Compare commits

..

2 Commits

Author SHA1 Message Date
Jean-Marc Collin
73a9ca4e53 Issue #478 vtherm doesn't follow underlying (#548)
* Dispatch test_bugs into each own VTherm type tests

* Local tests ok

* With testus ok.

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-10-13 11:30:04 +02:00
Jean-Marc Collin
1334bdbd8f FIX #465 and make this coherent with Windows open/close (#545)
Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
2024-10-12 17:32:05 +02:00
13 changed files with 1118 additions and 875 deletions

View File

@@ -1,14 +1,30 @@
default_config: default_config:
recorder:
auto_purge: true
purge_keep_days: 1
commit_interval: 5
include:
domains:
- input_boolean
- input_number
- switch
- climate
- sensor
- binary_sensor
- number
- input_select
- versatile_thermostat
logger: logger:
default: warning default: warning
logs: logs:
custom_components.versatile_thermostat: debug custom_components.versatile_thermostat: debug
# custom_components.versatile_thermostat.underlyings: info # custom_components.versatile_thermostat.underlyings: info
# custom_components.versatile_thermostat.climate: info # custom_components.versatile_thermostat.climate: info
# custom_components.versatile_thermostat.base_thermostat: debug # custom_components.versatile_thermostat.base_thermostat: debug
custom_components.versatile_thermostat.sensor: info custom_components.versatile_thermostat.sensor: info
custom_components.versatile_thermostat.binary_sensor: info custom_components.versatile_thermostat.binary_sensor: info
# If you need to debug uncommment the line below (doc: https://www.home-assistant.io/integrations/debugpy/) # If you need to debug uncommment the line below (doc: https://www.home-assistant.io/integrations/debugpy/)
debugpy: debugpy:
@@ -176,20 +192,6 @@ input_datetime:
has_date: true has_date: true
has_time: true has_time: true
recorder:
commit_interval: 0
include:
domains:
- input_boolean
- input_number
- switch
- climate
- sensor
- binary_sensor
- number
- input_select
- versatile_thermostat
template: template:
- binary_sensor: - binary_sensor:
- name: maison_occupee - name: maison_occupee

View File

@@ -15,10 +15,12 @@ from homeassistant.core import (
callback, callback,
Event, Event,
State, State,
) )
from homeassistant.components.climate import ClimateEntity from homeassistant.components.climate import ClimateEntity
from homeassistant.helpers.restore_state import RestoreEntity from homeassistant.helpers.restore_state import RestoreEntity
from homeassistant.helpers.entity import Entity
from homeassistant.config_entries import ConfigEntry from homeassistant.config_entries import ConfigEntry
from homeassistant.helpers.device_registry import DeviceInfo, DeviceEntryType from homeassistant.helpers.device_registry import DeviceInfo, DeviceEntryType
@@ -1159,10 +1161,17 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
return len(self._underlyings) return len(self._underlyings)
@property @property
def underlying_entities(self) -> int: def underlying_entities(self) -> list | None:
"""Returns the underlying entities""" """Returns the underlying entities"""
return self._underlyings return self._underlyings
def find_underlying_by_entity_id(self, entity_id: str) -> Entity | None:
"""Get the underlying entity by a entity_id"""
for under in self._underlyings:
if under.entity_id == entity_id:
return under
return None
@property @property
def is_on(self) -> bool: def is_on(self) -> bool:
"""True if the VTherm is on (! HVAC_OFF)""" """True if the VTherm is on (! HVAC_OFF)"""

View File

@@ -3,6 +3,7 @@
import logging import logging
from datetime import timedelta, datetime from datetime import timedelta, datetime
from homeassistant.const import STATE_ON
from homeassistant.core import Event, HomeAssistant, State, callback from homeassistant.core import Event, HomeAssistant, State, callback
from homeassistant.helpers.event import ( from homeassistant.helpers.event import (
async_track_state_change_event, async_track_state_change_event,
@@ -56,6 +57,13 @@ from .underlyings import UnderlyingClimate
_LOGGER = logging.getLogger(__name__) _LOGGER = logging.getLogger(__name__)
HVAC_ACTION_ON = [ # pylint: disable=invalid-name
HVACAction.COOLING,
HVACAction.DRYING,
HVACAction.FAN,
HVACAction.HEATING,
]
class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]): class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
"""Representation of a base class for a Versatile Thermostat over a climate""" """Representation of a base class for a Versatile Thermostat over a climate"""
@@ -635,6 +643,15 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
if not new_state: if not new_state:
return return
# Find the underlying which have change
under = self.find_underlying_by_entity_id(new_state.entity_id)
if not under:
_LOGGER.warning(
"We have a receive an event from entity %s which is NOT one of our underlying entities. This is not normal and should be reported to the developper of the integration"
)
return
changes = False changes = False
new_hvac_mode = new_state.state new_hvac_mode = new_state.state
@@ -669,20 +686,44 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
new_state.last_updated if new_state and new_state.last_updated else None new_state.last_updated if new_state and new_state.last_updated else None
) )
new_target_temp = (
new_state.attributes.get("temperature")
if new_state and new_state.attributes
else None
)
# Issue 99 - some AC turn hvac_mode=cool and hvac_action=idle when sending a HVACMode_OFF command # Issue 99 - some AC turn hvac_mode=cool and hvac_action=idle when sending a HVACMode_OFF command
# Issue 114 - Remove this because hvac_mode is now managed by local _hvac_mode and use idle action as is # Issue 114 - Remove this because hvac_mode is now managed by local _hvac_mode and use idle action as is
# if self._hvac_mode == HVACMode.OFF and new_hvac_action == HVACAction.IDLE: # if self._hvac_mode == HVACMode.OFF and new_hvac_action == HVACAction.IDLE:
# _LOGGER.debug("The underlying switch to idle instead of OFF. We will consider it as OFF") # _LOGGER.debug("The underlying switch to idle instead of OFF. We will consider it as OFF")
# new_hvac_mode = HVACMode.OFF # new_hvac_mode = HVACMode.OFF
# Forget event when the event holds no real changes
if (
new_hvac_mode == self._hvac_mode
and new_hvac_action == old_hvac_action
and new_target_temp is None
and (new_fan_mode is None or new_fan_mode == self._attr_fan_mode)
):
_LOGGER.debug(
"%s - a underlying state change event is received but no real change have been found. Forget the event",
self,
)
return
# A real changes have to be managed
_LOGGER.info( _LOGGER.info(
"%s - Underlying climate %s changed. Event.new_hvac_mode is %s, current_hvac_mode=%s, new_hvac_action=%s, old_hvac_action=%s", "%s - Underlying climate %s have changed. new_hvac_mode is %s (vs %s), new_hvac_action=%s (vs %s), new_target_temp=%s (vs %s), new_fan_mode=%s (vs %s)",
self, self,
new_state.entity_id, under.entity_id,
new_hvac_mode, new_hvac_mode,
self._hvac_mode, self._hvac_mode,
new_hvac_action, new_hvac_action,
old_hvac_action, old_hvac_action,
new_target_temp,
self.target_temperature,
new_fan_mode,
self._attr_fan_mode,
) )
_LOGGER.debug( _LOGGER.debug(
@@ -696,12 +737,6 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
) )
# Interpretation of hvac action # Interpretation of hvac action
HVAC_ACTION_ON = [ # pylint: disable=invalid-name
HVACAction.COOLING,
HVACAction.DRYING,
HVACAction.FAN,
HVACAction.HEATING,
]
if old_hvac_action not in HVAC_ACTION_ON and new_hvac_action in HVAC_ACTION_ON: if old_hvac_action not in HVAC_ACTION_ON and new_hvac_action in HVAC_ACTION_ON:
self._underlying_climate_start_hvac_action_date = ( self._underlying_climate_start_hvac_action_date = (
self.get_last_updated_date_or_now(new_state) self.get_last_updated_date_or_now(new_state)
@@ -734,6 +769,7 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
) )
changes = True changes = True
# Filter new state when received just after a change from VTherm
# Issue #120 - Some TRV are changing target temperature a very long time (6 sec) after the change. # Issue #120 - Some TRV are changing target temperature a very long time (6 sec) after the change.
# In that case a loop is possible if a user change multiple times during this 6 sec. # In that case a loop is possible if a user change multiple times during this 6 sec.
if new_state_date_updated and self._last_change_time: if new_state_date_updated and self._last_change_time:
@@ -746,6 +782,7 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
await end_climate_changed(changes) await end_climate_changed(changes)
return return
# Update all underlyings hvac_mode state if it has change
if ( if (
new_hvac_mode new_hvac_mode
in [ in [
@@ -760,7 +797,6 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
] ]
and self._hvac_mode != new_hvac_mode and self._hvac_mode != new_hvac_mode
): ):
# Update all underlyings state
# Issue #334 - if all underlyings are not aligned with the same hvac_mode don't change the underlying and wait they are aligned # Issue #334 - if all underlyings are not aligned with the same hvac_mode don't change the underlying and wait they are aligned
if self.is_over_climate: if self.is_over_climate:
for under in self._underlyings: for under in self._underlyings:
@@ -791,27 +827,31 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
self._attr_fan_mode = new_fan_mode self._attr_fan_mode = new_fan_mode
changes = True changes = True
# try to manage new target temperature set if state if no other changes have been found
if not changes: if not changes:
# try to manage new target temperature set if state
_LOGGER.debug( _LOGGER.debug(
"Do temperature check. temperature is %s, new_state.attributes is %s", "Do temperature check. under.last_sent_temperature is %s, new_target_temp is %s",
self.target_temperature, under.last_sent_temperature,
new_state.attributes, new_target_temp,
) )
if ( if (
# we do not change target temperature on regulated VTherm # if the underlying have change its target temperature
not self.is_regulated new_target_temp is not None
and new_state.attributes and new_target_temp != under.last_sent_temperature
and (new_target_temp := new_state.attributes.get("temperature"))
and new_target_temp != self.target_temperature
): ):
_LOGGER.info( _LOGGER.info(
"%s - Target temp in underlying have change to %s", "%s - Target temp in underlying have change to %s (vs %s)",
self, self,
new_target_temp, new_target_temp,
under.last_sent_temperature,
) )
await self.async_set_temperature(temperature=new_target_temp) await self.async_set_temperature(temperature=new_target_temp)
changes = True changes = True
else:
_LOGGER.debug(
"%s - Forget the eventual underlying temperature change because VTherm is regulated",
self,
)
await end_climate_changed(changes) await end_climate_changed(changes)
@@ -1104,3 +1144,29 @@ class ThermostatOverClimate(BaseThermostat[UnderlyingClimate]):
self.choose_auto_fan_mode(CONF_AUTO_FAN_TURBO) self.choose_auto_fan_mode(CONF_AUTO_FAN_TURBO)
self.update_custom_attributes() self.update_custom_attributes()
@overrides
async def async_turn_off(self) -> None:
# if window is open, don't overwrite the saved_hvac_mode
if self.window_state != STATE_ON:
self.save_hvac_mode()
await self.async_set_hvac_mode(HVACMode.OFF)
@overrides
async def async_turn_on(self) -> None:
# don't turn_on if window is open
if self.window_state == STATE_ON:
_LOGGER.info(
"%s - refuse to turn on because window is open. We keep the save_hvac_mode",
self,
)
return
if self._saved_hvac_mode is not None: # pylint: disable=protected-access
await self.restore_hvac_mode(True)
else:
if self._ac_mode:
await self.async_set_hvac_mode(HVACMode.COOL)
else:
await self.async_set_hvac_mode(HVACMode.HEAT)

