* Add step temperature in config * All testus ok * Keep the step of the VTherm and not the step of the underlying * Release 5.4.0 --------- Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
@@ -84,14 +84,15 @@ Ce composant personnalisé pour Home Assistant est une mise à niveau et est une
|
||||
|
||||
|
||||
>  _*Nouveautés*_
|
||||
> * **Release 5.4** : Ajout du pas de température [#311](https://github.com/jmcollin78/versatile_thermostat/issues/311).
|
||||
> * **Release 5.3** : Ajout d'une fonction de pilotage d'une chaudière centrale [#234](https://github.com/jmcollin78/versatile_thermostat/issues/234) - plus d'infos ici: [Le contrôle d'une chaudière centrale](#le-contrôle-dune-chaudière-centrale). Ajout de la possibilité de désactiver le mode sécurité pour le thermomètre extérieur [#343](https://github.com/jmcollin78/versatile_thermostat/issues/343)
|
||||
> * **Release 5.2** : Ajout d'un `central_mode` permettant de piloter tous les VTherms de façon centralisée [#158](https://github.com/jmcollin78/versatile_thermostat/issues/158).
|
||||
> * **Release 5.1** : Limitation des valeurs envoyées aux valves et au température envoyées au climate sous-jacent.
|
||||
> * **Release 5.0** : Ajout d'une configuration centrale permettant de mettre en commun les attributs qui peuvent l'être [#239](https://github.com/jmcollin78/versatile_thermostat/issues/239).
|
||||
> * **Release 4.3** : Ajout d'un mode auto-fan pour le type `over_climate` permettant d'activer la ventilation si l'écart de température est important [#223](https://github.com/jmcollin78/versatile_thermostat/issues/223).
|
||||
<details>
|
||||
<summary>Autres versions</summary>
|
||||
|
||||
> * **Release 4.3** : Ajout d'un mode auto-fan pour le type `over_climate` permettant d'activer la ventilation si l'écart de température est important [#223](https://github.com/jmcollin78/versatile_thermostat/issues/223).
|
||||
> * **Release 4.2** : Le calcul de la pente de la courbe de température se fait maintenant en °/heure et non plus en °/min [#242](https://github.com/jmcollin78/versatile_thermostat/issues/242). Correction de la détection automatique des ouvertures par l'ajout d'un lissage de la courbe de température .
|
||||
> * **Release 4.1** : Ajout d'un mode de régulation **Expert** dans lequel l'utilisateur peut spécifier ses propres paramètres d'auto-régulation au lieu d'utiliser les pre-programmés [#194](https://github.com/jmcollin78/versatile_thermostat/issues/194).
|
||||
> * **Release 4.0** : Ajout de la prise en charge de la **Versatile Thermostat UI Card**. Voir [Versatile Thermostat UI Card](https://github.com/jmcollin78/versatile-thermostat-ui-card). Ajout d'un mode de régulation **Slow** pour les appareils de chauffage à latence lente [#168](https://github.com/jmcollin78/versatile_thermostat/issues/168). Changement de la façon dont **la puissance est calculée** dans le cas de VTherm avec des équipements multi-sous-jacents [#146](https://github.com/jmcollin78/versatile_thermostat/issues/146). Ajout de la prise en charge de AC et Heat pour VTherm via un interrupteur également [#144](https://github.com/jmcollin78/versatile_thermostat/pull/144)
|
||||
@@ -127,7 +128,7 @@ En conséquence toute la phase de paramètrage d'un VTherm a été profondemment
|
||||
**Note :** les copies d'écran de la configuration d'un VTherm n'ont pas été mises à jour.
|
||||
|
||||
# Merci pour la bière [buymecoffee](https://www.buymeacoffee.com/jmcollin78)
|
||||
Un grand merci à @salabur, @pvince83, @bergoglio, @EPicLURcher, @ecolorado66, @Kriss1670, @maia, @f.maymil, @moutte69, @Jerome, @Gunnar M, @Greg.o, @John Burgess, @abyssmal, @capinfo26, @Helge, @MattG @Mexx62, @Someone, @Lajull pour les bières. Ca fait très plaisir et ça m'encourage à continuer !
