Add troubleshooting in README

This commit is contained in:
Jean-Marc Collin
2023-11-28 05:40:20 +00:00
parent 475cb67cf8
commit e5076db96c
2 changed files with 117 additions and 2 deletions

View File

@@ -105,7 +105,7 @@ Installations with pilot wire and activation diode benefit from an option which
Some TRV type thermostats are known to be incompatible with the Versatile Thermostat. This is the case for the following valves:
1. Danfoss POPP valves with temperature feedback. It is impossible to turn off this valve and it self-regulates, causing conflicts with the VTherm,
2. Homematic radio” thermostatic valves. They have a duty cycle incompatible with control by the Versatile Thermostat,
2. "Homematic" (and possible Homematic IP) thermostats are known to have problems with Versatile Thermostats because of limitations of the underlying RF protocol. This problem especially occurs when trying to control several Homematic thermostats at once in one Versatile Thermostat instance. In order to reduce duty cycle load, you may e.g. group thermostats with Homematic-specific procedures (e.g. using a wall thermostat) and let Versatile Thermostat only control the wall thermostat directly. Another option is to control only one thermostat and propagate the changes in HVAC mode and temperature by an automation.
3. Thermostat of type Heatzy which doesn't supports the set_temperature command.
4. Thermostats of type Rointe tends to awake alone even if VTherm turns it off. Others functions works fine.
@@ -1017,6 +1017,63 @@ max: 30
If you want to contribute to this please read the [Contribution guidelines](CONTRIBUTING.md)
# Troubleshooting
## Using a Heatzy
The use of a Heatzy is possible provided you use a virtual switch on this model:
```
- platform:template
switches:
bathroom_heating:
unique_id: heating_bathroom
friendly_name: Bathroom heating
value_template: "{{ is_state_attr('climate.bathroom', 'preset_mode', 'comfort') }}"
icon_template: >-
{% if is_state_attr('climate.bathroom', 'preset_mode', 'comfort') %}
mdi:radiator
{% elif is_state_attr('climate.bathroom', 'preset_mode', 'away') %}
mdi:snowflake
{% else %}
mdi:radiator-disabled
{% endif %}
turn on:
service: climate.set_preset_mode
entity_id: climate.bathroom
data:
preset_mode: "comfort"
turn_off:
service: climate.set_preset_mode
entity_id: climate.bathroom
data:
preset_mode: "eco"
```
Thanks to @gael for this example.
## Using a Heatsink with a Pilot Wire
As with the Heatzy above you can use a virtual switch which will change the preset of your radiator depending on the ignition state of the VTherm.
Example :
```
- platform:template
switches:
radiator_soan:
friendly_name: radiator_soan_inv
value_template: "{{ is_state('switch.radiateur_soan', 'off') }}"
turn on:
service: switch.turn_off
data:
entity_id: switch.radiateur_soan
turn_off:
service: switch.turn_on
data:
entity_id: switch.radiateur_soan
icon_template: "{% if is_state('switch.radiateur_soan', 'on') %}mdi:radiator-disabled{% else %}mdi:radiator{% endif %}"
```
## Only the first radiator heats
In `over_switch` mode if several radiators are configured for the same VTherm, switching on will be done sequentially to smooth out consumption peaks as much as possible.
This is completely normal and desired. It is described here: [For a thermostat of type ``thermostat_over_switch```](#for-a-thermostat-of-type-thermostat_over_switch)
***