default_config:
recorder:
auto_purge: true
purge_keep_days: 1
commit_interval: 5
include:
domains:
- input_boolean
- input_number
- input_select
- switch
- climate
- sensor
- binary_sensor
- number
- select
- versatile_thermostat
logger:
default: warning
logs:
custom_components.versatile_thermostat: debug
# custom_components.versatile_thermostat.underlyings: info
# custom_components.versatile_thermostat.climate: info
# custom_components.versatile_thermostat.base_thermostat: debug
custom_components.versatile_thermostat.sensor: info
custom_components.versatile_thermostat.binary_sensor: info
# If you need to debug uncommment the line below (doc: https://www.home-assistant.io/integrations/debugpy/)
debugpy:
start: true
wait: false
port: 5678
versatile_thermostat:
auto_regulation_expert:
kp: 0.4
ki: 0.08
k_ext: 0.0
offset_max: 5
stabilization_threshold: 0.1
accumulated_error_threshold: 50
short_ema_params:
max_alpha: 0.6
halflife_sec: 301
precision: 3
safety_mode:
check_outdoor_sensor: false
input_number:
fake_temperature_sensor1:
name: Temperature
min: 0
max: 35
step: .1
icon: mdi:thermometer
unit_of_measurement: °C
mode: box
fake_external_temperature_sensor1:
name: Ext Temperature
min: -10
max: 35
step: .1
icon: mdi:home-thermometer
unit_of_measurement: °C
mode: box
fake_current_power:
name: Current power
min: 0
max: 1000
step: 10
icon: mdi:flash
unit_of_measurement: kW
fake_current_power_max:
name: Current power max threshold
min: 0
max: 1000
step: 10
icon: mdi:flash
unit_of_measurement: kW
fake_valve1:
name: The valve 1
min: 10
max: 90
icon: mdi:pipe-valve
unit_of_measurement: percentage
fake_boiler_temperature:
name: Central thermostat temp
min: 0
max: 30
icon: mdi:thermostat
unit_of_measurement: °C
mode: box
fake_offset_calibration1:
name: Sonoff offset calibration 1
min: -12
max: 12
icon: mdi:tune
unit_of_measurement: °C
mode: box
fake_opening_degree1:
name: Sonoff Opening degree 1
min: 0
max: 100
icon: mdi:valve-open
unit_of_measurement: "%"
mode: box
fake_closing_degree1:
name: Sonoff Closing degree 1
min: 0
max: 100
icon: mdi:valve-closed
unit_of_measurement: "%"
mode: box
fake_offset_calibration2:
name: Sonoff offset calibration 2
min: -12
max: 12
icon: mdi:tune
unit_of_measurement: °C
mode: box
fake_opening_degree2:
name: Sonoff Opening degree 2
min: 0
max: 100
icon: mdi:valve-open
unit_of_measurement: "%"
mode: box
fake_closing_degree2:
name: Sonoff Closing degree 2
min: 0
max: 100
icon: mdi:valve-closed
unit_of_measurement: "%"
mode: box
input_boolean:
# input_boolean to simulate the windows entity. Only for development environment.
fake_window_sensor1:
name: Window 1
icon: mdi:window-closed-variant
# input_boolean to simulate the heater entity switch. Only for development environment.
fake_heater_switch3:
name: Heater 3
icon: mdi:radiator
fake_heater_switch2:
name: Heater 2
icon: mdi:radiator
fake_heater_switch1:
name: Heater 1
icon: mdi:radiator
fake_heater_ac1:
name: Air contionner 1
icon: mdi:air-conditioner
fake_heater_4switch1:
name: Heater (multiswitch1)
icon: mdi:radiator
fake_heater_4switch2:
name: Heater (multiswitch2)
icon: mdi:radiator
fake_heater_4switch3:
name: Heater (multiswitch3)
icon: mdi:radiator
fake_heater_4switch4:
name: Heater (multiswitch4)
icon: mdi:radiator
fake_heater_4climate1:
name: Heater (multiclimate1)
icon: mdi:radiator
fake_heater_4climate2:
name: Heater (multiclimate2)
icon: mdi:radiator
fake_heater_4climate3:
name: Heater (multiclimate3)
icon: mdi:radiator
fake_heater_4climate4:
name: Heater (multiclimate4)
icon: mdi:radiator
# input_boolean to simulate the motion sensor entity. Only for development environment.
fake_motion_sensor1:
