# pylint: disable=line-too-long, disable=protected-access
""" Test the normal start of a Switch AC Thermostat """
from unittest.mock import patch, call
from datetime import datetime, timedelta
from homeassistant.core import HomeAssistant, State
from homeassistant.components.climate import HVACAction, HVACMode
from homeassistant.config_entries import ConfigEntryState
from homeassistant.helpers.entity_component import EntityComponent
from homeassistant.components.climate import ClimateEntity, DOMAIN as CLIMATE_DOMAIN
from pytest_homeassistant_custom_component.common import MockConfigEntry
from custom_components.versatile_thermostat.thermostat_valve import ThermostatOverValve
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_over_valve_full_start(
hass: HomeAssistant, skip_hass_states_is_state
): # pylint: disable=unused-argument
"""Test the normal full start of a thermostat in thermostat_over_switch type"""
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverValveMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverValveMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_VALVE,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_VALVE: "number.mock_valve",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
PRESET_FROST_PROTECTION + PRESET_TEMP_SUFFIX: 7,
PRESET_ECO + PRESET_TEMP_SUFFIX: 17,
PRESET_COMFORT + PRESET_TEMP_SUFFIX: 19,
PRESET_BOOST + PRESET_TEMP_SUFFIX: 21,
CONF_USE_WINDOW_FEATURE: True,
CONF_USE_MOTION_FEATURE: True,
CONF_USE_POWER_FEATURE: True,
CONF_USE_PRESENCE_FEATURE: True,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MOTION_SENSOR: "input_boolean.motion_sensor",
CONF_WINDOW_SENSOR: "binary_sensor.window_sensor",
CONF_WINDOW_DELAY: 10,
CONF_MOTION_DELAY: 10,
CONF_MOTION_OFF_DELAY: 30,
CONF_MOTION_PRESET: PRESET_COMFORT,
CONF_NO_MOTION_PRESET: PRESET_ECO,
CONF_POWER_SENSOR: "sensor.power_sensor",
CONF_MAX_POWER_SENSOR: "sensor.power_max_sensor",
CONF_PRESENCE_SENSOR: "person.presence_sensor",
PRESET_FROST_PROTECTION + PRESET_AWAY_SUFFIX + PRESET_TEMP_SUFFIX: 7,
PRESET_ECO + PRESET_AWAY_SUFFIX + PRESET_TEMP_SUFFIX: 17.1,
PRESET_COMFORT + PRESET_AWAY_SUFFIX + PRESET_TEMP_SUFFIX: 17.2,
PRESET_BOOST + PRESET_AWAY_SUFFIX + PRESET_TEMP_SUFFIX: 17.3,
CONF_PRESET_POWER: 10,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_DEVICE_POWER: 100,
CONF_AC_MODE: False,
},
)
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
# 1. create the entity
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event:
entity = await create_thermostat(hass, entry, "climate.theovervalvemockname")
assert entity
assert isinstance(entity, ThermostatOverValve)
assert entity.name == "TheOverValveMockName"
assert entity.is_over_climate is False
assert entity.is_over_switch is False
assert entity.is_over_valve is True
assert entity.ac_mode is False
assert entity.hvac_mode is HVACMode.OFF
assert entity.hvac_action is HVACAction.OFF
assert entity.hvac_modes == [HVACMode.HEAT, HVACMode.OFF]
assert entity.target_temperature == entity.min_temp
assert entity.preset_modes == [
PRESET_NONE,
PRESET_FROST_PROTECTION,
PRESET_ECO,
PRESET_COMFORT,
PRESET_BOOST,
PRESET_ACTIVITY,
]
assert entity.preset_mode is PRESET_NONE
assert entity._security_state is False # pylint: disable=protected-access
assert entity._window_state is None # pylint: disable=protected-access
assert entity._motion_state is None # pylint: disable=protected-access
assert entity._presence_state is None # pylint: disable=protected-access
assert entity._prop_algorithm is not None # pylint: disable=protected-access
# should have been called with EventType.PRESET_EVENT and EventType.HVAC_MODE_EVENT
# assert mock_send_event.call_count == 2
mock_send_event.assert_has_calls(
[
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_NONE}),
call.send_event(
EventType.HVAC_MODE_EVENT,
{"hvac_mode": HVACMode.OFF},
),
]
)
# 2. Set the HVACMode to HEAT, with manual preset and target_temp to 18 before receiving temperature
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event:
