Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
@@ -6,6 +6,7 @@ logger:
|
||||
custom_components.versatile_thermostat: info
|
||||
custom_components.versatile_thermostat.underlyings: info
|
||||
custom_components.versatile_thermostat.climate: info
|
||||
custom_components.versatile_thermostat.base_thermostat: debug
|
||||
|
||||
# If you need to debug uncommment the line below (doc: https://www.home-assistant.io/integrations/debugpy/)
|
||||
debugpy:
|
||||
@@ -166,6 +167,13 @@ climate:
|
||||
heater: input_boolean.fake_heater_switch3
|
||||
target_sensor: input_number.fake_temperature_sensor1
|
||||
|
||||
input_datetime:
|
||||
fake_last_seen:
|
||||
name: Last seen temp sensor
|
||||
icon: mdi:update
|
||||
has_date: true
|
||||
has_time: true
|
||||
|
||||
recorder:
|
||||
commit_interval: 1
|
||||
include:
|
||||
|
||||
@@ -68,6 +68,7 @@ from .const import (
|
||||
DEVICE_MANUFACTURER,
|
||||
CONF_POWER_SENSOR,
|
||||
CONF_TEMP_SENSOR,
|
||||
CONF_LAST_SEEN_TEMP_SENSOR,
|
||||
CONF_EXTERNAL_TEMP_SENSOR,
|
||||
CONF_MAX_POWER_SENSOR,
|
||||
CONF_WINDOW_SENSOR,
|
||||
@@ -242,6 +243,9 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
self._motion_call_cancel = None
|
||||
self._cur_temp = None
|
||||
self._ac_mode = None
|
||||
self._temp_sensor_entity_id = None
|
||||
self._last_seen_temp_sensor_entity_id = None
|
||||
self._ext_temp_sensor_entity_id = None
|
||||
self._last_ext_temperature_measure = None
|
||||
self._last_temperature_measure = None
|
||||
self._cur_ext_temp = None
|
||||
@@ -393,6 +397,9 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
|
||||
self._proportional_function = entry_infos.get(CONF_PROP_FUNCTION)
|
||||
self._temp_sensor_entity_id = entry_infos.get(CONF_TEMP_SENSOR)
|
||||
self._last_seen_temp_sensor_entity_id = entry_infos.get(
|
||||
CONF_LAST_SEEN_TEMP_SENSOR
|
||||
)
|
||||
self._ext_temp_sensor_entity_id = entry_infos.get(CONF_EXTERNAL_TEMP_SENSOR)
|
||||
self._power_sensor_entity_id = entry_infos.get(CONF_POWER_SENSOR)
|
||||
self._max_power_sensor_entity_id = entry_infos.get(CONF_MAX_POWER_SENSOR)
|
||||
@@ -574,6 +581,15 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
)
|
||||
)
|
||||
|
||||
if self._last_seen_temp_sensor_entity_id:
|
||||
self.async_on_remove(
|
||||
async_track_state_change_event(
|
||||
self.hass,
|
||||
[self._last_seen_temp_sensor_entity_id],
|
||||
self._async_last_seen_temperature_changed,
|
||||
)
|
||||
)
|
||||
|
||||
if self._ext_temp_sensor_entity_id:
|
||||
self.async_on_remove(
|
||||
async_track_state_change_event(
|
||||
@@ -1445,6 +1461,44 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
await self.async_control_heating(force=False)
|
||||
return dearm_window_auto
|
||||
|
||||
@callback
|
||||
async def _async_last_seen_temperature_changed(self, event: Event):
|
||||
"""Handle last seen temperature sensor changes."""