View File

@@ -488,6 +488,7 @@ class UnderlyingClimate(UnderlyingEntity):
entity_id=climate_entity_id, entity_id=climate_entity_id,
) )
self._underlying_climate = None self._underlying_climate = None
self._last_sent_temperature = None
def find_underlying_climate(self) -> ClimateEntity: def find_underlying_climate(self) -> ClimateEntity:
"""Find the underlying climate entity""" """Find the underlying climate entity"""
@@ -637,6 +638,13 @@ class UnderlyingClimate(UnderlyingEntity):
data, data,
) )
self._last_sent_temperature = target_temp
@property
def last_sent_temperature(self) -> float | None:
"""Get the last send temperature. None if no temperature have been sent yet"""
return self._last_sent_temperature
@property @property
def hvac_action(self) -> HVACAction | None: def hvac_action(self) -> HVACAction | None:
"""Get the hvac action of the underlying""" """Get the hvac action of the underlying"""
@@ -721,6 +729,13 @@ class UnderlyingClimate(UnderlyingEntity):
return 15 return 15
return self._underlying_climate.target_temperature_low return self._underlying_climate.target_temperature_low
@property
def target_temperature(self) -> float:
"""Get the target_temperature"""
if not self.is_initialized:
return None
return self._underlying_climate.target_temperature
@property @property
def is_aux_heat(self) -> bool: def is_aux_heat(self) -> bool:
"""Get the is_aux_heat""" """Get the is_aux_heat"""

View File

@@ -1,4 +1,4 @@
# pylint: disable=wildcard-import, unused-wildcard-import, protected-access, unused-argument, line-too-long, abstract-method # pylint: disable=wildcard-import, unused-wildcard-import, protected-access, unused-argument, line-too-long, abstract-method, too-many-lines, redefined-builtin
""" Some common resources """ """ Some common resources """
import asyncio import asyncio
@@ -931,6 +931,7 @@ async def send_climate_change_event_with_temperature(
date, date,
temperature, temperature,
sleep=True, sleep=True,
underlying_entity_id=None,
): ):
"""Sending a new climate event simulating a change on the underlying climate state""" """Sending a new climate event simulating a change on the underlying climate state"""
_LOGGER.info( _LOGGER.info(
@@ -943,18 +944,21 @@ async def send_climate_change_event_with_temperature(
temperature, temperature,
entity, entity,
) )
if not underlying_entity_id:
underlying_entity_id = entity.entity_id
climate_event = Event( climate_event = Event(
EVENT_STATE_CHANGED, EVENT_STATE_CHANGED,
{ {
"new_state": State( "new_state": State(
entity_id=entity.entity_id, entity_id=underlying_entity_id,
state=new_hvac_mode, state=new_hvac_mode,
attributes={"hvac_action": new_hvac_action, "temperature": temperature}, attributes={"hvac_action": new_hvac_action, "temperature": temperature},
last_changed=date, last_changed=date,
last_updated=date, last_updated=date,
), ),
"old_state": State( "old_state": State(
entity_id=entity.entity_id, entity_id=underlying_entity_id,
state=old_hvac_mode, state=old_hvac_mode,
attributes={"hvac_action": old_hvac_action}, attributes={"hvac_action": old_hvac_action},
last_changed=date, last_changed=date,

