Feature 234 add central boiler helper (#352)
* Creation of the central boiler config + binary_sensor entity * Fonctional before testu. Miss the service call * Full featured but without testu * Documentation and release. * Add events in README * FIX #341 - when window state change, open_valve_percent should be resend * Issue #343 - disable safety mode for outdoor thermometer * Issue #255 - Specify window action on window open detection * Add en and string translation * central boiler - add entites to fine tune the boiler start * With testu ok * Add testus for valve and climate * Add testus in pipelines * With pip 3 * With more pytest options * Ass coverage tests * Add coverage report in github * Release 5.3.0 --------- Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
@@ -3,9 +3,15 @@
|
||||
import logging
|
||||
import math
|
||||
|
||||
from homeassistant.core import HomeAssistant, callback, Event
|
||||
from homeassistant.core import HomeAssistant, callback, Event, CoreState
|
||||
|
||||
from homeassistant.const import UnitOfTime, UnitOfPower, UnitOfEnergy, PERCENTAGE
|
||||
from homeassistant.const import (
|
||||
UnitOfTime,
|
||||
UnitOfPower,
|
||||
UnitOfEnergy,
|
||||
PERCENTAGE,
|
||||
EVENT_HOMEASSISTANT_START,
|
||||
)
|
||||
|
||||
from homeassistant.components.sensor import (
|
||||
SensorEntity,
|
||||
@@ -16,9 +22,24 @@ from homeassistant.components.sensor import (
|
||||
from homeassistant.config_entries import ConfigEntry
|
||||
|
||||
from homeassistant.helpers.entity_platform import AddEntitiesCallback
|
||||
from homeassistant.helpers.device_registry import DeviceInfo, DeviceEntryType
|
||||
from homeassistant.helpers.entity_component import EntityComponent
|
||||
from homeassistant.helpers.event import async_track_state_change_event
|
||||
|
||||
from homeassistant.components.climate import (
|
||||
ClimateEntity,
|
||||
DOMAIN as CLIMATE_DOMAIN,
|
||||
HVACAction,
|
||||
HVACMode,
|
||||
)
|
||||
|
||||
|
||||
from .base_thermostat import BaseThermostat
|
||||
from .vtherm_api import VersatileThermostatAPI
|
||||
from .commons import VersatileThermostatBaseEntity
|
||||
from .const import (
|
||||
DOMAIN,
|
||||
DEVICE_MANUFACTURER,
|
||||
CONF_NAME,
|
||||
CONF_DEVICE_POWER,
|
||||
CONF_PROP_FUNCTION,
|
||||
@@ -28,6 +49,8 @@ from .const import (
|
||||
CONF_THERMOSTAT_CLIMATE,
|
||||
CONF_THERMOSTAT_TYPE,
|
||||
CONF_THERMOSTAT_CENTRAL_CONFIG,
|
||||
CONF_ADD_CENTRAL_BOILER_CONTROL,
|
||||
overrides,
|
||||
)
|
||||
|
||||
THRESHOLD_WATT_KILO = 100
|
||||
@@ -49,35 +72,43 @@ async def async_setup_entry(
|
||||
name = entry.data.get(CONF_NAME)
|
||||
vt_type = entry.data.get(CONF_THERMOSTAT_TYPE)
|
||||
|
||||
entities = None
|
||||
|
||||
if vt_type == CONF_THERMOSTAT_CENTRAL_CONFIG:
|
||||
return
|
||||
if entry.data.get(CONF_ADD_CENTRAL_BOILER_CONTROL):
|
||||
entities = [
|
||||
NbActiveDeviceForBoilerSensor(hass, unique_id, name, entry.data)
|
||||
]
|
||||
async_add_entities(entities, True)
|
||||
else:
|
||||
entities = [
|
||||
LastTemperatureSensor(hass, unique_id, name, entry.data),
|
||||
LastExtTemperatureSensor(hass, unique_id, name, entry.data),
|
||||
TemperatureSlopeSensor(hass, unique_id, name, entry.data),
|
||||
EMATemperatureSensor(hass, unique_id, name, entry.data),
|
||||
]
|
||||
if entry.data.get(CONF_DEVICE_POWER):
|
||||
entities.append(EnergySensor(hass, unique_id, name, entry.data))
