Add temporal filter for calculate_shedding
Add restore overpowering state at startup
This commit is contained in:
@@ -27,7 +27,7 @@ class BaseFeatureManager:
|
|||||||
"""Initialize the attributes of the FeatureManager"""
|
"""Initialize the attributes of the FeatureManager"""
|
||||||
raise NotImplementedError()
|
raise NotImplementedError()
|
||||||
|
|
||||||
def start_listening(self):
|
async def start_listening(self):
|
||||||
"""Start listening the underlying entity"""
|
"""Start listening the underlying entity"""
|
||||||
raise NotImplementedError()
|
raise NotImplementedError()
|
||||||
|
|
||||||
|
|||||||
@@ -53,7 +53,7 @@ from homeassistant.const import (
|
|||||||
)
|
)
|
||||||
|
|
||||||
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
|
from .const import * # pylint: disable=wildcard-import, unused-wildcard-import
|
||||||
from .commons import ConfigData, T, deprecated
|
from .commons import ConfigData, T
|
||||||
|
|
||||||
from .config_schema import * # pylint: disable=wildcard-import, unused-wildcard-import
|
from .config_schema import * # pylint: disable=wildcard-import, unused-wildcard-import
|
||||||
|
|
||||||
@@ -478,7 +478,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
|||||||
|
|
||||||
# start listening for all managers
|
# start listening for all managers
|
||||||
for manager in self._managers:
|
for manager in self._managers:
|
||||||
manager.start_listening()
|
await manager.start_listening()
|
||||||
|
|
||||||
await self.get_my_previous_state()
|
await self.get_my_previous_state()
|
||||||
|
|
||||||
@@ -1957,7 +1957,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
|||||||
def _set_now(self, now: datetime):
|
def _set_now(self, now: datetime):
|
||||||
"""Set the now timestamp. This is only for tests purpose
|
"""Set the now timestamp. This is only for tests purpose
|
||||||
This method should be replaced by the vthermAPI equivalent"""
|
This method should be replaced by the vthermAPI equivalent"""
|
||||||
VersatileThermostatAPI.get_vtherm_api(self._hass)._set_now(now)
|
VersatileThermostatAPI.get_vtherm_api(self._hass)._set_now(now) # pylint: disable=protected-access
|
||||||
|
|
||||||
# @deprecated
|
# @deprecated
|
||||||
@property
|
@property
|
||||||
@@ -1968,8 +1968,8 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
|
|||||||
|
|
||||||
@property
|
@property
|
||||||
def power_percent(self) -> float | None:
|
def power_percent(self) -> float | None:
|
||||||
"""Get the current on_percent as a percentage value. valid only for Vtherm with a TPI algo"""
|
"""Get the current on_percent as a percentage value. valid only for Vtherm with a TPI algo
|
||||||
"""Get the current on_percent value"""
|
Get the current on_percent value"""
|
||||||
if self._prop_algorithm and self._prop_algorithm.on_percent is not None:
|
if self._prop_algorithm and self._prop_algorithm.on_percent is not None:
|
||||||
return round(self._prop_algorithm.on_percent * 100, 0)
|
return round(self._prop_algorithm.on_percent * 100, 0)
|
||||||
else:
|
else:
|
||||||
|
|||||||
@@ -4,11 +4,14 @@ import logging
|
|||||||
from typing import Any
|
from typing import Any
|
||||||
from functools import cmp_to_key
|
from functools import cmp_to_key
|
||||||
|
|
||||||
|
from datetime import timedelta
|
||||||
|
|
||||||
from homeassistant.const import STATE_OFF
|
from homeassistant.const import STATE_OFF
|
||||||
from homeassistant.core import HomeAssistant, Event, callback
|
from homeassistant.core import HomeAssistant, Event, callback
|
||||||
from homeassistant.helpers.event import (
|
from homeassistant.helpers.event import (
|
||||||
async_track_state_change_event,
|
async_track_state_change_event,
|
||||||
EventStateChangedData,
|
EventStateChangedData,
|
||||||
|
async_call_later,
|
||||||
)
|
)
|
||||||
from homeassistant.helpers.entity_component import EntityComponent
|
from homeassistant.helpers.entity_component import EntityComponent
|
||||||
from homeassistant.components.climate import (
|
from homeassistant.components.climate import (
|
||||||
@@ -43,6 +46,8 @@ class CentralFeaturePowerManager(BaseFeatureManager):
|
|||||||
self._current_power: float = None
|
self._current_power: float = None
|
||||||
self._current_max_power: float = None
|
self._current_max_power: float = None
|
||||||
self._power_temp: float = None
|
self._power_temp: float = None
|
||||||
|
self._cancel_calculate_shedding_call = None
|
||||||
|
# Not used now
|
||||||
self._last_shedding_date = None
|
self._last_shedding_date = None
|
||||||
|
|
||||||
def post_init(self, entry_infos: ConfigData):
|
def post_init(self, entry_infos: ConfigData):
|
||||||
@@ -69,7 +74,7 @@ class CentralFeaturePowerManager(BaseFeatureManager):
|
|||||||
else:
|
else:
|
||||||
_LOGGER.info("Power management is not fully configured and will be deactivated")
|
_LOGGER.info("Power management is not fully configured and will be deactivated")
|
||||||
|
|
||||||
def start_listening(self):
|
async def start_listening(self):
|
||||||
"""Start listening the power sensor"""
|
"""Start listening the power sensor"""
|
||||||
if not self._is_configured:
|
if not self._is_configured:
|
||||||
return
|
return
|
||||||
@@ -110,39 +115,47 @@ class CentralFeaturePowerManager(BaseFeatureManager):
|
|||||||
async def refresh_state(self) -> bool:
|
async def refresh_state(self) -> bool:
|
||||||
"""Tries to get the last state from sensor
|
"""Tries to get the last state from sensor
|
||||||
Returns True if a change has been made"""
|
Returns True if a change has been made"""
|
||||||
ret = False
|
|
||||||
if self._is_configured:
|
|
||||||
# try to acquire current power and power max
|
|
||||||
if (
|
|
||||||
new_state := get_safe_float(self._hass, self._power_sensor_entity_id)
|
|
||||||
) is not None:
|
|
||||||
self._current_power = new_state
|
|
||||||
_LOGGER.debug("Current power have been retrieved: %.3f", self._current_power)
|
|
||||||
ret = True
|
|
||||||
|
|
||||||
# Try to acquire power max
|
async def _calculate_shedding_internal(_):
|
||||||
if (
|
_LOGGER.debug("Do the shedding calculation")
|
||||||
new_state := get_safe_float(
|
await self.calculate_shedding()
|
||||||
self._hass, self._max_power_sensor_entity_id
|
if self._cancel_calculate_shedding_call:
|
||||||
)
|
self._cancel_calculate_shedding_call()
|
||||||
) is not None:
|
self._cancel_calculate_shedding_call = None
|
||||||
self._current_max_power = new_state
|
|
||||||
_LOGGER.debug("Current power max have been retrieved: %.3f", self._current_max_power)
|
|
||||||
ret = True
|
|
||||||
|
|
||||||
# check if we need to re-calculate shedding
|
if not self._is_configured:
|
||||||
if ret:
|
return False
|
||||||
now = self._vtherm_api.now
|
|
||||||
dtimestamp = (
|
|
||||||
(now - self._last_shedding_date).seconds
|
|
||||||
if self._last_shedding_date
|
|
||||||
else 999
|
|
||||||
)
|
|
||||||
if dtimestamp >= MIN_DTEMP_SECS:
|
|
||||||
await self.calculate_shedding()
|
|
||||||
self._last_shedding_date = now
|
|
||||||
|
|
||||||
return ret
|
# Retrieve current power
|
||||||
|
new_power = get_safe_float(self._hass, self._power_sensor_entity_id)
|
||||||
|
power_changed = new_power is not None and self._current_power != new_power
|
||||||
|
if power_changed:
|
||||||
|
self._current_power = new_power
|
||||||
|
_LOGGER.debug("New current power has been retrieved: %.3f", self._current_power)
|
||||||
|
|
||||||
|
# Retrieve max power
|
||||||
|
new_max_power = get_safe_float(self._hass, self._max_power_sensor_entity_id)
|
||||||
|
max_power_changed = new_max_power is not None and self._current_max_power != new_max_power
|
||||||
|
if max_power_changed:
|
||||||
|
self._current_max_power = new_max_power
|
||||||
|
_LOGGER.debug("New current max power has been retrieved: %.3f", self._current_max_power)
|
||||||
|
|
||||||
|
# Schedule shedding calculation if there's any change
|
||||||
|
if power_changed or max_power_changed:
|
||||||
|
if not self._cancel_calculate_shedding_call:
|
||||||
|
self._cancel_calculate_shedding_call = async_call_later(self.hass, timedelta(seconds=MIN_DTEMP_SECS), _calculate_shedding_internal)
|
||||||
|
return True
|
||||||
|
|
||||||
|
return False
|
||||||
|
|
||||||
|
# For testing purpose only, do an immediate shedding calculation
|
||||||
|
async def _do_immediate_shedding(self):
|
||||||
|
"""Do an immmediate shedding calculation if a timer was programmed.
