Add AC mode configFlow

This commit is contained in:
Jean-Marc Collin
2023-07-22 10:47:10 +02:00
parent 61eae8c066
commit 9709a9eed0
6 changed files with 191 additions and 71 deletions

View File

@@ -61,7 +61,9 @@ from .const import (
CONF_CYCLE_MIN,
CONF_PRESET_POWER,
CONF_PRESETS,
CONF_PRESETS_WITH_AC,
CONF_PRESETS_AWAY,
CONF_PRESETS_AWAY_WITH_AC,
CONF_PRESETS_SELECTIONABLE,
CONF_PROP_FUNCTION,
CONF_TPI_COEF_EXT,
@@ -83,6 +85,7 @@ from .const import (
CONF_USE_MOTION_FEATURE,
CONF_USE_PRESENCE_FEATURE,
CONF_USE_POWER_FEATURE,
CONF_USE_AC_MODE,
CONF_THERMOSTAT_TYPES,
UnknownEntity,
WindowOpenDetectionMethod,
@@ -132,35 +135,6 @@ def add_suggested_values_to_schema(
return vol.Schema(schema)
# def is_temperature_sensor(sensor: RegistryEntry):
# """Check if a registryEntry is a temperature sensor or assimilable to a temperature sensor"""
# if not sensor.entity_id.startswith(
# INPUT_NUMBER_DOMAIN
# ) and not sensor.entity_id.startswith(SENSOR_DOMAIN):
# return False
# return (
# sensor.device_class == TEMPERATURE
# or sensor.original_device_class == TEMPERATURE
# or sensor.unit_of_measurement in TEMPERATURE_UNITS
# )
#
#
# def is_power_sensor(sensor: RegistryEntry):
# """Check if a registryEntry is a power sensor or assimilable to a temperature sensor"""
# if not sensor.entity_id.startswith(
# INPUT_NUMBER_DOMAIN
# ) and not sensor.entity_id.startswith(SENSOR_DOMAIN):
# return False
# return (
# sensor.unit_of_measurement
# in [
# UnitOfPower.KILO_WATT,
# UnitOfPower.WATT,
# UnitOfPower.BTU_PER_HOUR,
# ]
# )
class VersatileThermostatBaseConfigFlow(FlowHandler):
"""The base Config flow class. Used to put some code in commons."""
@@ -257,6 +231,7 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
vol.Required(CONF_CLIMATE): selector.EntitySelector(
selector.EntitySelectorConfig(domain=CLIMATE_DOMAIN),
),
vol.Optional(CONF_USE_AC_MODE, default=False): cv.boolean,
}
)
@@ -274,6 +249,15 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
}
)
self.STEP_PRESETS_WITH_AC_DATA_SCHEMA = ( # pylint: disable=invalid-name
vol.Schema( # pylint: disable=invalid-name
{
vol.Optional(v, default=0.0): vol.Coerce(float)
for (k, v) in CONF_PRESETS_WITH_AC.items()
}
)
)
self.STEP_WINDOW_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
{
vol.Optional(CONF_WINDOW_SENSOR): selector.EntitySelector(
@@ -340,6 +324,27 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
}
)
self.STEP_PRESENCE_WITH_AC_DATA_SCHEMA = ( # pylint: disable=invalid-name
vol.Schema(
{
vol.Optional(CONF_PRESENCE_SENSOR): selector.EntitySelector(
selector.EntitySelectorConfig(
domain=[
PERSON_DOMAIN,
BINARY_SENSOR_DOMAIN,
INPUT_BOOLEAN_DOMAIN,
]
),
),
}
).extend(
{
vol.Optional(v, default=17): vol.Coerce(float)
for (k, v) in CONF_PRESETS_AWAY_WITH_AC.items()
}
)
)
self.STEP_ADVANCED_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
{
vol.Required(
@@ -489,9 +494,12 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
elif self._infos[CONF_USE_PRESENCE_FEATURE]:
next_step = self.async_step_presence
return await self.generic_step(
"presets", self.STEP_PRESETS_DATA_SCHEMA, user_input, next_step
)
if self._infos[CONF_USE_AC_MODE]:
schema = self.STEP_PRESETS_WITH_AC_DATA_SCHEMA
else:
schema = self.STEP_PRESETS_DATA_SCHEMA
return await self.generic_step("presets", schema, user_input, next_step)
async def async_step_window(self, user_input: dict | None = None) -> FlowResult:
"""Handle the window sensor flow steps"""
@@ -542,9 +550,14 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
"""Handle the presence management flow steps"""
_LOGGER.debug("Into ConfigFlow.async_step_presence user_input=%s", user_input)
if self._infos[CONF_USE_AC_MODE]:
schema = self.STEP_PRESENCE_WITH_AC_DATA_SCHEMA
else:
schema = self.STEP_PRESENCE_DATA_SCHEMA
return await self.generic_step(
"presence",
self.STEP_PRESENCE_DATA_SCHEMA,
schema,
user_input,
self.async_step_advanced,
)
@@ -676,9 +689,12 @@ class VersatileThermostatOptionsFlowHandler(
elif self._infos[CONF_USE_PRESENCE_FEATURE]:
next_step = self.async_step_presence
return await self.generic_step(
"presets", self.STEP_PRESETS_DATA_SCHEMA, user_input, next_step
)
if self._infos[CONF_USE_AC_MODE]:
schema = self.STEP_PRESETS_WITH_AC_DATA_SCHEMA
else:
schema = self.STEP_PRESETS_DATA_SCHEMA
return await self.generic_step("presets", schema, user_input, next_step)
async def async_step_window(self, user_input: dict | None = None) -> FlowResult:
"""Handle the window sensor flow steps"""
@@ -736,9 +752,14 @@ class VersatileThermostatOptionsFlowHandler(
"Into OptionsFlowHandler.async_step_presence user_input=%s", user_input
)
if self._infos[CONF_USE_AC_MODE]:
schema = self.STEP_PRESENCE_WITH_AC_DATA_SCHEMA
else:
schema = self.STEP_PRESENCE_DATA_SCHEMA
return await self.generic_step(
"presence",
self.STEP_PRESENCE_DATA_SCHEMA,
schema,
user_input,
self.async_step_advanced,
)

View File

@@ -11,6 +11,10 @@ from homeassistant.components.climate import (
ClimateEntityFeature,
)
PRESET_ECO_AC = PRESET_ECO + "_ac"
PRESET_COMFORT_AC = PRESET_COMFORT + "_ac"
PRESET_BOOST_AC = PRESET_BOOST + "_ac"
from homeassistant.exceptions import HomeAssistantError
from .prop_algorithm import (
@@ -64,6 +68,7 @@ CONF_USE_WINDOW_FEATURE = "use_window_feature"
CONF_USE_MOTION_FEATURE = "use_motion_feature"
CONF_USE_PRESENCE_FEATURE = "use_presence_feature"
CONF_USE_POWER_FEATURE = "use_power_feature"
CONF_USE_AC_MODE = "use_ac_mode"
CONF_WINDOW_AUTO_OPEN_THRESHOLD = "window_auto_open_threshold"
CONF_WINDOW_AUTO_CLOSE_THRESHOLD = "window_auto_close_threshold"
CONF_WINDOW_AUTO_MAX_DURATION = "window_auto_max_duration"
@@ -77,14 +82,39 @@ CONF_PRESETS = {
)
}
CONF_PRESETS_WITH_AC = {
p: f"{p}_temp"
for p in (
PRESET_ECO,
PRESET_COMFORT,
PRESET_BOOST,
PRESET_ECO_AC,
PRESET_COMFORT_AC,
PRESET_BOOST_AC,
)
}
PRESET_AWAY_SUFFIX = "_away"
CONF_PRESETS_AWAY = {
p: f"{p}_temp"
for p in (
PRESET_ECO + PRESET_AWAY_SUFFIX,
PRESET_BOOST + PRESET_AWAY_SUFFIX,
PRESET_COMFORT + PRESET_AWAY_SUFFIX,
PRESET_BOOST + PRESET_AWAY_SUFFIX,
)
}
CONF_PRESETS_AWAY_WITH_AC = {
p: f"{p}_temp"
for p in (
PRESET_ECO + PRESET_AWAY_SUFFIX,
PRESET_COMFORT + PRESET_AWAY_SUFFIX,
PRESET_BOOST + PRESET_AWAY_SUFFIX,
PRESET_ECO_AC + PRESET_AWAY_SUFFIX,
PRESET_COMFORT_AC + PRESET_AWAY_SUFFIX,
PRESET_BOOST_AC + PRESET_AWAY_SUFFIX,
)
}
@@ -92,6 +122,8 @@ CONF_PRESETS_SELECTIONABLE = [PRESET_ECO, PRESET_COMFORT, PRESET_BOOST]
CONF_PRESETS_VALUES = list(CONF_PRESETS.values())
CONF_PRESETS_AWAY_VALUES = list(CONF_PRESETS_AWAY.values())
CONF_PRESETS_WITH_AC_VALUES = list(CONF_PRESETS_WITH_AC.values())
CONF_PRESETS_AWAY_WITH_AC_VALUES = list(CONF_PRESETS_AWAY_WITH_AC.values())
ALL_CONF = (
[
@@ -130,9 +162,12 @@ ALL_CONF = (
CONF_USE_MOTION_FEATURE,
CONF_USE_PRESENCE_FEATURE,
CONF_USE_POWER_FEATURE,
CONF_USE_AC_MODE,
]
+ CONF_PRESETS_VALUES
+ CONF_PRESETS_AWAY_VALUES,
+ CONF_PRESETS_AWAY_VALUES
+ CONF_PRESETS_WITH_AC_VALUES
+ CONF_PRESETS_AWAY_WITH_AC_VALUES,
)
CONF_FUNCTIONS = [

View File

@@ -30,7 +30,8 @@
"heater_entity3_id": "3rd Heater switch",
"heater_entity4_id": "4th Heater switch",
"proportional_function": "Algorithm",
"climate_entity_id": "Underlying thermostat"
"climate_entity_id": "Underlying thermostat",
"ac_mode": "AC mode"
},
"data_description": {
"heater_entity_id": "Mandatory heater entity id",
@@ -38,7 +39,8 @@
"heater_entity3_id": "Optional 3rd Heater entity id. Leave empty if not used",
"heater_entity4_id": "Optional 4th Heater entity id. Leave empty if not used",
"proportional_function": "Algorithm to use (TPI is the only one for now)",
"climate_entity_id": "Underlying climate entity id"
"climate_entity_id": "Underlying climate entity id",
"ac_mode": "Use the Air Conditioning (AC) mode"
}
},
"tpi": {
@@ -55,7 +57,10 @@
"data": {
"eco_temp": "Temperature in Eco preset",
"comfort_temp": "Temperature in Comfort preset",
"boost_temp": "Temperature in Boost preset"
"boost_temp": "Temperature in Boost preset",
"eco_ac_temp": "Temperature in Eco preset for AC mode",
"comfort_ac_temp": "Temperature in Comfort preset for AC mode",
"boost_ac_temp": "Temperature in Boost preset for AC mode"
}
},
"window": {
@@ -102,7 +107,10 @@
"presence_sensor_entity_id": "Presence sensor entity id (true is present)",
"eco_away_temp": "Temperature in Eco preset when no presence",
"comfort_away_temp": "Temperature in Comfort preset when no presence",
"boost_away_temp": "Temperature in Boost preset when no presence"
"boost_away_temp": "Temperature in Boost preset when no presence",
"eco_ac_away_temp": "Temperature in Eco preset when no presence in AC mode",
"comfort_ac_away_temp": "Temperature in Comfort preset when no presence in AC mode",
"boost_ac_away_temp": "Temperature in Boost preset when no presence in AC mode"
}
},
"advanced": {
@@ -161,7 +169,8 @@
"heater_entity3_id": "3rd Heater switch",
"heater_entity4_id": "4th Heater switch",
"proportional_function": "Algorithm",
"climate_entity_id": "Underlying thermostat"
"climate_entity_id": "Underlying thermostat",
"ac_mode": "AC mode"
},
"data_description": {
"heater_entity_id": "Mandatory heater entity id",
@@ -169,7 +178,8 @@
"heater_entity3_id": "Optional 3rd Heater entity id. Leave empty if not used",
"heater_entity4_id": "Optional 4th Heater entity id. Leave empty if not used",
"proportional_function": "Algorithm to use (TPI is the only one for now)",
"climate_entity_id": "Underlying climate entity id"
"climate_entity_id": "Underlying climate entity id",
"ac_mode": "Use the Air Conditioning (AC) mode"
}
},
"tpi": {
@@ -186,7 +196,10 @@
"data": {
"eco_temp": "Temperature in Eco preset",
"comfort_temp": "Temperature in Comfort preset",
"boost_temp": "Temperature in Boost preset"
"boost_temp": "Temperature in Boost preset",
"eco_ac_temp": "Temperature in Eco preset for AC mode",
"comfort_ac_temp": "Temperature in Comfort preset for AC mode",
"boost_ac_temp": "Temperature in Boost preset for AC mode"
}
},
"window": {
@@ -233,7 +246,10 @@
"presence_sensor_entity_id": "Presence sensor entity id (true is present)",
"eco_away_temp": "Temperature in Eco preset when no presence",
"comfort_away_temp": "Temperature in Comfort preset when no presence",
"boost_away_temp": "Temperature in Boost preset when no presence"
"boost_away_temp": "Temperature in Boost preset when no presence",
"eco_ac_away_temp": "Temperature in Eco preset when no presence in AC mode",
"comfort_ac_away_temp": "Temperature in Comfort preset when no presence in AC mode",
"boost_ac_away_temp": "Temperature in Boost preset when no presence in AC mode"
}
},
"advanced": {

