Issue 585 add auto start/stop feature (#594)
* Migrate to HA 2024.10.4 * Auto start/stop alog and testu + ConfigFlow * With config flow ok * Change algo * All is fine * Add change_preset test * + comment * FIX too much start/stop * Change algo to take slop into account * Allow calculation even if slope is None * With enable + tests + hysteresis in calculation * Add hvac_off_reason and test with window interaction * Fix some tests * Restore saved_state * Release --------- Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
@@ -62,72 +62,7 @@ from homeassistant.const import (
|
||||
STATE_NOT_HOME,
|
||||
)
|
||||
|
||||
from .const import (
|
||||
DOMAIN,
|
||||
DEVICE_MANUFACTURER,
|
||||
CONF_POWER_SENSOR,
|
||||
CONF_TEMP_SENSOR,
|
||||
CONF_LAST_SEEN_TEMP_SENSOR,
|
||||
CONF_EXTERNAL_TEMP_SENSOR,
|
||||
CONF_MAX_POWER_SENSOR,
|
||||
CONF_WINDOW_SENSOR,
|
||||
CONF_WINDOW_DELAY,
|
||||
CONF_WINDOW_AUTO_CLOSE_THRESHOLD,
|
||||
CONF_WINDOW_AUTO_OPEN_THRESHOLD,
|
||||
CONF_WINDOW_AUTO_MAX_DURATION,
|
||||
CONF_MOTION_SENSOR,
|
||||
CONF_MOTION_DELAY,
|
||||
CONF_MOTION_OFF_DELAY,
|
||||
CONF_MOTION_PRESET,
|
||||
CONF_NO_MOTION_PRESET,
|
||||
CONF_DEVICE_POWER,
|
||||
CONF_PRESETS,
|
||||
# CONF_PRESETS_AWAY,
|
||||
# CONF_PRESETS_WITH_AC,
|
||||
# CONF_PRESETS_AWAY_WITH_AC,
|
||||
CONF_CYCLE_MIN,
|
||||
CONF_PROP_FUNCTION,
|
||||
CONF_TPI_COEF_INT,
|
||||
CONF_TPI_COEF_EXT,
|
||||
CONF_PRESENCE_SENSOR,
|
||||
CONF_PRESET_POWER,
|
||||
SUPPORT_FLAGS,
|
||||
PRESET_FROST_PROTECTION,
|
||||
PRESET_POWER,
|
||||
PRESET_SECURITY,
|
||||
PROPORTIONAL_FUNCTION_TPI,
|
||||
PRESET_AWAY_SUFFIX,
|
||||
CONF_SECURITY_DELAY_MIN,
|
||||
CONF_SECURITY_MIN_ON_PERCENT,
|
||||
CONF_SECURITY_DEFAULT_ON_PERCENT,
|
||||
DEFAULT_SECURITY_MIN_ON_PERCENT,
|
||||
DEFAULT_SECURITY_DEFAULT_ON_PERCENT,
|
||||
CONF_MINIMAL_ACTIVATION_DELAY,
|
||||
CONF_USE_MAIN_CENTRAL_CONFIG,
|
||||
CONF_USE_TPI_CENTRAL_CONFIG,
|
||||
CONF_USE_PRESETS_CENTRAL_CONFIG,
|
||||
CONF_USE_WINDOW_CENTRAL_CONFIG,
|
||||
CONF_USE_MOTION_CENTRAL_CONFIG,
|
||||
CONF_USE_POWER_CENTRAL_CONFIG,
|
||||
CONF_USE_PRESENCE_CENTRAL_CONFIG,
|
||||
CONF_USE_ADVANCED_CENTRAL_CONFIG,
|
||||
CONF_USE_PRESENCE_FEATURE,
|
||||
CONF_TEMP_MAX,
|
||||
CONF_TEMP_MIN,
|
||||
HIDDEN_PRESETS,
|
||||
CONF_AC_MODE,
|
||||
EventType,
|
||||
ATTR_MEAN_POWER_CYCLE,
|
||||
ATTR_TOTAL_ENERGY,
|
||||
PRESET_AC_SUFFIX,
|
||||
DEFAULT_SHORT_EMA_PARAMS,
|
||||
CENTRAL_MODE_AUTO,
|
||||
CENTRAL_MODE_STOPPED,
|
||||
CENTRAL_MODE_HEAT_ONLY,
|
||||
CENTRAL_MODE_COOL_ONLY,
|
||||
CENTRAL_MODE_FROST_PROTECTION,
|
||||
send_vtherm_event,
|
||||
)
|
||||
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
|
||||
|
||||
from .config_schema import * # pylint: disable=wildcard-import, unused-wildcard-import
|
||||
|
||||
@@ -199,6 +134,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"is_device_active",
|
||||
"target_temperature_step",
|
||||
"is_used_by_central_boiler",
|
||||
"temperature_slope"
|
||||
}
|
||||
)
|
||||
)
|
||||
@@ -303,6 +239,8 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
|
||||
self._use_central_config_temperature = False
|
||||
|
||||
self._hvac_off_reason: HVAC_OFF_REASONS | None = None
|
||||
|
||||
self.post_init(entry_infos)
|
||||
|
||||
def clean_central_config_doublon(
|
||||
@@ -848,18 +786,24 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
else:
|
||||
self._attr_preset_mode = PRESET_NONE
|
||||
|
||||
# Restore old hvac_off_reason
|
||||
self._hvac_off_reason = old_state.attributes.get(HVAC_OFF_REASON_NAME, None)
|
||||
|
||||
if old_state.state in [
|
||||
HVACMode.OFF,
|
||||
HVACMode.HEAT,
|
||||
HVACMode.COOL,
|
||||
]:
|
||||
self._hvac_mode = old_state.state
|
||||
else:
|
||||
if not self._hvac_mode:
|
||||
self._hvac_mode = HVACMode.OFF
|
||||
|
||||
# restpre also saved info so that window detection will work
|
||||
self._saved_hvac_mode = old_state.attributes.get("saved_hvac_mode", None)
|
||||
self._saved_preset_mode = old_state.attributes.get(
|
||||
"saved_preset_mode", None
|
||||
)
|
||||
|
||||
old_total_energy = old_state.attributes.get(ATTR_TOTAL_ENERGY)
|
||||
