Issue 348 self regulation use internal temp (#373)
* Add config option * With all features + testu ok * Change algo using underlying internal temp * Algo fixes * Bières ! * Change reset cumulated_error formula * FIX pi algo test with accumulated_error reset --------- Co-authored-by: Jean-Marc Collin <jean-marc.collin-extern@renault.com>
This commit is contained in:
@@ -1233,9 +1233,9 @@ class BaseThermostat(ClimateEntity, RestoreEntity):
|
||||
)
|
||||
|
||||
# If AC is on maybe we have to change the temperature in force mode, but not in frost mode (there is no Frost protection possible in AC mode)
|
||||
if self._hvac_mode == HVACMode.COOL:
|
||||
if self._hvac_mode == HVACMode.COOL and self.preset_mode != PRESET_NONE:
|
||||
if self.preset_mode != PRESET_FROST_PROTECTION:
|
||||
await self._async_set_preset_mode_internal(self._attr_preset_mode, True)
|
||||
await self._async_set_preset_mode_internal(self.preset_mode, True)
|
||||
else:
|
||||
await self._async_set_preset_mode_internal(PRESET_ECO, True, False)
|
||||
|
||||
|
||||
@@ -144,6 +144,7 @@ STEP_THERMOSTAT_CLIMATE = vol.Schema( # pylint: disable=invalid-name
|
||||
mode="dropdown",
|
||||
)
|
||||
),
|
||||
vol.Optional(CONF_AUTO_REGULATION_USE_DEVICE_TEMP, default=False): cv.boolean,
|
||||
}
|
||||
)
|
||||
|
||||
|
||||
@@ -106,6 +106,7 @@ CONF_AUTO_REGULATION_STRONG = "auto_regulation_strong"
|
||||
CONF_AUTO_REGULATION_EXPERT = "auto_regulation_expert"
|
||||
CONF_AUTO_REGULATION_DTEMP = "auto_regulation_dtemp"
|
||||
CONF_AUTO_REGULATION_PERIOD_MIN = "auto_regulation_periode_min"
|
||||
CONF_AUTO_REGULATION_USE_DEVICE_TEMP = "auto_regulation_use_device_temp"
|
||||
CONF_INVERSE_SWITCH = "inverse_switch_command"
|
||||
CONF_AUTO_FAN_MODE = "auto_fan_mode"
|
||||
CONF_AUTO_FAN_NONE = "auto_fan_none"
|
||||
@@ -257,6 +258,7 @@ ALL_CONF = (
|
||||
CONF_AUTO_REGULATION_MODE,
|
||||
CONF_AUTO_REGULATION_DTEMP,
|
||||
CONF_AUTO_REGULATION_PERIOD_MIN,
|
||||
CONF_AUTO_REGULATION_USE_DEVICE_TEMP,
|
||||
CONF_INVERSE_SWITCH,
|
||||
CONF_AUTO_FAN_MODE,
|
||||
CONF_USE_MAIN_CENTRAL_CONFIG,
|
||||
|
||||
@@ -47,16 +47,16 @@ class PITemperatureRegulator:
|
||||
def set_target_temp(self, target_temp):
|
||||
"""Set the new target_temp"""
