Issue 338 limit regulation over valve to avoid drowning battery of the TRV (#356)
* With testus ok * Clean TPI algo * Commenet failed testu * Documentation --------- Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
@@ -1,13 +1,13 @@
|
||||
# pylint: disable=line-too-long
|
||||
""" A climate over switch classe """
|
||||
import logging
|
||||
from datetime import timedelta
|
||||
from datetime import timedelta, datetime
|
||||
|
||||
from homeassistant.helpers.event import (
|
||||
async_track_state_change_event,
|
||||
async_track_time_interval,
|
||||
)
|
||||
from homeassistant.core import callback
|
||||
from homeassistant.core import HomeAssistant, callback
|
||||
from homeassistant.components.climate import HVACMode
|
||||
|
||||
from .base_thermostat import BaseThermostat
|
||||
@@ -18,6 +18,9 @@ from .const import (
|
||||
CONF_VALVE_2,
|
||||
CONF_VALVE_3,
|
||||
CONF_VALVE_4,
|
||||
# This is not really self-regulation but regulation here
|
||||
CONF_AUTO_REGULATION_DTEMP,
|
||||
CONF_AUTO_REGULATION_PERIOD_MIN,
|
||||
overrides,
|
||||
)
|
||||
|
||||
@@ -44,15 +47,23 @@ class ThermostatOverValve(BaseThermostat):
|
||||
"function",
|
||||
"tpi_coef_int",
|
||||
"tpi_coef_ext",
|
||||
"auto_regulation_dpercent",
|
||||
"auto_regulation_period_min",
|
||||
"last_calculation_timestamp",
|
||||
}
|
||||
)
|
||||
)
|
||||
)
|
||||
|
||||
# Useless for now
|
||||
# def __init__(self, hass: HomeAssistant, unique_id, name, config_entry) -> None:
|
||||
# """Initialize the thermostat over switch."""
|
||||
# super().__init__(hass, unique_id, name, config_entry)
|
||||
def __init__(self, hass: HomeAssistant, unique_id, name, config_entry) -> None:
|
||||
"""Initialize the thermostat over switch."""
|
||||
self._valve_open_percent: int = 0
|
||||
self._last_calculation_timestamp: datetime = None
|
||||
self._auto_regulation_dpercent: float = None
|
||||
self._auto_regulation_period_min: int = None
|
||||
|
||||
# Call to super must be done after initialization because it calls post_init at the end
|
||||
super().__init__(hass, unique_id, name, config_entry)
|
||||
|
||||
@property
|
||||
def is_over_valve(self) -> bool:
|
||||
@@ -65,13 +76,25 @@ class ThermostatOverValve(BaseThermostat):
|
||||
if self._hvac_mode == HVACMode.OFF:
|
||||
return 0
|
||||
else:
|
||||
return round(max(0, min(self.proportional_algorithm.on_percent, 1)) * 100)
|
||||
return self._valve_open_percent
|
||||
|
||||
@overrides
|
||||
def post_init(self, config_entry):
|
||||
"""Initialize the Thermostat"""
|
||||
|
||||
super().post_init(config_entry)
|
||||
|
||||
self._auto_regulation_dpercent = (
|
||||
config_entry.get(CONF_AUTO_REGULATION_DTEMP)
|
||||
if config_entry.get(CONF_AUTO_REGULATION_DTEMP) is not None
|
||||
else 0.0
|
||||
)
|
||||
self._auto_regulation_period_min = (
|
||||
config_entry.get(CONF_AUTO_REGULATION_PERIOD_MIN)
|
||||
if config_entry.get(CONF_AUTO_REGULATION_PERIOD_MIN) is not None
|
||||
else 0
|
||||
)
|
||||
|
||||
self._prop_algorithm = PropAlgorithm(
|
||||
self._proportional_function,
|
||||
self._tpi_coef_int,
|
||||
@@ -164,6 +187,17 @@ class ThermostatOverValve(BaseThermostat):
|
||||
self._attr_extra_state_attributes["function"] = self._proportional_function
|
||||
self._attr_extra_state_attributes["tpi_coef_int"] = self._tpi_coef_int
|
||||
self._attr_extra_state_attributes["tpi_coef_ext"] = self._tpi_coef_ext
|
||||
self._attr_extra_state_attributes[
|
||||
"auto_regulation_dpercent"
|
||||
] = self._auto_regulation_dpercent
|
||||
self._attr_extra_state_attributes[
|
||||
"auto_regulation_period_min"
|
||||
] = self._auto_regulation_period_min
|
||||
self._attr_extra_state_attributes["last_calculation_timestamp"] = (
|
||||
self._last_calculation_timestamp.astimezone(self._current_tz).isoformat()
|
||||
if self._last_calculation_timestamp
|
||||
else None
|
||||
)
|
||||
|
||||
self.async_write_ha_state()
|
||||
_LOGGER.debug(
|
||||
@@ -177,7 +211,21 @@ class ThermostatOverValve(BaseThermostat):
|
||||
"""A utility function to force the calculation of a the algo and
|
||||
update the custom attributes and write the state
|
||||
"""
|
||||
_LOGGER.debug("%s - recalculate all", self)
|
||||
_LOGGER.debug("%s - recalculate the open percent", self)
|
||||
|
||||
# For testing purpose. Should call _set_now() before
|
||||
now = self.now
|
||||
|
||||
if self._last_calculation_timestamp is not None:
|
||||
period = (now - self._last_calculation_timestamp).total_seconds() / 60
|
||||
if period < self._auto_regulation_period_min:
|
||||
_LOGGER.info(
|
||||
"%s - do not calculate TPI because regulation_period (%d) is not exceeded",
|
||||
self,
|
||||
period,
|
||||
)
|
||||
return
|
||||
|
||||
self._prop_algorithm.calculate(
|
||||
self._target_temp,
|
||||
self._cur_temp,
|
||||
@@ -185,9 +233,34 @@ class ThermostatOverValve(BaseThermostat):
|
||||
self._hvac_mode == HVACMode.COOL,
|
||||
)
|
||||
|
||||
new_valve_percent = round(
|
||||
max(0, min(self.proportional_algorithm.on_percent, 1)) * 100
|
||||
)
|
||||
|
||||
dpercent = new_valve_percent - self.valve_open_percent
|
||||
if (
|
||||
dpercent >= -1 * self._auto_regulation_dpercent
|
||||
and dpercent < self._auto_regulation_dpercent
|
||||
):
|
||||
_LOGGER.debug(
|
||||
"%s - do not calculate TPI because regulation_dpercent (%.1f) is not exceeded",
|
||||
self,
|
||||
dpercent,
|
||||
)
|
||||
|
||||
return
|
||||
|
||||
if self._valve_open_percent == new_valve_percent:
|
||||
_LOGGER.debug("%s - no change in valve_open_percent.", self)
|
||||
return
|
||||
|
||||
self._valve_open_percent = new_valve_percent
|
||||
|
||||
for under in self._underlyings:
|
||||
under.set_valve_open_percent()
|
||||
|
||||
self._last_calculation_timestamp = now
|
||||
|
||||
self.update_custom_attributes()
|
||||
self.async_write_ha_state()
|
||||
|
||||
|
||||
Reference in New Issue