PRESENCE_CENTRAL_CONFIG,
|
||||
CONF_USE_ADVANCED_CENTRAL_CONFIG,
|
||||
CONF_USE_CENTRAL_MODE,
|
||||
):
|
||||
if not is_empty:
|
||||
current_config = self._infos.get(config, None)
|
||||
self._infos[config] = current_config is True or (
|
||||
current_config is None and self._central_config is not None
|
||||
|
||||
self._infos[config] = self._central_config is not None and (
|
||||
current_config is True or current_config is None
|
||||
)
|
||||
# self._infos[config] = current_config is True or (
|
||||
# current_config is None and self._central_config is not None
|
||||
# )
|
||||
else:
|
||||
self._infos[config] = self._central_config is not None
|
||||
|
||||
@@ -165,7 +170,7 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
|
||||
# check the heater_entity_id
|
||||
for conf in [
|
||||
CONF_HEATER,
|
||||
CONF_UNDERLYING_LIST,
|
||||
CONF_TEMP_SENSOR,
|
||||
CONF_EXTERNAL_TEMP_SENSOR,
|
||||
CONF_WINDOW_SENSOR,
|
||||
@@ -173,15 +178,17 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
CONF_POWER_SENSOR,
|
||||
CONF_MAX_POWER_SENSOR,
|
||||
CONF_PRESENCE_SENSOR,
|
||||
CONF_CLIMATE,
|
||||
]:
|
||||
d = data.get(conf, None) # pylint: disable=invalid-name
|
||||
if d is not None and self.hass.states.get(d) is None:
|
||||
_LOGGER.error(
|
||||
"Entity id %s doesn't have any state. We cannot use it in the Versatile Thermostat configuration", # pylint: disable=line-too-long
|
||||
d,
|
||||
)
|
||||
raise UnknownEntity(conf)
|
||||
if not isinstance(d, list):
|
||||
d = [d]
|
||||
for e in d:
|
||||
if e is not None and self.hass.states.get(e) is None:
|
||||
_LOGGER.error(
|
||||
"Entity id %s doesn't have any state. We cannot use it in the Versatile Thermostat configuration", # pylint: disable=line-too-long
|
||||
e,
|
||||
)
|
||||
raise UnknownEntity(conf)
|
||||
|
||||
# Check that only one window feature is used
|
||||
ws = self._infos.get(CONF_WINDOW_SENSOR) # pylint: disable=invalid-name
|
||||
@@ -207,6 +214,9 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
CONF_USE_PRESENCE_CENTRAL_CONFIG,
|
||||
CONF_USE_PRESETS_CENTRAL_CONFIG,
|
||||
CONF_USE_ADVANCED_CENTRAL_CONFIG,
|
||||
CONF_USE_CENTRAL_MODE,
|
||||
# CONF_USE_CENTRAL_BOILER_FEATURE, this is for Central Config
|
||||
CONF_USED_BY_CENTRAL_BOILER,
|
||||
]:
|
||||
if data.get(conf) is True:
|
||||
_LOGGER.error(
|
||||
@@ -270,21 +280,8 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
):
|
||||
return False
|
||||
|
||||
if (
|
||||
infos.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_SWITCH
|
||||
and infos.get(CONF_HEATER, None) is None
|
||||
):
|
||||
return False
|
||||
|
||||
if (
|
||||
infos.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_CLIMATE
|
||||
and infos.get(CONF_CLIMATE, None) is None
|
||||
):
|
||||
return False
|
||||
|
||||
if (
|
||||
infos.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_VALVE
|
||||
and infos.get(CONF_VALVE, None) is None
|
||||
if infos.get(CONF_UNDERLYING_LIST, None) is not None and not infos.get(
|
||||
CONF_UNDERLYING_LIST, None
|
||||
):
|
||||
return False
|
||||
|
||||
@@ -317,6 +314,22 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
):
|
||||
return False
|
||||
|
||||
if (
|
||||
infos.get(CONF_PROP_FUNCTION, None) == PROPORTIONAL_FUNCTION_TPI
|
||||
and infos.get(CONF_USE_TPI_CENTRAL_CONFIG, False) is False
|
||||
and (
|
||||
infos.get(CONF_TPI_COEF_INT, None) is None
|
||||
or infos.get(CONF_TPI_COEF_EXT) is None
|
||||
)
|
||||
):
|
||||
return False
|
||||
|
||||
if (
|
||||
infos.get(CONF_USE_PRESETS_CENTRAL_CONFIG, False) is True
|
||||
and self._central_config is None
|
||||
):
|
||||
return False
|
||||
|
||||
return True
|
||||
|
||||
def merge_user_input(self, data_schema: vol.Schema, user_input: dict):
|
||||
|
||||
@@ -119,17 +119,10 @@ STEP_CENTRAL_BOILER_SCHEMA = vol.Schema(
|
||||
|
||||
STEP_THERMOSTAT_SWITCH = vol.Schema( # pylint: disable=invalid-name
|
||||
{
|
||||
vol.Required(CONF_HEATER): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=[SWITCH_DOMAIN, INPUT_BOOLEAN_DOMAIN]),
|
||||
),
|
||||
vol.Optional(CONF_HEATER_2): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=[SWITCH_DOMAIN, INPUT_BOOLEAN_DOMAIN]),
|
||||
),
|
||||
vol.Optional(CONF_HEATER_3): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=[SWITCH_DOMAIN, INPUT_BOOLEAN_DOMAIN]),
|
||||
),
|
||||
vol.Optional(CONF_HEATER_4): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=[SWITCH_DOMAIN, INPUT_BOOLEAN_DOMAIN]),
|
||||
vol.Required(CONF_UNDERLYING_LIST): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(
|
||||
domain=[SWITCH_DOMAIN, INPUT_BOOLEAN_DOMAIN], multiple=True
|
||||
),
|
||||
),
|
||||
vol.Optional(CONF_HEATER_KEEP_ALIVE): cv.positive_int,
|
||||
vol.Required(CONF_PROP_FUNCTION, default=PROPORTIONAL_FUNCTION_TPI): vol.In(
|
||||
@@ -144,17 +137,8 @@ STEP_THERMOSTAT_SWITCH = vol.Schema( # pylint: disable=invalid-name
|
||||
|
||||
STEP_THERMOSTAT_CLIMATE = vol.Schema( # pylint: disable=invalid-name
|
||||
{
|
||||
vol.Required(CONF_CLIMATE): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=CLIMATE_DOMAIN),
|
||||
),
|
||||
vol.Optional(CONF_CLIMATE_2): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=CLIMATE_DOMAIN),
|
||||
),
|
||||
vol.Optional(CONF_CLIMATE_3): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=CLIMATE_DOMAIN),
|
||||
),
|
||||
vol.Optional(CONF_CLIMATE_4): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=CLIMATE_DOMAIN),
|
||||
vol.Required(CONF_UNDERLYING_LIST): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=CLIMATE_DOMAIN, multiple=True),
|
||||
),
|
||||
vol.Optional(CONF_AC_MODE, default=False): cv.boolean,
|
||||
vol.Optional(
|
||||
@@ -183,17 +167,10 @@ STEP_THERMOSTAT_CLIMATE = vol.Schema( # pylint: disable=invalid-name
|
||||
|
||||
STEP_THERMOSTAT_VALVE = vol.Schema( # pylint: disable=invalid-name
|
||||
{
|
||||
vol.Required(CONF_VALVE): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=[NUMBER_DOMAIN, INPUT_NUMBER_DOMAIN]),
|
||||
),
|
||||
vol.Optional(CONF_VALVE_2): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=[NUMBER_DOMAIN, INPUT_NUMBER_DOMAIN]),
|
||||
),
|
||||
vol.Optional(CONF_VALVE_3): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=[NUMBER_DOMAIN, INPUT_NUMBER_DOMAIN]),
|
||||
),
|
||||
vol.Optional(CONF_VALVE_4): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=[NUMBER_DOMAIN, INPUT_NUMBER_DOMAIN]),
|
||||
vol.Required(CONF_UNDERLYING_LIST): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(
|
||||
domain=[NUMBER_DOMAIN, INPUT_NUMBER_DOMAIN], multiple=True
|
||||
),
|
||||
),
|
||||
vol.Required(CONF_PROP_FUNCTION, default=PROPORTIONAL_FUNCTION_TPI): vol.In(
|
||||
[
|
||||
|
||||
@@ -23,8 +23,8 @@ from .prop_algorithm import (
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
CONFIG_VERSION = 1
|
||||
CONFIG_MINOR_VERSION = 2
|
||||
CONFIG_VERSION = 2
|
||||
CONFIG_MINOR_VERSION = 0
|
||||
|
||||
PRESET_TEMP_SUFFIX = "_temp"
|
||||
PRESET_AC_SUFFIX = "_ac"
|
||||
@@ -55,10 +55,7 @@ PLATFORMS: list[Platform] = [
|
||||
Platform.SWITCH,
|
||||
]
|
||||
|
||||
CONF_HEATER = "heater_entity_id"
|
||||
CONF_HEATER_2 = "heater_entity2_id"
|
||||
CONF_HEATER_3 = "heater_entity3_id"
|
||||
CONF_HEATER_4 = "heater_entity4_id"
|
||||
CONF_UNDERLYING_LIST = "underlying_entity_ids"
|
||||
CONF_HEATER_KEEP_ALIVE = "heater_keep_alive"
|
||||
CONF_TEMP_SENSOR = "temperature_sensor_entity_id"
|
||||
CONF_LAST_SEEN_TEMP_SENSOR = "last_seen_temperature_sensor_entity_id"
|
||||
@@ -90,10 +87,6 @@ CONF_THERMOSTAT_CENTRAL_CONFIG = "thermostat_central_config"
|
||||
CONF_THERMOSTAT_SWITCH = "thermostat_over_switch"
|
||||
CONF_THERMOSTAT_CLIMATE = "thermostat_over_climate"
|
||||
CONF_THERMOSTAT_VALVE = "thermostat_over_valve"
|
||||
CONF_CLIMATE = "climate_entity_id"
|
||||
CONF_CLIMATE_2 = "climate_entity2_id"
|
||||
CONF_CLIMATE_3 = "climate_entity3_id"
|
||||
CONF_CLIMATE_4 = "climate_entity4_id"
|
||||
CONF_USE_WINDOW_FEATURE = "use_window_feature"
|
||||
CONF_USE_MOTION_FEATURE = "use_motion_feature"
|
||||
CONF_USE_PRESENCE_FEATURE = "use_presence_feature"
|
||||
@@ -104,10 +97,6 @@ CONF_AC_MODE = "ac_mode"
|
||||
CONF_WINDOW_AUTO_OPEN_THRESHOLD = "window_auto_open_threshold"
|
||||
CONF_WINDOW_AUTO_CLOSE_THRESHOLD = "window_auto_close_threshold"
|
||||
CONF_WINDOW_AUTO_MAX_DURATION = "window_auto_max_duration"
|
||||
CONF_VALVE = "valve_entity_id"
|
||||
CONF_VALVE_2 = "valve_entity2_id"
|
||||
CONF_VALVE_3 = "valve_entity3_id"
|
||||
CONF_VALVE_4 = "valve_entity4_id"
|
||||
CONF_AUTO_REGULATION_MODE = "auto_regulation_mode"
|
||||
CONF_AUTO_REGULATION_NONE = "auto_regulation_none"
|
||||
CONF_AUTO_REGULATION_SLOW = "auto_regulation_slow"
|
||||
@@ -127,6 +116,20 @@ CONF_AUTO_FAN_HIGH = "auto_fan_high"
|
||||
CONF_AUTO_FAN_TURBO = "auto_fan_turbo"
|
||||
CONF_STEP_TEMPERATURE = "step_temperature"
|
||||
|
||||
# Deprecated
|
||||
CONF_HEATER = "heater_entity_id"
|
||||
CONF_HEATER_2 = "heater_entity2_id"
|
||||
CONF_HEATER_3 = "heater_entity3_id"
|
||||
CONF_HEATER_4 = "heater_entity4_id"
|
||||
CONF_CLIMATE = "climate_entity_id"
|
||||
CONF_CLIMATE_2 = "climate_entity2_id"
|
||||
CONF_CLIMATE_3 = "climate_entity3_id"
|
||||
CONF_CLIMATE_4 = "climate_entity4_id"
|
||||
CONF_VALVE = "valve_entity_id"
|
||||
CONF_VALVE_2 = "valve_entity2_id"
|
||||
CONF_VALVE_3 = "valve_entity3_id"
|
||||
CONF_VALVE_4 = "valve_entity4_id"
|
||||
|
||||
# Global params into configuration.yaml
|
||||
CONF_SHORT_EMA_PARAMS = "short_ema_params"
|
||||
CONF_SAFETY_MODE = "safety_mode"
|
||||
@@ -168,6 +171,16 @@ TYPE_AUTO_START_STOP_LEVELS = Literal[ # pylint: disable=invalid-name
|
||||
AUTO_START_STOP_LEVEL_NONE,
|
||||
]
|
||||
|
||||
HVAC_OFF_REASON_NAME = "hvac_off_reason"
|
||||
HVAC_OFF_REASON_MANUAL = "manual"
|
||||
HVAC_OFF_REASON_AUTO_START_STOP = "auto_start_stop"
|
||||
HVAC_OFF_REASON_WINDOW_DETECTION = "window_detection"
|
||||
HVAC_OFF_REASONS = Literal[ # pylint: disable=invalid-name
|
||||
HVAC_OFF_REASON_MANUAL,
|
||||
HVAC_OFF_REASON_AUTO_START_STOP,
|
||||
HVAC_OFF_REASON_WINDOW_DETECTION,
|
||||
]
|
||||
|
||||
DEFAULT_SHORT_EMA_PARAMS = {
|
||||
"max_alpha": 0.5,
|
||||
# In sec
|
||||