|
||||
Un grand merci à @salabur, @pvince83, @bergoglio, @EPicLURcher, @ecolorado66, @Kriss1670, @maia, @f.maymil, @moutte69, @Jerome, @Gunnar M, @Greg.o, @John Burgess, @abyssmal, @capinfo26, @Helge, @MattG @Mexx62, @Someone, @Lajull, @giopeco pour les bières. Ca fait très plaisir et ça m'encourage à continuer !
|
||||
|
||||
|
||||
# Quand l'utiliser et ne pas l'utiliser
|
||||
|
||||
@@ -84,14 +84,15 @@
|
||||
This custom component for Home Assistant is an upgrade and is a complete rewrite of the component "Awesome thermostat" (see [Github](https://github.com/dadge/awesome_thermostat)) with addition of features.
|
||||
|
||||
> _*News*_
|
||||
> * **Release 5.4**: Added a temperature step [#311](https://github.com/jmcollin78/versatile_thermostat/issues/311).
|
||||
> * **Release 5.3**: Added a central boiler control function [#234](https://github.com/jmcollin78/versatile_thermostat/issues/234) - more information here: [Controlling a central boiler](#controlling-a-central-boiler). Added the ability to disable security mode for outdoor thermometer [#343](https://github.com/jmcollin78/versatile_thermostat/issues/343)
|
||||
> * **Release 5.2**: Added a `central_mode` allowing all VTherms to be controlled centrally [#158](https://github.com/jmcollin78/versatile_thermostat/issues/158).
|
||||
> * **Release 5.1**: Limitation of the values sent to the valves and the temperature sent to the underlying climate.
|
||||
> * **Release 5.0**: Added a central configuration allowing the sharing of attributes that can be shared [#239](https://github.com/jmcollin78/versatile_thermostat/issues/239).
|
||||
> * **Release 4.3**: Added an auto-fan mode for the `over_climate` type allowing ventilation to be activated if the temperature difference is significant [#223](https://github.com/jmcollin78/versatile_thermostat/issues/223).
|
||||
<details>
|
||||
<summary>Others releases</summary>
|
||||
|
||||
> * **Release 4.3**: Added an auto-fan mode for the `over_climate` type allowing ventilation to be activated if the temperature difference is significant [#223](https://github.com/jmcollin78/versatile_thermostat/issues/223).
|
||||
> * **Release 4.2**: The calculation of the slope of the temperature curve is now done in °/hour and no longer in °/min [#242](https://github.com/jmcollin78/versatile_thermostat/issues/242). Correction of automatic detection of openings by adding smoothing of the temperature curve.
|
||||
> * **Release 4.1**: Added an **Expert** regulation mode in which the user can specify their own auto-regulation parameters instead of using the pre-programmed ones [#194]( https://github.com/jmcollin78/versatile_thermostat/issues/194).
|
||||
> * **Release 4.0**: Added the support of **Versatile Thermostat UI Card**. See [Versatile Thermostat UI Card](https://github.com/jmcollin78/versatile-thermostat-ui-card). Added a **Slow** regulation mode for slow latency heating devices [#168](https://github.com/jmcollin78/versatile_thermostat/issues/168). Change the way **the power is calculated** in case of VTherm with multi-underlying equipements [#146](https://github.com/jmcollin78/versatile_thermostat/issues/146). Added the support of AC and Heat for VTherm over switch alse [#144](https://github.com/jmcollin78/versatile_thermostat/pull/144)
|
||||
@@ -127,7 +128,7 @@ Consequently, the entire configuration phase of a VTherm has been profoundly mod
|
||||
**Note:** the VTherm configuration screenshots have not been updated.
|
||||
|
||||
# Thanks for the beer [buymecoffee](https://www.buymeacoffee.com/jmcollin78)
|
||||
Many thanks to @salabur, @pvince83, @bergoglio, @EPicLURcher, @ecolorado66, @Kriss1670, @maia, @f.maymil, @moutte69, @Jerome, @Gunnar M, @Greg.o, @John Burgess, @abyssmal, @capinfo26, @Helge, @MattG, @MattG, @Mexx62, @Someone, @Lajull for the beers. It's very nice and encourages me to continue!
|
||||
Many thanks to @salabur, @pvince83, @bergoglio, @EPicLURcher, @ecolorado66, @Kriss1670, @maia, @f.maymil, @moutte69, @Jerome, @Gunnar M, @Greg.o, @John Burgess, @abyssmal, @capinfo26, @Helge, @MattG, @MattG, @Mexx62, @Someone, @Lajull, @giopeco for the beers. It's very nice and encourages me to continue!