View File

@@ -1,4 +1,4 @@
# pylint: disable=wildcard-import, unused-wildcard-import, protected-access, unused-argument, line-too-long # pylint: disable=wildcard-import, unused-wildcard-import, protected-access, unused-argument, line-too-long, too-many-lines
""" Test the Window management """ """ Test the Window management """
import asyncio import asyncio
@@ -8,7 +8,8 @@ from datetime import datetime, timedelta
import logging import logging
from homeassistant.core import HomeAssistant, State from homeassistant.const import STATE_ON, STATE_OFF
from homeassistant.core import HomeAssistant
from homeassistant.components.climate import ( from homeassistant.components.climate import (
SERVICE_SET_TEMPERATURE, SERVICE_SET_TEMPERATURE,
) )
@@ -16,7 +17,6 @@ from homeassistant.components.climate import (
from custom_components.versatile_thermostat.config_flow import ( from custom_components.versatile_thermostat.config_flow import (
VersatileThermostatBaseConfigFlow, VersatileThermostatBaseConfigFlow,
) )
from custom_components.versatile_thermostat.thermostat_valve import ThermostatOverValve
from custom_components.versatile_thermostat.thermostat_climate import ( from custom_components.versatile_thermostat.thermostat_climate import (
ThermostatOverClimate, ThermostatOverClimate,
) )
@@ -29,83 +29,6 @@ from .commons import *
logging.getLogger().setLevel(logging.DEBUG) logging.getLogger().setLevel(logging.DEBUG)
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_56(
hass: HomeAssistant,
skip_hass_states_is_state,
skip_turn_on_off_heater,
skip_send_event,
):
"""Test that in over_climate mode there is no error when underlying climate is not available"""
the_mock_underlying = MagicMockClimate()
with patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=None, # dont find the underlying climate
):
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverClimateMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 19,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
},
)
entity: BaseThermostat = await create_thermostat(
hass, entry, "climate.theoverclimatemockname"
)
assert entity
# cause the underlying climate was not found
assert entity.is_over_climate is True
assert entity.underlying_entity(0)._underlying_climate is None
# Should not failed
entity.update_custom_attributes()
# try to call async_control_heating
try:
ret = await entity.async_control_heating()
# an exception should be send
assert ret is False
except Exception: # pylint: disable=broad-exception-caught
assert False
# This time the underlying will be found
with patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=the_mock_underlying, # dont find the underlying climate
):
# try to call async_control_heating
try:
await entity.async_control_heating()
except UnknownEntity:
assert False
except Exception: # pylint: disable=broad-exception-caught
assert False
# Should not failed
entity.update_custom_attributes()
@pytest.mark.parametrize("expected_lingering_tasks", [True]) @pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True]) @pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_63( async def test_bug_63(
@@ -205,391 +128,6 @@ async def test_bug_64(
assert entity assert entity
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_66(
hass: HomeAssistant,
skip_hass_states_is_state,
skip_turn_on_off_heater,
skip_send_event,
):
"""Test that it should be possible to open/close the window rapidly without side effect"""
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverSwitchMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverSwitchMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_SWITCH,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 19,
CONF_USE_WINDOW_FEATURE: True,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_HEATER: "switch.mock_switch",
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1, # !! here
CONF_DEVICE_POWER: 200,
CONF_WINDOW_SENSOR: "binary_sensor.mock_window_sensor",
CONF_WINDOW_DELAY: 0, # important to not been obliged to wait
},
)
entity: BaseThermostat = await create_thermostat(
hass, entry, "climate.theoverswitchmockname"
)
assert entity
await entity.async_set_hvac_mode(HVACMode.HEAT)
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 19
assert entity.window_state is STATE_OFF
# Open the window and let the thermostat shut down
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off, patch(
"homeassistant.helpers.condition.state", return_value=True
) as mock_condition, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.is_device_active",
return_value=True,
):
await send_temperature_change_event(entity, 15, now)
try_window_condition = await send_window_change_event(
entity, True, False, now, False
)
# simulate the call to try_window_condition
await try_window_condition(None)
assert mock_send_event.call_count == 1
assert mock_heater_on.call_count == 1
assert mock_heater_off.call_count >= 1
assert mock_condition.call_count == 1
assert entity.window_state == STATE_ON
# Close the window but too shortly
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off, patch(
"homeassistant.helpers.condition.state", return_value=False
) as mock_condition, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.is_device_active",
return_value=False,
):
event_timestamp = now + timedelta(minutes=1)
try_window_condition = await send_window_change_event(
entity, False, True, event_timestamp
)
# simulate the call to try_window_condition
await try_window_condition(None)
# window state should not have change
assert entity.window_state == STATE_ON
# Reopen immediatly with sufficient time
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off, patch(
"homeassistant.helpers.condition.state", return_value=True
) as mock_condition, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.is_device_active",
return_value=False,
):
try_window_condition = await send_window_change_event(
entity, True, False, event_timestamp
)
# simulate the call to try_window_condition
await try_window_condition(None)
# still no change
assert entity.window_state == STATE_ON
assert entity.hvac_mode == HVACMode.OFF
# Close the window but with sufficient time this time
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off, patch(
"homeassistant.helpers.condition.state", return_value=True
) as mock_condition, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.is_device_active",
return_value=False,
):
event_timestamp = now + timedelta(minutes=2)
try_window_condition = await send_window_change_event(
entity, False, True, event_timestamp
)
# simulate the call to try_window_condition
await try_window_condition(None)
# window state should be Off this time and old state should have been restored
assert entity.window_state == STATE_OFF
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_82(
hass: HomeAssistant,
skip_hass_states_is_state,
skip_turn_on_off_heater,
skip_send_event,
):
"""Test that when a underlying climate is not available the VTherm doesn't go into safety mode"""
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
data=PARTIAL_CLIMATE_CONFIG, # 5 minutes security delay
)
fake_underlying_climate = MockUnavailableClimate(
hass, "mockUniqueId", "MockClimateName", {}
)
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=fake_underlying_climate,
) as mock_find_climate:
entity = await create_thermostat(hass, entry, "climate.theoverclimatemockname")
# entry.add_to_hass(hass)
# await hass.config_entries.async_setup(entry.entry_id)
# assert entry.state is ConfigEntryState.LOADED
#
# def find_my_entity(entity_id) -> ClimateEntity:
# """Find my new entity"""
# component: EntityComponent[ClimateEntity] = hass.data[CLIMATE_DOMAIN]
# for entity in component.entities:
# if entity.entity_id == entity_id:
# return entity
#
# entity = find_my_entity("climate.theoverclimatemockname")
assert entity
assert entity.name == "TheOverClimateMockName"
assert entity.is_over_climate is True
# assert entity.hvac_action is HVACAction.OFF
assert entity.hvac_mode is HVACMode.OFF
# assert entity.hvac_mode is None
assert entity.target_temperature == entity.min_temp
assert entity.preset_modes == [
PRESET_NONE,
PRESET_FROST_PROTECTION,
PRESET_ECO,
PRESET_COMFORT,
PRESET_BOOST,
]
assert entity.preset_mode is PRESET_NONE
assert entity._security_state is False
# should have been called with EventType.PRESET_EVENT and EventType.HVAC_MODE_EVENT
assert mock_send_event.call_count == 2
mock_send_event.assert_has_calls(
[
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_NONE}),
call.send_event(
EventType.HVAC_MODE_EVENT,
{"hvac_mode": HVACMode.OFF},
),
]
)
assert mock_find_climate.call_count == 1
assert mock_find_climate.mock_calls[0] == call()
mock_find_climate.assert_has_calls([call.find_underlying_entity()])
# Force safety mode
assert entity._last_ext_temperature_measure is not None
assert entity._last_temperature_measure is not None
assert (
entity._last_temperature_measure.astimezone(tz) - now
).total_seconds() < 1
assert (
entity._last_ext_temperature_measure.astimezone(tz) - now
).total_seconds() < 1
# Tries to turns on the Thermostat
await entity.async_set_hvac_mode(HVACMode.HEAT)
assert entity.hvac_mode == HVACMode.HEAT
# 2. activate security feature when date is expired
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
):
event_timestamp = now - timedelta(minutes=6)