@@ -239,10 +252,6 @@ CONF_PRESETS_AWAY_WITH_AC_VALUES = list(CONF_PRESETS_AWAY_WITH_AC.values())
|
||||
ALL_CONF = (
|
||||
[
|
||||
CONF_NAME,
|
||||
CONF_HEATER,
|
||||
CONF_HEATER_2,
|
||||
CONF_HEATER_3,
|
||||
CONF_HEATER_4,
|
||||
CONF_HEATER_KEEP_ALIVE,
|
||||
CONF_TEMP_SENSOR,
|
||||
CONF_EXTERNAL_TEMP_SENSOR,
|
||||
@@ -272,20 +281,12 @@ ALL_CONF = (
|
||||
CONF_THERMOSTAT_TYPE,
|
||||
CONF_THERMOSTAT_SWITCH,
|
||||
CONF_THERMOSTAT_CLIMATE,
|
||||
CONF_CLIMATE,
|
||||
CONF_CLIMATE_2,
|
||||
CONF_CLIMATE_3,
|
||||
CONF_CLIMATE_4,
|
||||
CONF_USE_WINDOW_FEATURE,
|
||||
CONF_USE_MOTION_FEATURE,
|
||||
CONF_USE_PRESENCE_FEATURE,
|
||||
CONF_USE_POWER_FEATURE,
|
||||
CONF_USE_CENTRAL_BOILER_FEATURE,
|
||||
CONF_AC_MODE,
|
||||
CONF_VALVE,
|
||||
CONF_VALVE_2,
|
||||
CONF_VALVE_3,
|
||||
CONF_VALVE_4,
|
||||
CONF_AUTO_REGULATION_MODE,
|
||||
CONF_AUTO_REGULATION_DTEMP,
|
||||
CONF_AUTO_REGULATION_PERIOD_MIN,
|
||||
@@ -353,7 +354,11 @@ CONF_WINDOW_ACTIONS = [
|
||||
CONF_WINDOW_ECO_TEMP,
|
||||
]
|
||||
|
||||
SUPPORT_FLAGS = ClimateEntityFeature.TARGET_TEMPERATURE | ClimateEntityFeature.TURN_OFF | ClimateEntityFeature.TURN_ON
|
||||
SUPPORT_FLAGS = (
|
||||
ClimateEntityFeature.TARGET_TEMPERATURE
|
||||
| ClimateEntityFeature.TURN_OFF
|
||||
| ClimateEntityFeature.TURN_ON
|
||||
)
|
||||
|
||||
SERVICE_SET_PRESENCE = "set_presence"
|
||||
SERVICE_SET_PRESET_TEMPERATURE = "set_preset_temperature"
|
||||
|
||||
18
custom_components/versatile_thermostat/icons.json
Normal file
18
custom_components/versatile_thermostat/icons.json
Normal file
@@ -0,0 +1,18 @@
|
||||
{
|
||||
"entity": {
|
||||
"climate": {
|
||||
"versatile_thermostat": {
|
||||
"state_attributes": {
|
||||
"preset_mode": {
|
||||
"state": {
|
||||
"shedding": "mdi:power-plug-off",
|
||||
"safety": "mdi:shield-alert",
|
||||
"none": "mdi:knob",
|
||||
"frost": "mdi:snowflake"
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -14,6 +14,6 @@
|
||||
"quality_scale": "silver",
|
||||
"requirements": [],
|
||||
"ssdp": [],
|
||||
"version": "6.5.0",
|
||||
"version": "6.6.0",
|
||||
"zeroconf": []
|
||||
}
|
||||
@@ -72,21 +72,10 @@
|
||||
"title": "Linked entities",
|
||||
"description": "Linked entities attributes",
|
||||
"data": {
|
||||
"heater_entity_id": "1st heater switch",
|
||||
"heater_entity2_id": "2nd heater switch",
|
||||
"heater_entity3_id": "3rd heater switch",
|
||||
"heater_entity4_id": "4th heater switch",
|
||||
"underlying_entity_ids": "The device(s) to be controlled",
|
||||
"heater_keep_alive": "Switch keep-alive interval in seconds",
|
||||
"proportional_function": "Algorithm",
|
||||
"climate_entity_id": "1st underlying climate",
|
||||
"climate_entity2_id": "2nd underlying climate",
|
||||
"climate_entity3_id": "3rd underlying climate",
|
||||
"climate_entity4_id": "4th underlying climate",
|
||||
"ac_mode": "AC mode",
|
||||
"valve_entity_id": "1st valve number",
|
||||
"valve_entity2_id": "2nd valve number",
|
||||
"valve_entity3_id": "3rd valve number",
|
||||
"valve_entity4_id": "4th valve number",
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimum period",
|
||||
@@ -95,21 +84,10 @@
|
||||
"auto_fan_mode": "Auto fan mode"
|
||||
},
|
||||
"data_description": {
|
||||
"heater_entity_id": "Mandatory heater entity id",
|
||||
"heater_entity2_id": "Optional 2nd Heater entity id. Leave empty if not required",
|
||||
"heater_entity3_id": "Optional 3rd Heater entity id. Leave empty if not required",
|
||||
"heater_entity4_id": "Optional 4th Heater entity id. Leave empty if not required",
|
||||
"underlying_entity_ids": "The device(s) to be controlled - 1 is required",
|
||||
"heater_keep_alive": "Optional heater switch state refresh interval. Leave empty if not required.",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"climate_entity_id": "Underlying climate entity id",
|
||||
"climate_entity2_id": "2nd underlying climate entity id",
|
||||
"climate_entity3_id": "3rd underlying climate entity id",
|
||||
"climate_entity4_id": "4th underlying climate entity id",
|
||||
"ac_mode": "Use the Air Conditioning (AC) mode",
|
||||
"valve_entity_id": "1st valve number entity id",
|
||||
"valve_entity2_id": "2nd valve number entity id",
|
||||
"valve_entity3_id": "3rd valve number entity id",
|
||||
"valve_entity4_id": "4th valve number entity id",
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
@@ -309,21 +287,10 @@
|
||||
"title": "Entities - {name}",
|
||||
"description": "Linked entities attributes",
|
||||
"data": {
|
||||
"heater_entity_id": "1st heater switch",
|
||||
"heater_entity2_id": "2nd heater switch",
|
||||
"heater_entity3_id": "3rd heater switch",
|
||||
"heater_entity4_id": "4th heater switch",
|
||||
"underlying_entity_ids": "The device(s) to be controlled",
|
||||
"heater_keep_alive": "Switch keep-alive interval in seconds",
|
||||
"proportional_function": "Algorithm",
|
||||
"climate_entity_id": "1st underlying climate",
|
||||
"climate_entity2_id": "2nd underlying climate",
|
||||
"climate_entity3_id": "3rd underlying climate",
|
||||
"climate_entity4_id": "4th underlying climate",
|
||||
"ac_mode": "AC mode",
|
||||
"valve_entity_id": "1st valve number",
|
||||
"valve_entity2_id": "2nd valve number",
|
||||
"valve_entity3_id": "3rd valve number",
|
||||
"valve_entity4_id": "4th valve number",
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimum period",
|
||||
@@ -332,21 +299,10 @@
|
||||
"auto_fan_mode": "Auto fan mode"
|
||||
},
|
||||
"data_description": {
|
||||
"heater_entity_id": "Mandatory heater entity id",
|
||||
"heater_entity2_id": "Optional 2nd Heater entity id. Leave empty if not used",
|
||||
"heater_entity3_id": "Optional 3rd Heater entity id. Leave empty if not used",
|
||||
"heater_entity4_id": "Optional 4th Heater entity id. Leave empty if not used",
|
||||
"underlying_entity_ids": "The device(s) to be controlled - 1 is required",
|
||||
"heater_keep_alive": "Optional heater switch state refresh interval. Leave empty if not required.",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"climate_entity_id": "Underlying climate entity id",
|
||||
"climate_entity2_id": "2nd underlying climate entity id",
|
||||
"climate_entity3_id": "3rd underlying climate entity id",
|
||||
"climate_entity4_id": "4th underlying climate entity id",
|
||||
"ac_mode": "Use the Air Conditioning (AC) mode",
|
||||
"valve_entity_id": "1st valve number entity id",
|
||||
"valve_entity2_id": "2nd valve number entity id",
|
||||
"valve_entity3_id": "3rd valve number entity id",
|
||||
"valve_entity4_id": "4th valve number entity id",
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
@@ -536,7 +492,8 @@
|
||||
"state": {
|
||||
"power": "Shedding",
|
||||
"security": "Safety",
|
||||
"none": "Manual"
|
||||
"none": "Manual",
|
||||
"frost": "Frost"
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -8,7 +8,6 @@ from homeassistant.core import HomeAssistant, callback
|
||||
|
||||
from homeassistant.components.switch import SwitchEntity
|
||||
|
||||
from homeassistant.helpers.device_registry import DeviceInfo, DeviceEntryType
|
||||
from homeassistant.config_entries import ConfigEntry
|
||||
from homeassistant.helpers.restore_state import RestoreEntity
|
||||
from homeassistant.helpers.entity_platform import AddEntitiesCallback
|
||||
@@ -49,7 +48,7 @@ class AutoStartStopEnable(VersatileThermostatBaseEntity, SwitchEntity, RestoreEn
|
||||
):
|
||||
super().__init__(hass, unique_id, name)
|
||||
self._attr_name = "Enable auto start/stop"
|
||||
self._attr_unique_id = f"{self._device_name}_enbale_auto_start_stop"
|
||||
self._attr_unique_id = f"{self._device_name}_enable_auto_start_stop"
|
||||
self._default_value = (
|
||||
entry_infos.data.get(CONF_AUTO_START_STOP_LEVEL)
|
||||
!= AUTO_START_STOP_LEVEL_NONE
|
||||
@@ -59,7 +58,7 @@ class AutoStartStopEnable(VersatileThermostatBaseEntity, SwitchEntity, RestoreEn
|
||||
@property
|
||||
def icon(self) -> str | None:
|
||||
"""The icon"""
|
||||
return "mdi:power-settings"
|
||||
return "mdi:power-sleep"
|
||||
|
||||
async def async_added_to_hass(self):
|
||||
await super().async_added_to_hass()
|
||||
|
||||
@@ -20,41 +20,7 @@ from .commons import NowClass, round_to_nearest
|
||||
from .base_thermostat import BaseThermostat, ConfigData
|
||||
from .pi_algorithm import PITemperatureRegulator
|
||||
|
||||
from .const import (
|
||||
overrides,
|
||||
DOMAIN,
|
||||
CONF_CLIMATE,
|
||||
CONF_CLIMATE_2,
|
||||
CONF_CLIMATE_3,
|
||||
CONF_CLIMATE_4,
|
||||
CONF_AUTO_REGULATION_MODE,
|
||||
CONF_AUTO_REGULATION_NONE,
|
||||
CONF_AUTO_REGULATION_SLOW,
|
||||
CONF_AUTO_REGULATION_LIGHT,
|
||||
CONF_AUTO_REGULATION_MEDIUM,
|
||||
CONF_AUTO_REGULATION_STRONG,
|
||||
CONF_AUTO_REGULATION_EXPERT,
|
||||
CONF_AUTO_REGULATION_DTEMP,
|
||||
CONF_AUTO_REGULATION_PERIOD_MIN,
|
||||
CONF_AUTO_REGULATION_USE_DEVICE_TEMP,
|
||||
CONF_AUTO_FAN_MODE,
|
||||
CONF_AUTO_FAN_NONE,
|
||||
CONF_AUTO_FAN_LOW,
|
||||
CONF_AUTO_FAN_MEDIUM,
|
||||
CONF_AUTO_FAN_HIGH,
|
||||
CONF_AUTO_FAN_TURBO,
|
||||
RegulationParamSlow,
|
||||
RegulationParamLight,
|
||||
RegulationParamMedium,
|
||||
RegulationParamStrong,
|
||||
AUTO_FAN_DTEMP_THRESHOLD,
|
||||
AUTO_FAN_DEACTIVATED_MODES,
|
||||
CONF_AUTO_START_STOP_LEVEL,
|
||||
AUTO_START_STOP_LEVEL_NONE,
|
||||
TYPE_AUTO_START_STOP_LEVELS,
|
||||
UnknownEntity,
|
||||
EventType,
|
||||
)
|
||||
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
|
||||
|
||||
from .vtherm_api import VersatileThermostatAPI
|
||||
from .underlyings import UnderlyingClimate
|
||||
@@ -65,6 +31,10 @@ from .auto_start_stop_algorithm import (
|
||||
)
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
_LOGGER_ENERGY = logging.getLogger(
|
||||
"custom_components.versatile_thermostat.energy_debug"
|
||||
)
|
||||
|
||||
|
||||
HVAC_ACTION_ON = [ # pylint: disable=invalid-name
|
||||
HVACAction.COOLING,
|
||||
@@ -99,10 +69,7 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
{
|
||||
"is_over_climate",
|
||||
"start_hvac_action_date",
|
||||
"underlying_climate_0",
|
||||
"underlying_climate_1",
|
||||
"underlying_climate_2",
|
||||
"underlying_climate_3",
|
||||
"underlying_entities",
|
||||
"regulation_accumulated_error",
|
||||
"auto_regulation_mode",
|
||||
"auto_fan_mode",
|
||||
@@ -134,20 +101,15 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
"""Initialize the Thermostat"""
|
||||
|
||||
super().post_init(config_entry)
|
||||
for climate in [
|
||||
CONF_CLIMATE,
|
||||
CONF_CLIMATE_2,
|
||||
CONF_CLIMATE_3,
|
||||
CONF_CLIMATE_4,
|
||||
]:
|
||||
if config_entry.get(climate):
|
||||
self._underlyings.append(
|
||||
UnderlyingClimate(
|
||||
hass=self._hass,
|
||||
thermostat=self,
|
||||
climate_entity_id=config_entry.get(climate),
|
||||
)
|
||||
|
||||
for climate in config_entry.get(CONF_UNDERLYING_LIST):
|
||||
self._underlyings.append(
|
||||
UnderlyingClimate(
|
||||
hass=self._hass,
|
||||
thermostat=self,
|
||||
climate_entity_id=climate,
|
||||
)
|
||||
)
|
||||
|
||||
self.choose_auto_regulation_mode(
|
||||
config_entry.get(CONF_AUTO_REGULATION_MODE)
|
||||
@@ -176,9 +138,14 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
CONF_AUTO_REGULATION_USE_DEVICE_TEMP, False
|
||||
)
|
||||
|
||||
self._auto_start_stop_level = config_entry.get(
|
||||
CONF_AUTO_START_STOP_LEVEL, AUTO_START_STOP_LEVEL_NONE
|
||||
)
|
||||
use_auto_start_stop = config_entry.get(CONF_USE_AUTO_START_STOP_FEATURE, False)
|
||||
if use_auto_start_stop:
|
||||
self._auto_start_stop_level = config_entry.get(
|
||||
CONF_AUTO_START_STOP_LEVEL, AUTO_START_STOP_LEVEL_NONE
|
||||
)
|
||||
else:
|
||||
self._auto_start_stop_level = AUTO_START_STOP_LEVEL_NONE
|
||||
|
||||
# Instanciate the auto start stop algo
|
||||
self._auto_start_stop_algo = AutoStartStopDetectionAlgorithm(
|
||||
self._auto_start_stop_level, self.name
|
||||
@@ -533,18 +500,10 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
self._attr_extra_state_attributes["start_hvac_action_date"] = (
|
||||
self._underlying_climate_start_hvac_action_date
|
||||
)
|
||||
self._attr_extra_state_attributes["underlying_climate_0"] = self._underlyings[
|
||||
0
|
||||
].entity_id
|
||||
self._attr_extra_state_attributes["underlying_climate_1"] = (
|
||||
self._underlyings[1].entity_id if len(self._underlyings) > 1 else None
|
||||
)
|
||||
self._attr_extra_state_attributes["underlying_climate_2"] = (
|
||||
self._underlyings[2].entity_id if len(self._underlyings) > 2 else None
|
||||
)
|
||||
self._attr_extra_state_attributes["underlying_climate_3"] = (
|
||||
self._underlyings[3].entity_id if len(self._underlyings) > 3 else None
|
||||
)
|
||||
|
||||
self._attr_extra_state_attributes["underlying_entities"] = [
|
||||
underlying.entity_id for underlying in self._underlyings
|
||||
]
|
||||
|
||||
if self.is_regulated:
|
||||
self._attr_extra_state_attributes["is_regulated"] = self.is_regulated
|
||||
@@ -594,6 +553,7 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
] = self._auto_start_stop_algo.accumulated_error_threshold
|
||||
|
||||
self.async_write_ha_state()
|
||||
|
||||
_LOGGER.debug(
|
||||
"%s - Calling update_custom_attributes: %s",
|
||||
self,
|
||||
@@ -640,8 +600,18 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
|
||||
if self._total_energy is None:
|
||||
self._total_energy = added_energy
|
||||
_LOGGER_ENERGY.debug(
|
||||
"%s - incremente_energy set energy is %s",
|
||||
self,
|
||||
self._total_energy,
|
||||
)
|
||||
else:
|
||||
self._total_energy += added_energy
|
||||
_LOGGER_ENERGY.debug(
|
||||
"%s - incremente_energy incremented energy is %s",
|
||||
self,
|
||||
self._total_energy,
|
||||
)
|
||||
|
||||
_LOGGER.debug(
|
||||
"%s - added energy is %.3f . Total energy is now: %.3f",
|
||||
@@ -882,7 +852,8 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
changes = True
|
||||
|
||||
# try to manage new target temperature set if state if no other changes have been found
|
||||
if not changes:
|
||||
# and if a target temperature have already been sent
|
||||
if not changes and under.last_sent_temperature is not None:
|
||||
_LOGGER.debug(
|
||||
"Do temperature check. under.last_sent_temperature is %s, new_target_temp is %s",
|
||||
under.last_sent_temperature,
|
||||
@@ -906,71 +877,83 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
|
||||
await end_climate_changed(changes)
|
||||
|
||||
async def check_auto_start_stop(self):
|
||||
"""Check the auto-start-stop and an eventual action
|
||||
Return False if we should stop the control_heating method"""
|
||||
slope = (self.last_temperature_slope or 0) / 60 # to have the slope in °/min
|
||||
action = self._auto_start_stop_algo.calculate_action(
|
||||
self.hvac_mode,
|
||||
self._saved_hvac_mode,
|
||||
self.target_temperature,
|
||||
self.current_temperature,
|
||||
slope,
|
||||
self.now,
|
||||
)
|
||||
_LOGGER.debug("%s - auto_start_stop action is %s", self, action)
|
||||
if action == AUTO_START_STOP_ACTION_OFF and self.is_on:
|
||||
_LOGGER.info(
|
||||
"%s - Turning OFF the Vtherm due to auto-start-stop conditions",
|
||||
self,
|
||||
)
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_AUTO_START_STOP)
|
||||
await self.async_turn_off()
|
||||
|
||||
# Send an event
|
||||
self.send_event(
|
||||
event_type=EventType.AUTO_START_STOP_EVENT,
|
||||
data={
|
||||
"type": "stop",
|
||||
"name": self.name,
|
||||
"cause": "Auto stop conditions reached",
|
||||
"hvac_mode": self.hvac_mode,
|
||||
"saved_hvac_mode": self._saved_hvac_mode,
|
||||
"target_temperature": self.target_temperature,
|
||||
"current_temperature": self.current_temperature,
|
||||
"temperature_slope": round(slope, 3),
|
||||
"accumulated_error": self._auto_start_stop_algo.accumulated_error,
|
||||
"accumulated_error_threshold": self._auto_start_stop_algo.accumulated_error_threshold,
|
||||
},
|
||||
)
|
||||
|
||||
# Stop here
|
||||
return False
|
||||
elif action == AUTO_START_STOP_ACTION_ON:
|
||||
_LOGGER.info(
|
||||
"%s - Turning ON the Vtherm due to auto-start-stop conditions", self
|
||||
)
|
||||
await self.async_turn_on()
|
||||
|
||||
# Send an event
|
||||
self.send_event(
|
||||
event_type=EventType.AUTO_START_STOP_EVENT,
|
||||
data={
|
||||
"type": "start",
|
||||
"name": self.name,
|
||||
"cause": "Auto start conditions reached",
|
||||
"hvac_mode": self.hvac_mode,
|
||||
"saved_hvac_mode": self._saved_hvac_mode,
|
||||
"target_temperature": self.target_temperature,
|
||||
"current_temperature": self.current_temperature,
|
||||
"temperature_slope": round(slope, 3),
|
||||
"accumulated_error": self._auto_start_stop_algo.accumulated_error,
|
||||
"accumulated_error_threshold": self._auto_start_stop_algo.accumulated_error_threshold,
|
||||
},
|
||||
)
|
||||
|
||||
self.update_custom_attributes()
|
||||
|
||||
return True
|
||||
|
||||
@overrides
|
||||
async def async_control_heating(self, force=False, _=None) -> bool:
|
||||
"""The main function used to run the calculation at each cycle"""
|
||||
ret = await super().async_control_heating(force, _)
|
||||
|
||||
# Check if we need to auto start/stop the Vtherm
|
||||
if (
|
||||
self.auto_start_stop_enable
|
||||
and self._window_auto_algo.last_slope is not None
|
||||
):
|
||||
action = self._auto_start_stop_algo.calculate_action(
|
||||
self.hvac_mode,
|
||||
self._saved_hvac_mode,
|
||||
self.target_temperature,
|
||||
self.current_temperature,
|
||||
self._window_auto_algo.last_slope / 60, # to have the slope in °/min
|
||||
self.now,
|
||||
)
|
||||
_LOGGER.debug("%s - auto_start_stop action is %s", self, action)
|
||||
if action == AUTO_START_STOP_ACTION_OFF:
|
||||
_LOGGER.info(
|
||||
"%s - Turning OFF the Vtherm due to auto-start-stop conditions",
|
||||
self,
|
||||
)
|
||||
await self.async_turn_off()
|
||||
|
||||
# Send an event
|
||||
self.send_event(
|
||||
event_type=EventType.AUTO_START_STOP_EVENT,
|
||||
data={
|
||||
"type": "stop",
|
||||
"name:": self.name,
|
||||
"cause": "Auto stop conditions reached",
|
||||
"hvac_mode": self.hvac_mode,
|
||||
"saved_hvac_mode": self._saved_hvac_mode,
|
||||
"target_temperature": self.target_temperature,
|
||||
"current_temperature": self.current_temperature,
|
||||
"temperature_slope": self._window_auto_algo.last_slope,
|
||||
},
|
||||
)
|
||||
|
||||
# Stop here
|
||||
if self.auto_start_stop_enable:
|
||||
continu = await self.check_auto_start_stop()
|
||||
if not continu:
|
||||
return ret
|
||||
elif action == AUTO_START_STOP_ACTION_ON:
|
||||
_LOGGER.info(
|
||||
"%s - Turning ON the Vtherm due to auto-start-stop conditions", self
|
||||
)
|
||||
await self.async_turn_on()
|
||||
|
||||
# Send an event
|
||||
self.send_event(
|
||||
event_type=EventType.AUTO_START_STOP_EVENT,
|
||||
data={
|
||||
"type": "start",
|
||||
"name:": self.name,
|
||||
"cause": "Auto start conditions reached",
|
||||
"hvac_mode": self.hvac_mode,
|
||||
"saved_hvac_mode": self._saved_hvac_mode,
|
||||
"target_temperature": self.target_temperature,
|
||||
"current_temperature": self.current_temperature,
|
||||
"temperature_slope": self._window_auto_algo.last_slope,
|
||||
},
|
||||
)
|
||||
|
||||
self.update_custom_attributes()
|
||||
else:
|
||||
_LOGGER.debug("%s - auto start/stop is disabled")
|
||||
|
||||
@@ -987,6 +970,7 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
|
||||
def set_auto_start_stop_enable(self, is_enabled: bool):
|
||||
"""Enable/Disable the auto-start/stop feature"""
|
||||
self._is_auto_start_stop_enabled = is_enabled
|
||||
self.update_custom_attributes()
|
||||
|
||||
@property
|
||||
def auto_regulation_mode(self) -> str | None:
|
||||
|
||||
@@ -10,10 +10,7 @@ from homeassistant.helpers.event import (
|
||||
from homeassistant.components.climate import HVACMode
|
||||
|
||||
from .const import (
|
||||
CONF_HEATER,
|
||||
CONF_HEATER_2,
|
||||
CONF_HEATER_3,
|
||||
CONF_HEATER_4,
|
||||
CONF_UNDERLYING_LIST,
|
||||
CONF_HEATER_KEEP_ALIVE,
|
||||
CONF_INVERSE_SWITCH,
|
||||
overrides,
|
||||
@@ -24,7 +21,9 @@ from .underlyings import UnderlyingSwitch
|
||||
from .prop_algorithm import PropAlgorithm
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
_LOGGER_ENERGY = logging.getLogger(
|
||||
"custom_components.versatile_thermostat.energy_debug"
|
||||
)
|
||||
|
||||
class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
|
||||
"""Representation of a base class for a Versatile Thermostat over a switch."""
|
||||
@@ -35,10 +34,7 @@ class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
|
||||
{
|
||||
"is_over_switch",
|
||||
"is_inversed",
|
||||
"underlying_switch_0",
|
||||
"underlying_switch_1",
|
||||
"underlying_switch_2",
|
||||
"underlying_switch_3",
|
||||
"underlying_entities",
|
||||
"on_time_sec",
|
||||
"off_time_sec",
|
||||
"cycle_min",
|
||||
@@ -90,13 +86,7 @@ class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
|
||||
self.name,
|
||||
)
|
||||
|
||||
lst_switches = [config_entry.get(CONF_HEATER)]
|
||||
if config_entry.get(CONF_HEATER_2):
|
||||
lst_switches.append(config_entry.get(CONF_HEATER_2))
|
||||
if config_entry.get(CONF_HEATER_3):
|
||||
lst_switches.append(config_entry.get(CONF_HEATER_3))
|
||||
if config_entry.get(CONF_HEATER_4):
|
||||
lst_switches.append(config_entry.get(CONF_HEATER_4))
|
||||
lst_switches = config_entry.get(CONF_UNDERLYING_LIST)
|
||||
|
||||
delta_cycle = self._cycle_min * 60 / len(lst_switches)
|
||||
for idx, switch in enumerate(lst_switches):
|
||||
@@ -140,16 +130,10 @@ class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
|
||||
self._attr_extra_state_attributes["is_over_switch"] = self.is_over_switch
|
||||
self._attr_extra_state_attributes["is_inversed"] = self.is_inversed
|
||||
self._attr_extra_state_attributes["keep_alive_sec"] = under0.keep_alive_sec
|
||||
self._attr_extra_state_attributes["underlying_switch_0"] = under0.entity_id
|
||||
self._attr_extra_state_attributes["underlying_switch_1"] = (
|
||||
self._underlyings[1].entity_id if len(self._underlyings) > 1 else None
|
||||
)
|
||||
self._attr_extra_state_attributes["underlying_switch_2"] = (
|
||||
self._underlyings[2].entity_id if len(self._underlyings) > 2 else None
|
||||
)
|
||||
self._attr_extra_state_attributes["underlying_switch_3"] = (
|
||||
self._underlyings[3].entity_id if len(self._underlyings) > 3 else None
|
||||
)
|
||||
|
||||
self._attr_extra_state_attributes["underlying_entities"] = [
|
||||
underlying.entity_id for underlying in self._underlyings
|
||||
]
|
||||
|
||||
self._attr_extra_state_attributes[
|
||||
"on_percent"
|
||||
@@ -201,8 +185,18 @@ class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
|
||||
|
||||
if self._total_energy is None:
|
||||
self._total_energy = added_energy
|
||||
_LOGGER_ENERGY.debug(
|
||||
"%s - incremente_energy set energy is %s",
|
||||
self,
|
||||
self._total_energy,
|
||||
)
|
||||
else:
|
||||
self._total_energy += added_energy
|
||||
_LOGGER_ENERGY.debug(
|
||||
"%s - incremente_energy increment energy is %s",
|
||||
self,
|
||||
self._total_energy,
|
||||
)
|
||||
|
||||
self.update_custom_attributes()
|
||||
|
||||
|
||||
@@ -15,10 +15,7 @@ from .base_thermostat import BaseThermostat, ConfigData
|
||||
from .prop_algorithm import PropAlgorithm
|
||||
|
||||
from .const import (
|
||||
CONF_VALVE,
|
||||
CONF_VALVE_2,
|
||||
CONF_VALVE_3,
|
||||
CONF_VALVE_4,
|
||||
CONF_UNDERLYING_LIST,
|
||||
# This is not really self-regulation but regulation here
|
||||
CONF_AUTO_REGULATION_DTEMP,
|
||||
CONF_AUTO_REGULATION_PERIOD_MIN,
|
||||
@@ -28,7 +25,9 @@ from .const import (
|
||||
from .underlyings import UnderlyingValve
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
_LOGGER_ENERGY = logging.getLogger(
|
||||
"custom_components.versatile_thermostat.energy_debug"
|
||||
)
|
||||
|
||||
class ThermostatOverValve(BaseThermostat[UnderlyingValve]): # pylint: disable=abstract-method
|
||||
"""Representation of a class for a Versatile Thermostat over a Valve"""
|
||||
@@ -37,10 +36,7 @@ class ThermostatOverValve(BaseThermostat[UnderlyingValve]): # pylint: disable=a
|
||||
frozenset(
|
||||
{
|
||||
"is_over_valve",
|
||||
"underlying_valve_0",
|
||||
"underlying_valve_1",
|
||||
"underlying_valve_2",
|
||||
"underlying_valve_3",
|
||||
"underlying_entities",
|
||||
"on_time_sec",
|
||||
"off_time_sec",
|
||||
"cycle_min",
|
||||
@@ -105,13 +101,7 @@ class ThermostatOverValve(BaseThermostat[UnderlyingValve]): # pylint: disable=a
|
||||
self.name,
|
||||
)
|
||||
|
||||
lst_valves = [config_entry.get(CONF_VALVE)]
|
||||
if config_entry.get(CONF_VALVE_2):
|
||||
lst_valves.append(config_entry.get(CONF_VALVE_2))
|
||||
if config_entry.get(CONF_VALVE_3):
|
||||
lst_valves.append(config_entry.get(CONF_VALVE_3))
|
||||
if config_entry.get(CONF_VALVE_4):
|
||||
lst_valves.append(config_entry.get(CONF_VALVE_4))
|
||||
lst_valves = config_entry.get(CONF_UNDERLYING_LIST)
|
||||
|
||||
for _, valve in enumerate(lst_valves):
|
||||
self._underlyings.append(
|
||||
@@ -163,18 +153,10 @@ class ThermostatOverValve(BaseThermostat[UnderlyingValve]): # pylint: disable=a
|
||||
"valve_open_percent"
|
||||
] = self.valve_open_percent
|
||||
self._attr_extra_state_attributes["is_over_valve"] = self.is_over_valve
|
||||
self._attr_extra_state_attributes["underlying_valve_0"] = self._underlyings[
|
||||
0
|
||||
].entity_id
|
||||
self._attr_extra_state_attributes["underlying_valve_1"] = (
|
||||
self._underlyings[1].entity_id if len(self._underlyings) > 1 else None
|
||||
)
|
||||
self._attr_extra_state_attributes["underlying_valve_2"] = (
|
||||
self._underlyings[2].entity_id if len(self._underlyings) > 2 else None
|
||||
)
|
||||
self._attr_extra_state_attributes["underlying_valve_3"] = (
|
||||
self._underlyings[3].entity_id if len(self._underlyings) > 3 else None
|
||||
)
|
||||
|
||||
self._attr_extra_state_attributes["underlying_entities"] = [
|
||||
underlying.entity_id for underlying in self._underlyings
|
||||
]
|
||||
|
||||
self._attr_extra_state_attributes[
|
||||
"on_percent"
|
||||
@@ -285,8 +267,18 @@ class ThermostatOverValve(BaseThermostat[UnderlyingValve]): # pylint: disable=a
|
||||
|
||||
if self._total_energy is None:
|
||||
self._total_energy = added_energy
|
||||
_LOGGER_ENERGY.debug(
|
||||
"%s - incremente_energy set energy is %s",
|
||||
self,
|
||||
self._total_energy,
|
||||
)
|
||||
else:
|
||||
self._total_energy += added_energy
|
||||
_LOGGER_ENERGY.debug(
|
||||
"%s - get_my_previous_state increment energy is %s",
|
||||
self,
|
||||
self._total_energy,
|
||||
)
|
||||
|
||||
self.update_custom_attributes()
|
||||
|
||||
|
||||
@@ -64,7 +64,7 @@
|
||||
"use_motion_feature": "Use motion detection",
|
||||
"use_power_feature": "Use power management",
|
||||
"use_presence_feature": "Use presence detection",
|
||||
"use_central_boiler_feature": "Use a central boiler. Check to add a control to your central boiler. You will have to configure the VTherm which will have a control of the central boiler after seecting this checkbox to take effect. If one VTherm requires heating, the boiler will be turned on. If no VTherm requires heating, the boiler will be turned off. Commands for turning on/off the central boiler are given in the related configuration page",
|
||||
"use_central_boiler_feature": "Use a central boiler. Check to add a control to your central boiler. You will have to configure the VTherm which will have a control of the central boiler after selecting this checkbox to take effect. If one VTherm requires heating, the boiler will be turned on. If no VTherm requires heating, the boiler will be turned off. Commands for turning on/off the central boiler are given in the related configuration page",
|
||||
"use_auto_start_stop_feature": "Use the auto start and stop feature"
|
||||
}
|
||||
},
|
||||
@@ -72,21 +72,10 @@
|
||||
"title": "Linked entities",
|
||||
"description": "Linked entities attributes",
|
||||
"data": {
|
||||
"heater_entity_id": "1st heater switch",
|
||||
"heater_entity2_id": "2nd heater switch",
|
||||
"heater_entity3_id": "3rd heater switch",
|
||||
"heater_entity4_id": "4th heater switch",
|
||||
"underlying_entity_ids": "The device(s) to be controlled",
|
||||
"heater_keep_alive": "Switch keep-alive interval in seconds",
|
||||
"proportional_function": "Algorithm",
|
||||
"climate_entity_id": "1st underlying climate",
|
||||
"climate_entity2_id": "2nd underlying climate",
|
||||
"climate_entity3_id": "3rd underlying climate",
|
||||
"climate_entity4_id": "4th underlying climate",
|
||||
"ac_mode": "AC mode",
|
||||
"valve_entity_id": "1st valve number",
|
||||
"valve_entity2_id": "2nd valve number",
|
||||
"valve_entity3_id": "3rd valve number",
|
||||
"valve_entity4_id": "4th valve number",
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimum period",
|
||||
@@ -95,21 +84,10 @@
|
||||
"auto_fan_mode": "Auto fan mode"
|
||||
},
|
||||
"data_description": {
|
||||
"heater_entity_id": "Mandatory heater entity id",
|
||||
"heater_entity2_id": "Optional 2nd Heater entity id. Leave empty if not required",
|
||||
"heater_entity3_id": "Optional 3rd Heater entity id. Leave empty if not required",
|
||||
"heater_entity4_id": "Optional 4th Heater entity id. Leave empty if not required",
|
||||
"underlying_entity_ids": "The device(s) to be controlled - 1 is required",
|
||||
"heater_keep_alive": "Optional heater switch state refresh interval. Leave empty if not required.",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"climate_entity_id": "Underlying climate entity id",
|
||||
"climate_entity2_id": "2nd underlying climate entity id",
|
||||
"climate_entity3_id": "3rd underlying climate entity id",
|
||||
"climate_entity4_id": "4th underlying climate entity id",
|
||||
"ac_mode": "Use the Air Conditioning (AC) mode",
|
||||
"valve_entity_id": "1st valve number entity id",
|
||||
"valve_entity2_id": "2nd valve number entity id",
|
||||
"valve_entity3_id": "3rd valve number entity id",
|
||||
"valve_entity4_id": "4th valve number entity id",
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
@@ -309,21 +287,10 @@
|
||||
"title": "Entities - {name}",
|
||||
"description": "Linked entities attributes",
|
||||
"data": {
|
||||
"heater_entity_id": "1st heater switch",
|
||||
"heater_entity2_id": "2nd heater switch",
|
||||
"heater_entity3_id": "3rd heater switch",
|
||||
"heater_entity4_id": "4th heater switch",
|
||||
"underlying_entity_ids": "The device(s) to be controlled",
|
||||
"heater_keep_alive": "Switch keep-alive interval in seconds",
|
||||
"proportional_function": "Algorithm",
|
||||
"climate_entity_id": "1st underlying climate",
|
||||
"climate_entity2_id": "2nd underlying climate",
|
||||
"climate_entity3_id": "3rd underlying climate",
|
||||
"climate_entity4_id": "4th underlying climate",
|
||||
"ac_mode": "AC mode",
|
||||
"valve_entity_id": "1st valve number",
|
||||
"valve_entity2_id": "2nd valve number",
|
||||
"valve_entity3_id": "3rd valve number",
|
||||
"valve_entity4_id": "4th valve number",
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimum period",
|
||||
@@ -332,21 +299,10 @@
|
||||
"auto_fan_mode": "Auto fan mode"
|
||||
},
|
||||
"data_description": {
|
||||
"heater_entity_id": "Mandatory heater entity id",
|
||||
"heater_entity2_id": "Optional 2nd Heater entity id. Leave empty if not used",
|
||||
"heater_entity3_id": "Optional 3rd Heater entity id. Leave empty if not used",
|
||||
"heater_entity4_id": "Optional 4th Heater entity id. Leave empty if not used",
|
||||
"underlying_entity_ids": "The device(s) to be controlled - 1 is required",
|
||||
"heater_keep_alive": "Optional heater switch state refresh interval. Leave empty if not required.",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"climate_entity_id": "Underlying climate entity id",
|
||||
"climate_entity2_id": "2nd underlying climate entity id",
|
||||
"climate_entity3_id": "3rd underlying climate entity id",
|
||||
"climate_entity4_id": "4th underlying climate entity id",
|
||||
"ac_mode": "Use the Air Conditioning (AC) mode",
|
||||
"valve_entity_id": "1st valve number entity id",
|
||||
"valve_entity2_id": "2nd valve number entity id",
|
||||
"valve_entity3_id": "3rd valve number entity id",
|
||||
"valve_entity4_id": "4th valve number entity id",
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
@@ -536,7 +492,8 @@
|
||||
"state": {
|
||||
"power": "Shedding",
|
||||
"security": "Safety",
|
||||
"none": "Manual"
|
||||
"none": "Manual",
|
||||
"frost": "Frost"
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -590,4 +547,4 @@
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -554,7 +554,8 @@
|
||||
"state": {
|
||||
"power": "Délestage",
|
||||
"security": "Sécurité",
|
||||
"none": "Manuel"
|
||||
"none": "Manuel",
|
||||
"frost": "Hors Gel"
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -364,7 +364,8 @@
|
||||
"state": {
|
||||
"power": "Ripartizione",
|
||||
"security": "Sicurezza",
|
||||
"none": "Manuale"
|
||||
"none": "Manuale",
|
||||
"frost": "Gelo"
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -150,10 +150,11 @@ class VersatileThermostatAPI(dict):
|
||||
return entity.state
|
||||
return None
|
||||
|
||||
async def init_vtherm_links(self):
|
||||
async def init_vtherm_links(self, entry_id=None):
|
||||
"""Initialize all VTherms entities links
|
||||
This method is called when HA is fully started (and all entities should be initialized)
|
||||
Or when we need to reload all VTherm links (with Number temp entities, central boiler, ...)
