Make the temperature preset as persistent entities / redesign of the configuration menu (#409)

* HA 2024.2.b4

* Add temp entities initialization

* Python12 env rebuild

* Init temperature number for central configuration + testus ok

* With calculation of VTherm temp entities + test ok

* FIX some testus. Some others are still KO

* Beers

* Update central config Number temp entity

* Many but not all testus ok

* All testus ok

* With central config temp change ok

* Cleaning and fixing Issues

* Validation tests ok

* With new menu. Testus KO

* All developped and tests ok

* Fix central_config menu

* Documentation and release

* Fix testus KO

* Add log into migration for testu

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
Jean-Marc Collin
2024-03-16 18:10:13 +01:00
committed by GitHub
parent 12025c0610
commit 9fb9d89f17
49 changed files with 3719 additions and 1177 deletions

View File

@@ -4,23 +4,13 @@
from unittest.mock import patch # , call
# from datetime import datetime # , timedelta
from homeassistant import data_entry_flow
from homeassistant.data_entry_flow import FlowResultType
from homeassistant.core import HomeAssistant
# from homeassistant.components.climate import HVACAction, HVACMode
from homeassistant.config_entries import ConfigEntryState, SOURCE_USER
# from homeassistant.helpers.entity_component import EntityComponent
# from homeassistant.components.climate import ClimateEntity, DOMAIN as CLIMATE_DOMAIN
from homeassistant.config_entries import SOURCE_USER
from pytest_homeassistant_custom_component.common import MockConfigEntry
# from custom_components.versatile_thermostat.base_thermostat import BaseThermostat
from custom_components.versatile_thermostat.thermostat_climate import (
ThermostatOverClimate,
)
from custom_components.versatile_thermostat.thermostat_switch import (
ThermostatOverSwitch,
)
@@ -31,8 +21,8 @@ from .commons import * # pylint: disable=wildcard-import, unused-wildcard-impor
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
# @pytest.mark.parametrize("expected_lingering_tasks", [True])
# @pytest.mark.parametrize("expected_lingering_timers", [True])
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_add_a_central_config(hass: HomeAssistant, skip_hass_states_is_state):
"""Tests the clean_central_config_doubon of base_thermostat"""
central_config_entry = MockConfigEntry(
@@ -76,17 +66,20 @@ async def test_add_a_central_config(hass: HomeAssistant, skip_hass_states_is_sta
CONF_SECURITY_DELAY_MIN: 61,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.2,
CONF_ADD_CENTRAL_BOILER_CONTROL: False,
CONF_USE_CENTRAL_BOILER_FEATURE: False,
},
)
central_config_entry.add_to_hass(hass)
await hass.config_entries.async_setup(central_config_entry.entry_id)
assert central_config_entry.state is ConfigEntryState.LOADED
entity: ThermostatOverClimate = search_entity(
hass, "climate.thecentralconfigmockname", "climate"
entity = await create_thermostat(
hass, central_config_entry, "climate.thecentralconfigmockname"
)
# central_config_entry.add_to_hass(hass)
# await hass.config_entries.async_setup(central_config_entry.entry_id)
# assert central_config_entry.state is ConfigEntryState.LOADED
#
# entity: ThermostatOverClimate = search_entity(
# hass, "climate.thecentralconfigmockname", "climate"
# )
assert entity is None
@@ -101,8 +94,8 @@ async def test_add_a_central_config(hass: HomeAssistant, skip_hass_states_is_sta
assert api.nb_active_device_for_boiler_entity is None
assert api.nb_active_device_for_boiler is None
assert api.nb_active_device_for_boiler_threshold_entity is None
assert api.nb_active_device_for_boiler_threshold is None
assert api.nb_active_device_for_boiler_threshold_entity is not None
assert api.nb_active_device_for_boiler_threshold == 1 # the default value
# @pytest.mark.parametrize("expected_lingering_tasks", [True])
@@ -185,8 +178,8 @@ async def test_minimal_over_switch_wo_central_config(
