Issue #162 - overpowering mode after preset change
This commit is contained in:
@@ -163,7 +163,9 @@ async def test_one_switch_cycle(
|
||||
# assert entity.underlying_entity(0)._should_relaunch_control_heating is True
|
||||
|
||||
# Simulate the relaunch
|
||||
await entity.underlying_entity(0)._turn_on_later( # pylint: disable=protected-access
|
||||
await entity.underlying_entity(
|
||||
0
|
||||
)._turn_on_later( # pylint: disable=protected-access
|
||||
None
|
||||
)
|
||||
# wait restart
|
||||
@@ -184,7 +186,9 @@ async def test_one_switch_cycle(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.is_device_active",
|
||||
return_value=True,
|
||||
) as mock_device_active:
|
||||
await entity.underlying_entity(0)._turn_off_later( # pylint: disable=protected-access
|
||||
await entity.underlying_entity(
|
||||
0
|
||||
)._turn_off_later( # pylint: disable=protected-access
|
||||
None
|
||||
)
|
||||
|
||||
@@ -207,7 +211,9 @@ async def test_one_switch_cycle(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.is_device_active",
|
||||
return_value=True,
|
||||
) as mock_device_active:
|
||||
await entity.underlying_entity(0)._turn_on_later( # pylint: disable=protected-access
|
||||
await entity.underlying_entity(
|
||||
0
|
||||
)._turn_on_later( # pylint: disable=protected-access
|
||||
None
|
||||
)
|
||||
|
||||
@@ -591,3 +597,139 @@ async def test_multiple_climates_underlying_changes(
|
||||
assert entity.hvac_mode == HVACMode.HEAT
|
||||
assert entity.hvac_action == HVACAction.IDLE
|
||||
assert entity.is_device_active is False # pylint: disable=protected-access
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
@pytest.mark.parametrize("expected_lingering_timers", [True])
|
||||
async def test_multiple_switch_power_management(
|
||||
hass: HomeAssistant, skip_hass_states_is_state
|
||||
):
|
||||
"""Test the Power management"""
|
||||
|
||||
entry = MockConfigEntry(
|
||||
domain=DOMAIN,
|
||||
title="TheOverSwitchMockName",
|
||||
unique_id="uniqueId",
|
||||
data={
|
||||
CONF_NAME: "TheOver4SwitchMockName",
|
||||
CONF_THERMOSTAT_TYPE: CONF_THERMOSTAT_SWITCH,
|
||||
CONF_TEMP_SENSOR: "sensor.mock_temp_sensor",
|
||||
CONF_EXTERNAL_TEMP_SENSOR: "sensor.mock_ext_temp_sensor",
|
||||
CONF_CYCLE_MIN: 8,
|
||||
CONF_TEMP_MIN: 15,
|
||||
CONF_TEMP_MAX: 30,
|
||||
"eco_temp": 17,
|
||||
"comfort_temp": 18,
|
||||
"boost_temp": 19,
|
||||
CONF_USE_WINDOW_FEATURE: False,
|
||||
CONF_USE_MOTION_FEATURE: False,
|
||||
CONF_USE_POWER_FEATURE: True,
|
||||
CONF_USE_PRESENCE_FEATURE: False,
|
||||
CONF_HEATER: "switch.mock_switch1",
|
||||
CONF_HEATER_2: "switch.mock_switch2",
|
||||
CONF_HEATER_3: "switch.mock_switch3",
|
||||
CONF_HEATER_4: "switch.mock_switch4",
|
||||
CONF_MINIMAL_ACTIVATION_DELAY: 30,
|
||||
CONF_SECURITY_DELAY_MIN: 5,
|
||||
CONF_SECURITY_MIN_ON_PERCENT: 0.3,
|
||||
CONF_PROP_FUNCTION: PROPORTIONAL_FUNCTION_TPI,
|
||||
CONF_TPI_COEF_INT: 0.3,
|
||||
CONF_TPI_COEF_EXT: 0.01,
|
||||
CONF_POWER_SENSOR: "sensor.mock_power_sensor",
|
||||
CONF_MAX_POWER_SENSOR: "sensor.mock_power_max_sensor",
|
||||
CONF_DEVICE_POWER: 100,
|
||||
CONF_PRESET_POWER: 12,
|
||||
},
|
||||
)
|
||||
|
||||
entity: BaseThermostat = await create_thermostat(
|
||||
hass, entry, "climate.theover4switchmockname"
|
||||
)
|
||||
assert entity
|
||||