|
||||
If entry_id is set, only the VTherm of this entry will be reloaded
|
||||
"""
|
||||
await self.reload_central_boiler_binary_listener()
|
||||
await self.reload_central_boiler_entities_list()
|
||||
@@ -175,7 +176,8 @@ class VersatileThermostatAPI(dict):
|
||||
entity.device_info
|
||||
and entity.device_info.get("model", None) == DOMAIN
|
||||
):
|
||||
await entity.async_startup(self.find_central_configuration())
|
||||
if entry_id is None or entry_id == entity.unique_id:
|
||||
await entity.async_startup(self.find_central_configuration())
|
||||
|
||||
async def init_vtherm_preset_with_central(self):
|
||||
"""Init all VTherm presets when the VTherm uses central temperature"""
|
||||
|
||||
@@ -74,7 +74,7 @@ MOCK_TH_OVER_SWITCH_CENTRAL_MAIN_CONFIG = {
|
||||
}
|
||||
|
||||
MOCK_TH_OVER_SWITCH_TYPE_CONFIG = {
|
||||
CONF_HEATER: "switch.mock_switch",
|
||||
CONF_UNDERLYING_LIST: ["switch.mock_switch"],
|
||||
CONF_HEATER_KEEP_ALIVE: 0,
|
||||
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
|
||||
CONF_AC_MODE: False,
|
||||
@@ -82,17 +82,14 @@ MOCK_TH_OVER_SWITCH_TYPE_CONFIG = {
|
||||
}
|
||||
|
||||
MOCK_TH_OVER_SWITCH_AC_TYPE_CONFIG = {
|
||||
CONF_HEATER: "switch.mock_air_conditioner",
|
||||
CONF_UNDERLYING_LIST: ["switch.mock_air_conditioner"],
|
||||
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
|
||||
CONF_AC_MODE: True,
|
||||
CONF_INVERSE_SWITCH: False,
|
||||
}
|
||||
|
||||
MOCK_TH_OVER_4SWITCH_TYPE_CONFIG = {
|
||||
CONF_HEATER: "switch.mock_4switch0",
|
||||
CONF_HEATER_2: "switch.mock_4switch1",
|
||||
CONF_HEATER_3: "switch.mock_4switch2",
|
||||
CONF_HEATER_4: "switch.mock_4switch3",
|
||||
CONF_UNDERLYING_LIST: ["switch.mock_4switch0", "switch.mock_4switch1","switch.mock_4switch2","switch.mock_4switch3"],
|
||||
CONF_HEATER_KEEP_ALIVE: 0,
|
||||
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
|
||||
CONF_AC_MODE: False,
|
||||
@@ -105,7 +102,7 @@ MOCK_TH_OVER_SWITCH_TPI_CONFIG = {
|
||||
}
|
||||
|
||||
MOCK_TH_OVER_CLIMATE_TYPE_CONFIG = {
|
||||
CONF_CLIMATE: "climate.mock_climate",
|
||||
CONF_UNDERLYING_LIST: ["climate.mock_climate"],
|
||||
CONF_AC_MODE: False,
|
||||
CONF_AUTO_REGULATION_MODE: CONF_AUTO_REGULATION_STRONG,
|
||||
CONF_AUTO_REGULATION_DTEMP: 0.5,
|
||||
@@ -115,7 +112,7 @@ MOCK_TH_OVER_CLIMATE_TYPE_CONFIG = {
|
||||
}
|
||||
|
||||
MOCK_TH_OVER_CLIMATE_TYPE_USE_DEVICE_TEMP_CONFIG = {
|
||||
CONF_CLIMATE: "climate.mock_climate",
|
||||
CONF_UNDERLYING_LIST: ["climate.mock_climate"],
|
||||
CONF_AC_MODE: False,
|
||||
CONF_AUTO_REGULATION_MODE: CONF_AUTO_REGULATION_STRONG,
|
||||
CONF_AUTO_REGULATION_DTEMP: 0.1,
|
||||
@@ -125,13 +122,13 @@ MOCK_TH_OVER_CLIMATE_TYPE_USE_DEVICE_TEMP_CONFIG = {
|
||||
}
|
||||
|
||||
MOCK_TH_OVER_CLIMATE_TYPE_NOT_REGULATED_CONFIG = {
|
||||
CONF_CLIMATE: "climate.mock_climate",
|
||||
CONF_UNDERLYING_LIST: ["climate.mock_climate"],
|
||||
CONF_AC_MODE: False,
|
||||
CONF_AUTO_REGULATION_MODE: CONF_AUTO_REGULATION_NONE,
|
||||
}
|
||||
|
||||
MOCK_TH_OVER_CLIMATE_TYPE_AC_CONFIG = {
|
||||
CONF_CLIMATE: "climate.mock_climate",
|
||||
CONF_UNDERLYING_LIST: ["climate.mock_climate"],
|
||||
CONF_AC_MODE: True,
|
||||
CONF_AUTO_REGULATION_MODE: CONF_AUTO_REGULATION_STRONG,
|
||||
CONF_AUTO_REGULATION_DTEMP: 0.5,
|
||||
|
||||
@@ -6,6 +6,7 @@ import logging
|
||||
from unittest.mock import patch, call
|
||||
|
||||
from homeassistant.components.climate import HVACMode
|
||||
from homeassistant.components.switch import DOMAIN as SWITCH_DOMAIN
|
||||
|
||||
from custom_components.versatile_thermostat.thermostat_climate import (
|
||||
ThermostatOverClimate,
|
||||
@@ -14,7 +15,6 @@ from custom_components.versatile_thermostat.auto_start_stop_algorithm import (
|
||||
AutoStartStopDetectionAlgorithm,
|
||||
AUTO_START_STOP_ACTION_NOTHING,
|
||||
AUTO_START_STOP_ACTION_OFF,
|
||||
AUTO_START_STOP_ACTION_ON,
|
||||
)
|
||||
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
|
||||
|
||||
@@ -72,7 +72,7 @@ async def test_auto_start_stop_algo_slow_heat_off(hass: HomeAssistant):
|
||||
assert ret == AUTO_START_STOP_ACTION_NOTHING
|
||||
|
||||
# 4 .No change on accumulated error because the new measure is too near the last one
|
||||
now = now + timedelta(minutes=1)
|
||||
now = now + timedelta(seconds=11)
|
||||
ret = algo.calculate_action(
|
||||
hvac_mode=HVACMode.HEAT,
|
||||
saved_hvac_mode=HVACMode.OFF,
|
||||
@@ -225,6 +225,7 @@ async def test_auto_start_stop_none_vtherm(
|
||||
CONF_USE_WINDOW_FEATURE: False,
|
||||
CONF_USE_MOTION_FEATURE: False,
|
||||
CONF_USE_POWER_FEATURE: False,
|
||||
CONF_USE_AUTO_START_STOP_FEATURE: False,
|
||||
CONF_USE_PRESENCE_FEATURE: True,
|
||||
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
|
||||
CONF_CLIMATE: "climate.mock_climate",
|
||||
@@ -267,6 +268,12 @@ async def test_auto_start_stop_none_vtherm(
|
||||
# 1. Vtherm auto-start/stop should be in NONE mode
|
||||
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_NONE
|
||||
|
||||
# 2. We should not find any switch Enable entity
|
||||
assert (
|
||||
search_entity(hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN)
|
||||
is None
|
||||
)
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
@@ -310,6 +317,7 @@ async def test_auto_start_stop_medium_heat_vtherm(
|
||||
CONF_USE_WINDOW_FEATURE: False,
|
||||
CONF_USE_MOTION_FEATURE: False,
|
||||
CONF_USE_POWER_FEATURE: False,
|
||||
CONF_USE_AUTO_START_STOP_FEATURE: True,
|
||||
CONF_USE_PRESENCE_FEATURE: True,
|
||||
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
|
||||
CONF_CLIMATE: "climate.mock_climate",
|
||||
@@ -350,8 +358,13 @@ async def test_auto_start_stop_medium_heat_vtherm(
|
||||
|
||||
assert vtherm._attr_extra_state_attributes["auto_start_stop_dtmin"] == 15
|
||||
|
||||
# 1. Vtherm auto-start/stop should be in MEDIUM mode
|
||||
# 1. Vtherm auto-start/stop should be in MEDIUM mode and an enable entity should exists
|
||||
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_MEDIUM
|
||||
enable_entity = search_entity(
|
||||
hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN
|
||||
)
|
||||
assert enable_entity is not None
|
||||
assert enable_entity.state == STATE_ON
|
||||
|
||||
tz = get_tz(hass) # pylint: disable=invalid-name
|
||||
now: datetime = datetime.now(tz=tz)
|
||||
@@ -369,6 +382,8 @@ async def test_auto_start_stop_medium_heat_vtherm(
|
||||
|
||||
# 3. Set current temperature to 19 5 min later
|
||||
now = now + timedelta(minutes=5)
|
||||
# reset accumulated error (only for testing)
|
||||
vtherm._auto_start_stop_algo._accumulated_error = 0
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event:
|
||||
@@ -409,6 +424,7 @@ async def test_auto_start_stop_medium_heat_vtherm(
|
||||
|
||||
# VTherm should have been stopped
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason == HVAC_OFF_REASON_AUTO_START_STOP
|
||||
|
||||
# accumulated_error = -2.5 + target - current = -2 x 5 min / 2 capped to 5
|
||||
assert vtherm._auto_start_stop_algo.accumulated_error == -5
|
||||
@@ -421,12 +437,15 @@ async def test_auto_start_stop_medium_heat_vtherm(
|
||||
event_type=EventType.AUTO_START_STOP_EVENT,
|
||||
data={
|
||||
"type": "stop",
|
||||
"name": "overClimate",
|
||||
"cause": "Auto stop conditions reached",
|
||||
"hvac_mode": HVACMode.OFF,
|
||||
"saved_hvac_mode": HVACMode.HEAT,
|
||||
"target_temperature": 19.0,
|
||||
"current_temperature": 21.0,
|
||||
"temperature_slope": 10.03,
|
||||
"temperature_slope": 0.167,
|
||||
"accumulated_error": -5,
|
||||
"accumulated_error_threshold": 5,
|
||||
},
|
||||
)
|
||||
]
|
||||
@@ -457,6 +476,7 @@ async def test_auto_start_stop_medium_heat_vtherm(
|
||||
|
||||
# VTherm should stay stopped cause slope is too low to allow the turn to On
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason == HVAC_OFF_REASON_AUTO_START_STOP
|
||||
|
||||
# 7. Set temperature to over the target, so that it will turn to heat
|
||||
now = now + timedelta(minutes=20)
|
||||
@@ -472,6 +492,8 @@ async def test_auto_start_stop_medium_heat_vtherm(
|
||||
|
||||
# VTherm should have been stopped
|
||||
assert vtherm.hvac_mode == HVACMode.HEAT
|
||||
assert vtherm.hvac_off_reason is None
|
||||
|
||||
# a message should have been sent
|
||||
assert mock_send_event.call_count >= 1
|
||||
mock_send_event.assert_has_calls(
|
||||
@@ -480,12 +502,15 @@ async def test_auto_start_stop_medium_heat_vtherm(
|
||||
event_type=EventType.AUTO_START_STOP_EVENT,
|
||||
data={
|
||||
"type": "start",
|
||||
"name": "overClimate",
|
||||
"cause": "Auto start conditions reached",
|
||||
"hvac_mode": HVACMode.HEAT,
|
||||
"saved_hvac_mode": HVACMode.HEAT, # saved don't change
|
||||
"target_temperature": 19.0,
|
||||
"current_temperature": 18.0,
|
||||
"temperature_slope": -2.06,
|
||||
"temperature_slope": -0.034,
|
||||
"accumulated_error": 5,
|
||||
"accumulated_error_threshold": 5,
|
||||
},
|
||||
)
|
||||
]
|
||||
@@ -545,9 +570,10 @@ async def test_auto_start_stop_fast_ac_vtherm(
|
||||
CONF_USE_WINDOW_FEATURE: False,
|
||||
CONF_USE_MOTION_FEATURE: False,
|
||||
CONF_USE_POWER_FEATURE: False,
|
||||
CONF_USE_AUTO_START_STOP_FEATURE: True,
|
||||
CONF_USE_PRESENCE_FEATURE: True,
|
||||
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
|
||||
CONF_CLIMATE: "climate.mock_climate",
|
||||
CONF_UNDERLYING_LIST: ["climate.mock_climate"],
|
||||
CONF_MINIMAL_ACTIVATION_DELAY: 30,
|
||||
CONF_SECURITY_DELAY_MIN: 5,
|
||||
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
|
||||
@@ -599,11 +625,13 @@ async def test_auto_start_stop_fast_ac_vtherm(
|
||||
await hass.async_block_till_done()
|
||||
|
||||
assert vtherm.target_temperature == 25.0
|
||||
# VTherm should be heating
|
||||
# VTherm should be cooling
|
||||
assert vtherm.hvac_mode == HVACMode.COOL
|
||||
|
||||
# 3. Set current temperature to 19 5 min later
|
||||
now = now + timedelta(minutes=5)
|
||||
# reset accumulated error for test
|
||||
vtherm._auto_start_stop_algo._accumulated_error = 0
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event:
|
||||
@@ -611,7 +639,7 @@ async def test_auto_start_stop_fast_ac_vtherm(
|
||||
await send_temperature_change_event(vtherm, 25, now, True)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
# VTherm should still be heating
|
||||
# VTherm should still be cooling
|
||||
assert vtherm.hvac_mode == HVACMode.COOL
|
||||
assert mock_send_event.call_count == 0
|
||||
assert (
|
||||
@@ -641,12 +669,15 @@ async def test_auto_start_stop_fast_ac_vtherm(
|
||||
event_type=EventType.AUTO_START_STOP_EVENT,
|
||||
data={
|
||||
"type": "stop",
|
||||
"name": "overClimate",
|
||||
"cause": "Auto stop conditions reached",
|
||||
"hvac_mode": HVACMode.OFF,
|
||||
"saved_hvac_mode": HVACMode.COOL,
|
||||
"target_temperature": 25.0,
|
||||
"current_temperature": 23.0,
|
||||
"temperature_slope": -16.8,
|
||||
"temperature_slope": -0.28,
|
||||
"accumulated_error": 2,
|
||||
"accumulated_error_threshold": 2,
|
||||
},
|
||||
)
|
||||
]
|
||||
@@ -664,18 +695,18 @@ async def test_auto_start_stop_fast_ac_vtherm(
|
||||
)
|
||||
|
||||
# 5. Set temperature to over the target, but slope is too low -> no change
|
||||
now = now + timedelta(minutes=20)
|
||||
now = now + timedelta(minutes=30)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event:
|
||||
vtherm._set_now(now)
|
||||
await send_temperature_change_event(vtherm, 26, now, True)
|
||||
await send_temperature_change_event(vtherm, 25.5, now, True)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
# accumulated_error = 2/2 + target - current = -1 x 20 min / 2 capped to 2
|
||||
assert vtherm._auto_start_stop_algo.accumulated_error == -2
|
||||
|
||||
# VTherm should have been stopped
|
||||
# VTherm should stay stopped
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
# a message should have been sent
|
||||
assert mock_send_event.call_count == 0
|
||||
@@ -702,12 +733,15 @@ async def test_auto_start_stop_fast_ac_vtherm(
|
||||
event_type=EventType.AUTO_START_STOP_EVENT,
|
||||
data={
|
||||
"type": "start",
|
||||
"name": "overClimate",
|
||||
"cause": "Auto start conditions reached",
|
||||
"hvac_mode": HVACMode.COOL,
|
||||
"saved_hvac_mode": HVACMode.COOL, # saved don't change
|
||||
"target_temperature": 25.0,
|
||||
"current_temperature": 26.5,
|
||||
"temperature_slope": 5.74,
|
||||
"temperature_slope": 0.112,
|
||||
"accumulated_error": -2,
|
||||
"accumulated_error_threshold": 2,
|
||||
},
|
||||
)
|
||||
]
|
||||
@@ -767,6 +801,7 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change(
|
||||
CONF_USE_WINDOW_FEATURE: False,
|
||||
CONF_USE_MOTION_FEATURE: False,
|
||||
CONF_USE_POWER_FEATURE: False,
|
||||
CONF_USE_AUTO_START_STOP_FEATURE: True,
|
||||
CONF_USE_PRESENCE_FEATURE: True,
|
||||
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
|
||||
CONF_CLIMATE: "climate.mock_climate",
|
||||
@@ -826,6 +861,7 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change(
|
||||
|
||||
# 3. Set current temperature to 21 5 min later to auto-stop
|
||||
now = now + timedelta(minutes=5)
|
||||
vtherm._auto_start_stop_algo._accumulated_error = 0
