Release 3.1.0
This commit is contained in:
@@ -275,6 +275,8 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
self._underlying_climate_start_hvac_action_date = None
|
||||
self._underlying_climate_delta_t = 0
|
||||
|
||||
self._window_sensor_entity_id = None
|
||||
self._window_delay_sec = None
|
||||
self._window_auto_open_threshold = 0
|
||||
self._window_auto_close_threshold = 0
|
||||
self._window_auto_max_duration = 0
|
||||
@@ -1910,10 +1912,23 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
if (
|
||||
self._window_auto_algo.is_window_open_detected()
|
||||
and self._window_auto_state is False
|
||||
and self.hvac_mode != HVACMode.OFF
|
||||
):
|
||||
if (
|
||||
not self.proportional_algorithm
|
||||
or self.proportional_algorithm.on_percent <= 0.0
|
||||
):
|
||||
_LOGGER.info(
|
||||
"%s - Start auto detection of open window slope=%.3f but no heating detected (on_percent<=0). Forget the event",
|
||||
self,
|
||||
slope,
|
||||
)
|
||||
return dearm_window_auto
|
||||
|
||||
_LOGGER.warning(
|
||||
"%s - Start auto detection of open window slope=%.3f", self, slope
|
||||
)
|
||||
|
||||
# Send an event
|
||||
self.send_event(
|
||||
EventType.WINDOW_AUTO_EVENT,
|
||||
@@ -2418,6 +2433,7 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
"motion_state": self._motion_state,
|
||||
"overpowering_state": self._overpowering_state,
|
||||
"presence_state": self._presence_state,
|
||||
"window_auto_state": self._window_auto_state,
|
||||
"security_delay_min": self._security_delay_min,
|
||||
"security_min_on_percent": self._security_min_on_percent,
|
||||
"security_default_on_percent": self._security_default_on_percent,
|
||||
@@ -2436,6 +2452,10 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
.astimezone(self._current_tz)
|
||||
.isoformat(),
|
||||
"timezone": str(self._current_tz),
|
||||
"window_delay_sec": self._window_delay_sec,
|
||||
"window_auto_open_threshold": self._window_auto_open_threshold,
|
||||
"window_auto_close_threshold": self._window_auto_close_threshold,
|
||||
"window_auto_max_duration": self._window_auto_max_duration,
|
||||
}
|
||||
if self._is_over_climate:
|
||||
self._attr_extra_state_attributes[
|
||||
|
||||
@@ -59,6 +59,7 @@
|
||||
},
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "Leave empty if no window sensor should be use",
|
||||
"window_delay": "The delay in seconds before sensor detection is taken into account",
|
||||
"window_auto_open_threshold": "Recommended value: between 0.05 and 0.1. Leave empty if automatic window open detection is not use",
|
||||
"window_auto_close_threshold": "Recommended value: 0. Leave empty if automatic window open detection is not use",
|
||||
"window_auto_max_duration": "Recommended value: 60 (one hour). Leave empty if automatic window open detection is not use"
|
||||
@@ -97,10 +98,16 @@
|
||||
"title": "Advanced parameters",
|
||||
"description": "Configuration of advanced parameters. Leave the default values if you don't know what you are doing.\nThis parameters can lead to a very bad temperature or power regulation.",
|
||||
"data": {
|
||||
"minimal_activation_delay": "Delay in secondes under which the equipment will not be activated",
|
||||
"security_delay_min": "Maximum allowed delay in minutes between two temperature mesures. Above this delay, the thermostat will turn to a sceurity off state",
|
||||
"security_min_on_percent": "Minimal heating percent value for security preset activation. Below this amount of on_percent the thermostat won't go into security preset",
|
||||
"security_default_on_percent": "The default heating percent value in security preset. Set to 0 to switch off heater in security present"
|
||||
"minimal_activation_delay": "Minimal activation delay",
|
||||
"security_delay_min": "Security delay (in minutes)",
|
||||
"security_min_on_percent": "Minimal power percent for security mode",
|
||||
"security_default_on_percent": "Power percent to use in security mode"
|
||||
},
|
||||
"data_description": {
|
||||
"minimal_activation_delay": "Delay in seconds under which the equipment will not be activated",
|
||||
"security_delay_min": "Maximum allowed delay in minutes between two temperature mesures. Above this delay, the thermostat will turn to a security off state",