|
||||
self.target_temp = target_temp
|
||||
# Do not reset the accumulated error
|
||||
# Discussion #191. After a target change we should reset the accumulated error which is certainly wrong now.
|
||||
if self.accumulated_error < 0:
|
||||
self.accumulated_error = 0
|
||||
# Discussion #384. Finally don't reset the accumulated error but smoothly reset it if the sign is inversed
|
||||
# if self.accumulated_error < 0:
|
||||
# self.accumulated_error = 0
|
||||
|
||||
def calculate_regulated_temperature(
|
||||
self, internal_temp: float, external_temp: float
|
||||
self, room_temp: float, external_temp: float
|
||||
): # pylint: disable=unused-argument
|
||||
"""Calculate a new target_temp given some temperature"""
|
||||
if internal_temp is None:
|
||||
if room_temp is None:
|
||||
_LOGGER.warning(
|
||||
"Temporarily skipping the self-regulation algorithm while the configured sensor for room temperature is unavailable"
|
||||
)
|
||||
@@ -68,9 +68,14 @@ class PITemperatureRegulator:
|
||||
return self.target_temp
|
||||
|
||||
# Calculate the error factor (P)
|
||||
error = self.target_temp - internal_temp
|
||||
error = self.target_temp - room_temp
|
||||
|
||||
# Calculate the sum of error (I)
|
||||
# Discussion #384. Finally don't reset the accumulated error but smoothly reset it if the sign is inversed
|
||||
# If the error have change its sign, reset smoothly the accumulated error
|
||||
if error * self.accumulated_error < 0:
|
||||
self.accumulated_error = self.accumulated_error / 2.0
|
||||
|
||||
self.accumulated_error += error
|
||||
|
||||
# Capping of the error
|
||||
@@ -83,19 +88,12 @@ class PITemperatureRegulator:
|
||||
offset = self.kp * error + self.ki * self.accumulated_error
|
||||
|
||||
# Calculate the exterior offset
|
||||
# For Maia tests - use the internal_temp vs external_temp and not target_temp - external_temp
|
||||
offset_ext = self.k_ext * (internal_temp - external_temp)
|
||||
offset_ext = self.k_ext * (room_temp - external_temp)
|
||||
|
||||
# Capping of offset_ext
|
||||
# Capping of offset
|
||||
total_offset = offset + offset_ext
|
||||
total_offset = min(self.offset_max, max(-self.offset_max, total_offset))
|
||||
|
||||
# If temperature is near the target_temp, reset the accumulated_error
|
||||
# Issue #199 - don't reset the accumulation error
|
||||
# if abs(error) < self.stabilization_threshold:
|
||||
# _LOGGER.debug("Stabilisation")
|
||||
# self.accumulated_error = 0
|
||||
|
||||
result = round(self.target_temp + total_offset, 1)
|
||||
|
||||
_LOGGER.debug(
|
||||
|
||||
@@ -60,6 +60,7 @@
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimal period",
|
||||
"auto_regulation_use_device_temp": "Use internal temperature of the underlying",
|
||||
"inverse_switch_command": "Inverse switch command",
|
||||
"auto_fan_mode": " Auto fan mode"
|
||||
},
|
||||
@@ -82,6 +83,7 @@
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
"auto_regulation_use_device_temp": "Use the eventual internal temperature sensor of the underlying to speedup the self-regulation",
|
||||
"inverse_switch_command": "For switch with pilot wire and diode you may need to inverse the command",
|
||||
"auto_fan_mode": " Automatically activate fan when huge heating/cooling is necessary"
|
||||
}
|
||||
@@ -297,6 +299,7 @@
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimal period",
|
||||
"auto_regulation_use_device_temp": "Use internal temperature of the underlying",
|
||||
"inverse_switch_command": "Inverse switch command",
|
||||
"auto_fan_mode": " Auto fan mode"
|
||||
},
|
||||
@@ -319,6 +322,7 @@
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
"auto_regulation_use_device_temp": "Use the eventual internal temperature sensor of the underlying to speedup the self-regulation",
|
||||
"inverse_switch_command": "For switch with pilot wire and diode you may need to invert the command",
|
||||
"auto_fan_mode": " Automatically activate fan when huge heating/cooling is necessary"
|
||||
}
|
||||
|
||||
@@ -36,6 +36,7 @@ from .const import (
|
||||
CONF_AUTO_REGULATION_EXPERT,
