Issue #255 - Specify window action on window open detection
This commit is contained in:
@@ -197,6 +197,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
"window_auto_open_threshold",
|
||||
"window_auto_close_threshold",
|
||||
"window_auto_max_duration",
|
||||
"window_action",
|
||||
"motion_sensor_entity_id",
|
||||
"presence_sensor_entity_id",
|
||||
"power_sensor_entity_id",
|
||||
@@ -268,8 +269,8 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
self._window_auto_state = False
|
||||
self._window_auto_on = False
|
||||
self._window_auto_algo = None
|
||||
# PR - Adding Window ByPass
|
||||
self._window_bypass_state = False
|
||||
self._window_action = None
|
||||
|
||||
self._current_tz = dt_util.get_time_zone(self._hass.config.time_zone)
|
||||
|
||||
@@ -286,6 +287,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
self._is_central_mode = None
|
||||
self._last_central_mode = None
|
||||
self._is_used_by_central_boiler = False
|
||||
|
||||
self.post_init(entry_infos)
|
||||
|
||||
def clean_central_config_doublon(self, config_entry, central_config) -> dict:
|
||||
@@ -576,6 +578,10 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
entry_infos.get(CONF_USED_BY_CENTRAL_BOILER) is True
|
||||
)
|
||||
|
||||
self._window_action = (
|
||||
entry_infos.get(CONF_WINDOW_ACTION) or CONF_WINDOW_TURN_OFF
|
||||
)
|
||||
|
||||
_LOGGER.debug(
|
||||
"%s - Creation of a new VersatileThermostat entity: unique_id=%s",
|
||||
self,
|
||||
@@ -1092,6 +1098,11 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
"""Get the Window Bypass"""
|
||||
return self._window_bypass_state
|
||||
|
||||
@property
|
||||
def window_action(self) -> bool | None:
|
||||
"""Get the Window Action"""
|
||||
return self._window_action
|
||||
|
||||
@property
|
||||
def security_state(self) -> bool | None:
|
||||
"""Get the security_state"""
|
||||
@@ -1481,29 +1492,14 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
|
||||
self._window_state = new_state.state == STATE_ON
|
||||
|
||||
# PR - Adding Window ByPass
|
||||
_LOGGER.debug("%s - Window ByPass is : %s", self, self._window_bypass_state)
|
||||
if self._window_bypass_state:
|
||||
_LOGGER.info(
|
||||
"%s - Window ByPass is activated. Ignore window event", self
|
||||
)
|
||||
else:
|
||||
if not self._window_state:
|
||||
_LOGGER.info(
|
||||
"%s - Window is closed. Restoring hvac_mode '%s' if central_mode is not STOPPED",
|
||||
self,
|
||||
self._saved_hvac_mode,
|
||||
)
|
||||
if self.last_central_mode != CENTRAL_MODE_STOPPED:
|
||||
await self.restore_hvac_mode(True)
|
||||
elif self._window_state:
|
||||
_LOGGER.info(
|
||||
"%s - Window is open. Set hvac_mode to '%s'", self, HVACMode.OFF
|
||||
)
|
||||
if self.last_central_mode in [CENTRAL_MODE_AUTO, None]:
|
||||
self.save_hvac_mode()
|
||||
await self.change_window_detection_state(self._window_state)
|
||||
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
self.update_custom_attributes()
|
||||
|
||||
if new_state is None or old_state is None or new_state.state == old_state.state:
|
||||
@@ -1841,7 +1837,8 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
)
|
||||
# Set attributes
|
||||
self._window_auto_state = False
|
||||
await self.restore_hvac_mode(True)
|
||||
await self.change_window_detection_state(self._window_auto_state)
|
||||
# await self.restore_hvac_mode(True)
|
||||
|
||||
if self._window_call_cancel:
|
||||
self._window_call_cancel()
|
||||
@@ -1901,8 +1898,9 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
)
|
||||
# Set attributes
|
||||
self._window_auto_state = True
|
||||
self.save_hvac_mode()
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
await self.change_window_detection_state(self._window_auto_state)
|
||||
# self.save_hvac_mode()
|
||||
# await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
|
||||
# Arm the end trigger
|
||||
if self._window_call_cancel:
|
||||
@@ -2134,12 +2132,14 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
|
||||
mode_cond = self._hvac_mode != HVACMode.OFF
|
||||
|
||||
api:VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api()
|
||||
is_outdoor_checked = not api.safety_mode or api.safety_mode.get('check_outdoor_sensor') != False
|
||||
api: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api()
|
||||
is_outdoor_checked = (
|
||||
not api.safety_mode
|
||||
or api.safety_mode.get("check_outdoor_sensor") is not False
|
||||
)
|
||||
|
||||
temp_cond: bool = (
|
||||
delta_temp > self._security_delay_min
|
||||
or (is_outdoor_checked and delta_ext_temp > self._security_delay_min)
|
||||
temp_cond: bool = delta_temp > self._security_delay_min or (
|
||||
is_outdoor_checked and delta_ext_temp > self._security_delay_min
|
||||
)
|
||||
climate_cond: bool = self.is_over_climate and self.hvac_action not in [
|
||||
HVACAction.COOLING,
|
||||
@@ -2283,6 +2283,63 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
should have found the underlying climate to be operational"""
|
||||
return True
|
||||
|
||||
async def change_window_detection_state(self, new_state):
|
||||
"""Change the window detection state.
