Bug #121 loop in over climate
* Issue #121 - loop when underlying is slow * Issue #121 - try fix * Release 3.5.3 * Fix tests step
This commit is contained in:
6
.github/workflows/pull.yml
vendored
6
.github/workflows/pull.yml
vendored
@@ -31,6 +31,8 @@ jobs:
|
||||
- run: black .
|
||||
|
||||
tests:
|
||||
# Tests don't run in Gitlab ci environment
|
||||
if: 0
|
||||
runs-on: "ubuntu-latest"
|
||||
name: Run tests
|
||||
steps:
|
||||
@@ -41,10 +43,10 @@ jobs:
|
||||
with:
|
||||
python-version: "3.8"
|
||||
- name: Install requirements
|
||||
run: python3 -m pip install -r requirements_test.txt
|
||||
run: cd custom_components/versatile_thermostat && python3 -m pip install -r requirements_test.txt
|
||||
- name: Run tests
|
||||
run: |
|
||||
pytest \
|
||||
cd custom_components/versatile_thermostat && pytest \
|
||||
-qq \
|
||||
--timeout=9 \
|
||||
--durations=10 \
|
||||
|
||||
@@ -220,6 +220,7 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
_presence_state: bool
|
||||
_window_auto_state: bool
|
||||
_underlyings: list[UnderlyingEntity]
|
||||
_last_change_time: datetime
|
||||
|
||||
def __init__(self, hass: HomeAssistant, unique_id, name, entry_infos) -> None:
|
||||
"""Initialize the thermostat."""
|
||||
@@ -284,6 +285,8 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
|
||||
self._current_tz = dt_util.get_time_zone(self._hass.config.time_zone)
|
||||
|
||||
self._last_change_time = None
|
||||
|
||||
self._underlyings = []
|
||||
|
||||
self.post_init(entry_infos)
|
||||
@@ -778,6 +781,8 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
else:
|
||||
self.hass.create_task(self._async_control_heating())
|
||||
|
||||
self.reset_last_change_time()
|
||||
|
||||
await self.get_my_previous_state()
|
||||
|
||||
if self.hass.state == CoreState.running:
|
||||
@@ -951,7 +956,6 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
"""Return current operation."""
|
||||
# Issue #114 - returns my current hvac_mode and not the underlying hvac_mode which could be different
|
||||
# delta will be managed by climate_state_change event.
|
||||
# TODO remove this when ok
|
||||
# if self._is_over_climate:
|
||||
# if one not OFF -> return it
|
||||
# else OFF
|
||||
@@ -1233,6 +1237,8 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
# Ensure we update the current operation after changing the mode
|
||||
self.reset_last_temperature_time()
|
||||
|
||||
self.reset_last_change_time()
|
||||
|
||||
self.update_custom_attributes()
|
||||
self.async_write_ha_state()
|
||||
self.send_event(EventType.HVAC_MODE_EVENT, {"hvac_mode": self._hvac_mode})
|
||||
@@ -1288,6 +1294,11 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
self.recalculate()
|
||||
self.send_event(EventType.PRESET_EVENT, {"preset": self._attr_preset_mode})
|
||||
|
||||
def reset_last_change_time(self, old_preset_mode=None):
|
||||
"""Reset to now the last change time"""
|
||||
self._last_change_time = datetime.now(tz=self._current_tz)
|
||||
_LOGGER.debug("%s - last_change_time is now %s", self, self._last_change_time)
|
||||
|
||||
def reset_last_temperature_time(self, old_preset_mode=None):
|
||||
"""Reset to now the last temperature time if conditions are satisfied"""
|
||||
if (
|
||||
@@ -1363,6 +1374,7 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
await self._async_internal_set_temperature(temperature)
|
||||
self._attr_preset_mode = PRESET_NONE
|
||||
self.recalculate()
|
||||
self.reset_last_change_time()
|
||||
await self._async_control_heating(force=True)
|
||||
|
||||
async def _async_internal_set_temperature(self, temperature):
|
||||
@@ -1585,7 +1597,22 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
|
||||
@callback
|
||||
async def _async_climate_changed(self, event):
|
||||
"""Handle unerdlying climate state changes."""
|
||||
"""Handle unerdlying climate state changes.
|
||||
This method takes the underlying values and update the VTherm with them.
|
||||
To avoid loops (issues #121 #101 #95 #99), we discard the event if it is received
|
||||
less than 10 sec after the last command. What we want here is to take the values
|
||||
from underlyings ONLY if someone have change directly on the underlying and not
|
||||
as a return of the command. The only thing we take all the time is the HVACAction
|
||||
which is important for feedaback and which cannot generates loops.