|
||||
CONF_AUTO_REGULATION_DTEMP,
|
||||
CONF_AUTO_REGULATION_PERIOD_MIN,
|
||||
CONF_AUTO_REGULATION_USE_DEVICE_TEMP,
|
||||
CONF_AUTO_FAN_MODE,
|
||||
CONF_AUTO_FAN_NONE,
|
||||
CONF_AUTO_FAN_LOW,
|
||||
@@ -90,6 +91,7 @@ class ThermostatOverClimate(BaseThermostat):
|
||||
"current_auto_fan_mode",
|
||||
"auto_activated_fan_mode",
|
||||
"auto_deactivated_fan_mode",
|
||||
"auto_regulation_use_device_temp",
|
||||
}
|
||||
)
|
||||
)
|
||||
@@ -192,8 +194,42 @@ class ThermostatOverClimate(BaseThermostat):
|
||||
|
||||
self._last_regulation_change = now
|
||||
for under in self._underlyings:
|
||||
# issue 348 - use device temperature if configured as offset
|
||||
offset_temp = 0
|
||||
device_temp = 0
|
||||
if (
|
||||
# regulation can use the device_temp
|
||||
self.auto_regulation_use_device_temp
|
||||
# and we have access to the device temp
|
||||
and (device_temp := under.underlying_current_temperature) is not None
|
||||
# and target is not reach (ie we need regulation)
|
||||
and (
|
||||
(
|
||||
self.hvac_mode == HVACMode.COOL
|
||||
and self.target_temperature < self.current_temperature
|
||||
)
|
||||
or (
|
||||
self.hvac_mode == HVACMode.HEAT
|
||||
and self.target_temperature > self.current_temperature
|
||||
)
|
||||
)
|
||||
):
|
||||
offset_temp = device_temp - self.current_temperature
|
||||
|
||||
target_temp = self.regulated_target_temp + offset_temp
|
||||
|
||||
_LOGGER.debug(
|
||||
"%s - The device offset temp for regulation is %.2f - internal temp is %.2f. New target is %.2f",
|
||||
self,
|
||||
offset_temp,
|
||||
device_temp,
|
||||
target_temp,
|
||||
)
|
||||
|
||||
await under.set_temperature(
|
||||
self.regulated_target_temp, self._attr_max_temp, self._attr_min_temp
|
||||
target_temp,
|
||||
self._attr_max_temp,
|
||||
self._attr_min_temp,
|
||||
)
|
||||
|
||||
async def _send_auto_fan_mode(self):
|
||||
@@ -284,6 +320,10 @@ class ThermostatOverClimate(BaseThermostat):
|
||||
else CONF_AUTO_FAN_NONE
|
||||
)
|
||||
|
||||
self._auto_regulation_use_device_temp = config_entry.get(
|
||||
CONF_AUTO_REGULATION_USE_DEVICE_TEMP, False
|
||||
)
|
||||
|
||||
def choose_auto_regulation_mode(self, auto_regulation_mode: str):
|
||||
"""Choose or change the regulation mode"""
|
||||
self._auto_regulation_mode = auto_regulation_mode
|
||||
@@ -492,6 +532,10 @@ class ThermostatOverClimate(BaseThermostat):
|
||||
"auto_deactivated_fan_mode"
|
||||
] = self._auto_deactivated_fan_mode
|
||||
|
||||
self._attr_extra_state_attributes[
|
||||
"auto_regulation_use_device_temp"
|
||||
] = self.auto_regulation_use_device_temp
|
||||
|
||||
self.async_write_ha_state()
|
||||
_LOGGER.debug(
|
||||
"%s - Calling update_custom_attributes: %s",
|
||||
@@ -770,6 +814,11 @@ class ThermostatOverClimate(BaseThermostat):
|
||||
"""Get the auto fan mode"""
|
||||
return self._auto_fan_mode
|
||||
|
||||
@property
|
||||
def auto_regulation_use_device_temp(self) -> bool | None:
|
||||
"""Returns the value of parameter auto_regulation_use_device_temp"""
|
||||
return self._auto_regulation_use_device_temp
|
||||
|
||||
@property
|
||||
def regulated_target_temp(self) -> float | None:
|
||||
"""Get the regulated target temperature"""
|
||||
|
||||
@@ -60,6 +60,7 @@
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimal period",
|
||||
"auto_regulation_use_device_temp": "Use internal temperature of the underlying",
|
||||
"inverse_switch_command": "Inverse switch command",
|
||||
"auto_fan_mode": " Auto fan mode"
|
||||
},
|
||||
@@ -82,6 +83,7 @@
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
"auto_regulation_use_device_temp": "Use the eventual internal temperature sensor of the underlying to speedup the self-regulation",
|
||||
"inverse_switch_command": "For switch with pilot wire and diode you may need to inverse the command",
|
||||
"auto_fan_mode": " Automatically activate fan when huge heating/cooling is necessary"
|
||||
}
|
||||
@@ -297,6 +299,7 @@
|
||||
"auto_regulation_mode": "Self-regulation",
|
||||
"auto_regulation_dtemp": "Regulation threshold",
|
||||