View File

@@ -30,7 +30,8 @@
"heater_entity3_id": "3rd Heater switch",
"heater_entity4_id": "4th Heater switch",
"proportional_function": "Algorithm",
"climate_entity_id": "Underlying thermostat"
"climate_entity_id": "Underlying thermostat",
"ac_mode": "AC mode"
},
"data_description": {
"heater_entity_id": "Mandatory heater entity id",
@@ -38,7 +39,8 @@
"heater_entity3_id": "Optional 3rd Heater entity id. Leave empty if not used",
"heater_entity4_id": "Optional 4th Heater entity id. Leave empty if not used",
"proportional_function": "Algorithm to use (TPI is the only one for now)",
"climate_entity_id": "Underlying climate entity id"
"climate_entity_id": "Underlying climate entity id",
"ac_mode": "Use the Air Conditioning (AC) mode"
}
},
"tpi": {
@@ -55,7 +57,10 @@
"data": {
"eco_temp": "Temperature in Eco preset",
"comfort_temp": "Temperature in Comfort preset",
"boost_temp": "Temperature in Boost preset"
"boost_temp": "Temperature in Boost preset",
"eco_ac_temp": "Temperature in Eco preset for AC mode",
"comfort_ac_temp": "Temperature in Comfort preset for AC mode",
"boost_ac_temp": "Temperature in Boost preset for AC mode"
}
},
"window": {
@@ -102,7 +107,10 @@
"presence_sensor_entity_id": "Presence sensor entity id (true is present)",
"eco_away_temp": "Temperature in Eco preset when no presence",
"comfort_away_temp": "Temperature in Comfort preset when no presence",
"boost_away_temp": "Temperature in Boost preset when no presence"
"boost_away_temp": "Temperature in Boost preset when no presence",
"eco_ac_away_temp": "Temperature in Eco preset when no presence in AC mode",
"comfort_ac_away_temp": "Temperature in Comfort preset when no presence in AC mode",
"boost_ac_away_temp": "Temperature in Boost preset when no presence in AC mode"
}
},
"advanced": {
@@ -161,7 +169,8 @@
"heater_entity3_id": "3rd Heater switch",
"heater_entity4_id": "4th Heater switch",
"proportional_function": "Algorithm",
"climate_entity_id": "Underlying thermostat"
"climate_entity_id": "Underlying thermostat",
"ac_mode": "AC mode"
},
"data_description": {
"heater_entity_id": "Mandatory heater entity id",
@@ -169,7 +178,8 @@
"heater_entity3_id": "Optional 3rd Heater entity id. Leave empty if not used",
"heater_entity4_id": "Optional 4th Heater entity id. Leave empty if not used",
"proportional_function": "Algorithm to use (TPI is the only one for now)",
"climate_entity_id": "Underlying climate entity id"
"climate_entity_id": "Underlying climate entity id",
"ac_mode": "Use the Air Conditioning (AC) mode"
}
},
"tpi": {
@@ -186,7 +196,10 @@
"data": {
"eco_temp": "Temperature in Eco preset",
"comfort_temp": "Temperature in Comfort preset",
"boost_temp": "Temperature in Boost preset"
"boost_temp": "Temperature in Boost preset",
"eco_ac_temp": "Temperature in Eco preset for AC mode",
"comfort_ac_temp": "Temperature in Comfort preset for AC mode",
"boost_ac_temp": "Temperature in Boost preset for AC mode"
}
},
"window": {
@@ -233,7 +246,10 @@
"presence_sensor_entity_id": "Presence sensor entity id (true is present)",
"eco_away_temp": "Temperature in Eco preset when no presence",
"comfort_away_temp": "Temperature in Comfort preset when no presence",
"boost_away_temp": "Temperature in Boost preset when no presence"
"boost_away_temp": "Temperature in Boost preset when no presence",
"eco_ac_away_temp": "Temperature in Eco preset when no presence in AC mode",
"comfort_ac_away_temp": "Temperature in Comfort preset when no presence in AC mode",
"boost_ac_away_temp": "Temperature in Boost preset when no presence in AC mode"
}
},
"advanced": {