# set temperature to 15 so that on_percent will be > security_min_on_percent (0.2)
await send_temperature_change_event(entity, 15, event_timestamp)
# Should stay False
assert entity.security_state is False
assert entity.preset_mode == "none"
assert entity._saved_preset_mode == "none"
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_101(
hass: HomeAssistant,
skip_hass_states_is_state,
skip_turn_on_off_heater,
skip_send_event,
):
"""Test that when a underlying climate target temp is changed, the VTherm change its own temperature target and switch to manual"""
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
data=PARTIAL_CLIMATE_NOT_REGULATED_CONFIG, # 5 minutes security delay
)
# Underlying is in HEAT mode but should be shutdown at startup
fake_underlying_climate = MockClimate(
hass, "mockUniqueId", "MockClimateName", {}, HVACMode.HEAT, HVACAction.HEATING
)
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=fake_underlying_climate,
) as mock_find_climate, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.set_hvac_mode"
) as mock_underlying_set_hvac_mode:
entity = await create_thermostat(hass, entry, "climate.theoverclimatemockname")
# entry.add_to_hass(hass)
# await hass.config_entries.async_setup(entry.entry_id)
# assert entry.state is ConfigEntryState.LOADED
#
# def find_my_entity(entity_id) -> ClimateEntity:
# """Find my new entity"""
# component: EntityComponent[ClimateEntity] = hass.data[CLIMATE_DOMAIN]
# for entity in component.entities:
# if entity.entity_id == entity_id:
# return entity
#
# entity = find_my_entity("climate.theoverclimatemockname")
assert entity
assert entity.name == "TheOverClimateMockName"
assert entity.is_over_climate is True
assert entity.hvac_mode is HVACMode.OFF
# because in MockClimate HVACAction is HEATING if hvac_mode is not set
assert entity.hvac_action is HVACAction.HEATING
# Underlying should have been shutdown
assert mock_underlying_set_hvac_mode.call_count == 1
mock_underlying_set_hvac_mode.assert_has_calls(
[
call.set_hvac_mode(HVACMode.OFF),
]
)
assert entity.target_temperature == entity.min_temp
assert entity.preset_mode is PRESET_NONE
# should have been called with EventType.PRESET_EVENT and EventType.HVAC_MODE_EVENT
assert mock_send_event.call_count == 2
mock_send_event.assert_has_calls(
[
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_NONE}),
call.send_event(
EventType.HVAC_MODE_EVENT,
{"hvac_mode": HVACMode.OFF},
),
]
)
assert mock_find_climate.call_count == 1
assert mock_find_climate.mock_calls[0] == call()
mock_find_climate.assert_has_calls([call.find_underlying_entity()])
# Force preset mode
await entity.async_set_hvac_mode(HVACMode.HEAT)
assert entity.hvac_mode == HVACMode.HEAT
await entity.async_set_preset_mode(PRESET_COMFORT)
assert entity.preset_mode == PRESET_COMFORT
# 2. Change the target temp of underlying thermostat at now -> the event will be disgarded because to fast (to avoid loop cf issue 121)
await send_climate_change_event_with_temperature(
entity,
HVACMode.HEAT,
HVACMode.HEAT,
HVACAction.OFF,
HVACAction.OFF,
now,
12.75,
)
# Should NOT have been switched to Manual preset
assert entity.target_temperature == 17
assert entity.preset_mode is PRESET_COMFORT
# 2. Change the target temp of underlying thermostat at 11 sec later -> the event will be taken
# Wait 11 sec
event_timestamp = now + timedelta(seconds=11)
assert entity.is_regulated is False
await send_climate_change_event_with_temperature(
entity,
HVACMode.HEAT,
HVACMode.HEAT,
HVACAction.OFF,
HVACAction.OFF,
event_timestamp,
12.75,
)
assert entity.target_temperature == 12.75
assert entity.preset_mode is PRESET_NONE
@pytest.mark.parametrize("expected_lingering_tasks", [True]) @pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True]) @pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_272( async def test_bug_272(
@@ -861,174 +399,6 @@ async def test_bug_407(hass: HomeAssistant, skip_hass_states_is_state):
assert entity.overpowering_state is True assert entity.overpowering_state is True
async def test_bug_339(
hass: HomeAssistant,
# skip_hass_states_is_state,
init_central_config_with_boiler_fixture,
):
"""Test that the counter of active Vtherm in central boiler is
correctly updated with underlying is in auto and device is active
"""
api = VersatileThermostatAPI.get_vtherm_api(hass)
climate1 = MockClimate(
hass=hass,
unique_id="climate1",
name="theClimate1",
hvac_mode=HVACMode.AUTO,
hvac_modes=[HVACMode.AUTO, HVACMode.OFF, HVACMode.HEAT, HVACMode.COOL],
hvac_action=HVACAction.HEATING,
)
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverClimateMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 8,
CONF_TEMP_MAX: 18,
"frost_temp": 10,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 21,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: climate1.entity_id,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_USE_MAIN_CENTRAL_CONFIG: True,
CONF_USE_PRESETS_CENTRAL_CONFIG: True,
CONF_USE_ADVANCED_CENTRAL_CONFIG: True,
CONF_USED_BY_CENTRAL_BOILER: True,
},
)
with patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=climate1,
):
entity: ThermostatOverValve = await create_thermostat(
hass, entry, "climate.theoverclimatemockname"
)
assert entity
assert entity.name == "TheOverClimateMockName"
assert entity.is_over_climate
assert entity.underlying_entities[0].entity_id == "climate.climate1"
assert api.nb_active_device_for_boiler_threshold == 1
await entity.async_set_hvac_mode(HVACMode.AUTO)
# Simulate a state change in underelying
await api.nb_active_device_for_boiler_entity.calculate_nb_active_devices(None)
# The VTherm should be active
assert entity.underlying_entity(0).is_device_active is True
assert entity.is_device_active is True
assert api.nb_active_device_for_boiler == 1
entity.remove_thermostat()
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_508(
hass: HomeAssistant,
skip_hass_states_is_state,
skip_turn_on_off_heater,
skip_send_event,
):
"""Test that it not possible to set the target temperature under the min_temp setting"""
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
# default value are min 15°, max 31°, step 0.1
data=PARTIAL_CLIMATE_CONFIG, # 5 minutes security delay
)
# Min_temp is 10 and max_temp is 31 and features contains TARGET_TEMPERATURE_RANGE
fake_underlying_climate = MagicMockClimateWithTemperatureRange()
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
), patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=fake_underlying_climate,
), patch(
"homeassistant.core.ServiceRegistry.async_call"
) as mock_service_call:
entity = await create_thermostat(hass, entry, "climate.theoverclimatemockname")
assert entity
assert entity.name == "TheOverClimateMockName"
assert entity.is_over_climate is True
assert entity.hvac_mode is HVACMode.OFF
# The VTherm value and not the underlying value
assert entity.target_temperature_step == 0.1
assert entity.target_temperature == entity.min_temp
assert entity.is_regulated is True
assert mock_service_call.call_count == 0
# Set the hvac_mode to HEAT
await entity.async_set_hvac_mode(HVACMode.HEAT)
# Not In the accepted interval -> should be converted into 10 (the min) and send with target_temp_high and target_temp_low
await entity.async_set_temperature(temperature=8.5)
# MagicMock climate is already HEAT by default. So there is no SET_HAVC_MODE call
assert mock_service_call.call_count == 1
mock_service_call.assert_has_calls(
[
call.async_call(
"climate",
SERVICE_SET_TEMPERATURE,
{
"entity_id": "climate.mock_climate",
# "temperature": 17.5,
"target_temp_high": 10,
"target_temp_low": 10,
"temperature": 10,
},
),
]
)
with patch("homeassistant.core.ServiceRegistry.async_call") as mock_service_call:
# Not In the accepted interval -> should be converted into 10 (the min) and send with target_temp_high and target_temp_low
await entity.async_set_temperature(temperature=32)
# MagicMock climate is already HEAT by default. So there is no SET_HAVC_MODE call
assert mock_service_call.call_count == 1
mock_service_call.assert_has_calls(
[
call.async_call(
"climate",
SERVICE_SET_TEMPERATURE,
{
"entity_id": "climate.mock_climate",
"target_temp_high": 31,
"target_temp_low": 31,
"temperature": 31,
},
),
]
)
@pytest.mark.parametrize("expected_lingering_tasks", [True]) @pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True]) @pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_500_1(hass: HomeAssistant, init_vtherm_api) -> None: async def test_bug_500_1(hass: HomeAssistant, init_vtherm_api) -> None:
@@ -1100,10 +470,10 @@ async def test_bug_500_3(hass: HomeAssistant, init_vtherm_api) -> None:
@pytest.mark.parametrize("expected_lingering_tasks", [True]) @pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True]) @pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_524(hass: HomeAssistant, skip_hass_states_is_state): async def test_bug_465(hass: HomeAssistant, skip_hass_states_is_state):
"""Test when switching from Cool to Heat the new temperature in Heat mode should be used""" """Test store and restore hvac_mode on toggle hvac state"""
vtherm_api: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api(hass) # vtherm_api: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api(hass)
# The temperatures to set # The temperatures to set
temps = { temps = {
@@ -1123,6 +493,8 @@ async def test_bug_524(hass: HomeAssistant, skip_hass_states_is_state):
"boost_ac_away": 23.1, "boost_ac_away": 23.1,
} }