|
||||
new_state: State = event.data.get("new_state")
|
||||
_LOGGER.debug(
|
||||
"%s - Last seen temperature changed. Event.new_state is %s",
|
||||
self,
|
||||
new_state,
|
||||
)
|
||||
if new_state is None or new_state.state in (STATE_UNAVAILABLE, STATE_UNKNOWN):
|
||||
return
|
||||
|
||||
# try to extract the datetime (from state)
|
||||
try:
|
||||
# Convertir la chaîne au format ISO 8601 en objet datetime
|
||||
self._last_temperature_measure = self.get_last_updated_date_or_now(
|
||||
new_state
|
||||
)
|
||||
self.reset_last_change_time()
|
||||
_LOGGER.debug(
|
||||
"%s - new last_temperature_measure is now: %s",
|
||||
self,
|
||||
self._last_temperature_measure,
|
||||
)
|
||||
|
||||
# try to restart if we were in safety mode
|
||||
if self._security_state:
|
||||
await self.check_safety()
|
||||
|
||||
except ValueError as err:
|
||||
# La conversion a échoué, la chaîne n'est pas au format ISO 8601
|
||||
_LOGGER.warning(
|
||||
"%s - impossible to convert last seen datetime %s. Error is: %s",
|
||||
self,
|
||||
new_state.state,
|
||||
err,
|
||||
)
|
||||
|
||||
async def _async_ext_temperature_changed(self, event: Event):
|
||||
"""Handle external temperature opf the sensor changes."""
|
||||
new_state: State = event.data.get("new_state")
|
||||
|
||||
@@ -16,6 +16,10 @@ from homeassistant.components.input_number import (
|
||||
DOMAIN as INPUT_NUMBER_DOMAIN,
|
||||
)
|
||||
|
||||
from homeassistant.components.input_datetime import (
|
||||
DOMAIN as INPUT_DATETIME_DOMAIN,
|
||||
)
|
||||
|
||||
from homeassistant.components.person import DOMAIN as PERSON_DOMAIN
|
||||
from homeassistant.components.binary_sensor import DOMAIN as BINARY_SENSOR_DOMAIN
|
||||
|
||||
@@ -42,6 +46,11 @@ STEP_MAIN_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
vol.Required(CONF_TEMP_SENSOR): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(domain=[SENSOR_DOMAIN, INPUT_NUMBER_DOMAIN]),
|
||||
),
|
||||
vol.Optional(CONF_LAST_SEEN_TEMP_SENSOR): selector.EntitySelector(
|
||||
selector.EntitySelectorConfig(
|
||||
domain=[SENSOR_DOMAIN, INPUT_DATETIME_DOMAIN]
|
||||
),
|
||||
),
|
||||
vol.Required(CONF_CYCLE_MIN, default=5): cv.positive_int,
|
||||
vol.Optional(CONF_DEVICE_POWER, default="1"): vol.Coerce(float),
|
||||
vol.Required(CONF_USE_MAIN_CENTRAL_CONFIG, default=True): cv.boolean,
|
||||
|
||||
@@ -59,6 +59,7 @@ CONF_HEATER_3 = "heater_entity3_id"
|
||||
CONF_HEATER_4 = "heater_entity4_id"
|
||||
CONF_HEATER_KEEP_ALIVE = "heater_keep_alive"
|
||||
CONF_TEMP_SENSOR = "temperature_sensor_entity_id"
|
||||
CONF_LAST_SEEN_TEMP_SENSOR = "last_seen_temperature_sensor_entity_id"
|
||||
CONF_EXTERNAL_TEMP_SENSOR = "external_temperature_sensor_entity_id"
|
||||
CONF_POWER_SENSOR = "power_sensor_entity_id"
|
||||
CONF_MAX_POWER_SENSOR = "max_power_sensor_entity_id"
|
||||
|
||||
@@ -37,7 +37,8 @@
|
||||
"data": {
|
||||
"name": "Name",
|
||||
"thermostat_type": "Thermostat type",
|
||||
"temperature_sensor_entity_id": "Room temperature sensor entity id",
|
||||
"temperature_sensor_entity_id": "Room temperature",
|
||||
"last_seen_temperature_sensor_entity_id": "Last seen room temperature datetime",
|
||||
"external_temperature_sensor_entity_id": "Outdoor temperature sensor entity id",
|
||||
"cycle_min": "Cycle duration (minutes)",
|
||||
"temp_min": "Minimum temperature allowed",
|
||||
@@ -49,6 +50,8 @@
|
||||
"used_by_controls_central_boiler": "Used by central boiler. Check if this VTherm should have control on the central boiler"