|
||||
|
||||
# When to use / not use
|
||||
This thermostat can control 3 types of equipment:
|
||||
|
||||
@@ -355,6 +355,8 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
self._ac_mode = entry_infos.get(CONF_AC_MODE) is True
|
||||
self._attr_max_temp = entry_infos.get(CONF_TEMP_MAX)
|
||||
self._attr_min_temp = entry_infos.get(CONF_TEMP_MIN)
|
||||
if (step := entry_infos.get(CONF_STEP_TEMPERATURE)) is not None:
|
||||
self._attr_target_temperature_step = step
|
||||
|
||||
# convert entry_infos into usable attributes
|
||||
presets = {}
|
||||
@@ -400,8 +402,6 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
self._proportional_function = entry_infos.get(CONF_PROP_FUNCTION)
|
||||
self._temp_sensor_entity_id = entry_infos.get(CONF_TEMP_SENSOR)
|
||||
self._ext_temp_sensor_entity_id = entry_infos.get(CONF_EXTERNAL_TEMP_SENSOR)
|
||||
# Default value not configurable
|
||||
self._attr_target_temperature_step = 0.1
|
||||
self._power_sensor_entity_id = entry_infos.get(CONF_POWER_SENSOR)
|
||||
self._max_power_sensor_entity_id = entry_infos.get(CONF_MAX_POWER_SENSOR)
|
||||
self._window_sensor_entity_id = entry_infos.get(CONF_WINDOW_SENSOR)
|
||||
|
||||
@@ -61,6 +61,7 @@ STEP_CENTRAL_MAIN_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
),
|
||||
vol.Required(CONF_TEMP_MIN, default=7): vol.Coerce(float),
|
||||
vol.Required(CONF_TEMP_MAX, default=35): vol.Coerce(float),
|
||||
vol.Required(CONF_STEP_TEMPERATURE, default=0.1): vol.Coerce(float),
|
||||
vol.Required(CONF_ADD_CENTRAL_BOILER_CONTROL, default=False): cv.boolean,
|
||||
}
|
||||
)
|
||||
@@ -72,6 +73,7 @@ STEP_CENTRAL_SPEC_MAIN_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
),
|
||||
vol.Required(CONF_TEMP_MIN, default=7): vol.Coerce(float),
|
||||
vol.Required(CONF_TEMP_MAX, default=35): vol.Coerce(float),
|
||||
vol.Required(CONF_STEP_TEMPERATURE, default=0.1): vol.Coerce(float),
|
||||
}
|
||||
)
|
||||
|
||||
|
||||
@@ -112,6 +112,7 @@ CONF_AUTO_FAN_LOW = "auto_fan_low"
|
||||
CONF_AUTO_FAN_MEDIUM = "auto_fan_medium"
|
||||
CONF_AUTO_FAN_HIGH = "auto_fan_high"
|
||||
CONF_AUTO_FAN_TURBO = "auto_fan_turbo"
|
||||
CONF_STEP_TEMPERATURE = "step_temperature"
|
||||
|
||||
# Global params into configuration.yaml
|
||||
CONF_SHORT_EMA_PARAMS = "short_ema_params"
|
||||
@@ -270,6 +271,7 @@ ALL_CONF = (
|
||||
CONF_CENTRAL_BOILER_ACTIVATION_SRV,
|
||||
CONF_CENTRAL_BOILER_DEACTIVATION_SRV,
|
||||
CONF_WINDOW_ACTION,
|
||||
CONF_STEP_TEMPERATURE,
|
||||
]
|
||||
+ CONF_PRESETS_VALUES
|
||||
+ CONF_PRESETS_AWAY_VALUES
|
||||
|
||||
@@ -14,6 +14,6 @@
|
||||
"quality_scale": "silver",
|
||||
"requirements": [],
|
||||
"ssdp": [],
|
||||
"version": "5.3.0",
|
||||
"version": "5.4.0",
|
||||
"zeroconf": []
|
||||
}
|
||||
@@ -23,6 +23,7 @@
|
||||
"cycle_min": "Cycle duration (minutes)",
|
||||
"temp_min": "Minimal temperature allowed",
|
||||
"temp_max": "Maximal temperature allowed",
|
||||
"step_temperature": "Temperature step",
|
||||
"device_power": "Device power",
|
||||
"use_central_mode": "Enable the control by central entity (need central config). Check to enable the control of the VTherm with the select central_mode entities.",
|
||||
"use_window_feature": "Use window detection",
|
||||
@@ -257,6 +258,7 @@
|
||||
"cycle_min": "Cycle duration (minutes)",
|
||||
"temp_min": "Minimal temperature allowed",
|
||||
"temp_max": "Maximal temperature allowed",
|
||||
"step_temperature": "Temperature step",
|
||||
"device_power": "Device power",
|
||||
"use_central_mode": "Enable the control by central entity (need central config). Check to enable the control of the VTherm with the select central_mode entities.",
|
||||
"use_window_feature": "Use window detection",
|
||||
|
||||
@@ -850,13 +850,14 @@ class ThermostatOverClimate(BaseThermostat):
|
||||
|
||||
return self._support_flags
|
||||
|
||||
@property
|
||||
def target_temperature_step(self) -> float | None:
|
||||
"""Return the supported step of target temperature."""