|
||||||
|
Else, do nothing"""
|
||||||
|
if self._cancel_calculate_shedding_call:
|
||||||
|
self._cancel_calculate_shedding_call()
|
||||||
|
self._cancel_calculate_shedding_call = None
|
||||||
|
await self.calculate_shedding()
|
||||||
|
|
||||||
async def calculate_shedding(self):
|
async def calculate_shedding(self):
|
||||||
"""Do the shedding calculation and set/unset VTherm into overpowering state"""
|
"""Do the shedding calculation and set/unset VTherm into overpowering state"""
|
||||||
@@ -197,14 +210,15 @@ class CentralFeaturePowerManager(BaseFeatureManager):
|
|||||||
)
|
)
|
||||||
|
|
||||||
_LOGGER.debug("vtherm %s power_consumption_max is %s (device_power=%s, overclimate=%s)", vtherm.name, power_consumption_max, device_power, vtherm.is_over_climate)
|
_LOGGER.debug("vtherm %s power_consumption_max is %s (device_power=%s, overclimate=%s)", vtherm.name, power_consumption_max, device_power, vtherm.is_over_climate)
|
||||||
# if total_power_added + power_consumption_max < available_power or not vtherm.power_manager.is_overpowering_detected:
|
|
||||||
_LOGGER.info("vtherm %s should not be in overpowering state (power_consumption_max=%.2f)", vtherm.name, power_consumption_max)
|
|
||||||
|
|
||||||
# we count the unshedding only if the VTherm was in shedding
|
# or not ... is for initializing the overpowering state if not already done
|
||||||
if vtherm.power_manager.is_overpowering_detected:
|
if total_power_added + power_consumption_max < available_power or not vtherm.power_manager.is_overpowering_detected:
|
||||||
total_power_added += power_consumption_max
|
# we count the unshedding only if the VTherm was in shedding
|
||||||
|
if vtherm.power_manager.is_overpowering_detected:
|
||||||
|
_LOGGER.info("vtherm %s should not be in overpowering state (power_consumption_max=%.2f)", vtherm.name, power_consumption_max)
|
||||||
|
total_power_added += power_consumption_max
|
||||||
|
|
||||||
await vtherm.power_manager.set_overpowering(False)
|
await vtherm.power_manager.set_overpowering(False)
|
||||||
|
|
||||||
if total_power_added >= available_power:
|
if total_power_added >= available_power:
|
||||||
_LOGGER.debug("We have found enough vtherm to set to non-overpowering")
|
_LOGGER.debug("We have found enough vtherm to set to non-overpowering")
|
||||||
@@ -212,6 +226,7 @@ class CentralFeaturePowerManager(BaseFeatureManager):
|
|||||||
|
|
||||||
_LOGGER.debug("after vtherm %s total_power_added=%s, available_power=%s", vtherm.name, total_power_added, available_power)
|
_LOGGER.debug("after vtherm %s total_power_added=%s, available_power=%s", vtherm.name, total_power_added, available_power)
|
||||||
|
|
||||||
|
self._last_shedding_date = self._vtherm_api.now
|
||||||
_LOGGER.debug("-------- End of calculate_shedding")
|
_LOGGER.debug("-------- End of calculate_shedding")
|
||||||
|
|
||||||
def get_climate_components_entities(self) -> list:
|
def get_climate_components_entities(self) -> list:
|
||||||
|
|||||||
@@ -71,7 +71,7 @@ class FeatureAutoStartStopManager(BaseFeatureManager):
|
|||||||
)
|
)
|
||||||
|
|
||||||
@overrides
|
@overrides
|
||||||
def start_listening(self):
|
async def start_listening(self):
|
||||||
"""Start listening the underlying entity"""
|
"""Start listening the underlying entity"""
|
||||||
|
|
||||||
@overrides
|
@overrides
|
||||||
|
|||||||
@@ -86,7 +86,7 @@ class FeatureMotionManager(BaseFeatureManager):
|
|||||||
self._motion_state = STATE_UNKNOWN
|
self._motion_state = STATE_UNKNOWN
|
||||||
|
|
||||||
@overrides
|
@overrides
|
||||||
def start_listening(self):
|
async def start_listening(self):
|
||||||
"""Start listening the underlying entity"""
|
"""Start listening the underlying entity"""
|
||||||
if self._is_configured:
|
if self._is_configured:
|
||||||
self.stop_listening()
|
self.stop_listening()
|
||||||
|
|||||||
@@ -61,19 +61,21 @@ class FeaturePowerManager(BaseFeatureManager):
|
|||||||
self._is_configured = False
|
self._is_configured = False
|
||||||
|
|
||||||
@overrides
|
@overrides
|
||||||
def start_listening(self):
|
async def start_listening(self):
|
||||||
"""Start listening the underlying entity. There is nothing to listen"""
|
"""Start listening the underlying entity. There is nothing to listen"""
|
||||||
central_power_configuration = (
|
central_power_configuration = (
|
||||||
VersatileThermostatAPI.get_vtherm_api().central_power_manager.is_configured
|
VersatileThermostatAPI.get_vtherm_api().central_power_manager.is_configured
|
||||||
)
|
)
|
||||||
|
|
||||||
if (
|
if self._use_power_feature and self._device_power and central_power_configuration:
|
||||||
self._use_power_feature
|
|
||||||
and self._device_power
|
|
||||||
and central_power_configuration
|
|
||||||
):
|
|
||||||
self._is_configured = True
|
self._is_configured = True
|
||||||
self._overpowering_state = STATE_UNKNOWN
|
# Try to restore _overpowering_state from previous state
|
||||||
|
old_state = await self._vtherm.async_get_last_state()
|
||||||
|
self._overpowering_state = (
|
||||||
|
old_state.attributes.get("overpowering_state", STATE_UNKNOWN)
|
||||||
|
if old_state and old_state.attributes and old_state.attributes in (STATE_OFF, STATE_ON)
|
||||||
|
else STATE_UNKNOWN
|
||||||
|
)
|
||||||
else:
|
else:
|
||||||
if self._use_power_feature:
|
if self._use_power_feature:
|
||||||
if not central_power_configuration:
|
if not central_power_configuration:
|
||||||
|
|||||||
@@ -67,7 +67,7 @@ class FeaturePresenceManager(BaseFeatureManager):
|
|||||||
self._presence_state = STATE_UNKNOWN
|
self._presence_state = STATE_UNKNOWN
|
||||||
|
|
||||||
@overrides
|
@overrides
|
||||||
def start_listening(self):
|
async def start_listening(self):
|
||||||
"""Start listening the underlying entity"""
|
"""Start listening the underlying entity"""
|
||||||
if self._is_configured:
|
if self._is_configured:
|
||||||
self.stop_listening()
|
self.stop_listening()
|
||||||
|
|||||||
@@ -70,7 +70,7 @@ class FeatureSafetyManager(BaseFeatureManager):
|
|||||||
self._is_configured = True
|
self._is_configured = True
|
||||||
|
|
||||||
@overrides
|
@overrides
|
||||||
def start_listening(self):
|
async def start_listening(self):
|
||||||
"""Start listening the underlying entity"""
|
"""Start listening the underlying entity"""
|
||||||
|
|
||||||
@overrides
|
@overrides
|
||||||
|
|||||||
@@ -124,7 +124,7 @@ class FeatureWindowManager(BaseFeatureManager):
|
|||||||
self._window_state = STATE_UNKNOWN
|
self._window_state = STATE_UNKNOWN
|
||||||
|
|
||||||
@overrides
|
@overrides
|
||||||
def start_listening(self):
|
async def start_listening(self):
|
||||||
"""Start listening the underlying entity"""
|
"""Start listening the underlying entity"""
|
||||||
if self._is_configured:
|
if self._is_configured:
|
||||||
self.stop_listening()
|
self.stop_listening()
|
||||||
|
|||||||
@@ -26,23 +26,21 @@ _LOGGER = logging.getLogger(__name__)
|
|||||||
class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
|
class ThermostatOverSwitch(BaseThermostat[UnderlyingSwitch]):
|
||||||
"""Representation of a base class for a Versatile Thermostat over a switch."""
|
"""Representation of a base class for a Versatile Thermostat over a switch."""
|
||||||
|
|
||||||
_entity_component_unrecorded_attributes = (
|
_entity_component_unrecorded_attributes = BaseThermostat._entity_component_unrecorded_attributes.union( # pylint: disable=protected-access
|
||||||
BaseThermostat._entity_component_unrecorded_attributes.union(
|
frozenset(
|
||||||
frozenset(
|
{
|
||||||
{
|
"is_over_switch",
|
||||||
"is_over_switch",
|
"is_inversed",
|
||||||
"is_inversed",
|
"underlying_entities",
|
||||||
"underlying_entities",
|
"on_time_sec",
|
||||||
"on_time_sec",
|
"off_time_sec",
|
||||||
"off_time_sec",
|
"cycle_min",
|
||||||
"cycle_min",
|
"function",
|
||||||
"function",
|
"tpi_coef_int",
|
||||||
"tpi_coef_int",
|
"tpi_coef_ext",
|
||||||
"tpi_coef_ext",
|
"power_percent",
|
||||||
"power_percent",
|
"calculated_on_percent",
|
||||||
"calculated_on_percent",
|
}
|
||||||
}
|
|
||||||
)
|
|
||||||
)
|
)
|
||||||
)
|
)
|
||||||
|
|
||||||
|
|||||||
@@ -188,7 +188,7 @@ class VersatileThermostatAPI(dict):
|
|||||||
|
|
||||||
# start listening for the central power manager if not only one vtherm reload
|
# start listening for the central power manager if not only one vtherm reload
|
||||||
if not entry_id:
|
if not entry_id:
|
||||||
self.central_power_manager.start_listening()
|
await self.central_power_manager.start_listening()
|
||||||
|
|
||||||
async def init_vtherm_preset_with_central(self):
|
async def init_vtherm_preset_with_central(self):
|
||||||
"""Init all VTherm presets when the VTherm uses central temperature"""
|
"""Init all VTherm presets when the VTherm uses central temperature"""
|
||||||
|
|||||||
@@ -751,6 +751,7 @@ async def send_power_change_event(entity: BaseThermostat, new_power, date, sleep
|
|||||||
)
|
)
|
||||||
vtherm_api = VersatileThermostatAPI.get_vtherm_api()
|
vtherm_api = VersatileThermostatAPI.get_vtherm_api()
|
||||||
await vtherm_api.central_power_manager._power_sensor_changed(power_event)
|
await vtherm_api.central_power_manager._power_sensor_changed(power_event)
|
||||||
|