self._total_energy = old_total_energy if old_total_energy else 0
|
||||
self._total_energy = old_total_energy if old_total_energy is not None else 0
|
||||
|
||||
self.restore_specific_previous_state(old_state)
|
||||
else:
|
||||
@@ -874,12 +818,14 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
)
|
||||
self._total_energy = 0
|
||||
|
||||
self._saved_target_temp = self._target_temp
|
||||
|
||||
# Set default state to off
|
||||
if not self._hvac_mode:
|
||||
self._hvac_mode = HVACMode.OFF
|
||||
|
||||
if not self.is_on and self.hvac_off_reason is None:
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_MANUAL)
|
||||
|
||||
self._saved_target_temp = self._target_temp
|
||||
|
||||
self.send_event(EventType.PRESET_EVENT, {"preset": self._attr_preset_mode})
|
||||
self.send_event(EventType.HVAC_MODE_EVENT, {"hvac_mode": self._hvac_mode})
|
||||
|
||||
@@ -987,16 +933,6 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
@property
|
||||
def hvac_mode(self) -> HVACMode | None:
|
||||
"""Return current operation."""
|
||||
# Issue #114 - returns my current hvac_mode and not the underlying hvac_mode which could be different
|
||||
# delta will be managed by climate_state_change event.
|
||||
# if self.is_over_climate:
|
||||
# if one not OFF -> return it
|
||||
# else OFF
|
||||
# for under in self._underlyings:
|
||||
# if (mode := under.hvac_mode) not in [HVACMode.OFF]
|
||||
# return mode
|
||||
# return HVACMode.OFF
|
||||
|
||||
return self._hvac_mode
|
||||
|
||||
@property
|
||||
@@ -1193,6 +1129,13 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"""True if this VTHerm uses the central configuration temperature"""
|
||||
return self._use_central_config_temperature
|
||||
|
||||
@property
|
||||
def hvac_off_reason(self) -> HVAC_OFF_REASONS:
|
||||
"""Returns the reason of the last switch to HVAC_OFF
|
||||
This is useful for features that turns off the VTherm like
|
||||
window detection or auto-start-stop"""
|
||||
return self._hvac_off_reason
|
||||
|
||||
def underlying_entity_id(self, index=0) -> str | None:
|
||||
"""The climate_entity_id. Added for retrocompatibility reason"""
|
||||
if index < self.nb_underlying_entities:
|
||||
@@ -1255,9 +1198,11 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
|
||||
# Ensure we update the current operation after changing the mode
|
||||
self.reset_last_temperature_time()
|
||||
|
||||
self.reset_last_change_time()
|
||||
|
||||
if self._hvac_mode != HVACMode.OFF:
|
||||
self.set_hvac_off_reason(None)
|
||||
|
||||
self.update_custom_attributes()
|
||||
self.async_write_ha_state()
|
||||
self.send_event(EventType.HVAC_MODE_EVENT, {"hvac_mode": self._hvac_mode})
|
||||
@@ -1760,6 +1705,19 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
for under in self._underlyings:
|
||||
await under.check_initial_state(self._hvac_mode)
|
||||
|
||||
# Prevent from starting a VTherm if window is open
|
||||
if (
|
||||
self.is_window_auto_enabled
|
||||
and self._window_sensor_entity_id is not None
|
||||
and self._hass.states.is_state(self._window_sensor_entity_id, STATE_ON)
|
||||
and self.is_on
|
||||
and self.window_action == CONF_WINDOW_TURN_OFF
|
||||
):
|
||||
_LOGGER.info("%s - the window is open. Prevent starting the VTherm")
|
||||
self._window_auto_state = True
|
||||
self.save_hvac_mode()
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
|
||||
# Starts the initial control loop (don't wait for an update of temperature)
|
||||
await self.async_control_heating(force=True)
|
||||
|
||||
@@ -2096,6 +2054,10 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
self._hvac_mode,
|
||||
)
|
||||
|
||||
def set_hvac_off_reason(self, hvac_off_reason: HVAC_OFF_REASONS):
|
||||
"""Set the reason of hvac_off"""
|
||||
self._hvac_off_reason = hvac_off_reason
|
||||
|
||||
async def restore_hvac_mode(self, need_control_heating=False):
|
||||
"""Restore a previous hvac_mod"""
|
||||
await self.async_set_hvac_mode(self._saved_hvac_mode, need_control_heating)
|
||||
@@ -2227,13 +2189,16 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
if self.window_state is not STATE_ON and not first_init:
|
||||
await self.restore_hvac_mode()
