* Add step temperature in config * All testus ok * Keep the step of the VTherm and not the step of the underlying * Release 5.4.0 --------- Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
@@ -355,6 +355,8 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
self._ac_mode = entry_infos.get(CONF_AC_MODE) is True
|
||||
self._attr_max_temp = entry_infos.get(CONF_TEMP_MAX)
|
||||
self._attr_min_temp = entry_infos.get(CONF_TEMP_MIN)
|
||||
if (step := entry_infos.get(CONF_STEP_TEMPERATURE)) is not None:
|
||||
self._attr_target_temperature_step = step
|
||||
|
||||
# convert entry_infos into usable attributes
|
||||
presets = {}
|
||||
@@ -400,8 +402,6 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
self._proportional_function = entry_infos.get(CONF_PROP_FUNCTION)
|
||||
self._temp_sensor_entity_id = entry_infos.get(CONF_TEMP_SENSOR)
|
||||
self._ext_temp_sensor_entity_id = entry_infos.get(CONF_EXTERNAL_TEMP_SENSOR)
|
||||
# Default value not configurable
|
||||
self._attr_target_temperature_step = 0.1
|
||||
self._power_sensor_entity_id = entry_infos.get(CONF_POWER_SENSOR)
|
||||
self._max_power_sensor_entity_id = entry_infos.get(CONF_MAX_POWER_SENSOR)
|
||||
self._window_sensor_entity_id = entry_infos.get(CONF_WINDOW_SENSOR)
|
||||
|
||||
@@ -61,6 +61,7 @@ STEP_CENTRAL_MAIN_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
),
|
||||
vol.Required(CONF_TEMP_MIN, default=7): vol.Coerce(float),
|
||||
vol.Required(CONF_TEMP_MAX, default=35): vol.Coerce(float),
|
||||
vol.Required(CONF_STEP_TEMPERATURE, default=0.1): vol.Coerce(float),
|
||||
vol.Required(CONF_ADD_CENTRAL_BOILER_CONTROL, default=False): cv.boolean,
|
||||
}
|
||||
)
|
||||
@@ -72,6 +73,7 @@ STEP_CENTRAL_SPEC_MAIN_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
),
|
||||
vol.Required(CONF_TEMP_MIN, default=7): vol.Coerce(float),
|
||||
vol.Required(CONF_TEMP_MAX, default=35): vol.Coerce(float),
|
||||
vol.Required(CONF_STEP_TEMPERATURE, default=0.1): vol.Coerce(float),
|
||||
}
|
||||
)
|
||||
|
||||
|
||||
@@ -112,6 +112,7 @@ CONF_AUTO_FAN_LOW = "auto_fan_low"
|
||||
CONF_AUTO_FAN_MEDIUM = "auto_fan_medium"
|
||||
CONF_AUTO_FAN_HIGH = "auto_fan_high"
|
||||
CONF_AUTO_FAN_TURBO = "auto_fan_turbo"
|
||||
CONF_STEP_TEMPERATURE = "step_temperature"
|
||||
|
||||
# Global params into configuration.yaml
|
||||
CONF_SHORT_EMA_PARAMS = "short_ema_params"
|
||||
@@ -270,6 +271,7 @@ ALL_CONF = (
|
||||
CONF_CENTRAL_BOILER_ACTIVATION_SRV,
|
||||
CONF_CENTRAL_BOILER_DEACTIVATION_SRV,
|
||||
CONF_WINDOW_ACTION,
|
||||
CONF_STEP_TEMPERATURE,
|
||||
]
|
||||
+ CONF_PRESETS_VALUES
|
||||
+ CONF_PRESETS_AWAY_VALUES
|
||||
|
||||
@@ -14,6 +14,6 @@
|
||||
"quality_scale": "silver",
|
||||
"requirements": [],
|
||||
"ssdp": [],
|
||||
"version": "5.3.0",
|
||||
"version": "5.4.0",
|
||||
"zeroconf": []
|
||||
}
|
||||
@@ -23,6 +23,7 @@
|
||||
"cycle_min": "Cycle duration (minutes)",
|
||||
"temp_min": "Minimal temperature allowed",
|
||||
"temp_max": "Maximal temperature allowed",
|
||||
"step_temperature": "Temperature step",
|
||||
"device_power": "Device power",
|
||||
"use_central_mode": "Enable the control by central entity (need central config). Check to enable the control of the VTherm with the select central_mode entities.",
|
||||
"use_window_feature": "Use window detection",
|
||||
@@ -257,6 +258,7 @@
|
||||
"cycle_min": "Cycle duration (minutes)",
|
||||
"temp_min": "Minimal temperature allowed",
|
||||
"temp_max": "Maximal temperature allowed",
|
||||
"step_temperature": "Temperature step",
|
||||
"device_power": "Device power",
|
||||
"use_central_mode": "Enable the control by central entity (need central config). Check to enable the control of the VTherm with the select central_mode entities.",
|
||||
"use_window_feature": "Use window detection",
|
||||
|
||||
@@ -850,13 +850,14 @@ class ThermostatOverClimate(BaseThermostat):
|
||||
|
||||
return self._support_flags
|
||||
|
||||
@property
|
||||
def target_temperature_step(self) -> float | None:
|
||||
"""Return the supported step of target temperature."""
