Feature 131 control trv valve (#139)
* Add configFlow and translations * Refacto VersatileThermostat with BaseThermostat. Tests ok * Add ThermostatValve. All tests ok --------- Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
@@ -58,7 +58,7 @@ async def test_one_switch_cycle(
|
||||
|
||||
# start heating, in boost mode. We block the control_heating to avoid running a cycle
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat._async_control_heating"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.async_control_heating"
|
||||
):
|
||||
await entity.async_set_hvac_mode(HVACMode.HEAT)
|
||||
await entity.async_set_preset_mode(PRESET_BOOST)
|
||||
@@ -75,14 +75,14 @@ async def test_one_switch_cycle(
|
||||
with patch(
|
||||
"homeassistant.core.StateMachine.is_state", return_value=False
|
||||
) as mock_is_state:
|
||||
assert entity._is_device_active is False # pylint: disable=protected-access
|
||||
assert entity.is_device_active is False # pylint: disable=protected-access
|
||||
|
||||
# Should be call for the Switch
|
||||
assert mock_is_state.call_count == 1
|
||||
|
||||
# Set temperature to a low level
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
|
||||
) as mock_heater_on, patch(
|
||||
@@ -117,7 +117,7 @@ async def test_one_switch_cycle(
|
||||
# Set a temperature at middle level
|
||||
event_timestamp = now - timedelta(minutes=4)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
|
||||
) as mock_heater_on, patch(
|
||||
@@ -139,7 +139,7 @@ async def test_one_switch_cycle(
|
||||
# Set another temperature at middle level
|
||||
event_timestamp = now - timedelta(minutes=3)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
|
||||
) as mock_heater_on, patch(
|
||||
@@ -172,7 +172,7 @@ async def test_one_switch_cycle(
|
||||
# Simulate the end of heater on cycle
|
||||
event_timestamp = now - timedelta(minutes=3)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
|
||||
) as mock_heater_on, patch(
|
||||
@@ -195,7 +195,7 @@ async def test_one_switch_cycle(
|
||||
# Simulate the start of heater on cycle
|
||||
event_timestamp = now - timedelta(minutes=3)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
|
||||
) as mock_heater_on, patch(
|
||||
@@ -269,7 +269,7 @@ async def test_multiple_switchs(
|
||||
|
||||
# start heating, in boost mode. We block the control_heating to avoid running a cycle
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat._async_control_heating"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.async_control_heating"
|
||||
), patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.set_hvac_mode"
|
||||
) as mock_underlying_set_hvac_mode:
|
||||
@@ -285,7 +285,7 @@ async def test_multiple_switchs(
|
||||
await send_temperature_change_event(entity, 15, event_timestamp)
|
||||
|
||||
# Checks that all climates are off
|
||||
assert entity._is_device_active is False # pylint: disable=protected-access
|
||||
assert entity.is_device_active is False # pylint: disable=protected-access
|
||||
|
||||
# Should be call for all Switch
|
||||
assert mock_underlying_set_hvac_mode.call_count == 4
|
||||
@@ -297,7 +297,7 @@ async def test_multiple_switchs(
|
||||
|
||||
# Set temperature to a low level
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
|
||||
) as mock_heater_on, patch(
|
||||
@@ -335,7 +335,7 @@ async def test_multiple_switchs(
|
||||
# Set a temperature at middle level
|
||||
event_timestamp = now - timedelta(minutes=4)
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat.send_event"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.send_event"
|
||||
) as mock_send_event, patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingSwitch.turn_on"
|
||||
) as mock_heater_on, patch(
|
||||
@@ -405,7 +405,7 @@ async def test_multiple_climates(
|
||||
|
||||
# start heating, in boost mode. We block the control_heating to avoid running a cycle
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat._async_control_heating"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.async_control_heating"
|
||||
), patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.set_hvac_mode"
|
||||
) as mock_underlying_set_hvac_mode:
|
||||
@@ -427,11 +427,11 @@ async def test_multiple_climates(
|
||||
call.set_hvac_mode(HVACMode.HEAT),
|
||||
]
|
||||
)
|
||||
assert entity._is_device_active is False # pylint: disable=protected-access
|
||||
assert entity.is_device_active is False # pylint: disable=protected-access
|
||||
|
||||
# Stop heating, in boost mode. We block the control_heating to avoid running a cycle
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat._async_control_heating"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.async_control_heating"
|
||||
), patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.set_hvac_mode"
|
||||
) as mock_underlying_set_hvac_mode:
|
||||
@@ -452,7 +452,7 @@ async def test_multiple_climates(
|
||||
call.set_hvac_mode(HVACMode.OFF),
|
||||
]
|
||||
)
|
||||
assert entity._is_device_active is False # pylint: disable=protected-access
|
||||
assert entity.is_device_active is False # pylint: disable=protected-access
|
||||
|
||||
|
||||
@pytest.mark.parametrize("expected_lingering_tasks", [True])
|
||||
@@ -505,7 +505,7 @@ async def test_multiple_climates_underlying_changes(
|
||||
|
||||
# start heating, in boost mode. We block the control_heating to avoid running a cycle
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat._async_control_heating"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.async_control_heating"
|
||||
), patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.set_hvac_mode"
|
||||
) as mock_underlying_set_hvac_mode:
|
||||
@@ -527,11 +527,11 @@ async def test_multiple_climates_underlying_changes(
|
||||
call.set_hvac_mode(HVACMode.HEAT),
|
||||
]
|
||||
)
|
||||
assert entity._is_device_active is False # pylint: disable=protected-access
|
||||
assert entity.is_device_active is False # pylint: disable=protected-access
|
||||
|
||||
# Stop heating on one underlying climate
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat._async_control_heating"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.async_control_heating"
|
||||
), patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.set_hvac_mode"
|
||||
) as mock_underlying_set_hvac_mode:
|
||||
@@ -554,11 +554,11 @@ async def test_multiple_climates_underlying_changes(
|
||||
]
|
||||
)
|
||||
assert entity.hvac_mode == HVACMode.OFF
|
||||
assert entity._is_device_active is False # pylint: disable=protected-access
|
||||
assert entity.is_device_active is False # pylint: disable=protected-access
|
||||
|
||||
# Start heating on one underlying climate
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.climate.VersatileThermostat._async_control_heating"
|
||||
"custom_components.versatile_thermostat.base_thermostat.BaseThermostat.async_control_heating"
|
||||
), patch(
|
||||
"custom_components.versatile_thermostat.underlyings.UnderlyingClimate.set_hvac_mode"
|
||||
) as mock_underlying_set_hvac_mode, patch(
|
||||
@@ -587,4 +587,4 @@ async def test_multiple_climates_underlying_changes(
|
||||
)
|
||||
assert entity.hvac_mode == HVACMode.HEAT
|
||||
assert entity.hvac_action == HVACAction.IDLE
|
||||
assert entity._is_device_active is False # pylint: disable=protected-access
|
||||
assert entity.is_device_active is False # pylint: disable=protected-access
|
||||
|
||||
Reference in New Issue