|
||||
if self.underlying_entity(0):
|
||||
return self.underlying_entity(0).target_temperature_step
|
||||
|
||||
return None
|
||||
# We keep the step configured for the VTherm and not the step of the underlying
|
||||
# @property
|
||||
# def target_temperature_step(self) -> float | None:
|
||||
# """Return the supported step of target temperature."""
|
||||
# if self.underlying_entity(0):
|
||||
# return self.underlying_entity(0).target_temperature_step
|
||||
#
|
||||
# return None
|
||||
|
||||
@property
|
||||
def target_temperature_high(self) -> float | None:
|
||||
|
||||
@@ -23,6 +23,7 @@
|
||||
"cycle_min": "Cycle duration (minutes)",
|
||||
"temp_min": "Minimal temperature allowed",
|
||||
"temp_max": "Maximal temperature allowed",
|
||||
"step_temperature": "Temperature step",
|
||||
"device_power": "Device power",
|
||||
"use_central_mode": "Enable the control by central entity (need central config). Check to enable the control of the VTherm with the select central_mode entities.",
|
||||
"use_window_feature": "Use window detection",
|
||||
@@ -257,6 +258,7 @@
|
||||
"cycle_min": "Cycle duration (minutes)",
|
||||
"temp_min": "Minimal temperature allowed",
|
||||
"temp_max": "Maximal temperature allowed",
|
||||
"step_temperature": "Temperature step",
|
||||
"device_power": "Device power",
|
||||
"use_central_mode": "Enable the control by central entity (need central config). Check to enable the control of the VTherm with the select central_mode entities.",
|
||||
"use_window_feature": "Use window detection",
|
||||
|
||||
@@ -23,6 +23,7 @@
|
||||
"cycle_min": "Durée du cycle (minutes)",
|
||||
"temp_min": "Température minimale permise",
|
||||
"temp_max": "Température maximale permise",
|
||||
"step_temperature": "Pas de température",
|
||||
"device_power": "Puissance de l'équipement",
|
||||
"use_central_mode": "Autoriser le controle par une entity centrale ('nécessite une config. centrale`). Cochez pour autoriser le contrôle du VTherm par la liste déroulante 'central_mode' de l'entité configuration centrale.",
|
||||
"use_window_feature": "Avec détection des ouvertures",
|
||||
@@ -269,6 +270,7 @@
|
||||
"cycle_min": "Durée du cycle (minutes)",
|
||||
"temp_min": "Température minimale permise",
|
||||
"temp_max": "Température maximale permise",
|
||||
"step_temperature": "Pas de température",
|
||||
"device_power": "Puissance de l'équipement",
|
||||
"use_central_mode": "Autoriser le controle par une entity centrale ('nécessite une config. centrale`). Cochez pour autoriser le contrôle du VTherm par la liste déroulante 'central_mode' de l'entité configuration centrale.",
|
||||
"use_window_feature": "Avec détection des ouvertures",
|
||||
|
||||
@@ -146,6 +146,7 @@ FULL_CENTRAL_CONFIG = {
|
||||
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
|
||||
CONF_TEMP_MIN: 15,
|
||||
CONF_TEMP_MAX: 30,
|
||||
CONF_STEP_TEMPERATURE: 0.1,
|
||||
CONF_TPI_COEF_INT: 0.5,
|
||||