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event:
|
||||
@@ -846,12 +882,15 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change(
|
||||
event_type=EventType.AUTO_START_STOP_EVENT,
|
||||
data={
|
||||
"type": "stop",
|
||||
"name": "overClimate",
|
||||
"cause": "Auto stop conditions reached",
|
||||
"hvac_mode": HVACMode.OFF,
|
||||
"saved_hvac_mode": HVACMode.HEAT,
|
||||
"target_temperature": 17.0,
|
||||
"current_temperature": 19.0,
|
||||
"temperature_slope": 18.0,
|
||||
"temperature_slope": 0.3,
|
||||
"accumulated_error": -2,
|
||||
"accumulated_error_threshold": 2,
|
||||
},
|
||||
)
|
||||
]
|
||||
@@ -900,12 +939,15 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change(
|
||||
event_type=EventType.AUTO_START_STOP_EVENT,
|
||||
data={
|
||||
"type": "start",
|
||||
"name": "overClimate",
|
||||
"cause": "Auto start conditions reached",
|
||||
"hvac_mode": HVACMode.HEAT,
|
||||
"saved_hvac_mode": HVACMode.HEAT, # saved don't change
|
||||
"target_temperature": 21.0,
|
||||
"current_temperature": 17.0,
|
||||
"temperature_slope": -5.19,
|
||||
"temperature_slope": -0.087,
|
||||
"accumulated_error": 2,
|
||||
"accumulated_error_threshold": 2,
|
||||
},
|
||||
)
|
||||
]
|
||||
@@ -921,3 +963,503 @@ async def test_auto_start_stop_medium_heat_vtherm_preset_change(
|
||||
)
|
||||
]
|
||||
)
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
async def test_auto_start_stop_medium_heat_vtherm_preset_change_enable_false(
|
||||
hass: HomeAssistant, skip_hass_states_is_state
|
||||
):
|
||||
"""Test than auto-start/stop restart a VTherm stopped upon preset_change (in fast mode)"""
|
||||
|
||||
# vtherm_api: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api(hass)
|
||||
|
||||
# The temperatures to set
|
||||
temps = {
|
||||
"frost": 7.0,
|
||||
"eco": 17.0,
|
||||
"comfort": 19.0,
|
||||
"boost": 21.0,
|
||||
"eco_ac": 27.0,
|
||||
"comfort_ac": 25.0,
|
||||
"boost_ac": 23.0,
|
||||
"frost_away": 7.1,
|
||||
"eco_away": 17.1,
|
||||
"comfort_away": 19.1,
|
||||
"boost_away": 21.1,
|
||||
"eco_ac_away": 27.1,
|
||||
"comfort_ac_away": 25.1,
|
||||
"boost_ac_away": 23.1,
|
||||
}
|
||||
|
||||
config_entry = MockConfigEntry(
|
||||
domain=DOMAIN,
|
||||
title="TheOverClimateMockName",
|
||||
unique_id="overClimateUniqueId",
|
||||
data={
|
||||
CONF_NAME: "overClimate",
|
||||
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
|
||||
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
|
||||
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
|
||||
CONF_CYCLE_MIN: 5,
|
||||
CONF_TEMP_MIN: 15,
|
||||
CONF_TEMP_MAX: 30,
|
||||
CONF_USE_WINDOW_FEATURE: False,
|
||||
CONF_USE_MOTION_FEATURE: False,
|
||||
CONF_USE_POWER_FEATURE: False,
|
||||
CONF_USE_AUTO_START_STOP_FEATURE: True,
|
||||
CONF_USE_PRESENCE_FEATURE: True,
|
||||
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
|
||||
CONF_CLIMATE: "climate.mock_climate",
|
||||
CONF_MINIMAL_ACTIVATION_DELAY: 30,
|
||||
CONF_SECURITY_DELAY_MIN: 5,
|
||||
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
|
||||
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
|
||||
CONF_AC_MODE: True,
|
||||
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_FAST,
|
||||
},
|
||||
)
|
||||
|
||||
fake_underlying_climate = MockClimate(
|
||||
hass=hass,
|
||||
unique_id="mock_climate",
|
||||
name="mock_climate",
|
||||
hvac_modes=[HVACMode.OFF, HVACMode.COOL, HVACMode.HEAT],
|
||||
)
|
||||
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
|
||||
return_value=fake_underlying_climate,
|
||||
):
|
||||
vtherm: ThermostatOverClimate = await create_thermostat(
|
||||
hass, config_entry, "climate.overclimate"
|
||||
)
|
||||
|
||||
assert vtherm is not None
|
||||
|
||||
# Initialize all temps
|
||||
await set_all_climate_preset_temp(hass, vtherm, temps, "overclimate")
|
||||
|
||||
# Check correct initialization of auto_start_stop attributes
|
||||
assert (
|
||||
vtherm._attr_extra_state_attributes["auto_start_stop_level"]
|
||||
== AUTO_START_STOP_LEVEL_FAST
|
||||
)
|
||||
|
||||
assert vtherm._attr_extra_state_attributes["auto_start_stop_dtmin"] == 7
|
||||
|
||||
# 1. Vtherm auto-start/stop should be in FAST mode and enable should be on
|
||||
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_FAST
|
||||
enable_entity = search_entity(
|
||||
hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN
|
||||
)
|
||||
assert enable_entity is not None
|
||||
assert enable_entity.state == STATE_ON
|
||||
|
||||
assert vtherm._attr_extra_state_attributes.get("auto_start_stop_enable") is True
|
||||
|
||||
# 2. set enable to false
|
||||
enable_entity.turn_off()
|
||||
await hass.async_block_till_done()
|
||||
assert enable_entity.state == STATE_OFF
|
||||
assert vtherm._attr_extra_state_attributes.get("auto_start_stop_enable") is False
|
||||
|
||||
tz = get_tz(hass) # pylint: disable=invalid-name
|
||||
now: datetime = datetime.now(tz=tz)
|
||||
|
||||
# 3. Set mode to Heat and preset to Comfort
|
||||
await send_presence_change_event(vtherm, True, False, now)
|
||||
await send_temperature_change_event(vtherm, 16, now, True)
|
||||
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
|
||||
await vtherm.async_set_preset_mode(PRESET_ECO)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
assert vtherm.target_temperature == 17.0
|
||||
# VTherm should be heating
|
||||
assert vtherm.hvac_mode == HVACMode.HEAT
|
||||
|
||||
# 3. Set current temperature to 21 5 min later to auto-stop
|
||||
now = now + timedelta(minutes=5)
|
||||
vtherm._auto_start_stop_algo._accumulated_error = 0
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event:
|
||||
vtherm._set_now(now)
|
||||
await send_temperature_change_event(vtherm, 19, now, True)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
# VTherm should not have been stopped cause enable is false
|
||||
assert vtherm.hvac_mode == HVACMode.HEAT
|
||||
|
||||
# Not calculated cause enable = false
|
||||
assert vtherm._auto_start_stop_algo.accumulated_error == 0
|
||||
|
||||
# a message should have been sent
|
||||
assert mock_send_event.call_count == 0
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
async def test_auto_start_stop_fast_heat_window(
|
||||
hass: HomeAssistant, skip_hass_states_is_state
|
||||
):
|
||||
"""Test than auto-start/stop works with a real over_climate VTherm in FAST level and check
|
||||
interaction with window openess detection"""
|
||||
|
||||
# The temperatures to set
|
||||
temps = {
|
||||
"frost": 7.0,
|
||||
"eco": 17.0,
|
||||
"comfort": 19.0,
|
||||
"boost": 21.0,
|
||||
"eco_ac": 27.0,
|
||||
"comfort_ac": 25.0,
|
||||
"boost_ac": 23.0,
|
||||
"frost_away": 7.1,
|
||||
"eco_away": 17.1,
|
||||
"comfort_away": 19.1,
|
||||
"boost_away": 21.1,
|
||||
"eco_ac_away": 27.1,
|
||||
"comfort_ac_away": 25.1,
|
||||
"boost_ac_away": 23.1,
|
||||
}
|
||||
|
||||
config_entry = MockConfigEntry(
|
||||
domain=DOMAIN,
|
||||
title="TheOverClimateMockName",
|
||||
unique_id="overClimateUniqueId",
|
||||
data={
|
||||
CONF_NAME: "overClimate",
|
||||
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
|
||||
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
|
||||
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
|
||||
CONF_CYCLE_MIN: 5,
|
||||
CONF_TEMP_MIN: 15,
|
||||
CONF_TEMP_MAX: 30,
|
||||
CONF_USE_WINDOW_FEATURE: True,
|
||||
CONF_WINDOW_SENSOR: "binary_sensor.window_sensor",
|
||||
CONF_WINDOW_DELAY: 10,
|
||||
CONF_USE_MOTION_FEATURE: False,
|
||||
CONF_USE_POWER_FEATURE: False,
|
||||
CONF_USE_AUTO_START_STOP_FEATURE: True,
|
||||
CONF_USE_PRESENCE_FEATURE: True,
|
||||
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
|
||||
CONF_CLIMATE: "climate.mock_climate",
|
||||
CONF_MINIMAL_ACTIVATION_DELAY: 30,
|
||||
CONF_SECURITY_DELAY_MIN: 5,
|
||||
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
|
||||
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
|
||||
CONF_AC_MODE: True,
|
||||
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_FAST,
|
||||
},
|
||||
)
|
||||
|
||||
fake_underlying_climate = MockClimate(
|
||||
hass=hass,
|
||||
unique_id="mock_climate",
|
||||
name="mock_climate",
|
||||
hvac_modes=[HVACMode.OFF, HVACMode.COOL, HVACMode.HEAT],
|
||||
)
|
||||
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
|
||||
return_value=fake_underlying_climate,
|
||||
):
|
||||
vtherm: ThermostatOverClimate = await create_thermostat(
|
||||
hass, config_entry, "climate.overclimate"
|
||||
)
|
||||
|
||||
assert vtherm is not None
|
||||
|
||||
# Initialize all temps
|
||||
await set_all_climate_preset_temp(hass, vtherm, temps, "overclimate")
|
||||
|
||||
# Check correct initialization of auto_start_stop attributes
|
||||
assert (
|
||||
vtherm._attr_extra_state_attributes["auto_start_stop_level"]
|
||||
== AUTO_START_STOP_LEVEL_FAST
|
||||
)
|
||||
|
||||
assert vtherm._attr_extra_state_attributes["auto_start_stop_dtmin"] == 7
|
||||
|
||||
# 1. Vtherm auto-start/stop should be in MEDIUM mode and an enable entity should exists
|
||||
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_FAST
|
||||
enable_entity = search_entity(
|
||||
hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN
|
||||
)
|
||||
assert enable_entity is not None
|
||||
assert enable_entity.state == STATE_ON
|
||||
|
||||
tz = get_tz(hass) # pylint: disable=invalid-name
|
||||
now: datetime = datetime.now(tz=tz)
|
||||
|
||||
# 2. Set mode to Heat and preset to Comfort and close the window
|
||||
send_window_change_event(vtherm, False, False, now, False)
|
||||
await send_presence_change_event(vtherm, True, False, now)
|
||||
await send_temperature_change_event(vtherm, 18, now, True)
|
||||
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
|
||||
await vtherm.async_set_preset_mode(PRESET_COMFORT)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
assert vtherm.target_temperature == 19.0
|
||||
# VTherm should be heating
|
||||
assert vtherm.hvac_mode == HVACMode.HEAT
|
||||
# VTherm window_state should be off
|
||||
assert vtherm.window_state == STATE_OFF
|
||||
|
||||
# 3. Set current temperature to 21 5 min later -> should turn off VTherm
|
||||
now = now + timedelta(minutes=5)
|
||||
# reset accumulated error (only for testing)
|
||||
vtherm._auto_start_stop_algo._accumulated_error = 0
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event:
|
||||
vtherm._set_now(now)
|
||||
await send_temperature_change_event(vtherm, 21, now, True)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
# VTherm should no more be heating
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason == HVAC_OFF_REASON_AUTO_START_STOP
|
||||
assert vtherm._saved_hvac_mode == HVACMode.HEAT
|
||||
assert mock_send_event.call_count == 2
|
||||
|
||||
# 4. Open the window and wait for the delay
|
||||
now = now + timedelta(minutes=2)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"homeassistant.helpers.condition.state", return_value=True
|
||||
) as mock_condition:
|
||||
vtherm._set_now(now)
|
||||
try_function = await send_window_change_event(
|
||||
vtherm, True, False, now, sleep=False
|
||||
)
|
||||
|
||||
await try_function(None)
|
||||
|
||||
# Nothing should have change (window event is ignoed as we are already OFF)
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason == HVAC_OFF_REASON_AUTO_START_STOP
|
||||
assert vtherm._saved_hvac_mode == HVACMode.HEAT
|
||||
|
||||
mock_send_event.assert_not_called()
|
||||
|
||||
assert vtherm.window_state == STATE_ON
|
||||
|
||||
# 5. close the window
|
||||
now = now + timedelta(minutes=2)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"homeassistant.helpers.condition.state", return_value=True
|
||||
) as mock_condition:
|
||||
vtherm._set_now(now)
|
||||
try_function = await send_window_change_event(
|
||||
vtherm, False, True, now, sleep=False
|
||||
)
|
||||
|
||||
await try_function(None)
|
||||
|
||||
# The VTherm should stay off because the reason of off is auto-start-stop
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason == HVAC_OFF_REASON_AUTO_START_STOP
|
||||
assert vtherm._saved_hvac_mode == HVACMode.HEAT
|
||||
|
||||
assert mock_send_event.call_count == 0
|
||||
|
||||
assert vtherm.window_state == STATE_OFF
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
async def test_auto_start_stop_fast_heat_window_mixed(
|
||||
hass: HomeAssistant, skip_hass_states_is_state
|
||||
):
|
||||
"""Test than auto-start/stop works with a real over_climate VTherm in FAST level and check
|
||||
interaction with window openess detection
|
||||
The case is when first window on, then auto-stop, then window off and then auto-start
|
||||
"""
|
||||
|
||||
# The temperatures to set
|
||||
temps = {
|
||||
"frost": 7.0,
|
||||
"eco": 17.0,
|
||||
"comfort": 19.0,
|
||||
"boost": 21.0,
|
||||
"eco_ac": 27.0,
|
||||
"comfort_ac": 25.0,
|
||||
"boost_ac": 23.0,
|
||||
"frost_away": 7.1,
|
||||
"eco_away": 17.1,
|
||||
"comfort_away": 19.1,
|
||||
"boost_away": 21.1,
|
||||
"eco_ac_away": 27.1,
|
||||
"comfort_ac_away": 25.1,
|
||||
"boost_ac_away": 23.1,
|
||||