|
||||
},
|
||||
"data_description": {
|
||||
"temperature_sensor_entity_id": "Room temperature sensor entity id",
|
||||
"last_seen_temperature_sensor_entity_id": "Last seen room temperature sensor entity id. Should be datetime sensor",
|
||||
"external_temperature_sensor_entity_id": "Outdoor temperature sensor entity id. Not used if central configuration is selected"
|
||||
}
|
||||
},
|
||||
@@ -269,7 +272,8 @@
|
||||
"data": {
|
||||
"name": "Name",
|
||||
"thermostat_type": "Thermostat type",
|
||||
"temperature_sensor_entity_id": "Room temperature sensor entity id",
|
||||
"temperature_sensor_entity_id": "Room temperature",
|
||||
"last_seen_temperature_sensor_entity_id": "Last seen room temperature datetime",
|
||||
"external_temperature_sensor_entity_id": "Outdoor temperature sensor entity id",
|
||||
"cycle_min": "Cycle duration (minutes)",
|
||||
"temp_min": "Minimum temperature allowed",
|
||||
@@ -281,6 +285,8 @@
|
||||
"used_by_controls_central_boiler": "Used by central boiler. Check if this VTherm should have control on the central boiler"
|
||||
},
|
||||
"data_description": {
|
||||
"temperature_sensor_entity_id": "Room temperature sensor entity id",
|
||||
"last_seen_temperature_sensor_entity_id": "Last seen room temperature sensor entity id. Should be datetime sensor",
|
||||
"external_temperature_sensor_entity_id": "Outdoor temperature sensor entity id. Not used if central configuration is selected"
|
||||
}
|
||||
},
|
||||
@@ -572,4 +578,4 @@
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -37,7 +37,8 @@
|
||||
"data": {
|
||||
"name": "Name",
|
||||
"thermostat_type": "Thermostat type",
|
||||
"temperature_sensor_entity_id": "Room temperature sensor entity id",
|
||||
"temperature_sensor_entity_id": "Room temperature",
|
||||
"last_seen_temperature_sensor_entity_id": "Last seen room temperature datetime",
|
||||
"external_temperature_sensor_entity_id": "Outdoor temperature sensor entity id",
|
||||
"cycle_min": "Cycle duration (minutes)",
|
||||
"temp_min": "Minimum temperature allowed",
|
||||
@@ -49,6 +50,8 @@
|
||||
"used_by_controls_central_boiler": "Used by central boiler. Check if this VTherm should have control on the central boiler"
|
||||
},
|
||||
"data_description": {
|
||||
"temperature_sensor_entity_id": "Room temperature sensor entity id",
|
||||
"last_seen_temperature_sensor_entity_id": "Last seen room temperature sensor entity id. Should be datetime sensor",
|
||||
"external_temperature_sensor_entity_id": "Outdoor temperature sensor entity id. Not used if central configuration is selected"
|
||||
}
|
||||
},
|
||||
@@ -269,7 +272,8 @@
|
||||
"data": {
|
||||
"name": "Name",
|
||||
"thermostat_type": "Thermostat type",
|
||||
"temperature_sensor_entity_id": "Room temperature sensor entity id",
|
||||
"temperature_sensor_entity_id": "Room temperature",
|
||||
"last_seen_temperature_sensor_entity_id": "Last seen room temperature datetime",
|
||||
"external_temperature_sensor_entity_id": "Outdoor temperature sensor entity id",
|
||||
"cycle_min": "Cycle duration (minutes)",
|
||||
"temp_min": "Minimum temperature allowed",
|
||||
@@ -281,6 +285,8 @@
|
||||
"used_by_controls_central_boiler": "Used by central boiler. Check if this VTherm should have control on the central boiler"
|
||||
},
|
||||
"data_description": {
|
||||
"temperature_sensor_entity_id": "Room temperature sensor entity id",
|
||||