name: Motion Sensor 1
icon: mdi:run
# input_boolean to simulate the presence sensor entity. Only for development environment.
fake_presence_sensor1:
name: Presence Sensor 1
icon: mdi:home
fake_valve_sonoff_trvzb1:
name: Valve Sonoff TRVZB1
icon: mdi:valve
fake_valve_sonoff_trvzb2:
name: Valve Sonoff TRVZB2
icon: mdi:valve
fake_inversed_heater:
name: Inversed Heater
icon: mdi:radiator-off
climate:
- platform: generic_thermostat
name: Underlying thermostat1
heater: input_boolean.fake_heater_switch3
target_sensor: input_number.fake_temperature_sensor1
- platform: generic_thermostat
name: Underlying thermostat2
heater: input_boolean.fake_heater_switch3
target_sensor: input_number.fake_temperature_sensor1
ac_mode: false
- platform: generic_thermostat
name: Underlying thermostat3
heater: input_boolean.fake_heater_switch3
target_sensor: input_number.fake_temperature_sensor1
- platform: generic_thermostat
name: Underlying thermostat4
heater: input_boolean.fake_heater_switch3
target_sensor: input_number.fake_temperature_sensor1
- platform: generic_thermostat
name: Underlying thermostat 4-1
heater: input_boolean.fake_heater_4climate1
target_sensor: input_number.fake_temperature_sensor1
ac_mode: false
- platform: generic_thermostat
name: Underlying thermostat 4-2
heater: input_boolean.fake_heater_4climate2
target_sensor: input_number.fake_temperature_sensor1
ac_mode: false
- platform: generic_thermostat
name: Underlying thermostat 4-3
heater: input_boolean.fake_heater_4climate3
target_sensor: input_number.fake_temperature_sensor1
ac_mode: false
- platform: generic_thermostat
name: Underlying thermostat 4-4
heater: input_boolean.fake_heater_4climate4
target_sensor: input_number.fake_temperature_sensor1
ac_mode: false
- platform: generic_thermostat
name: Underlying thermostat9
heater: input_boolean.fake_heater_switch3
target_sensor: input_number.fake_temperature_sensor1
- platform: generic_thermostat
name: Underlying Sonoff TRVZB1
heater: input_boolean.fake_valve_sonoff_trvzb1
target_sensor: input_number.fake_temperature_sensor1
ac_mode: false
- platform: generic_thermostat
name: Underlying Sonoff TRVZB2
heater: input_boolean.fake_valve_sonoff_trvzb2
target_sensor: input_number.fake_temperature_sensor1
ac_mode: false
- platform: generic_thermostat
name: Underlying switch climate
heater: input_boolean.fake_heater_switch2
target_sensor: input_number.fake_temperature_sensor1
ac_mode: false
input_datetime:
fake_last_seen:
name: Last seen temp sensor
icon: mdi:update
has_date: true
has_time: true
template:
- binary_sensor:
- name: maison_occupee
unique_id: maison_occupee
state: "{{is_state('person.jmc', 'home') }}"
device_class: occupancy
- sensor:
- name: "Total énergie switch1"
unique_id: total_energie_switch1
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
state: >
{% set energy = state_attr('climate.thermostat_switch_1', 'total_energy') | float(default=-1) %}
{% if energy < 0 %}{{none}}{% else %}
{{ energy | round(2, default=0) }}
{% endif %}
- name: "Total énergie climate 2"
unique_id: total_energie_climate2
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
state: >
{% set energy = state_attr('climate.thermostat_climate_2', 'total_energy') | float(default=-1) %}
{% if energy < 0 %}{{none}}{% else %}
{{ energy | round(2, default=0) }}
{% endif %}
- name: "Total énergie chambre"
unique_id: total_energie_chambre
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
state: >
{% set energy = state_attr('climate.thermostat_chambre', 'total_energy') | float(default=-1) %}
{% if energy < 0 %}{{none}}{% else %}
{{ energy | round(2, default=0) }}
{% endif %}
switch:
- platform: template
switches:
pilote_sdb_rdc:
friendly_name: "Pilote chauffage SDB RDC"
value_template: "{{ is_state_attr('switch_seche_serviettes_sdb_rdc', 'sensor_state', 'on') }}"
turn_on:
action: select.select_option
data:
option: comfort
target:
entity_id: select.seche_serviettes_sdb_rdc_cable_outlet_mode
turn_off:
action: select.select_option
data:
option: comfort-2
target:
entity_id: select.seche_serviettes_sdb_rdc_cable_outlet_mode
- platform: template
switches:
fake_inversed_switch:
friendly_name: "A fake inversed switch"
value_template: "{{ is_state('input_boolean.fake_inversed_heater', 'on') }}"
turn_on:
action: input_boolean.turn_on
data: {}
target:
entity_id: input_boolean.fake_inversed_heater
turn_off:
action: input_boolean.turn_off
data: {}
target:
entity_id: input_boolean.fake_inversed_heater
frontend:
extra_module_url:
- /config/www/community/versatile-thermostat-ui-card/versatile-thermostat-ui-card.js
themes:
versatile_thermostat_theme:
state-binary_sensor-safety-on-color: "#FF0B0B"
state-binary_sensor-power-on-color: "#FF0B0B"
state-binary_sensor-window-on-color: "rgb(156, 39, 176)"
state-binary_sensor-motion-on-color: "rgb(156, 39, 176)"
state-binary_sensor-presence-on-color: "lightgreen"
state-binary_sensor-running-on-color: "orange"