Add power_percent in over_switch for UI
This commit is contained in:
@@ -12,7 +12,7 @@ from .const import (
|
|||||||
CONF_HEATER_3,
|
CONF_HEATER_3,
|
||||||
CONF_HEATER_4,
|
CONF_HEATER_4,
|
||||||
CONF_INVERSE_SWITCH,
|
CONF_INVERSE_SWITCH,
|
||||||
overrides
|
overrides,
|
||||||
)
|
)
|
||||||
|
|
||||||
from .base_thermostat import BaseThermostat
|
from .base_thermostat import BaseThermostat
|
||||||
@@ -21,15 +21,29 @@ from .prop_algorithm import PropAlgorithm
|
|||||||
|
|
||||||
_LOGGER = logging.getLogger(__name__)
|
_LOGGER = logging.getLogger(__name__)
|
||||||
|
|
||||||
|
|
||||||
class ThermostatOverSwitch(BaseThermostat):
|
class ThermostatOverSwitch(BaseThermostat):
|
||||||
"""Representation of a base class for a Versatile Thermostat over a switch."""
|
"""Representation of a base class for a Versatile Thermostat over a switch."""
|
||||||
|
|
||||||
_entity_component_unrecorded_attributes = BaseThermostat._entity_component_unrecorded_attributes.union(frozenset(
|
_entity_component_unrecorded_attributes = (
|
||||||
{
|
BaseThermostat._entity_component_unrecorded_attributes.union(
|
||||||
"is_over_switch", "underlying_switch_0", "underlying_switch_1",
|
frozenset(
|
||||||
"underlying_switch_2", "underlying_switch_3", "on_time_sec", "off_time_sec",
|
{
|
||||||
"cycle_min", "function", "tpi_coef_int", "tpi_coef_ext"
|
"is_over_switch",
|
||||||
}))
|
"underlying_switch_0",
|
||||||
|
"underlying_switch_1",
|
||||||
|
"underlying_switch_2",
|
||||||
|
"underlying_switch_3",
|
||||||
|
"on_time_sec",
|
||||||
|
"off_time_sec",
|
||||||
|
"cycle_min",
|
||||||
|
"function",
|
||||||
|
"tpi_coef_int",
|
||||||
|
"tpi_coef_ext",
|
||||||
|
}
|
||||||
|
)
|
||||||
|
)
|
||||||
|
)
|
||||||
|
|
||||||
# useless for now
|
# useless for now
|
||||||
# def __init__(self, hass: HomeAssistant, unique_id, name, entry_infos) -> None:
|
# def __init__(self, hass: HomeAssistant, unique_id, name, entry_infos) -> None:
|
||||||
@@ -39,17 +53,25 @@ class ThermostatOverSwitch(BaseThermostat):
|
|||||||
|
|
||||||
@property
|
@property
|
||||||
def is_over_switch(self) -> bool:
|
def is_over_switch(self) -> bool:
|
||||||
""" True if the Thermostat is over_switch"""
|
"""True if the Thermostat is over_switch"""
|
||||||
return True
|
return True
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def is_inversed(self) -> bool:
|
def is_inversed(self) -> bool:
|
||||||
""" True if the switch is inversed (for pilot wire and diode)"""
|
"""True if the switch is inversed (for pilot wire and diode)"""
|
||||||
return self._is_inversed is True
|
return self._is_inversed is True
|
||||||
|
|
||||||
|
@property
|
||||||
|
def power_percent(self) -> float | None:
|
||||||
|
"""Get the current on_percent value"""
|
||||||
|
if self._prop_algorithm:
|
||||||
|
return round(self._prop_algorithm.on_percent * 100, 0)
|
||||||
|
else:
|
||||||
|
return None
|
||||||
|
|
||||||
@overrides
|
@overrides
|
||||||
def post_init(self, entry_infos):
|
def post_init(self, entry_infos):
|
||||||
""" Initialize the Thermostat"""
|
"""Initialize the Thermostat"""
|
||||||
|
|
||||||
super().post_init(entry_infos)
|
super().post_init(entry_infos)
|
||||||
|
|
||||||
@@ -96,31 +118,32 @@ class ThermostatOverSwitch(BaseThermostat):
|
|||||||
async_track_state_change_event(
|
async_track_state_change_event(
|
||||||
self.hass, [switch.entity_id], self._async_switch_changed
|
self.hass, [switch.entity_id], self._async_switch_changed
|
||||||
)
|
)
|
||||||
)
|
)
|
||||||
|
|
||||||
self.hass.create_task(self.async_control_heating())
|
self.hass.create_task(self.async_control_heating())
|
||||||
|
|
||||||
@overrides
|
@overrides
|
||||||
def update_custom_attributes(self):
|
def update_custom_attributes(self):
|
||||||
""" Custom attributes """
|
"""Custom attributes"""
|
||||||
super().update_custom_attributes()
|
super().update_custom_attributes()
|
||||||
|
|
||||||
self._attr_extra_state_attributes["is_over_switch"] = self.is_over_switch
|
self._attr_extra_state_attributes["is_over_switch"] = self.is_over_switch
|
||||||
self._attr_extra_state_attributes["underlying_switch_0"] = (
|
self._attr_extra_state_attributes["underlying_switch_0"] = self._underlyings[
|
||||||
self._underlyings[0].entity_id)
|
0
|
||||||
|
].entity_id
|
||||||
self._attr_extra_state_attributes["underlying_switch_1"] = (
|
self._attr_extra_state_attributes["underlying_switch_1"] = (
|
||||||
self._underlyings[1].entity_id if len(self._underlyings) > 1 else None
|
self._underlyings[1].entity_id if len(self._underlyings) > 1 else None
|
||||||
)
|
)
|
||||||
self._attr_extra_state_attributes["underlying_switch_2"] = (
|
self._attr_extra_state_attributes["underlying_switch_2"] = (
|
||||||
self._underlyings[2].entity_id if len(self._underlyings) > 2 else None
|
self._underlyings[2].entity_id if len(self._underlyings) > 2 else None
|
||||||
)
|
)
|
||||||
self._attr_extra_state_attributes["underlying_switch_3"] = (
|
self._attr_extra_state_attributes["underlying_switch_3"] = (
|
||||||
self._underlyings[3].entity_id if len(self._underlyings) > 3 else None
|
self._underlyings[3].entity_id if len(self._underlyings) > 3 else None
|
||||||
)
|
)
|
||||||
|
|
||||||
self._attr_extra_state_attributes[
|
self._attr_extra_state_attributes[
|
||||||
"on_percent"
|
"on_percent"
|
||||||
] = self._prop_algorithm.on_percent
|
] = self._prop_algorithm.on_percent
|
||||||
self._attr_extra_state_attributes[
|
self._attr_extra_state_attributes[
|
||||||
"on_time_sec"
|
"on_time_sec"
|
||||||
] = self._prop_algorithm.on_time_sec
|
] = self._prop_algorithm.on_time_sec
|
||||||
|
|||||||
Reference in New Issue