Sonoff TRVZB workaround to the 'hvac_action' always Idle issue
Fixes #902
This commit is contained in:
@@ -968,10 +968,10 @@ class UnderlyingValve(UnderlyingEntity):
|
||||
# This could happens in unit test if input_number domain is not yet loaded
|
||||
# raise err
|
||||
|
||||
async def send_percent_open(self):
|
||||
async def send_percent_open(self, fixed_value: float = None):
|
||||
"""Send the percent open to the underlying valve"""
|
||||
# This may fails if called after shutdown
|
||||
return await self._send_value_to_number(self._entity_id, self._percent_open)
|
||||
return await self._send_value_to_number(self._entity_id, self._percent_open if fixed_value is None else fixed_value)
|
||||
|
||||
async def turn_off(self):
|
||||
"""Turn heater toggleable device off."""
|
||||
@@ -1108,6 +1108,14 @@ class UnderlyingValveRegulation(UnderlyingValve):
|
||||
self._max_offset_calibration: float = None
|
||||
self._min_opening_degree: int = min_opening_degree
|
||||
|
||||
def _normalize_opening_closing_degree(self, opening: float) -> float:
|
||||
"""Issue #902 - Normalize the opening and closing degree"""
|
||||
|
||||
new_opening = max(opening - 1, 0)
|
||||
new_closing = max(self._max_opening_degree - 1 - new_opening, 0)
|
||||
|
||||
return new_opening, new_closing
|
||||
|
||||
async def send_percent_open(self):
|
||||
"""Send the percent open to the underlying valve"""
|
||||
if not self._is_min_max_initialized:
|
||||
@@ -1150,17 +1158,16 @@ class UnderlyingValveRegulation(UnderlyingValve):
|
||||
else:
|
||||
self._percent_open = 0
|
||||
|
||||
# Send opening_degree
|
||||
await super().send_percent_open()
|
||||
|
||||
# Send closing_degree if set
|
||||
closing_degree = None
|
||||
opening_degree, closing_degree = self._normalize_opening_closing_degree(self._percent_open)
|
||||
# We should not change the _percent_open because it is used to check if value has bchanged
|
||||
# self._percent_open = opening_degree
|
||||
|
||||
# Send opening_degree
|
||||
await super().send_percent_open(opening_degree)
|
||||
|
||||
if self.have_closing_degree_entity:
|
||||
await self._send_value_to_number(
|
||||
self._closing_degree_entity_id,
|
||||
# Patch to fix the hvac_action always Idle issue (issue #902)
|
||||
closing_degree := max(self._max_opening_degree - 1 - self._percent_open, 0),
|
||||
)
|
||||
await self._send_value_to_number(self._closing_degree_entity_id, closing_degree)
|
||||
|
||||
# send offset_calibration to the difference between target temp and local temp
|
||||
offset = None
|
||||
|
||||