Issue #181 - auto-window for over_climate doesn't work
This commit is contained in:
@@ -1723,8 +1723,8 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
and self.hvac_mode != HVACMode.OFF
|
||||
):
|
||||
if (
|
||||
not self.proportional_algorithm
|
||||
or self.proportional_algorithm.on_percent <= 0.0
|
||||
self.proportional_algorithm
|
||||
and self.proportional_algorithm.on_percent <= 0.0
|
||||
):
|
||||
_LOGGER.info(
|
||||
"%s - Start auto detection of open window slope=%.3f but no heating detected (on_percent<=0). Forget the event",
|
||||
|
||||
@@ -11,7 +11,7 @@ from homeassistant.components.sensor import (
|
||||
SensorEntity,
|
||||
SensorDeviceClass,
|
||||
SensorStateClass,
|
||||
UnitOfTemperature
|
||||
UnitOfTemperature,
|
||||
)
|
||||
from homeassistant.config_entries import ConfigEntry
|
||||
|
||||
@@ -54,7 +54,10 @@ async def async_setup_entry(
|
||||
]
|
||||
if entry.data.get(CONF_DEVICE_POWER):
|
||||
entities.append(EnergySensor(hass, unique_id, name, entry.data))
|
||||
if entry.data.get(CONF_THERMOSTAT_TYPE) in [CONF_THERMOSTAT_SWITCH, CONF_THERMOSTAT_VALVE]:
|
||||
if entry.data.get(CONF_THERMOSTAT_TYPE) in [
|
||||
CONF_THERMOSTAT_SWITCH,
|
||||
CONF_THERMOSTAT_VALVE,
|
||||
]:
|
||||
entities.append(MeanPowerSensor(hass, unique_id, name, entry.data))
|
||||
|
||||
if entry.data.get(CONF_PROP_FUNCTION) == PROPORTIONAL_FUNCTION_TPI:
|
||||
@@ -202,6 +205,9 @@ class OnPercentSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
if self.my_climate and self.my_climate.proportional_algorithm
|
||||
else None
|
||||
)
|
||||
if on_percent is None:
|
||||
return
|
||||
|
||||
if math.isnan(on_percent) or math.isinf(on_percent):
|
||||
raise ValueError(f"Sensor has illegal state {on_percent}")
|
||||
|
||||
@@ -234,6 +240,7 @@ class OnPercentSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
"""Return the suggested number of decimal digits for display."""
|
||||
return 1
|
||||
|
||||
|
||||
class ValveOpenPercentSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
"""Representation of a on percent sensor which exposes the on_percent in a cycle"""
|
||||
|
||||
@@ -295,6 +302,10 @@ class OnTimeSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
if self.my_climate and self.my_climate.proportional_algorithm
|
||||
else None
|
||||
)
|
||||
|
||||
if on_time is None:
|
||||
return
|
||||
|
||||
if math.isnan(on_time) or math.isinf(on_time):
|
||||
raise ValueError(f"Sensor has illegal state {on_time}")
|
||||
|
||||
@@ -340,6 +351,9 @@ class OffTimeSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
if self.my_climate and self.my_climate.proportional_algorithm
|
||||
else None
|
||||
)
|
||||
if off_time is None:
|
||||
return
|
||||
|
||||
if math.isnan(off_time) or math.isinf(off_time):
|
||||
raise ValueError(f"Sensor has illegal state {off_time}")
|
||||
|
||||
@@ -476,6 +490,7 @@ class TemperatureSlopeSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
"""Return the suggested number of decimal digits for display."""
|
||||
return 2
|
||||
|
||||
|
||||
class RegulatedTemperatureSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
"""Representation of a Energy sensor which exposes the energy"""
|
||||
|
||||
@@ -493,7 +508,9 @@ class RegulatedTemperatureSensor(VersatileThermostatBaseEntity, SensorEntity):
|
||||
if math.isnan(self.my_climate.regulated_target_temp) or math.isinf(
|
||||
self.my_climate.regulated_target_temp
|
||||
):
|
||||
raise ValueError(f"Sensor has illegal state {self.my_climate.regulated_target_temp}")
|
||||
raise ValueError(
|
||||
f"Sensor has illegal state {self.my_climate.regulated_target_temp}"
|
||||
)
|
||||
|
||||
old_state = self._attr_native_value
|
||||
self._attr_native_value = round(
|
||||
|
||||
Reference in New Issue