await vtherm_api.central_power_manager._do_immediate_shedding()
|
||||||
if sleep:
|
if sleep:
|
||||||
await entity.hass.async_block_till_done()
|
await entity.hass.async_block_till_done()
|
||||||
|
|
||||||
@@ -778,6 +779,7 @@ async def send_max_power_change_event(
|
|||||||
)
|
)
|
||||||
vtherm_api = VersatileThermostatAPI.get_vtherm_api()
|
vtherm_api = VersatileThermostatAPI.get_vtherm_api()
|
||||||
await vtherm_api.central_power_manager._max_power_sensor_changed(power_event)
|
await vtherm_api.central_power_manager._max_power_sensor_changed(power_event)
|
||||||
|
await vtherm_api.central_power_manager._do_immediate_shedding()
|
||||||
if sleep:
|
if sleep:
|
||||||
await entity.hass.async_block_till_done()
|
await entity.hass.async_block_till_done()
|
||||||
|
|
||||||
|
|||||||
@@ -192,13 +192,13 @@ async def test_overpowering_binary_sensors(
|
|||||||
assert overpowering_binary_sensor.state == STATE_ON
|
assert overpowering_binary_sensor.state == STATE_ON
|
||||||
|
|
||||||
# set max power to a low value
|
# set max power to a low value
|
||||||
side_effects.add_or_update_side_effect("sensor.the_max_power_sensor", State("sensor.the_max_power_sensor", 201))
|
side_effects.add_or_update_side_effect("sensor.the_max_power_sensor", State("sensor.the_max_power_sensor", 251))
|
||||||
# fmt:off
|
# fmt:off
|
||||||
with patch("homeassistant.core.StateMachine.get", side_effect=side_effects.get_side_effects()):
|
with patch("homeassistant.core.StateMachine.get", side_effect=side_effects.get_side_effects()):
|
||||||
# fmt: on
|
# fmt: on
|
||||||
now = now + timedelta(seconds=30)
|
now = now + timedelta(seconds=30)
|
||||||
VersatileThermostatAPI.get_vtherm_api()._set_now(now)
|
VersatileThermostatAPI.get_vtherm_api()._set_now(now)
|
||||||
await send_max_power_change_event(entity, 201, now)
|
await send_max_power_change_event(entity, 251, now)
|
||||||
assert entity.power_manager.is_overpowering_detected is False
|
assert entity.power_manager.is_overpowering_detected is False
|
||||||
assert entity.power_manager.overpowering_state is STATE_OFF
|
assert entity.power_manager.overpowering_state is STATE_OFF
|
||||||
# Simulate the event reception
|
# Simulate the event reception
|
||||||
|
|||||||
@@ -59,7 +59,7 @@ async def test_central_power_manager_init(
|
|||||||
assert central_power_manager.power_temperature == power_temp
|
assert central_power_manager.power_temperature == power_temp
|
||||||
|
|
||||||
# 3. start listening
|
# 3. start listening
|
||||||
central_power_manager.start_listening()
|
await central_power_manager.start_listening()
|
||||||
assert len(central_power_manager._active_listener) == (2 if is_configured else 0)
|
assert len(central_power_manager._active_listener) == (2 if is_configured else 0)
|
||||||
|
|
||||||
# 4. stop listening
|
# 4. stop listening
|
||||||
@@ -311,6 +311,54 @@ async def test_central_power_manageer_find_vtherms(
|
|||||||
# init vtherm1 to False
|
# init vtherm1 to False
|
||||||
{"vtherm3": False, "vtherm2": False, "vtherm1": False},
|
{"vtherm3": False, "vtherm2": False, "vtherm1": False},
|
||||||
),
|
),
|
||||||
|
# Un-shedding only (will be taken in reverse order)
|
||||||
|
(
|
||||||
|
1000,
|
||||||
|
2000,
|
||||||
|
[
|
||||||
|
# should be not unshedded (too much power will be added)
|
||||||
|
{
|
||||||
|
"name": "vtherm1",
|
||||||
|
"device_power": 800,
|
||||||
|
"is_device_active": False,
|
||||||
|
"is_over_climate": False,
|
||||||
|
"nb_underlying_entities": 1,
|
||||||
|
"on_percent": 1,
|
||||||
|
"is_overpowering_detected": True,
|
||||||
|
"overpowering_state": STATE_ON,
|
||||||
|
},
|
||||||
|
# already stay unshedded cause already unshedded
|
||||||
|
{
|
||||||
|
"name": "vtherm2",
|
||||||
|
"device_power": 100,
|
||||||
|
"is_device_active": True,
|
||||||
|
"is_over_climate": True,
|
||||||
|
"is_overpowering_detected": False,
|
||||||
|
"overpowering_state": STATE_OFF,
|
||||||
|
},
|
||||||
|
# should be unshedded
|
||||||
|
{
|
||||||
|
"name": "vtherm3",
|
||||||
|
"device_power": 200,
|
||||||
|
"is_device_active": False,
|
||||||
|
"is_over_climate": True,
|
||||||
|
"is_overpowering_detected": True,
|
||||||
|
"overpowering_state": STATE_ON,
|
||||||
|
},
|
||||||
|
# should be unshedded
|
||||||
|
{
|
||||||
|
"name": "vtherm4",
|
||||||
|
"device_power": 300,
|
||||||
|
"is_device_active": False,
|
||||||
|
"is_over_climate": False,
|
||||||
|
"nb_underlying_entities": 1,
|
||||||
|
"on_percent": 1,
|
||||||
|
"is_overpowering_detected": True,
|
||||||
|
"overpowering_state": STATE_ON,
|
||||||
|
},
|
||||||
|
],
|
||||||
|