|
||||
new_state is on if an open window have been detected or off else
|
||||
"""
|
||||
if not new_state:
|
||||
_LOGGER.info(
|
||||
"%s - Window is closed. Restoring hvac_mode '%s' if central_mode is not STOPPED",
|
||||
self,
|
||||
self._saved_hvac_mode,
|
||||
)
|
||||
if self._window_action in [CONF_WINDOW_FROST_TEMP, CONF_WINDOW_ECO_TEMP]:
|
||||
await self._async_internal_set_temperature(self._saved_target_temp)
|
||||
# default to TURN_OFF
|
||||
elif self._window_action in [CONF_WINDOW_TURN_OFF, CONF_WINDOW_FAN_ONLY]:
|
||||
if self.last_central_mode != CENTRAL_MODE_STOPPED:
|
||||
await self.restore_hvac_mode(True)
|
||||
else:
|
||||
_LOGGER.error(
|
||||
"%s - undefined window_action %s. Please open a bug in the github of this project with this log",
|
||||
self,
|
||||
self._window_action,
|
||||
)
|
||||
else:
|
||||
_LOGGER.info(
|
||||
"%s - Window is open. Set hvac_mode to '%s'", self, HVACMode.OFF
|
||||
)
|
||||
if self.last_central_mode in [CENTRAL_MODE_AUTO, None]:
|
||||
if self._window_action in [CONF_WINDOW_TURN_OFF, CONF_WINDOW_FAN_ONLY]:
|
||||
self.save_hvac_mode()
|
||||
elif self._window_action in [
|
||||
CONF_WINDOW_FROST_TEMP,
|
||||
CONF_WINDOW_ECO_TEMP,
|
||||
]:
|
||||
self._saved_target_temp = self._target_temp
|
||||
|
||||
if (
|
||||
self._window_action == CONF_WINDOW_FAN_ONLY
|
||||
and HVACMode.FAN_ONLY in self.hvac_modes
|
||||
):
|
||||
await self.async_set_hvac_mode(HVACMode.FAN_ONLY)
|
||||
elif (
|
||||
self._window_action == CONF_WINDOW_FROST_TEMP
|
||||
and self._presets.get(PRESET_FROST_PROTECTION) is not None
|
||||
):
|
||||
await self._async_internal_set_temperature(
|
||||
self.find_preset_temp(PRESET_FROST_PROTECTION)
|
||||
)
|
||||
elif (
|
||||
self._window_action == CONF_WINDOW_ECO_TEMP
|
||||
and self._presets.get(PRESET_ECO) is not None
|
||||
):
|
||||
await self._async_internal_set_temperature(
|
||||
self.find_preset_temp(PRESET_ECO)
|
||||
)
|
||||
else: # default is to turn_off
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
|
||||
async def async_control_heating(self, force=False, _=None):
|
||||
"""The main function used to run the calculation at each cycle"""
|
||||
|
||||
@@ -2376,8 +2433,6 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
self.get_preset_away_name(PRESET_COMFORT)
|
||||
),
|
||||
"power_temp": self._power_temp,
|
||||
# Already in super class - "target_temp": self.target_temperature,
|
||||
# Already in super class - "current_temp": self._cur_temp,
|
||||
"target_temperature_step": self.target_temperature_step,
|
||||
"ext_current_temperature": self._cur_ext_temp,
|
||||
"ac_mode": self._ac_mode,
|
||||
@@ -2386,12 +2441,23 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
"saved_preset_mode": self._saved_preset_mode,
|
||||
"saved_target_temp": self._saved_target_temp,
|
||||
"saved_hvac_mode": self._saved_hvac_mode,
|
||||
"window_state": self.window_state,
|
||||
"motion_sensor_entity_id": self._motion_sensor_entity_id,
|
||||
"motion_state": self._motion_state,
|
||||
"power_sensor_entity_id": self._power_sensor_entity_id,
|
||||
"max_power_sensor_entity_id": self._max_power_sensor_entity_id,
|
||||
"overpowering_state": self.overpowering_state,
|
||||
"presence_sensor_entity_id": self._presence_sensor_entity_id,
|
||||