# 0. initialisation
config_entry = MockConfigEntry( config_entry = MockConfigEntry(
domain=DOMAIN, domain=DOMAIN,
title="TheOverClimateMockName", title="TheOverClimateMockName",
@@ -1135,7 +507,10 @@ async def test_bug_524(hass: HomeAssistant, skip_hass_states_is_state):
CONF_CYCLE_MIN: 5, CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15, CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30, CONF_TEMP_MAX: 30,
CONF_USE_WINDOW_FEATURE: False, CONF_USE_WINDOW_FEATURE: True,
CONF_WINDOW_SENSOR: "binary_sensor.window_sensor",
CONF_WINDOW_ACTION: CONF_WINDOW_TURN_OFF,
CONF_WINDOW_DELAY: 1,
CONF_USE_MOTION_FEATURE: False, CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False, CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: True, CONF_USE_PRESENCE_FEATURE: True,
@@ -1147,7 +522,6 @@ async def test_bug_524(hass: HomeAssistant, skip_hass_states_is_state):
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO, CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True, CONF_AC_MODE: True,
}, },
# | temps,
) )
fake_underlying_climate = MockClimate( fake_underlying_climate = MockClimate(
@@ -1164,215 +538,78 @@ async def test_bug_524(hass: HomeAssistant, skip_hass_states_is_state):
vtherm: ThermostatOverClimate = await create_thermostat( vtherm: ThermostatOverClimate = await create_thermostat(
hass, config_entry, "climate.overclimate" hass, config_entry, "climate.overclimate"
) )
assert vtherm is not None
assert vtherm is not None await set_all_climate_preset_temp(hass, vtherm, temps, "overclimate")
# We search for NumberEntities now: datetime = datetime.now(tz=get_tz(hass))
for preset_name, value in temps.items():
await set_climate_preset_temp(vtherm, preset_name, value)
temp_entity: NumberEntity = search_entity(
hass,
"number.overclimate_preset_" + preset_name + PRESET_TEMP_SUFFIX,
NUMBER_DOMAIN,
)
assert temp_entity
# Because set_value is not implemented in Number class (really don't understand why...)
assert temp_entity.state == value
# 1. Set mode to Heat and preset to Comfort # 1. Set mode to Heat and preset to Comfort
await send_presence_change_event(vtherm, True, False, datetime.now()) await send_presence_change_event(vtherm, True, False, datetime.now())
await vtherm.async_set_hvac_mode(HVACMode.HEAT) await vtherm.async_set_hvac_mode(HVACMode.HEAT)
await vtherm.async_set_preset_mode(PRESET_COMFORT) await vtherm.async_set_preset_mode(PRESET_BOOST)
await hass.async_block_till_done() await hass.async_block_till_done()
assert vtherm.target_temperature == 19.0 assert vtherm.target_temperature == 21.0
# 2. Only change the HVAC_MODE (and keep preset to comfort) # 2. Toggle the VTherm state
await vtherm.async_toggle()
await hass.async_block_till_done()
assert vtherm.hvac_mode == HVACMode.OFF
# 3. (re)Toggle the VTherm state
await vtherm.async_toggle()
await hass.async_block_till_done()
assert vtherm.hvac_mode == HVACMode.HEAT
# 4. Toggle from COOL
await vtherm.async_set_hvac_mode(HVACMode.COOL) await vtherm.async_set_hvac_mode(HVACMode.COOL)
await hass.async_block_till_done() await hass.async_block_till_done()
assert vtherm.target_temperature == 25.0
# 3. Only change the HVAC_MODE (and keep preset to comfort) assert vtherm.target_temperature == 23.0
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
# 5. Toggle the VTherm state
await vtherm.async_toggle()
await hass.async_block_till_done() await hass.async_block_till_done()
assert vtherm.target_temperature == 19.0 assert vtherm.hvac_mode == HVACMode.OFF
# 4. Change presence to off # 6. (re)Toggle the VTherm state
await send_presence_change_event(vtherm, False, True, datetime.now()) await vtherm.async_toggle()
await hass.async_block_till_done() await hass.async_block_till_done()
assert vtherm.target_temperature == 19.1 assert vtherm.hvac_mode == HVACMode.COOL
# 5. Change hvac_mode to AC ###
await vtherm.async_set_hvac_mode(HVACMode.COOL) # Same test with an open window and initial state is COOL
await hass.async_block_till_done() #
assert vtherm.target_temperature == 25.1 # 7. open the window
with patch("homeassistant.helpers.condition.state", return_value=True):
# 6. Change presence to on try_window_condition = await send_window_change_event(
await send_presence_change_event(vtherm, True, False, datetime.now()) vtherm, True, False, now, False
await hass.async_block_till_done() )
assert vtherm.target_temperature == 25 await try_window_condition(None)
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_533(hass: HomeAssistant, skip_hass_states_is_state):
"""Test that with an over_valve and _auto_regulation_dpercent is set that the valve could close totally"""
vtherm_api: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api(hass)
# The temperatures to set
temps = {
"frost": 7.0,
"eco": 17.0,
"comfort": 19.0,
"boost": 21.0,
}
config_entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverValveMockName",
unique_id="overValveUniqueId",
data={
CONF_NAME: "overValve",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_VALVE,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.5,
CONF_TPI_COEF_EXT: 0,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_VALVE: "number.mock_valve",
CONF_AUTO_REGULATION_DTEMP: 10, # This parameter makes the bug
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 60,
},
# | temps,
)
# Not used because number is not registred so we can use directly the underlying number
# fake_underlying_number = MockNumber(
# hass=hass, unique_id="mock_number", name="mock_number"
# )
vtherm: ThermostatOverClimate = await create_thermostat(
hass, config_entry, "climate.overvalve"
)
assert vtherm is not None
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
# Set all temps and check they are correctly initialized
await set_all_climate_preset_temp(hass, vtherm, temps, "overvalve")
await send_temperature_change_event(vtherm, 15, now)
await send_ext_temperature_change_event(vtherm, 15, now)
# 1. Set mode to Heat and preset to Comfort
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
with patch(
"homeassistant.core.StateMachine.get",
return_value=State(
entity_id="number.mock_valve",
state="100",
attributes={"min": 0, "max": 100},
),
), patch("homeassistant.core.ServiceRegistry.async_call") as mock_service_call:
await vtherm.async_set_preset_mode(PRESET_COMFORT)
await hass.async_block_till_done() await hass.async_block_till_done()
assert vtherm.target_temperature == 19.0 assert vtherm.window_state is STATE_ON
assert mock_service_call.call_count == 1 assert vtherm.hvac_mode == HVACMode.OFF
mock_service_call.assert_has_calls(
[
call.async_call(
domain="number",
service="set_value",
service_data={"value": 100},
target={"entity_id": "number.mock_valve"},
),
]
)
# 2. set current temperature to 18 -> still 50% open, so there is a call # 8. call toggle -> we should stay in OFF (command is ignored)
now = now + timedelta(minutes=1) await vtherm.async_toggle()
with patch( await hass.async_block_till_done()
"homeassistant.core.StateMachine.get", assert vtherm.hvac_mode == HVACMode.OFF
return_value=State(
entity_id="number.mock_valve", # 9. Close the window (we should come back to Cool this time)
state="100", now = now + timedelta(minutes=2)
attributes={"min": 0, "max": 100}, with patch("homeassistant.helpers.condition.state", return_value=True):
), try_window_condition = await send_window_change_event(
), patch("homeassistant.core.ServiceRegistry.async_call") as mock_service_call: vtherm, False, True, now, False
await send_temperature_change_event(vtherm, 18, now) )
await try_window_condition(None)
await hass.async_block_till_done() await hass.async_block_till_done()
assert mock_service_call.call_count == 1 assert vtherm.window_state is STATE_OFF
mock_service_call.assert_has_calls( assert vtherm.hvac_mode == HVACMode.COOL
[
call.async_call(
domain="number",
service="set_value",
service_data={"value": 50},
target={"entity_id": "number.mock_valve"},
),
]
)
# 3. set current temperature to 18.8 -> still 10% open, so there is one call # 9. call toggle -> we should come back in OFF
now = now + timedelta(minutes=1) await vtherm.async_toggle()
with patch( await hass.async_block_till_done()
"homeassistant.core.StateMachine.get", assert vtherm.hvac_mode == HVACMode.OFF
return_value=State(
entity_id="number.mock_valve",
state="50",
attributes={"min": 0, "max": 100},
),
), patch("homeassistant.core.ServiceRegistry.async_call") as mock_service_call:
await send_temperature_change_event(vtherm, 18.8, now)
await hass.async_block_till_done()
assert mock_service_call.call_count == 1
mock_service_call.assert_has_calls(
[
call.async_call(
domain="number",
service="set_value",
service_data={"value": 10},
target={"entity_id": "number.mock_valve"},
),
]
)
# 4. set current temperature to 19 -> should have 0% open and one call to set the 0
now = now + timedelta(minutes=1)
with patch(
"homeassistant.core.StateMachine.get",
return_value=State(
entity_id="number.mock_valve",
state="10", # the previous value
attributes={"min": 0, "max": 100},
),
), patch("homeassistant.core.ServiceRegistry.async_call") as mock_service_call:
await send_temperature_change_event(vtherm, 19, now)
await hass.async_block_till_done()
assert mock_service_call.call_count == 1
mock_service_call.assert_has_calls(
[
call.async_call(
domain="number",
service="set_value",
service_data={"value": 0},
target={"entity_id": "number.mock_valve"},
),
]
)

View File

@@ -842,3 +842,80 @@ async def test_update_central_boiler_state_simple_climate(
assert boiler_binary_sensor.state == STATE_OFF assert boiler_binary_sensor.state == STATE_OFF
entity.remove_thermostat() entity.remove_thermostat()
async def test_bug_339(
hass: HomeAssistant,
# skip_hass_states_is_state,
init_central_config_with_boiler_fixture,
):
"""Test that the counter of active Vtherm in central boiler is
correctly updated with underlying is in auto and device is active
"""
api = VersatileThermostatAPI.get_vtherm_api(hass)
climate1 = MockClimate(
hass=hass,
unique_id="climate1",
name="theClimate1",
hvac_mode=HVACMode.AUTO,
hvac_modes=[HVACMode.AUTO, HVACMode.OFF, HVACMode.HEAT, HVACMode.COOL],
hvac_action=HVACAction.HEATING,
)
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverClimateMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 8,
CONF_TEMP_MAX: 18,
"frost_temp": 10,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 21,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: climate1.entity_id,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1,
CONF_USE_MAIN_CENTRAL_CONFIG: True,
CONF_USE_PRESETS_CENTRAL_CONFIG: True,
CONF_USE_ADVANCED_CENTRAL_CONFIG: True,
CONF_USED_BY_CENTRAL_BOILER: True,
},
)
with patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=climate1,
):
entity: ThermostatOverValve = await create_thermostat(
hass, entry, "climate.theoverclimatemockname"
)
assert entity
assert entity.name == "TheOverClimateMockName"
assert entity.is_over_climate
assert entity.underlying_entities[0].entity_id == "climate.climate1"
assert api.nb_active_device_for_boiler_threshold == 1
await entity.async_set_hvac_mode(HVACMode.AUTO)
# Simulate a state change in underelying
await api.nb_active_device_for_boiler_entity.calculate_nb_active_devices(None)
# The VTherm should be active
assert entity.underlying_entity(0).is_device_active is True
assert entity.is_device_active is True
assert api.nb_active_device_for_boiler == 1
entity.remove_thermostat()

View File

@@ -596,6 +596,7 @@ async def test_multiple_climates_underlying_changes(
HVACAction.IDLE, HVACAction.IDLE,
HVACAction.OFF, HVACAction.OFF,
event_timestamp, event_timestamp,
underlying_entity_id="switch.mock_climate3",
) )
# Should be call for all Switch # Should be call for all Switch

508
tests/test_overclimate.py Normal file
View File

@@ -0,0 +1,508 @@
# pylint: disable=wildcard-import, unused-wildcard-import, protected-access, unused-argument, line-too-long, too-many-lines
""" Test the Window management """
from unittest.mock import patch, call
from datetime import datetime, timedelta
import logging
from homeassistant.core import HomeAssistant
from homeassistant.components.climate import (
SERVICE_SET_TEMPERATURE,
)
from custom_components.versatile_thermostat.thermostat_climate import (
ThermostatOverClimate,
)
from .commons import *
logging.getLogger().setLevel(logging.DEBUG)
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_56(
hass: HomeAssistant,
skip_hass_states_is_state,
skip_turn_on_off_heater,
skip_send_event,
):
"""Test that in over_climate mode there is no error when underlying climate is not available"""
the_mock_underlying = MagicMockClimate()
with patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=None, # dont find the underlying climate
):
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverClimateMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 19,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
},
)
entity: BaseThermostat = await create_thermostat(
hass, entry, "climate.theoverclimatemockname"
)
assert entity
# cause the underlying climate was not found
assert entity.is_over_climate is True
assert entity.underlying_entity(0)._underlying_climate is None
# Should not failed
entity.update_custom_attributes()
# try to call async_control_heating
try:
ret = await entity.async_control_heating()
# an exception should be send
assert ret is False
except Exception: # pylint: disable=broad-exception-caught
assert False
# This time the underlying will be found
with patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=the_mock_underlying, # dont find the underlying climate
):
# try to call async_control_heating
try:
await entity.async_control_heating()
except UnknownEntity:
assert False
except Exception: # pylint: disable=broad-exception-caught
assert False
# Should not failed
entity.update_custom_attributes()
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_82(
hass: HomeAssistant,
skip_hass_states_is_state,
skip_turn_on_off_heater,
skip_send_event,
):
"""Test that when a underlying climate is not available the VTherm doesn't go into safety mode"""
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
data=PARTIAL_CLIMATE_CONFIG, # 5 minutes security delay
)
fake_underlying_climate = MockUnavailableClimate(
hass, "mockUniqueId", "MockClimateName", {}
)
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=fake_underlying_climate,
) as mock_find_climate:
entity = await create_thermostat(hass, entry, "climate.theoverclimatemockname")
assert entity
assert entity.name == "TheOverClimateMockName"
assert entity.is_over_climate is True
# assert entity.hvac_action is HVACAction.OFF
assert entity.hvac_mode is HVACMode.OFF
# assert entity.hvac_mode is None
assert entity.target_temperature == entity.min_temp
assert entity.preset_modes == [
PRESET_NONE,
PRESET_FROST_PROTECTION,
PRESET_ECO,
PRESET_COMFORT,
PRESET_BOOST,
]
assert entity.preset_mode is PRESET_NONE
assert entity._security_state is False
# should have been called with EventType.PRESET_EVENT and EventType.HVAC_MODE_EVENT
assert mock_send_event.call_count == 2
mock_send_event.assert_has_calls(
[
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_NONE}),
call.send_event(
EventType.HVAC_MODE_EVENT,
{"hvac_mode": HVACMode.OFF},
),
]
)
assert mock_find_climate.call_count == 1
assert mock_find_climate.mock_calls[0] == call()
mock_find_climate.assert_has_calls([call.find_underlying_entity()])
# Force safety mode
assert entity._last_ext_temperature_measure is not None
assert entity._last_temperature_measure is not None
assert (
entity._last_temperature_measure.astimezone(tz) - now
).total_seconds() < 1
assert (
entity._last_ext_temperature_measure.astimezone(tz) - now
).total_seconds() < 1
# Tries to turns on the Thermostat
await entity.async_set_hvac_mode(HVACMode.HEAT)
assert entity.hvac_mode == HVACMode.HEAT
# 2. activate security feature when date is expired
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
):
event_timestamp = now - timedelta(minutes=6)
# set temperature to 15 so that on_percent will be > security_min_on_percent (0.2)
await send_temperature_change_event(entity, 15, event_timestamp)
# Should stay False
assert entity.security_state is False
assert entity.preset_mode == "none"
assert entity._saved_preset_mode == "none"
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_101(
hass: HomeAssistant,
skip_hass_states_is_state,
skip_turn_on_off_heater,
skip_send_event,
):
"""Test that when a underlying climate target temp is changed, the VTherm change its own temperature target and switch to manual"""
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
data=PARTIAL_CLIMATE_NOT_REGULATED_CONFIG, # 5 minutes security delay
)
# Underlying is in HEAT mode but should be shutdown at startup
fake_underlying_climate = MockClimate(
hass, "mockUniqueId", "MockClimateName", {}, HVACMode.HEAT, HVACAction.HEATING
)
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=fake_underlying_climate,
) as mock_find_climate, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.set_hvac_mode"
) as mock_underlying_set_hvac_mode:
entity = await create_thermostat(hass, entry, "climate.theoverclimatemockname")
assert entity
assert entity.name == "TheOverClimateMockName"
assert entity.is_over_climate is True
assert entity.hvac_mode is HVACMode.OFF
# because in MockClimate HVACAction is HEATING if hvac_mode is not set
assert entity.hvac_action is HVACAction.HEATING
# Underlying should have been shutdown
assert mock_underlying_set_hvac_mode.call_count == 1
mock_underlying_set_hvac_mode.assert_has_calls(
[
call.set_hvac_mode(HVACMode.OFF),
]
)
assert entity.target_temperature == entity.min_temp
assert entity.preset_mode is PRESET_NONE
# should have been called with EventType.PRESET_EVENT and EventType.HVAC_MODE_EVENT
assert mock_send_event.call_count == 2
mock_send_event.assert_has_calls(
[
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_NONE}),
call.send_event(
EventType.HVAC_MODE_EVENT,
{"hvac_mode": HVACMode.OFF},
),
]
)
assert mock_find_climate.call_count == 1
assert mock_find_climate.mock_calls[0] == call()
mock_find_climate.assert_has_calls([call.find_underlying_entity()])
# 1. Force preset mode
await entity.async_set_hvac_mode(HVACMode.HEAT)
assert entity.hvac_mode == HVACMode.HEAT
await entity.async_set_preset_mode(PRESET_COMFORT)
assert entity.preset_mode == PRESET_COMFORT
# 2. Change the target temp of underlying thermostat at now -> the event will be disgarded because to fast (to avoid loop cf issue 121)
await send_climate_change_event_with_temperature(
entity,
HVACMode.HEAT,
HVACMode.HEAT,
HVACAction.OFF,
HVACAction.OFF,
now,
12.75,
True,
"climate.mock_climate", # the underlying climate entity id
)
# Should NOT have been switched to Manual preset
assert entity.target_temperature == 17
assert entity.preset_mode is PRESET_COMFORT
# 3. Change the target temp of underlying thermostat at 11 sec later -> the event will be taken
# Wait 11 sec
event_timestamp = now + timedelta(seconds=11)
assert entity.is_regulated is False
await send_climate_change_event_with_temperature(
entity,
HVACMode.HEAT,
HVACMode.HEAT,
HVACAction.OFF,
HVACAction.OFF,
event_timestamp,
12.75,
True,
"climate.mock_climate", # the underlying climate entity id
)
assert entity.target_temperature == 12.75
assert entity.preset_mode is PRESET_NONE
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_508(
hass: HomeAssistant,
skip_hass_states_is_state,
skip_turn_on_off_heater,
skip_send_event,
):
"""Test that it not possible to set the target temperature under the min_temp setting"""
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="uniqueId",
# default value are min 15°, max 31°, step 0.1
data=PARTIAL_CLIMATE_CONFIG, # 5 minutes security delay
)
# Min_temp is 10 and max_temp is 31 and features contains TARGET_TEMPERATURE_RANGE
fake_underlying_climate = MagicMockClimateWithTemperatureRange()
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
), patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=fake_underlying_climate,
), patch(
"homeassistant.core.ServiceRegistry.async_call"
) as mock_service_call:
entity = await create_thermostat(hass, entry, "climate.theoverclimatemockname")
assert entity
assert entity.name == "TheOverClimateMockName"
assert entity.is_over_climate is True
assert entity.hvac_mode is HVACMode.OFF
# The VTherm value and not the underlying value
assert entity.target_temperature_step == 0.1
assert entity.target_temperature == entity.min_temp
assert entity.is_regulated is True
assert mock_service_call.call_count == 0
# Set the hvac_mode to HEAT
await entity.async_set_hvac_mode(HVACMode.HEAT)
# Not In the accepted interval -> should be converted into 10 (the min) and send with target_temp_high and target_temp_low
await entity.async_set_temperature(temperature=8.5)
# MagicMock climate is already HEAT by default. So there is no SET_HAVC_MODE call
assert mock_service_call.call_count == 1
mock_service_call.assert_has_calls(
[
call.async_call(
"climate",
SERVICE_SET_TEMPERATURE,
{
"entity_id": "climate.mock_climate",
# "temperature": 17.5,
"target_temp_high": 10,
"target_temp_low": 10,
"temperature": 10,
},
),
]
)
with patch("homeassistant.core.ServiceRegistry.async_call") as mock_service_call:
# Not In the accepted interval -> should be converted into 10 (the min) and send with target_temp_high and target_temp_low
await entity.async_set_temperature(temperature=32)
# MagicMock climate is already HEAT by default. So there is no SET_HAVC_MODE call
assert mock_service_call.call_count == 1
mock_service_call.assert_has_calls(
[
call.async_call(
"climate",
SERVICE_SET_TEMPERATURE,
{
"entity_id": "climate.mock_climate",
"target_temp_high": 31,
"target_temp_low": 31,
"temperature": 31,
},
),
]
)
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_524(hass: HomeAssistant, skip_hass_states_is_state):
"""Test when switching from Cool to Heat the new temperature in Heat mode should be used"""
# vtherm_api: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api(hass)
# The temperatures to set
temps = {
"frost": 7.0,
"eco": 17.0,
"comfort": 19.0,
"boost": 21.0,
"eco_ac": 27.0,
"comfort_ac": 25.0,
"boost_ac": 23.0,
"frost_away": 7.1,
"eco_away": 17.1,
"comfort_away": 19.1,
"boost_away": 21.1,
"eco_ac_away": 27.1,
"comfort_ac_away": 25.1,
"boost_ac_away": 23.1,
}
config_entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverClimateMockName",
unique_id="overClimateUniqueId",
data={
CONF_NAME: "overClimate",
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: True,
CONF_PRESENCE_SENSOR: "binary_sensor.presence_sensor",
CONF_CLIMATE: "climate.mock_climate",
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
CONF_AUTO_FAN_MODE: CONF_AUTO_FAN_TURBO,
CONF_AC_MODE: True,
},
# | temps,
)
fake_underlying_climate = MockClimate(
hass=hass,
unique_id="mock_climate",
name="mock_climate",
hvac_modes=[HVACMode.OFF, HVACMode.COOL, HVACMode.HEAT, HVACMode.FAN_ONLY],
)
with patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.find_underlying_climate",
return_value=fake_underlying_climate,
):
vtherm: ThermostatOverClimate = await create_thermostat(
hass, config_entry, "climate.overclimate"
)
assert vtherm is not None
# We search for NumberEntities
for preset_name, value in temps.items():
await set_climate_preset_temp(vtherm, preset_name, value)
temp_entity: NumberEntity = search_entity(
hass,
"number.overclimate_preset_" + preset_name + PRESET_TEMP_SUFFIX,
NUMBER_DOMAIN,
)
assert temp_entity
# Because set_value is not implemented in Number class (really don't understand why...)
assert temp_entity.state == value
# 1. Set mode to Heat and preset to Comfort
await send_presence_change_event(vtherm, True, False, datetime.now())
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
await vtherm.async_set_preset_mode(PRESET_COMFORT)
await hass.async_block_till_done()
assert vtherm.target_temperature == 19.0
# 2. Only change the HVAC_MODE (and keep preset to comfort)
await vtherm.async_set_hvac_mode(HVACMode.COOL)
await hass.async_block_till_done()
assert vtherm.target_temperature == 25.0
# 3. Only change the HVAC_MODE (and keep preset to comfort)
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
await hass.async_block_till_done()
assert vtherm.target_temperature == 19.0
# 4. Change presence to off
await send_presence_change_event(vtherm, False, True, datetime.now())
await hass.async_block_till_done()
assert vtherm.target_temperature == 19.1
# 5. Change hvac_mode to AC
await vtherm.async_set_hvac_mode(HVACMode.COOL)
await hass.async_block_till_done()
assert vtherm.target_temperature == 25.1
# 6. Change presence to on
await send_presence_change_event(vtherm, True, False, datetime.now())
await hass.async_block_till_done()
assert vtherm.target_temperature == 25