|
||||
"""
|
||||
|
||||
async def end_climate_changed(changes):
|
||||
""" To end the event management"""
|
||||
if changes:
|
||||
self.async_write_ha_state()
|
||||
self.update_custom_attributes()
|
||||
await self._async_control_heating()
|
||||
|
||||
new_state = event.data.get("new_state")
|
||||
_LOGGER.debug("%s - _async_climate_changed new_state is %s", self, new_state)
|
||||
if not new_state:
|
||||
@@ -1606,6 +1633,11 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
else None
|
||||
)
|
||||
|
||||
old_state_date_changed = old_state.last_changed if old_state and old_state.last_changed else None
|
||||
old_state_date_updated = old_state.last_updated if old_state and old_state.last_updated else None
|
||||
new_state_date_changed = new_state.last_changed if new_state and new_state.last_changed else None
|
||||
new_state_date_updated = new_state.last_updated if new_state and new_state.last_updated else None
|
||||
|
||||
# Issue 99 - some AC turn hvac_mode=cool and hvac_action=idle when sending a HVACMode_OFF command
|
||||
# Issue 114 - Remove this because hvac_mode is now managed by local _hvac_mode and use idle action as is
|
||||
#if self._hvac_mode == HVACMode.OFF and new_hvac_action == HVACAction.IDLE:
|
||||
@@ -1621,24 +1653,9 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
old_hvac_action,
|
||||
)
|
||||
|
||||
if new_hvac_mode in [
|
||||
HVACMode.OFF,
|
||||
HVACMode.HEAT,
|
||||
HVACMode.COOL,
|
||||
HVACMode.HEAT_COOL,
|
||||
HVACMode.DRY,
|
||||
HVACMode.AUTO,
|
||||
HVACMode.FAN_ONLY,
|
||||
None
|
||||
] and self._hvac_mode != new_hvac_mode:
|
||||
changes = True
|
||||
self._hvac_mode = new_hvac_mode
|
||||
# Do not try to update all underlying state, else we will have a loop
|
||||
if self._is_over_climate:
|
||||
for under in self._underlyings:
|
||||
await under.set_hvac_mode(new_hvac_mode)
|
||||
_LOGGER.debug("%s - last_change_time=%s old_state_date_changed=%s old_state_date_updated=%s new_state_date_changed=%s new_state_date_updated=%s", self, self._last_change_time, old_state_date_changed, old_state_date_updated, new_state_date_changed, new_state_date_updated)
|
||||
|
||||
# Interpretation of hvac
|
||||
# Interpretation of hvac action
|
||||
HVAC_ACTION_ON = [ # pylint: disable=invalid-name
|
||||
HVACAction.COOLING,
|
||||
HVACAction.DRYING,
|
||||
@@ -1677,18 +1694,43 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
)
|
||||
changes = True
|
||||
|
||||
# Issue #120 - Some TRV are chaning target temperature a very long time (6 sec) after the change.
|
||||
# In that case a loop is possible if a user change multiple times during this 6 sec.
|
||||
if new_state_date_updated and self._last_change_time:
|
||||
delta = (new_state_date_updated - self._last_change_time).total_seconds()
|
||||
if delta < 10:
|
||||
_LOGGER.info("%s - underlying event is received less than 10 sec after command. Forget it to avoid loop", self
|
||||
)
|
||||
await end_climate_changed(changes)
|
||||
return
|
||||
|
||||
if new_hvac_mode in [
|
||||
HVACMode.OFF,
|
||||
HVACMode.HEAT,
|
||||
HVACMode.COOL,
|
||||
HVACMode.HEAT_COOL,
|
||||
HVACMode.DRY,
|
||||
HVACMode.AUTO,
|
||||
HVACMode.FAN_ONLY,
|
||||
None
|
||||
] and self._hvac_mode != new_hvac_mode:
|
||||
changes = True
|
||||
self._hvac_mode = new_hvac_mode
|
||||
# Update all underlyings state
|
||||
if self._is_over_climate:
|
||||
for under in self._underlyings:
|
||||
await under.set_hvac_mode(new_hvac_mode)
|
||||
|
||||
if not changes:
|
||||
# try to manage new target temperature set if state
|
||||
_LOGGER.debug("Do temperature check. temperature is %s, new_state.attributes is %s", self.target_temperature, new_state.attributes)
|
||||
if self._is_over_climate and new_state.attributes and (new_target_temp := new_state.attributes.get("temperature")) and new_target_temp != self.target_temperature:
|
||||
_LOGGER.info("%s - Target temp have change to %s", self, new_target_temp)
|
||||
_LOGGER.info("%s - Target temp in underlying have change to %s", self, new_target_temp)
|
||||
await self.async_set_temperature(temperature = new_target_temp)
|
||||
changes = True
|
||||
|
||||
if changes:
|
||||
self.async_write_ha_state()
|
||||
self.update_custom_attributes()
|
||||
await self._async_control_heating()
|
||||
await end_climate_changed(changes)
|
||||
|
||||
|
||||
@callback
|
||||
async def _async_update_temp(self, state: State):
|
||||
@@ -2103,9 +2145,6 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
now - self._last_ext_temperature_mesure.replace(tzinfo=self._current_tz)