|
||||
if entry.data.get(CONF_THERMOSTAT_TYPE) in [
|
||||
CONF_THERMOSTAT_SWITCH,
|
||||
CONF_THERMOSTAT_VALVE,
|
||||
]:
|
||||
entities.append(MeanPowerSensor(hass, unique_id, name, entry.data))
|
||||
|
||||
entities = [
|
||||
LastTemperatureSensor(hass, unique_id, name, entry.data),
|
||||
LastExtTemperatureSensor(hass, unique_id, name, entry.data),
|
||||
TemperatureSlopeSensor(hass, unique_id, name, entry.data),
|
||||
EMATemperatureSensor(hass, unique_id, name, entry.data),
|
||||
]
|
||||
if entry.data.get(CONF_DEVICE_POWER):
|
||||
entities.append(EnergySensor(hass, unique_id, name, entry.data))
|
||||
if entry.data.get(CONF_THERMOSTAT_TYPE) in [
|
||||
CONF_THERMOSTAT_SWITCH,
|
||||
CONF_THERMOSTAT_VALVE,
|
||||
]:
|
||||
entities.append(MeanPowerSensor(hass, unique_id, name, entry.data))
|
||||
if entry.data.get(CONF_PROP_FUNCTION) == PROPORTIONAL_FUNCTION_TPI:
|
||||
entities.append(OnPercentSensor(hass, unique_id, name, entry.data))
|
||||
entities.append(OnTimeSensor(hass, unique_id, name, entry.data))
|
||||
entities.append(OffTimeSensor(hass, unique_id, name, entry.data))
|
||||
|
||||
if entry.data.get(CONF_PROP_FUNCTION) == PROPORTIONAL_FUNCTION_TPI:
|
||||
entities.append(OnPercentSensor(hass, unique_id, name, entry.data))
|
||||
entities.append(OnTimeSensor(hass, unique_id, name, entry.data))
|
||||
entities.append(OffTimeSensor(hass, unique_id, name, entry.data))
|
||||
if entry.data.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_VALVE:
|
||||
entities.append(ValveOpenPercentSensor(hass, unique_id, name, entry.data))
|
||||
|
||||
if entry.data.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_VALVE:
|
||||
entities.append(ValveOpenPercentSensor(hass, unique_id, name, entry.data))
|
||||
if entry.data.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_CLIMATE:
|
||||
entities.append(
|
||||
RegulatedTemperatureSensor(hass, unique_id, name, entry.data)
|
||||
)
|
||||
|
||||
if entry.data.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_CLIMATE:
|
||||
entities.append(RegulatedTemperatureSensor(hass, unique_id, name, entry.data))
|
||||
|
||||
async_add_entities(entities, True)
|
||||
async_add_entities(entities, True)
|
||||
|
||||
|
||||
class EnergySensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
@@ -597,3 +628,116 @@ class EMATemperatureSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
def suggested_display_precision(self) -> int | None:
|
||||
"""Return the suggested number of decimal digits for display."""
|
||||
return 2
|
||||
|
||||
|
||||
class NbActiveDeviceForBoilerSensor(SensorEntity):
|
||||
"""Representation of the threshold of the number of VTherm
|
||||
which should be active to activate the boiler"""
|
||||
|
||||
def __init__(self, hass: HomeAssistant, unique_id, name, entry_infos) -> None:
|
||||
"""Initialize the energy sensor"""
|
||||
self._hass = hass
|
||||
self._config_id = unique_id
|
||||
self._device_name = entry_infos.get(CONF_NAME)
|
||||
self._attr_name = "Nb device active for boiler"
|
||||
self._attr_unique_id = "nb_device_active_boiler"
|
||||
self._attr_value = self._attr_native_value = None # default value
|
||||
self._entities = []
|
||||
|
||||
@property
|
||||
def icon(self) -> str | None:
|
||||
return "mdi:heat-wave"
|
||||
|
||||
@property
|
||||
def device_info(self) -> DeviceInfo:
|
||||
"""Return the device info."""