# Select a hvacmode, presence and preset
await entity.async_set_hvac_mode(HVACMode.HEAT)
#
assert entity.hvac_mode is HVACMode.HEAT
# No heating now
assert entity.valve_open_percent == 0
assert entity.hvac_action == HVACAction.IDLE
assert mock_send_event.call_count == 1
mock_send_event.assert_has_calls(
[
call.send_event(
EventType.HVAC_MODE_EVENT,
{"hvac_mode": HVACMode.HEAT},
),
]
)
# set manual target temp
await entity.async_set_temperature(temperature=18)
assert entity.preset_mode == PRESET_NONE # Manual mode
assert entity.target_temperature == 18
# Nothing have changed cause we don't have room and external temperature
assert mock_send_event.call_count == 1
# 3. Set temperature and external temperature
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"homeassistant.core.ServiceRegistry.async_call"
) as mock_service_call, patch(
"homeassistant.core.StateMachine.get",
return_value=State(entity_id="number.mock_valve", state="90"),
):
# Change temperature
event_timestamp = now - timedelta(minutes=10)
await send_temperature_change_event(entity, 15, datetime.now())
assert entity.valve_open_percent == 90
await send_ext_temperature_change_event(entity, 10, datetime.now())
# Should heating strongly now
assert entity.valve_open_percent == 98
assert entity.is_device_active is True
assert entity.hvac_action == HVACAction.HEATING
assert mock_service_call.call_count == 2
mock_service_call.assert_has_calls(
[
call.async_call(
domain="number",
service="set_value",
service_data={"value": 90},
target={"entity_id": "number.mock_valve"},
# {"entity_id": "number.mock_valve", "value": 90},
),
call.async_call(
domain="number",
service="set_value",
service_data={"value": 98},
target={"entity_id": "number.mock_valve"},
# {"entity_id": "number.mock_valve", "value": 98},
),
]
)
assert mock_send_event.call_count == 0
# Change to preset Comfort
# Change presence to off
event_timestamp = now - timedelta(minutes=4)
await send_presence_change_event(entity, False, True, event_timestamp)
await entity.async_set_preset_mode(preset_mode=PRESET_COMFORT)
assert entity.preset_mode == PRESET_COMFORT
assert entity.target_temperature == 17.2 # Comfort with presence off
assert entity.valve_open_percent == 73
assert entity.is_device_active is True
assert entity.hvac_action == HVACAction.HEATING
# Change presence to on
event_timestamp = now - timedelta(minutes=3)
await send_presence_change_event(entity, True, False, event_timestamp)
assert entity.presence_state == STATE_ON # pylint: disable=protected-access
assert entity.preset_mode is PRESET_COMFORT
assert entity.target_temperature == 19
assert entity.valve_open_percent == 100 # Full heating
assert entity.is_device_active is True
assert entity.hvac_action == HVACAction.HEATING
# 4. Change internal temperature
expected_state = State(
entity_id="number.mock_valve", state="0", attributes={"min": 10, "max": 50}
)
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"homeassistant.core.ServiceRegistry.async_call"
) as mock_service_call, patch(
"homeassistant.core.StateMachine.get", return_value=expected_state
):
event_timestamp = now - timedelta(minutes=2)
await send_temperature_change_event(entity, 20, datetime.now())
assert entity.valve_open_percent == 0
assert entity.is_device_active is True # Should be 0 but in fact 10 is send
assert (
entity.hvac_action == HVACAction.HEATING
) # Should be IDLE but heating due to 10
assert mock_service_call.call_count == 1
# The VTherm valve is 0, but the underlying have received 10 which is the min
mock_service_call.assert_has_calls(
[
call.async_call(
domain="number",
service="set_value",
service_data={"value": 10},
target={"entity_id": "number.mock_valve"},
)
]
)
await send_temperature_change_event(entity, 17, datetime.now())
assert mock_service_call.call_count == 2
# The VTherm valve is 0, but the underlying have received 10 which is the min
mock_service_call.assert_has_calls(
[
call.async_call(
domain="number",
service="set_value",
service_data={"value": 10},
target={"entity_id": "number.mock_valve"}, # the min allowed value
),
call.async_call(