assert entity.is_over_climate is False
|
||||
assert entity.nb_underlying_entities == 4
|
||||
|
||||
tpi_algo = entity._prop_algorithm
|
||||
assert tpi_algo
|
||||
|
||||
await entity.async_set_hvac_mode(HVACMode.HEAT)
|
||||
await entity.async_set_preset_mode(PRESET_BOOST)
|
||||
assert entity.hvac_mode is HVACMode.HEAT
|
||||
assert entity.preset_mode is PRESET_BOOST
|
||||
assert entity.overpowering_state is None
|
||||
assert entity.target_temperature == 19
|
||||
|
||||
# 1. Send power mesurement
|
||||
await send_power_change_event(entity, 50, datetime.now())
|
||||
# Send power max mesurement
|
||||
await send_max_power_change_event(entity, 300, datetime.now())
|
||||
assert await entity.check_overpowering() is False
|
||||
# All configuration is complete and power is < power_max
|
||||
assert entity.preset_mode is PRESET_BOOST
|
||||
assert entity.overpowering_state is False
|
||||
|
||||
# 2. Send power max mesurement too low and HVACMode is on
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
|
||||
) as mock_heater_on, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
|
||||
) as mock_heater_off:
|
||||
# 100 of the device / 4 -> 25, current power 50 so max is 75
|
||||
await send_max_power_change_event(entity, 74, datetime.now())
|
||||
assert await entity.check_overpowering() is True
|
||||
# All configuration is complete and power is > power_max we switch to POWER preset
|
||||
assert entity.preset_mode is PRESET_POWER
|
||||
assert entity.overpowering_state is True
|
||||
assert entity.target_temperature == 12
|
||||
|
||||
assert mock_send_event.call_count == 2
|
||||
mock_send_event.assert_has_calls(
|
||||
[
|
||||
call.send_event(EventType.PRESET_EVENT, {"preset": PRESET_POWER}),
|
||||
call.send_event(
|
||||
EventType.POWER_EVENT,
|
||||
{
|
||||
"type": "start",
|
||||
"current_power": 50,
|
||||
"device_power": 100,
|
||||
"current_power_max": 74,
|
||||
"current_power_consumption": 25.0,
|
||||
},
|
||||
),
|
||||
],
|
||||
any_order=True,
|
||||
)
|
||||
assert mock_heater_on.call_count == 0
|
||||
assert mock_heater_off.call_count == 4 # The fourth are shutdown
|
||||
|
||||
# 3. change PRESET
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event:
|
||||
await entity.async_set_preset_mode(PRESET_ECO)
|
||||
assert entity.preset_mode is PRESET_ECO
|
||||
# No change
|
||||
assert entity.overpowering_state is True
|
||||
|
||||
# 4. Send hugh power max mesurement to release overpowering
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
|
||||
) as mock_heater_on, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_off"
|
||||
) as mock_heater_off:
|
||||
# 100 of the device / 4 -> 25, current power 50 so max is 75. With 150 no overheating
|
||||
await send_max_power_change_event(entity, 150, datetime.now())
|
||||
assert await entity.check_overpowering() is False
|
||||
# All configuration is complete and power is > power_max we switch to POWER preset
|
||||
assert entity.preset_mode is PRESET_ECO
|
||||
assert entity.overpowering_state is False
|
||||
assert entity.target_temperature == 17
|
||||
|
||||
assert (
|
||||
mock_heater_on.call_count == 0
|
||||
) # The fourth are not restarted because temperature is enought
|
||||
assert mock_heater_off.call_count == 0
|
||||
|
||||
Reference in New Issue