"presence_state": self._presence_state,
|
||||
"window_state": self.window_state,
|
||||
"window_auto_state": self.window_auto_state,
|
||||
"window_bypass_state": self._window_bypass_state,
|
||||
"window_sensor_entity_id": self._window_sensor_entity_id,
|
||||
"window_delay_sec": self._window_delay_sec,
|
||||
"window_auto_enabled": self.is_window_auto_enabled,
|
||||
"window_auto_open_threshold": self._window_auto_open_threshold,
|
||||
"window_auto_close_threshold": self._window_auto_close_threshold,
|
||||
"window_auto_max_duration": self._window_auto_max_duration,
|
||||
"window_action": self.window_action,
|
||||
"security_delay_min": self._security_delay_min,
|
||||
"security_min_on_percent": self._security_min_on_percent,
|
||||
"security_default_on_percent": self._security_default_on_percent,
|
||||
@@ -2410,16 +2476,6 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
.astimezone(self._current_tz)
|
||||
.isoformat(),
|
||||
"timezone": str(self._current_tz),
|
||||
"window_sensor_entity_id": self._window_sensor_entity_id,
|
||||
"window_delay_sec": self._window_delay_sec,
|
||||
"window_auto_enabled": self.is_window_auto_enabled,
|
||||
"window_auto_open_threshold": self._window_auto_open_threshold,
|
||||
"window_auto_close_threshold": self._window_auto_close_threshold,
|
||||
"window_auto_max_duration": self._window_auto_max_duration,
|
||||
"motion_sensor_entity_id": self._motion_sensor_entity_id,
|
||||
"presence_sensor_entity_id": self._presence_sensor_entity_id,
|
||||
"power_sensor_entity_id": self._power_sensor_entity_id,
|
||||
"max_power_sensor_entity_id": self._max_power_sensor_entity_id,
|
||||
"temperature_unit": self.temperature_unit,
|
||||
"is_device_active": self.is_device_active,
|
||||
"ema_temp": self._ema_temp,
|
||||
|
||||
@@ -28,7 +28,9 @@ STEP_USER_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
CONF_THERMOSTAT_TYPE, default=CONF_THERMOSTAT_SWITCH
|
||||
): selector.SelectSelector(
|
||||
selector.SelectSelectorConfig(
|
||||
options=CONF_THERMOSTAT_TYPES, translation_key="thermostat_type"
|
||||
options=CONF_THERMOSTAT_TYPES,
|
||||
translation_key="thermostat_type",
|
||||
mode="list",
|
||||
)
|
||||
)
|
||||
}
|
||||
@@ -125,6 +127,7 @@ STEP_THERMOSTAT_CLIMATE = vol.Schema( # pylint: disable=invalid-name
|
||||
selector.SelectSelectorConfig(
|
||||
options=CONF_AUTO_REGULATION_MODES,
|
||||
translation_key="auto_regulation_mode",
|
||||
mode="dropdown",
|
||||
)
|
||||
),
|
||||
vol.Optional(CONF_AUTO_REGULATION_DTEMP, default=0.5): vol.Coerce(float),
|
||||
@@ -135,6 +138,7 @@ STEP_THERMOSTAT_CLIMATE = vol.Schema( # pylint: disable=invalid-name
|
||||
selector.SelectSelectorConfig(
|
||||
options=CONF_AUTO_FAN_MODES,
|
||||
translation_key="auto_fan_mode",
|
||||
mode="dropdown",
|
||||
)
|
||||
),
|
||||
}
|
||||
@@ -212,12 +216,30 @@ STEP_CENTRAL_WINDOW_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
vol.Optional(CONF_WINDOW_AUTO_OPEN_THRESHOLD, default=3): vol.Coerce(float),
|
||||
vol.Optional(CONF_WINDOW_AUTO_CLOSE_THRESHOLD, default=0): vol.Coerce(float),
|
||||
vol.Optional(CONF_WINDOW_AUTO_MAX_DURATION, default=30): cv.positive_int,
|
||||
vol.Optional(
|
||||
CONF_WINDOW_ACTION, default=CONF_WINDOW_TURN_OFF
|
||||
): selector.SelectSelector(
|
||||
selector.SelectSelectorConfig(
