Issue #113 - Add multi thermostat over climate
This commit is contained in:
@@ -129,6 +129,9 @@ from .const import (
|
||||
# CONF_THERMOSTAT_SWITCH,
|
||||
CONF_THERMOSTAT_CLIMATE,
|
||||
CONF_CLIMATE,
|
||||
CONF_CLIMATE_2,
|
||||
CONF_CLIMATE_3,
|
||||
CONF_CLIMATE_4,
|
||||
CONF_AC_MODE,
|
||||
UnknownEntity,
|
||||
EventType,
|
||||
@@ -328,16 +331,19 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
self._cycle_min = entry_infos.get(CONF_CYCLE_MIN)
|
||||
|
||||
# Initialize underlying entities
|
||||
self._underlyings = []
|
||||
self._thermostat_type = entry_infos.get(CONF_THERMOSTAT_TYPE)
|
||||
if self._thermostat_type == CONF_THERMOSTAT_CLIMATE:
|
||||
self._is_over_climate = True
|
||||
self._underlyings.append(
|
||||
UnderlyingClimate(
|
||||
hass=self._hass,
|
||||
thermostat=self,
|
||||
climate_entity_id=entry_infos.get(CONF_CLIMATE),
|
||||
)
|
||||
)
|
||||
for climate in [CONF_CLIMATE, CONF_CLIMATE_2, CONF_CLIMATE_3, CONF_CLIMATE_4]:
|
||||
if entry_infos.get(climate):
|
||||
self._underlyings.append(
|
||||
UnderlyingClimate(
|
||||
hass=self._hass,
|
||||
thermostat=self,
|
||||
climate_entity_id=entry_infos.get(climate),
|
||||
)
|
||||
)
|
||||
else:
|
||||
lst_switches = [entry_infos.get(CONF_HEATER)]
|
||||
if entry_infos.get(CONF_HEATER_2):
|
||||
@@ -348,7 +354,6 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
lst_switches.append(entry_infos.get(CONF_HEATER_4))
|
||||
|
||||
delta_cycle = self._cycle_min * 60 / len(lst_switches)
|
||||
self._underlyings = []
|
||||
for idx, switch in enumerate(lst_switches):
|
||||
self._underlyings.append(
|
||||
UnderlyingSwitch(
|
||||
@@ -1582,6 +1587,7 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
if not new_state:
|
||||
return
|
||||
|
||||
changes = False
|
||||
new_hvac_mode = new_state.state
|
||||
|
||||
old_state = event.data.get("old_state")
|
||||
@@ -1597,9 +1603,9 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
)
|
||||
|
||||
# Issue 99 - some AC turn hvac_mode=cool and hvac_action=idle when sending a HVACMode_OFF command
|
||||
if self._hvac_mode == HVACMode.OFF and new_hvac_action == HVACAction.IDLE:
|
||||
_LOGGER.debug("The underlying switch to idle instead of OFF. We will consider it as OFF")
|
||||
new_hvac_mode = HVACMode.OFF
|
||||
#if self._hvac_mode == HVACMode.OFF and new_hvac_mode == HVACMode.COOL and new_hvac_action == HVACAction.IDLE:
|
||||
# _LOGGER.debug("The underlying switch to idle instead of OFF. We will consider it as OFF")
|
||||
# new_hvac_mode = HVACMode.OFF
|
||||
|
||||
_LOGGER.info(
|
||||
"%s - Underlying climate changed. Event.new_hvac_mode is %s, current_hvac_mode=%s, new_hvac_action=%s, old_hvac_action=%s",
|
||||
@@ -1619,8 +1625,13 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
HVACMode.AUTO,
|
||||
HVACMode.FAN_ONLY,
|
||||
None
|
||||
]:
|
||||
] and self._hvac_mode != new_hvac_mode:
|
||||
changes = True
|
||||
self._hvac_mode = new_hvac_mode
|
||||
# Do not try to update all underlying state, else we will have a loop
|
||||
if self._is_over_climate:
|
||||
for under in self._underlyings:
|
||||
await under.set_hvac_mode(new_hvac_mode)
|
||||
|
||||
# Interpretation of hvac
|
||||
HVAC_ACTION_ON = [ # pylint: disable=invalid-name
|
||||
@@ -1638,6 +1649,7 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
self,
|
||||
self._underlying_climate_start_hvac_action_date.isoformat(),
|
||||
)
|
||||
changes = True
|
||||
|
||||
if old_hvac_action in HVAC_ACTION_ON and new_hvac_action not in HVAC_ACTION_ON:
|
||||
stop_power_date = self.get_last_updated_date_or_now(new_state)
|
||||
@@ -1658,14 +1670,20 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
stop_power_date.isoformat(),
|
||||
self._underlying_climate_delta_t,
|
||||
)
|
||||
changes = True
|
||||
|
||||
# Manage new target temperature set
|
||||
if self._is_over_climate and new_state.attributes and (new_target_temp := new_state.attributes.get("temperature")) and new_target_temp != self.target_temperature:
|
||||
_LOGGER.info("%s - Target temp have change to %s", self, new_target_temp)
|
||||
await self.async_set_temperature(temperature = new_target_temp)
|
||||
if not changes:
|
||||
# try to manage new target temperature set if state
|
||||
_LOGGER.debug("Do temperature check. temperature is %s, new_state.attributes is %s", self.target_temperature, new_state.attributes)
|
||||
if self._is_over_climate and new_state.attributes and (new_target_temp := new_state.attributes.get("temperature")) and new_target_temp != self.target_temperature:
|
||||
_LOGGER.info("%s - Target temp have change to %s", self, new_target_temp)
|
||||
await self.async_set_temperature(temperature = new_target_temp)
|
||||
changes = True
|
||||
|
||||
self.update_custom_attributes()
|
||||
await self._async_control_heating()
|
||||
if changes:
|
||||
self.async_write_ha_state()
|
||||
self.update_custom_attributes()
|
||||
await self._async_control_heating()
|
||||
|
||||
@callback
|
||||
async def _async_update_temp(self, state: State):
|
||||
@@ -2364,9 +2382,19 @@ class VersatileThermostat(ClimateEntity, RestoreEntity):
|
||||
"window_auto_max_duration": self._window_auto_max_duration,
|
||||
}
|
||||
if self._is_over_climate:
|
||||
self._attr_extra_state_attributes["underlying_climate"] = self._underlyings[
|
||||
self._attr_extra_state_attributes["underlying_climate_1"] = self._underlyings[
|
||||
0
|
||||
].entity_id
|
||||
self._attr_extra_state_attributes["underlying_climate_1"] = self._underlyings[
|
||||
1
|
||||
].entity_id if len(self._underlyings) > 1 else None
|
||||
self._attr_extra_state_attributes["underlying_climate_2"] = self._underlyings[
|
||||
2
|
||||
].entity_id if len(self._underlyings) > 2 else None
|
||||
self._attr_extra_state_attributes["underlying_climate_3"] = self._underlyings[
|
||||
3
|
||||
].entity_id if len(self._underlyings) > 3 else None
|
||||
|
||||
self._attr_extra_state_attributes[
|
||||
"start_hvac_action_date"
|
||||
] = self._underlying_climate_start_hvac_action_date
|
||||
|
||||
Reference in New Issue