entity.remove_thermostat()
# @pytest.mark.parametrize("expected_lingering_tasks", [True])
# @pytest.mark.parametrize("expected_lingering_timers", [True])
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_full_over_switch_wo_central_config(
hass: HomeAssistant, skip_hass_states_is_state, init_vtherm_api
):
@@ -303,8 +296,8 @@ async def test_full_over_switch_wo_central_config(
entity.remove_thermostat()
# @pytest.mark.parametrize("expected_lingering_tasks", [True])
# @pytest.mark.parametrize("expected_lingering_timers", [True])
@pytest.mark.parametrize("expected_lingering_tasks", [True])
@pytest.mark.parametrize("expected_lingering_timers", [True])
async def test_full_over_switch_with_central_config(
hass: HomeAssistant, skip_hass_states_is_state, init_central_config
):
@@ -437,7 +430,13 @@ async def test_over_switch_with_central_config_but_no_central_config(
},
)
assert result["type"] == data_entry_flow.RESULT_TYPE_FORM
assert result["type"] == FlowResultType.MENU
assert result["step_id"] == "menu"
result = await hass.config_entries.flow.async_configure(
result["flow_id"], user_input={"next_step_id": "main"}
)
assert result["type"] == FlowResultType.FORM
assert result["step_id"] == "main"
assert result["errors"] == {}
@@ -448,15 +447,71 @@ async def test_over_switch_with_central_config_but_no_central_config(
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
CONF_CYCLE_MIN: 5,
CONF_DEVICE_POWER: 1,
CONF_USE_WINDOW_FEATURE: True,
CONF_USE_MOTION_FEATURE: False,
CONF_USE_POWER_FEATURE: False,
CONF_USE_PRESENCE_FEATURE: False,
CONF_USE_MAIN_CENTRAL_CONFIG: True,
},
)
assert result["type"] == data_entry_flow.RESULT_TYPE_FORM
assert result["type"] == FlowResultType.FORM
# in case of error we stays in main
assert result["step_id"] == "main"
assert result["errors"] == {"use_main_central_config": "no_central_config"}
async def test_migration_of_central_config(
hass: HomeAssistant,
skip_hass_states_is_state,
):
"""Tests the clean_central_config_doubon of base_thermostat"""
central_config_entry = MockConfigEntry(
version=CONFIG_VERSION,
# An old minor version
minor_version=1,
domain=DOMAIN,
title="TheCentralConfigMockName",
unique_id="centralConfigUniqueId",
data={
CONF_NAME: CENTRAL_CONFIG_NAME,
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_CENTRAL_CONFIG,
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
CONF_TEMP_MIN: 15,
CONF_TEMP_MAX: 30,
CONF_STEP_TEMPERATURE: 0.1,
CONF_TPI_COEF_INT: 0.5,
CONF_TPI_COEF_EXT: 0.02,
CONF_MINIMAL_ACTIVATION_DELAY: 11,
CONF_SECURITY_DELAY_MIN: 61,
CONF_SECURITY_MIN_ON_PERCENT: 0.5,
CONF_SECURITY_DEFAULT_ON_PERCENT: 0.2,
# The old central_boiler parameter
"add_central_boiler_control": True,
CONF_CENTRAL_BOILER_ACTIVATION_SRV: "switch.pompe_chaudiere/switch.turn_on",
CONF_CENTRAL_BOILER_DEACTIVATION_SRV: "switch.pompe_chaudiere/switch.turn_off",
},
)
central_config_entry.add_to_hass(hass)
await hass.config_entries.async_setup(central_config_entry.entry_id)
assert central_config_entry.state is ConfigEntryState.LOADED
entity: ThermostatOverClimate = search_entity(
hass, "climate.thecentralconfigmockname", "climate"
)
assert entity is None
assert count_entities(hass, "climate.thecentralconfigmockname", "climate") == 0
# Test that VTherm API find the CentralConfig
api = VersatileThermostatAPI.get_vtherm_api(hass)
central_configuration = api.find_central_configuration()
assert central_configuration is not None
assert central_config_entry.data.get(CONF_USE_CENTRAL_BOILER_FEATURE) is True
# Test that VTherm API have any central boiler entities
# It should have been migrated and initialized
assert api.nb_active_device_for_boiler_entity is not None
assert api.nb_active_device_for_boiler == 0
assert api.nb_active_device_for_boiler_threshold_entity is not None
assert api.nb_active_device_for_boiler_threshold is 1 # the default value is 1