* Refactor Presence Feature * Add PresenceFeatureManager ok * Python 3.13 * Fix presence test * Refactor power feature * Add Motion manager. All tests ok * Tests ok. But tests are not complete * All tests Window Feature Manager ok. * All windows tests ok * Fix all testus with feature_window_manager ok * Add test_auto_start_stop feature manager. All tests ok * Add safety feature_safety_manager Rename config attribute from security_ to safety_ * Documentation and release * Add safety manager direct tests * Typo --------- Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
@@ -18,9 +18,9 @@
|
||||
## Battery-Powered Temperature Sensor
|
||||
These sensors are often sluggish and do not always send temperature readings when the temperature is stable. Therefore, the settings should be loose to avoid false positives.
|
||||
|
||||
- security_delay_min: 60 minutes (because these sensors are sluggish)
|
||||
- security_min_on_percent: 0.7 (70% - the system goes into security mode if the heater was on more than 70% of the time)
|
||||
- security_default_on_percent: 0.4 (40% - in security mode, we maintain 40% heating time to avoid getting too cold)
|
||||
- safety_delay_min: 60 minutes (because these sensors are sluggish)
|
||||
- safety_min_on_percent: 0.7 (70% - the system goes into security mode if the heater was on more than 70% of the time)
|
||||
- safety_default_on_percent: 0.4 (40% - in security mode, we maintain 40% heating time to avoid getting too cold)
|
||||
|
||||
These settings should be understood as follows:
|
||||
|
||||
@@ -35,9 +35,9 @@ Versatile Thermostat allows you to be notified when such an event occurs. Set up
|
||||
## Reactive Temperature Sensor (plugged in)
|
||||
A powered thermometer is supposed to be very regular in sending temperature readings. If it doesn't send anything for 15 minutes, it most likely has an issue, and we can react faster without the risk of a false positive.
|
||||
|
||||
- security_delay_min: 15 minutes
|
||||
- security_min_on_percent: 0.5 (50% - the system goes into ``security`` preset if the heater was on more than 50% of the time)
|
||||
- security_default_on_percent: 0.25 (25% - in ``security`` preset, we keep 25% heating time)
|
||||
- safety_delay_min: 15 minutes
|
||||
- safety_min_on_percent: 0.5 (50% - the system goes into ``security`` preset if the heater was on more than 50% of the time)
|
||||
- safety_default_on_percent: 0.25 (25% - in ``security`` preset, we keep 25% heating time)
|
||||
|
||||
## My Presets
|
||||
This is just an example of how I use the preset. You can adapt it to your configuration, but it may be useful to understand its functionality.
|
||||
|
||||