# Camera-Specific Integration Tests
|
|
|
|
This directory contains integration tests for specific ONVIF camera models based on real-world testing.
|
|
|
|
## Bosch FLEXIDOME indoor 5100i IR Tests
|
|
|
|
The `bosch_flexidome_test.go` file contains comprehensive tests verified against a real Bosch FLEXIDOME indoor 5100i IR camera running firmware 8.71.0066.
|
|
|
|
### Running the Tests
|
|
|
|
Set the following environment variables with your camera credentials:
|
|
|
|
```bash
|
|
export ONVIF_TEST_ENDPOINT="http://192.168.1.201/onvif/device_service"
|
|
export ONVIF_TEST_USERNAME="service"
|
|
export ONVIF_TEST_PASSWORD="Service.1234"
|
|
```
|
|
|
|
Then run the tests:
|
|
|
|
```bash
|
|
# Run all tests
|
|
go test -v ./... -run TestBoschFLEXIDOMEIndoor5100iIR
|
|
|
|
# Run specific test
|
|
go test -v -run TestBoschFLEXIDOMEIndoor5100iIR_GetDeviceInformation
|
|
|
|
# Run all tests with race detection
|
|
go test -v -race -run TestBoschFLEXIDOMEIndoor5100iIR
|
|
|
|
# Run benchmarks
|
|
go test -v -bench=BenchmarkBoschFLEXIDOMEIndoor5100iIR -benchmem
|
|
|
|
# Run full workflow test
|
|
go test -v -run TestBoschFLEXIDOMEIndoor5100iIR_FullWorkflow
|
|
```
|
|
|
|
### Test Coverage
|
|
|
|
The tests cover the following ONVIF operations:
|
|
|
|
- ✅ **GetDeviceInformation** - Device identification and firmware info
|
|
- ✅ **GetSystemDateAndTime** - System time retrieval
|
|
- ✅ **GetCapabilities** - Service capability discovery
|
|
- ✅ **Initialize** - Service endpoint initialization
|
|
- ✅ **GetProfiles** - Media profile retrieval (4 profiles expected)
|
|
- ✅ **GetStreamURI** - RTSP stream URI retrieval for all profiles
|
|
- ✅ **GetSnapshotURI** - Snapshot URI retrieval
|
|
- ✅ **GetVideoEncoderConfiguration** - Video encoder settings
|
|
- ✅ **GetImagingSettings** - Camera imaging parameters
|
|
- ✅ **Full Workflow** - Complete operation sequence
|
|
|
|
### Expected Results for Bosch FLEXIDOME indoor 5100i IR
|
|
|
|
- **Manufacturer**: Bosch
|
|
- **Model**: FLEXIDOME indoor 5100i IR
|
|
- **Profiles**: 4 H264 profiles
|
|
- Profile 1: 1920x1080 @ 30fps, 5200 kbps
|
|
- Profile 2: 1536x864
|
|
- Profile 3: 1280x720
|
|
- Profile 4: 512x288
|
|
- **Services**: Device, Media, Imaging, Events, Analytics
|
|
- **Stream Protocol**: RTSP
|
|
- **Snapshot Format**: JPEG
|
|
- **Default Imaging Settings**:
|
|
- Brightness: 128.0
|
|
- Color Saturation: 128.0
|
|
- Contrast: 128.0
|
|
|
|
### Test Without Camera
|
|
|
|
If environment variables are not set, tests will be automatically skipped:
|
|
|
|
```bash
|
|
go test -v ./...
|
|
# Output: SKIP: Skipping test: ONVIF camera credentials not set
|
|
```
|
|
|
|
### Performance Benchmarks
|
|
|
|
The test suite includes benchmarks for critical operations:
|
|
|
|
- `BenchmarkBoschFLEXIDOMEIndoor5100iIR_GetDeviceInformation` - Device info retrieval performance
|
|
- `BenchmarkBoschFLEXIDOMEIndoor5100iIR_GetStreamURI` - Stream URI retrieval performance
|
|
|
|
### Adding Tests for Other Camera Models
|
|
|
|
To add tests for a new camera model:
|
|
|
|
1. Create a new test file: `<manufacturer>_<model>_test.go`
|
|
2. Follow the same pattern as `bosch_flexidome_test.go`
|
|
3. Update environment variable names to be model-specific if needed
|
|
4. Document expected values and behaviors for the specific model
|
|
5. Add README entry with camera-specific details
|
|
|
|
Example:
|
|
```go
|
|
// hikvision_ds2cd2xxx_test.go
|
|
func TestHikvisionDS2CD_GetDeviceInformation(t *testing.T) {
|
|
// Test implementation
|
|
}
|
|
```
|
|
|
|
### Continuous Integration
|
|
|
|
These tests can be integrated into CI/CD pipelines using secrets management:
|
|
|
|
```yaml
|
|
# GitHub Actions example
|
|
- name: Run Camera Integration Tests
|
|
env:
|
|
ONVIF_TEST_ENDPOINT: ${{ secrets.ONVIF_ENDPOINT }}
|
|
ONVIF_TEST_USERNAME: ${{ secrets.ONVIF_USERNAME }}
|
|
ONVIF_TEST_PASSWORD: ${{ secrets.ONVIF_PASSWORD }}
|
|
run: go test -v -run TestBoschFLEXIDOMEIndoor5100iIR
|
|
```
|
|
|
|
### Troubleshooting
|
|
|
|
**Tests fail with "connection refused":**
|
|
- Verify camera IP address and network connectivity
|
|
- Check firewall settings
|
|
- Ensure camera is powered on
|
|
|
|
**Tests fail with authentication errors:**
|
|
- Verify username and password are correct
|
|
- Check if camera requires digest authentication
|
|
- Ensure user has appropriate permissions
|
|
|
|
**Tests fail with unexpected values:**
|
|
- Camera firmware may have been updated
|
|
- Camera settings may have been changed
|
|
- Update expected values in tests to match current configuration
|
|
|
|
### Notes
|
|
|
|
- These tests require a physical camera or camera simulator
|
|
- Tests modify NO camera settings (read-only operations)
|
|
- Some tests may take several seconds due to network communication
|
|
- Camera responses may vary based on firmware version and configuration
|