Issue #524 switch from cool to heat don't change the target temp (#529)

* Preparation tests ok

* Fixed

---------

Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
Jean-Marc Collin
2024-10-08 17:06:16 +02:00
committed by GitHub
parent 668053b352
commit 70f91f3cbe
7 changed files with 138 additions and 36 deletions

View File

@@ -1235,7 +1235,7 @@ class BaseThermostat(ClimateEntity, RestoreEntity, Generic[T]):
)
# If AC is on maybe we have to change the temperature in force mode, but not in frost mode (there is no Frost protection possible in AC mode)
if self._hvac_mode == HVACMode.COOL and self.preset_mode != PRESET_NONE:
if self._hvac_mode in [HVACMode.COOL, HVACMode.HEAT, HVACMode.HEAT_COOL] and self.preset_mode != PRESET_NONE:
if self.preset_mode != PRESET_FROST_PROTECTION:
await self._async_set_preset_mode_internal(self.preset_mode, True)
else: