Compare commits

..

4 Commits
6.0.2 ... 6.0.4

Author SHA1 Message Date
Jean-Marc Collin
9269240fe3 Release 2024-03-25 07:43:09 +00:00
Jean-Marc Collin
91ba2387b2 Persistence of boiler srv attribute 2024-03-25 07:25:42 +00:00
Jean-Marc Collin
162efb4709 [#425] - Boiler management entities are generated independently of this option selection (#426)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-03-25 08:00:08 +01:00
Paulo Ferreira de Castro
6a97622226 Expose the keep_alive_sec attribute in HASS Developer Tools - States (#381)
* Typing: Make BaseThermostat generic on the UnderlyingEntity type

* Typing: Change the type of IntervalCaller._interval_sec from int to float

This makes the IntervalCaller class more reusable.

* Keep-alive: Expose UnderlyingSwitch.keep_alive_sec as a HASS Dev Tools attribute

Also improve a keep-alive log message.
2024-03-23 11:49:09 +01:00
12 changed files with 58 additions and 24 deletions

View File

@@ -7,7 +7,7 @@ import logging
from datetime import timedelta, datetime
from types import MappingProxyType
from typing import Any
from typing import Any, TypeVar, Generic
from homeassistant.util import dt as dt_util
from homeassistant.core import (
@@ -140,6 +140,7 @@ from .ema import ExponentialMovingAverage
_LOGGER = logging.getLogger(__name__)
ConfigData = MappingProxyType[str, Any]
T = TypeVar("T", bound=UnderlyingEntity)
def get_tz(hass: HomeAssistant):
@@ -148,7 +149,7 @@ def get_tz(hass: HomeAssistant):
return dt_util.get_time_zone(hass.config.time_zone)
class BaseThermostat(ClimateEntity, RestoreEntity):
class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
"""Representation of a base class for all Versatile Thermostat device."""
_entity_component_unrecorded_attributes = (
@@ -278,7 +279,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
self._last_change_time = None
self._underlyings: list[UnderlyingEntity] = []
self._underlyings: list[T] = []
self._ema_temp = None
self._ema_algo = None

View File

@@ -39,6 +39,7 @@ from .const import (
CONF_USE_WINDOW_FEATURE,
CONF_THERMOSTAT_TYPE,
CONF_THERMOSTAT_CENTRAL_CONFIG,
CONF_USE_CENTRAL_BOILER_FEATURE,
CONF_CENTRAL_BOILER_ACTIVATION_SRV,
CONF_CENTRAL_BOILER_DEACTIVATION_SRV,
overrides,
@@ -63,10 +64,13 @@ async def async_setup_entry(
name = entry.data.get(CONF_NAME)
vt_type = entry.data.get(CONF_THERMOSTAT_TYPE)
entities = None
if vt_type == CONF_THERMOSTAT_CENTRAL_CONFIG:
entities = [
CentralBoilerBinarySensor(hass, unique_id, name, entry.data),
]
if entry.data.get(CONF_USE_CENTRAL_BOILER_FEATURE):
entities = [
CentralBoilerBinarySensor(hass, unique_id, name, entry.data),
]
else:
entities = [
SecurityBinarySensor(hass, unique_id, name, entry.data),
@@ -81,7 +85,8 @@ async def async_setup_entry(
if entry.data.get(CONF_USE_POWER_FEATURE):
entities.append(OverpoweringBinarySensor(hass, unique_id, name, entry.data))
async_add_entities(entities, True)
if entities:
async_add_entities(entities, True)
class SecurityBinarySensor(VersatileThermostatBaseEntity, BinarySensorEntity):

View File

@@ -242,6 +242,14 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
and infos.get(CONF_PRESENCE_SENSOR, None) is None
):
return False
if self._infos[CONF_USE_CENTRAL_BOILER_FEATURE] and (
not self._infos.get(CONF_CENTRAL_BOILER_ACTIVATION_SRV, False)
or len(self._infos.get(CONF_CENTRAL_BOILER_ACTIVATION_SRV)) <= 0
or not self._infos.get(CONF_CENTRAL_BOILER_DEACTIVATION_SRV, False)
or len(self._infos.get(CONF_CENTRAL_BOILER_DEACTIVATION_SRV)) <= 0
):
return False
else:
if (
infos.get(CONF_NAME) is None
@@ -857,6 +865,9 @@ class VersatileThermostatOptionsFlowHandler(
if not self._infos[CONF_USE_PRESENCE_FEATURE]:
self._infos[CONF_USE_PRESENCE_CENTRAL_CONFIG] = False
self._infos[CONF_PRESENCE_SENSOR] = None
if not self._infos[CONF_USE_CENTRAL_BOILER_FEATURE]:
self._infos[CONF_CENTRAL_BOILER_ACTIVATION_SRV] = None
self._infos[CONF_CENTRAL_BOILER_DEACTIVATION_SRV] = None
_LOGGER.info(
"Recreating entry %s due to configuration change. New config is now: %s",