|
||||
return DeviceInfo(
|
||||
entry_type=DeviceEntryType.SERVICE,
|
||||
identifiers={(DOMAIN, self._config_id)},
|
||||
name=self._device_name,
|
||||
manufacturer=DEVICE_MANUFACTURER,
|
||||
model=DOMAIN,
|
||||
)
|
||||
|
||||
@property
|
||||
def state_class(self) -> SensorStateClass | None:
|
||||
return SensorStateClass.MEASUREMENT
|
||||
|
||||
@property
|
||||
def suggested_display_precision(self) -> int | None:
|
||||
"""Return the suggested number of decimal digits for display."""
|
||||
return 0
|
||||
|
||||
@overrides
|
||||
async def async_added_to_hass(self) -> None:
|
||||
await super().async_added_to_hass()
|
||||
|
||||
api: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api(self._hass)
|
||||
api.register_nb_device_active_boiler(self)
|
||||
|
||||
@callback
|
||||
async def _async_startup_internal(*_):
|
||||
_LOGGER.debug("%s - Calling async_startup_internal", self)
|
||||
await self.listen_vtherms_entities()
|
||||
|
||||
if self.hass.state == CoreState.running:
|
||||
await _async_startup_internal()
|
||||
else:
|
||||
self.hass.bus.async_listen_once(
|
||||
EVENT_HOMEASSISTANT_START, _async_startup_internal
|
||||
)
|
||||
|
||||
async def listen_vtherms_entities(self):
|
||||
"""Initialize the listening of state change of VTherms"""
|
||||
|
||||
# Listen to all VTherm state change
|
||||
self._entities = []
|
||||
underlying_entities_id = []
|
||||
|
||||
component: EntityComponent[ClimateEntity] = self.hass.data[CLIMATE_DOMAIN]
|
||||
for entity in component.entities:
|
||||
if isinstance(entity, BaseThermostat) and entity.is_used_by_central_boiler:
|
||||
self._entities.append(entity)
|
||||
for under in entity.underlying_entities:
|
||||
underlying_entities_id.append(under.entity_id)
|
||||
if len(underlying_entities_id) > 0:
|
||||
# Arme l'écoute de la première entité
|
||||
listener_cancel = async_track_state_change_event(
|
||||
self._hass,
|
||||
underlying_entities_id,
|
||||
self.calculate_nb_active_devices,
|
||||
)
|
||||
_LOGGER.info(
|
||||
"%s - the underlyings that could controls the central boiler are %s",
|
||||
self,
|
||||
underlying_entities_id,
|
||||
)
|
||||
self.async_on_remove(listener_cancel)
|
||||
else:
|
||||
_LOGGER.debug("%s - no VTherm could controls the central boiler", self)
|
||||
|
||||
await self.calculate_nb_active_devices(None)
|
||||
|
||||
async def calculate_nb_active_devices(self, _):
|
||||
"""Calculate the number of active VTherm that have an
|
||||
influence on central boiler"""
|
||||
|
||||
_LOGGER.debug("%s - calculating the number of active VTherm", self)
|
||||
nb_active = 0
|
||||
for entity in self._entities:
|
||||
_LOGGER.debug(
|
||||
"Examining the hvac_action of %s",
|
||||
entity.name,
|
||||
)
|
||||
if (
|
||||
entity.hvac_mode == HVACMode.HEAT
|
||||
and entity.hvac_action == HVACAction.HEATING
|
||||
):
|
||||
for under in entity.underlying_entities:
|
||||
nb_active += 1 if under.is_device_active else 0
|
||||
|
||||
self._attr_native_value = nb_active
|
||||
self.async_write_ha_state()
|
||||
|
||||
def __str__(self):
|
||||
return f"VersatileThermostat-{self.name}"
|
||||
|
||||
Reference in New Issue