View File

@@ -433,6 +433,7 @@ async def test_power_management_energy_over_climate(
new_hvac_action=HVACAction.HEATING, new_hvac_action=HVACAction.HEATING,
old_hvac_action=HVACAction.OFF, old_hvac_action=HVACAction.OFF,
date=event_timestamp, date=event_timestamp,
underlying_entity_id="climate.mock_climate",
) )
# We have the start event and not the end event # We have the start event and not the end event
assert (entity._underlying_climate_start_hvac_action_date - now).total_seconds() < 1 assert (entity._underlying_climate_start_hvac_action_date - now).total_seconds() < 1
@@ -448,6 +449,7 @@ async def test_power_management_energy_over_climate(
new_hvac_action=HVACAction.IDLE, new_hvac_action=HVACAction.IDLE,
old_hvac_action=HVACAction.HEATING, old_hvac_action=HVACAction.HEATING,
date=now, date=now,
underlying_entity_id="climate.mock_climate",
) )
# We have the end event -> we should have some power and on_percent # We have the end event -> we should have some power and on_percent
assert entity._underlying_climate_start_hvac_action_date is None assert entity._underlying_climate_start_hvac_action_date is None

View File

@@ -283,6 +283,7 @@ async def test_sensors_over_climate(
new_hvac_action=HVACAction.HEATING, new_hvac_action=HVACAction.HEATING,
old_hvac_action=HVACAction.OFF, old_hvac_action=HVACAction.OFF,
date=event_timestamp, date=event_timestamp,
underlying_entity_id="climate.mock_climate",
) )
# Send a climate_change event with HVACAction=IDLE (end of heating) # Send a climate_change event with HVACAction=IDLE (end of heating)
@@ -293,6 +294,7 @@ async def test_sensors_over_climate(
new_hvac_action=HVACAction.IDLE, new_hvac_action=HVACAction.IDLE,
old_hvac_action=HVACAction.HEATING, old_hvac_action=HVACAction.HEATING,
date=now, date=now,
underlying_entity_id="climate.mock_climate",
) )
# 60 minutes heating with 1.5 kW heating -> 1.5 kWh # 60 minutes heating with 1.5 kW heating -> 1.5 kWh

