FIX anto_fan rule for Cooling mode.
This commit is contained in:
@@ -9,7 +9,11 @@ from homeassistant.helpers.event import (
|
||||
async_track_time_interval,
|
||||
)
|
||||
|
||||
from homeassistant.components.climate import HVACAction, HVACMode, ClimateEntityFeature
|
||||
from homeassistant.components.climate import (
|
||||
HVACAction,
|
||||
HVACMode,
|
||||
ClimateEntityFeature,
|
||||
)
|
||||
|
||||
from .commons import NowClass, round_to_nearest
|
||||
from .base_thermostat import BaseThermostat
|
||||
@@ -194,6 +198,16 @@ class ThermostatOverClimate(BaseThermostat):
|
||||
should_activate_auto_fan = (
|
||||
dtemp >= AUTO_FAN_DTEMP_THRESHOLD or dtemp <= -AUTO_FAN_DTEMP_THRESHOLD
|
||||
)
|
||||
|
||||
# deal with ac / non ac mode
|
||||
hvac_mode = self.hvac_mode
|
||||
if (
|
||||
(hvac_mode == HVACMode.COOL and dtemp > 0)
|
||||
or (hvac_mode == HVACMode.HEAT and dtemp < 0)
|
||||
or (hvac_mode == HVACMode.OFF)
|
||||
):
|
||||
should_activate_auto_fan = False
|
||||
|
||||
if should_activate_auto_fan and self.fan_mode != self._auto_activated_fan_mode:
|
||||
_LOGGER.info(
|
||||
"%s - Activate the auto fan mode with %s because delta temp is %.2f",
|
||||
|
||||