@@ -259,21 +259,6 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
if not self.check_valve_regulation_nb_entities(data, step_id):
|
||||
raise ValveRegulationNbEntitiesIncorrect()
|
||||
|
||||
# Check that the min_opening_degrees is correctly set
|
||||
raw_list = data.get(CONF_MIN_OPENING_DEGREES, None)
|
||||
if raw_list:
|
||||
try:
|
||||
# Validation : Convertir la liste saisie
|
||||
int_list = [int(x.strip()) for x in raw_list.split(",")]
|
||||
|
||||
# Optionnel : Vérifiez des conditions supplémentaires sur la liste
|
||||
if any(x < 0 for x in int_list):
|
||||
raise ValueError
|
||||
except ValueError as exc:
|
||||
raise ValveRegulationMinOpeningDegreesIncorrect(
|
||||
CONF_MIN_OPENING_DEGREES
|
||||
) from exc
|
||||
|
||||
def check_config_complete(self, infos) -> bool:
|
||||
"""True if the config is now complete (ie all mandatory attributes are set)"""
|
||||
is_central_config = (
|
||||
@@ -414,8 +399,6 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
||||
errors["base"] = "configuration_not_complete"
|
||||
except ValveRegulationNbEntitiesIncorrect as err:
|
||||
errors["base"] = "valve_regulation_nb_entities_incorrect"
|
||||
except ValveRegulationMinOpeningDegreesIncorrect as err:
|
||||
errors[str(err)] = "min_opening_degrees_format"
|
||||
except Exception: # pylint: disable=broad-except
|
||||
_LOGGER.exception("Unexpected exception")
|
||||
errors["base"] = "unknown"
|
||||
|
||||
@@ -219,7 +219,6 @@ STEP_VALVE_REGULATION = vol.Schema( # pylint: disable=invalid-name
|
||||
PROPORTIONAL_FUNCTION_TPI,
|
||||
]
|
||||
),
|
||||
vol.Optional(CONF_MIN_OPENING_DEGREES, default=""): str,
|
||||
}
|
||||
)
|
||||
|
||||
|
||||
@@ -123,7 +123,6 @@ CONF_STEP_TEMPERATURE = "step_temperature"
|
||||
CONF_OFFSET_CALIBRATION_LIST = "offset_calibration_entity_ids"
|
||||
CONF_OPENING_DEGREE_LIST = "opening_degree_entity_ids"
|
||||
CONF_CLOSING_DEGREE_LIST = "closing_degree_entity_ids"
|
||||
CONF_MIN_OPENING_DEGREES = "min_opening_degrees"
|
||||
|
||||
# Deprecated
|
||||
CONF_HEATER = "heater_entity_id"
|
||||
@@ -553,10 +552,6 @@ class ValveRegulationNbEntitiesIncorrect(HomeAssistantError):
|
||||
The number of specific entities is incorrect."""
|
||||
|
||||
|
||||
class ValveRegulationMinOpeningDegreesIncorrect(HomeAssistantError):
|
||||
"""Error to indicate that the minimal opening degrees is not a list of int separated by coma"""
|
||||
|
||||
|
||||
class overrides: # pylint: disable=invalid-name
|
||||
"""An annotation to inform overrides"""
|
||||
|
||||
|
||||
@@ -224,15 +224,13 @@
|
||||
"offset_calibration_entity_ids": "Offset calibration entities",
|
||||
"opening_degree_entity_ids": "Opening degree entities",
|
||||
"closing_degree_entity_ids": "Closing degree entities",
|
||||
"proportional_function": "Algorithm",
|
||||
"min_opening_degrees": "Min opening degrees"
|
||||
"proportional_function": "Algorithm"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"min_opening_degrees": "A comma seperated list of minimal opening degrees. Default to 0. Example: 20, 25, 30"
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)"
|
||||
}
|
||||
}
|
||||
},
|
||||
@@ -470,15 +468,13 @@
|
||||
"offset_calibration_entity_ids": "Offset calibration entities",
|
||||
"opening_degree_entity_ids": "Opening degree entities",
|
||||
"closing_degree_entity_ids": "Closing degree entities",
|
||||
"proportional_function": "Algorithm",
|
||||
"min_opening_degrees": "Min opening degrees"
|
||||
"proportional_function": "Algorithm"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"min_opening_degrees": "A comma seperated list of minimal opening degrees. Default to 0. Example: 20, 25, 30"
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)"
|
||||
}
|
||||
}
|
||||
},
|
||||
@@ -488,8 +484,7 @@
|
||||
"window_open_detection_method": "Only one window open detection method should be used. Use either window sensor or automatic detection through temperature threshold but not both",
|
||||
"no_central_config": "You cannot check 'use central configuration' because no central configuration was found. You need to create a Versatile Thermostat of type 'Central Configuration' to use it.",
|
||||
"service_configuration_format": "The format of the service configuration is wrong",
|
||||
"valve_regulation_nb_entities_incorrect": "The number of valve entities for valve regulation should be equal to the number of underlyings",
|
||||
"min_opening_degrees_format": "A comma separated list of positive integer is expected. Example: 20, 25, 30"
|
||||
"valve_regulation_nb_entities_incorrect": "The number of valve entities for valve regulation should be equal to the number of underlyings"
|
||||
},
|
||||
"abort": {
|
||||
"already_configured": "Device is already configured"
|
||||
|
||||
@@ -37,7 +37,6 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
|
||||
"tpi_coef_int",
|
||||
"tpi_coef_ext",
|
||||
"power_percent",
|
||||
"min_opening_degrees",
|
||||
}
|
||||
)
|
||||
)
|
||||
@@ -52,7 +51,6 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
|
||||
self._last_calculation_timestamp: datetime | None = None
|
||||
self._auto_regulation_dpercent: float | None = None
|
||||
self._auto_regulation_period_min: int | None = None
|
||||
self._min_opening_degress: list[int] = []
|
||||
|
||||
super().__init__(hass, unique_id, name, entry_infos)
|
||||
|
||||
@@ -88,14 +86,6 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
|
||||
offset_list = config_entry.get(CONF_OFFSET_CALIBRATION_LIST, [])
|
||||
opening_list = config_entry.get(CONF_OPENING_DEGREE_LIST)
|
||||
closing_list = config_entry.get(CONF_CLOSING_DEGREE_LIST, [])
|
||||
|
||||
self._min_opening_degrees = config_entry.get(CONF_MIN_OPENING_DEGREES, None)
|
||||
min_opening_degrees_list = []
|
||||
if self._min_opening_degrees:
|
||||
min_opening_degrees_list = [
|
||||
int(x.strip()) for x in self._min_opening_degrees.split(",")
|
||||
]
|
||||
|
||||
for idx, _ in enumerate(config_entry.get(CONF_UNDERLYING_LIST)):
|
||||
offset = offset_list[idx] if idx < len(offset_list) else None
|
||||
# number of opening should equal number of underlying
|
||||
