--- name: Issue about: Create a report to help us improve --- > Please read carefuly this instructions and fill this form before writing an issue. It helps me to help you. ## Version of the custom_component ## Configuration My VTherm attributes are the following: ```yaml hvac_modes: - heat - 'off' min_temp: 7 max_temp: 35 preset_modes: - none - eco - comfort - boost - activity current_temperature: 18.9 temperature: 22 hvac_action: 'off' preset_mode: security hvac_mode: 'off' type: null eco_temp: 17 boost_temp: 20 comfort_temp: 19 eco_away_temp: 16.1 boost_away_temp: 16.3 comfort_away_temp: 16.2 power_temp: 13 ext_current_temperature: 11.6 ac_mode: false current_power: 450 current_power_max: 910 saved_preset_mode: none saved_target_temp: 22 saved_hvac_mode: heat window_state: 'on' motion_state: 'off' overpowering_state: false presence_state: 'on' window_auto_state: false window_bypass_state: false security_delay_min: 2 security_min_on_percent: 0.5 security_default_on_percent: 0.1 last_temperature_datetime: '2023-11-05T00:48:54.873157+01:00' last_ext_temperature_datetime: '2023-11-05T00:48:53.240122+01:00' security_state: true minimal_activation_delay_sec: 1 device_power: 300 mean_cycle_power: 30 total_energy: 137.5 last_update_datetime: '2023-11-05T00:51:54.901140+01:00' timezone: Europe/Paris window_sensor_entity_id: input_boolean.fake_window_sensor1 window_delay_sec: 20 window_auto_open_threshold: null window_auto_close_threshold: null window_auto_max_duration: null motion_sensor_entity_id: input_boolean.fake_motion_sensor1 presence_sensor_entity_id: input_boolean.fake_presence_sensor1 power_sensor_entity_id: input_number.fake_current_power max_power_sensor_entity_id: input_number.fake_current_power_max is_over_switch: true underlying_switch_0: input_boolean.fake_heater_switch1 underlying_switch_1: null underlying_switch_2: null underlying_switch_3: null on_percent: 0.1 on_time_sec: 6 off_time_sec: 54 cycle_min: 1 function: tpi tpi_coef_int: 0.6 tpi_coef_ext: 0.01 friendly_name: Thermostat switch 1 supported_features: 17 ``` ## If it is releveant to regulation performance or optimisation some curves are needed To have a great curves demonstrating what you think is a problem, please install and configure what is described here: [Even better with Plotly to tune your Thermostat](#even-better-with-plotly-to-tune-your-thermostat) ## Describe the bug A clear and concise description of what the bug is. I'm trying to: And I expect: But I observe this .... I read the documentation on the README.md file and I don't find any relevant information about this issue. ## Debug log ```yaml logger: default: info logs: custom_components.versatile_thermostat: info ``` ```text Add your logs here. ```