Issue #280 - enable to use central config for window configuration

This commit is contained in:
Jean-Marc Collin
2023-12-18 21:39:58 +00:00
parent 30c3418f1b
commit 04d0b28f1d
5 changed files with 36 additions and 7 deletions

View File

@@ -171,7 +171,7 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
_LOGGER.error(
"Only one window detection method should be used. Use window_sensor or auto window open detection but not both"
)
raise WindowOpenDetectionMethod(CONF_WINDOW_SENSOR)
raise WindowOpenDetectionMethod(CONF_WINDOW_AUTO_OPEN_THRESHOLD)
# Check that is USE_CENTRAL config is used, that a central config exists
if self._central_config is None:
@@ -408,7 +408,11 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
next_step = self.async_step_motion
# If comes from async_step_spec_window
elif self._infos.get(COMES_FROM) == "async_step_spec_window":
schema = STEP_CENTRAL_WINDOW_DATA_SCHEMA
# If we have a window sensor don't display the auto window parameters
if self._infos.get(CONF_WINDOW_SENSOR) is not None:
schema = STEP_CENTRAL_WINDOW_WO_AUTO_DATA_SCHEMA
else:
schema = STEP_CENTRAL_WINDOW_DATA_SCHEMA
elif user_input and user_input.get(CONF_USE_WINDOW_CENTRAL_CONFIG) is False:
next_step = self.async_step_spec_window
@@ -423,6 +427,8 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
)
schema = STEP_CENTRAL_WINDOW_DATA_SCHEMA
if self._infos.get(CONF_WINDOW_SENSOR) is not None:
schema = STEP_CENTRAL_WINDOW_WO_AUTO_DATA_SCHEMA
self._infos[COMES_FROM] = "async_step_spec_window"

View File

@@ -195,6 +195,12 @@ STEP_CENTRAL_WINDOW_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
}
)
STEP_CENTRAL_WINDOW_WO_AUTO_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
{
vol.Optional(CONF_WINDOW_DELAY, default=30): cv.positive_int,
}
)
STEP_MOTION_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
{
vol.Optional(CONF_MOTION_SENSOR): selector.EntitySelector(

View File

@@ -139,6 +139,11 @@ MOCK_PRESETS_AC_CONFIG = {
MOCK_WINDOW_CONFIG = {
CONF_WINDOW_SENSOR: "binary_sensor.window_sensor",
# Not used normally only for tests to avoid rewrite all tests
CONF_WINDOW_DELAY: 10,
}
MOCK_WINDOW_DELAY_CONFIG = {
CONF_WINDOW_DELAY: 10,
}

View File

@@ -31,6 +31,8 @@ from .commons import * # pylint: disable=wildcard-import, unused-wildcard-impor
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_add_a_central_config(hass: HomeAssistant, skip_hass_states_is_state):
"""Tests the clean_central_config_doubon of base_thermostat"""
central_config_entry = MockConfigEntry(
@@ -95,6 +97,8 @@ async def test_add_a_central_config(hass: HomeAssistant, skip_hass_states_is_sta
assert central_configuration is not None
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_minimal_over_switch_wo_central_config(
hass: HomeAssistant, skip_hass_states_is_state, init_vtherm_api
):
@@ -169,6 +173,8 @@ async def test_minimal_over_switch_wo_central_config(
assert entity.is_inversed
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_full_over_switch_wo_central_config(
hass: HomeAssistant, skip_hass_states_is_state, init_vtherm_api
):
@@ -281,6 +287,8 @@ async def test_full_over_switch_wo_central_config(
assert entity._presence_sensor_entity_id == "binary_sensor.mock_presence_sensor"
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_full_over_switch_with_central_config(
hass: HomeAssistant, skip_hass_states_is_state, init_central_config
):
@@ -388,6 +396,8 @@ async def test_full_over_switch_with_central_config(
assert entity._presence_sensor_entity_id == "binary_sensor.mock_presence_sensor"
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_over_switch_with_central_config_but_no_central_config(
hass: HomeAssistant, skip_hass_states_get, init_vtherm_api
):

View File

@@ -472,15 +472,17 @@ async def test_user_config_flow_window_auto_ko(
result = await hass.config_entries.flow.async_configure(
result["flow_id"],
user_input=MOCK_WINDOW_AUTO_CONFIG,
user_input=MOCK_WINDOW_DELAY_CONFIG,
)
# Since issue #280 we cannot have the error because we only display the
# MOCK_WINDOW_DELAY_CONFIG form if we have a sensor configured
assert result["type"] == data_entry_flow.RESULT_TYPE_FORM
# We should stay on window with an error
assert result["errors"] == {
"window_sensor_entity_id": "window_open_detection_method"
}
assert result["step_id"] == "window"
assert result["errors"] == {}
# "window_sensor_entity_id": "window_open_detection_method"
# }
assert result["step_id"] == "advanced"
@pytest.mark.parametrize("expected_lingering_tasks", [True])