|
||||
"security_min_on_percent": "Minimal heating percent value for security preset activation. Below this amount of power percent the thermostat won't go into security preset",
|
||||
"security_default_on_percent": "The default heating power percent value in security preset. Set to 0 to switch off heater in security present"
|
||||
}
|
||||
}
|
||||
},
|
||||
@@ -161,20 +168,21 @@
|
||||
}
|
||||
},
|
||||
"window": {
|
||||
"title": "[%key:component::versatile_thermostat::config::step::window::title%]",
|
||||
"description": "[%key:component::versatile_thermostat::config::step::window::description%]",
|
||||
"title": "Window management",
|
||||
"description": "Open window management.\nLeave corresponding entity_id empty if not used\nYou can also configure automatic window open detection based on temperature decrease",
|
||||
"data": {
|
||||
"window_sensor_entity_id": "[%key:component::versatile_thermostat::config::step::window::data::window_sensor_entity_id%]",
|
||||
"window_delay": "[%key:component::versatile_thermostat::config::step::window::data::window_delay%]",
|
||||
"window_auto_open_threshold": "[%key:component::versatile_thermostat::config::step::window::data::window_auto_open_threshold%]",
|
||||
"window_auto_close_threshold": "[%key:component::versatile_thermostat::config::step::window::data::window_auto_close_threshold%]",
|
||||
"window_auto_max_duration": "[%key:component::versatile_thermostat::config::step::window::data::window_auto_max_duration%]"
|
||||
"window_sensor_entity_id": "Window sensor entity id",
|
||||
"window_delay": "Window sensor delay (seconds)",
|
||||
"window_auto_open_threshold": "Temperature decrease threshold for automatic window open detection (in °/min)",
|
||||
"window_auto_close_threshold": "Temperature increase threshold for end of automatic detection (in °/min)",
|
||||
"window_auto_max_duration": "Maximum duration of automatic window open detection (in min)"
|
||||
},
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "[%key:component::versatile_thermostat::config::step::window::data_description::window_sensor_entity_id%]",
|
||||
"window_auto_open_threshold": "[%key:component::versatile_thermostat::config::step::window::data_description::window_auto_open_threshold%]",
|
||||
"window_auto_close_threshold": "[%key:component::versatile_thermostat::config::step::window::data_description::window_auto_close_threshold%]",
|
||||
"window_auto_max_duration": "[%key:component::versatile_thermostat::config::step::window::data_description::window_auto_max_duration%]"
|
||||
"window_sensor_entity_id": "Leave empty if no window sensor should be use",
|
||||
"window_delay": "The delay in seconds before sensor detection is taken into account",
|
||||
"window_auto_open_threshold": "Recommended value: between 0.05 and 0.1. Leave empty if automatic window open detection is not use",
|
||||
"window_auto_close_threshold": "Recommended value: 0. Leave empty if automatic window open detection is not use",
|
||||
"window_auto_max_duration": "Recommended value: 60 (one hour). Leave empty if automatic window open detection is not use"
|
||||
}
|
||||
},
|
||||
"motion": {
|
||||
@@ -210,20 +218,26 @@
|
||||
"title": "Advanced parameters",
|
||||
"description": "Configuration of advanced parameters. Leave the default values if you don't know what you are doing.\nThis parameters can lead to a very bad temperature or power regulation.",
|
||||
"data": {
|
||||
"minimal_activation_delay": "Delay in secondes under which the equipment will not be activated",
|
||||
"minimal_activation_delay": "Minimal activation delay",
|
||||
"security_delay_min": "Security delay (in minutes)",
|
||||
"security_min_on_percent": "Minimal power percent for security mode",
|
||||
"security_default_on_percent": "Power percent to use in security mode"
|
||||
},
|
||||
"data_description": {
|
||||
"minimal_activation_delay": "Delay in seconds under which the equipment will not be activated",
|
||||
"security_delay_min": "Maximum allowed delay in minutes between two temperature mesures. Above this delay, the thermostat will turn to a security off state",
|
||||
