Issue #820 - improve power shedding algorithm

This commit is contained in:
Jean-Marc Collin
2025-01-13 17:25:19 +00:00
parent 05e31358a4
commit 9628e9a93b

View File

@@ -195,6 +195,16 @@ class UnderlyingEntity:
self._cancel_cycle()
await self.turn_off()
async def check_overpowering(self) -> bool:
"""Check that a underlying can be turned on, else
activate the overpowering state of the VTherm associated.
Returns True if the check is ok (no overpowering needed)"""
if not await self._thermostat.power_manager.check_power_available():
_LOGGER.debug("%s - overpowering is detected", self)
await self._thermostat.power_manager.set_overpowering(True)
return False
return True
class UnderlyingSwitch(UnderlyingEntity):
"""Represent a underlying switch"""
@@ -318,6 +328,10 @@ class UnderlyingSwitch(UnderlyingEntity):
"""Turn heater toggleable device on."""
self._keep_alive.cancel() # Cancel early to avoid a turn_on/turn_off race condition
_LOGGER.debug("%s - Starting underlying entity %s", self, self._entity_id)
if not await self.check_overpowering():
return
command = SERVICE_TURN_ON if not self.is_inversed else SERVICE_TURN_OFF
domain = self._entity_id.split(".")[0]
try:
@@ -414,10 +428,6 @@ class UnderlyingSwitch(UnderlyingEntity):
await self.turn_off()
return
# if await self._thermostat.power_manager.check_overpowering():
# _LOGGER.debug("%s - End of cycle (3)", self)
# return
# safety mode could have change the on_time percent
await self._thermostat.safety_manager.refresh_state()
time = self._on_time_sec
@@ -557,6 +567,10 @@ class UnderlyingClimate(UnderlyingEntity):
)
return False
# When turning on a climate, check that power is available
if hvac_mode in (HVACMode.HEAT, HVACMode.COOL) and not await self.check_overpowering():
return False
data = {ATTR_ENTITY_ID: self._entity_id, "hvac_mode": hvac_mode}
await self._hass.services.async_call(
CLIMATE_DOMAIN,