View File

@@ -29,7 +29,8 @@
"heater_entity3_id": "3ème radiateur",
"heater_entity4_id": "4ème radiateur",
"proportional_function": "Algorithme",
"climate_entity_id": "Thermostat sous-jacent"
"climate_entity_id": "Thermostat sous-jacent",
"ac_mode": "AC mode ?"
},
"data_description": {
"heater_entity_id": "Entity id du 1er radiateur obligatoire",
@@ -37,7 +38,8 @@
"heater_entity3_id": "Optionnel entity id du 3ème radiateur",
"heater_entity4_id": "Optionnel entity id du 4ème radiateur",
"proportional_function": "Algorithme à utiliser (Seul TPI est disponible pour l'instant)",
"climate_entity_id": "Entity id du thermostat sous-jacent"
"climate_entity_id": "Entity id du thermostat sous-jacent",
"ac_mode": "Utilisation du mode Air Conditionné (AC)"
}
},
"tpi": {
@@ -54,7 +56,10 @@
"data": {
"eco_temp": "Température en preset Eco",
"comfort_temp": "Température en preset Comfort",
"boost_temp": "Température en preset Boost"
"boost_temp": "Température en preset Boost",
"eco_ac_temp": "Température en preset Eco en mode AC",
"comfort_ac_temp": "Température en preset Comfort en mode AC",
"boost_ac_temp": "Température en preset Boost en mode AC"
}
},
"window": {
@@ -101,7 +106,10 @@
"presence_sensor_entity_id": "Capteur de présence entity id (true si quelqu'un est présent)",
"eco_away_temp": "Température en preset Eco en cas d'absence",
"comfort_away_temp": "Température en preset Comfort en cas d'absence",
"boost_away_temp": "Température en preset Boost en cas d'absence"
"boost_away_temp": "Température en preset Boost en cas d'absence",
"eco_ac_away_temp": "Température en preset Eco en cas d'absence en mode AC",
"comfort_ac_away_temp": "Température en preset Comfort en cas d'absence en mode AC",
"boost_ac_away_temp": "Température en preset Boost en cas d'absence en mode AC"
}
},
"advanced": {
@@ -161,7 +169,8 @@
"heater_entity3_id": "3ème radiateur",
"heater_entity4_id": "4ème radiateur",
"proportional_function": "Algorithme",
"climate_entity_id": "Thermostat sous-jacent"
"climate_entity_id": "Thermostat sous-jacent",
"ac_mode": "AC mode ?"
},
"data_description": {
"heater_entity_id": "Entity id du 1er radiateur obligatoire",
@@ -169,7 +178,8 @@
"heater_entity3_id": "Optionnel entity id du 3ème radiateur",
"heater_entity4_id": "Optionnel entity id du 4ème radiateur",
"proportional_function": "Algorithme à utiliser (Seul TPI est disponible pour l'instant)",
"climate_entity_id": "Entity id du thermostat sous-jacent"
"climate_entity_id": "Entity id du thermostat sous-jacent",
"ac_mode": "Utilisation du mode Air Conditionné (AC)"
}
},
"tpi": {
@@ -186,7 +196,10 @@
"data": {
"eco_temp": "Température en preset Eco",
"comfort_temp": "Température en preset Comfort",
"boost_temp": "Température en preset Boost"
"boost_temp": "Température en preset Boost",
"eco_ac_temp": "Température en preset Eco en mode AC",
"comfort_ac_temp": "Température en preset Comfort en mode AC",
"boost_ac_temp": "Température en preset Boost en mode AC"
}
},
"window": {
@@ -233,7 +246,10 @@
"presence_sensor_entity_id": "Capteur de présence entity id (true si quelqu'un est présent)",
"eco_away_temp": "Température en preset Eco en cas d'absence",
"comfort_away_temp": "Température en preset Comfort en cas d'absence",
"boost_away_temp": "Température en preset Boost en cas d'absence"
"boost_away_temp": "Température en preset Boost en cas d'absence",
"eco_ac_away_temp": "Température en preset Eco en cas d'absence en mode AC",
"comfort_ac_away_temp": "Température en preset Comfort en cas d'absence en mode AC",
"boost_ac_away_temp": "Température en preset Boost en cas d'absence en mode AC"
}
},
"advanced": {