|
||||
options=CONF_WINDOW_ACTIONS,
|
||||
translation_key="window_action",
|
||||
mode="dropdown",
|
||||
)
|
||||
),
|
||||
}
|
||||
)
|
||||
|
||||
STEP_CENTRAL_WINDOW_WO_AUTO_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
{
|
||||
vol.Optional(CONF_WINDOW_DELAY, default=30): cv.positive_int,
|
||||
vol.Optional(
|
||||
CONF_WINDOW_ACTION, default=CONF_WINDOW_TURN_OFF
|
||||
): selector.SelectSelector(
|
||||
selector.SelectSelectorConfig(
|
||||
options=CONF_WINDOW_ACTIONS,
|
||||
translation_key="window_action",
|
||||
mode="dropdown",
|
||||
)
|
||||
),
|
||||
}
|
||||
)
|
||||
|
||||
@@ -236,11 +258,19 @@ STEP_CENTRAL_MOTION_DATA_SCHEMA = vol.Schema( # pylint: disable=invalid-name
|
||||
{
|
||||
vol.Optional(CONF_MOTION_DELAY, default=30): cv.positive_int,
|
||||
vol.Optional(CONF_MOTION_OFF_DELAY, default=300): cv.positive_int,
|
||||
vol.Optional(CONF_MOTION_PRESET, default="comfort"): vol.In(
|
||||
CONF_PRESETS_SELECTIONABLE
|
||||
vol.Optional(CONF_MOTION_PRESET, default="comfort"): selector.SelectSelector(
|
||||
selector.SelectSelectorConfig(
|
||||
options=CONF_PRESETS_SELECTIONABLE,
|
||||
translation_key="presets",
|
||||
mode="dropdown",
|
||||
)
|
||||
),
|
||||
vol.Optional(CONF_NO_MOTION_PRESET, default="eco"): vol.In(
|
||||
CONF_PRESETS_SELECTIONABLE
|
||||
vol.Optional(CONF_NO_MOTION_PRESET, default="eco"): selector.SelectSelector(
|
||||
selector.SelectSelectorConfig(
|
||||
options=CONF_PRESETS_SELECTIONABLE,
|
||||
translation_key="presets",
|
||||
mode="dropdown",
|
||||
)
|
||||
),
|
||||
}
|
||||
)
|
||||
|
||||
@@ -132,6 +132,7 @@ CONF_CENTRAL_BOILER_ACTIVATION_SRV = "central_boiler_activation_service"
|
||||
CONF_CENTRAL_BOILER_DEACTIVATION_SRV = "central_boiler_deactivation_service"
|
||||
|
||||
CONF_USED_BY_CENTRAL_BOILER = "used_by_controls_central_boiler"
|
||||
CONF_WINDOW_ACTION = "window_action"
|
||||
|
||||
DEFAULT_SHORT_EMA_PARAMS = {
|
||||
"max_alpha": 0.5,
|
||||
@@ -267,6 +268,7 @@ ALL_CONF = (
|
||||
CONF_USED_BY_CENTRAL_BOILER,
|
||||
CONF_CENTRAL_BOILER_ACTIVATION_SRV,
|
||||
CONF_CENTRAL_BOILER_DEACTIVATION_SRV,
|
||||
CONF_WINDOW_ACTION,
|
||||
]
|
||||
+ CONF_PRESETS_VALUES
|
||||
+ CONF_PRESETS_AWAY_VALUES
|
||||
@@ -302,6 +304,18 @@ CONF_AUTO_FAN_MODES = [
|
||||
CONF_AUTO_FAN_TURBO,
|
||||
]
|
||||
|
||||
CONF_WINDOW_TURN_OFF = "window_turn_off"
|
||||
CONF_WINDOW_FAN_ONLY = "window_fan_only"
|
||||
CONF_WINDOW_FROST_TEMP = "window_frost_temp"
|
||||
CONF_WINDOW_ECO_TEMP = "window_eco_temp"
|
||||
|
||||
CONF_WINDOW_ACTIONS = [
|
||||
CONF_WINDOW_TURN_OFF,
|
||||
CONF_WINDOW_FAN_ONLY,
|
||||
CONF_WINDOW_FROST_TEMP,
|
||||
CONF_WINDOW_ECO_TEMP,
|
||||
]
|
||||
|
||||
SUPPORT_FLAGS = ClimateEntityFeature.TARGET_TEMPERATURE
|
||||
|
||||
SERVICE_SET_PRESENCE = "set_presence"
|
||||
|
||||
@@ -130,7 +130,8 @@
|
||||
"window_auto_open_threshold": "Seuil haut de chute de température pour la détection automatique (en °/heure)",
|
||||
"window_auto_close_threshold": "Seuil bas de chute de température pour la fin de détection automatique (en °/heure)",
|
||||
"window_auto_max_duration": "Durée maximum d'une extinction automatique (en min)",
|
||||
"use_window_central_config": "Utiliser la configuration centrale des ouvertures"
|
||||
"use_window_central_config": "Utiliser la configuration centrale des ouvertures",
|
||||
"window_action": "Action"
|
||||
},
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "Laissez vide si vous n'avez de détecteur et pour utiliser la détection automatique",
|
||||
@@ -138,7 +139,8 @@
|
||||
"window_auto_open_threshold": "Valeur recommandée: entre 3 et 10. Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"window_auto_close_threshold": "Valeur recommandée: 0. Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"window_auto_max_duration": "Valeur recommandée: 60 (1 heure). Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"use_window_central_config": "Cochez pour utiliser la configuration centrale des ouvertures. Décochez et saisissez les attributs pour utiliser une configuration spécifique des ouvertures"
|
||||
"use_window_central_config": "Cochez pour utiliser la configuration centrale des ouvertures. Décochez et saisissez les attributs pour utiliser une configuration spécifique des ouvertures",
|
||||
"window_action": "Action a effectuer si la fenêtre est détectée comme ouverte"
|
||||
}
|
||||
},
|
||||
"motion": {
|
||||
@@ -368,7 +370,8 @@
|
||||
"window_auto_open_threshold": "Seuil haut de chute de température pour la détection automatique (en °/heure)",
|
||||
"window_auto_close_threshold": "Seuil bas de chute de température pour la fin de détection automatique (en °/heure)",
|
||||
"window_auto_max_duration": "Durée maximum d'une extinction automatique (en min)",
|
||||
"use_window_central_config": "Utiliser la configuration centrale des ouvertures"
|
||||
"use_window_central_config": "Utiliser la configuration centrale des ouvertures",
|
||||
"window_action": "Action"
|
||||
},
|
||||
"data_description": {
|
||||
"window_sensor_entity_id": "Laissez vide si vous n'avez de détecteur et pour utiliser la détection automatique",
|
||||
@@ -376,7 +379,8 @@
|
||||
"window_auto_open_threshold": "Valeur recommandée: entre 3 et 10. Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"window_auto_close_threshold": "Valeur recommandée: 0. Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"window_auto_max_duration": "Valeur recommandée: 60 (1 heure). Laissez vide si vous n'utilisez pas la détection automatique",
|
||||
"use_window_central_config": "Cochez pour utiliser la configuration centrale des ouvertures. Décochez et saisissez les attributs pour utiliser une configuration spécifique des ouvertures"
|
||||
"use_window_central_config": "Cochez pour utiliser la configuration centrale des ouvertures. Décochez et saisissez les attributs pour utiliser une configuration spécifique des ouvertures",
|
||||
"window_action": "Action a effectuer si la fenêtre est détectée comme ouverte"
|
||||
}
|
||||
},
|
||||
"motion": {
|
||||
@@ -510,6 +514,22 @@
|
||||
"auto_fan_high": "Forte",
|
||||
"auto_fan_turbo": "Turbo"
|
||||
}
|
||||
},
|
||||
"window_action": {
|
||||
"options": {
|
||||
"window_turn_off": "Eteindre",
|
||||
"window_fan_only": "Ventilateur seul",
|
||||
"window_frost_temp": "Hors gel",
|
||||
"window_eco_temp": "Eco"
|
||||
}
|
||||
},
|
||||
"presets": {
|
||||
"options": {
|
||||
"frost": "Hors-gel",
|
||||
"eco": "Eco",
|
||||
"comfort": "Confort",
|
||||
"boost": "Renforcé (boost)"
|
||||
}
|
||||
}
|
||||
},
|
||||
"entity": {
|
||||
|
||||
Reference in New Issue