CONF_TPI_COEF_EXT: 0.02,
|
||||
"frost_temp": 10,
|
||||
@@ -186,6 +187,7 @@ FULL_CENTRAL_CONFIG_WITH_BOILER = {
|
||||
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
|
||||
CONF_TEMP_MIN: 15,
|
||||
CONF_TEMP_MAX: 30,
|
||||
CONF_STEP_TEMPERATURE: 0.1,
|
||||
CONF_TPI_COEF_INT: 0.5,
|
||||
CONF_TPI_COEF_EXT: 0.02,
|
||||
"frost_temp": 10,
|
||||
@@ -263,6 +265,7 @@ class MockClimate(ClimateEntity):
|
||||
self._attr_target_temperature = 20
|
||||
self._attr_current_temperature = 15
|
||||
self._attr_hvac_action = hvac_action
|
||||
self._attr_target_temperature_step = 0.2
|
||||
self._fan_modes = fan_modes if fan_modes else None
|
||||
self._attr_fan_mode = None
|
||||
|
||||
|
||||
@@ -33,6 +33,7 @@ MOCK_TH_OVER_4SWITCH_USER_CONFIG = {
|
||||
CONF_CYCLE_MIN: 8,
|
||||
CONF_TEMP_MIN: 15,
|
||||
CONF_TEMP_MAX: 30,
|
||||
CONF_STEP_TEMPERATURE: 0.1,
|
||||
CONF_DEVICE_POWER: 1,
|
||||
CONF_USE_WINDOW_FEATURE: True,
|
||||
CONF_USE_MOTION_FEATURE: True,
|
||||
@@ -59,6 +60,7 @@ MOCK_TH_OVER_CLIMATE_CENTRAL_MAIN_CONFIG = {
|
||||
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
|
||||
CONF_TEMP_MIN: 15,
|
||||
CONF_TEMP_MAX: 30,
|
||||
CONF_STEP_TEMPERATURE: 0.1,
|
||||
# Keep default values which are False
|
||||
}
|
||||
|
||||
@@ -66,6 +68,7 @@ MOCK_TH_OVER_SWITCH_CENTRAL_MAIN_CONFIG = {
|
||||
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
|
||||
CONF_TEMP_MIN: 15,
|
||||
CONF_TEMP_MAX: 30,
|
||||
CONF_STEP_TEMPERATURE: 0.1,
|
||||
# Keep default values which are False
|
||||
}
|
||||
|
||||
|
||||
@@ -591,6 +591,7 @@ async def test_bug_272(
|
||||
domain=DOMAIN,
|
||||
title="TheOverClimateMockName",
|
||||
unique_id="uniqueId",
|
||||
# default value are min 15°, max 30°, step 0.1
|
||||
data=PARTIAL_CLIMATE_CONFIG, # 5 minutes security delay
|
||||
)
|
||||
|
||||
@@ -623,6 +624,8 @@ async def test_bug_272(
|
||||
assert entity.name == "TheOverClimateMockName"
|
||||
assert entity.is_over_climate is True
|
||||
assert entity.hvac_mode is HVACMode.OFF
|
||||
# The VTherm value and not the underlying value
|
||||
assert entity.target_temperature_step == 0.1
|
||||
assert entity.target_temperature == entity.min_temp
|
||||
assert entity.is_regulated is True
|
||||
|
||||
|
||||
@@ -760,7 +760,7 @@ async def test_update_central_boiler_state_simple_climate(
|
||||
climate1.set_hvac_action(HVACAction.HEATING)
|
||||
climate1.async_write_ha_state()
|
||||
# Wait for state event propagation
|
||||
await asyncio.sleep(0.1)
|
||||
await asyncio.sleep(0.5)
|
||||
|
||||
assert entity.hvac_action == HVACAction.HEATING
|
||||
|
||||
@@ -801,7 +801,7 @@ async def test_update_central_boiler_state_simple_climate(
|
||||
climate1.set_hvac_action(HVACAction.IDLE)
|
||||
climate1.async_write_ha_state()
|
||||
# Wait for state event propagation
|
||||
await asyncio.sleep(0.1)
|
||||
await asyncio.sleep(0.5)
|
||||
|
||||
assert entity.hvac_action == HVACAction.IDLE
|
||||
|
||||
|
||||