|
||||
if self.underlying_entity(0):
|
||||
return self.underlying_entity(0).target_temperature_step
|
||||
|
||||
return None
|
||||
# We keep the step configured for the VTherm and not the step of the underlying
|
||||
# @property
|
||||
# def target_temperature_step(self) -> float | None:
|
||||
# """Return the supported step of target temperature."""
|
||||
# if self.underlying_entity(0):
|
||||
# return self.underlying_entity(0).target_temperature_step
|
||||
#
|
||||
# return None
|
||||
|
||||
@property
|
||||
def target_temperature_high(self) -> float | None:
|
||||
|
||||
@@ -23,6 +23,7 @@
|
||||
"cycle_min": "Cycle duration (minutes)",
|
||||
"temp_min": "Minimal temperature allowed",
|
||||
"temp_max": "Maximal temperature allowed",
|
||||
"step_temperature": "Temperature step",
|
||||
"device_power": "Device power",
|
||||
"use_central_mode": "Enable the control by central entity (need central config). Check to enable the control of the VTherm with the select central_mode entities.",
|
||||
"use_window_feature": "Use window detection",
|
||||
@@ -257,6 +258,7 @@
|
||||
"cycle_min": "Cycle duration (minutes)",
|
||||
"temp_min": "Minimal temperature allowed",
|
||||
"temp_max": "Maximal temperature allowed",
|
||||
"step_temperature": "Temperature step",
|
||||
"device_power": "Device power",
|
||||
"use_central_mode": "Enable the control by central entity (need central config). Check to enable the control of the VTherm with the select central_mode entities.",
|
||||
"use_window_feature": "Use window detection",
|
||||
|
||||
@@ -23,6 +23,7 @@
|
||||
"cycle_min": "Durée du cycle (minutes)",
|
||||
"temp_min": "Température minimale permise",
|
||||
"temp_max": "Température maximale permise",
|
||||
"step_temperature": "Pas de température",
|
||||
"device_power": "Puissance de l'équipement",
|
||||
"use_central_mode": "Autoriser le controle par une entity centrale ('nécessite une config. centrale`). Cochez pour autoriser le contrôle du VTherm par la liste déroulante 'central_mode' de l'entité configuration centrale.",
|
||||
"use_window_feature": "Avec détection des ouvertures",
|
||||
@@ -269,6 +270,7 @@
|
||||
"cycle_min": "Durée du cycle (minutes)",
|
||||
"temp_min": "Température minimale permise",
|
||||
"temp_max": "Température maximale permise",
|
||||
"step_temperature": "Pas de température",
|
||||
"device_power": "Puissance de l'équipement",
|
||||
"use_central_mode": "Autoriser le controle par une entity centrale ('nécessite une config. centrale`). Cochez pour autoriser le contrôle du VTherm par la liste déroulante 'central_mode' de l'entité configuration centrale.",
|
||||
"use_window_feature": "Avec détection des ouvertures",
|
||||
|
||||