}
|
||||
|
||||
config_entry = MockConfigEntry(
|
||||
domain=DOMAIN,
|
||||
title="TheOverClimateMockName",
|
||||
unique_id="overClimateUniqueId",
|
||||
data={
|
||||
CONF_NAME: "overClimate",
|
||||
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
|
||||
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
|
||||
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
|
||||
CONF_CYCLE_MIN: 5,
|
||||
CONF_TEMP_MIN: 15,
|
||||
CONF_TEMP_MAX: 30,
|
||||
CONF_USE_WINDOW_FEATURE: True,
|
||||
CONF_WINDOW_SENSOR: "binary_sensor.window_sensor",
|
||||
CONF_WINDOW_DELAY: 10,
|
||||
CONF_USE_MOTION_FEATURE: False,
|
||||
CONF_USE_POWER_FEATURE: False,
|
||||
CONF_USE_AUTO_START_STOP_FEATURE: True,
|
||||
CONF_USE_PRESENCE_FEATURE: True,
|
||||
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
|
||||
CONF_CLIMATE: "climate.mock_climate",
|
||||
CONF_MINIMAL_ACTIVATION_DELAY: 30,
|
||||
CONF_SECURITY_DELAY_MIN: 5,
|
||||
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
|
||||
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
|
||||
CONF_AC_MODE: True,
|
||||
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_FAST,
|
||||
},
|
||||
)
|
||||
|
||||
fake_underlying_climate = MockClimate(
|
||||
hass=hass,
|
||||
unique_id="mock_climate",
|
||||
name="mock_climate",
|
||||
hvac_modes=[HVACMode.OFF, HVACMode.COOL, HVACMode.HEAT],
|
||||
)
|
||||
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
|
||||
return_value=fake_underlying_climate,
|
||||
):
|
||||
vtherm: ThermostatOverClimate = await create_thermostat(
|
||||
hass, config_entry, "climate.overclimate"
|
||||
)
|
||||
|
||||
assert vtherm is not None
|
||||
|
||||
# Initialize all temps
|
||||
await set_all_climate_preset_temp(hass, vtherm, temps, "overclimate")
|
||||
|
||||
# Check correct initialization of auto_start_stop attributes
|
||||
assert (
|
||||
vtherm._attr_extra_state_attributes["auto_start_stop_level"]
|
||||
== AUTO_START_STOP_LEVEL_FAST
|
||||
)
|
||||
|
||||
assert vtherm._attr_extra_state_attributes["auto_start_stop_dtmin"] == 7
|
||||
|
||||
# 1. Vtherm auto-start/stop should be in MEDIUM mode and an enable entity should exists
|
||||
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_FAST
|
||||
enable_entity = search_entity(
|
||||
hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN
|
||||
)
|
||||
assert enable_entity is not None
|
||||
assert enable_entity.state == STATE_ON
|
||||
|
||||
tz = get_tz(hass) # pylint: disable=invalid-name
|
||||
now: datetime = datetime.now(tz=tz)
|
||||
|
||||
# 2. Set mode to Heat and preset to Comfort and close the window
|
||||
send_window_change_event(vtherm, False, False, now, False)
|
||||
await send_presence_change_event(vtherm, True, False, now)
|
||||
await send_temperature_change_event(vtherm, 18, now, True)
|
||||
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
|
||||
await vtherm.async_set_preset_mode(PRESET_COMFORT)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
assert vtherm.target_temperature == 19.0
|
||||
# VTherm should be heating
|
||||
assert vtherm.hvac_mode == HVACMode.HEAT
|
||||
# VTherm window_state should be off
|
||||
assert vtherm.window_state == STATE_OFF
|
||||
|
||||
# 3. Open the window and wait for the delay
|
||||
now = now + timedelta(minutes=2)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"homeassistant.helpers.condition.state", return_value=True
|
||||
) as mock_condition:
|
||||
vtherm._set_now(now)
|
||||
try_function = await send_window_change_event(
|
||||
vtherm, True, False, now, sleep=False
|
||||
)
|
||||
|
||||
await try_function(None)
|
||||
|
||||
# Nothing should have change (window event is ignoed as we are already OFF)
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason == HVAC_OFF_REASON_WINDOW_DETECTION
|
||||
assert vtherm._saved_hvac_mode == HVACMode.HEAT
|
||||
|
||||
assert mock_send_event.call_count == 2
|
||||
|
||||
assert vtherm.window_state == STATE_ON
|
||||
|
||||
# 4. Set current temperature to 21 5 min later -> should turn off VTherm
|
||||
now = now + timedelta(minutes=5)
|
||||
# reset accumulated error (only for testing)
|
||||
vtherm._auto_start_stop_algo._accumulated_error = 0
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event:
|
||||
vtherm._set_now(now)
|
||||
await send_temperature_change_event(vtherm, 21, now, True)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
# VTherm should no more be heating
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason == HVAC_OFF_REASON_WINDOW_DETECTION # No change
|
||||
assert vtherm._saved_hvac_mode == HVACMode.HEAT
|
||||
assert mock_send_event.call_count == 0 # No message
|
||||
|
||||
# 5. close the window
|
||||
now = now + timedelta(minutes=2)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"homeassistant.helpers.condition.state", return_value=True
|
||||
) as mock_condition:
|
||||
vtherm._set_now(now)
|
||||
try_function = await send_window_change_event(
|
||||
vtherm, False, True, now, sleep=False
|
||||
)
|
||||
|
||||
await try_function(None)
|
||||
|
||||
# The VTherm should turn on and off again due to auto-start-stop
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason is HVAC_OFF_REASON_AUTO_START_STOP
|
||||
assert vtherm._saved_hvac_mode == HVACMode.HEAT
|
||||
|
||||
assert vtherm.window_state == STATE_OFF
|
||||
assert mock_send_event.call_count >= 2
|
||||
mock_send_event.assert_has_calls(
|
||||
[
|
||||
call(EventType.HVAC_MODE_EVENT, {"hvac_mode": HVACMode.OFF}),
|
||||
call(
|
||||
event_type=EventType.AUTO_START_STOP_EVENT,
|
||||
data={
|
||||
"type": "stop",
|
||||
"name": "overClimate",
|
||||
"cause": "Auto stop conditions reached",
|
||||
"hvac_mode": HVACMode.OFF,
|
||||
"saved_hvac_mode": HVACMode.HEAT,
|
||||
"target_temperature": 19.0,
|
||||
"current_temperature": 21.0,
|
||||
"temperature_slope": 0.214,
|
||||
"accumulated_error": -2,
|
||||
"accumulated_error_threshold": 2,
|
||||
},
|
||||
),
|
||||
]
|
||||
)
|
||||
|
||||
@@ -630,6 +630,7 @@ async def test_climate_ac_only_change_central_mode_true(
|
||||
},
|
||||
)
|
||||
|
||||
# 1. set hvac_mode to COOL and preet ECO
|
||||
with patch("homeassistant.core.ServiceRegistry.async_call"), patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
|
||||
return_value=fake_underlying_climate,
|
||||
@@ -982,7 +983,8 @@ async def test_switch_change_central_mode_true_with_cool_only_and_window(
|
||||
await select_entity.async_select_option(CENTRAL_MODE_COOL_ONLY)
|
||||
|
||||
assert entity.last_central_mode is CENTRAL_MODE_COOL_ONLY
|
||||
await entity.async_set_hvac_mode(HVACMode.OFF)
|
||||
assert entity.hvac_mode is HVACMode.OFF
|
||||
assert entity.hvac_off_reason == HVAC_OFF_REASON_MANUAL
|
||||
await entity.async_set_preset_mode(PRESET_ACTIVITY)
|
||||
assert entity._saved_hvac_mode == HVACMode.HEAT
|
||||
assert entity._saved_preset_mode == PRESET_ACTIVITY
|
||||
@@ -1000,12 +1002,14 @@ async def test_switch_change_central_mode_true_with_cool_only_and_window(
|
||||
|
||||
await try_function(None)
|
||||
|
||||
assert mock_send_event.call_count == 1
|
||||
mock_send_event.assert_has_calls(
|
||||
[call.send_event(EventType.HVAC_MODE_EVENT, {"hvac_mode": HVACMode.OFF})]
|
||||
)
|
||||
# The VTherm is already off -> window detection is ignored
|
||||
assert mock_send_event.call_count == 0
|
||||
# mock_send_event.assert_has_calls(
|
||||
# [call.send_event(EventType.HVAC_MODE_EVENT, {"hvac_mode": HVACMode.OFF})]
|
||||
# )
|
||||
|
||||
assert entity.hvac_mode == HVACMode.OFF
|
||||
assert entity.hvac_off_reason == HVAC_OFF_REASON_MANUAL
|
||||
assert entity.preset_mode == PRESET_ACTIVITY
|
||||
assert entity._saved_hvac_mode == HVACMode.HEAT
|
||||
assert entity._saved_preset_mode == PRESET_ACTIVITY
|
||||
@@ -1021,6 +1025,8 @@ async def test_switch_change_central_mode_true_with_cool_only_and_window(
|
||||
assert entity.last_central_mode is CENTRAL_MODE_AUTO
|
||||
# No change
|
||||
assert entity.hvac_mode == HVACMode.OFF
|
||||
# We have to a reason of WINDOW_DETECTION
|
||||
assert entity.hvac_off_reason == HVAC_OFF_REASON_WINDOW_DETECTION
|
||||
assert entity.preset_mode == PRESET_ACTIVITY
|
||||
assert entity._saved_hvac_mode == HVACMode.HEAT
|
||||
assert entity._saved_preset_mode == PRESET_ACTIVITY
|
||||
@@ -1046,6 +1052,7 @@ async def test_switch_change_central_mode_true_with_cool_only_and_window(
|
||||
|
||||
# We should stay off because central is STOPPED
|
||||
assert entity.hvac_mode == HVACMode.HEAT
|
||||
assert entity.hvac_off_reason is None
|
||||
assert entity.preset_mode == PRESET_ACTIVITY
|
||||
assert entity._saved_hvac_mode == HVACMode.HEAT
|
||||
assert entity._saved_preset_mode == PRESET_ACTIVITY
|
||||
|
||||
File diff suppressed because it is too large
Load Diff
@@ -11,6 +11,8 @@ from homeassistant.components.climate import (
|
||||
SERVICE_SET_TEMPERATURE,
|
||||
)
|
||||
|
||||
from homeassistant.components.switch import DOMAIN as SWITCH_DOMAIN
|
||||
|
||||
from custom_components.versatile_thermostat.thermostat_climate import (
|
||||
ThermostatOverClimate,
|
||||
)
|
||||
@@ -320,6 +322,78 @@ async def test_bug_101(
|
||||
assert entity.preset_mode is PRESET_NONE
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
async def test_bug_615(
|
||||
hass: HomeAssistant,
|
||||
skip_hass_states_is_state,
|
||||
skip_turn_on_off_heater,
|
||||
skip_send_event,
|
||||
):
|
||||
"""Test that when a underlying climate target temp is changed, the VTherm don't change its own temperature target if no
|
||||
target_temperature have already been sent"""
|
||||
|
||||
tz = get_tz(hass) # pylint: disable=invalid-name
|
||||
now: datetime = datetime.now(tz=tz)
|
||||
|
||||
entry = MockConfigEntry(
|
||||
domain=DOMAIN,
|
||||
title="TheOverClimateMockName",
|
||||
unique_id="uniqueId",
|
||||
data=PARTIAL_CLIMATE_NOT_REGULATED_CONFIG, # 5 minutes security delay
|
||||
)
|
||||
|
||||
# Underlying is in HEAT mode but should be shutdown at startup
|
||||
fake_underlying_climate = MockClimate(
|
||||
hass, "mockUniqueId", "MockClimateName", {}, HVACMode.HEAT, HVACAction.HEATING
|
||||
)
|
||||
|
||||
# 1. create the thermostat
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
), patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
|
||||
return_value=fake_underlying_climate,
|
||||
):
|
||||
vtherm = await create_thermostat(hass, entry, "climate.theoverclimatemockname")
|
||||
|
||||
assert vtherm
|
||||
|
||||
assert vtherm.name == "TheOverClimateMockName"
|
||||
assert vtherm.is_over_climate is True
|
||||
assert vtherm.hvac_mode is HVACMode.OFF
|
||||
# because in MockClimate HVACAction is HEATING if hvac_mode is not set
|
||||
assert vtherm.hvac_action is HVACAction.HEATING
|
||||
|
||||
# Force a preset_mode without sending a temperature (as it was restored with a preset)
|
||||
vtherm._attr_preset_mode = PRESET_BOOST
|
||||
|
||||
assert vtherm.target_temperature == vtherm.min_temp
|
||||
assert vtherm.preset_mode is PRESET_BOOST
|
||||
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.set_hvac_mode"
|
||||
) as mock_underlying_set_hvac_mode:
|
||||
# 2. Change the target temp of underlying thermostat at now + 1 min
|
||||
now = now + timedelta(minutes=1)
|
||||
await send_climate_change_event_with_temperature(
|
||||
vtherm,
|
||||
HVACMode.OFF,
|
||||
HVACMode.OFF,
|
||||
HVACAction.OFF,
|
||||
HVACAction.OFF,
|
||||
now,
|
||||
25,
|
||||
True,
|
||||
"climate.mock_climate", # the underlying climate entity id
|
||||
)
|
||||
# Should NOT have been taken the new target temp nor have change the preset
|
||||
assert vtherm.target_temperature == vtherm.min_temp
|
||||
assert vtherm.preset_mode is PRESET_BOOST
|
||||
|
||||
mock_underlying_set_hvac_mode.assert_not_called()
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
async def test_bug_508(
|
||||
hass: HomeAssistant,
|
||||
@@ -631,3 +705,356 @@ async def test_ignore_temp_outside_minmax_range(
|
||||
"climate.mock_climate", # the underlying climate entity id
|
||||
)
|
||||
assert entity.target_temperature == 17
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
async def test_manual_hvac_off_should_take_the_lead_over_window(
|
||||
hass: HomeAssistant, skip_hass_states_is_state
|
||||
):
|
||||
"""Test than a manual hvac_off is taken into account over a window hvac_off"""
|
||||
|
||||
# The temperatures to set
|
||||
temps = {
|
||||
"frost": 7.0,
|
||||
"eco": 17.0,
|
||||
"comfort": 19.0,
|
||||
"boost": 21.0,
|
||||
"eco_ac": 27.0,
|
||||
"comfort_ac": 25.0,
|
||||
"boost_ac": 23.0,
|
||||
"frost_away": 7.1,
|
||||
"eco_away": 17.1,
|
||||
"comfort_away": 19.1,
|
||||
"boost_away": 21.1,
|
||||
"eco_ac_away": 27.1,
|
||||
"comfort_ac_away": 25.1,
|
||||
"boost_ac_away": 23.1,
|
||||
}
|
||||
|
||||
config_entry = MockConfigEntry(
|
||||
domain=DOMAIN,
|
||||
title="TheOverClimateMockName",
|
||||
unique_id="overClimateUniqueId",
|
||||
data={
|
||||
CONF_NAME: "overClimate",
|
||||
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
|
||||
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
|
||||