@@ -108,11 +98,6 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
|
||||
opening_degree_entity_id=opening,
|
||||
closing_degree_entity_id=closing,
|
||||
climate_underlying=self._underlyings[idx],
|
||||
min_opening_degree=(
|
||||
min_opening_degrees_list[idx]
|
||||
if idx < len(min_opening_degrees_list)
|
||||
else 0
|
||||
),
|
||||
)
|
||||
self._underlyings_valve_regulation.append(under)
|
||||
|
||||
@@ -145,10 +130,6 @@ class ThermostatOverClimateValve(ThermostatOverClimate):
|
||||
self._attr_extra_state_attributes["tpi_coef_int"] = self._tpi_coef_int
|
||||
self._attr_extra_state_attributes["tpi_coef_ext"] = self._tpi_coef_ext
|
||||
|
||||
self._attr_extra_state_attributes["min_opening_degrees"] = (
|
||||
self._min_opening_degrees
|
||||
)
|
||||
|
||||
self._attr_extra_state_attributes["valve_open_percent"] = (
|
||||
self.valve_open_percent
|
||||
)
|
||||
|
||||
@@ -224,15 +224,13 @@
|
||||
"offset_calibration_entity_ids": "Offset calibration entities",
|
||||
"opening_degree_entity_ids": "Opening degree entities",
|
||||
"closing_degree_entity_ids": "Closing degree entities",
|
||||
"proportional_function": "Algorithm",
|
||||
"min_opening_degrees": "Min opening degrees"
|
||||
"proportional_function": "Algorithm"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"min_opening_degrees": "A comma seperated list of minimal opening degrees. Default to 0. Example: 20, 25, 30"
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)"
|
||||
}
|
||||
}
|
||||
},
|
||||
@@ -470,15 +468,13 @@
|
||||
"offset_calibration_entity_ids": "Offset calibration entities",
|
||||
"opening_degree_entity_ids": "Opening degree entities",
|
||||
"closing_degree_entity_ids": "Closing degree entities",
|
||||
"proportional_function": "Algorithm",
|
||||
"min_opening_degrees": "Min opening degrees"
|
||||
"proportional_function": "Algorithm"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "The list of the 'offset calibration' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"opening_degree_entity_ids": "The list of the 'opening degree' entities. There should be one per underlying climate entities",
|
||||
"closing_degree_entity_ids": "The list of the 'closing degree' entities. Set it if your TRV have the entity for better regulation. There should be one per underlying climate entities",
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)",
|
||||
"min_opening_degrees": "A comma seperated list of minimal opening degrees. Default to 0. Example: 20, 25, 30"
|
||||
"proportional_function": "Algorithm to use (TPI is the only one for now)"
|
||||
}
|
||||
}
|
||||
},
|
||||
|
||||
@@ -224,15 +224,13 @@
|
||||
"offset_calibration_entity_ids": "Entités de 'calibrage du décalage''",
|
||||
"opening_degree_entity_ids": "Entités 'ouverture de vanne'",
|
||||
"closing_degree_entity_ids": "Entités 'fermeture de la vanne'",
|
||||
"proportional_function": "Algorithme",
|
||||
"min_opening_degrees": "Ouvertures minimales"
|
||||
"proportional_function": "Algorithme"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "La liste des entités 'calibrage du décalage' (offset calibration). Configurez le si votre TRV possède cette fonction pour une meilleure régulation. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"opening_degree_entity_ids": "La liste des entités 'ouverture de vanne'. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"closing_degree_entity_ids": "La liste des entités 'fermeture de la vanne'. Configurez le si votre TRV possède cette fonction pour une meilleure régulation. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"proportional_function": "Algorithme à utiliser (seulement TPI est disponible)",
|
||||
"min_opening_degrees": "Une liste séparée par des virgules de minimum d'ouverture. Valeur par défaut : 0. Exemple : 20, 25, 30"
|
||||
"proportional_function": "Algorithme à utiliser (seulement TPI est disponible)"
|
||||
}
|
||||
}
|
||||
},
|
||||
@@ -464,15 +462,13 @@
|
||||