"last_seen_temperature_sensor_entity_id": "Last seen room temperature sensor entity id. Should be datetime sensor",
|
||||
"external_temperature_sensor_entity_id": "Outdoor temperature sensor entity id. Not used if central configuration is selected"
|
||||
}
|
||||
},
|
||||
@@ -572,4 +578,4 @@
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -37,8 +37,9 @@
|
||||
"data": {
|
||||
"name": "Nom",
|
||||
"thermostat_type": "Type de thermostat",
|
||||
"temperature_sensor_entity_id": "Température sensor entity id",
|
||||
"external_temperature_sensor_entity_id": "Température exterieure sensor entity id",
|
||||
"temperature_sensor_entity_id": "Capteur de température",
|
||||
"last_seen_temperature_sensor_entity_id": "Dernière vue capteur de température",
|
||||
"external_temperature_sensor_entity_id": "Capteur de température exterieure",
|
||||
"cycle_min": "Durée du cycle (minutes)",
|
||||
"temp_min": "Température minimale permise",
|
||||
"temp_max": "Température maximale permise",
|
||||
@@ -49,7 +50,9 @@
|
||||
"used_by_controls_central_boiler": "Utilisé par la chaudière centrale. Cochez si ce VTherm doit contrôler la chaudière centrale."
|
||||
},
|
||||
"data_description": {
|
||||
"external_temperature_sensor_entity_id": "Entity id du capteur de température extérieure."
|
||||
"temperature_sensor_entity_id": "Id d'entité du capteur de température",
|
||||
"last_seen_temperature_sensor_entity_id": "Id d'entité du capteur donnant la date et heure de dernière vue capteur de température. L'état doit être au format date heure (ex: 2024-03-31T17:07:03+00:00)",
|
||||
"external_temperature_sensor_entity_id": "Entity id du capteur de température extérieure. Non utilisé si une configuration centrale est définie"
|
||||
}
|
||||
},
|
||||
"features": {
|
||||
@@ -281,19 +284,22 @@
|
||||
"data": {
|
||||
"name": "Nom",
|
||||
"thermostat_type": "Type de thermostat",
|
||||
"temperature_sensor_entity_id": "Température sensor entity id",
|
||||
"external_temperature_sensor_entity_id": "Température exterieure sensor entity id",
|
||||
"temperature_sensor_entity_id": "Capteur de température",
|
||||
"last_seen_temperature_sensor_entity_id": "Dernière vue capteur de température",
|
||||
"external_temperature_sensor_entity_id": "Capteur de température exterieure",
|
||||
"cycle_min": "Durée du cycle (minutes)",
|
||||
"temp_min": "Température minimale permise",
|
||||
"temp_max": "Température maximale permise",
|
||||
"step_temperature": "Pas de température",
|
||||
"device_power": "Puissance de l'équipement",
|
||||
"use_central_mode": "Autoriser le controle par une entity centrale ('nécessite une config. centrale`). Cochez pour autoriser le contrôle du VTherm par la liste déroulante 'central_mode' de l'entité configuration centrale.",
|
||||
"use_main_central_config": "Utiliser la configuration centrale supplémentaire. Cochez pour utiliser la configuration centrale supplémentaire (température externe, min, max, pas, ...).",
|
||||
"use_main_central_config": "Utiliser la configuration centrale supplémentaire. Cochez pour utiliser la configuration centrale supplémentaire (température externe, min, max, pas, ...)",
|
||||
"used_by_controls_central_boiler": "Utilisé par la chaudière centrale. Cochez si ce VTherm doit contrôler la chaudière centrale."
|
||||
},
|
||||
"data_description": {
|
||||
"external_temperature_sensor_entity_id": "Entity id du capteur de température extérieure. N'est pas utilisé si la configuration centrale est utilisée."