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
|
||||
CONF_CYCLE_MIN: 5,
|
||||
CONF_TEMP_MIN: 15,
|
||||
CONF_TEMP_MAX: 30,
|
||||
CONF_USE_WINDOW_FEATURE: True,
|
||||
CONF_WINDOW_SENSOR: "binary_sensor.window_sensor",
|
||||
CONF_WINDOW_DELAY: 10,
|
||||
CONF_USE_MOTION_FEATURE: False,
|
||||
CONF_USE_POWER_FEATURE: False,
|
||||
CONF_USE_AUTO_START_STOP_FEATURE: True,
|
||||
CONF_USE_PRESENCE_FEATURE: True,
|
||||
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
|
||||
CONF_CLIMATE: "climate.mock_climate",
|
||||
CONF_MINIMAL_ACTIVATION_DELAY: 30,
|
||||
CONF_SECURITY_DELAY_MIN: 5,
|
||||
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
|
||||
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
|
||||
CONF_AC_MODE: True,
|
||||
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_FAST,
|
||||
},
|
||||
)
|
||||
|
||||
fake_underlying_climate = MockClimate(
|
||||
hass=hass,
|
||||
unique_id="mock_climate",
|
||||
name="mock_climate",
|
||||
hvac_modes=[HVACMode.OFF, HVACMode.COOL, HVACMode.HEAT],
|
||||
)
|
||||
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
|
||||
return_value=fake_underlying_climate,
|
||||
):
|
||||
vtherm: ThermostatOverClimate = await create_thermostat(
|
||||
hass, config_entry, "climate.overclimate"
|
||||
)
|
||||
|
||||
assert vtherm is not None
|
||||
|
||||
# Initialize all temps
|
||||
await set_all_climate_preset_temp(hass, vtherm, temps, "overclimate")
|
||||
|
||||
# Check correct initialization of auto_start_stop attributes
|
||||
assert (
|
||||
vtherm._attr_extra_state_attributes["auto_start_stop_level"]
|
||||
== AUTO_START_STOP_LEVEL_FAST
|
||||
)
|
||||
|
||||
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_FAST
|
||||
enable_entity = search_entity(
|
||||
hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN
|
||||
)
|
||||
assert enable_entity is not None
|
||||
assert enable_entity.state == STATE_ON
|
||||
|
||||
tz = get_tz(hass) # pylint: disable=invalid-name
|
||||
now: datetime = datetime.now(tz=tz)
|
||||
|
||||
# 1. Set mode to Heat and preset to Comfort and close the window
|
||||
send_window_change_event(vtherm, False, False, now, False)
|
||||
await send_presence_change_event(vtherm, True, False, now)
|
||||
await send_temperature_change_event(vtherm, 18, now, True)
|
||||
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
|
||||
await vtherm.async_set_preset_mode(PRESET_COMFORT)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
assert vtherm.target_temperature == 19.0
|
||||
# VTherm should be heating
|
||||
assert vtherm.hvac_mode == HVACMode.HEAT
|
||||
# VTherm window_state should be off
|
||||
assert vtherm.window_state == STATE_OFF
|
||||
|
||||
# 2. Open the window and wait for the delay
|
||||
now = now + timedelta(minutes=2)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"homeassistant.helpers.condition.state", return_value=True
|
||||
):
|
||||
vtherm._set_now(now)
|
||||
try_function = await send_window_change_event(
|
||||
vtherm, True, False, now, sleep=False
|
||||
)
|
||||
|
||||
await try_function(None)
|
||||
|
||||
# Nothing should have change (window event is ignoed as we are already OFF)
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason == HVAC_OFF_REASON_WINDOW_DETECTION
|
||||
assert vtherm._saved_hvac_mode == HVACMode.HEAT
|
||||
|
||||
assert mock_send_event.call_count == 2
|
||||
|
||||
assert vtherm.window_state == STATE_ON
|
||||
|
||||
# 3. Turn off manually the VTherm. This should be taken into account
|
||||
now = now + timedelta(minutes=1)
|
||||
vtherm._set_now(now)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event:
|
||||
await vtherm.async_set_hvac_mode(HVACMode.OFF)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
# Should be off with reason MANUAL
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason == HVAC_OFF_REASON_MANUAL
|
||||
assert vtherm._saved_hvac_mode == HVACMode.OFF
|
||||
# Window state should not change
|
||||
assert vtherm.window_state == STATE_ON
|
||||
|
||||
assert mock_send_event.call_count == 1
|
||||
mock_send_event.assert_has_calls(
|
||||
[
|
||||
call(EventType.HVAC_MODE_EVENT, {"hvac_mode": HVACMode.OFF}),
|
||||
]
|
||||
)
|
||||
|
||||
# 4. close the window -> we should stay off reason manual
|
||||
now = now + timedelta(minutes=1)
|
||||
vtherm._set_now(now)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"homeassistant.helpers.condition.state", return_value=True
|
||||
):
|
||||
try_function = await send_window_change_event(
|
||||
vtherm, False, True, now, sleep=False
|
||||
)
|
||||
|
||||
await try_function(None)
|
||||
|
||||
# The VTherm should turn on and off again due to auto-start-stop
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason is HVAC_OFF_REASON_MANUAL
|
||||
assert vtherm._saved_hvac_mode == HVACMode.OFF
|
||||
|
||||
assert vtherm.window_state == STATE_OFF
|
||||
assert mock_send_event.call_count == 0
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
async def test_manual_hvac_off_should_take_the_lead_over_auto_start_stop(
|
||||
hass: HomeAssistant, skip_hass_states_is_state
|
||||
):
|
||||
"""Test than a manual hvac_off is taken into account over a auto-start/stop hvac_off"""
|
||||
|
||||
# The temperatures to set
|
||||
temps = {
|
||||
"frost": 7.0,
|
||||
"eco": 17.0,
|
||||
"comfort": 19.0,
|
||||
"boost": 21.0,
|
||||
"eco_ac": 27.0,
|
||||
"comfort_ac": 25.0,
|
||||
"boost_ac": 23.0,
|
||||
"frost_away": 7.1,
|
||||
"eco_away": 17.1,
|
||||
"comfort_away": 19.1,
|
||||
"boost_away": 21.1,
|
||||
"eco_ac_away": 27.1,
|
||||
"comfort_ac_away": 25.1,
|
||||
"boost_ac_away": 23.1,
|
||||
}
|
||||
|
||||
config_entry = MockConfigEntry(
|
||||
domain=DOMAIN,
|
||||
title="TheOverClimateMockName",
|
||||
unique_id="overClimateUniqueId",
|
||||
data={
|
||||
CONF_NAME: "overClimate",
|
||||
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
|
||||
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
|
||||
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
|
||||
CONF_CYCLE_MIN: 5,
|
||||
CONF_TEMP_MIN: 15,
|
||||
CONF_TEMP_MAX: 30,
|
||||
CONF_USE_WINDOW_FEATURE: True,
|
||||
CONF_WINDOW_SENSOR: "binary_sensor.window_sensor",
|
||||
CONF_WINDOW_DELAY: 10,
|
||||
CONF_USE_MOTION_FEATURE: False,
|
||||
CONF_USE_POWER_FEATURE: False,
|
||||
CONF_USE_AUTO_START_STOP_FEATURE: True,
|
||||
CONF_USE_PRESENCE_FEATURE: True,
|
||||
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
|
||||
CONF_CLIMATE: "climate.mock_climate",
|
||||
CONF_MINIMAL_ACTIVATION_DELAY: 30,
|
||||
CONF_SECURITY_DELAY_MIN: 5,
|
||||
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
|
||||
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
|
||||
CONF_AC_MODE: True,
|
||||
CONF_AUTO_START_STOP_LEVEL: AUTO_START_STOP_LEVEL_FAST,
|
||||
},
|
||||
)
|
||||
|
||||
fake_underlying_climate = MockClimate(
|
||||
hass=hass,
|
||||
unique_id="mock_climate",
|
||||
name="mock_climate",
|
||||
hvac_modes=[HVACMode.OFF, HVACMode.COOL, HVACMode.HEAT],
|
||||
)
|
||||
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
|
||||
return_value=fake_underlying_climate,
|
||||
):
|
||||
vtherm: ThermostatOverClimate = await create_thermostat(
|
||||
hass, config_entry, "climate.overclimate"
|
||||
)
|
||||
|
||||
assert vtherm is not None
|
||||
|
||||
# Initialize all temps
|
||||
await set_all_climate_preset_temp(hass, vtherm, temps, "overclimate")
|
||||
|
||||
# Check correct initialization of auto_start_stop attributes
|
||||
assert (
|
||||
vtherm._attr_extra_state_attributes["auto_start_stop_level"]
|
||||
== AUTO_START_STOP_LEVEL_FAST
|
||||
)
|
||||
|
||||
assert vtherm.auto_start_stop_level == AUTO_START_STOP_LEVEL_FAST
|
||||
enable_entity = search_entity(
|
||||
hass, "switch.overclimate_enable_auto_start_stop", SWITCH_DOMAIN
|
||||
)
|
||||
assert enable_entity is not None
|
||||
assert enable_entity.state == STATE_ON
|
||||
|
||||
tz = get_tz(hass) # pylint: disable=invalid-name
|
||||
now: datetime = datetime.now(tz=tz)
|
||||
|
||||
# 1. Set mode to Heat and preset to Comfort
|
||||
send_window_change_event(vtherm, False, False, now, False)
|
||||
await send_presence_change_event(vtherm, True, False, now)
|
||||
await send_temperature_change_event(vtherm, 18, now, True)
|
||||
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
|
||||
await vtherm.async_set_preset_mode(PRESET_COMFORT)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
assert vtherm.target_temperature == 19.0
|
||||
# VTherm should be heating
|
||||
assert vtherm.hvac_mode == HVACMode.HEAT
|
||||
|
||||
# 2. Set current temperature to 21 5 min later -> should turn off VTherm
|
||||
now = now + timedelta(minutes=5)
|
||||
vtherm._set_now(now)
|
||||
# reset accumulated error (only for testing)
|
||||
vtherm._auto_start_stop_algo._accumulated_error = 0
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event:
|
||||
await send_temperature_change_event(vtherm, 21, now, True)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
# VTherm should no more be heating
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason == HVAC_OFF_REASON_AUTO_START_STOP
|
||||
assert vtherm._saved_hvac_mode == HVACMode.HEAT
|
||||
assert mock_send_event.call_count == 2 # turned to off
|
||||
|
||||
mock_send_event.assert_has_calls(
|
||||
[
|
||||
call(EventType.HVAC_MODE_EVENT, {"hvac_mode": HVACMode.OFF}),
|
||||
call(
|
||||
event_type=EventType.AUTO_START_STOP_EVENT,
|
||||
data={
|
||||
"type": "stop",
|
||||
"name": "overClimate",
|
||||
"cause": "Auto stop conditions reached",
|
||||
"hvac_mode": HVACMode.OFF,
|
||||
"saved_hvac_mode": HVACMode.HEAT,
|
||||
"target_temperature": 19.0,
|
||||
"current_temperature": 21.0,
|
||||
"temperature_slope": 0.3,
|
||||
"accumulated_error": -2,
|
||||
"accumulated_error_threshold": 2,
|
||||
},
|
||||
),
|
||||
]
|
||||
)
|
||||
|
||||
# 3. Turn off manually the VTherm. This should be taken into account
|
||||
now = now + timedelta(minutes=1)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event:
|
||||
await vtherm.async_set_hvac_mode(HVACMode.OFF)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
# Should be off with reason MANUAL
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason == HVAC_OFF_REASON_MANUAL
|
||||
assert vtherm._saved_hvac_mode == HVACMode.OFF
|
||||
|
||||
assert mock_send_event.call_count == 1
|
||||
mock_send_event.assert_has_calls(
|
||||
[
|
||||
call(EventType.HVAC_MODE_EVENT, {"hvac_mode": HVACMode.OFF}),
|
||||
]
|
||||
)
|
||||
|
||||
# 4. removes the auto-start/stop detection
|
||||
now = now + timedelta(minutes=5)
|
||||
vtherm._set_now(now)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"homeassistant.helpers.condition.state", return_value=True
|
||||
):
|
||||
await send_temperature_change_event(vtherm, 15, now, True)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
# VTherm should no more be heating
|
||||
assert vtherm.hvac_mode == HVACMode.OFF
|
||||
assert vtherm.hvac_off_reason == HVAC_OFF_REASON_MANUAL
|
||||
assert vtherm._saved_hvac_mode == HVACMode.OFF
|
||||
assert mock_send_event.call_count == 0 # nothing have change
|
||||
|
||||
@@ -205,6 +205,8 @@ async def test_window_management_time_enough(
|
||||
assert mock_heater_off.call_count == 2
|
||||
assert mock_condition.call_count == 1
|
||||
assert entity.hvac_mode is HVACMode.OFF
|
||||
assert entity._saved_hvac_mode is HVACMode.HEAT
|
||||
assert entity.hvac_off_reason == HVAC_OFF_REASON_WINDOW_DETECTION
|
||||
assert entity.window_state == STATE_ON
|
||||
|
||||
# Close the window
|
||||
@@ -242,6 +244,9 @@ async def test_window_management_time_enough(
|
||||
any_order=False,
|
||||
)
|
||||
assert entity.preset_mode is PRESET_BOOST
|
||||
assert entity.hvac_mode is HVACMode.HEAT
|
||||
assert entity._saved_hvac_mode is HVACMode.HEAT # No change
|
||||
assert entity.hvac_off_reason == None
|
||||
|
||||
# Clean the entity
|
||||
entity.remove_thermostat()
|
||||
@@ -1339,6 +1344,7 @@ async def test_window_action_fan_only(hass: HomeAssistant, skip_hass_states_is_s
|
||||
# The underlying should be in FAN_ONLY hvac_mode
|
||||
assert entity.hvac_mode is HVACMode.FAN_ONLY
|
||||
assert entity._saved_hvac_mode is HVACMode.HEAT
|
||||
assert entity.hvac_off_reason is None # Hvac is not off
|
||||
assert entity.preset_mode is PRESET_COMFORT
|
||||
|
||||
# 3. Close the window
|
||||
@@ -1357,7 +1363,7 @@ async def test_window_action_fan_only(hass: HomeAssistant, skip_hass_states_is_s
|
||||
await try_function(None)
|
||||
|
||||
# Wait for initial delay of heater
|
||||
await asyncio.sleep(0.3)
|
||||
await hass.async_block_till_done()
|
||||
|
||||
assert entity.window_state == STATE_OFF
|
||||
assert mock_send_event.call_count == 1
|
||||
@@ -1379,6 +1385,7 @@ async def test_window_action_fan_only(hass: HomeAssistant, skip_hass_states_is_s
|
||||
)
|
||||
assert entity.hvac_mode is HVACMode.HEAT
|
||||
assert entity.preset_mode is PRESET_COMFORT
|
||||
assert entity.hvac_off_reason is None
|
||||
|
||||
# Clean the entity
|
||||
entity.remove_thermostat()
|
||||
|
||||
Reference in New Issue
Block a user