domain="number",
service="set_value",
service_data={
"value": 34
}, # 34 is 50 x open_percent (69%) and is the max allowed value
target={"entity_id": "number.mock_valve"},
),
]
)
# switch to Eco
await entity.async_set_preset_mode(PRESET_ECO)
assert entity.preset_mode is PRESET_ECO
assert entity.target_temperature == 17
assert entity.valve_open_percent == 7
# Unset the presence
event_timestamp = now - timedelta(minutes=1)
await send_presence_change_event(entity, False, True, event_timestamp)
assert entity.presence_state == STATE_OFF # pylint: disable=protected-access
assert entity.valve_open_percent == 10
assert entity.target_temperature == 17.1 # eco_away
assert entity.is_device_active is True
assert entity.hvac_action == HVACAction.HEATING
# 5. Test window open/close (with a normal min/max so that is_device_active is False when open_percent is 0)
expected_state = State(
entity_id="number.mock_valve", state="0", attributes={"min": 0, "max": 255}
)
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"homeassistant.core.ServiceRegistry.async_call"
) as mock_service_call, patch(
"homeassistant.core.StateMachine.get", return_value=expected_state
):
# Open a window
with patch("homeassistant.helpers.condition.state", return_value=True):
event_timestamp = now - timedelta(minutes=1)
try_condition = await send_window_change_event(
entity, True, False, event_timestamp
)
# Confirme the window event
await try_condition(None)
assert entity.hvac_mode is HVACMode.OFF
assert entity.hvac_action is HVACAction.OFF
assert entity.target_temperature == 17.1 # eco
assert entity.valve_open_percent == 0
# Close a window
with patch("homeassistant.helpers.condition.state", return_value=True):
event_timestamp = now - timedelta(minutes=0)
try_condition = await send_window_change_event(
entity, False, True, event_timestamp
)
# Confirme the window event
await try_condition(None)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.hvac_action is HVACAction.HEATING
assert entity.target_temperature == 17.1 # eco
assert entity.valve_open_percent == 10
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_over_valve_regulation(
hass: HomeAssistant, skip_hass_states_is_state
): # pylint: disable=unused-argument
"""Test the normal full start of a thermostat in thermostat_over_switch type"""
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverValveMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverValveMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_VALVE,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_VALVE: "number.mock_valve",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
PRESET_FROST_PROTECTION + PRESET_TEMP_SUFFIX: 7,
PRESET_ECO + PRESET_TEMP_SUFFIX: 17,
PRESET_COMFORT + PRESET_TEMP_SUFFIX: 19,
PRESET_BOOST + PRESET_TEMP_SUFFIX: 21,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 60,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
# only send new valve open percent if dtemp is > 30%
CONF_AUTO_REGULATION_DTEMP: 5,
# only send new valve open percent last mesure was more than 5 min ago
CONF_AUTO_REGULATION_PERIOD_MIN: 5,
},
)
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
# 1. prepare the Valve at now
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event:
entity: ThermostatOverValve = await create_thermostat(
hass, entry, "climate.theovervalvemockname"
)
assert entity
assert isinstance(entity, ThermostatOverValve)
assert entity.name == "TheOverValveMockName"
assert entity.is_over_valve is True
assert entity._auto_regulation_dpercent == 5
assert entity._auto_regulation_period_min == 5
assert entity.target_temperature == entity.min_temp
assert entity._prop_algorithm is not None
# 2. Set the HVACMode to HEAT, with manual preset and target_temp to 18 before receiving temperature
# at now +1
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event:
now = now + timedelta(minutes=1)
entity._set_now(now)
# Select a hvacmode, presence and preset
await entity.async_set_hvac_mode(HVACMode.HEAT)
assert entity.hvac_mode is HVACMode.HEAT
