Issue #846 - swicth Eco preset after Window close event (#868)

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
Jean-Marc Collin
2025-01-25 11:09:34 +01:00
committed by GitHub
parent 8cf09e5254
commit a3b6f66f1b

View File

@@ -1050,7 +1050,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
self._hvac_mode in [HVACMode.COOL, HVACMode.HEAT, HVACMode.HEAT_COOL]
and self.preset_mode != PRESET_NONE
):
if self.preset_mode != PRESET_FROST_PROTECTION:
if self.preset_mode != PRESET_FROST_PROTECTION or self._hvac_mode in [HVACMode.HEAT, HVACMode.HEAT_COOL]:
await self.async_set_preset_mode_internal(self.preset_mode, True)
else:
await self.async_set_preset_mode_internal(PRESET_ECO, True, False)