|
||||
"temperature_sensor_entity_id": "Id d'entité du capteur de température",
|
||||
"last_seen_temperature_sensor_entity_id": "Id d'entité du capteur donnant la date et heure de dernière vue capteur de température. L'état doit être au format date heure (ex: 2024-03-31T17:07:03+00:00)",
|
||||
"external_temperature_sensor_entity_id": "Entity id du capteur de température extérieure. Non utilisé si une configuration centrale est définie"
|
||||
}
|
||||
},
|
||||
"features": {
|
||||
|
||||
@@ -580,6 +580,31 @@ async def send_temperature_change_event(
|
||||
return dearm_window_auto
|
||||
|
||||
|
||||
async def send_last_seen_temperature_change_event(
|
||||
entity: BaseThermostat, date, sleep=True
|
||||
):
|
||||
"""Sending a new last seen event simulating a change on last seen temperature sensor"""
|
||||
_LOGGER.info(
|
||||
"------- Testu: sending send_last_seen_temperature_change_event, date=%s on %s",
|
||||
date,
|
||||
entity,
|
||||
)
|
||||
last_seen_event = Event(
|
||||
EVENT_STATE_CHANGED,
|
||||
{
|
||||
"new_state": State(
|
||||
entity_id=entity.entity_id,
|
||||
state=date,
|
||||
last_changed=date,
|
||||
last_updated=date,
|
||||
)
|
||||
},
|
||||
)
|
||||
await entity._async_last_seen_temperature_changed(last_seen_event)
|
||||
if sleep:
|
||||
await asyncio.sleep(0.1)
|
||||
|
||||
|
||||
async def send_ext_temperature_change_event(
|
||||
entity: BaseThermostat, new_temp, date, sleep=True
|
||||
):
|
||||
|
||||
139
tests/test_last_seen.py
Normal file
139
tests/test_last_seen.py
Normal file
@@ -0,0 +1,139 @@
|
||||
# pylint: disable=wildcard-import, unused-wildcard-import, protected-access, unused-argument, line-too-long
|
||||
|
||||
""" Test the Security featrure """
|
||||
from unittest.mock import patch, call
|
||||
from datetime import timedelta, datetime
|
||||
import logging
|
||||
|
||||
from custom_components.versatile_thermostat.thermostat_climate import (
|
||||
ThermostatOverClimate,
|
||||
)
|
||||
from custom_components.versatile_thermostat.thermostat_switch import (
|
||||
ThermostatOverSwitch,
|
||||
)
|
||||
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
|
||||
|
||||
|
||||
logging.getLogger().setLevel(logging.DEBUG)
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
async def test_last_seen_feature(hass: HomeAssistant, skip_hass_states_is_state):
|
||||
"""Test the last_ssen feature
|
||||
1. creates a thermostat and check that security is off
|
||||
2. activate security feature when date is expired
|
||||
3. change the last seen sensor
|
||||
4. check that security is off
|
||||
"""
|
||||
|
||||
tz = get_tz(hass) # pylint: disable=invalid-name
|
||||
|
||||
entry = MockConfigEntry(
|
||||
domain=DOMAIN,
|
||||
title="TheOverSwitchMockName",
|
||||
unique_id="uniqueId",
|
||||
data={
|
||||
"name": "TheOverSwitchMockName",
|
||||
"thermostat_type": "thermostat_over_switch",
|
||||
"temperature_sensor_entity_id": "sensor.mock_temp_sensor",
|
||||
"last_seen_temperature_sensor_entity_id": "sensor.mock_last_seen_temp_sensor",
|
||||
"external_temperature_sensor_entity_id": "sensor.mock_ext_temp_sensor",
|
||||
"cycle_min": 5,
|
||||
"temp_min": 15,
|
||||
"temp_max": 30,
|
||||
"frost_temp": 7,
|
||||
"eco_temp": 17,
|
||||
"comfort_temp": 18,
|
||||
"boost_temp": 19,
|
||||