# No heating now
assert entity.valve_open_percent == 0
assert entity.hvac_action == HVACAction.IDLE
assert mock_send_event.call_count == 1
mock_send_event.assert_has_calls(
[
call.send_event(
EventType.HVAC_MODE_EVENT,
{"hvac_mode": HVACMode.HEAT},
),
]
)
# 3. Set the preset
# at now +1
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event:
now = now + timedelta(minutes=1)
entity._set_now(now)
# set preset
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.preset_mode == PRESET_BOOST
assert entity.target_temperature == 21
# the preset have changed
assert mock_send_event.call_count == 1
mock_send_event.assert_has_calls(
[
call.send_event(
EventType.PRESET_EVENT,
{"preset": PRESET_BOOST},
),
]
)
await entity.async_set_hvac_mode(HVACMode.HEAT)
assert entity.hvac_mode is HVACMode.HEAT
# Still no heating because we don't have temperature
assert entity.valve_open_percent == 0
assert entity.hvac_action == HVACAction.IDLE
# 4. Set temperature and external temperature
# at now + 1 (but the _last_calculation_timestamp is still not send)
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"homeassistant.core.ServiceRegistry.async_call"
) as mock_service_call, patch(
"homeassistant.core.StateMachine.get",
return_value=State(entity_id="number.mock_valve", state="90"),
):
# Change temperature
now = now + timedelta(minutes=1)
entity._set_now(now)
await send_temperature_change_event(entity, 18, now)
assert entity.valve_open_percent == 90
assert entity.is_device_active is True
assert entity.hvac_action == HVACAction.HEATING
assert mock_service_call.call_count == 1
mock_service_call.assert_has_calls(
[
call.async_call(
domain="number",
service="set_value",
service_data={"value": 90},
target={"entity_id": "number.mock_valve"},
),
]
)
assert mock_send_event.call_count == 0
# 5. Set external temperature
# at now + 1
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"homeassistant.core.ServiceRegistry.async_call"
) as mock_service_call, patch(
"homeassistant.core.StateMachine.get",
return_value=State(entity_id="number.mock_valve", state="90"),
):
# Change external temperature
now = now + timedelta(minutes=1)
entity._set_now(now)
await send_ext_temperature_change_event(entity, 10, now)
# Should not have change due to regulation (period_min !)
assert entity.valve_open_percent == 90
assert entity.is_device_active is True
assert entity.hvac_action == HVACAction.HEATING
assert mock_service_call.call_count == 0
assert mock_send_event.call_count == 0
# 6. Set temperature
# at now + 5 (to avoid the period_min threshold)
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"homeassistant.core.ServiceRegistry.async_call"
) as mock_service_call, patch(
"homeassistant.core.StateMachine.get",
return_value=State(entity_id="number.mock_valve", state="90"),
):
# Change external temperature
now = now + timedelta(minutes=5)
entity._set_now(now)
await send_ext_temperature_change_event(entity, 15, now)
# Should have change this time to 96
assert entity.valve_open_percent == 96
assert entity.is_device_active is True
assert entity.hvac_action == HVACAction.HEATING
assert mock_service_call.call_count == 1
mock_service_call.assert_has_calls(
[
call.async_call(
domain="number",
service="set_value",
service_data={"value": 96},
target={"entity_id": "number.mock_valve"},
),
]
)
assert mock_send_event.call_count == 0
# 7. Set small temperature update to test dtemp threshold
# at now + 5
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"homeassistant.core.ServiceRegistry.async_call"
) as mock_service_call, patch(
"homeassistant.core.StateMachine.get",
return_value=State(entity_id="number.mock_valve", state="96"),
):
# Change external temperature
now = now + timedelta(minutes=5)
entity._set_now(now)
# this generate a delta percent of -3
await send_temperature_change_event(entity, 18.1, now)
# Should not have due to dtemp
assert entity.valve_open_percent == 96
assert entity.is_device_active is True
assert entity.hvac_action == HVACAction.HEATING
assert mock_service_call.call_count == 0
assert mock_send_event.call_count == 0