""" Test the Power management """
from unittest.mock import patch, call
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
from datetime import datetime, timedelta
from homeassistant.const import UnitOfTemperature
import logging
logging.getLogger().setLevel(logging.DEBUG)
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_power_management_hvac_off(
hass: HomeAssistant, skip_hass_states_is_state
):
"""Test the Power management"""
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverSwitchMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverSwitchMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_SWITCH,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 19,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: True,
CONF_USE_PRESENCE_FEATURE: False,
CONF_HEATER: "switch.mock_switch",
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_POWER_SENSOR: "sensor.mock_power_sensor",
CONF_MAX_POWER_SENSOR: "sensor.mock_power_max_sensor",
CONF_DEVICE_POWER: 100,
CONF_PRESET_POWER: 12,
},
)
entity: VersatileThermostat = await create_thermostat(
hass, entry, "climate.theoverswitchmockname"
)
assert entity
tpi_algo = entity._prop_algorithm
assert tpi_algo
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 19
assert entity.overpowering_state is None
assert entity.hvac_mode == HVACMode.OFF
# Send power mesurement
await send_power_change_event(entity, 50, datetime.now())
assert await entity.check_overpowering() is False
# All configuration is not complete
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
# Send power max mesurement
await send_max_power_change_event(entity, 300, datetime.now())
assert await entity.check_overpowering() is False
# All configuration is complete and power is < power_max
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is False
# Send power max mesurement too low but HVACMode is off
with patch(
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off:
await send_max_power_change_event(entity, 149, datetime.now())
assert await entity.check_overpowering() is True
# All configuration is complete and power is > power_max but we stay in Boost cause thermostat if Off
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is True
assert mock_send_event.call_count == 0
assert mock_heater_on.call_count == 0
assert mock_heater_off.call_count == 0
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_power_management_hvac_on(hass: HomeAssistant, skip_hass_states_is_state):
"""Test the Power management"""
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverSwitchMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverSwitchMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_SWITCH,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 19,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: True,
CONF_USE_PRESENCE_FEATURE: False,
CONF_HEATER: "switch.mock_switch",
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_POWER_SENSOR: "sensor.mock_power_sensor",
CONF_MAX_POWER_SENSOR: "sensor.mock_power_max_sensor",
CONF_DEVICE_POWER: 100,
CONF_PRESET_POWER: 12,
},
)
entity: VersatileThermostat = await create_thermostat(
hass, entry, "climate.theoverswitchmockname"
)
assert entity
tpi_algo = entity._prop_algorithm
assert tpi_algo
await entity.async_set_hvac_mode(HVACMode.HEAT)
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is None
assert entity.target_temperature == 19
# Send power mesurement
await send_power_change_event(entity, 50, datetime.now())
# Send power max mesurement
await send_max_power_change_event(entity, 300, datetime.now())
assert await entity.check_overpowering() is False
# All configuration is complete and power is < power_max
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is False
# Send power max mesurement too low and HVACMode is on
with patch(
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off:
await send_max_power_change_event(entity, 149, datetime.now())
assert await entity.check_overpowering() is True
# All configuration is complete and power is > power_max we switch to POWER preset
assert entity.preset_mode is PRESET_POWER
assert entity.overpowering_state is True
assert entity.target_temperature == 12
assert mock_send_event.call_count == 2
mock_send_event.assert_has_calls(
[
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_POWER}),
call.send_event(
EventType.POWER_EVENT,
{
"type": "start",
"current_power": 50,
"device_power": 100,
"current_power_max": 149,
},
),
],
any_order=True,
)
assert mock_heater_on.call_count == 0
assert mock_heater_off.call_count == 1
# Send power mesurement low to unseet power preset
with patch(
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off:
await send_power_change_event(entity, 48, datetime.now())
assert await entity.check_overpowering() is False
# All configuration is complete and power is < power_max, we restore previous preset
assert entity.preset_mode is PRESET_BOOST
assert entity.overpowering_state is False
assert entity.target_temperature == 19
assert mock_send_event.call_count == 2
mock_send_event.assert_has_calls(
[
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_BOOST}),
call.send_event(
EventType.POWER_EVENT,
{
"type": "end",
"current_power": 48,
"device_power": 100,
"current_power_max": 149,
},
),
],
any_order=True,
)