{"vtherm4": False, "vtherm3": False},
|
||||||
|
),
|
||||||
# Shedding
|
# Shedding
|
||||||
(
|
(
|
||||||
2000,
|
2000,
|
||||||
@@ -391,65 +439,6 @@ async def test_central_power_manageer_find_vtherms(
|
|||||||
],
|
],
|
||||||
{"vtherm1": True, "vtherm2": True, "vtherm3": True, "vtherm6": True},
|
{"vtherm1": True, "vtherm2": True, "vtherm3": True, "vtherm6": True},
|
||||||
),
|
),
|
||||||
# Un-shedding only (will be taken in reverse order)
|
|
||||||
(
|
|
||||||
1000,
|
|
||||||
2000,
|
|
||||||
[
|
|
||||||
# should be not unshedded (we have enough)
|
|
||||||
{
|
|
||||||
"name": "vtherm0",
|
|
||||||
"device_power": 800,
|
|
||||||
"is_device_active": False,
|
|
||||||
"is_over_climate": False,
|
|
||||||
"nb_underlying_entities": 1,
|
|
||||||
"on_percent": 1,
|
|
||||||
"is_overpowering_detected": True,
|
|
||||||
"overpowering_state": STATE_ON,
|
|
||||||
},
|
|
||||||
# should be unshedded
|
|
||||||
{
|
|
||||||
"name": "vtherm1",
|
|
||||||
"device_power": 800,
|
|
||||||
"is_device_active": False,
|
|
||||||
"is_over_climate": False,
|
|
||||||
"nb_underlying_entities": 1,
|
|
||||||
"on_percent": 1,
|
|
||||||
"is_overpowering_detected": True,
|
|
||||||
"overpowering_state": STATE_ON,
|
|
||||||
},
|
|
||||||
# already stay unshedded cause already unshedded
|
|
||||||
{
|
|
||||||
"name": "vtherm2",
|
|
||||||
"device_power": 1100,
|
|
||||||
"is_device_active": True,
|
|
||||||
"is_over_climate": True,
|
|
||||||
"is_overpowering_detected": False,
|
|
||||||
"overpowering_state": STATE_OFF,
|
|
||||||
},
|
|
||||||
# should be unshedded
|
|
||||||
{
|
|
||||||
"name": "vtherm3",
|
|
||||||
"device_power": 200,
|
|
||||||
"is_device_active": False,
|
|
||||||
"is_over_climate": True,
|
|
||||||
"is_overpowering_detected": True,
|
|
||||||
"overpowering_state": STATE_ON,
|
|
||||||
},
|
|
||||||
# should be unshedded
|
|
||||||
{
|
|
||||||
"name": "vtherm4",
|
|
||||||
"device_power": 300,
|
|
||||||
"is_device_active": False,
|
|
||||||
"is_over_climate": False,
|
|
||||||
"nb_underlying_entities": 1,
|
|
||||||
"on_percent": 1,
|
|
||||||
"is_overpowering_detected": True,
|
|
||||||
"overpowering_state": STATE_ON,
|
|
||||||
},
|
|
||||||
],
|
|
||||||
{"vtherm4": False, "vtherm3": False, "vtherm1": False},
|
|
||||||
),
|
|
||||||
],
|
],
|
||||||
)
|
)
|
||||||
# @pytest.mark.skip
|
# @pytest.mark.skip
|
||||||
@@ -553,7 +542,7 @@ async def test_central_power_manager_power_event(
|
|||||||
assert central_power_manager.power_temperature == 13
|
assert central_power_manager.power_temperature == 13
|
||||||
|
|
||||||
# 3. start listening (not really useful but don't eat bread)
|
# 3. start listening (not really useful but don't eat bread)
|
||||||
central_power_manager.start_listening()
|
await central_power_manager.start_listening()
|
||||||
assert len(central_power_manager._active_listener) == 2
|
assert len(central_power_manager._active_listener) == 2
|
||||||
|
|
||||||
now: datetime = NowClass.get_now(hass)
|
now: datetime = NowClass.get_now(hass)
|
||||||
@@ -582,6 +571,9 @@ async def test_central_power_manager_power_event(
|
|||||||
"old_state": State("sensor.power_entity_id", STATE_UNAVAILABLE),
|
"old_state": State("sensor.power_entity_id", STATE_UNAVAILABLE),
|
||||||
}))
|
}))
|
||||||
|
|
||||||
|
if nb_call > 0:
|
||||||
|
await central_power_manager._do_immediate_shedding()
|
||||||
|
|
||||||
expected_power = power if isinstance(power, (int, float)) else -999
|
expected_power = power if isinstance(power, (int, float)) else -999
|
||||||
assert central_power_manager.current_power == expected_power
|
assert central_power_manager.current_power == expected_power
|
||||||
assert mock_calculate_shedding.call_count == nb_call
|
assert mock_calculate_shedding.call_count == nb_call
|
||||||
@@ -603,8 +595,11 @@ async def test_central_power_manager_power_event(
|
|||||||
"old_state": State("sensor.power_entity_id", STATE_UNAVAILABLE),
|
"old_state": State("sensor.power_entity_id", STATE_UNAVAILABLE),
|
||||||
}))
|
}))
|
||||||
|
|
||||||
|
if nb_call > 0:
|
||||||
|
await central_power_manager._do_immediate_shedding()
|
||||||
|
|
||||||
assert central_power_manager.current_power == expected_power
|
assert central_power_manager.current_power == expected_power
|
||||||
assert mock_calculate_shedding.call_count == (nb_call if dsecs >= 20 else 0)
|
assert mock_calculate_shedding.call_count == nb_call
|
||||||
|
|
||||||
|
|
||||||
@pytest.mark.parametrize(
|
@pytest.mark.parametrize(
|
||||||
@@ -645,7 +640,7 @@ async def test_central_power_manager_max_power_event(
|
|||||||