"security_min_on_percent": "Minimal heating percent value for security preset activation. Below this amount of on_percent the thermostat won't go into security preset",
|
||||
"security_default_on_percent": "The default heating percent value in security preset. Set to 0 to switch off heater in security present"
|
||||
"security_min_on_percent": "Minimal heating percent value for security preset activation. Below this amount of power percent the thermostat won't go into security preset",
|
||||
"security_default_on_percent": "The default heating power percent value in security preset. Set to 0 to switch off heater in security present"
|
||||
}
|
||||
}
|
||||
},
|
||||
"error": {
|
||||
"unknown": "[%key:component::versatile_thermostat::config::error::unknown%]",
|
||||
"unknown_entity": "[%key:component::versatile_thermostat::config::error::unknown_entity%]",
|
||||
"window_open_detection_method": "[%key:component::versatile_thermostat::config::error::window_open_detection_method%]"
|
||||
"unknown": "Unexpected error",
|
||||
"unknown_entity": "Unknown entity id",
|
||||
"window_open_detection_method": "Only one window open detection method should be used. Use sensor or automatic detection through temperature threshold but not both"
|
||||
},
|
||||
"abort": {
|
||||
"already_configured": "[%key:component::versatile_thermostat::config::abort::already_configured%]"
|
||||
"already_configured": "Device is already configured"
|
||||
}
|
||||
},
|
||||
"selector": {
|
||||
|
||||
@@ -501,3 +501,107 @@ async def test_window_auto_auto_stop(hass: HomeAssistant, skip_hass_states_is_st
|
||||
assert entity.window_auto_state == STATE_OFF
|
||||
assert entity.hvac_mode is HVACMode.HEAT
|
||||
assert entity.preset_mode is PRESET_BOOST
|
||||
|
||||
|
||||
async def test_window_auto_no_on_percent(
|
||||
hass: HomeAssistant, skip_hass_states_is_state
|
||||
):
|
||||
"""Test the Power management"""
|
||||
|
||||
entry = MockConfigEntry(
|
||||
domain=DOMAIN,
|
||||
title="TheOverSwitchMockName",
|
||||
unique_id="uniqueId",
|
||||
data={
|
||||
CONF_NAME: "TheOverSwitchMockName",
|
||||
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_SWITCH,
|
||||
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
|
||||
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
|
||||
CONF_CYCLE_MIN: 5,
|
||||
CONF_TEMP_MIN: 15,
|
||||
CONF_TEMP_MAX: 30,
|
||||
"eco_temp": 17,
|
||||
"comfort_temp": 18,
|
||||
"boost_temp": 21,
|
||||
CONF_USE_WINDOW_FEATURE: True,
|
||||
CONF_USE_MOTION_FEATURE: False,
|
||||
CONF_USE_POWER_FEATURE: False,
|
||||
CONF_USE_PRESENCE_FEATURE: False,
|
||||
CONF_HEATER: "switch.mock_switch",
|
||||
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
|
||||
CONF_TPI_COEF_INT: 0.3,
|
||||
CONF_TPI_COEF_EXT: 0.01,
|
||||
CONF_MINIMAL_ACTIVATION_DELAY: 30,
|
||||
CONF_SECURITY_DELAY_MIN: 5,
|
||||
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
|
||||
CONF_WINDOW_AUTO_OPEN_THRESHOLD: 0.1,
|
||||
CONF_WINDOW_AUTO_CLOSE_THRESHOLD: 0.1,
|
||||
CONF_WINDOW_AUTO_MAX_DURATION: 0, # Should be 0 for test
|
||||
},
|
||||
)
|
||||
|
||||
entity: VersatileThermostat = await create_thermostat(
|
||||
hass, entry, "climate.theoverswitchmockname"
|
||||
)
|
||||
assert entity
|
||||
|
||||
tz = get_tz(hass) # pylint: disable=invalid-name
|
||||
now = datetime.now(tz)
|
||||
|
||||
tpi_algo = entity._prop_algorithm
|
||||
assert tpi_algo
|
||||
|
||||
await entity.async_set_hvac_mode(HVACMode.HEAT)
|
||||
await entity.async_set_preset_mode(PRESET_BOOST)
|
||||
assert entity.hvac_mode is HVACMode.HEAT
|
||||
assert entity.preset_mode is PRESET_BOOST
|
||||
assert entity.overpowering_state is None
|
||||
assert entity.target_temperature == 21
|
||||
|
||||
assert entity.window_state is None
|
||||
|
||||
# Make the temperature down
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat._async_heater_turn_on"
|
||||
) as mock_heater_on, patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat._async_underlying_entity_turn_off"
|
||||
) as mock_heater_off, patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat._is_device_active",
|
||||
return_value=True,
|
||||
):
|
||||
event_timestamp = now - timedelta(minutes=4)
|
||||
await send_temperature_change_event(entity, 21.5, event_timestamp)
|
||||
|
||||
