Fix frost_protection for Nodon
This commit is contained in:
@@ -71,12 +71,12 @@ To customize the commands, click on `Add` at the bottom of the page for both the
|
||||
Then, specify the on and off commands using the format `command[/attribute[:value]]`.
|
||||
The available commands depend on the type of underlying device:
|
||||
|
||||
| Underlying Device Type | Possible On Commands | Possible Off Commands | Applies To |
|
||||
| --------------------------- | ------------------------------------- | ----------------------------------- | ----------------------------- |
|
||||
| `switch` or `input_boolean` | `turn_on` | `turn_off` | All switches |
|
||||
| `select` or `input_select` | `select_option/option:comfort` | `set_option/option:frost` | Nodon SIN-4-FP-21 and similar |
|
||||
| `climate` (hvac_mode) | `set_hvac_mode/hvac_mode:heat` | `set_hvac_mode/hvac_mode:off` | eCosy (via Tuya Local) |
|
||||
| `climate` (preset) | `set_preset_mode/preset_mode:comfort` | `set_preset_mode/preset_mode:frost` | Heatzy |
|
||||
| Underlying Device Type | Possible On Commands | Possible Off Commands | Applies To |
|
||||
| --------------------------- | ------------------------------------- | ---------------------------------------------- | ----------------------------- |
|
||||
| `switch` or `input_boolean` | `turn_on` | `turn_off` | All switches |
|
||||
| `select` or `input_select` | `select_option/option:comfort` | `set_option/option:frost_protection` | Nodon SIN-4-FP-21 and similar |
|
||||
| `climate` (hvac_mode) | `set_hvac_mode/hvac_mode:heat` | `set_hvac_mode/hvac_mode:off` | eCosy (via Tuya Local) |
|
||||
| `climate` (preset) | `set_preset_mode/preset_mode:comfort` | `set_preset_mode/preset_mode:frost_protection` | Heatzy |
|
||||
|
||||
Of course, these examples can be adapted to your specific case.
|
||||
|
||||
|
||||
@@ -69,12 +69,12 @@ Pour personnaliser les commande, cliquez sur `Ajouter` en bas de page sur les co
|
||||
et donner la commande d'allumage et d'exinction avec le format `commande[/attribut[:valeur]]`.
|
||||
Les commandes possibles dépendent du type de sous-jacents :
|
||||
|
||||
| type de sous-jacent | commandes d'allumage possibles | commandes d'extinction possibles | S'applique à |
|
||||
| --------------------------- | ------------------------------------- | ----------------------------------- | ------------------------------ |
|
||||
| `switch` ou `input_boolean` | `turn_on` | `turn_off` | tous les switchs |
|
||||
| `select` ou `input_select` | `select_option/option:comfort` | `set_option/option:frost` | Nodon SIN-4-FP-21 et assimilés |
|
||||
| `climate` (hvac_mode) | `set_hvac_mode/hvac_mode:heat` | `set_hvac_mode/hvac_mode:off` | eCosy (via Tuya Local) |
|
||||
| `climate` (preset) | `set_preset_mode/preset_mode:comfort` | `set_preset_mode/preset_mode:frost` | Heatzy |
|
||||
| type de sous-jacent | commandes d'allumage possibles | commandes d'extinction possibles | S'applique à |
|
||||
| --------------------------- | ------------------------------------- | ---------------------------------------------- | ------------------------------ |
|
||||
| `switch` ou `input_boolean` | `turn_on` | `turn_off` | tous les switchs |
|
||||
| `select` ou `input_select` | `select_option/option:comfort` | `set_option/option:frost_protection` | Nodon SIN-4-FP-21 et assimilés |
|
||||
| `climate` (hvac_mode) | `set_hvac_mode/hvac_mode:heat` | `set_hvac_mode/hvac_mode:off` | eCosy (via Tuya Local) |
|
||||
| `climate` (preset) | `set_preset_mode/preset_mode:comfort` | `set_preset_mode/preset_mode:frost_protection` | Heatzy |
|
||||
|
||||
Evidemment, tous ces exemples peuvent être adaptés à votre cas.
|
||||
|
||||
|
||||