@@ -11,6 +11,9 @@ from homeassistant.components.number import (
|
|
|
|
|
NumberMode,
|
|
|
|
|
NumberDeviceClass,
|
|
|
|
|
DOMAIN as NUMBER_DOMAIN,
|
|
|
|
|
DEFAULT_MAX_VALUE,
|
|
|
|
|
DEFAULT_MIN_VALUE,
|
|
|
|
|
DEFAULT_STEP,
|
|
|
|
|
)
|
|
|
|
|
from homeassistant.components.climate import (
|
|
|
|
|
PRESET_BOOST,
|
|
|
|
|
@@ -53,6 +56,7 @@ from .const import (
|
|
|
|
|
CONF_USE_PRESENCE_FEATURE,
|
|
|
|
|
CONF_USE_CENTRAL_BOILER_FEATURE,
|
|
|
|
|
overrides,
|
|
|
|
|
CONF_USE_MAIN_CENTRAL_CONFIG,
|
|
|
|
|
)
|
|
|
|
|
|
|
|
|
|
PRESET_ICON_MAPPING = {
|
|
|
|
|
@@ -341,7 +345,10 @@ class CentralConfigTemperatureNumber(
|
|
|
|
|
async def async_set_native_value(self, value: float) -> None:
|
|
|
|
|
"""The value have change from the Number Entity in UI"""
|
|
|
|
|
float_value = float(value)
|
|
|
|
|
old_value = float(self._attr_native_value)
|
|
|
|
|
old_value = (
|
|
|
|
|
None if self._attr_native_value is None else float(self._attr_native_value)
|
|
|
|
|
)
|
|
|
|
|
|
|
|
|
|
if float_value == old_value:
|
|
|
|
|
return
|
|
|
|
|
|
|
|
|
|
@@ -395,9 +402,11 @@ class TemperatureNumber( # pylint: disable=abstract-method
|
|
|
|
|
self._attr_device_class = NumberDeviceClass.TEMPERATURE
|
|
|
|
|
self._attr_native_unit_of_measurement = UnitOfTemperature.CELSIUS
|
|
|
|
|
|
|
|
|
|
self._attr_native_step = entry_infos.get(CONF_STEP_TEMPERATURE, 0.5)
|
|
|
|
|
self._attr_native_min_value = entry_infos.get(CONF_TEMP_MIN)
|
|
|
|
|
self._attr_native_max_value = entry_infos.get(CONF_TEMP_MAX)
|
|
|
|
|
self._has_central_main_attributes = entry_infos.get(
|
|
|
|
|
CONF_USE_MAIN_CENTRAL_CONFIG, False
|
|
|
|
|
)
|
|
|
|
|
|
|
|
|
|
self.init_min_max_step(entry_infos)
|
|
|
|
|
|
|
|
|
|
# Initialize the values if included into the entry_infos. This will do
|
|
|
|
|
# the temperature migration.
|
|
|
|
|
@@ -459,7 +468,9 @@ class TemperatureNumber( # pylint: disable=abstract-method
|
|
|
|
|
return
|
|
|
|
|
|
|
|
|
|
float_value = float(value)
|
|
|
|
|
old_value = float(self._attr_native_value)
|
|
|
|
|
old_value = (
|
|
|
|
|
None if self._attr_native_value is None else float(self._attr_native_value)
|
|
|
|
|
)
|
|
|
|
|
|
|
|
|
|
if float_value == old_value:
|
|
|
|
|
return
|
|
|
|
|
@@ -476,6 +487,10 @@ class TemperatureNumber( # pylint: disable=abstract-method
|
|
|
|
|
)
|
|
|
|
|
)
|
|
|
|
|
|
|
|
|
|
# We set the min, max and step from central config if relevant because it is possible that central config
|
|
|
|
|
# was not loaded at startup
|
|
|
|
|
self.init_min_max_step()
|
|
|
|
|
|
|
|
|
|
def __str__(self):
|
|
|
|
|
return f"VersatileThermostat-{self.name}"
|
|
|
|
|
|
|
|
|
|
@@ -485,3 +500,26 @@ class TemperatureNumber( # pylint: disable=abstract-method
|
|
|
|
|
if not self.my_climate:
|
|
|
|
|
return UnitOfTemperature.CELSIUS
|
|
|
|
|
return self.my_climate.temperature_unit
|
|
|
|
|
|
|
|
|
|
def init_min_max_step(self, entry_infos=None):
|
|
|
|
|
"""Initialize min, max and step value from config or from central config"""
|
|
|
|
|
if self._has_central_main_attributes:
|
|
|
|
|
vthermapi: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api()
|
|
|
|
|
central_config = vthermapi.find_central_configuration()
|
|
|
|
|
if central_config:
|
|
|
|
|
self._attr_native_step = central_config.data.get(CONF_STEP_TEMPERATURE)
|
|
|
|
|
self._attr_native_min_value = central_config.data.get(CONF_TEMP_MIN)
|
|
|
|
|
self._attr_native_max_value = central_config.data.get(CONF_TEMP_MAX)
|
|
|
|
|
|
|
|
|
|
return
|
|
|
|
|
|
|
|
|
|
if entry_infos:
|
|
|
|
|
self._attr_native_step = entry_infos.get(
|
|
|
|
|
CONF_STEP_TEMPERATURE, DEFAULT_STEP
|
|
|
|
|
)
|
|
|
|
|
self._attr_native_min_value = entry_infos.get(
|
|
|
|
|
CONF_TEMP_MIN, DEFAULT_MIN_VALUE
|
|
|
|
|
)
|
|
|
|
|
self._attr_native_max_value = entry_infos.get(
|
|
|
|
|
CONF_TEMP_MAX, DEFAULT_MAX_VALUE
|
|
|
|
|
)
|
|
|
|
|
|