|
||||
await self.restore_preset_mode()
|
||||
|
||||
elif self.window_state is STATE_ON and self.hvac_mode == HVACMode.OFF:
|
||||
# do not restore but mark the reason of off with window detection
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_WINDOW_DETECTION)
|
||||
return
|
||||
|
||||
if old_central_mode == CENTRAL_MODE_AUTO and self.window_state is not STATE_ON:
|
||||
save_all()
|
||||
|
||||
if new_central_mode == CENTRAL_MODE_STOPPED:
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_MANUAL)
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
return
|
||||
|
||||
@@ -2241,6 +2206,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
if HVACMode.COOL in self.hvac_modes:
|
||||
await self.async_set_hvac_mode(HVACMode.COOL)
|
||||
else:
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_MANUAL)
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
return
|
||||
|
||||
@@ -2248,6 +2214,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
if HVACMode.HEAT in self.hvac_modes:
|
||||
await self.async_set_hvac_mode(HVACMode.HEAT)
|
||||
else:
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_MANUAL)
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
return
|
||||
|
||||
@@ -2261,6 +2228,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
PRESET_FROST_PROTECTION, overwrite_saved_preset=False
|
||||
)
|
||||
else:
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_MANUAL)
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
return
|
||||
|
||||
@@ -2440,17 +2408,27 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"""Change the window detection state.
|
||||
new_state is on if an open window have been detected or off else
|
||||
"""
|
||||
if not new_state:
|
||||
if new_state is False:
|
||||
_LOGGER.info(
|
||||
"%s - Window is closed. Restoring hvac_mode '%s' if central_mode is not STOPPED",
|
||||
"%s - Window is closed. Restoring hvac_mode '%s' if stopped by window detection or temperature %s",
|
||||
self,
|
||||
self._saved_hvac_mode,
|
||||
self._saved_target_temp,
|
||||
)
|
||||
if self._window_action in [CONF_WINDOW_FROST_TEMP, CONF_WINDOW_ECO_TEMP]:
|
||||
await self._async_internal_set_temperature(self._saved_target_temp)
|
||||
|
||||
# default to TURN_OFF
|
||||
elif self._window_action in [CONF_WINDOW_TURN_OFF, CONF_WINDOW_FAN_ONLY]:
|
||||
elif self._window_action in [CONF_WINDOW_TURN_OFF]:
|
||||
if (
|
||||
self.last_central_mode != CENTRAL_MODE_STOPPED
|
||||
and self.hvac_off_reason == HVAC_OFF_REASON_WINDOW_DETECTION
|
||||
):
|
||||
self.set_hvac_off_reason(None)
|
||||
await self.restore_hvac_mode(True)
|
||||
elif self._window_action in [CONF_WINDOW_FAN_ONLY]:
|
||||
if self.last_central_mode != CENTRAL_MODE_STOPPED:
|
||||
self.set_hvac_off_reason(None)
|
||||
await self.restore_hvac_mode(True)
|
||||
else:
|
||||
_LOGGER.error(
|
||||
@@ -2462,6 +2440,12 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
_LOGGER.info(
|
||||
"%s - Window is open. Set hvac_mode to '%s'", self, HVACMode.OFF
|
||||
)
|
||||
if self._window_action == CONF_WINDOW_TURN_OFF and not self.is_on:
|
||||
_LOGGER.debug(
|
||||
"%s is already off. Forget turning off VTherm due to window detection"
|
||||
)
|
||||
return
|
||||
|
||||
if self.last_central_mode in [CENTRAL_MODE_AUTO, None]:
|
||||
if self._window_action in [CONF_WINDOW_TURN_OFF, CONF_WINDOW_FAN_ONLY]:
|
||||
self.save_hvac_mode()
|
||||
@@ -2491,6 +2475,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
self.find_preset_temp(PRESET_ECO)
|
||||
)
|
||||
else: # default is to turn_off
|
||||
self.set_hvac_off_reason(HVAC_OFF_REASON_WINDOW_DETECTION)
|
||||
await self.async_set_hvac_mode(HVACMode.OFF)
|
||||
|
||||
async def async_control_heating(self, force=False, _=None) -> bool:
|
||||
@@ -2633,6 +2618,8 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
||||
"is_device_active": self.is_device_active,
|
||||
"ema_temp": self._ema_temp,
|
||||
"is_used_by_central_boiler": self.is_used_by_central_boiler,
|
||||
"temperature_slope": round(self.last_temperature_slope or 0, 3),
|
||||
"hvac_off_reason": self.hvac_off_reason,
|
||||
}
|
||||
|
||||