# The heater turns on
|
||||
assert mock_heater_on.call_count == 0
|
||||
assert entity.last_temperature_slope is None
|
||||
assert entity._window_auto_algo.is_window_open_detected() is False
|
||||
assert entity._window_auto_algo.is_window_close_detected() is False
|
||||
assert entity.hvac_mode is HVACMode.HEAT
|
||||
assert entity.proportional_algorithm.on_percent == 0.0
|
||||
|
||||
# send one degre down in one minute
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat._async_heater_turn_on"
|
||||
) as mock_heater_on, patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat._async_underlying_entity_turn_off"
|
||||
) as mock_heater_off, patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat._is_device_active",
|
||||
return_value=True,
|
||||
):
|
||||
event_timestamp = now - timedelta(minutes=3)
|
||||
await send_temperature_change_event(entity, 20, event_timestamp)
|
||||
|
||||
# The heater turns on but no alert because the heater was not heating
|
||||
assert mock_send_event.call_count == 0
|
||||
assert mock_heater_on.call_count == 1
|
||||
assert mock_heater_off.call_count == 0
|
||||
assert entity.last_temperature_slope == -1.5
|
||||
assert entity._window_auto_algo.is_window_open_detected() is True
|
||||
assert entity._window_auto_algo.is_window_close_detected() is False
|
||||
assert entity.window_auto_state == STATE_OFF
|
||||
assert entity.hvac_mode is HVACMode.HEAT
|
||||
|
||||
@@ -59,6 +59,7 @@
|
||||
},
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "Leave empty if no window sensor should be use",
|
||||
"window_delay": "The delay in seconds before sensor detection is taken into account",
|
||||
"window_auto_open_threshold": "Recommended value: between 0.05 and 0.1. Leave empty if automatic window open detection is not use",
|
||||
"window_auto_close_threshold": "Recommended value: 0. Leave empty if automatic window open detection is not use",
|
||||
"window_auto_max_duration": "Recommended value: 60 (one hour). Leave empty if automatic window open detection is not use"
|
||||
@@ -97,10 +98,16 @@
|
||||
"title": "Advanced parameters",
|
||||
"description": "Configuration of advanced parameters. Leave the default values if you don't know what you are doing.\nThis parameters can lead to a very bad temperature or power regulation.",
|
||||
"data": {
|
||||
"minimal_activation_delay": "Delay in secondes under which the equipment will not be activated",
|
||||
"security_delay_min": "Maximum allowed delay in minutes between two temperature mesures. Above this delay, the thermostat will turn to a sceurity off state",
|
||||
"security_min_on_percent": "Minimal heating percent value for security preset activation. Below this amount of on_percent the thermostat won't go into security preset",
|
||||
"security_default_on_percent": "The default heating percent value in security preset. Set to 0 to switch off heater in security present"
|
||||
"minimal_activation_delay": "Minimal activation delay",
|
||||
"security_delay_min": "Security delay (in minutes)",
|
||||
"security_min_on_percent": "Minimal power percent for security mode",
|
||||
"security_default_on_percent": "Power percent to use in security mode"
|
||||
},
|
||||
"data_description": {
|
||||
"minimal_activation_delay": "Delay in seconds under which the equipment will not be activated",
|
||||
"security_delay_min": "Maximum allowed delay in minutes between two temperature mesures. Above this delay, the thermostat will turn to a security off state",
|
||||
"security_min_on_percent": "Minimal heating percent value for security preset activation. Below this amount of power percent the thermostat won't go into security preset",
|
||||
"security_default_on_percent": "The default heating power percent value in security preset. Set to 0 to switch off heater in security present"
|
||||
}
|
||||
}
|
||||
},
|
||||
@@ -161,20 +168,21 @@
|
||||
}
|
||||
},
|
||||
"window": {
|
||||
"title": "[%key:component::versatile_thermostat::config::step::window::title%]",
|
||||
"description": "[%key:component::versatile_thermostat::config::step::window::description%]",
|
||||
"title": "Window management",
|
||||