@@ -106,7 +106,7 @@ async def test_add_a_central_config(hass: HomeAssistant, skip_hass_states_is_sta
|
||||
|
||||
|
||||
# @pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
# @pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
async def test_minimal_over_switch_wo_central_config(
|
||||
hass: HomeAssistant, skip_hass_states_is_state, init_vtherm_api
|
||||
):
|
||||
@@ -124,6 +124,7 @@ async def test_minimal_over_switch_wo_central_config(
|
||||
CONF_CYCLE_MIN: 5,
|
||||
CONF_TEMP_MIN: 8,
|
||||
CONF_TEMP_MAX: 18,
|
||||
CONF_STEP_TEMPERATURE: 0.3,
|
||||
"frost_temp": 10,
|
||||
"eco_temp": 17,
|
||||
"comfort_temp": 18,
|
||||
@@ -165,8 +166,9 @@ async def test_minimal_over_switch_wo_central_config(
|
||||
assert entity._temp_sensor_entity_id == "sensor.mock_temp_sensor"
|
||||
assert entity._ext_temp_sensor_entity_id == "sensor.mock_ext_temp_sensor"
|
||||
assert entity._cycle_min == 5
|
||||
assert entity._attr_min_temp == 8
|
||||
assert entity._attr_max_temp == 18
|
||||
assert entity.min_temp == 8
|
||||
assert entity.max_temp == 18
|
||||
assert entity.target_temperature_step == 0.3
|
||||
assert entity.preset_modes == ["none", "frost", "eco", "comfort", "boost"]
|
||||
assert entity.is_window_auto_enabled is False
|
||||
assert entity.nb_underlying_entities == 1
|
||||
@@ -202,6 +204,7 @@ async def test_full_over_switch_wo_central_config(
|
||||
CONF_CYCLE_MIN: 5,
|
||||
CONF_TEMP_MIN: 8,
|
||||
CONF_TEMP_MAX: 18,
|
||||
CONF_STEP_TEMPERATURE: 0.3,
|
||||
"frost_temp": 10,
|
||||
"eco_temp": 17,
|
||||
"comfort_temp": 18,
|
||||
@@ -257,8 +260,9 @@ async def test_full_over_switch_wo_central_config(
|
||||
assert entity._temp_sensor_entity_id == "sensor.mock_temp_sensor"
|
||||
assert entity._ext_temp_sensor_entity_id == "sensor.mock_ext_temp_sensor"
|
||||
assert entity._cycle_min == 5
|
||||
assert entity._attr_min_temp == 8
|
||||
assert entity._attr_max_temp == 18
|
||||
assert entity.min_temp == 8
|
||||
assert entity.max_temp == 18
|
||||
assert entity.target_temperature_step == 0.3
|
||||
assert entity.preset_modes == [
|
||||
"none",
|
||||
"frost",
|
||||
@@ -318,6 +322,7 @@ async def test_full_over_switch_with_central_config(
|
||||
CONF_CYCLE_MIN: 5,
|
||||
CONF_TEMP_MIN: 8,
|
||||
CONF_TEMP_MAX: 18,
|
||||
CONF_STEP_TEMPERATURE: 0.3,
|
||||
"frost_temp": 10,
|
||||
"eco_temp": 17,
|
||||
"comfort_temp": 18,
|
||||
@@ -369,8 +374,9 @@ async def test_full_over_switch_with_central_config(
|
||||
assert entity._temp_sensor_entity_id == "sensor.mock_temp_sensor"
|
||||
assert entity._ext_temp_sensor_entity_id == "sensor.mock_ext_temp_sensor"
|
||||
assert entity._cycle_min == 5
|
||||
assert entity._attr_min_temp == 15
|
||||
assert entity._attr_max_temp == 30
|
||||
assert entity.min_temp == 15
|
||||
assert entity.max_temp == 30
|
||||
assert entity.target_temperature_step == 0.1
|
||||
assert entity.preset_modes == [
|
||||
"none",
|
||||
"frost",
|
||||
|
||||
Reference in New Issue