"auto_regulation_periode_min": "Regulation minimal period",
|
||||
"auto_regulation_use_device_temp": "Use internal temperature of the underlying",
|
||||
"inverse_switch_command": "Inverse switch command",
|
||||
"auto_fan_mode": " Auto fan mode"
|
||||
},
|
||||
@@ -319,6 +322,7 @@
|
||||
"auto_regulation_mode": "Auto adjustment of the target temperature",
|
||||
"auto_regulation_dtemp": "The threshold in ° (or % for valve) under which the temperature change will not be sent",
|
||||
"auto_regulation_periode_min": "Duration in minutes between two regulation update",
|
||||
"auto_regulation_use_device_temp": "Use the eventual internal temperature sensor of the underlying to speedup the self-regulation",
|
||||
"inverse_switch_command": "For switch with pilot wire and diode you may need to invert the command",
|
||||
"auto_fan_mode": " Automatically activate fan when huge heating/cooling is necessary"
|
||||
}
|
||||
|
||||
@@ -60,6 +60,7 @@
|
||||
"auto_regulation_mode": "Auto-régulation",
|
||||
"auto_regulation_dtemp": "Seuil de régulation",
|
||||
"auto_regulation_periode_min": "Période minimale de régulation",
|
||||
"auto_regulation_use_device_temp": "Utiliser la température interne du sous-jacent",
|
||||
"inverse_switch_command": "Inverser la commande",
|
||||
"auto_fan_mode": " Auto ventilation mode"
|
||||
},
|
||||
@@ -82,6 +83,7 @@
|
||||
"auto_regulation_mode": "Ajustement automatique de la température cible",
|
||||
"auto_regulation_dtemp": "Le seuil en ° (ou % pour les valves) en-dessous duquel la régulation ne sera pas envoyée",
|
||||
"auto_regulation_periode_min": "La durée en minutes entre deux mise à jour faites par la régulation",
|
||||
"auto_regulation_use_device_temp": "Utiliser la temperature interne du sous-jacent pour accélérer l'auto-régulation",
|
||||
"inverse_switch_command": "Inverse la commande du switch pour une installation avec fil pilote et diode",
|
||||
"auto_fan_mode": "Active la ventilation automatiquement en cas d'écart important"
|
||||
}
|
||||
@@ -309,6 +311,7 @@
|
||||
"auto_regulation_mode": "Auto-regulation",
|
||||
"auto_regulation_dtemp": "Seuil de régulation",
|
||||
"auto_regulation_periode_min": "Période minimale de régulation",
|
||||
"auto_regulation_use_device_temp": "Utiliser la température interne du sous-jacent",
|
||||
"inverse_switch_command": "Inverser la commande",
|
||||
"auto_fan_mode": " Auto fan mode"
|
||||
},
|
||||
@@ -331,6 +334,7 @@
|
||||
"auto_regulation_mode": "Ajustement automatique de la consigne",
|
||||
"auto_regulation_dtemp": "Le seuil en ° (ou % pour les valves) en-dessous duquel la régulation ne sera pas envoyée",
|
||||
"auto_regulation_periode_min": "La durée en minutes entre deux mise à jour faites par la régulation",
|
||||
"auto_regulation_use_device_temp": "Utiliser la temperature interne du sous-jacent pour accélérer l'auto-régulation",
|
||||
"inverse_switch_command": "Inverse la commande du switch pour une installation avec fil pilote et diode",
|
||||
"auto_fan_mode": "Active la ventilation automatiquement en cas d'écart important"
|
||||
}
|
||||
|
||||
@@ -580,6 +580,7 @@ class UnderlyingClimate(UnderlyingEntity):
|
||||
"""Set the target temperature"""
|
||||
if not self.is_initialized:
|
||||
return
|
||||
|
||||
data = {
|
||||
ATTR_ENTITY_ID: self._entity_id,
|
||||
"temperature": self.cap_sent_value(temperature),
|
||||
@@ -684,6 +685,18 @@ class UnderlyingClimate(UnderlyingEntity):
|
||||
return False
|
||||
return self._underlying_climate.is_aux_heat
|
||||
|
||||
@property
|
||||
def underlying_current_temperature(self) -> float | None:
|
||||
"""Get the underlying current_temperature if it exists
|
||||
and if initialized"""
|
||||
if not self.is_initialized:
|
||||
return None
|
||||
|
||||
if not hasattr(self._underlying_climate, "current_temperature"):
|
||||
return None
|
||||
|
||||
return self._underlying_climate.current_temperature
|
||||
|
||||
def turn_aux_heat_on(self) -> None:
|
||||
"""Turn auxiliary heater on."""
|
||||
if not self.is_initialized:
|
||||
|
||||
Reference in New Issue