assert central_power_manager.power_temperature == 13
|
assert central_power_manager.power_temperature == 13
|
||||||
|
|
||||||
# 3. start listening (not really useful but don't eat bread)
|
# 3. start listening (not really useful but don't eat bread)
|
||||||
central_power_manager.start_listening()
|
await central_power_manager.start_listening()
|
||||||
assert len(central_power_manager._active_listener) == 2
|
assert len(central_power_manager._active_listener) == 2
|
||||||
|
|
||||||
now: datetime = NowClass.get_now(hass)
|
now: datetime = NowClass.get_now(hass)
|
||||||
@@ -676,6 +671,9 @@ async def test_central_power_manager_max_power_event(
|
|||||||
"old_state": State("sensor.max_power_entity_id", STATE_UNAVAILABLE),
|
"old_state": State("sensor.max_power_entity_id", STATE_UNAVAILABLE),
|
||||||
}))
|
}))
|
||||||
|
|
||||||
|
if nb_call > 0:
|
||||||
|
await central_power_manager._do_immediate_shedding()
|
||||||
|
|
||||||
expected_power = max_power if isinstance(max_power, (int, float)) else -999
|
expected_power = max_power if isinstance(max_power, (int, float)) else -999
|
||||||
assert central_power_manager.current_max_power == expected_power
|
assert central_power_manager.current_max_power == expected_power
|
||||||
assert mock_calculate_shedding.call_count == nb_call
|
assert mock_calculate_shedding.call_count == nb_call
|
||||||
@@ -697,5 +695,8 @@ async def test_central_power_manager_max_power_event(
|
|||||||
"old_state": State("sensor.max_power_entity_id", STATE_UNAVAILABLE),
|
"old_state": State("sensor.max_power_entity_id", STATE_UNAVAILABLE),
|
||||||
}))
|
}))
|
||||||
|
|
||||||
|
if nb_call > 0:
|
||||||
|
await central_power_manager._do_immediate_shedding()
|
||||||
|
|
||||||
assert central_power_manager.current_max_power == expected_power
|
assert central_power_manager.current_max_power == expected_power
|
||||||
assert mock_calculate_shedding.call_count == (nb_call if dsecs >= 20 else 0)
|
assert mock_calculate_shedding.call_count == nb_call
|
||||||
|
|||||||
@@ -90,7 +90,7 @@ async def test_motion_feature_manager_refresh(
|
|||||||
assert custom_attributes["motion_off_delay_sec"] == 30
|
assert custom_attributes["motion_off_delay_sec"] == 30
|
||||||
|
|
||||||
# 3. start listening
|
# 3. start listening
|
||||||
motion_manager.start_listening()
|
await motion_manager.start_listening()
|
||||||
assert motion_manager.is_configured is True
|
assert motion_manager.is_configured is True
|
||||||
assert motion_manager.motion_state == STATE_UNKNOWN
|
assert motion_manager.motion_state == STATE_UNKNOWN
|
||||||
assert motion_manager.is_motion_detected is False
|
assert motion_manager.is_motion_detected is False
|
||||||
@@ -198,7 +198,7 @@ async def test_motion_feature_manager_event(
|
|||||||
CONF_NO_MOTION_PRESET: PRESET_ECO,
|
CONF_NO_MOTION_PRESET: PRESET_ECO,
|
||||||
}
|
}
|
||||||
)
|
)
|
||||||
motion_manager.start_listening()
|
await motion_manager.start_listening()
|
||||||
|
|
||||||
# 2. test _motion_sensor_changed with the parametrized
|
# 2. test _motion_sensor_changed with the parametrized
|
||||||
# fmt: off
|
# fmt: off
|
||||||
|
|||||||
@@ -98,7 +98,7 @@ async def test_power_feature_manager(
|
|||||||
}
|
}
|
||||||
)
|
)
|
||||||
|
|
||||||
power_manager.start_listening()
|
await power_manager.start_listening()
|
||||||
|
|
||||||
assert power_manager.is_configured is True
|
assert power_manager.is_configured is True
|
||||||
assert power_manager.overpowering_state == STATE_UNKNOWN
|
assert power_manager.overpowering_state == STATE_UNKNOWN
|
||||||
@@ -117,7 +117,7 @@ async def test_power_feature_manager(
|
|||||||
assert custom_attributes["current_max_power"] is None
|
assert custom_attributes["current_max_power"] is None
|
||||||
|
|
||||||
# 3. start listening
|
# 3. start listening
|
||||||
power_manager.start_listening()
|
await power_manager.start_listening()
|
||||||
assert power_manager.is_configured is True
|
assert power_manager.is_configured is True
|
||||||
assert power_manager.overpowering_state == STATE_UNKNOWN
|
assert power_manager.overpowering_state == STATE_UNKNOWN
|
||||||
|
|
||||||
@@ -199,7 +199,7 @@ async def test_power_feature_manager_set_overpowering(
|
|||||||
}
|
}
|
||||||
)
|
)
|
||||||
|
|
||||||
power_manager.start_listening()
|
await power_manager.start_listening()
|
||||||
|
|
||||||
assert power_manager.is_configured is True
|
assert power_manager.is_configured is True
|
||||||
assert power_manager.overpowering_state == STATE_UNKNOWN
|
assert power_manager.overpowering_state == STATE_UNKNOWN
|
||||||
@@ -557,6 +557,7 @@ async def test_power_management_hvac_on(
