Try to fix issue #334 - loop when underlying is late to update
This commit is contained in:
@@ -472,7 +472,7 @@ async def test_multiple_climates_underlying_changes(
|
||||
skip_hass_states_is_state,
|
||||
skip_send_event,
|
||||
): # pylint: disable=unused-argument
|
||||
"""Test that when multiple switch are configured the activation of one underlying
|
||||
"""Test that when multiple climate are configured the activation of one underlying
|
||||
climate activate the others"""
|
||||
|
||||
tz = get_tz(hass) # pylint: disable=invalid-name
|
||||
@@ -541,11 +541,15 @@ async def test_multiple_climates_underlying_changes(
|
||||
assert entity.is_device_active is False # pylint: disable=protected-access
|
||||
|
||||
# Stop heating on one underlying climate
|
||||
# All underlying supposed to be aligned with the hvac_mode now
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.async_control_heating"
|
||||
), patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.set_hvac_mode"
|
||||
) as mock_underlying_set_hvac_mode:
|
||||
) as mock_underlying_set_hvac_mode, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.hvac_mode",
|
||||
HVACMode.HEAT,
|
||||
):
|
||||
# Wait 11 sec so that the event will not be discarded
|
||||
event_timestamp = now + timedelta(seconds=11)
|
||||
await send_climate_change_event(
|
||||
@@ -555,6 +559,7 @@ async def test_multiple_climates_underlying_changes(
|
||||
HVACAction.OFF,
|
||||
HVACAction.HEATING,
|
||||
event_timestamp,
|
||||
underlying_entity_id="switch.mock_climate3",
|
||||
)
|
||||
|
||||
# Should be call for all Switch
|
||||
@@ -577,6 +582,9 @@ async def test_multiple_climates_underlying_changes(
|
||||
# a function but a property
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.hvac_action",
|
||||
HVACAction.IDLE,
|
||||
), patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.hvac_mode",
|
||||
HVACMode.OFF,
|
||||
):
|
||||
# Wait 11 sec so that the event will not be discarded
|
||||
event_timestamp = now + timedelta(seconds=11)
|
||||
@@ -601,6 +609,113 @@ async def test_multiple_climates_underlying_changes(
|
||||
assert entity.is_device_active is False # pylint: disable=protected-access
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
async def test_multiple_climates_underlying_changes_not_aligned(
|
||||
hass: HomeAssistant,
|
||||
skip_hass_states_is_state,
|
||||
skip_send_event,
|
||||
): # pylint: disable=unused-argument
|
||||
"""Test that when multiple climate are configured the activation of one underlying
|
||||
climate don't activate the others if their havc_mode are not aligned"""
|
||||
|
||||
tz = get_tz(hass) # pylint: disable=invalid-name
|
||||
now: datetime = datetime.now(tz=tz)
|
||||
|
||||
entry = MockConfigEntry(
|
||||
domain=DOMAIN,
|
||||
title="TheOver4ClimateMockName",
|
||||
unique_id="uniqueId",
|
||||
data={
|
||||
CONF_NAME: "TheOver4ClimateMockName",
|
||||
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CLIMATE,
|
||||
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
|
||||
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
|
||||
CONF_CYCLE_MIN: 8,
|
||||
CONF_TEMP_MIN: 15,
|
||||
CONF_TEMP_MAX: 30,
|
||||
"eco_temp": 17,
|
||||
"comfort_temp": 18,
|
||||
"boost_temp": 19,
|
||||
CONF_USE_WINDOW_FEATURE: False,
|
||||
CONF_USE_MOTION_FEATURE: False,
|
||||
CONF_USE_POWER_FEATURE: False,
|
||||
CONF_USE_PRESENCE_FEATURE: False,
|
||||
CONF_CLIMATE: "switch.mock_climate1",
|
||||
CONF_CLIMATE_2: "switch.mock_climate2",
|
||||
CONF_CLIMATE_3: "switch.mock_climate3",
|
||||
CONF_CLIMATE_4: "switch.mock_climate4",
|
||||
CONF_MINIMAL_ACTIVATION_DELAY: 30,
|
||||
CONF_SECURITY_DELAY_MIN: 5,
|
||||
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
|
||||
},
|
||||
)
|
||||
|
||||
entity: BaseThermostat = await create_thermostat(
|
||||
hass, entry, "climate.theover4climatemockname"
|
||||
)
|
||||
assert entity
|
||||
assert entity.is_over_climate is True
|
||||
assert entity.nb_underlying_entities == 4
|
||||
|
||||
# start heating, in boost mode. We block the control_heating to avoid running a cycle
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.async_control_heating"
|
||||
), patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.set_hvac_mode"
|
||||
) as mock_underlying_set_hvac_mode:
|
||||
await entity.async_set_hvac_mode(HVACMode.HEAT)
|
||||
await entity.async_set_preset_mode(PRESET_BOOST)
|
||||
|
||||
assert entity.hvac_mode is HVACMode.HEAT
|
||||
assert entity.preset_mode is PRESET_BOOST
|
||||
assert entity.target_temperature == 19
|
||||
assert entity.window_state is STATE_OFF
|
||||
|
||||
event_timestamp = now - timedelta(minutes=4)
|
||||
await send_temperature_change_event(entity, 15, event_timestamp)
|
||||
|
||||
# Should be call for all Switch
|
||||
assert mock_underlying_set_hvac_mode.call_count == 4
|
||||
mock_underlying_set_hvac_mode.assert_has_calls(
|
||||
[
|
||||
call.set_hvac_mode(HVACMode.HEAT),
|
||||
]
|
||||
)
|
||||
|
||||
# Stop heating on one underlying climate
|
||||
# All underlying supposed to be aligned with the hvac_mode now
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.async_control_heating"
|
||||
), patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.set_hvac_mode"
|
||||
) as mock_underlying_set_hvac_mode, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.hvac_mode",
|
||||
HVACMode.COOL,
|
||||
):
|
||||
# Wait 11 sec so that the event will not be discarded
|
||||
event_timestamp = now + timedelta(seconds=11)
|
||||
await send_climate_change_event(
|
||||
entity,
|
||||
HVACMode.OFF,
|
||||
HVACMode.HEAT,
|
||||
HVACAction.OFF,
|
||||
HVACAction.HEATING,
|
||||
event_timestamp,
|
||||
underlying_entity_id="switch.mock_climate3",
|
||||
)
|
||||
|
||||
# Should be call for all Switch
|
||||
assert mock_underlying_set_hvac_mode.call_count == 0
|
||||
# mock_underlying_set_hvac_mode.assert_has_calls(
|
||||
# [
|
||||
# call.set_hvac_mode(HVACMode.OFF),
|
||||
# ]
|
||||
# )
|
||||
# No change
|
||||
assert entity.hvac_mode == HVACMode.HEAT
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
async def test_multiple_switch_power_management(
|
||||
|
||||
Reference in New Issue
Block a user