FIX issue #272 and #24ç - min and max values depending of the underlying
This commit is contained in:
@@ -4,7 +4,7 @@
|
||||
from unittest.mock import patch, call
|
||||
from datetime import datetime, timedelta
|
||||
|
||||
from homeassistant.core import HomeAssistant
|
||||
from homeassistant.core import HomeAssistant, State
|
||||
from homeassistant.components.climate import HVACAction, HVACMode
|
||||
from homeassistant.config_entries import ConfigEntryState
|
||||
|
||||
@@ -214,20 +214,60 @@ async def test_over_valve_full_start(
|
||||
assert entity.hvac_action == HVACAction.HEATING
|
||||
|
||||
# Change internal temperature
|
||||
expected_state = State(
|
||||
entity_id="number.mock_valve", state="0", attributes={"min": 10, "max": 50}
|
||||
)
|
||||
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"homeassistant.core.ServiceRegistry.async_call"
|
||||
) as mock_service_call, patch(
|
||||
"homeassistant.core.StateMachine.get", return_value=0
|
||||
"homeassistant.core.StateMachine.get", return_value=expected_state
|
||||
):
|
||||
event_timestamp = now - timedelta(minutes=3)
|
||||
await send_temperature_change_event(entity, 20, datetime.now())
|
||||
assert entity.valve_open_percent == 0
|
||||
assert entity.is_device_active is False
|
||||
assert entity.hvac_action == HVACAction.IDLE
|
||||
assert entity.is_device_active is True # Should be 0 but in fact 10 is send
|
||||
assert (
|
||||
entity.hvac_action == HVACAction.HEATING
|
||||
) # Should be IDLE but heating due to 10
|
||||
|
||||
assert mock_service_call.call_count == 1
|
||||
# The VTherm valve is 0, but the underlying have received 10 which is the min
|
||||
mock_service_call.assert_has_calls(
|
||||
[
|
||||
call.async_call(
|
||||
"number",
|
||||
"set_value",
|
||||
{"entity_id": "number.mock_valve", "value": 10},
|
||||
)
|
||||
]
|
||||
)
|
||||
|
||||
await send_temperature_change_event(entity, 17, datetime.now())
|
||||
assert mock_service_call.call_count == 2
|
||||
# The VTherm valve is 0, but the underlying have received 10 which is the min
|
||||
mock_service_call.assert_has_calls(
|
||||
[
|
||||
call.async_call(
|
||||
"number",
|
||||
"set_value",
|
||||
{
|
||||
"entity_id": "number.mock_valve",
|
||||
"value": 10,
|
||||
}, # the min allowed value
|
||||
),
|
||||
call.async_call(
|
||||
"number",
|
||||
"set_value",
|
||||
{
|
||||
"entity_id": "number.mock_valve",
|
||||
"value": 50,
|
||||
}, # the max allowed value
|
||||
),
|
||||
]
|
||||
)
|
||||
# switch to Eco
|
||||
await entity.async_set_preset_mode(PRESET_ECO)
|
||||
assert entity.preset_mode is PRESET_ECO
|
||||
|
||||
Reference in New Issue