|
||||
).total_seconds() / 60.0
|
||||
|
||||
# TODO before change:
|
||||
# mode_cond = self._is_over_climate or self._hvac_mode != HVACMode.OFF
|
||||
# fixed into this. Why if _is_over_climate we could into security even if HVACMode is OFF ?
|
||||
mode_cond = self._hvac_mode != HVACMode.OFF
|
||||
|
||||
temp_cond: bool = (
|
||||
@@ -2387,7 +2426,7 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
"window_auto_max_duration": self._window_auto_max_duration,
|
||||
}
|
||||
if self._is_over_climate:
|
||||
self._attr_extra_state_attributes["underlying_climate_1"] = self._underlyings[
|
||||
self._attr_extra_state_attributes["underlying_climate_0"] = self._underlyings[
|
||||
0
|
||||
].entity_id
|
||||
self._attr_extra_state_attributes["underlying_climate_1"] = self._underlyings[
|
||||
|
||||
@@ -14,6 +14,6 @@
|
||||
"quality_scale": "silver",
|
||||
"requirements": [],
|
||||
"ssdp": [],
|
||||
"version": "3.0.0",
|
||||
"version": "3.5.3",
|
||||
"zeroconf": []
|
||||
}
|
||||
@@ -1,2 +1,2 @@
|
||||
homeassistant==2023.10.1
|
||||
homeassistant==2023.10.3
|
||||
ffmpeg
|
||||
@@ -1,4 +1,5 @@
|
||||
-r requirements_dev.txt
|
||||
# For automatic run of test in Gitlab CI, we must not include other things that pytest-homeassistant-custom-component
|
||||
#-r requirements_dev.txt
|
||||
# aiodiscover
|
||||
ulid_transform
|
||||
# ulid_transform
|
||||
pytest-homeassistant-custom-component
|
||||
@@ -530,9 +530,16 @@ async def test_bug_101(
|
||||
await entity.async_set_preset_mode(PRESET_COMFORT)
|
||||
assert entity.preset_mode == PRESET_COMFORT
|
||||
|
||||
# 2. Change the target temp of underlying thermostat
|
||||
# 2. Change the target temp of underlying thermostat at now -> the event will be disgarded because to fast (to avoid loop cf issue 121)
|
||||
await send_climate_change_event_with_temperature(entity, HVACMode.HEAT, HVACMode.HEAT, HVACAction.OFF, HVACAction.OFF, now, 12.75)
|
||||
# Should have been switched to Manual preset
|
||||
# Should NOT have been switched to Manual preset
|
||||
assert entity.target_temperature == 17
|
||||
assert entity.preset_mode is PRESET_COMFORT
|
||||
|
||||
# 2. Change the target temp of underlying thermostat at 11 sec later -> the event will be taken
|
||||
# Wait 11 sec
|
||||
event_timestamp = now + timedelta(seconds=11)
|
||||
await send_climate_change_event_with_temperature(entity, HVACMode.HEAT, HVACMode.HEAT, HVACAction.OFF, HVACAction.OFF, event_timestamp, 12.75)
|
||||
assert entity.target_temperature == 12.75
|
||||
assert entity.preset_mode is PRESET_NONE
|
||||
|
||||
|
||||
@@ -163,7 +163,7 @@ async def test_one_switch_cycle(
|
||||
await asyncio.sleep(0.1)
|
||||
|
||||
assert mock_heater_on.call_count == 1
|
||||
# TODO normal ? assert entity.underlying_entity(0)._should_relaunch_control_heating is False
|
||||
# normal ? assert entity.underlying_entity(0)._should_relaunch_control_heating is False
|
||||
|
||||
# Simulate the end of heater on cycle
|
||||
event_timestamp = now - timedelta(minutes=3)
|
||||
@@ -522,7 +522,9 @@ async def test_multiple_climates_underlying_changes(
|
||||
), patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.set_hvac_mode"
|
||||
) as mock_underlying_set_hvac_mode:
|
||||
await send_climate_change_event(entity, HVACMode.OFF, HVACMode.HEAT, HVACAction.OFF, HVACAction.HEATING, now)
|
||||
# Wait 11 sec so that the event will not be discarded
|
||||
event_timestamp = now + timedelta(seconds=11)
|
||||
await send_climate_change_event(entity, HVACMode.OFF, HVACMode.HEAT, HVACAction.OFF, HVACAction.HEATING, event_timestamp)
|
||||
|
||||
# Should be call for all Switch
|
||||
assert mock_underlying_set_hvac_mode.call_count == 4
|
||||
@@ -543,7 +545,9 @@ async def test_multiple_climates_underlying_changes(
|
||||
# notice that there is no need of return_value=HVACAction.IDLE because this is not a function but a property
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.hvac_action", HVACAction.IDLE
|
||||
) as mock_underlying_get_hvac_action:
|
||||
await send_climate_change_event(entity, HVACMode.HEAT, HVACMode.OFF, HVACAction.IDLE, HVACAction.OFF, now)
|
||||
# Wait 11 sec so that the event will not be discarded
|
||||
event_timestamp = now + timedelta(seconds=11)
|
||||
await send_climate_change_event(entity, HVACMode.HEAT, HVACMode.OFF, HVACAction.IDLE, HVACAction.OFF, event_timestamp)
|
||||
|
||||
# Should be call for all Switch
|
||||
assert mock_underlying_set_hvac_mode.call_count == 4
|
||||
|
||||
Reference in New Issue