# No current temperature is set so the heater wont be turned on
assert mock_heater_on.call_count == 0
assert mock_heater_off.call_count == 0
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_power_management_energy_over_switch(
hass: HomeAssistant, skip_hass_states_is_state
):
"""Test the Power management energy mesurement"""
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverSwitchMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverSwitchMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_SWITCH,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 19,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: True,
CONF_USE_PRESENCE_FEATURE: False,
CONF_HEATER: "switch.mock_switch",
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_POWER_SENSOR: "sensor.mock_power_sensor",
CONF_MAX_POWER_SENSOR: "sensor.mock_power_max_sensor",
CONF_DEVICE_POWER: 100,
CONF_PRESET_POWER: 12,
},
)
entity: VersatileThermostat = await create_thermostat(
hass, entry, "climate.theoverswitchmockname"
)
assert entity
tpi_algo = entity._prop_algorithm
assert tpi_algo
assert entity.total_energy == 0
# set temperature to 15 so that on_percent will be set
with patch(
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off:
await entity.async_set_hvac_mode(HVACMode.HEAT)
await entity.async_set_preset_mode(PRESET_BOOST)
await send_temperature_change_event(entity, 15, datetime.now())
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 19
assert entity.current_temperature == 15
assert tpi_algo.on_percent == 1
assert entity.mean_cycle_power == 100.0
assert mock_send_event.call_count == 2
assert mock_heater_on.call_count == 1
assert mock_heater_off.call_count == 0
entity.incremente_energy()
assert entity.total_energy == 100 * 5 / 60.0
entity.incremente_energy()
assert entity.total_energy == 2 * 100 * 5 / 60.0
# change temperature to a higher value
with patch(
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off:
await send_temperature_change_event(entity, 18, datetime.now())
assert tpi_algo.on_percent == 0.3
assert entity.mean_cycle_power == 30.0
assert mock_send_event.call_count == 0
assert mock_heater_on.call_count == 0
assert mock_heater_off.call_count == 0
entity.incremente_energy()
assert round(entity.total_energy, 2) == round((2.0 + 0.3) * 100 * 5 / 60.0, 2)
entity.incremente_energy()
assert round(entity.total_energy, 2) == round((2.0 + 0.6) * 100 * 5 / 60.0, 2)
# change temperature to a much higher value so that heater will be shut down
with patch(
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off:
await send_temperature_change_event(entity, 20, datetime.now())
assert tpi_algo.on_percent == 0.0
assert entity.mean_cycle_power == 0.0
assert mock_send_event.call_count == 0
assert mock_heater_on.call_count == 0
assert mock_heater_off.call_count == 0
entity.incremente_energy()
# No change on energy
assert round(entity.total_energy, 2) == round((2.0 + 0.6) * 100 * 5 / 60.0, 2)
# Still no change
entity.incremente_energy()
assert round(entity.total_energy, 2) == round((2.0 + 0.6) * 100 * 5 / 60.0, 2)
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_power_management_energy_over_climate(
hass: HomeAssistant, skip_hass_states_is_state
):
"""Test the Power management for a over_climate thermostat"""
the_mock_underlying = MagicMockClimate()
with patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=the_mock_underlying,
):
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverClimateMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 19,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: True,
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_POWER_SENSOR: "sensor.mock_power_sensor",
CONF_MAX_POWER_SENSOR: "sensor.mock_power_max_sensor",
CONF_DEVICE_POWER: 100,
CONF_PRESET_POWER: 12,
},
)
entity: VersatileThermostat = await create_thermostat(
hass, entry, "climate.theoverclimatemockname"
)
assert entity
assert entity.is_over_climate
now = datetime.now(tz=get_tz(hass))
await send_temperature_change_event(entity, 15, now)
await entity.async_set_hvac_mode(HVACMode.HEAT)
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.hvac_action is HVACAction.IDLE
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 19
assert entity.current_temperature == 15
# Not initialised yet
assert entity.mean_cycle_power is None
assert entity._underlying_climate_start_hvac_action_date is None
# Send a climate_change event with HVACAction=HEATING
event_timestamp = now - timedelta(minutes=3)
await send_climate_change_event(
entity,
new_hvac_mode=HVACMode.HEAT,
old_hvac_mode=HVACMode.HEAT,
new_hvac_action=HVACAction.HEATING,
old_hvac_action=HVACAction.OFF,
date=event_timestamp,
)
# We have the start event and not the end event
assert (entity._underlying_climate_start_hvac_action_date - now).total_seconds() < 1
entity.incremente_energy()
assert entity.total_energy == 0
# Send a climate_change event with HVACAction=IDLE (end of heating)
await send_climate_change_event(
entity,
new_hvac_mode=HVACMode.HEAT,
old_hvac_mode=HVACMode.HEAT,
new_hvac_action=HVACAction.IDLE,
old_hvac_action=HVACAction.HEATING,
date=now,
)
# We have the end event -> we should have some power and on_percent
assert entity._underlying_climate_start_hvac_action_date is None
# 3 minutes at 100 W
assert entity.total_energy == 100 * 3.0 / 60
# Test the re-increment
entity.incremente_energy()