"offset_calibration_entity_ids": "Entités de 'calibrage du décalage''",
|
||||
"opening_degree_entity_ids": "Entités 'ouverture de vanne'",
|
||||
"closing_degree_entity_ids": "Entités 'fermeture de la vanne'",
|
||||
"proportional_function": "Algorithme",
|
||||
"min_opening_degrees": "Ouvertures minimales"
|
||||
"proportional_function": "Algorithme"
|
||||
},
|
||||
"data_description": {
|
||||
"offset_calibration_entity_ids": "La liste des entités 'calibrage du décalage' (offset calibration). Configurez le si votre TRV possède cette fonction pour une meilleure régulation. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"opening_degree_entity_ids": "La liste des entités 'ouverture de vanne'. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"closing_degree_entity_ids": "La liste des entités 'fermeture de la vanne'. Configurez le si votre TRV possède cette fonction pour une meilleure régulation. Il doit y en avoir une par entité climate sous-jacente",
|
||||
"proportional_function": "Algorithme à utiliser (seulement TPI est disponible)",
|
||||
"min_opening_degrees": "Une liste séparée par des virgules de minimum d'ouverture. Valeur par défaut : 0. Exemple : 20, 25, 30"
|
||||
"proportional_function": "Algorithme à utiliser (seulement TPI est disponible)"
|
||||
}
|
||||
}
|
||||
},
|
||||
@@ -482,8 +478,7 @@
|
||||
"window_open_detection_method": "Une seule méthode de détection des ouvertures ouvertes doit être utilisée. Utilisez le détecteur d'ouverture ou les seuils de température mais pas les deux.",
|
||||
"no_central_config": "Vous ne pouvez pas cocher 'Utiliser la configuration centrale' car aucune configuration centrale n'a été trouvée. Vous devez créer un Versatile Thermostat de type 'Central Configuration' pour pouvoir l'utiliser.",
|
||||
"service_configuration_format": "Mauvais format de la configuration du service",
|
||||
"valve_regulation_nb_entities_incorrect": "Le nombre d'entités pour la régulation par vanne doit être égal au nombre d'entité sous-jacentes",
|
||||
"min_opening_degrees_format": "Une liste d'entiers positifs séparés par des ',' est attendu. Exemple : 20, 25, 30"
|
||||
"valve_regulation_nb_entities_incorrect": "Le nombre d'entités pour la régulation par vanne doit être égal au nombre d'entité sous-jacentes"
|
||||
},
|
||||
"abort": {
|
||||
"already_configured": "Le device est déjà configuré"
|
||||
|
||||
@@ -1029,7 +1029,6 @@ class UnderlyingValveRegulation(UnderlyingValve):
|
||||
opening_degree_entity_id: str,
|
||||
closing_degree_entity_id: str,
|
||||
climate_underlying: UnderlyingClimate,
|
||||
min_opening_degree: int = 0,
|
||||
) -> None:
|
||||
"""Initialize the underlying TRV with valve regulation"""
|
||||
super().__init__(
|
||||
@@ -1046,7 +1045,6 @@ class UnderlyingValveRegulation(UnderlyingValve):
|
||||
self._max_opening_degree: float = None
|
||||
self._min_offset_calibration: float = None
|
||||
self._max_offset_calibration: float = None
|
||||
self._min_opening_degree: int = min_opening_degree
|
||||
|
||||
async def send_percent_open(self):
|
||||
"""Send the percent open to the underlying valve"""
|
||||
@@ -1081,9 +1079,6 @@ class UnderlyingValveRegulation(UnderlyingValve):
|
||||
return
|
||||
|
||||
# Send opening_degree
|
||||
if 0 < self._percent_open < self._min_opening_degree:
|
||||
self._percent_open = self._min_opening_degree
|
||||
|
||||
await super().send_percent_open()
|
||||
|
||||
# Send closing_degree if set
|
||||
@@ -1143,11 +1138,6 @@ class UnderlyingValveRegulation(UnderlyingValve):
|
||||
"""The offset_calibration_entity_id"""
|
||||
return self._closing_degree_entity_id
|
||||
|
||||
@property
|
||||
def min_opening_degree(self) -> int:
|
||||
"""The minimum opening degree"""
|
||||
return self._min_opening_degree
|
||||
|
||||
@property
|
||||
def have_closing_degree_entity(self) -> bool:
|
||||
"""Return True if the underlying have a closing_degree entity"""
|
||||
|
||||
Reference in New Issue