"description": "Open window management.\nLeave corresponding entity_id empty if not used\nYou can also configure automatic window open detection based on temperature decrease",
|
||||
"data": {
|
||||
"window_sensor_entity_id": "[%key:component::versatile_thermostat::config::step::window::data::window_sensor_entity_id%]",
|
||||
"window_delay": "[%key:component::versatile_thermostat::config::step::window::data::window_delay%]",
|
||||
"window_auto_open_threshold": "[%key:component::versatile_thermostat::config::step::window::data::window_auto_open_threshold%]",
|
||||
"window_auto_close_threshold": "[%key:component::versatile_thermostat::config::step::window::data::window_auto_close_threshold%]",
|
||||
"window_auto_max_duration": "[%key:component::versatile_thermostat::config::step::window::data::window_auto_max_duration%]"
|
||||
"window_sensor_entity_id": "Window sensor entity id",
|
||||
"window_delay": "Window sensor delay (seconds)",
|
||||
"window_auto_open_threshold": "Temperature decrease threshold for automatic window open detection (in °/min)",
|
||||
"window_auto_close_threshold": "Temperature increase threshold for end of automatic detection (in °/min)",
|
||||
"window_auto_max_duration": "Maximum duration of automatic window open detection (in min)"
|
||||
},
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "[%key:component::versatile_thermostat::config::step::window::data_description::window_sensor_entity_id%]",
|
||||
"window_auto_open_threshold": "[%key:component::versatile_thermostat::config::step::window::data_description::window_auto_open_threshold%]",
|
||||
"window_auto_close_threshold": "[%key:component::versatile_thermostat::config::step::window::data_description::window_auto_close_threshold%]",
|
||||
"window_auto_max_duration": "[%key:component::versatile_thermostat::config::step::window::data_description::window_auto_max_duration%]"
|
||||
"window_sensor_entity_id": "Leave empty if no window sensor should be use",
|
||||
"window_delay": "The delay in seconds before sensor detection is taken into account",
|
||||
"window_auto_open_threshold": "Recommended value: between 0.05 and 0.1. Leave empty if automatic window open detection is not use",
|
||||
"window_auto_close_threshold": "Recommended value: 0. Leave empty if automatic window open detection is not use",
|
||||
"window_auto_max_duration": "Recommended value: 60 (one hour). Leave empty if automatic window open detection is not use"
|
||||
}
|
||||
},
|
||||
"motion": {
|
||||
@@ -210,20 +218,26 @@
|
||||
"title": "Advanced parameters",
|
||||
"description": "Configuration of advanced parameters. Leave the default values if you don't know what you are doing.\nThis parameters can lead to a very bad temperature or power regulation.",
|
||||
"data": {
|
||||
"minimal_activation_delay": "Delay in secondes under which the equipment will not be activated",
|
||||
"minimal_activation_delay": "Minimal activation delay",
|
||||
"security_delay_min": "Security delay (in minutes)",
|
||||
"security_min_on_percent": "Minimal power percent for security mode",
|
||||
"security_default_on_percent": "Power percent to use in security mode"
|
||||
},
|
||||
"data_description": {
|
||||
"minimal_activation_delay": "Delay in seconds under which the equipment will not be activated",
|
||||
"security_delay_min": "Maximum allowed delay in minutes between two temperature mesures. Above this delay, the thermostat will turn to a security off state",
|
||||
"security_min_on_percent": "Minimal heating percent value for security preset activation. Below this amount of on_percent the thermostat won't go into security preset",
|
||||
"security_default_on_percent": "The default heating percent value in security preset. Set to 0 to switch off heater in security present"
|
||||
"security_min_on_percent": "Minimal heating percent value for security preset activation. Below this amount of power percent the thermostat won't go into security preset",
|
||||
"security_default_on_percent": "The default heating power percent value in security preset. Set to 0 to switch off heater in security present"
|
||||
}
|
||||
}
|
||||
},
|
||||
"error": {
|
||||
"unknown": "[%key:component::versatile_thermostat::config::error::unknown%]",
|
||||
"unknown_entity": "[%key:component::versatile_thermostat::config::error::unknown_entity%]",
|
||||
"window_open_detection_method": "[%key:component::versatile_thermostat::config::error::window_open_detection_method%]"
|
||||
"unknown": "Unexpected error",
|
||||
"unknown_entity": "Unknown entity id",
|
||||
"window_open_detection_method": "Only one window open detection method should be used. Use sensor or automatic detection through temperature threshold but not both"
|
||||
},
|
||||
"abort": {
|
||||
"already_configured": "[%key:component::versatile_thermostat::config::abort::already_configured%]"
|
||||
"already_configured": "Device is already configured"
|
||||
}
|
||||
},
|
||||
"selector": {
|
||||
|
||||
@@ -51,13 +51,14 @@
|
||||
"description": "Coupe le radiateur si l'ouverture est ouverte.\nLaissez l'entity id vide si non utilisé.",
|
||||
"data": {
|
||||
"window_sensor_entity_id": "Détecteur d'ouverture (entity id)",
|
||||
"window_delay": "Délai avant extinction (seconds)",
|
||||
"window_delay": "Délai avant extinction (secondes)",
|
||||
"window_auto_open_threshold": "seuil haut de chute de température pour la détection automatique (en °/min)",
|
||||
"window_auto_close_threshold": "Seuil bas de chute de température pour la fin de détection automatique (en °/min)",
|
||||
"window_auto_max_duration": "Durée maximum d'une extinction automatique (en min)"
|
||||
},
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "Laissez vide si vous n'avez de détecteur",
|
||||
"window_delay": "Le délai (en secondes) avant que le changement du détecteur soit pris en compte",
|
||||
"window_auto_open_threshold": "Valeur recommandée: entre 0.05 et 0.1. Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"window_auto_close_threshold": "Valeur recommandée: 0. Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"window_auto_max_duration": "Valeur recommandée: 60 (1 heure). Laissez vide si vous n'utilisez pas la détection automatique"
|
||||
@@ -96,8 +97,14 @@
|
||||
"title": "Parameters avancés",
|
||||
"description": "Configuration des paramètres avancés. Laissez les valeurs par défaut si vous ne savez pas ce que vous faites.\nCes paramètres peuvent induire des mauvais comportements du thermostat.",
|
||||
"data": {
|
||||
"minimal_activation_delay": "Délai en secondes en-dessous duquel l'équipement ne sera pas activé",
|
||||
"security_delay_min": "Délai maximal autorisé en minutes entre 2 mesures de températures. Au-dessus de ce délai, le thermostat se mettra en position éteinte de sécurité",
|
||||
"minimal_activation_delay": "Délai minimal d'activation",
|
||||
"security_delay_min": "Délai maximal entre 2 mesures de températures",
|
||||
"security_min_on_percent": "Pourcentage minimal de puissance",
|
||||
"security_default_on_percent": "Pourcentage de puissance a utiliser en mode securité"
|
||||
},
|
||||
"data_description": {
|
||||
"minimal_activation_delay": "Délai en seondes en-dessous duquel l'équipement ne sera pas activé",
|
||||
"security_delay_min": "Délai maximal autorisé en minutes entre 2 mesures de températures. Au-dessus de ce délai, le thermostat se mettra en position de sécurité",
|
||||
"security_min_on_percent": "Seuil minimal de pourcentage de chauffage en-dessous duquel le préréglage sécurité ne sera jamais activé",
|
||||
"security_default_on_percent": "Valeur par défaut pour le pourcentage de chauffage en mode sécurité. Mettre 0 pour éteindre le radiateur en mode sécurité"
|
||||
}
|
||||
@@ -161,20 +168,21 @@
|
||||
}
|
||||
},
|
||||
"window": {
|
||||
"title": "[%key:component::versatile_thermostat::config::step::window::title%]",
|
||||
"description": "[%key:component::versatile_thermostat::config::step::window::description%]",
|
||||
"title": "Gestion d'une ouverture",
|
||||
"description": "Coupe le radiateur si l'ouverture est ouverte.\nLaissez l'entity id vide si non utilisé.",
|
||||
"data": {
|
||||
"window_sensor_entity_id": "[%key:component::versatile_thermostat::config::step::window::data::window_sensor_entity_id%]",
|
||||
"window_delay": "[%key:component::versatile_thermostat::config::step::window::data::window_delay%]",
|
||||
"window_auto_open_threshold": "[%key:component::versatile_thermostat::config::step::window::data::window_auto_open_threshold%]",
|
||||