"use_window_feature": False,
|
||||
"use_motion_feature": False,
|
||||
"use_power_feature": False,
|
||||
"use_presence_feature": False,
|
||||
"heater_entity_id": "switch.mock_switch",
|
||||
"proportional_function": "tpi",
|
||||
"tpi_coef_int": 0.3,
|
||||
"tpi_coef_ext": 0.01,
|
||||
"minimal_activation_delay": 30,
|
||||
"security_delay_min": 5, # 5 minutes
|
||||
"security_min_on_percent": 0.2,
|
||||
"security_default_on_percent": 0.1,
|
||||
},
|
||||
)
|
||||
|
||||
# 1. creates a thermostat and check that security is off
|
||||
now: datetime = datetime.now(tz=tz)
|
||||
entity: ThermostatOverSwitch = await create_thermostat(
|
||||
hass, entry, "climate.theoverswitchmockname"
|
||||
)
|
||||
assert entity
|
||||
|
||||
assert entity._security_state is False
|
||||
assert entity.preset_mode is not PRESET_SECURITY
|
||||
assert entity._last_ext_temperature_measure is not None
|
||||
assert entity._last_temperature_measure is not None
|
||||
assert (entity._last_temperature_measure.astimezone(tz) - now).total_seconds() < 1
|
||||
assert (
|
||||
entity._last_ext_temperature_measure.astimezone(tz) - now
|
||||
).total_seconds() < 1
|
||||
|
||||
# set a preset
|
||||
assert entity.preset_mode is PRESET_NONE
|
||||
await entity.async_set_preset_mode(PRESET_COMFORT)
|
||||
assert entity.preset_mode is PRESET_COMFORT
|
||||
|
||||
# Turn On the thermostat
|
||||
assert entity.hvac_mode == HVACMode.OFF
|
||||
await entity.async_set_hvac_mode(HVACMode.HEAT)
|
||||
assert entity.hvac_mode == HVACMode.HEAT
|
||||
|
||||
# 2. activate security feature when date is expired
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
|
||||
) as mock_heater_on:
|
||||
event_timestamp = now - timedelta(minutes=6)
|
||||
|
||||
# set temperature to 15 so that on_percent will be > security_min_on_percent (0.2)
|
||||
await send_temperature_change_event(entity, 15, event_timestamp)
|
||||
assert entity.security_state is True
|
||||
assert entity.preset_mode == PRESET_SECURITY
|
||||
|
||||
assert mock_send_event.call_count == 3
|
||||
mock_send_event.assert_has_calls(
|
||||
[
|
||||
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_SECURITY}),
|
||||
call.send_event(
|
||||
EventType.TEMPERATURE_EVENT,
|
||||
{
|
||||
"last_temperature_measure": event_timestamp.isoformat(),
|
||||
"last_ext_temperature_measure": entity._last_ext_temperature_measure.isoformat(),
|
||||
"current_temp": 15,
|
||||
"current_ext_temp": None,
|
||||
"target_temp": 18,
|
||||
},
|
||||
),
|
||||
call.send_event(
|
||||
EventType.SECURITY_EVENT,
|
||||
{
|
||||
"type": "start",
|
||||
"last_temperature_measure": event_timestamp.isoformat(),
|
||||
"last_ext_temperature_measure": entity._last_ext_temperature_measure.isoformat(),
|
||||
"current_temp": 15,
|
||||
"current_ext_temp": None,
|
||||
"target_temp": 18,
|
||||
},
|
||||
),
|
||||
],
|
||||
any_order=True,
|
||||
)
|
||||
|
||||
assert mock_heater_on.call_count == 1
|
||||
|
||||
# 3. change the last seen sensor
|
||||
event_timestamp = now - timedelta(minutes=4)
|
||||
await send_last_seen_temperature_change_event(entity, event_timestamp)
|
||||
assert entity.security_state is False
|
||||
assert entity.preset_mode is PRESET_COMFORT
|
||||
assert entity._last_temperature_measure == event_timestamp
|
||||
Reference in New Issue