View File

@@ -30,7 +30,8 @@
"heater_entity3_id": "Terzo riscaldatore",
"heater_entity4_id": "Quarto riscaldatore",
"proportional_function": "Algoritmo",
"climate_entity_id": "Termostato sottostante"
"climate_entity_id": "Termostato sottostante",
"ac_mode": "AC mode ?"
},
"data_description": {
"heater_entity_id": "Entity id obbligatoria del primo riscaldatore",
@@ -38,7 +39,8 @@
"heater_entity3_id": "Entity id del terzo riscaldatore facoltativo. Lasciare vuoto se non utilizzato",
"heater_entity4_id": "Entity id del quarto riscaldatore facoltativo. Lasciare vuoto se non utilizzato",
"proportional_function": "Algoritmo da utilizzare (il TPI per adesso è l'unico)",
"climate_entity_id": "Entity id del termostato sottostante"
"climate_entity_id": "Entity id del termostato sottostante",
"ac_mode": "Utilizzare la modalità AC (Air Conditioned) ?"
}
},
"tpi": {
@@ -55,7 +57,10 @@
"data": {
"eco_temp": "Temperatura nel preset Eco",
"comfort_temp": "Temperatura nel preset Comfort",
"boost_temp": "Temperatura nel preset Boost"
"boost_temp": "Temperatura nel preset Boost",
"eco_ac_temp": "Temperatura nel preset Eco (AC mode)",
"comfort_ac_temp": "Temperatura nel preset Comfort (AC mode)",
"boost_ac_temp": "Temperatura nel preset Boost (AC mode)"
}
},
"window": {
@@ -102,7 +107,10 @@
"presence_sensor_entity_id": "Entity id sensore presenza (true se è presente qualcuno)",
"eco_away_temp": "Temperatura al preset Eco in caso d'assenza",
"comfort_away_temp": "Temperatura al preset Comfort in caso d'assenza",
"boost_away_temp": "Temperatura al preset Boost in caso d'assenza"
"boost_away_temp": "Temperatura al preset Boost in caso d'assenza",
"eco_ac_away_temp": "Temperatura al preset Eco in caso d'assenza (AC mode)",
"comfort_ac_away_temp": "Temperatura al preset Comfort in caso d'assenza (AC mode)",
"boost_ac_away_temp": "Temperatura al preset Boost in caso d'assenza (AC mode)"
}
},
"advanced": {
@@ -161,7 +169,8 @@
"heater_entity3_id": "Terzo interruttore riscaldatore",
"heater_entity4_id": "Quarto interruttore riscaldatore",
"proportional_function": "Algoritmo",
"climate_entity_id": "Termostato sottostante"
"climate_entity_id": "Termostato sottostante",
"ac_mode": "AC mode ?"
},
"data_description": {
"heater_entity_id": "Entity id obbligatoria del primo riscaldatore",
@@ -169,7 +178,8 @@
"heater_entity3_id": "Entity id del terzo riscaldatore facoltativo. Lasciare vuoto se non utilizzato",
"heater_entity4_id": "Entity id del quarto riscaldatore facoltativo. Lasciare vuoto se non utilizzato",
"proportional_function": "Algoritmo da utilizzare (il TPI per adesso è l'unico)",
"climate_entity_id": "Entity id del termostato sottostante"
"climate_entity_id": "Entity id del termostato sottostante",
"ac_mode": "Utilizzare la modalità AC (Air Conditioned) ?"
}
},
"tpi": {
@@ -186,7 +196,10 @@
"data": {
"eco_temp": "Temperatura nel preset Eco",
"comfort_temp": "Temperatura nel preset Comfort",
"boost_temp": "Temperatura nel preset Boost"
"boost_temp": "Temperatura nel preset Boost",
"eco_ac_temp": "Temperatura nel preset Eco (AC mode)",
"comfort_ac_temp": "Temperatura nel preset Comfort (AC mode)",
"boost_ac_temp": "Temperatura nel preset Boost (AC mode)"
}
},
"window": {
@@ -233,7 +246,10 @@
"presence_sensor_entity_id": "Entity id sensore presenza (true se è presente qualcuno)",
"eco_away_temp": "Temperatura al preset Eco in caso d'assenza",
"comfort_away_temp": "Temperatura al preset Comfort in caso d'assenza",
"boost_away_temp": "Temperatura al preset Boost in caso d'assenza"
"boost_away_temp": "Temperatura al preset Boost in caso d'assenza",
"eco_ac_away_temp": "Temperatura al preset Eco in caso d'assenza (AC mode)",
"comfort_ac_away_temp": "Temperatura al preset Comfort in caso d'assenza (AC mode)",
"boost_ac_away_temp": "Temperatura al preset Boost in caso d'assenza (AC mode)"
}
},
"advanced": {