View File

@@ -6,10 +6,6 @@ from datetime import datetime, timedelta
from homeassistant.core import HomeAssistant, State from homeassistant.core import HomeAssistant, State
from homeassistant.components.climate import HVACAction, HVACMode from homeassistant.components.climate import HVACAction, HVACMode
from homeassistant.config_entries import ConfigEntryState
from homeassistant.helpers.entity_component import EntityComponent
from homeassistant.components.climate import ClimateEntity, DOMAIN as CLIMATE_DOMAIN
from pytest_homeassistant_custom_component.common import MockConfigEntry from pytest_homeassistant_custom_component.common import MockConfigEntry
@@ -551,3 +547,168 @@ async def test_over_valve_regulation(
assert mock_service_call.call_count == 0 assert mock_service_call.call_count == 0
assert mock_send_event.call_count == 0 assert mock_send_event.call_count == 0
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_533(
hass: HomeAssistant, skip_hass_states_is_state
): # pylint: disable=unused-argument
"""Test that with an over_valve and _auto_regulation_dpercent is set that the valve could close totally"""
# vtherm_api: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api(hass)
# The temperatures to set
temps = {
"frost": 7.0,
"eco": 17.0,
"comfort": 19.0,
"boost": 21.0,
}
config_entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverValveMockName",
unique_id="overValveUniqueId",
data={
CONF_NAME: "overValve",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_VALVE,
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.5,
CONF_TPI_COEF_EXT: 0,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
CONF_USE_WINDOW_FEATURE: False,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_VALVE: "number.mock_valve",
CONF_AUTO_REGULATION_DTEMP: 10, # This parameter makes the bug
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 60,
},
# | temps,
)
# Not used because number is not registred so we can use directly the underlying number
# fake_underlying_number = MockNumber(
# hass=hass, unique_id="mock_number", name="mock_number"
# )
vtherm: ThermostatOverValve = await create_thermostat(
hass, config_entry, "climate.overvalve"
)
assert vtherm is not None
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
# Set all temps and check they are correctly initialized
await set_all_climate_preset_temp(hass, vtherm, temps, "overvalve")
await send_temperature_change_event(vtherm, 15, now)
await send_ext_temperature_change_event(vtherm, 15, now)
# 1. Set mode to Heat and preset to Comfort
await vtherm.async_set_hvac_mode(HVACMode.HEAT)
with patch(
"homeassistant.core.StateMachine.get",
return_value=State(
entity_id="number.mock_valve",
state="100",
attributes={"min": 0, "max": 100},
),
), patch("homeassistant.core.ServiceRegistry.async_call") as mock_service_call:
await vtherm.async_set_preset_mode(PRESET_COMFORT)
await hass.async_block_till_done()
assert vtherm.target_temperature == 19.0
assert mock_service_call.call_count == 1
mock_service_call.assert_has_calls(
[
call.async_call(
domain="number",
service="set_value",
service_data={"value": 100},
target={"entity_id": "number.mock_valve"},
),
]
)
# 2. set current temperature to 18 -> still 50% open, so there is a call
now = now + timedelta(minutes=1)
with patch(
"homeassistant.core.StateMachine.get",
return_value=State(
entity_id="number.mock_valve",
state="100",
attributes={"min": 0, "max": 100},
),
), patch("homeassistant.core.ServiceRegistry.async_call") as mock_service_call:
await send_temperature_change_event(vtherm, 18, now)
await hass.async_block_till_done()
assert mock_service_call.call_count == 1
mock_service_call.assert_has_calls(
[
call.async_call(
domain="number",
service="set_value",
service_data={"value": 50},
target={"entity_id": "number.mock_valve"},
),
]
)
# 3. set current temperature to 18.8 -> still 10% open, so there is one call
now = now + timedelta(minutes=1)
with patch(
"homeassistant.core.StateMachine.get",
return_value=State(
entity_id="number.mock_valve",
state="50",
attributes={"min": 0, "max": 100},
),
), patch("homeassistant.core.ServiceRegistry.async_call") as mock_service_call:
await send_temperature_change_event(vtherm, 18.8, now)
await hass.async_block_till_done()
assert mock_service_call.call_count == 1
mock_service_call.assert_has_calls(
[
call.async_call(
domain="number",
service="set_value",
service_data={"value": 10},
target={"entity_id": "number.mock_valve"},
),
]
)
# 4. set current temperature to 19 -> should have 0% open and one call to set the 0
now = now + timedelta(minutes=1)
with patch(
"homeassistant.core.StateMachine.get",
return_value=State(
entity_id="number.mock_valve",
state="10", # the previous value
attributes={"min": 0, "max": 100},
),
), patch("homeassistant.core.ServiceRegistry.async_call") as mock_service_call:
await send_temperature_change_event(vtherm, 19, now)
await hass.async_block_till_done()
assert mock_service_call.call_count == 1
mock_service_call.assert_has_calls(
[
call.async_call(
domain="number",
service="set_value",
service_data={"value": 0},
target={"entity_id": "number.mock_valve"},
),
]
)

View File

@@ -1925,3 +1925,162 @@ async def test_window_action_frost_temp(hass: HomeAssistant, skip_hass_states_is
# Clean the entity # Clean the entity
entity.remove_thermostat() entity.remove_thermostat()
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_bug_66(
hass: HomeAssistant,
skip_hass_states_is_state,
skip_turn_on_off_heater,
skip_send_event,
):
"""Test that it should be possible to open/close the window rapidly without side effect"""
tz = get_tz(hass) # pylint: disable=invalid-name
now: datetime = datetime.now(tz=tz)
entry = MockConfigEntry(
domain=DOMAIN,
title="TheOverSwitchMockName",
unique_id="uniqueId",
data={
CONF_NAME: "TheOverSwitchMockName",
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_SWITCH,
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
"eco_temp": 17,
"comfort_temp": 18,
"boost_temp": 19,
CONF_USE_WINDOW_FEATURE: True,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_HEATER: "switch.mock_switch",
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
CONF_TPI_COEF_INT: 0.3,
CONF_TPI_COEF_EXT: 0.01,
CONF_MINIMAL_ACTIVATION_DELAY: 30,
CONF_SECURITY_DELAY_MIN: 5,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.1, # !! here
CONF_DEVICE_POWER: 200,
CONF_WINDOW_SENSOR: "binary_sensor.mock_window_sensor",
CONF_WINDOW_DELAY: 0, # important to not been obliged to wait
},
)
entity: BaseThermostat = await create_thermostat(
hass, entry, "climate.theoverswitchmockname"
)
assert entity
await entity.async_set_hvac_mode(HVACMode.HEAT)
await entity.async_set_preset_mode(PRESET_BOOST)
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST
assert entity.target_temperature == 19
assert entity.window_state is STATE_OFF
# Open the window and let the thermostat shut down
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off, patch(
"homeassistant.helpers.condition.state", return_value=True
) as mock_condition, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.is_device_active",
return_value=True,
):
await send_temperature_change_event(entity, 15, now)
try_window_condition = await send_window_change_event(
entity, True, False, now, False
)
# simulate the call to try_window_condition
await try_window_condition(None)
assert mock_send_event.call_count == 1
assert mock_heater_on.call_count == 1
assert mock_heater_off.call_count >= 1
assert mock_condition.call_count == 1
assert entity.window_state == STATE_ON
# Close the window but too shortly
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off, patch(
"homeassistant.helpers.condition.state", return_value=False
) as mock_condition, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.is_device_active",
return_value=False,
):
event_timestamp = now + timedelta(minutes=1)
try_window_condition = await send_window_change_event(
entity, False, True, event_timestamp
)
# simulate the call to try_window_condition
await try_window_condition(None)
# window state should not have change
assert entity.window_state == STATE_ON
# Reopen immediatly with sufficient time
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off, patch(
"homeassistant.helpers.condition.state", return_value=True
) as mock_condition, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.is_device_active",
return_value=False,
):
try_window_condition = await send_window_change_event(
entity, True, False, event_timestamp
)
# simulate the call to try_window_condition
await try_window_condition(None)
# still no change
assert entity.window_state == STATE_ON
assert entity.hvac_mode == HVACMode.OFF
# Close the window but with sufficient time this time
with patch(
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
) as mock_send_event, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
) as mock_heater_on, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
) as mock_heater_off, patch(
"homeassistant.helpers.condition.state", return_value=True
) as mock_condition, patch(
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.is_device_active",
return_value=False,
):
event_timestamp = now + timedelta(minutes=2)
try_window_condition = await send_window_change_event(
entity, False, True, event_timestamp
)
# simulate the call to try_window_condition
await try_window_condition(None)
# window state should be Off this time and old state should have been restored
assert entity.window_state == STATE_OFF
assert entity.hvac_mode is HVACMode.HEAT
assert entity.preset_mode is PRESET_BOOST