|
|||||||
|
|
||||||
# Send power mesurement low to unset power preset
|
# Send power mesurement low to unset power preset
|
||||||
side_effects.add_or_update_side_effect("sensor.the_power_sensor", State("sensor.the_power_sensor", 48))
|
side_effects.add_or_update_side_effect("sensor.the_power_sensor", State("sensor.the_power_sensor", 48))
|
||||||
|
side_effects.add_or_update_side_effect("sensor.the_max_power_sensor", State("sensor.the_max_power_sensor", 149))
|
||||||
# fmt:off
|
# fmt:off
|
||||||
with patch("homeassistant.core.StateMachine.get", side_effect=side_effects.get_side_effects()), \
|
with patch("homeassistant.core.StateMachine.get", side_effect=side_effects.get_side_effects()), \
|
||||||
patch("custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event") as mock_send_event, \
|
patch("custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event") as mock_send_event, \
|
||||||
@@ -583,7 +584,7 @@ async def test_power_management_hvac_on(
|
|||||||
"type": "end",
|
"type": "end",
|
||||||
"current_power": 48,
|
"current_power": 48,
|
||||||
"device_power": 100,
|
"device_power": 100,
|
||||||
"current_max_power": 49,
|
"current_max_power": 149,
|
||||||
},
|
},
|
||||||
),
|
),
|
||||||
],
|
],
|
||||||
|
|||||||
@@ -75,7 +75,7 @@ async def test_presence_feature_manager(
|
|||||||
assert custom_attributes["is_presence_configured"] is True
|
assert custom_attributes["is_presence_configured"] is True
|
||||||
|
|
||||||
# 3. start listening
|
# 3. start listening
|
||||||
presence_manager.start_listening()
|
await presence_manager.start_listening()
|
||||||
assert presence_manager.is_configured is True
|
assert presence_manager.is_configured is True
|
||||||
assert presence_manager.presence_state == STATE_UNKNOWN
|
assert presence_manager.presence_state == STATE_UNKNOWN
|
||||||
assert presence_manager.is_absence_detected is False
|
assert presence_manager.is_absence_detected is False
|
||||||
|
|||||||
@@ -170,7 +170,7 @@ async def test_window_feature_manager_refresh_sensor_action_turn_off(
|
|||||||
)
|
)
|
||||||
|
|
||||||
# 3. start listening
|
# 3. start listening
|
||||||
window_manager.start_listening()
|
await window_manager.start_listening()
|
||||||
assert window_manager.is_configured is True
|
assert window_manager.is_configured is True
|
||||||
assert window_manager.window_state == STATE_UNKNOWN
|
assert window_manager.window_state == STATE_UNKNOWN
|
||||||
assert window_manager.window_auto_state == STATE_UNAVAILABLE
|
assert window_manager.window_auto_state == STATE_UNAVAILABLE
|
||||||
@@ -288,7 +288,7 @@ async def test_window_feature_manager_refresh_sensor_action_frost_only(
|
|||||||
)
|
)
|
||||||
|
|
||||||
# 3. start listening
|
# 3. start listening
|
||||||
window_manager.start_listening()
|
await window_manager.start_listening()
|
||||||
assert window_manager.is_configured is True
|
assert window_manager.is_configured is True
|
||||||
assert window_manager.window_state == STATE_UNKNOWN
|
assert window_manager.window_state == STATE_UNKNOWN
|
||||||
assert window_manager.window_auto_state == STATE_UNAVAILABLE
|
assert window_manager.window_auto_state == STATE_UNAVAILABLE
|
||||||
@@ -408,7 +408,7 @@ async def test_window_feature_manager_sensor_event_action_turn_off(
|
|||||||
)
|
)
|
||||||
|
|
||||||
# 3. start listening
|
# 3. start listening
|
||||||
window_manager.start_listening()
|
await window_manager.start_listening()
|
||||||
assert len(window_manager._active_listener) == 1
|
assert len(window_manager._active_listener) == 1
|
||||||
|
|
||||||
# 4. test refresh with the parametrized
|
# 4. test refresh with the parametrized
|
||||||
@@ -535,7 +535,7 @@ async def test_window_feature_manager_event_sensor_action_frost_only(
|
|||||||
)
|
)
|
||||||
|
|
||||||
# 3. start listening
|
# 3. start listening
|
||||||
window_manager.start_listening()
|
await window_manager.start_listening()
|
||||||
|
|
||||||
# 4. test refresh with the parametrized
|
# 4. test refresh with the parametrized
|
||||||
# fmt:off
|
# fmt:off
|
||||||
@@ -660,7 +660,7 @@ async def test_window_feature_manager_window_auto(
|
|||||||
}
|
}
|
||||||
)
|
)
|
||||||
assert window_manager.is_window_auto_configured is True
|
assert window_manager.is_window_auto_configured is True
|
||||||
window_manager.start_listening()
|
await window_manager.start_listening()
|
||||||
|
|
||||||
# 2. Call manage window auto
|
# 2. Call manage window auto
|
||||||
tz = get_tz(hass) # pylint: disable=invalid-name
|
tz = get_tz(hass) # pylint: disable=invalid-name
|
||||||
|
|||||||
Reference in New Issue