"window_auto_close_threshold": "[%key:component::versatile_thermostat::config::step::window::data::window_auto_close_threshold%]",
|
||||
"window_auto_max_duration": "[%key:component::versatile_thermostat::config::step::window::data::window_auto_max_duration%]"
|
||||
"window_sensor_entity_id": "Détecteur d'ouverture (entity id)",
|
||||
"window_delay": "Délai avant extinction (secondes)",
|
||||
"window_auto_open_threshold": "seuil haut de chute de température pour la détection automatique (en °/min)",
|
||||
"window_auto_close_threshold": "Seuil bas de chute de température pour la fin de détection automatique (en °/min)",
|
||||
"window_auto_max_duration": "Durée maximum d'une extinction automatique (en min)"
|
||||
},
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "[%key:component::versatile_thermostat::config::step::window::data_description::window_sensor_entity_id%]",
|
||||
"window_auto_open_threshold": "[%key:component::versatile_thermostat::config::step::window::data_description::window_auto_open_threshold%]",
|
||||
"window_auto_close_threshold": "[%key:component::versatile_thermostat::config::step::window::data_description::window_auto_close_threshold%]",
|
||||
"window_auto_max_duration": "[%key:component::versatile_thermostat::config::step::window::data_description::window_auto_max_duration%]"
|
||||
"window_sensor_entity_id": "Laissez vide si vous n'avez de détecteur",
|
||||
"window_delay": "Le délai (en secondes) avant que le changement du détecteur soit pris en compte",
|
||||
"window_auto_open_threshold": "Valeur recommandée: entre 0.05 et 0.1. Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"window_auto_close_threshold": "Valeur recommandée: 0. Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"window_auto_max_duration": "Valeur recommandée: 60 (1 heure). Laissez vide si vous n'utilisez pas la détection automatique"
|
||||
}
|
||||
},
|
||||
"motion": {
|
||||
@@ -210,20 +218,26 @@
|
||||
"title": "Parameters avancés",
|
||||
"description": "Configuration des paramètres avancés. Laissez les valeurs par défaut si vous ne savez pas ce que vous faites.\nCes paramètres peuvent induire des mauvais comportements du thermostat.",
|
||||
"data": {
|
||||
"minimal_activation_delay": "Délai minimal d'activation",
|
||||
"security_delay_min": "Délai maximal entre 2 mesures de températures",
|
||||
"security_min_on_percent": "Pourcentage minimal de puissance",
|
||||
"security_default_on_percent": "Pourcentage de puissance a utiliser en mode securité"
|
||||
},
|
||||
"data_description": {
|
||||
"minimal_activation_delay": "Délai en seondes en-dessous duquel l'équipement ne sera pas activé",
|
||||
"security_delay_min": "Délai maximal autorisé en minutes entre 2 mesures de températures. Au-dessus de ce délai, le thermostat se mettra en position éteinte de sécurité",
|
||||
"security_delay_min": "Délai maximal autorisé en minutes entre 2 mesures de températures. Au-dessus de ce délai, le thermostat se mettra en position de sécurité",
|
||||
"security_min_on_percent": "Seuil minimal de pourcentage de chauffage en-dessous duquel le préréglage sécurité ne sera jamais activé",
|
||||
"security_default_on_percent": "Valeur par défaut pour le pourcentage de chauffage en mode sécurité. Mettre 0 pour éteindre le radiateur en mode sécurité"
|
||||
}
|
||||
}
|
||||
},
|
||||
"error": {
|
||||
"unknown": "[%key:component::versatile_thermostat::config::error::unknown%]",
|
||||
"unknown_entity": "[%key:component::versatile_thermostat::config::error::unknown_entity%]",
|
||||
"window_open_detection_method": "[%key:component::versatile_thermostat::config::error::window_open_detection_method%]"
|
||||
"unknown": "Erreur inattendue",
|
||||
"unknown_entity": "entity id inconnu",
|
||||
"window_open_detection_method": "Une seule méthode de détection des ouvertures ouvertes doit être utilisée. Utilisez le détecteur d'ouverture ou les seuils de température mais pas les deux."
|
||||
},
|
||||
"abort": {
|
||||
"already_configured": "[%key:component::versatile_thermostat::config::abort::already_configured%]"
|
||||
"already_configured": "Le device est déjà configuré"
|
||||
}
|
||||
},
|
||||
"selector": {
|
||||
|
||||
Reference in New Issue
Block a user