View File

@@ -24,11 +24,16 @@ class IntervalCaller:
Convenience wrapper around Home Assistant's `async_track_time_interval` function.
"""
def __init__(self, hass: HomeAssistant, interval_sec: int) -> None:
def __init__(self, hass: HomeAssistant, interval_sec: float) -> None:
self._hass = hass
self._interval_sec = interval_sec
self._remove_handle: CALLBACK_TYPE | None = None
@property
def interval_sec(self) -> float:
"""Return the calling interval in seconds."""
return self._interval_sec
def cancel(self):
"""Cancel the regular calls to the action function."""
if self._remove_handle:
@@ -43,7 +48,11 @@ class IntervalCaller:
async def callback(_time: datetime):
try:
_LOGGER.debug("Calling keep-alive action")
_LOGGER.debug(
"Calling keep-alive action '%s' (%ss interval)",
action.__name__,
self._interval_sec,
)
await action()
except Exception as e: # pylint: disable=broad-exception-caught
_LOGGER.error(e)

View File

@@ -14,6 +14,6 @@
"quality_scale": "silver",
"requirements": [],
"ssdp": [],
"version": "6.0.2",
"version": "6.0.4",
"zeroconf": []
}

View File

@@ -51,6 +51,7 @@ from .const import (
CONF_USE_PRESETS_CENTRAL_CONFIG,
CONF_USE_PRESENCE_CENTRAL_CONFIG,
CONF_USE_PRESENCE_FEATURE,
CONF_USE_CENTRAL_BOILER_FEATURE,
overrides,
)
@@ -153,9 +154,10 @@ async def async_setup_entry(
# For central config only
else:
entities.append(
ActivateBoilerThresholdNumber(hass, unique_id, name, entry.data)
)
if entry.data.get(CONF_USE_CENTRAL_BOILER_FEATURE):
entities.append(
ActivateBoilerThresholdNumber(hass, unique_id, name, entry.data)
)
for preset in CONF_PRESETS_WITH_AC_VALUES:
_LOGGER.debug(
"%s - configuring Number central, AC, non AWAY for preset %s",
@@ -178,7 +180,8 @@ async def async_setup_entry(
)
)
async_add_entities(entities, True)
if len(entities) > 0:
async_add_entities(entities, True)
class ActivateBoilerThresholdNumber(

View File

@@ -79,7 +79,6 @@ async def async_setup_entry(
entities = [
NbActiveDeviceForBoilerSensor(hass, unique_id, name, entry.data)
]
async_add_entities(entities, True)
else:
entities = [
LastTemperatureSensor(hass, unique_id, name, entry.data),
@@ -108,6 +107,7 @@ async def async_setup_entry(
RegulatedTemperatureSensor(hass, unique_id, name, entry.data)
)
if entities:
async_add_entities(entities, True)

View File

@@ -58,7 +58,7 @@ from .underlyings import UnderlyingClimate
_LOGGER = logging.getLogger(__name__)
class ThermostatOverClimate(BaseThermostat):
class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
"""Representation of a base class for a Versatile Thermostat over a climate"""
_auto_regulation_mode: str | None = None

View File

@@ -27,7 +27,7 @@ from .prop_algorithm import PropAlgorithm
_LOGGER = logging.getLogger(__name__)
class ThermostatOverSwitch(BaseThermostat):
class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
"""Representation of a base class for a Versatile Thermostat over a switch."""
_entity_component_unrecorded_attributes = (
@@ -136,11 +136,11 @@ class ThermostatOverSwitch(BaseThermostat):
"""Custom attributes"""
super().update_custom_attributes()
under0: UnderlyingSwitch = self._underlyings[0]
self._attr_extra_state_attributes["is_over_switch"] = self.is_over_switch
self._attr_extra_state_attributes["is_inversed"] = self.is_inversed
self._attr_extra_state_attributes["underlying_switch_0"] = self._underlyings[
0
].entity_id
self._attr_extra_state_attributes["keep_alive_sec"] = under0.keep_alive_sec
self._attr_extra_state_attributes["underlying_switch_0"] = under0.entity_id
self._attr_extra_state_attributes["underlying_switch_1"] = (
self._underlyings[1].entity_id if len(self._underlyings) > 1 else None
)

View File

@@ -31,7 +31,7 @@ from .underlyings import UnderlyingValve
_LOGGER = logging.getLogger(__name__)
class ThermostatOverValve(BaseThermostat): # pylint: disable=abstract-method
class ThermostatOverValve(BaseThermostat[UnderlyingValve]): # pylint: disable=abstract-method
"""Representation of a class for a Versatile Thermostat over a Valve"""
_entity_component_unrecorded_attributes = (

View File

@@ -188,7 +188,7 @@ class UnderlyingSwitch(UnderlyingEntity):
thermostat: Any,
switch_entity_id: str,
initial_delay_sec: int,
keep_alive_sec: int,
keep_alive_sec: float,
) -> None:
"""Initialize the underlying switch"""
@@ -217,6 +217,11 @@ class UnderlyingSwitch(UnderlyingEntity):
"""Tells if the switch command should be inversed"""
return self._thermostat.is_inversed
@property
def keep_alive_sec(self) -> float:
"""Return the switch keep-alive interval in seconds."""
return self._keep_alive.interval_sec
@overrides
def startup(self):
super().startup()

View File

@@ -94,8 +94,8 @@ async def test_add_a_central_config(hass: HomeAssistant, skip_hass_states_is_sta
assert api.nb_active_device_for_boiler_entity is None
assert api.nb_active_device_for_boiler is None
assert api.nb_active_device_for_boiler_threshold_entity is not None
assert api.nb_active_device_for_boiler_threshold == 1 # the default value
assert api.nb_active_device_for_boiler_threshold_entity is None
assert api.nb_active_device_for_boiler_threshold is None
# @pytest.mark.parametrize("expected_lingering_tasks", [True])