Feature 234 add central boiler helper (#352)
* Creation of the central boiler config + binary_sensor entity * Fonctional before testu. Miss the service call * Full featured but without testu * Documentation and release. * Add events in README * FIX #341 - when window state change, open_valve_percent should be resend * Issue #343 - disable safety mode for outdoor thermometer * Issue #255 - Specify window action on window open detection * Add en and string translation * central boiler - add entites to fine tune the boiler start * With testu ok * Add testus for valve and climate * Add testus in pipelines * With pip 3 * With more pytest options * Ass coverage tests * Add coverage report in github * Release 5.3.0 --------- Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
117
custom_components/versatile_thermostat/number.py
Normal file
117
custom_components/versatile_thermostat/number.py
Normal file
@@ -0,0 +1,117 @@
|
||||
# pylint: disable=unused-argument
|
||||
|
||||
""" Implements the VersatileThermostat select component """
|
||||
import logging
|
||||
|
||||
# from homeassistant.const import EVENT_HOMEASSISTANT_START
|
||||
from homeassistant.core import HomeAssistant, CoreState # , callback
|
||||
|
||||
from homeassistant.components.number import NumberEntity, NumberMode
|
||||
from homeassistant.helpers.device_registry import DeviceInfo, DeviceEntryType
|
||||
from homeassistant.config_entries import ConfigEntry
|
||||
from homeassistant.helpers.restore_state import RestoreEntity
|
||||
from homeassistant.helpers.entity_platform import AddEntitiesCallback
|
||||
|
||||
|
||||
from custom_components.versatile_thermostat.vtherm_api import VersatileThermostatAPI
|
||||
from .const import (
|
||||
DOMAIN,
|
||||
DEVICE_MANUFACTURER,
|
||||
CONF_NAME,
|
||||
CONF_THERMOSTAT_TYPE,
|
||||
CONF_THERMOSTAT_CENTRAL_CONFIG,
|
||||
CONF_ADD_CENTRAL_BOILER_CONTROL,
|
||||
overrides,
|
||||
)
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
|
||||
async def async_setup_entry(
|
||||
hass: HomeAssistant,
|
||||
entry: ConfigEntry,
|
||||
async_add_entities: AddEntitiesCallback,
|
||||
) -> None:
|
||||
"""Set up the VersatileThermostat selects with config flow."""
|
||||
_LOGGER.debug(
|
||||
"Calling async_setup_entry entry=%s, data=%s", entry.entry_id, entry.data
|
||||
)
|
||||
|
||||
unique_id = entry.entry_id
|
||||
name = entry.data.get(CONF_NAME)
|
||||
vt_type = entry.data.get(CONF_THERMOSTAT_TYPE)
|
||||
is_central_boiler = entry.data.get(CONF_ADD_CENTRAL_BOILER_CONTROL)
|
||||
|
||||
if vt_type != CONF_THERMOSTAT_CENTRAL_CONFIG or not is_central_boiler:
|
||||
return
|
||||
|
||||
entities = [
|
||||
ActivateBoilerThresholdNumber(hass, unique_id, name, entry.data),
|
||||
]
|
||||
|
||||
async_add_entities(entities, True)
|
||||
|
||||
|
||||
class ActivateBoilerThresholdNumber(NumberEntity, RestoreEntity):
|
||||
"""Representation of the threshold of the number of VTherm
|
||||
which should be active to activate the boiler"""
|
||||
|
||||
def __init__(self, hass: HomeAssistant, unique_id, name, entry_infos) -> None:
|
||||
"""Initialize the energy sensor"""
|
||||
self._hass = hass
|
||||
self._config_id = unique_id
|
||||
self._device_name = entry_infos.get(CONF_NAME)
|
||||
self._attr_name = "Boiler Activation threshold"
|
||||
self._attr_unique_id = "boiler_activation_threshold"
|
||||
self._attr_value = self._attr_native_value = 1 # default value
|
||||
self._attr_native_min_value = 1
|
||||
self._attr_native_max_value = 9
|
||||
self._attr_step = 1 # default value
|
||||
self._attr_mode = NumberMode.AUTO
|
||||
|
||||
@property
|
||||
def icon(self) -> str | None:
|
||||
if isinstance(self._attr_native_value, int):
|
||||
val = int(self._attr_native_value)
|
||||
return f"mdi:numeric-{val}-box-outline"
|
||||
else:
|
||||
return "mdi:numeric-0-box-outline"
|
||||
|
||||
@property
|
||||
def device_info(self) -> DeviceInfo:
|
||||
"""Return the device info."""
|
||||
return DeviceInfo(
|
||||
entry_type=DeviceEntryType.SERVICE,
|
||||
identifiers={(DOMAIN, self._config_id)},
|
||||
name=self._device_name,
|
||||
manufacturer=DEVICE_MANUFACTURER,
|
||||
model=DOMAIN,
|
||||
)
|
||||
|
||||
@overrides
|
||||
async def async_added_to_hass(self) -> None:
|
||||
await super().async_added_to_hass()
|
||||
|
||||
api: VersatileThermostatAPI = VersatileThermostatAPI.get_vtherm_api(self._hass)
|
||||
api.register_central_boiler_activation_number_threshold(self)
|
||||
|
||||
old_state: CoreState = await self.async_get_last_state()
|
||||
_LOGGER.debug(
|
||||
"%s - Calling async_added_to_hass old_state is %s", self, old_state
|
||||
)
|
||||
if old_state is not None:
|
||||
self._attr_value = self._attr_native_value = int(float(old_state.state))
|
||||
|
||||
@overrides
|
||||
def set_native_value(self, value: float) -> None:
|
||||
"""Change the value"""
|
||||
int_value = int(value)
|
||||
old_value = int(self._attr_native_value)
|
||||
|
||||
if int_value == old_value:
|
||||
return
|
||||
|
||||
self._attr_value = self._attr_native_value = int_value
|
||||
|
||||
def __str__(self):
|
||||
return f"VersatileThermostat-{self.name}"
|
||||
Reference in New Issue